Top Banner
Outline: Fixation Disparity I Definitions & Purpose Retinal slip Micro Strabismus Closed-loop error Prevents decay of vergence II. Sign Convention III. Measurement with Nonius lines III. Factors influencing magnitude of FD Phoria Prism Lenses and Accommodative vergence IV. Provable test- Forced duction FD curve Prims induced Associated phoria slope relation to prism adaptation Lens induced V. V. Relation to AC/A ratio VI. VI. Vertical Fixation Disparity
26

Outline: Fixation Disparity I Definitions & Purpose ...schorlab.berkeley.edu/passpro/Lecture 5 slides.pdf1) Phoria Eso FD increases with Eso phoria Exo FD doesn’t increase with Exo

Oct 04, 2020

Download

Documents

dariahiddleston
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: Outline: Fixation Disparity I Definitions & Purpose ...schorlab.berkeley.edu/passpro/Lecture 5 slides.pdf1) Phoria Eso FD increases with Eso phoria Exo FD doesn’t increase with Exo

Outline:

Fixation Disparity I Definitions & Purpose

Retinal slip

Micro Strabismus

Closed-loop error

Prevents decay of vergence

II. Sign Convention

III. Measurement with Nonius lines

III. Factors influencing magnitude of FD

Phoria

Prism

Lenses and Accommodative vergence

IV. Provable test- Forced duction FD curve

Prims induced

Associated phoria

slope

relation to prism adaptation

Lens induced

V. V. Relation to AC/A ratio

VI. VI. Vertical Fixation Disparity

Page 2: Outline: Fixation Disparity I Definitions & Purpose ...schorlab.berkeley.edu/passpro/Lecture 5 slides.pdf1) Phoria Eso FD increases with Eso phoria Exo FD doesn’t increase with Exo

Four Maddox Components of Convergence

Tonic

Proximal

Fusional

Accommodative

Page 3: Outline: Fixation Disparity I Definitions & Purpose ...schorlab.berkeley.edu/passpro/Lecture 5 slides.pdf1) Phoria Eso FD increases with Eso phoria Exo FD doesn’t increase with Exo

Fusional vergence component is a buffer that takes up

the slack left by the other four components.

The “slack” or residual error of the sum of tonic,

proximal and accommodative vergence is measured as

the phoria.

Stress is assumed to be related to the amount of fusional

vergence effort under binocular viewing conditions.

Prism adaptation reduces the demand on fusional

vergence by increasing tonic vergence under binocular

viewing conditions.

Page 4: Outline: Fixation Disparity I Definitions & Purpose ...schorlab.berkeley.edu/passpro/Lecture 5 slides.pdf1) Phoria Eso FD increases with Eso phoria Exo FD doesn’t increase with Exo

Shortfall of the Maddox classification in the classical

case analysis:

The Maddox classification assumes that the phoria,

measured under monocular conditions, equals the

residual error under binocular viewing conditions.

Maddox does not consider prism adaptation, that

reduces the demand on fusional vergence under

binocular viewing conditions.

Page 5: Outline: Fixation Disparity I Definitions & Purpose ...schorlab.berkeley.edu/passpro/Lecture 5 slides.pdf1) Phoria Eso FD increases with Eso phoria Exo FD doesn’t increase with Exo

Instead of assuming the dissociated phoria equals the

demand on fusional vergence under binocular viewing

conditions, why not measure the stress on fusional

vergence directly under binocular viewing conditions?

How can we assess the demand under binocular

viewing conditions?

Fixation disparity is a small error under binocular

viewing conditions that is proportional to the demands

on fusional vergence.

Page 6: Outline: Fixation Disparity I Definitions & Purpose ...schorlab.berkeley.edu/passpro/Lecture 5 slides.pdf1) Phoria Eso FD increases with Eso phoria Exo FD doesn’t increase with Exo

Fixation Disparity is a steady-state error- Room

temperature thermostat analogy. Under binocular viewing

conditions, it keeps the eyes from drifting back to their

position of rest.

Fixation disparity increases when we fuse with the phasic

component of disparity vergence. It is analogous to

trying to heat a room with open windows.

