Job Name:Schedule Reference: Date:
Specifications are subject to change without notice. © 2015 Mitsubishi Electric US, Inc.
Outdoor Unit: 16-TON PURY-HP192YSKMU-A(Consists of Two PURY-HP96YKMU-A and One CMY-R100CBK2 Twinning Kit)
OUTDOOR VRF HEAT PUMP WITH HEAT RECOVERY SYSTEM FEATURES• Innovative flash injection technology for tremendous heating
capacity at lower outdoor temperatures• Air-source, simultaneous cooling and heating• INVERTER-driven compressor• Connects to CITY MULTI indoor units• Controlled via CITY MULTI Controls Network
Specifications Model Name Module 1 Module 2Unit Type PURY-HP192YSKMU-A PURY-HP96YKMU-A PURY-HP96YKMU-A
Nominal Cooling Capacity(460V) Btu/h 192,000 96,000 96,000
Nominal Heating Capacity(460V) Btu/h 215,000 108,000 108,000
Operating Temperature Range *1Cooling (Outdoor) *2
Refer to Module Data23 ~ 115° F (-5 ~ +46° C) DB
Heating (Outdoor) -13 ~ +60°F (-25 ~ +15.5° C) WBExternal Dimensions (H x W x D) In. / mm Refer to Module Data 64-31/32 x 48-1/16 x 29-5/32 /
1,650 x 1,220 x 74064-31/32 x 48-1/16 x 29-5/32 /
1,650 x 1,220 x 740Net Weight Lbs. / kg 1152 / 522 576 / 261 576 / 261External finish Refer to Module Data** Pre-coated galvanized steel sheetElectrical Power Requirements Voltage, Phase, Hertz Refer to Module Data** 460V, 3-phase, 60HzMinimum Circuit Ampacity (MCA) A Refer to Module Data** 32** 32**Maximum Fuse Size A Refer to Module Data** 35** 35**Piping DiameterPiping Diameter (Brazed) (In. / mm)
Liquid (High Pressure) 7/8 / 22.2Refer to System Data
Gas (Low Pressure) 1-1/8 / 28.58
From Modules to Twinning Kit (Brazed) (In. / mm)
Liquid (High Pressure) Refer to Module Data 3/4 / 19.05 3/4 / 19.05Gas (Low Pressure) 7/8 / 22.2 7/8 / 22.2
Indoor UnitTotal Capacity 50 to 150% of ODUs
Refer to System DataModel / Quantity P06 ~ P96 / 1 to 48
Sound Pressure Levels dB(A) 61 58 58FanType x Quantity
Refer to Module DataPropeller Fan x 1 Propeller Fan x 1
Airflow Rate CFM 6200 6200
Compressor Operating RangeCooling: 12% to 100%;
Refer to System DataHeating: 6% to 100%
Compressor Type x Quantity Refer to Module Data Inverter-driven Scroll Hermetic x 1
Inverter-driven Scroll Hermetic x 1
RefrigerantRefer to Module Data
R410A x 26 lbs + 1 oz (11.8 kg)Lubricant MEL32
Protection DevicesHigh-pressure
Refer to Module Data
High pressure sensor, High pressure switch at 4.15 MPa
(601 psi)
High pressure sensor, High pressure switch at 4.15 MPa
(601 psi)Inverter circuit (COMP./FAN) Over-current protection Over-current protectionFan motor Thermal switch Thermal switch
AHRI Ratings (Ducted/Non-Ducted)
EER 11.1 / 12.1
Refer to System DataIEER 16.1 / 16.6COP 3.32 / 3.31
Simultaneous Rating (Ducted/Non-Ducted) SCHE *3 16.9 / 21.4
OPTIONAL PARTS □ Twinning Kit (required)..............................................…CMY-R100CBK2 □ Joint Kit.............................…for details see Pipe Accesories Submittal □ BC Controller.................…..............for details see BC Controller Submittals □ Low Ambient Kit ...............…..for details see Low Ambient Kit Submittal □ Snow/Hail Guards Kit......…for details see Snow/Hail Guards Kit Submittal □ Base Pan Heater Kit.............for details see Base Pan Heater Kit Submittal
NOTES:*1. Harsh weather environments may demand performance enhancing equipment. Ask your Mitsubishi Electric representative for more details about your region.*2. For details on extended cooling operation range down to -10° F DB, see Low Ambient Kit Submittal.
