Top Banner
Outcome 3 Electrical safety requirements Unit 201: Health and safety in building services engineering
8

Outcome 3 Electrical safety requirements Unit 201: Health and safety in building services engineering.

Dec 27, 2015

Download

Documents

Thomas Miles
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: Outcome 3 Electrical safety requirements Unit 201: Health and safety in building services engineering.

Outcome 3

Electrical safety requirements

Unit 201: Health and safety in building services engineering

Page 2: Outcome 3 Electrical safety requirements Unit 201: Health and safety in building services engineering.

Electrical supplyElectricity at Work Regulations

B7671

AC operating Voltage

Voltage colour

Use

25V Violet Damp conditions

50V White Damp conditions

110V Yellow General site voltage

230V Blue Domestic and site offices

400V Red Fixed machinery

Page 3: Outcome 3 Electrical safety requirements Unit 201: Health and safety in building services engineering.

Site electricity• Battery operated• 110v single phase ac (site)• 230v single phase ac can • Use a step-down transformer.

Page 4: Outcome 3 Electrical safety requirements Unit 201: Health and safety in building services engineering.

Electrical hazards

City and Guilds 6035 Level 2 Unit 201

Beware of hidden conduit

in brickwork

Beware of melting cable with heated

tube

Beware of chafing cable

Beware of storing cable

correctly

Beware of damage to power tool

casing

Beware of hidden cables in walls and

floors

Beware of cables when

soldering

Beware of exposed wires

Page 5: Outcome 3 Electrical safety requirements Unit 201: Health and safety in building services engineering.

Electrical hazards• Faulty installations• Faulty equipment• Misuse• Trailing, buried, hidden – or cables too close to pipework• Incorrect fuse• Overloading sockets• Neglect• Wet conditions.

Page 6: Outcome 3 Electrical safety requirements Unit 201: Health and safety in building services engineering.

Electrical checksVisually inspect:• Cables• Casing• Lead condition• Length of leads• Use a cable finder• Take care when lifting floorboards• Report to supervisor• PAT test label• Double insulated • RCD for 230v.

Page 7: Outcome 3 Electrical safety requirements Unit 201: Health and safety in building services engineering.

Electrical safe isolationAll electrical circuits must be properly switched off, isolated, labelled, locked off and proven dead.

• Identify circuit or appliance• Check with customer before isolating• Select voltage indicator and test• Prove circuit is live• Pull fuse or switch off MCB• Lock and label• Prove circuit is dead• Test voltage indicator• Start work.

Page 8: Outcome 3 Electrical safety requirements Unit 201: Health and safety in building services engineering.

Electrical safety• Whenever you cut or remove a section of pipe always

use temporary continuity bonds• Two crocodile clips joined with 10mm2 earth cable.

When used, these prevent electric shocks if there is a fault.