Top Banner
Optical Biometer / Topographer 1 OA-2000 Montag, 14. April 14
31

Optical Biometer / Topographer OA-2000

Feb 20, 2022

Download

Documents

dariahiddleston
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: Optical Biometer / Topographer OA-2000

Optical Biometer / Topographer

1

OA-2000

Montag, 14. April 14

Page 2: Optical Biometer / Topographer OA-2000

2

Montag, 14. April 14

Page 3: Optical Biometer / Topographer OA-2000

2

Montag, 14. April 14

Page 4: Optical Biometer / Topographer OA-2000

2

IOL calculation for both eyes in 40 seconds!

Montag, 14. April 14

Page 5: Optical Biometer / Topographer OA-2000

Comprehensive Biometry of Two Eyes

3

in 40 seconds!

• Topography• K values• Axial length• Pupil width • White to white (W-to-W)• Central cornea thickness (CCT)• Anterior chamber depth (ACD) • Lens thickness (LT)

Fast and easy to use:

Montag, 14. April 14

Page 6: Optical Biometer / Topographer OA-2000

Fast and easy to use!

4

• Patient entry • Alignment• Measurement• Analysis • IOL calculation

• OKULIX• EASY IOL• Formulae

• “ULIB“ A-constant import

=> result oriented work flow!

Fast and easy to use:

Montag, 14. April 14

Page 7: Optical Biometer / Topographer OA-2000

5

manually via touch screen or via bar-codePatient ID entry

Fast and easy to use:

Montag, 14. April 14

Page 8: Optical Biometer / Topographer OA-2000

6

Well-known from:• RC-5000• RT-7000 • EM-3000• FT-1000• SS-1000 CASIA

Now on a new basis;touch screen operated, more measurements in less time than the competitors

3-D auto-tracking Fast and easy to use:

Montag, 14. April 14

Page 9: Optical Biometer / Topographer OA-2000

Fast and easy to use:

7

one click to IOL

result-oriented work flow

Montag, 14. April 14

Page 10: Optical Biometer / Topographer OA-2000

8

IOL Calculation With Gaussian Optics Formulae

OA-2000 is prepared for: • Contact • Immersion• Optical

By reducing our potential we can simulate theIOL-master in order to use ULIB data

Montag, 14. April 14

Page 11: Optical Biometer / Topographer OA-2000

Every mode needs an own A-constant

9

Montag, 14. April 14

Page 12: Optical Biometer / Topographer OA-2000

10

Why to cut our potential? Courage for precision!

Real topography for IOL calculation by ray tracing: OKULIX and EASY IOL

• All eye types become „normal“ • IOL calculation becomes fast and easy

even after refractive surgery ...

Montag, 14. April 14

Page 13: Optical Biometer / Topographer OA-2000

11

As soon as a cornea is asymmetric, a keratometer will be insufficient! Only solution: topography

Aladdin

TMS-4

TMS-4 vs OA-2000 G6 like G4

1000pts@4mm9 rings/256

2304pts@5,5mm ?? 64000€

2 rings 360pts @1.2mm and new on 1.65

Al-Scan IOL-master

6 points @1.5 keratometer

1 ring 32 [email protected] with optional ring cone

Lenstar IS900

Montag, 14. April 14

Page 14: Optical Biometer / Topographer OA-2000

12

Measuring of pupil and cornea diameter (W-to-W) by means of video analysis

--- Pupil diameter: important for calculating the best focus with OKULIX--- White to White is used in ICL calculation.

Fast and easy to use:

Montag, 14. April 14

Page 15: Optical Biometer / Topographer OA-2000

13

Comparison of Axial SNRComparison of Axial SNRComparison of Axial SNR OA-2000 OA-1000 IOL-Master

No. ID R/L SNR Max SNR Max SNR

8 6484 R 317.2 5.4 3.2

11 600 L 111.8 4.0 5.5

13 7998 R 241.1 4.2 2.6

17 8062 L 127.0 6.8 2.7

18 8110R 71.5 5.3 4.1

18 8110L 76.6 5.3 4.7

A very high number of A-scans and special scanning technique are the solution!

Fast and easy to use:

Dense cataract? No problem:

Montag, 14. April 14

Page 16: Optical Biometer / Topographer OA-2000

14

=> CCT => Cornea Shape => AXl

Only one critical case:

-10 myopia normal +10 hyperopia

CCT -130µm

CCT +/-0

CCT +/-0

assumed error+2,4D

assumed error-2,4D

long AxL normal AxL short AxL

eyes after refractive surgery

Future: Cornea guardFast and easy to use:

Montag, 14. April 14

Page 17: Optical Biometer / Topographer OA-2000

15

Post-OP IOL position is critical in short eyes.

