Drainage systems may be used to drain fluid, mostly blood, from surgical wounds after an operation.
Low Vacuum
Passive Drainage
High Vacuum (except close to intestine and glands)
CONFIDENTIAL & PROPRIETARY
5
A key element in infection control and in facilitating the healing and mobilization process.
Why do we need wound drainage?
The process of facilitating and collecting post-operative bloodshed in order to avoid haematomas.
Without drainage the fluid;• Is a medium for infection• Prolongs the healing process• Causes pain to the patient
CONFIDENTIAL & PROPRIETARY
6
The ideal wound drainage system
Removes blood effectively
Reduces the risk of wound infection
Gentle to the tissue
CONFIDENTIAL & PROPRIETARY
7
What Are Wound Drainage Systems?
A sterile, single-use medical device consisting of:-
•Catheter – different types, sizes, materials (PVC or Silicone)• Trocar (usage optional)• Connecting Tube• Receptacle – Bottle / Bag• Bellows
CONFIDENTIAL & PROPRIETARY
8
Where are they used?
Predominantly where surgical procedures are performed;• Theatres – All specialities• Day Surgery Units• Recovery
Wards will need to have stock of spare receptacles for replacement
CONFIDENTIAL & PROPRIETARY
9
Types of Drainage Systems
Low vacuum• HandyVac™ System• UnoVac™ System• MiniVac™ System
Initial vacuum pressure • 50 – 120mmHg
CONFIDENTIAL & PROPRIETARY
10
HandyVac™ System: Low vacuum system
CONFIDENTIAL & PROPRIETARY
11
Bag
Drain
Trocar
Bellows
Hanger
ClampConnector
HandyVac™ System
700 ml
125 ml
With/withoutbottom outlet
CONFIDENTIAL & PROPRIETARY
12
Non-Return Valves – infection prevention
Non-ReturnValve
No reflux of fluids
CONFIDENTIAL & PROPRIETARY
13
Suction Efficiency
Excellent suction curve (in-vitro) - 25/65 mmHg• Minimises risk of hole closure• Minimises risk of tissue damage• Used for head, back and
abdominal surgery
Data on file. Test report: Suction pressure as a function of suction amount. 26 th September 2007.
CONFIDENTIAL & PROPRIETARY
Suction Pressure as a Function of Suction AmountHandyVac System with 700 ml bag. Ref nr. 400977182
14
HandyVac™ System
Low vacuum drainInitial vacuum pressure
• 65mm HgBellows capacity
• 125ml Bag
• 700mlDrain Sizes
• Ch 8,10,14,18Bags with or without tapsTwo non-return valves (NRV)
• Bag NRV prevents reflux • Drip chamber NRV
– eliminates need for clampsRedon spiral drain
CONFIDENTIAL & PROPRIETARY
15
HandyVac™ System Competitors
Bellovac™ System
Exudrain™ Mini System
Abdovac™ System
CONFIDENTIAL & PROPRIETARY
Author
Are these competitors up to date?What are the full names of the products?
16
HandyVac™ System Competitors
Redax™ SystemRedax™ Silicone System
LowVac™ Plus System
CONFIDENTIAL & PROPRIETARY
17
The UnoVac™ System
CONFIDENTIAL & PROPRIETARY
18
Bag
Bellows
Trocar
Ulmer drain
Protective cap
Filter
600 ml
300 ml
UnoVac™ System
CONFIDENTIAL & PROPRIETARY
19
How to establish the vacuum
Press with two thumbs No clamps needed
Simple and time saving
CONFIDENTIAL & PROPRIETARY
20
Non-Return Valves – Infection prevention
2 Non-Return Valves
CONFIDENTIAL & PROPRIETARY
21
What are the advantages of the UnoVac™ System?
Low or passive drainage Supplied as a closed hygienic system With profuse secretion it is possible to change the bag Constant suction level Easy visual control of remaining vacuum High capacity of 900 ml ( bellows 300 ml / bag 600 ml)
CONFIDENTIAL & PROPRIETARY
22
Start
Almostfull
Passive drainage
Suction Efficiency
Excellent suction curve (in-vitro) - 110/95 mmHg to 50/60mmHg• Minimises risk of hole
closure• Minimises risk of tissue
damage• Suction Peak- almost full
Data on file. Test report: Suction Curves at 15 ºC and 25 ºC . 6 th February 2001.
