This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1 of 13 (Rev. 09/2020) ORY4S_ss_v6.3
In a continuing effort to offer the best product possible, we reserve the right to change, without notice, specifications or materials that in our opinion will not alter the function of the product. Specification sheets found at www.selux.us are the most recent versions and supercede all other printed or electronic versions.
Series Optics Mounting OptionsFixture # Light Engine
-
Rivnut Pairs
RN - - - - - - - -
Fixture #
CCT Finish Voltage
* Refer to chart on page 4 for Rivnut locations*Rivnut Locations
- -
- - - - -- - -
- - - - -- - -
- - - - -- - -
Project:
Type: Qty:
Date: Customer:
LED WARRANTY
5YEARBUY
AMERICAN
Series U4 Ouray 400
Optics
U4
Fixed Mounting
SBx Short Pole BracketSistema Mount
SQx Square Pole Bracket Sistema Mount
*May be combined with adjustable mounting
R1 Type I
R2 Type II
R3 Type III
R5R Type V (Round)
R4 Type IV
R5S Type V (Square)
PP Plane Projector
R3W Type III (Wide)
R5Q Type V (Rectangular)
Light Engine 5G350 19W/2,012lm
5G530 28W/2,935lm
5G700 39W/3,722lm
CCT
Adjustable Mounting
Finish WH White
BK Black
BZ Bronze
SP Specify Premium Color
Voltage UNV
Options
3 2700K and 3000K are IDA- Approved
* For other CCT, please consult factory
SV Silver
303 3000K
40 4000K
8 120V, 240V or 277V only
7 120V or 277V only
6 DM, HLXX, TLR or IMS only. Cannot be combined.
5 Type I, II, III, and IV only
9 Glass is included with CO and PP options and does not need to be specified separately
5G105 58W/5,169lm
5G1402 75W/6,120lm
BL Semi-Matte Black
120- 277
HS5 House Side Shield (180°)
DM6 Dimming (0-10V)
GL9 Tempered Glass Lens
TLR6,8 Twist Lock Receptacle 7-Pin with Shorting Cap
HL306,8 Hi-Lo Switching Low Output 30%
HL506,8 Hi-Lo Switching Low Output 50%
AT1 Adjustable Tilt
AS Adjustable Swivel
XX None
1204 120V
2404 240V
2774
277V347 347V
480 480V
4Specify for HLXX option
Pole Motion Sensor with optional photocell See page 11 for order code
2 347/480V and HLXX options cannot be combined with 5G140
* Based on RI distributions at 3000K CCT no glass
Power Cord Length
8 10 12 14 16 18 XX 8’ 10’ 12’ 14’ 16’ 18’ XX’
CO9 Comfort Optics (Not available with PP optics)
* Add length of arm and height of pole to determine power cord length
TLRP8 Twist Lock Receptacle3-Pin with Photocell
IMS6,7
Internal Motion Sensor
273 2700K
1 AT mounting not IDA approved
* Refer to page 4 for locating mountings
Page 2 of 13 (Rev. 09/2020) ORY4S_ss_v6.3
In a continuing effort to offer the best product possible, we reserve the right to change, without notice, specifications or materials that in our opinion will not alter the function of the product. Specification sheets found at www.selux.us are the most recent versions and supercede all other printed or electronic versions.
1. Fixture Housing - Die cast low copper marine grade aluminum body and door. Optional tempered glass lens.
2. Gasketing - Continuous molded silicone gasket provides weatherproofing, dust and insect control at all luminaire connections.
3. Access Door - Die cast low-copper marine grade aluminum door. Hinges open for tooless access to LED light engine and is retained in place with fixed hinge.
4. LED Array - High Flux LEDs mounted to metal core PCB and attached to external heat sink for maximum LED performance and life. CCT tolerance within a 3-step bin and provided with a minimum CRI of 80. LED array has a reported lumen maintenance of 93% at 50,000 hours. L70 calculated greater than 100,000 hours. Exposed face rated to IP65.
5. LED Optics - Technical Optics (R1, R2, R3, R3W, R4, R5S, R5Q, and R5R) use Selux signature light pattern acrylic lens holder to secure proprietary silicone optics. Internal micro house side shield available for distributions types I, II, III and IV. Plane Projector (PP) optics available for up lighting. Comfort Optics (CO) option provided with fully diffuse glass.
