Infrared Refrigerant Leak Detector Model: SRL2 OPERATOR’S MANUAL Description The SRL2 uses infrared optics to create a portable refrigerant leak detector technology that has a superior combination of sensitivity, speed, sensor life, battery life, portability, and ease of use. Gas is pumped through the tip of the wand into the sensor within the SRL2 body. The sensor detects changes in concentration, not absolute con- centration, making it easy to detect leaks even in areas with refrigerant in the air. The SRL2 detects leaks as small as 0.1 oz/year, which exceeds the toughest SAE J1627 standards. The SRL2 comes with wall and car chargers for its ultra-compact Li-ion polymer battery which powers the SRL2 for 8hrs of continuous operation before a recharge is needed. That’s long enough to last your entire workday. Unlike many leak detectors, oil vapor does not trigger the SRL2. The SRL2 has vari- able sensitivity set- tings, keeping ‘nui- sance tripping’ to a minimum. A quick and automatic 30 second self-calibration upon power-up ensures optimal performance. A built in replaceable filter blocks moisture and harmful particulates. The SRL2 also has a mute button and a peak hold func- tion. Specifications Sensing element: Enhanced infrared photo optics Sensor life: 10 years Refrigerants: HFC, CFC, HCFC, and blends Sensitivity level (per SAEJ1627): HIGH: 0.1 oz/year and higher MED: 0.5 oz/year and higher LOW: 1.0 oz/year and higher Response time: 0.5 to 1 second Auto off: 10 minutes after no activity Battery: 7.4VDC(nominal), 900mAh rechargeable lithium ion polymer (model H702550-2S) techni- cian-replaceable battery. Battery life: 8 hours continuous use prior to needing a charge. Degradation (10-5%) after 500 charge/discharge cycles or two years, whichever comes first. Low battery LED: Illuminated when approximate- ly 1 hour of battery life remains. Charge time: Less than 4 hours with either sup- plied charger. Operating environment: 32ºF (0°C) to 122ºF (50°C) at <75%RH Storage environment: <80%RH meter and batt. For 80% battery recovery: -4ºF (-20°C) to 140ºF (60°C) less than 1 month -4ºF (-20°C) to 113ºF (45°C) less than 3 months -4ºF (-20°C) to 68ºF (20°C) less than 1 year Patents: #6,791,088 and #7,022,993 Accessories included: wall charger, car charger, case, 10 extra filters, 5 spare O-ring rubber gas- kets, battery (installed), and operator’s manual. Quick Tips 1. Keep the wand tip moving past suspected leak locations. 2. Once a leak is detected, sweep the wand back over to pinpoint. 3. To pinpoint larger leaks adjust sensitivity. T2 T2 PEAK MUTE ON/OFF ON/OFF L/M/H SENSITIVITY H M L PEAK LOW-BATT PRESS FOR 1 SECOND S RL2 Infrared Refrigerant Leak Detector SENSITIVITY H M L PEAK LOW-BATT WARNING DO NOT open battery compartment or meter case. Battery must be replaced by Fieldpiece. DO NOT charge battery with any other charg- er than those that came with the instrument! DO NOT use the SRL2 without the proper fil- ter correctly installed. Read and follow the Lithium Battery Care section in this manual. ! ! Operation ON/OFF Protection To turn on/off the SRL2 press and hold the ON/OFF button for one second. This slight delay protects against inadvertant pressing. If you forget to turn it off, it will automatically go off in 10 minutes. LED Bar Graph Display The eight segment LED display indicates the degree of change in refrigerant concentration. As the concentration of refrigerant in the air increases, so does the number of lit bars on the display. L/M/H Button (Sensitivity) Set the sensitivity level by pressing the L/M/H but- ton. Low(L), medium(M), or high(H) sensitivity will be indicated by their respective