CONFIDENTIAL & PROPRIETARY
Suction Pressure as a Function of Suction AmountUnoVac™ System
Used primarily in • Faciomaxillary (MaxFax)• Head & Neck surgery • Hand surgery
CONFIDENTIAL & PROPRIETARY
24
MiniVac™ System Competitors
Mini-Exuvac™ System (Minimed/procar3e/GB-UK)
Exudrain™ Mini System (Astratech)
Red-0-pak™ System (Vygon)
Mini Redovac™ System (B.Braun)
LOW VAX™ System (Athrodax)
CONFIDENTIAL & PROPRIETARY
25
High Vacuum
CONFIDENTIAL & PROPRIETARY
26
High Vacuum System
Initial vacuum pressure • Above 400mmHg
600ml bottle • Drain sizes Ch 10,12,14,16,18
400ml bottle • Drain sizes Ch 10,12,14,16
Non Return Valve • 600ml bottles only
Redon spiral drain
CONFIDENTIAL & PROPRIETARY
27
High Vacuum - Competitors
Redovac™ System (B.Braun)PREVAX™ / Econovax™ Systems (Athrodax)Drenofast™ (Nikomed)Safe-t-Vac™ System (Pro-Care/Minster/Meddis/GB-UK)Medinorm™ System (Summit)
CONFIDENTIAL & PROPRIETARY
Author
Again, are brands/manufacturers up to date?
28
Passive drainage
PassiveNo negative pressure
• gravity only (25mmHg) Ulmer drain Soft 90cm tube 700ml drainage bag Sizes Ch 20,24,28
Single use solid trocarPVC or Silicone drainsDifferent perforationsDetectable X-ray lineBlack indicator marks
CONFIDENTIAL & PROPRIETARY
32
Spiral drain
Redondrain
Corrugated drain
Slit drain
Ulmer drain Silicone drain
Wound Drain Perforations
CONFIDENTIAL & PROPRIETARY
33
Silicone vs. PVC
Silicone is inert (does not react with tissue),soft and pliable. Enviromental issues with PVC – clorinated by-products of incineration. Silicone: the most researched and tested material for implantable applications.
CONFIDENTIAL & PROPRIETARY
34
Multiple narrow ducts provide fluid entry at any point
Radiopaque
Flat Drain
CONFIDENTIAL & PROPRIETARY
35
Features of Round Drains
Four continuous channels providegreater tissue contact area than regular perforated drains
Constructed of silicone with solidcenter designed for strength andflexibility
Offers multiple drainage routes to resist clogging
Smaller, more flexible tube
Due to channel design, removal may beless traumatic to surrounding tissues incomparison to designs with holes
CONFIDENTIAL & PROPRIETARY
36
Various
Flexible Yankauer
Standard
Filter Flow System
OP-Flex™ Range of Suction Systems
CONFIDENTIAL & PROPRIETARY
37
Suction in Surgery
CONFIDENTIAL & PROPRIETARY
38
Why is suctioning neeeded in surgery? During operations it is necessary to remove blood and fluid in order to maintain an unobstructed view of the operating are and organs.
The surgeon uses suction handles (linked to vacuum) of different kinds to keep the area free of blood and fluids to have a clear view of the surgical field.
The production of a vacuum or partial vacuum in a cavity or over a surface - so that the external atmospheric pressure forces the surrounding fluid or blood, into the suction handle – through the tubing to the canister on the floor.
CONFIDENTIAL & PROPRIETARY
39
The handle is THE tool for the surgeon
CONFIDENTIAL & PROPRIETARY
40
An operation suction set consists of a suction handle and a connecting tube.
The connecting tube is connected to a canister which can be either reusable or disposable.
The canister is connected to a vacuum source having a vacuum of 2-400 mmHg mm/Hg
How does a vacuum source work?
CONFIDENTIAL & PROPRIETARY
41
Historic Overview - Yankauer
Developed approximately 1907 by Dr. Charles Yankauer, the Yankauer Suction Instrument has become the most common suction instrument in the world. It's primary use is to aspirate fluid and debris from either a surgical site or orifice, e.g. the mouth.