6. LED Driver - LEDs are driven by RoHS compliant constant current programmable LED driver. Driver includes 0-10V dimming to 10%, meets the requirements of IP66. Driver assembly located inside the head and accessible through the hinged door. 7. Surge Protection - 3-Pole Surge Protection device safeguards electrical components from indirect lighting strikes and surges up to (20kA standard). RoHS compliant.
Exterior Luminaire Finish -Selux utilizes a high quality Polyester Powder Coating. All Selux luminaires and poles are finished in our Tiger Drylac certified facility and undergo a five stage intensive pretreatmentprocess where product is thoroughly cleaned, phosphated and sealed. Selux powder coated products provide excellent salt and humidity resistance as well as ultra violet resistance for color retention. All products are tested in accordance with test specifications for coatings from ASTM and PCI.
Standard exterior colors are White (WH), Black (BK), Semi-Matte Black (BL), Bronze (BZ), and Silver (SV). Selux premium colors (SP) are available, please specify from your Selux color selection guide. Hot Dip Galvanized finish (GV) on all steel parts also available.
5 Year Limited LED Luminaire Warranty - Selux offers a 5 Year Limited Warranty to the original purchaser that Ouray LED luminaire shall be free from defects in material and workmanship for up to five (5) years from date of shipment. This limited warranty covers the fixture, LED driver and LED light engine when installed and operated according to Selux instructions. Fixture suitable for ambient temperatures of 45ºC (113ºF). For details and exclusions, see “Selux Terms and Condition of Sale.”
Listings and Ratings: Tested to IESNA LM-79-08 and LM-80 test standards at 25ºC ambient temperature. Rated for wet location.
Visit selux.us for our LED End of Life recycling policy.
Specifications
U4
16 1/4” (413mm)
9 1/16” (230mm)
3 1/4” (82mm)
1
45 2
For Buy American compliance on poles, please consult the factory.
Page 3 of 13 (Rev. 09/2020) ORY4S_ss_v6.3
In a continuing effort to offer the best product possible, we reserve the right to change, without notice, specifications or materials that in our opinion will not alter the function of the product. Specification sheets found at www.selux.us are the most recent versions and supercede all other printed or electronic versions.
Adjustable arm located between fixture head and fixed mounting.
Swivel +/- 90° in 2.5° increments
AT Adjustable Tilt
AS Adjustable Swivel
EPA = 0.1ft2 (0.01m2)
Weight = 2.5lbs. (1.1kg)AT/AS mounting only - Add to primary mounting values.
EPA = 0.1ft2 (0.01m2)
Weight = 2.5lbs. (1.1kg)AT/AS mounting only - Add to primary mounting values.
EPA = 0.4ft2 (0.04m2)
Weight = 15lbs. (7kg)
EPA = 0.4ft2 (0.04m2)
Weight = 15lbs. (7kg).
Page 4 of 13 (Rev. 09/2020) ORY4S_ss_v6.3
In a continuing effort to offer the best product possible, we reserve the right to change, without notice, specifications or materials that in our opinion will not alter the function of the product. Specification sheets found at www.selux.us are the most recent versions and supercede all other printed or electronic versions.
Use checkboxes provided in chart below. Columns #0 through #9 indicate heights starting with 3" (76mm) + 9" (229 mm) below top of pole and proceeding downwards in increments of 12 inches (305mm). Rows A,G,M, and S indicate angular placement around pole starting with 0° at handhole and proceeding clockwise.
ANGULAR LOCATION CODE
CLOCKWISE FROM HANDHOLE
DISTANCE FROM TOP OF POLE
HEIGHT CODE NOTE: Arms mounted at same height level must be spaced apart at 180º, unless AT or AS mounting is specified.
(Luminaire shown for illustrative purposes only - not to scale)
(NOTE: If using Adobe Acrobat to enter data (checks) in chart on right, the following instructions will be carried out aut automatically)
When specifying non-standard configurations, enter “SB/SQ + total number of arms specified)” on con-figuration matrix on page 1 in the fixture mounting field. Example: SS4 (specifying 4 mounting arms)
Build up the Mounting Arm Location Codes from chart on right (“Height Code” + “Angular Location Code”) i.e. “4G”= 4 feet from top of pole, 90º clockwise from handhole.