LED. Use the highest sensitivity that will not give you false indications of a leak. The higher the concen- tration of refrigerant in the ambient air, the lower the sensitivity setting should be to minimize false trips. Mute Button Pressing the MUTE button toggles the sound of the SRL2 on and off. Peak Button The PEAK function holds the highest change in concentration achieved while continuing to detect leaks. Press PEAK to toggle this function on and off. Turning the PEAK function off will clear the peak change. The PEAK LED will light when PEAK func- tion is on. Leak Detection Procedure Keep the SRL2 away from any areas of potential refrigerant leakage until the warm-up and calibration period is over. The warm-up and calibration sequence lasts about 30 seconds after ON/OFF is pressed. On startup, meter defaults to high sensitiv- ity. The most likely points for refrigerant leaks are at the soldered joints in refrigerant lines and changes in cross section or direction of these lines. The SRL2 detects changes in concentration of refrigerant, not the absolute concentration of refrig- erant. This lets the user easily detect leaks in places that may have refrigerant in the air, such as a refrig- erator leaking into an enclosed space. Because the SRL2 detects change, there is a specific “double- pass” method used to find leaks. 1. The tip of the wand should be fairly close to the line. You may need to be within 1/4” of a small leak to detect it. In this case, using a second hand to guide the tip along refrigerant lines may be helpful. 2. Keep the tip moving along refrigerant lines at a rate of 1-3 inches per second. 3. Once the SRL2 indicates a change in concentra- tion, note the spot on the line and keep the tip moving past the potential leak to refresh the air space within the SRL2 with clean air. (Note: If the SRL2 wand moves through a very high con- centration of refrigerant, you may need to use in fresh air for 4 seconds before moving to step 4 in order to clear the refrigerant within the SRL2.) 4. Return the tip back to, and past, the spot first indicated. When the SRL2 indicates a second change, note the spot on the line. The source of the leak will be near the midpoint between the two noted spots of indication. 5. Very high concentrations of refrigerant can cause an overload which can take a few sec- onds to clear. Warranty and Service The product is warranted to the original purchas- er against defects in material or workmanship for a period of one (1) year from the date of purchase. During the warranty period, Fieldpiece Instruments will, at its option, replace or repair the defective unit. This warranty does not apply to defects resulting from abuse, neglect, accident, unauthorized repair, alteration, or unreasonable use of the instrument. Any implied warranty arising out of the sale of Fieldpiece's products including but not limited to implied warranties of merchantability and fitness for purpose are limited to the above. Fieldpiece shall not be liable for incidental or consequential dam- ages. Any defective SRL2 should be returned to Fieldpiece Instruments for warranty service along with proof of purchase. Call Fieldpiece for a return material authorization (RMA). For out of warranty service, send the SRL2 meter with battery installed along with an RMA number. Your SRL2 will be repaired or replaced at Fieldpiece's option. Repair price for SRL2 meter is $155. Repair price for SRL2 battery is $45. Fieldpiece Instruments, Inc. 580 West Central Ave. Suite A Brea, CA 92821 Phone: (714) 257-9060 Fax: (714) 257-9069 www.fieldpiece.com SRL2 testing an A-coil in an evaporator, 1/4” from the line. 1/4”
2

