OPTIMIZING ULTRASOUND OF THE PAINFUL HIP ARTHROPLASTY: Demonstrating a Novel Protocolized Approach IA Siddiqui, K Satchithananda, AK Lim, S Sabah, J Henckel, JA Skinner & AJ Hart [email protected]University College London Institute of Orthopedics & Musculoskeletal Science, Royal National Orthopedic Hospital, United Kingdom
26
Embed
OPTIMIZING ULTRASOUND OF THE PAINFUL HIP ARTHROPLASTY: Demonstrating a Novel Protocolized Approach IA Siddiqui, K Satchithananda, AK Lim, S Sabah, J Henckel,
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
OPTIMIZING ULTRASOUND OF THE PAINFUL HIP ARTHROPLASTY: Demonstrating a Novel Protocolized Approach
IA Siddiqui, K Satchithananda, AK Lim, S Sabah, J Henckel, JA Skinner & AJ Hart
OPTIMIZING ULTRASOUND (US) OF THE PAINFUL HIP ARTHROPLASTY: Demonstrating a Novel Protocolized Approach
ReferencesBal BS, Lowe JA. Muscle damage in minimally invasive total hip arthroplasty: MRI evidence that it is not significant. Instr Course Lect. 2008;57:223-229.
FDA: Orthopaedic and Rehabilitation Devices Panel of the Medical Devices Advisory Open Panel Meeting, June 2012 [Online] Available from: http://www.fda.gov/AdvisoryCommittees/CommitteesMeetingMaterials/MedicalDevices/MedicalDevicesAdvisoryCommittee/OrthopaedicandRehabilitationDevicesPanel/ucm309184.htm [Accessed 08/10/2012].
Hart AJ, Satchithananda K, Liddle AD, et al. Pseudotumors in association with well-functioning metal-on-metal hip prostheses: a case-control study using three-dimensional computed tomography and magnetic resonance imaging. J Bone Joint Surg Am. 2012;94(4):317-325.
Hayter CL, Potter HG, Su EP. Imaging of metal-on-metal hip resurfacing. Orthop Clin North Am. 2011;42(2):195-205, viii.
Kwon YM, Ostlere SJ, McLardy-Smith P, Athanasou NA, Gill HS, Murray DW. "Asymptomatic" pseudotumors after metal-on-metal hip resurfacing arthroplasty: prevalence and metal ion study. J Arthroplasty. 2011;26(4):511-518.
OPTIMIZING ULTRASOUND (US) OF THE PAINFUL HIP ARTHROPLASTY: Demonstrating a Novel Protocolized Approach
Long SS, Surrey D, Nazarian LN. Common sonographic findings in the painful hip after hip arthroplasty. J Ultrasound Med. 2012;31(2):301-312.
MHRA. Medical Device Alert: All metal-on-metal (MoM) hip replacements (MDA/2012/036) [Online] Available from: http://www.mhra.gov.uk/home/groups/dts-bs/documents/medicaldevicealert/con155767.pdf [Accessed 08/10/2012].
Nishii T, Sakai T, Takao M, Yoshikawa H, Sugano N. Ultrasound Screening of Periarticular Soft Tissue Abnormality Around Metal-on-Metal Bearings. J Arthroplasty. 2011.
Pandit H, Glyn-Jones S, McLardy-Smith P, et al. Pseudotumours associated with metal-on-metal hip resurfacings. J Bone Joint Surg Br. 2008;90(7):847-851.
Sabah SA, Mitchell AW, Henckel J, Sandison A, Skinner JA, Hart AJ. Magnetic resonance imaging findings in painful metal-on-metal hips: a prospective study. J Arthroplasty. 2011;26(1):71-76, 76 e71-72.
Smith AJ, Dieppe P, Vernon K, Porter M, Blom AW. Failure rates of stemmed metal-on-metal hip replacements: analysis of data from the National Joint Registry of England and Wales. Lancet. 2012;379(9822):1199-1204.
Willert HG, Buchhorn GH, Fayyazi A, et al. Metal-on-metal bearings and hypersensitivity in patients with artificial hip joints. A clinical and histomorphological study. J Bone Joint Surg Am. 2005;87(1):28-36.
OPTIMIZING ULTRASOUND (US) OF THE PAINFUL HIP ARTHROPLASTY: Demonstrating a Novel Protocolized Approach
OPTIMIZING ULTRASOUND OF THE PAINFUL HIP ARTHROPLASTY: Demonstrating a Novel Protocolized Approach