www.huawei.com Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Security Level:INTERNAL 22/6/10 OptiX RTN 600 Introduction
www.huawei.com
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved.
Security Level:INTERNAL 23/5/3
OptiX RTN 600 Introduction
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 2Page 2Page 2
ForewordOptiX RTN 600 is a PDH/SDH integrated short-haul digital microwave transmission system developed by Huawei.
The maximum microwave transmission capacity is STM-1.
The system provides the backhaul transmission link in the mobile communication system or private network, and also networks with optical transmission equipments.
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 3Page 3Page 3
Objectives Upon completion of this course, you will be able to:
Describe the main characteristics of OptiX RTN 600. Describe the system structure ,software and hardware
structure of OptiX RTN 600. List the functions of boards in the IDU, ODU, Hybrid
coupler. Explain the equipment-level protection mode of OptiX
RTN 600.
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 4Page 4Page 4
Contents1. Equipment Overview
2. Equipment Structure
3. Equipment Protection
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 5Page 5Page 5
Contents1. Equipment Overview
1.1 Equipment Components IDU ODU Antenna Intermediate Frequency (IF) Cable Hybrid coupler
1.2 Equipment Characteristics
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 6Page 6Page 6
Equipment Components
Hybrid coupler
IF cable
IDU
ODU
Antenna
Pole
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 7Page 7Page 7
IDU Indoor unit (IDU) realizes the
mutual conversion between the service signal and IF analog signal. Two types of IDU are available:
IDU 610 is 1U high and supports one microwave direction.
IDU 620 is 2U high and supports maximum four microwave directions.
IDU 610
IDU 620
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 8Page 8Page 8
IF transit jumper IF cable
IF Cable The IF cable provides -48V power for ODU and transmits
the IF signal and ODU management signal between IDU and ODU.
Three types of IF cable in OptiX RTN 600: IF jumper: connection between IDU and other IF cable. 1/2 inch and RG-8U (1/4 inch) cable: connection between ODU
and IF jumper. RG-8U (1/4 inch) cable is used for the distance less than 180 meter. 1/2 inch cable is used for the distance between 180m and 300m.
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 9Page 9Page 9
ODU Outdoor unit (ODU) realizes the
mutual conversion between IF analog signal and RF signal.
ODU is irrelevant to the microwave transmission capacity. An ODU of the OptiX RTN 600 can support the transmission capacity from 4 E1 to one STM-1.
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 10Page 10Page 10
Hybrid Coupler When two ODUs share one antenna, the ODUs must be
connected to an RF signal coupler/ splitter (hybrid coupler). Then, the hybrid coupler is connected to the antenna.
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 11Page 11Page 11
Antenna The antenna performs the
directional transmission and reception of RF signals. The main parameters are frequency band, diameter and antenna gain.
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 12Page 12Page 12
Equipment Characteristics PDH/SDH integrated microwave transmission system. The modulation mode and link capacity are set through
software. Microwave link supports the SNCP. Built-in ADM provides flexible service add/drop function. Providing the clock tracing function. Supporting mobile FLASH card. The boards of IDU 610 and IDU 620 are compatible each
other.
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 13Page 13Page 13
Questions What are the components of OptiX RTN 600? What are the
functions of them? What about the connection relation among the components?
What are the characteristics of OptiX RTN 600 digital microwave equipment?
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 14Page 14Page 14
Contents1. Equipment Overview
2. Equipment Structure
3. Equipment Protection
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 15Page 15Page 15
Contents Equipment Structure
2.1 System Diagram 2.2 Software Structure 2.3 IDU Structure and Board
2.4 ODU Interfaces and Parameters
2.5 Hybrid coupler Parameters
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 16Page 16Page 16
IDU Structure ( IDU 610) IDU 610 is 1U high and adopts
the nature heat dissipation mode. Support 1+0 configuration.
EXT slot3
PXC slot1
EXT slot4
SCC slot2
Note: The slot numbering rule is from bottom to up and left to right.
IF boardLine board and tributary board
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 17Page 17Page 17
IDU Structure ( IDU 620) IDU 620 is 2U high and
dissipates heat through wind cooling.
Support a maximum of 4+0 configuration or two groups of 1+1 configuration.
slot20 PXC slot3
PXC slot1EXT slot4SCC slot2
EXT slot5 EXT slot6EXT slot7 EXT slot8 The slot
numbering rule is the same as OptiX RTN 610 .
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 18Page 18Page 18
IDU Board -- IF Board IF1A
ODU powersupply switch
IF cable interface Indicators
The IF board receives and transmits 1x IF signal. It realizes the conversion between baseband digital signal and IF signal, it also provides -48V DC power supply and management signal to the ODU.