Operation Model: SRL2 Leak Detector Refrigerant Infrared ...€¦ · Leak Detector Model: SRL2 OPERATOR’S MANUAL Description The SRL2 uses infrared optics to create a portable refrigerant

Jul 26, 2020

Download

Documents

dariahiddleston
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: Operation Model: SRL2 Leak Detector Refrigerant Infrared ...€¦ · Leak Detector Model: SRL2 OPERATOR’S MANUAL Description The SRL2 uses infrared optics to create a portable refrigerant

Infrared R

efrigerantL

eak Detector

Model: SR

L2

OPE

RATO

R’S M

AN

UA

L

DescriptionThe

SR

L2 uses

infrared optics

to create

aportable refrigerant leak detector technology thathas a superior com

bination of sensitivity, speed,sensor life, battery life, portability, and ease of use.

Gas is pum

ped through the tip of the wand into

the sensor

within

the S

RL2

body. The

sensordetects changes in concentration, not absolute con-centration, m

aking it easy to detect leaks even inareas w

ith refrigerant in the air. The S

RL2 detects leaks as sm

all as 0.1 oz/year,w

hich exceeds the toughest SA

E J1627 standards.

The SR

L2 comes w

ith wall and car chargers for its

ultra-compact Li-ion polym

er battery which pow

ersthe S

RL2 for 8hrs of continuous operation before a

recharge is needed. That’s long enough to last yourentire w

orkday.U

nlike many leak detectors, oil vapor does not

trigger the SR

L2.The S

RL2 has vari-

able sensitivity

set-tings,

keeping ‘nui-

sance tripping’

to a

minim

um. A

quick andautom

atic 30 second self-calibration upon power-up

ensures optimal perform

ance. Abuilt in replaceable

filter blocks moisture and harm

ful particulates. TheS

RL2 also has a m

ute button and a peak hold func-tion.

Specifications Sensing elem

ent:Enhanced infrared photo optics

Sensor life: 10 yearsR

efrigerants:HFC

, CFC

, HC

FC, and blends

Sensitivity level (per SAEJ1627):

HIG

H: 0.1 oz/year and higher

ME

D:

0.5 oz/year and higherLO

W:

1.0 oz/year and higherR

esponse time: 0.5 to 1 second

Auto off:10 m

inutes after no activityB

attery:7.4VD

C(nom

inal), 900mA

h rechargeablelithium

ion polymer (m

odel H702550-2S

) techni-cian-replaceable battery.

Battery life:8 hours continuous use prior toneeding a charge. D

egradation (10-5%) after

500 charge/discharge cycles or two years,

whichever com

es first.Low

battery LED: Illum

inated when approxim

ate-ly 1 hour of battery life rem

ains.C

harge time: Less than 4 hours w

ith either sup-plied charger.

Operating environm

ent:32ºF (0°C) to 122ºF

(50°C) at <75%

RH

Storage environment:<80%

RH

meter and batt.

For 80% battery recovery:

-4ºF (-20°C) to 140ºF (60°C

) less than 1 month

-4ºF (-20°C) to 113ºF (45°C

) less than 3 months

-4ºF (-20°C) to 68ºF (20°C

) less than 1 yearPatents: #6,791,088 and #7,022,993

Accessories included:w

all charger, car charger,case, 10 extra filters, 5 spare O

-ring rubber gas-kets, battery (installed), and operator’s m

anual.

Quick Tips

1.K

eep the wand tip m

oving past suspected leaklocations.

2.O

nce a leak is detected, sweep the w

and backover to pinpoint.

3.To pinpoint larger leaks adjust sensitivity.

T2 T2P

EA

K

MU

TE

ON

/OFF

ON

/OFF

L/M/H

SENSITIV

ITYHML

PEAK

LOW-BA

TT

PRESS FO

R1 SEC

ON

D

SR

L2

InfraredR

efrigerantLeak D

etectorSEN

SITIVITY

HML

PEAK

LOW-BA

TT

WA

RN

ING

DO

NO

Topen battery com

partment or m

etercase. B

attery must be replaced by Fieldpiece.

DO

NO

Tcharge battery w

ith any other charg-er than those that cam

e with the instrum

ent!D

ON

OT

use the SR

L2 without the proper fil-

ter correctly installed. R

ead and follow the Lithium

Battery C

aresection in this m

anual.

!!

Operation

ON

/OFF Protection

To turn on/off the SR

L2 press and hold theO

N/O

FF button for one second. This slight delayprotects against inadvertant pressing. If you forgetto turn it off, it w

ill automatically go off in 10 m

inutes.

LEDB

ar Graph D

isplayThe eight segm

ent LED

display indicates thedegree of change

in refrigerant concentration. As

the concentration of refrigerant in the air increases,so does the num

ber of lit bars on the display.

L/M/H

Button (Sensitivity)

Set the sensitivity level by pressing the L/M

/H but-

ton. Low(L), m

edium(M

), or high(H) sensitivity w

illbe indicated by their respective LE

D.

