Outdoor Unit: 24-TON PUHY-P288TSLMU-A (-BS)(Consists of One PUHY-P120TLMU-A (-BS), One PUHY-P96TLMU-A (-BS), One PUHY-P72TLMU-A (-BS) and One CMY-Y300CBK2 Twinning Kit)
Operating Temperature Range *1 Cooling (Outdoor) *2 Refer to Module Data 23~126° F (-5~52° C) DB Heating (Outdoor) -13~60° F (-25~15.5° C) WB
External Dimensions (H x W x D) In. (mm) Refer to Module Data64-31/32 x 68-29/32 x
29-5/32(1,650 x 1,750 x 740)
64-31/32 x 48-1/16 x 29-5/32
(1,650 x 1,220 x 740)
64-31/32 x 36-1/4 x 29-5/32
(1,650 x 920 x 740)Net Weight Lbs. (kg) 1,605 (727) 671 (304) 499 (226) 435 (197)External Finish Refer to Module Data Pre-coated galvanized steel sheet
Electrical Power Requirements Voltage, Phase, Hertz Refer to Module Data** 208 / 230V, 3-Phase, 60Hz
Minimum Circuit Ampacity (MCA) A Refer to Module Data** 42 / 39 32 / 29 24 / 22
Maximum Overcurrent Protection (MOP) A Refer to Module
Data** 60 / 60 50 / 45 35 / 35
Piping Diameter (Brazed)From Twinning Kit to First Joint or Header (In. / mm)
Liquid (High Pressure) 3/4 (19.05) Refer to System DataGas (Low Pressure) 1-3/8 (34.93)Max. Total Refrigerant Line Length Ft. 3,280
Refer to System DataMax. Refrigerant Line Length (Between ODU & IDU) Ft. 541
Max. Control Wiring Length Ft. 1,640
Indoor UnitTotal Capacity 50~130% of outdoor
unit capacity Refer to System Data
Model / Quantity P06~P96/2~50 Refer to System DataSound Pressure Level dB(A) 64.0 Refer to System DataFanType x Quantity Refer to Module Data Propeller fan x 2 Propeller fan x 1 Propeller fan x 1Airflow Rate CFM 11,300 6,700 6,200External Static Pressure In. WG Refer to Module Data Selectable; 0, 0.12 or 0.24”WG; factory set to 0”W.G.Compressor Operating Range 4% to 100% Refer to System Data
Compressor Type x Quantity Refer to Module Data Inverter-driven Scroll Hermetic x 1
Inverter-driven Scroll Hermetic x 1
Inverter-driven Scroll Hermetic x 1
Refrigerant Refer to Module Data R410A; 26 lbs. + 1 oz. (11.8 kg)
R410A; 22 lbs. + 12 oz.
(10.3 kg)
R410A; 16 lbs. + 9 oz.
(7.5 kg)
Protection DevicesHigh Pressure
Refer to Module Data
High pressure sensor, High
pressure switch at 4.15 MPa (601 psi)
High pressure sensor, High
pressure switch at 4.15 MPa (601 psi)
High pressure sensor, High
pressure switch at 4.15 MPa (601 psi)
Inverter Circuit (Comp. / Fan)
Over-current protection
Over-current protection
Over-current protection
AHRI Ratings(Ducted/Non-Ducted)
EER 12.0 / 13.5Refer to System DataIEER 20.4 / 24.0
COP 3.47 / 3.70
UNIT OPTION □ Standard Model…...…...…………......………PUHY-P288TSLMU-A □ Seacoast (BS) Model…….....……......….PUHY-P288TSLMU-A-BS
ACCESSORIES □ Twinning Kit (required)...............................................…CMY-Y300CBK2 □ Joint Kit..............................for details see Pipe Accessories Submittal □ Low Ambient Kit ...............…..for details see Low Ambient Kit Submittal □ Snow/Hail Guards Kit......…for details see Snow/Hail Guards Kit Submittal □ Base Pan Heater Kit.............for details see Base Pan Heater Kit SubmittalOUTDOOR VRF HEAT PUMP SYSTEM
NOTES:*1. When applying product below -4° F, consult your design engineer for cold climate application best practices, including the use of a backup source for heating.*2. For details on extended cooling operation range down to -10° F DB, see Low Ambient Kit Submittal.
** Each individual module requires a separate electrical connection. Refer to electrical data for each individual module.
NOTES: SEACOAST PROTECTION • Anti-corrosion Protection: A coating treatment is applied to condenser coil for protection from air contaminants.• Standard: Salt Spray Test Method - no unusual rust development to 480 hours.• Sea Coast (BS): Salt Spray Test Method (JRA 9002) - no unusual rust development to 960 hours.
NOTES: SEACOAST PROTECTION • Anti-corrosion Protection: A coating treatment is applied to condenser coil for protection from air contaminants.• Standard: Salt Spray Test Method - no unusual rust development to 480 hours.• Sea Coast (BS): Salt Spray Test Method (JRA 9002) - no unusual rust development to 960 hours.
NOTES: SEACOAST PROTECTION • Anti-corrosion Protection: A coating treatment is applied to condenser coil for protection from air contaminants.• Standard: Salt Spray Test Method - no unusual rust development to 480 hours.• Sea Coast (BS): Salt Spray Test Method (JRA 9002) - no unusual rust development to 960 hours.
NOTES: SEACOAST PROTECTION • Anti-corrosion Protection: A coating treatment is applied to condenser coil for protection from air contaminants.• Standard: Salt Spray Test Method - no unusual rust development to 480 hours.• Sea Coast (BS): Salt Spray Test Method (JRA 9002) - no unusual rust development to 960 hours.
1340 Satellite Boulevard. Suwanee, GA 30024Toll Free: 800-433-4822 www.mehvac.com
Twinning Kit: CMY-Y300CBK2
The angle of the branch pipe for hign pressure is within against the horizontal plane. 2. Use the attached pipe to braze the port-opening of the distributer.3. Pipe diameter is indicated by inside diameter.4. Only use the Twinning pipe by Mitsubishi (optional parts) .
Note 1. Reference the attitude angle of the branch pipe below the fig.