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 19Page 19Page 19
IF1A
-48V power supply is output directly to ODU.
Support the DC-C grounding mode only.
IF1B
The -48V power is isolated by the DC-DC power supply module and then sent to the ODU.
Support DC-I and DC-C grounding modes.
IF Board -- Types
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 20Page 20Page 20
IF Board -- Board Installation
slot20 PXC slot3
PXC slot1EXT slot4SCC slot2
EXT slot7
EXT slot3PXC slot1
EXT slot4SCC slot2
IDU 610
IDU 620
EXT slot5EXT slot8EXT slot6
①②
③④
Paired Slots
Paired Slots
No limitation for board installation under HSB configuration. Only installing IF boards in paired slots under SD or FD configuration.Recommended installation sequence for IF boards
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 21Page 21Page 21
IF Board -- IF PerformanceItem Performance
4 X E1 8 X E1 16 X E1 STM-1Modulation mode QPSK 16QAM QPSK 16QAM QPSK 16QAM 128QAM
Channel spacing (MHz))
7 3.5 13.75 /14 a 7 27.5/
28 b13.75 /14
a 27.5 / 28 b
Coding scheme
PDH signal is coded through the Reed-Solomon (R-S).SDH signal is coded through the Trellis-Coded Modulation (TCM) and R-S.
Remarks a: At the 18G band, the channel spacing is 13.75MHz, At other bands, the channel spacing is 14MHz.b: At the 18G band, the channel spacing is 27.5MHz. At other bands, the channel spacing is 28MHz.
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 22Page 22Page 22
IF Board -- Indicators
The space link is faulty. OnThe space link is normal.On
LINK
No services are configured. Off
The service has a minor or remote alarm.On
The service has a critical or major alarm.OnThe service is normal.On
SRV
The board is not working, not created, or has no input power.
OffThe board hardware is faulty.OnThe board is working normallyOn
STAT
MeaningStatusIndicator
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 23Page 23Page 23
IF Board -- IndicatorsIndicator Status Meaning
ODU On The ODU is normal.On The ODU is faulty.
BEROn The microwave BER exceeds the
threshold.Off The microwave BER does not
exceed the threshold.
RMTOn The remote equipment has a
Remote Defect Indication (RDI).Off The remote equipment has no
RDI.
ACT On The board is in active state. Off The board is in standby state.
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 24Page 24Page 24
IDU Board -- Tributary Board PH1
Indicator 1-8 channel E1
DB44 interfaces
9-16 channel E1DB44 interfaces
The tributary board processes multi-channel E1 signals and provides the E1 interface.
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 25Page 25Page 25
Tributary Board -- Board installation
slot20 PXC slot3
PXC slot1 SCC slot2
EXT slot7
PXC slot1EXT slot4SCC slot2
IDU 610
IDU 620
EXT slot5EXT slot8EXT slot6
①
Recommended installation sequence for TU boards
②③
④EXT slot4
EXT slot3
⑤
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 26Page 26Page 26
Tributary Board -- IndicatorsIndicato
r Status Meaning
STAT
On The board is working normally.On The board hardware is faulty.Off The board is not working, or
created, or has no input power.
SRV
On The service is normal.On The service has a critical or major
alarm.On The service has a minor or remote
alarm.Off No services are configured.
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 27Page 27Page 27
IDU Board -- Line Board SD1/SDE
SMBelectrica
l interface
LC optical
interface
The line board processes 1-2 channel STM-1 signal and provides STM-1 optical or electrical interface.
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 28Page 28Page 28
Line Board -- Types
SD1
Dual-port STM-1 optical interface
Ie-1interface
S-1.1interface
L-1.1interface
L-1.2interface
SL1
Single- port STM-1 optical interface
Ie-1interface
S-1.1interface
L-1.1interface
L-1.2interface
SDE
dual-port STM-1 electrical interface
SLE
Single-port STM-1 electrical interface
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 29Page 29Page 29
Line Board -- Board installation
slot20 PXC slot3
PXC slot1 SCC slot2
PXC slot1EXT slot4SCC slot2
IDU 610
IDU 620
EXT slot5EXT slot8EXT slot6
①②③
④EXT slot4
EXT slot3
⑤ EXT slot7
Recommended installation sequence for LU boards
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 30Page 30Page 30
Line Board -- Interface Parameters
Item PerformanceNominal bit rate (kbit/s) 155520
Application code Ie-1 S-1.1 L-1.1 L-1.2
Optical fiber typeMulti-mode fiber
G.652 G.652 G.652
Transmission distance (km) 0.5 15 40 80/100
Working wavelength (nm)
1260-1360
1261-1360
1263-1360 1480-1580
Average transmit optical power (dBm)
- 19~ -14
- 15~ -8 - 5~0 - 5~0
Minimum sensitivity (dBm) -23 -28 -34 -34
Minimum overload (dBm) -14 -8 -10 -10Minimum extinction ratio
(dB) 8.2 8.2 10 10
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 31Page 31Page 31
Line Board -- IndicatorsIndicat
or Status Meaning
STAT
On The board is working normally.On The board hardware is faulty.Off The board is not working, or created, or no
power supply.