CONFIDENTIAL & PROPRIETARY
42
Yankauer Tips
Conventional yankauer – all surgeries Tapered yankauer – narrow cavities Flattened yankauer – between nerves and muscle fibres Sump yankauer – delicate tissue Super Flow – AAA or trauma Poole – delicate tissue
CONFIDENTIAL & PROPRIETARY
43
OP-Flex™ Suction Handles
CONFIDENTIAL & PROPRIETARY
Tapered
Conventional
Flattened
Sump
Poole
44
OP-Flex™ Range
ErgonomicSuction handle
With/withoutVacuum control
Detachable – easy to change Different tips
available
CONFIDENTIAL & PROPRIETARY
45
OP-Flex suction handles are supplied both with and without vacuum control
When the hole is uncovered there is no suctioning.
When the hole is covered suctioning takes place.
CONFIDENTIAL & PROPRIETARY
46
Detachable Handles
CONFIDENTIAL & PROPRIETARY
47
Relieving eyes
Designed to minimise the risk of tissue damage
Relieving Eyes
CONFIDENTIAL & PROPRIETARY
48
OP-Flex Connecting Tube
Anti-kink connectors • Unrestricted flow through the system• Full maneuverability in all positions.• Cut -to-fit connector at the distal end
to enable a fit to all canisters
CONFIDENTIAL & PROPRIETARY
49
Anti-kink Connector
Unrestricted flow through the system with no risk of stopping the suctioning due to kinking.Full maneuverability in all positions which is very important as the surgeon will often have very limited space
CONFIDENTIAL & PROPRIETARY
50
To enable a fit to all canisters
Cut-to-fit Connector - Universal
CONFIDENTIAL & PROPRIETARY
51
Flexible bendable tipPrecise handling & maximizes protection of internal organs.
Integrated basketIncreases the safety of loosing the tip.
Transparent materialEasy observation of blood.
Ergonomic handleNon-slip safe-grip groove.
Integrated universal connectorSecures firm connection to suction tube.
OP-Flex™ Flexible Yankauer Handle
CONFIDENTIAL & PROPRIETARY
56
Tyco
Dahlhausen
Pennine
Astra
Competitors
58
The OP-Flex™ FilterFlow Suction Set
CONFIDENTIAL & PROPRIETARY
59
What is included in the Op-Flex™ FilterFlow Set?
FilterFlow handle containing a filter.One extra filter included.3 tips packed in set
•1 short bent •1 long bent•1 long straight
Indication Intra femoral suctioning.OP-Flex connecting tube.
Single packed filters are available in boxes of 20
CONFIDENTIAL & PROPRIETARY
60
Patented filter system prevents inconvenient and time-consuming blockages.
The patented cross-flow filter allows fluids to pass through with minimal damage, yet traps debris that could clog conventional suction sets.
FilterFlow Filter
CONFIDENTIAL & PROPRIETARY
61
MalleableTip with stylette
X-Ray line
2 different lengths
Graduatedconnector
The OP-Flex™ Frazier Suction Handle With/without
Vacuum control
CONFIDENTIAL & PROPRIETARY
62
Where are Frazier Handles used?
Neurological surgery Plastic surgery Cardiac surgery Ear-Nose-Throat Other operation field where a small suction handle is used to access
CONFIDENTIAL & PROPRIETARY
63
Close up features
Flexible due to the stylette
Vacuum control Easy to connect to tubing
CONFIDENTIAL & PROPRIETARY
64
Disarp™ - Disposable Abdominal Retracting Pad
Unique UnoMedical product X-ray detectable 45 cm and 25 cm lengths
The Disarp™ Device was developed to protect and retract soft tissue during surgery in order to keep the operating field visible, clean and free of blood and fluids.
CONFIDENTIAL & PROPRIETARY
65
Benefits of the Disarp™ Device
Can be bent into desired position. Can be placed in small areas in the operation field. Excellent absorption of blood and fluids. X-ray detectable.Absorption capacity of short Disarp 100ml. Absorption capacity of long Disarp 200ml.