Enter Mounting Arm Location Codes on page 1 in the blanks provided that follow the Pole Option blanks. Example: 0A-2G-0M-2S
In a continuing effort to offer the best product possible, we reserve the right to change, without notice, specifications or materials that in our opinion will not alter the function of the product. Specification sheets found at www.selux.us are the most recent versions and supercede all other printed or electronic versions.
Pole InformationRefer to pole specification sheets for construction details, anchorage information and additional options.
A35Round Straight Aluminum Pole
AT535 / AT64 Tapered Aluminum Pole
A40Round Straight Aluminum Pole
BC5 Decorative Cast Aluminum Base Cover (A35 Pole Only) Die cast aluminum, two-piece field installable base cover.
BC9 Optional Base Cover (AT64) Die cast aluminum, two-piece field installable base cover.
Ø3.5” (90mm)
5 1/4”
81/8” (205mm)
Ø203/8” (518mm)
Ø12 7/16” (316mm)
Ø6” (152mm)
BC13 Optional Base Cover (A40) Die cast aluminum, two-piece field installable base cover.
Ø12 7/16” (316mm)
5 3/16” (133mm)
Ø4” (102mm)
18” (457mm)
Pole Data Chart
Allowable EPA calculated according to AASHTO 1994 and include allowance for 1/3 gust factor. See Mounting Configuration pages for fixture arm weight and EPA values.
U-AT535 5" to 3.5" Round tapered Aluminium Pole 8 5/8" 9.1 6.9 5.4 4.3 3.4 2.9 2.4 2.0 1.7 1.5
U-AT64 6" to 4" Round tapered Aluminium Pole 9 1/2" 14.3 11.2 9.0 7.4 6.2 5.2 4.4 3.8 3.3 2.9
26” (660mm)
Pole
Hei
gh
t
18” (457mm)
BC3 Optional Base Cover (AT535) Die cast aluminum, two-piece field installable base cover.
Ø5” (127mm)
5 3/16” (131mm)
Ø12 7/16” (316mm)
Pole width3.5"(90mm)
Pole width4"(102mm)
Page 6 of 13 (Rev. 09/2020) ORY4S_ss_v6.3
In a continuing effort to offer the best product possible, we reserve the right to change, without notice, specifications or materials that in our opinion will not alter the function of the product. Specification sheets found at www.selux.us are the most recent versions and supercede all other printed or electronic versions.
BOLT CIRCLE DETAIL (Not to Scale)USE CAUTION WHEN SETTING ANCHOR BOLTS. BOLTS MUST BE VERTICALLY STRAIGHT AND CENTERED ON DIMENSIONS SHOWN.
Bolt Circle for A35 & S35 Use caution when setting anchor bolts. Bolts must be vertically straight and centered on dimensions shown
Note: Adequate drainage must be provided in concrete foundation.
Anchor Bolt Detail for A35 & S35
3 1/4” (83mm)
3/4” x 17” Partially g alvanized Anchor Bolts
3/4” -10 Galvanized Heavy Hex Nut
3/4” (19mm) ID Galvanized Flat Washers
Concrete footing designed and supplied by others
1/2” (13mm) for leveling
3/4” - 10 Galvanized Heavy Hex Leveling Nut
Bolt Circle for A40 Use caution when setting anchor bolts. Bolts must be vertically straight and centered on dimensions shown
A40 POLE ONLY
Hand Hole Location
8 15/16”(227mm)
Ø7 1/2” (191mm) Bolt Circle
Ø3 3/4” (95mm) Conduit Opening
Note: Adequate drainage must be provided in concrete foundation.