Use the highest sensitivity that w

ill not give youfalse indications of a leak. The higher the concen-tration of refrigerant in the am

bient air, the lower the

sensitivity setting should be to minim

ize false trips.

Mute B

uttonP

ressing the MU

TE button toggles the sound of

the SR

L2 on and off.

Peak Button

The PE

AK

function holds the highest change inconcentration achieved w

hile continuing to detect

leaks. Press P

EA

K to toggle this function on and off.

Turning the PE

AK

function off will clear the peak

change. The PE

AK

LED

will light w

hen PE

AK

func-tion is on.

Leak Detection Procedure

Keep the S

RL2 aw

ay from any areas of potential

refrigerant leakage until the warm

-up and calibrationperiod

is over.

The w

arm-up

and calibration

sequence lasts about 30 seconds after ON

/OFF is

pressed. On startup, m

eter defaults to high sensitiv-ity.The m

ost likely points for refrigerant leaks are atthe soldered joints in refrigerant lines and changesin cross section or direction of these lines.

The SR

L2 detects changesin concentration of

refrigerant, not the absolute concentration of refrig-erant. This lets the user easily detect leaks in placesthat m

ay have refrigerant in the air, such as a refrig-erator leaking into an enclosed space. B

ecause theS

RL2 detects change, there is a specific “double-

pass” method used to find leaks.

1. The tip of the wand should be fairly close to the

line. You may need to be w

ithin 1/4” of a small

leak to detect it. In this case, using a secondhand to guide the tip along refrigerant lines m

aybe helpful.

2. Keep the tip m

oving along refrigerant lines at arate of 1-3 inches per second.

3. Once the S

RL2 indicates a change in concentra-

tion, note the spot on the line and keep the tipm

oving past the potential leak to refresh the airspace w

ithin the SR

L2 with clean air. (N

ote: Ifthe S

RL2 w

and moves through a very high con-

centration of refrigerant, you may need to use in

fresh air for 4 seconds before moving to step 4

in order to clear the refrigerant within the S

RL2.)

4. Return the tip back to, and past, the spot first

indicated. When the S

RL2 indicates a second

change, note the spot on the line. The source ofthe leak w

ill be near the midpoint betw

een thetw

o noted spots of indication. 5. Very high concentrations of refrigerant can

cause an overload which can take a few

sec-onds to clear.

Warranty and Service

The product is warranted to the original purchas-

er against defects in material or w

orkmanship for a

period of one (1) year from the date of purchase.

During the w

arranty period, Fieldpiece Instruments

will, at its option, replace or repair the defective unit. This w

arranty does not apply to defects resultingfrom

abuse, neglect, accident, unauthorized repair,alteration, or unreasonable use of the instrum

ent.A

ny implied w

arranty arising out of the sale ofFieldpiece's products including but not lim

ited toim

plied warranties of m

erchantability and fitness forpurpose are lim

ited to the above. Fieldpiece shallnot be liable for incidental or consequential dam

-ages.

Any

defective S

RL2

should be

returned to

Fieldpiece Instruments for w

arranty service alongw

ith proof of purchase. Call Fieldpiece for a return

material authorization (R

MA

). For out of warranty

service, send the SR

L2 meter w

ith battery installedalong w

ith an RM

Anum

ber. Your SR

L2 will be

repaired or replaced at Fieldpiece's option. Repair

price for SR

L2 meter is $155. R

epair price for SR

L2battery is $45. Fieldpiece Instrum

ents, Inc.580 W

est Central Ave. S

uite AB

rea, CA

92821P

hone: (714) 257-9060 Fax: (714) 257-9069w

ww

.fieldpiece.comS

RL2 testing an A

-coil in an evaporator, 1/4” from the line.

