Owner’s Manual SY-A2240L SY-A2480L SY-A4240L SY-A4480L PROTECT CH 1 CH 2 CH 3 CH 4 CLIP -20 dB SIGNAL POWER POWER AMPLIFIER ON OFF SY-A2240L PROTECT CH 1 CH 2 CH 3 CH 4 CLIP -20 dB SIGNAL POWER POWER AMPLIFIER ON OFF SY-A2480L PROTECT CH 1 CH 2 CH 3 CH 4 CLIP -20 dB SIGNAL POWER POWER AMPLIFIER ON OFF SY-A4240L PROTECT CH 1 CH 2 CH 3 CH 4 CLIP -20 dB SIGNAL POWER POWER AMPLIFIER ON OFF SY-A4480L
14
Embed
Owner’s Manual - etabeta-el.it · PDF fileowner’s manual sy-a2240l sy sy-a2480l po sy-a4240l po sy-a4480l po protect ch 1 ch 2 ch 3 ch 4 clip-20 db signal power power amplifier
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Owner’s Manual
SY-A2240L
SY-A2480L
SY-A4240L
SY-A4480L
PROTECT
CH 1 CH 2 CH 3 CH 4
CLIP
-20 dB
SIGNAL
POWER
POWER AMPLIFIER
ON
OFF
SY-A2240L
PROTECT
CH 1 CH 2 CH 3 CH 4
CLIP
-20 dB
SIGNAL
POWER
POWER AMPLIFIER
ON
OFF
SY-A2480L
PROTECT
CH 1 CH 2 CH 3 CH 4
CLIP
-20 dB
SIGNAL
POWER
POWER AMPLIFIER
ON
OFF
SY-A4240L
PROTECT
CH 1 CH 2 CH 3 CH 4
CLIP
-20 dB
SIGNAL
POWER
POWER AMPLIFIER
ON
OFF
SY-A4480L
WARNING
1
SY-A2240L / SY-A2480L / SY-A4240L / SY-A4480L
Introduction …………………………………………………………. 2
Features …………………………………………………................... 3
Front Panel Controls ………………………………………………… 4
Rear Panel Controls ………………………………………………… 5
Connecting the Amplifier............................................................6
The front panel of the SYA series slighly varies depending of the output configuration andpower rating, but basically the panel layout for all SYA amplifiers is similar.
1.Power switchA power switch allows to turn the amplifier on and off, while the blue indicator LEDlocated next to the button illuminates when the power is tumed on.
2.Indicator Led’sFour LED’s for every channel indicate the operation of the amplifier. The green SignalLED illuminates whenever a signal is present, while the -20dB LED illuminates when theinput signal exceeds the - 20 dBu level. The Clip LED illuminates when the correspondingchannel is working at maximum level. To ensure the best signal-to-noise ratio, the ClipLED may only illuminate at peak levels.
When the Clip LED illuminates frequently, the amplifier will be overloaded, a distorted“Clipping” sound will be available on the output. The Protection LED will illuminate whenoverheating occurs, or any other fault is detected. When the protection LED is illuminated,no signal will be available on the outputs. The protection LED’s will also illuminate for afew seconds when powering up the amplifier, and when the amplifier is switched off theywill slowly fade out.
PROTECT
CH 1 CH 2 CH 3 CH 4
CLIP
-20 dB
SIGNAL
POWER
POWER AMPLIFIER
ON
OFF
SY-A4480L
2 1
5
SY-A2240L / SY-A2480L / SY-A4240L / SY-A4480L
Rear Panel Controls
CH 4
SPEAKER OUTPUT
PUBLIC ADDRESS POWER AMPLIFIERSY-A4480L
-12 0dB
ADJUST
LINK
CH 2INPUT
OFF ON
HPF400Hz
-12 0dB
ADJUST
LINK
CH 3INPUT
OFF ON
HPF400Hz
-12 0dB
ADJUST
LINK
CH 1INPUT
OFF ON
HPF400Hz
DESIGNED AND ENGINEERED IN KOREA
WARNINGDO NOT EXPOSE
THIS EQUIPMENT TO RAIN OR MOISTURE
CAUTIONFOR CONTINUED
PROTECTION AGAINST RISK OF FIRE, REPLACE ONLY SAME TYPE FUSE
AVISRISQUE DE CHOC
ELECTRONIQUE NE PAS OUVRIR
ATTENTIONUTILISER UN FUSIBLE DE RECHANGE MEME
TYPE
CH 3
CH 2 CH 1
-12 0dB
ADJUST
LINK
CH 4INPUT
OFF ON
HPF400Hz
COM100 V
COM100 V
COM100 V
COM100 V
AC Input230V 50Hz, 2300WFUSE T12AH/250V
1 4 5
2 3
Rear Panel Controls
Rear panel descriptionThe rear panel of the SYA series slightly varies depending of the output configuration andpower rating, but basically the panel layout for all SYA amplifiers is similar. An XLR inputconnector with XLR link-through output connector, a high pass filter switch, a gain controlpotentiometer and an terminal block output connector are provided for every channel.