Solution:EASY IOL and OKULIX for precise prediction of post-OP IOL position

ACD and LT are essential for better IOL calculation!

20mm

Δ∆2.7 D

short eye

28mm

Δ∆0.4 D

longer eye

35 D IOL

7,5 D IOL

19 D IOL

normal eye

Δ∆1,2 D

IOL shift: ∆0.5mm

Fast and easy to use:

Montag, 14. April 14

Page 18: Optical Biometer / Topographer OA-2000

Comprehensive Biometry of Two Eyes

16

Analysis

• Topography / K-values

• Toric eyes /steepest meridian

• Pupil width • White to white (W-to-W)

• Axial length• Central cornea thickness (CCT)• Anterior chamber depth (ACD) • Lens thickness (LT)

Fast and easy to use:

Montag, 14. April 14

Page 19: Optical Biometer / Topographer OA-2000

17

Topography link to Ray-tracing.

Montag, 14. April 14

Page 20: Optical Biometer / Topographer OA-2000

18

OKULIX

IOL calculation by Ray-tracing

Montag, 14. April 14

Page 21: Optical Biometer / Topographer OA-2000

19

Topography steepest axis

Montag, 14. April 14

Page 22: Optical Biometer / Topographer OA-2000

20

Pupil width (Pø) and White to white (W-to-W)

Montag, 14. April 14

Page 23: Optical Biometer / Topographer OA-2000

21

All sequences in dual view

Montag, 14. April 14

Page 24: Optical Biometer / Topographer OA-2000

22

Company TOMEY Ziemer Group Topcon Haag-Streit Zeiss Nidek

TYPE: OA-2000 G6 Aladdin Lenstar-900 IOL Master 500 AL-Scan

Picture:

Function: Optical length

TOPO K1 / K2

Optical length TOPO K1 / K2

Scheimpflug

Optical length TOPO K1 / K2

------

Optical length ---

K1 / K2 (32points)

Optical length ---

K1 / K2

Optical length ---

K1 / K2

Applications:

CCTACD

Lens thickness Axial length

--- W to W

Pupil width Ref (optional)

Topograpy---

Pachy map ACD

Lens thickness Axial length

--- W to W

Pupillometry ---

TopograpyScheimpflug

CCT ACD

--- Axial length

--- W to W

---

Topograpy

CCT ACD

Lens thickness Axial length

Retina thickness W to W

Pupillometry ---

topo +5000€

--- ACD ---

Axial length ---

W to W

--- ---

Pachymetry ACD

--- Axial length

--- W to W

PD --- ---

3D tracking 3D --- ? --- --- 3D

The Competitors

Montag, 14. April 14

Page 25: Optical Biometer / Topographer OA-2000

23

Company TOMEY Ziemer Group Topcon Haag-Streit Zeiss Nidek

TYPE: OA-2000 G6 Aladdin Lenstar-900 IOL Master 500 AL-Scan

Picture:

Optional Ultrasoundbiometer

AL-4000 (KV) NA NA Aviso A/B (KV) Accutome

A-Scan (none KV)

IntergreatedBio (only

-40mm) / Pachy(none KV)

IOL Calculation Raytracing

OKULIX optionalEasy IOL NA optional

OKULIX optional OKULIX

IOL Calculation Formulae

Haigis, HofferQ,

Holladay 1, SRK/T, SRK II,

Shammas PL

NA

Haigis, Hoffer Q,Holladay 1

SRK/T SRK II

Camellin-Calossi

Haigis, HofferQ,

Holladay 1, SRK/T, SRK II, Masket, Modified Masket,

Shammas PL

Haigis Hoffer Q

Holladay 1 SRK® / T SRK® II

HAIGIS L

Haigis, Hoffer Q, Holladay 1

SRK/T SRK II

Camellin-Calossi

The Competitors...

Montag, 14. April 14

Page 26: Optical Biometer / Topographer OA-2000

A further click to documentation...

24

Montag, 14. April 14

Page 27: Optical Biometer / Topographer OA-2000

Summary OA-2000 Optical Biometer

25

• Topography• K values• Axial length• Pupil width • W-to-W• CCT• ACD • LT

• Patient entry • 3D eyetracking• Fast measurement• Easy analysis • IOL calculation

• OKULIX• EASY IOL• Formulae

• ULIB compatible

Montag, 14. April 14

Page 28: Optical Biometer / Topographer OA-2000

26

Montag, 14. April 14

Page 29: Optical Biometer / Topographer OA-2000

26

Montag, 14. April 14

Page 30: Optical Biometer / Topographer OA-2000

26

IOL calculation for both eyes in 40 seconds!

Montag, 14. April 14

Page 31: Optical Biometer / Topographer OA-2000

27

Tank you! ok now ask me the question...

When?

Montag, 14. April 14