SRV
On The service is normal.On The service has a critical or major alarm.On The service has a minor or remote alarm.Off No services are configured.
LOS1On No.1 opt. port on the SL1/SD1 board has a
R_LOS alarm.Off No.1 opt. port on the SL1/SD1 board has no
R_LOS alarm.
LOS2On No.2 opt. port on the SD1 board has a R_LOS
alarm.Off No.2 opt. port on the SD1 board has no R_LOS
alarm.
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 32Page 32Page 32
IDU Board -- Ethernet Board EFT4 EFT4 is a Ethernet transparent transmission board. It receives,
transmits and processes four-channel Ethernet signals.
slot20 PXC slot3
PXC slot1 SCC slot2
EXT slot7
PXC slot1EXT slot4SCC slot2
IDU 610
EXT slot5EXT slot8EXT slot6
①②③
④EXT slot4
EXT slot3
IDU 620
Recommended installation sequence for EFT4 boards
⑤
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 33Page 33Page 33
Power Cross-Connection Clock Board -- PXC
IndicatorIDUPowerswitch
External clock/Waysideinterface
Power inputinterface
The PXC board realizes the cross-connection (16×16 VC4) and clock functions , it also provides the DC power for other boards.
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 34Page 34Page 34
PXC -- Board Installation
IDU 610
slot20 PXC slot3
PXC slot1 SCC slot2
EXT slot7
IDU 620
EXT slot5EXT slot8EXT slot6
①② EXT slot4
PXC slot1EXT slot4SCC slot2
EXT slot3
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 35Page 35Page 35
PXC -- IndicatorsIndicator Status Meaning
STAT
On The board is working normally.On The board hardware is faulty.Off The board is not working, or not created,
or has no input power.
PWR
On The power is normal.On +3.3V power fault or -48V input power
abnormalOff No input power.
SYNCOn The clock is normal.On The clock source is lost or the switch
exists.
ACT On The board is in active state.Off The board is in standby status.
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 36Page 36Page 36
IDU Board -- SCC SCC provides system control and communication functions, auxiliary
interfaces management and standby internal power module.
Indicators
Indicator test button
Reset button
NM serial port
NM interface
NM cascaded interface
Order wire
Asynchronous data and Boolean interface
Flash memory
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 37Page 37Page 37
SCC Board -- Board Installation
slot20 PXC slot3
PXC slot1 SCC slot2
EXT slot7
IDU 610
IDU 620
EXT slot5EXT slot8EXT slot6EXT slot4
PXC slot1EXT slot4SCC slot2
EXT slot3
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 38Page 38Page 38
SCC Board -- NM Cable Connection The SCC board sets the NE ID through the software. The initial NE ID
is set to 49136 by default. The IP address of NE is also set through the software. The IP address
is set to 129.9.0.ID by default.
NMSConnected by Ethernet cable
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 39Page 39Page 39
SCC Board -- Wrong Connections
Multiple NEs are cascaded as a
loop.
Self-loop of single NE
The connection will cause NE reset frequently.
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 40Page 40Page 40
SCC Board -- IndicatorsIndicat
orStatus Meaning
STAT
On The board is working normally.On The board hardware is faulty.Off The board is not working, or not
created, or has no input power.
PROG
On 100 ms and off 100 ms
During the board power-on/reset, loading the software.
On 300 ms and off 300 ms
The board software is introduced through the BIOS during the power-on/reset.
On Initialize the upper layer software.On 100 ms and off 100 ms
During the board power-on/reset, BOOTROM self-test fails.
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 41Page 41Page 41
SCC Board -- IndicatorsIndicat
orStatus Meaning
PROG
On During the board power-on/reset, the memory self-test fails or the upper layer software loading fails, or during the board running, the logical file and software are lost.
Off The software is normal.
ALM
On The system is normal.On The system has a critical or major alarm.On The system has a minor alarm.Off The system has no input power.