1/4”

Page 2: Operation Model: SRL2 Leak Detector Refrigerant Infrared ...€¦ · Leak Detector Model: SRL2 OPERATOR’S MANUAL Description The SRL2 uses infrared optics to create a portable refrigerant

More Products From

Fieldpiece

Modular

Expandability

Modular

expandability is

ability for

accessoryheads

and m

eters to

change configurations

tom

atch the various needs of an HVA

C/R

technician.A

ccessory heads (the sensors) send out a mV

signal, which represents the value of the m

easure-m

ent, to whatever m

eter is attached to it. Heads can

attach directly to the top of a Stick meter, D

L2 datalogger, or E

HD

L1. They can also plug into any meter

with m

V ranges using A

SLS

2 leads.

Stick Meter

This is the heart of modular expandability. In addi-

tion to being a full functioning multim

eter, any acces-sory head can be used w

ith it.

Model H

S36

Non contact voltage

Magnetic hanger

Autoranging

Backlight

Temperature

Volts, amps, ohm

sFrequency

Microfarads

Includes:H

S36 M

eterA

CH

4 Current C

lamp

ATB1 K

-type TCouple

AD

LS2 D

eluxe LeadsA

NC

1 Case

Accessory H

eadsA

ccessory heads are the sensors of multiple

parameters m

easured by technicians every day.They plug into a m

V range (depending on the head)

of a multim

eter. The multim

eter will display w

hatev-er the head is m

easuring. Instead of having to pur-chase and carry a separate instrum

ent for eachparam

eter, a technician can use multiple heads and

a single multim

eter to do the job.

Here are four of the m

any heads available:A

AV3 A

ir Velocity and Temperature

AD

MN

2 Dual-P

ort Manom

eterAV

G2 D

igital Vacuum G

augeA

OX

2 Com

bustion Check

Standalone Instruments

The SR

L2 is a standalone instrument for leak

detection. Accessory heads do not hook up to it.

Below

is a sampling of other standalone (non-m

od-ular) instrum

ents available from Fieldpiece.

SM

G5 M

egohm M

eterS

T4 Dual Tem

perature Thermom

eterS

RP

M2 O

ptical Laser Tachometer

SS

X34 S

uperheat and Subcooling for A

C &

Ref.

CA

T.III

300V

400A

CL

AM

P

AC

H4

AC

Current

Clam

p1A

AC

/ 1mVA

C400A

AC

MA

X

!

AirVelocity

&Tem

perature

Head

English

READ

LOBATT

ON

LCD

X100

Average(16

sec)

MetricReal

time

AAV3

AUTO-OFF

English

Metric

Ft/min

M/sKM/hr

MPHºF

ºCOFF

AOX2

CombustionCheck

%O%COTEMP

ON

GAS

OIL

Lo Batt

°C °FAUTOOFF

STABLE

Fuel Type

2

2

T/CCAL

AUTO-

OFFT/CCal

STA

BLE

Pr essure

Temp

SHor

SC

ONLO

BATT

Refriger

a tion

Superheat

andSubcooling

ENGLISHMETRIC

R134A

R404A

SetATM

ASX24

SH

SC

Air

Velo

city

&Tem

pera

ture

Head

En

glis

h

RE

AD

LO

BA

TT

ON

LC

DX

10

0

Av

era

ge

(16

se

c)

Me

tricR

ea

ltim

e

AA

V3

AU

TO

-O

FF

En

glis

hM

etric

Ft/m

inM

/s

KM

/hr

MP

HºFºC

OF

F

AD

MN

2

Dual-Port

Manom

eterA

ccessoryH

ead

P1

P2

P1-P

2

ON

0.1

EN

GL

ISH

ME

TR

IC0.0

1

(LC

D/1

0)

Lo

Ba

tt

Resolution

ZERO

AU

TO

OFF

P1

P2

aaaaa

aaaaa

aaaaa

aaaaa

aaaaa

aaaaa

aaaaa

aaaaa

AO

X2

Com

bustionC

heck

%O

%C

OT

EM

P

ON

GA

S

OIL

Lo

Ba

tt

°C °F

AU

TO

OFF

STA

BL

E

Fuel Type

22

T/CC

AL

Laser Digital Tachom

eter

Mode

Mem

ON

SR

PM

2 TEST

T2 T2A

TM

ON

/OFF

TY

PE

TE

MP.