1.AC Power inlet with fuseThe mains power supply (230V AC / 50~60Hz) has to be applied to this AC powerinlet. The connection is made by an IEC power connector and is fitted with a fuse. Whenreplacing the fuse, make sure that the value of the replacement fuse matches the value ofthe original fuse. (SY-A2240L: T4AH/250V - SY-A2480L: T6.3AH/250V - SY-A4240L: T6.3AH/250V- SY-A4480L: T12AH/250V)
2.High pass filter switchBy means of this switch, the integrated High Pass Filter (HPF) can be switched ON andOFF. When the filter is switched ON, frequencies below 400Hz will be suppressed.This can be useful for eliminating low-frequency hum and noise caused by externalequipment and protects speakers from damage caused by excessive low frequencytransients.
3.Gain control potentiometerEach channel is fitted with a gain control knob whereby the level for each individualchannel can be adjusted.
4.Loudspeaker connectionsThe loudspeaker output connections are performed using 4-pin terminal blockconnectors, making it possible to connect high impedance (100V) loudspeakers to theamplifier outputs.
5.Input connectionsThe input connections of the amplifier are performed using balanced XLR connectors.Every channel has a XLR input connector and a XLR link output connector. The inputsignal from the signal source, pre-amplifier or mixer should be connected to the XLRinput connections. And by means of the XLR link output connectors, the signal can belinked through to multiple amplifiers.
6
SY-A2240L / SY-A2480L / SY-A4240L / SY-A4480LConnecting the Amplifier
Connecting the Amplifier
Input connections
The input connections of the amplifier are performed using balanced XLR connectors. Everychannel has a XLR input connector and a XLR link output connector.The input signal from the signal source, pre-amplifier or mixer should be connected to theXLR input connections. And by means of the XLR link output connectors, the signal can belinked through to multiple amplifiers.
-12 0dB
ADJUST
LINK
CH 1INPUT
OFF ON
HPF400Hz
CH 4
SPEAKER OUTPUT
CH 3
CH 2 CH 1
COM100 V
COM100 V
COM100 V
COM100 V
Output connections
The loudspeaker output connections are performed using 4-pin terminal blockconnectors, making it possible to connect high impedance (100V) loudspeakers to theamplifier outputs.
XLR Balanced Wiring Guide
7
SY-A2240L / SY-A2480L / SY-A4240L / SY-A4480L
Connecting the Amplifier
Connecting the Amplifier
The 100 Volt speakers may be connected in parallel on the outputs of the amplifierunless the maximum load / impedance has been reached. The number of allowableloadspeakers depends of the power / impedance of each connected loudspeaker.
CH 1
COM100 V
The table below shows the output voltage, impedance and maximum power load foreach corresponding amplifier.
Output Voltage Impedance Power
SY-A2240L 100 Volt 42 Ohm 240 Watt
SY-A2480L 100 Volt 21 Ohm 480 Watt
SY-A4240L 100 Volt 42 Ohm 240 Watt
SY-A4480L 100 Volt 21 Ohm 480 Watt
8
SY-A2240L / SY-A2480L / SY-A4240L / SY-A4480L
SY-A2240L SY-A2480L SY-A4240L SY-A4480L
Output Power(1 kHz, THD 1%)
2x240 Watt 2x480 Watt 2x240 Watt 2x480 Watt
Frequency Response (50Hz~18kHz) ±1dB
Signal to Noise Ratio > 90 dB
Total Harmonic Distortion + Noise < 0.3%
Common Mode Rejection > 70 dB
Crosstalk > 70 dB
Inputs
Type Balanced Line
ConnectorsFemale XLR Input
Male XLR Link Output
Impedance 10 k Ohm
Sensitivity 1 V RMS
Output
Type 100 V Loudspeaker Output
Connectors 4-pin Euro Terminal Block ~ 5.08 mm
Impedance 42 Ohm 21 Ohm 42 Ohm 21 Ohm
ControlsGain
High-Pass filter switch (400 Hz)
Indicators
Power
Protect
Peak
-20 dB
Signal
Protection
DC-Short Circuit
Over Heating
Over Load
Over Voltage
Cooling system Temperature controlled fan
Amplifier technology Class-D
Power supplyType Switching mode
Range 230 V AC / 50 Hz
Power consumption 1/8 Rated Power 115 Watt 187 Watt 218 Watt 440 Watt
Weight 7.2 Kg 7.5 Kg 8.35 Kg 8.85 Kg
Specifications