Top Banner
OVERFILL PREVENTION DEVICE Mechanism
12

OVERFILL PREVENTION DEVICE Mechanism. A. Where to place it ? 1 The OPD is compatible with all tanks equipped with manhole plates. The OPD has to be set.

Dec 18, 2015

Download

Documents

Ella Montgomery
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: OVERFILL PREVENTION DEVICE Mechanism. A. Where to place it ? 1 The OPD is compatible with all tanks equipped with manhole plates. The OPD has to be set.

OVERFILL PREVENTION DEVICE

Mechanism

Page 2: OVERFILL PREVENTION DEVICE Mechanism. A. Where to place it ? 1 The OPD is compatible with all tanks equipped with manhole plates. The OPD has to be set.

A. Where to place it ?

1

The OPD is compatible with all tanks equipped with manhole plates .

The OPD has to be set on the filling pipe inside the tank.

1

1

1

2

2

1 Manhole plate

Page 3: OVERFILL PREVENTION DEVICE Mechanism. A. Where to place it ? 1 The OPD is compatible with all tanks equipped with manhole plates. The OPD has to be set.

B. Technical characteristics

1

2

3

THE FLOAT

THE BALANCE WEIGHT

THE VALVE

1

3

2

5 THE PISTON5

4

6 THE CHAMBER

6

Red area = crossing liquid area

4 THE BALANCE SHAFT

Page 4: OVERFILL PREVENTION DEVICE Mechanism. A. Where to place it ? 1 The OPD is compatible with all tanks equipped with manhole plates. The OPD has to be set.

C. Mechanism

The 4 steps of the OPD mechanism:

1) THE FILLING STAGE

2) THE CLOSURE (level N1)

3) THE EMPTYING OF THE FLEXIBLE AND THE PIPE

4) THE CLOSURE (level Nmax)

Manhole plates

Valve

Nmax level

N1 level

Float

Low position

Balance shaft n°1

Balance shaft n°2

Balance Weight

Page 5: OVERFILL PREVENTION DEVICE Mechanism. A. Where to place it ? 1 The OPD is compatible with all tanks equipped with manhole plates. The OPD has to be set.

1) THE FILLING STAGE

The liquid flows through the OPD body (red area).

The float gradually rises according to the tank filling level.

The float is in low position and the piston in the high position.

C. Mechanism

Page 6: OVERFILL PREVENTION DEVICE Mechanism. A. Where to place it ? 1 The OPD is compatible with all tanks equipped with manhole plates. The OPD has to be set.

2) THE CLOSURE (level N1)

The balance Weights are carried along by the rise of the balance shaft on the float.

The piston partially obstructs the flow which enables the increase of the hydraulic pressure in the chamber.

C. Mechanism

Page 7: OVERFILL PREVENTION DEVICE Mechanism. A. Where to place it ? 1 The OPD is compatible with all tanks equipped with manhole plates. The OPD has to be set.

The hydraulic pressure let the Balance weights breaking away from the balance shaft. They finish their rise independently to the float while the piston sits on its seat.

The N1 level is reached and ensures a full closure.

2) THE CLOSURE (level N1)

C. Mechanism

Page 8: OVERFILL PREVENTION DEVICE Mechanism. A. Where to place it ? 1 The OPD is compatible with all tanks equipped with manhole plates. The OPD has to be set.

3) THE EMPTYING OF THE FLEXIBLE AND THE PIPE

The different steps of the emptying.

1) Closing the tanker truck valve.

2) Elimination of the hydraulic pressure in the chamber thanks to the flight hole pierced on the wrapping of the piston chamber and thanks to the opening valve.

3) Reopening of the piston

4) Emptying of the flexible (minimum 150 litters)

C. Mechanism

Page 9: OVERFILL PREVENTION DEVICE Mechanism. A. Where to place it ? 1 The OPD is compatible with all tanks equipped with manhole plates. The OPD has to be set.

4) LEVEL Nmax

In the event of accidental decanting, repeated emptying operations or failure to comply with the flows stipulated by current standards, the overfill prevention device can reach a maximum level Nmax which prevents any further filling until the liquid level has fallen in the tank.

C. Mechanism

Page 10: OVERFILL PREVENTION DEVICE Mechanism. A. Where to place it ? 1 The OPD is compatible with all tanks equipped with manhole plates. The OPD has to be set.

D. Technical characteristics HYDROCARBON OPD

Page 11: OVERFILL PREVENTION DEVICE Mechanism. A. Where to place it ? 1 The OPD is compatible with all tanks equipped with manhole plates. The OPD has to be set.

E. Conformity

All our OPD are certified ATEX (protection II Gc IIB T6), are complied with the 94/9/CE directive and with the European norm EN 13616.

Page 12: OVERFILL PREVENTION DEVICE Mechanism. A. Where to place it ? 1 The OPD is compatible with all tanks equipped with manhole plates. The OPD has to be set.

I am at your disposal for any further information.

Charles BROCHET

+33 (0)1 60 05 18 58

[email protected]