UN

IT

KSHSC

ST

4

T1

T2

OFFS

ET

ON

OFF

T1-T

2

T1

T2

T2

1/0

.1º

ºT

ºC

/F

Min

/Max

T2

HO

LD

ºFT

1

v17

Lithium

Battery C

areThe S

RL2 contains a very pow

erful two-cell lithi-

um ion polym

er battery. For a long battery life andsafe operation you m

ust observe the following:

Cautions

1. Charge only w

hile battery is inside the SR

L2w

ith a Fieldpiece supplied charger. Do not

charge externally. 2. D

o not expose the battery to temperatures high-

er than 140ºF. 3. D

o not charge the battery in or nearby heatedplaces, such as fire, hot vehicles, or direct sun-light.

4. Do not directly connect the battery to any bat-

tery charger. The included chargers connect tothe S

RL2, not the S

RL2 battery.

5. Do not solder directly on battery.

6. Do not use the battery for unspecified equip-

ment.

7. Do not expose the battery to direct im

pact orthrow

it. If the protection circuit on the battery isbroken, do not continue to use the battery.

8. Do not get the battery w

et.9. D

o not deform or pierce the battery in any w

ay. 10. If there is any battery leakage, do not touch

the battery. In the case that electrolyte gets intothe eyes, flush w

ith fresh water, do not rub, and

see a physician imm

ediately. 11. S

end in for replacement im

mediately if there is

any deformity, bad sm

ell, color change, or otherabnorm

ality.12. D

o not dissassemble or try to repair battery or

protective circuitry.13.The battery is technician-replaceable and m

ustbe sent to Fieldpiece Instrum

entsif a replace-

ment is needed. It is not user-replaceable.

ChargingTw

o chargers are included with the S

RL2. The

AC

charger plugs into a wall outlet (110-120 VA

C,

60Hz) and the car charger plugs into a car cigarette

lighter DC

plug.1. The battery is partially charged w

hen packaged.Fully charge the battery before first use.

2. The LOW

-BATT

LED

will light red w

hen the bat-tery is low

. 3. To recharge the S

RL2, plug one end of the

charger into the top of the SR

L2 and the otherinto the pow

er source. LOW

-BATT

will blink

while charging until the battery is fully charged.

When the S

RL2 battery is fully charged, LO

W-

BATT

turns off. 4. C

harge within operating environm

ent specifiedin the Specifications section in this m

anual. 5. Avoid frequent full discharges. S

everal partialdischarges w

ith frequent recharges are betterfor lithium

-ion batteries. Unlike nickel-based bat-

teries they have no charge mem

ory, and do notneed to be discharged before charging.

StorageThe battery should have a 40%

-50% charge dur-

ing prolonged storage of a month or longer. S

eeSpecifications section in this m

anual for proper stor-age environm

ent. B

attery life is dramatically reduced if the battery

is stored fully charged and/or at high temperatures.

Carrying C

ase W

hile both chargers fit in the included case, thecarrying case is intended to carry the leak detectoralone. M

ost users leave the chargers near thepow

er supply and carry around just the meter.

Larger cases, to hold both chargers plus extraaccessories, are available such as the A

NC

8 (seeO

ptional Accessories).

FilterAssessm

ent & R

eplacement

The filter blocks moisture and other contam

inantsfrom

the sensor. When it gets w

et, it constricts flowof air and it w

ill have to be replaced.Unscrew

thesensor tip and replace the w

hite filter so that therounded end is closest to the tip of the w

and. Use

only the Fieldpiece supplied filter. E

xtra bags of replacement parts (m

odel RFL2)

are available from Fieldpiece w

hich contain 10filters and 5 O

-rings.

Optional A

ccessoriesU

se model R

RE

2 when detecting in tight spaces,

such as through a condensor grille. Model R

FE2

extends the wand to 25.5”. The m

idsize case,m

odel AN

C8, holds everything w

ith room to spare.

9” Needle Tip P

robem

odel RR

E2

9” Flex Extension

model R

FE2

4 Pocket M

idsize Case

model A

NC

8