5 5/16”(135mm)
3 1/4
" [8
2mm
]
1/2" [13mm]FOR LEVELING
3/4-10 UNC X 17" PARTIALLYGALVANIZED ANCHOR BOLT
3/4-10 UNC GALVANIZED HEAVY HEX NUT
3/4 I.D. GALVANIZEDFLAT WASHER
3/4-10 UNC GALVANIZEDHEAVY HEX LEVELING NUT
CONCRETE
3/4” -10 UNC x 17" Partially Galvanized Anchor Bolt
3/4” ID Galvanized Flat Washers
Concrete footing designed and supplied by others
3/4” -10 Galvanized Heavy Hex Nut
3/4” -10 UNC Galvanized Hex Leveling Nut
3 1/4” (83mm
1/2” (13mm) for leveling
Anchor Bolt Detail for A40
Ă4 1/2" [Ă114mm]
9 5/8" [244mm] SQUARE
Ă8 5/8" [Ă219mm]
6 1/8" [155mm]
CONDUIT OPENING
BOLT CIRCLE
HANDHOLE SIDE OF POLE.
Bolt Circle for AT535 Use caution when setting anchor bolts. Bolts must be vertically straight and centered on dimensions shown
Anchor Bolt Detail for AT535
Hand Hole Location
9 5/8” (244mm)
Ø8 5/8” (219mm) Bolt Circle
Ø4 1/2” (114mm) Conduit Opening
6 1/8” (155mm)
3 1/4
" [8
2mm
]
1/2" [13mm]FOR LEVELING
3/4-10 UNC X 17" PARTIALLYGALVANIZED ANCHOR BOLT
3/4-10 UNC GALVANIZED HEAVY HEX NUT
3/4 I.D. GALVANIZEDFLAT WASHER
3/4-10 UNC GALVANIZEDHEAVY HEX LEVELING NUT
CONCRETE
3 1/4” (82mm)
3/4” -10 Galvanized Heavy Hex Nut3/4” ID Galvanized Flat Washers
Concrete footing designed and supplied by others
1/2” (13mm) for leveling
3/4” - 10 Galvanized Heavy Hex Leveling Nut
3/4” -10 x 17" Partially Galvanized Heavy Hex Nut
6 3/4" [172mm]
10 5/16" [262mm] SQUARE
Ă5 1/2" [Ă140mm]
Ă9 1/2" [Ă241mm]
CONDUIT OPENING
BOLT CIRCLE
HANDHOLE SIDE OF POLE.
Bolt Circle for AT64 Use caution when setting anchor bolts. Bolts must be vertically straight and centered on dimensions shown
Anchor Bolt Detail for AT64
Hand Hole Location
10 5/16” (262mm) Square
Ø9 1/2” (241mm) Bolt Circle
Ø5 1/2” (140mm) Conduit Opening
6 3/4” (172mm)
3 1/2
" [8
9mm
]
1/2" [13mm]FOR LEVELING
3/4-10 UNC X 17" PARTIALLYGALVANIZED ANCHOR BOLT
3/4-10 UNC GALVANIZED HEAVY HEX NUT
3/4 I.D. GALVANIZEDFLAT WASHER
CONCRETE
3/4-10 UNC GALVANIZEDHEAVY HEX LEVELING NUT
3 1/2” (89mm)
3/4” -10 Galvanized Heavy Hex Nut
3/4” ID Galvanized Flat Washers
Concrete footing designed and supplied by others
1/2” (13mm) for leveling
3/4” - 10 Galvanized Heavy Hex Leveling Nut
3/4”-10 x 17" Partially Galvanized Heavy Hex Nut
A35/S35 POLE ONLY
Hand Hold Location
Ø7 3/4” (197mm) Bolt Circle
Ø3” (76mm) Conduit Opening
8” (203mm)
5 5/16”(135mm)
Page 7 of 13 (Rev. 09/2020) ORY4S_ss_v6.3
In a continuing effort to offer the best product possible, we reserve the right to change, without notice, specifications or materials that in our opinion will not alter the function of the product. Specification sheets found at www.selux.us are the most recent versions and supercede all other printed or electronic versions.
Pole Information Square Pole Anchor Bolt Template Use caution when setting anchor bolts. Bolts must be vertically straight and centered on dimensions shown.