Fixation disparity decreases when we fuse with adaptable

tonic vergence. This is analogous to heating a room with

sealed windows.

Page 7: Outline: Fixation Disparity I Definitions & Purpose ...schorlab.berkeley.edu/passpro/Lecture 5 slides.pdf1) Phoria Eso FD increases with Eso phoria Exo FD doesn’t increase with Exo

Fixation Disparity - Definition

• Fixation disparity is the difference between the

convergence angle under binocular viewing and the angle

subtended by the target at the centers of rotation

Fixation Disparity

Fixation Plane

Fixation Plane

Convergence

Point

ESO Fixation Disparity EXO Fixation Disparity

Page 8: Outline: Fixation Disparity I Definitions & Purpose ...schorlab.berkeley.edu/passpro/Lecture 5 slides.pdf1) Phoria Eso FD increases with Eso phoria Exo FD doesn’t increase with Exo
Page 9: Outline: Fixation Disparity I Definitions & Purpose ...schorlab.berkeley.edu/passpro/Lecture 5 slides.pdf1) Phoria Eso FD increases with Eso phoria Exo FD doesn’t increase with Exo

Fixation disparity: A small error in convergence or

eye alignment in the presence of feedback from

disparity.

Phoria A vergence error without fusion (i.e. when one

eye is occluded- i.e. open-loop or without feedback

from disparity). AKA dissociated phoria

Synonyms-

Retinal slip

Micro- strabismus

Page 10: Outline: Fixation Disparity I Definitions & Purpose ...schorlab.berkeley.edu/passpro/Lecture 5 slides.pdf1) Phoria Eso FD increases with Eso phoria Exo FD doesn’t increase with Exo

Sign Convention:

Eso (+) excessive convergence error

Exo (-) excessive divergence error

Units of measurement:

Minutes of arc.

Measurement tools using Nonius lines:Nonius lines are

a measure of Dichoptic Vernier Acuity

Mallett Unit- Measures the amount of prism needed to

reduce fixation disparity to zero (associated phoria)

Disparometer- Measures the fixation disparity directly.

Demonstrations:

Page 11: Outline: Fixation Disparity I Definitions & Purpose ...schorlab.berkeley.edu/passpro/Lecture 5 slides.pdf1) Phoria Eso FD increases with Eso phoria Exo FD doesn’t increase with Exo

Nonius lines are adjusted to lie on each fovea and their offset

indicates the small vergence error, i.e. Fixation Disparity

Page 12: Outline: Fixation Disparity I Definitions & Purpose ...schorlab.berkeley.edu/passpro/Lecture 5 slides.pdf1) Phoria Eso FD increases with Eso phoria Exo FD doesn’t increase with Exo

Factors that influence the magnitude of FD.

1) Phoria Eso FD increases with Eso phoria

Exo FD doesn’t increase with Exo phoria

1) Prisms (Base-out ∆ reduces Eso and increases Exo)

(Base-in ∆ reduces Exo and increases Eso)

2) Lenses (Plus lenses reduce Eso and increases Exo)

(Minus lenses reduce Exo and increase Eso)

Forced Duction (prism induced) Fixation Disparity Curve:

A provocative tests of prism adaptation.

Measure changes in fixation disparity with added prisms.

.

Page 13: Outline: Fixation Disparity I Definitions & Purpose ...schorlab.berkeley.edu/passpro/Lecture 5 slides.pdf1) Phoria Eso FD increases with Eso phoria Exo FD doesn’t increase with Exo

Phoria Status and Fixation Disparity

Three things are of interest to us…

1. The Y-intercept (Habitual FD)

2. The X-intercept (Associated Phoria)

3. The slope (∆∆∆∆y / ∆∆∆∆x)

Page 14: Outline: Fixation Disparity I Definitions & Purpose ...schorlab.berkeley.edu/passpro/Lecture 5 slides.pdf1) Phoria Eso FD increases with Eso phoria Exo FD doesn’t increase with Exo

Associated phoria- the amount of prism that reduces

fixation disparity to zero- good index of how

much prism to prescribe.