*3. Simultaneous Cooling and Heating Efficiency** Each individual module requires a separate electrical connection. Refer to electrical data for each individual module.
Page 2
Specifications are subject to change without notice. © 2015 Mitsubishi Electric US, Inc.
Outdoor Unit: PURY-HP192YSKMU-A – DIMENSIONSUnit: mm (in.)
2 - 257
2. EXTERNAL DIMENSIONSDATA U10
OUTDOOR UNITS
H2i
R2
PURY-HP144, 192YSKMU-A(-BS)Unit : mm(in)
Low pressure
Unit model
Component
unit model
ø15.88(5/8)ø19.05(3/4)
cc
ee
dd
ff
High pressure
69PH
27PH
Twinning Kit~O
utdoor unit
69PH
27PH
)5 eto
N()5
etoN(
--
ø19.05(3/4)ø19.05(3/4)
291P
H44
1PH
Low pressure
Twinning pipe connection size
Outdoor unit 1
Component unit nam
e
Package unit nam
e
BC controller~Twinning pipeab
High pressureO
utdoor Twinning K
it(optional parts)C
MY-R
100CB
K2
Outdoor unit 2
PURY-HP144YSKMU-A PURY-HP192YSKM
U-APURY-HP72YKM
U-A
PURY-HP96YKMU-A
PURY-HP72YKMU-A PURY-HP96YKM
U-A
ø28.58(1-1/8)ø22.2(7/8)
ø15.88(5/8)ø22.2(7/8)
Note 1. Connect the pipes as shown in the figure above. Refer to the table above for the pipe size.
2. Twinning pipe (High pressure) should not be tilted more than 15 degrees from
the horizontal plane.
Be sure to see the Installation Manual for details of Twinning pipe installation.
3. The pipe section before the Twinning pipe (section "a" in the figure) m
ust have at least 500mm
(19-11/16) of straight section
(*including the straight pipe that is supplied with the Twinning pipe).
4. Only use the Twinning pipe by M
itsubishi (optional parts).
5. Connect the outdoor unit 1 with the Twinning pipe (Low pressure) (section "d" in the figure).
30 (1-3/16))6
1/1-
84(
0221
)61/
1-84
( 02
21
1650 (64-31/32)
740 (29-5/32)
Front view
Left view
Outdoor unit 2
Outdoor unit 1
To BC controller
To BC controller
ab
e
fc
d
Twinning pipe(High pressure)<optional parts>
Twinning pipe(Low pressure)<optional parts>
Intakeair
Intakeair
Discharge air
Intakeair
Page 3
Specifications are subject to change without notice. © 2015 Mitsubishi Electric US, Inc.
Modules 1 and 2: PURY-HP96YKMU-A – DIMENSIONSUnit: mm (in.)
2 - 255
2. EXTERNAL DIMENSIONSDATA U10
OUTDOOR UNITS
H2i
R2
PURY-HP72, 96YKMU-A(-BS)Unit : mm(in)
(1)(1)
(3/4)(5/8)
(1-25/32)
(2-9/16)
(1-3/4)
(2-15/32)(7/8)
(1-3/8)
(1-11/32)
(2-1/16)
(3-23/32)(5-29/32)
(3-1/16)(5-17/32)
)1(
)1(
)4/3
((7/8)
Connecting pipe specifications
Note1. P
lease refer to the next page for information
regarding necessary spacing around the
unit and foundation w
ork.
2. At brazing of pipes, w
rap the refrigerant service valve
with w
et cloth and keep the temperature of
refrigerant service valve under 120°C
(248°F).