12” (305mm)
4” (102mm)
Pole Data Chart (For "SQ" mounting only)
Base Cover (BC)Optional Base Cover
(U-AQ40)
Ouray 400 Sistema
U-AQ40Square Aluminum Pole
OPTIONAL BASE COVER
OVERALL HEIGHT
9 3/4" [249mm]
13” (330mm)
Square
OPTIONAL BASE COVER
OVERALL HEIGHT
9 3/4" [249mm]
6 1/2” (165mm)
4” (101.6mm)
OPTIONAL BASE COVER
OVERALL HEIGHT
9 3/4" [249mm]
13” (330mm)
Square
OPTIONAL BASE COVER
OVERALL HEIGHT
9 3/4" [249mm]
6 1/2” (165mm)
5” (127mm)
OPTIONAL BASE COVER
OVERALL HEIGHT
9 3/4" [249mm]
14.5” (330mm)
Square
OPTIONAL BASE COVER
OVERALL HEIGHT
9 3/4" [249mm]
7 1/2” (184mm)
6” (152.4mm)
Optional Base Cover(U-AQ50)
Optional Base Cover(U-AQ60)
3 1/8” (79mm)
1/2” (13mm)
for leveling
3/4-10 UNC x 17" partially galvanized anchor bolt
3/4-10 UNC galvanized heavy hex nut
3/4 I.D. galvanized flat washer
3/4-10 UNC galvanized heavy hex leveling nut
Concrete
3/4-10 UNC x 17" partially galvanized anchor bolt
3/4-10 UNC galvanized heavy hex nut
3/4 I.D. galvanized flat washer
3/4-10 UNC galvanized heavy hex leveling nut
Concrete
3 1/4” (82mm)
1/2” (13mm)
for leveling
1"-8 UNC x 36" partially galvanized anchor bolt1"-8 UNC x 17' galvanized heavy hex nut
1" I.D. galvanized flat washer
1"-8 UNC galvanized heavy hex leveling nut
Concrete
3 1/4” (82mm)
1/2” (13mm)
for leveling
Page 8 of 13 (Rev. 09/2020) ORY4S_ss_v6.3
In a continuing effort to offer the best product possible, we reserve the right to change, without notice, specifications or materials that in our opinion will not alter the function of the product. Specification sheets found at www.selux.us are the most recent versions and supercede all other printed or electronic versions.
Hi-Lo Switching Option (HL30/HL50) Wiring120/240/277V. When red is energized, light output will beat "Lo" level.
SURGEPROTECTOR
BLACK
WHITE
BARE
ORANGE
RED
L1
N
SPARE
L2
FROMFEEDCORD
RELAY
DRIVER(S) /LIGHT ENGINE
CAPPEDINSIDE
FIXTURE
* (347/480V with 5G350 has a transformer - not shown)
Page 9 of 13 (Rev. 09/2020) ORY4S_ss_v6.3
In a continuing effort to offer the best product possible, we reserve the right to change, without notice, specifications or materials that in our opinion will not alter the function of the product. Specification sheets found at www.selux.us are the most recent versions and supercede all other printed or electronic versions.
GFCI Receptacle (REC) - 120V 15A GFCI duplex receptacle with weatherproof, self-closing cover; located 36” (915mm) o.c from base of pole, in-line with hand hole. Receptacle is intended only for portable tools or other portable equipment to be connected to outlet only when attended by operating personnel (120V only).
GFCI Receptacle (REC2) - 120V 15A GFCI duplex receptacle with weatherproof, self-closing, padlockable in-use cover; located 36” (915mm) o.c. from base of pole, in-line with hand hole. Receptacle is intended only for portable tools or other portable equipment to be connected to outlet only when attended by operating personnel (120V only).
USB & Duplex Receptacle (REC3) (not shown) - 120V 20A duplex receptacle with USB combination ports. (1) type A and (1) type C high power 5A, 5V USB outlets. With weatherproof, self-closing cover; located 36” (915mm) o.c from base of pole, in-line with hand hole. Receptacle is intended only for portable tools or other portable equipment to be connected to outlet only when attended by operating personnel.
REC3 does not incorporate GFCI (Ground Fault Circuit Interrupter) protection, and shall be powered by a GFCI protected branch circuit (by others).
USB & Duplex Receptacle (REC4) (not shown)- 120V 20A duplex receptacle with USB combination ports. (1) type A and (1) type C high power 5A, 5V USB outlets. With weatherproof, self-closing padlockable in-use cover; located 36” (915mm) o.c from base of pole, in-line with hand hole. Receptacle is intended only for portable tools or other portable equipment to be connected to outlet only when attended by operating personnel.