MANTOn The system is in maintenance state ( that is,
loop-back, laser power-off, and ODU transceiver mute)
Off The system is in working state.
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 42Page 42Page 42
IDU Board -- Fan Board (FAN)Indicato
r slot20 PXC slot3
PXC slot1 SCC slot2
EXT slot5EXT slot8EXT slot6EXT slot4
EXT slot7
Fan direction
Indicator Status Meaning
FAN
On The fan is working normally.
On The board is faulty.Off The board has no input
power.
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 43Page 43Page 43
Contents Equipment Structure
2.1 System Diagram 2.2 Software Structure 2.3 IDU Structure and Board 2.4 ODU Interfaces and Parameters
2.5 Hybrid coupler Parameters
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 44Page 44Page 44
ODU -- Interface
< 5 kg Power consumption: < 40WWeight:
< 260 mm X 260 mm X 92 mm (width X height X depth)Dimension:
Grounding double-screw bolt
RSSI test interface IF interface
Antenna port
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 45Page 45Page 45
ODU -- Main Performance
Item Performance7G 15G 18G 23G
Frequency range (GHz)
7.114-7.743
14.501-15.257
17.685-19.710
22.000-23.608
TR spacing (MHz) 161 420 1010 1008
Channel spacing (MHz)
3.5, 7, 14, 28
3.5, 7, 14, 28
3.5, 7, 13.75, 27.5
3.5, 7, 14, 28
The ODU frequency bands covers from 7G to 38G. Some commonly used frequency band indexes are listed in the table.
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 46Page 46Page 46
ODU -- Main Performance (cont.)
Item Performance7G 15G 18G 23G
maximum Tx (dBm)
QPSK 25.5 24.5 24 22.516QAM 21 20 20 19128QAM 15 14 14 13
minimum Tx (dBm) -4
Transceiver frequency
stability (ppm)±5
[Note]: If the transmitting power exceeds the maximum level ,the Bite Error will occur in the service.
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 47Page 47Page 47
Contents Equipment Structure
2.1 System Diagram 2.2 Software Structure 2.3 IDU Structure and Board 2.4 ODU Interfaces and Parameters 2.5 Hybrid coupler Parameters
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 48Page 48Page 48
Hybrid coupler
Secondary tributary port
Antenna port
Primary tributary port
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 49Page 49Page 49
Hybrid coupler -- Main Performance
Item PerformanceFlatness (dB) ≤0.5Attenuation (dB) ≤1.7Coupling (dB) 6.5±0.6Isolation (dB) ≥25Standing wave ratio ≤1.2Weight (kg) <5
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 50Page 50Page 50
Summary Equipment Structure of OptiX RTN 600
Software Structure: the host and board software are integrated in the SCC and the ODU is a logical board.
IDU: includes IDU 610 and IDU 620. IF board: IF1A and IF1B Line board: SL1, SD1, SLE, and SDE Tributary board: PH1 and PO1 Data board: EFT4 Power cross-connection clock board: PXC System control and communication board: SCC Fan board: FAN
ODU: interface, dimension, weight, power consumption, power indicator, and frequency indicator
Hybrid coupler: interface and main indicators
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 51Page 51Page 51
Contents1. Equipment Overview
2. Equipment Structure
3. Equipment Protection
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 52Page 52Page 52
1+1 Hot Standby Backup (1+1HSB)
Cross-connection board Service
board
ActiveIF BoardActive
ODU
Hybrid couplerAntenna
StandbyIF Board
StandbyODUmut
e
mute
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 53Page 53Page 53
1+1 Space Diversity (1+1 SD)
Cross-connection board Service
board
ActiveIF BoardActive
ODU
Antenna 1
StandbyIF Board
StandbyODU
Antenna 2
Mute
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 54Page 54Page 54
1+1 Frequency Diversity (1+1 FD)
Cross-connectionboard Service
board
ActiveIF Board
ActiveODU
HybridAntenna
StandbyIF Board
StandbyODUtf2
rf2
tf1rf1
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 55Page 55Page 55
Space Frequency Diversity (1+1 SD+FD)
Cross-connectionboard Service
board
ActiveIF Board
ActiveODU
Antenna 1
StandbyIF board
StandbyODU
Antenna 2
tf2rf2
tf1rf1
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 56Page 56Page 56
SummaryContents Review Main characteristics System Structure, Software and Hardware Structure Board Functions and Signal flow in the IDU ODU and Hybrid coupler Features and Functions Equipment Level Protection Actions and Signal flow Microwave Link Protection Actions and Signal flow