Refrigerant servicevalve <High pressure>
Refrigerant servicevalve <Low pressure>
Refrigerant service valve<Low pressure>Refrigerant service valve<High pressure>
(5-3/4)
(1-3/16)(1-3/16)
(29-5/32)(Mounting pitch)
(26-23/32~26-15/16)
(26-13/16)
(Mounting pitch)
)23/
5-3(
)23/
5-3(
(10-11/32)
(3-5/16)(3-23/32)
(10-23/32) 272(11-7/8) 301
(8-15/16) 227
(2-1/4)(2-1/4)
(13/16)(13/16)
(3-17/32) (3-1/16)
1
(9-29/32) 251(9-5/16) 236
(10-23/32) 272
(11-15/16)
(25/32)(25/32)
(2-25/32) =(5-29/32)X4(23-5/8)
<Snow hood attachment hole>
4X5-ø4.6 (3/16) Hole(M
ake hole at the plastic fan guard for snow hood attachm
ent)
Intakeair
Discharge air
Control box
Intakeair
Servicepanel
Intakeair<Sling hole>
36 2 4
58
2X2-14(9/16)X20(13/16) Oval hole
2X2-80(3-5/32)X35(1-13/32) Oval hole
7
*1 Use the pipe joint(field supply) and connect to the refrigerant service
valve piping.
Highpressure
ø25.4
Lowpressure
Service valveRefrigerant pipe
Diameter
*1
Highpressure
Lowpressure
Model
PURY-HP72YKMU-A
ø25.4ø19.05 Brazed
ø15.88 Brazed*1
ø45 Knockout hole
Specifications
ø43.7 or ø22.2 Knockout hole
ø62.7 or ø34.5 Knockout hole
Front through hole
Bottom through hole
Bottom through hole
Front through hole
Front through hole
For wires
UsageFront through hole
Front through hole(Uses when twinning kit (optional parts) is m
ounted.)
140 × 77 Knockout hole
150 × 94 Knockout holeBottom
through hole
For pipes
ø52 Knockout hole
For transmission cables
ø34 Knockout hole
ø65 Knockout hole
PURY-HP96YKMU-A
ø19.05 Brazed*1
ø25.4*1
ø25.4ø22.2 Brazed
Transformer box
58 (2-5/16)75 (2-31/32)
(8-9/16) 217(5-23/32) 145
146 (5-3/4)
146
83 (3-9/32)
262
(740)
150 (5-29/32)
57
54 (2-5/32)
19.5
801060 (41-3/4)
586 (23-3/32)
19.5
5794 84
121 (4-25/32) 600=150×4
20
1220 (48-1/16)
150 (5-29/32)
1650 (64-31/32)
196 (7-23/32)
1347 (53-1/16)
89
303
20
740 (29-5/32)
70
1181 (46-1/2)
140 (5-17/32)
80
77
681(678~684) 5.925.92
Bottom view
Left side viewFront view
Top view
NO.
12346 58 7
Page 4
Specifications are subject to change without notice. © 2015 Mitsubishi Electric US, Inc.
1340 Satellite BoulevardSuwanee, GA 30024Toll Free: 800-433-4822www.mehvac.com
FORM# PURY-HP192YSKMU-A - 201502
Twinning Kit: CMY-R100CBK2
Notes:
Ref: CMY_R100VBK_EXD_EUDB_SI
<Deformed pipe(Accessory)><Low-pressure pipe twinning kit(Accessory)>
High-pressure twinning pipe
Low-pressure pipe twinning kit
<Deformed pipe(Accessory)>
<Pipe for routing through the bottom (Accessory)>
<Pipe for routing through the front (Accessory)>
<Elbow pipe(Accessory)>
1"
3/4" 3/4"(Outside diameter)
1"
(Outside diameter)
(Outside diameter)
(3Pcs.)
(Outside diameter)
(Outside diameter)
(Outside diameter)
1”
1”
1”
7/8" 3/4"
5/8” 3/4”
3/4"
7/8”
1-5/32”
3/4” 7/8"
7/8" 7/8"
1-5/32"
1-5/32"
1-3/32”1”
21/3
2"
8-7/16” 4-17/32"
2-5/
16"
7-17/32"
3-5/32"
2-3/
8”
3-17
/32”
1-1/
4”
4-5/32”
2-15/32"
3-5/32"
1-13/3
2”
5-1/4”21/32”
6-15
/16”
17-1/32”
2-15/32"
1-7/1
6”
1-7/16”
1-31
/32"
1-31/32"
CMY-R100CBK2