REC4 does not incorporate GFCI (Ground Fault Circuit Interrupter) protection, and shall be powered by a GFCI protected branch circuit (by others).
Page 10 of 13 (Rev. 09/2020) ORY4S_ss_v6.3
In a continuing effort to offer the best product possible, we reserve the right to change, without notice, specifications or materials that in our opinion will not alter the function of the product. Specification sheets found at www.selux.us are the most recent versions and supercede all other printed or electronic versions.
SENSOR ANGULAR ORIENTATION FROM HAND HOLE 0°IN 90° INCREMENTS CLOCKWISE AROUND POLE (TYPE 00,09,18,27)
General Pole Drawing For Example Only
TYPE 27 (270°)
TYPE 18 (180°)
TYPE 09 (90°)
HAND HOLELOCATIONTYPE 00 (0°)
TOP VIEW
SENSOR ANGULAR ORIENTATION FROM HAND HOLE 0°90° INCREMENTS CLOCKWISE AROUND POLE (TYPE 00,09,18,27)
Sensor angular orientation from hand hole 0°
90° increments clockwise around pole (Type 00,09,18,27)
OverallPole
Height
DREV.
DWG SIZE
TYPE 27 (270Ā)
TYPE 18 (180Ā)
TYPE 09 (90Ā)
HAND HOLDLOCATION
TYPE 00 (0Ā)
TOP VIEW
SENSOR ANGULAR ORIENTATION FROM HAND HOLE 0ĀIN 90Ā INCREMENTS CLOCKWISE AROUND POLE (TYPE 00,09,18,27)
POLE DEPICTED IS GENERIC PLEASEREFERENCE CUSTOMER ORDER
FOR SPECIFIC POLE MODEL NUMBERTYPE 18 SHOWN
SCALE: 1:16
ADRAWN BY: FAH
DRW
JLJ
REVISIONSREV. ECN DESCRIPTION DATE BY APPR BY
01 XXXX CREATED FOR MARKETING 09/21/2016 FAH DRW
A 0017.17TO DETAIL MODIFICATION TOPOLES AND COLUMNS FOR
SENSOR MOUNTING ORIENTATIONLOGIC
07/12/2017 FAH DRW
12"305.00
NOMINALPOLE
HEIGHTMINUS 12"
NOMINALPOLE HEIGHT
HAND HOLELOCATIONA
4 X Ă .136 3.45 THRU8-32 UNC THRU
2 X Ă .188 4.76 THRU
2.00050.80
3.00076.20
1.00025.40
.50012.70
3.50088.90
3.25082.55
1.62541.28
1.75044.45
1.00025.40
DETAIL ASCALE 1 : 1
MATERIAL: SEE BOM
PRODUCT SERIES:
R
THIS DRAWING IS THE PROPERTY OF SELUX CORPORATION AND ISPROTECTED BY COPYRIGHT LAW. IT MAY ONLY BE COPIED ORREPRODUCED WITH PRIOR, WRITTEN AUTHORIZATION FOR THEPURPOSE OF MANUFACTURING AND/OR SUBMISSION FOR SELUXCORPORATION.
DWG. #: 6-48B323-00FINISH: PER SO
EXTERIOR SENSOR POLE MOD REFERENCE
T (845) 691-7723F (845) 691-6749
DATE: 9/21/2016
SHEET:1 OF 2
TOLERANCES UNLESS OTHERWISE NOTED:DECIMAL INCH:
.XX ā .02"
.XXX ā .010"
DECIMAL METRIC:
X.X ā .5X.XX ā .25
FRACTIONS: ā 1/32 [.79mm] ANGULAR: ā 1 1/2 Ā
5 LUMEN LANEP.O. BOX 1060HIGHLAND, NY 12528
CHECKED BY:
APPROVED BY:
ES01
A
Pole Motion Sensor
The Selux outdoor rated sensor incorporates Passive Infrared (PIR) technology for motion sensing and also includes a built in photocell. Designed to mount directly through a 1/2” KO in a single gang faceplate on pole/column, the SBO utilizes 100% Digital Passive Infrared (PIR) technology that is tuned for walking size while preventing false tripping from the environment.