Dissociated phoria- the amount of prism that

reduces the phoria to zero under open-loop

conditions. Standard clinical phoria measure.

Page 15: Outline: Fixation Disparity I Definitions & Purpose ...schorlab.berkeley.edu/passpro/Lecture 5 slides.pdf1) Phoria Eso FD increases with Eso phoria Exo FD doesn’t increase with Exo

Four categories of forced duction Fixation Disparity Curves

Most common

Adapts well to

Base In prism

Adapts well to

base-out prism

Adapts

equally to

Base in and

out prism

Rare anomalous

response found in

strabismus

20%

75%

5%

Page 16: Outline: Fixation Disparity I Definitions & Purpose ...schorlab.berkeley.edu/passpro/Lecture 5 slides.pdf1) Phoria Eso FD increases with Eso phoria Exo FD doesn’t increase with Exo

Lens induced FD Prism induced FD

Plot lenses against prisms that produce the same fixation disparity

Estimate the AC/A

under binocular

conditions.

Page 17: Outline: Fixation Disparity I Definitions & Purpose ...schorlab.berkeley.edu/passpro/Lecture 5 slides.pdf1) Phoria Eso FD increases with Eso phoria Exo FD doesn’t increase with Exo

Vertical Fixation Disparity induced with vertical prism

Page 18: Outline: Fixation Disparity I Definitions & Purpose ...schorlab.berkeley.edu/passpro/Lecture 5 slides.pdf1) Phoria Eso FD increases with Eso phoria Exo FD doesn’t increase with Exo

Could there be Cyclo vergence fixation disparity?

Yes, but its not measured clinically.

Page 19: Outline: Fixation Disparity I Definitions & Purpose ...schorlab.berkeley.edu/passpro/Lecture 5 slides.pdf1) Phoria Eso FD increases with Eso phoria Exo FD doesn’t increase with Exo
Page 20: Outline: Fixation Disparity I Definitions & Purpose ...schorlab.berkeley.edu/passpro/Lecture 5 slides.pdf1) Phoria Eso FD increases with Eso phoria Exo FD doesn’t increase with Exo
Page 21: Outline: Fixation Disparity I Definitions & Purpose ...schorlab.berkeley.edu/passpro/Lecture 5 slides.pdf1) Phoria Eso FD increases with Eso phoria Exo FD doesn’t increase with Exo
Page 22: Outline: Fixation Disparity I Definitions & Purpose ...schorlab.berkeley.edu/passpro/Lecture 5 slides.pdf1) Phoria Eso FD increases with Eso phoria Exo FD doesn’t increase with Exo

Measuring Fixation Disparity

• Measured using Nonius lines

• View of right and left eyes’ separated using red-green goggles or polaroid goggles

• Patient makes qualitative judgment about whether the upper line is to the right or to the

left of the lower line

• The perceived location of the upper line is opposite to the deviation of the eye

Nonius

lines

Page 23: Outline: Fixation Disparity I Definitions & Purpose ...schorlab.berkeley.edu/passpro/Lecture 5 slides.pdf1) Phoria Eso FD increases with Eso phoria Exo FD doesn’t increase with Exo
Page 24: Outline: Fixation Disparity I Definitions & Purpose ...schorlab.berkeley.edu/passpro/Lecture 5 slides.pdf1) Phoria Eso FD increases with Eso phoria Exo FD doesn’t increase with Exo

Measuring Fixation Disparity

Mallett Unit

Demonstrate fixation

disparometer

Demonstrate fixation

disparity software

Page 25: Outline: Fixation Disparity I Definitions & Purpose ...schorlab.berkeley.edu/passpro/Lecture 5 slides.pdf1) Phoria Eso FD increases with Eso phoria Exo FD doesn’t increase with Exo

Prism induced fixation disparity curve

Page 26: Outline: Fixation Disparity I Definitions & Purpose ...schorlab.berkeley.edu/passpro/Lecture 5 slides.pdf1) Phoria Eso FD increases with Eso phoria Exo FD doesn’t increase with Exo