Series Optics Hand Hole Orientation Program Color Photocell
Feature Voltage
MS
Motion Sensor
1 270° coverage - Single Sensor
00D0 (0V=0%)
WH WhiteY Yes UNV
09 D1 (1V=10%) BK Black N No 347
18 D3 (3V=30%)BZ Bronze
480
27 D5 (5V=50%)
NOTE: Motion sensor comes programmed at 30% dimmed level with a 5 min. delay as default. All programming required after shipping by others.
12”(305mm)
Ouray 400 Sistema
Page 11 of 13 (Rev. 09/2020) ORY4S_ss_v6.3
In a continuing effort to offer the best product possible, we reserve the right to change, without notice, specifications or materials that in our opinion will not alter the function of the product. Specification sheets found at www.selux.us are the most recent versions and supercede all other printed or electronic versions.
• 100% Digital PIR Detection, excellent RF Immunity
• 270° coverage pattern
• Up to 30ft mounting
• IP66 Rated for outdoor applications
• Built-in 1kV surge protection
• No minimum load requirements
• Made for LED light source
• Interchangeable hot and load wires - impossible to wire backwards
• Adjustable time delays, max/min dim levels and ramp rates
• Programming button accessible without opening sensor or removing gaskets
• No field calibration or sensitivity adjustments required
• Non-volatile setting memory
• Convenient test mode
• Suitable for Title 24 applications
Motion Sensor Wiring Diagram
Pole Motion Sensor
LINECORD
BLKWHTBLKVIO
SBO SENSORGRY
GRN
WH
T
BLK
BLK
WH
TG
RN RED
ORG
BLK
WH
TG
RN
ORGRE
D
FIXT
URE
FEED
CO
RD
WEATHERPROOF WIRE CONNECTOR,600V 18-8GA
(SUPPLIED)
ATTACH CORD TO BACK OF SENSOR MOUNTING PLATEWITH 2 ZIP TIES (NOT SUPPLIED)
Ouray 400 Sistema
Page 12 of 13 (Rev. 09/2020) ORY4S_ss_v6.3
In a continuing effort to offer the best product possible, we reserve the right to change, without notice, specifications or materials that in our opinion will not alter the function of the product. Specification sheets found at www.selux.us are the most recent versions and supercede all other printed or electronic versions.
Catalog #: U4-R1-XX-XX-5G350-30-XX-UNVDelivered Lumens: 2012lm Input Watts: 19W Efficacy: 107 lm/WCCT: 3000KCRI (Ra): >80 Maximum candela of 1057 at 55° from vertical.IES classification: Type II Mounting Height: 12’ (3.6 m)BUG Rating: B1-U0-G1Power Factor: 0.977Total Harmonic Distortion: 10.5%
R1 Optics / 19W LED / 3000K CCT
Catalog #: U4-R2-XX-XX-5G350-30-XX-UNV Delivered Lumens: 2031lmInput Watts: 19W Efficacy: 108 lm/WCCT: 3000KCRI (Ra): >80 Maximum candela of 1593 at 57.5° from vertical.IES classification: Type IIIMounting Height: 12’ (3.6 m)BUG Rating: B1-U0-G1Power Factor: 0.977Total Harmonic Distortion: 10.5%
R2 Optics / 19W LED / 3000K CCT
Catalog #: U4-R3-XX-XX-5G350-30-XX-UNV Delivered Lumens: 2002lm Input Watts: 19W Efficacy: 106 lm/WCCT: 3000KCRI (Ra): >80 Maximum candela of 1336 at 62.5° from vertical.IES classification: Type IIIMounting Height: 12’ (3.6 m)BUG Rating: B1-U0-G1Power Factor: 0.977Total Harmonic Distortion: 10.5%
R3 Optics / 19W LED / 3000K CCT
Page 13 of 13 (Rev. 09/2020) ORY4S_ss_v6.3
In a continuing effort to offer the best product possible, we reserve the right to change, without notice, specifications or materials that in our opinion will not alter the function of the product. Specification sheets found at www.selux.us are the most recent versions and supercede all other printed or electronic versions.