Page 1: Operating Instructions - VETTER Permanent Aspirator

Emergency Pneumatics.

Operating InstructionsVETTER Permanent Aspirator

Article No. 9987011205 | © Vetter GmbH I 06/16 I Changes and errors excepted.

Page 2: Operating Instructions - VETTER Permanent Aspirator

Page 2/20

Vetter Permanent Aspirator

Contents

1. Important preliminary remarks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3

2. Description of the product . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3

2.1 Scope of delivery . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3

2.2 Optional accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4

2.3 Area of application . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4

2.4 Correct use according to regulations . . . . . . . . . . . . . . . . . . . . . . . .4

2.5 Safety information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4

3. Preparing the product for use . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5

3.1 Preparations for operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5

3.2 Emergency switch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5

4. Operating instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6

4.1 Operation mode: Suction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6

4.2 Operation mode: Pump . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6

4.3 Operation mode: Suction and Pumping . . . . . . . . . . . . . . . . . . . . .6

4.4 Aspiration of strongly contaminated liquids . . . . . . . . . . . . . . . . .7

4.5 Care and maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7

5. Taking the product out of operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7

6. Elimination of defects . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8

7. Technical data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9

8. Spare parts lists . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10

8.1 Motor head . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11

8.2 Adapter with cover and pump holder . . . . . . . . . . . . . . . . . . . . . 13

8.3 Suction line . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14

8.4 Pump with pressure line . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15

8.5 Switch panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16

8.6 Suction hose . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17

8.7 Suction pipe, stainless steel (2 parts) . . . . . . . . . . . . . . . . . . . . . . 17

8.8 Narrow space nozzle . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17

8.9 Ground nozzle 370 mm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17

8.10 Trolley for Permanent Aspirator, GF-Polyester . . . . . . . . . . . . . . 18

9. Resistance Guide . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18

EC Conformity Declaration (available on request) . . . . . . . . . . . . . . . . . . . 19

Page 3: Operating Instructions - VETTER Permanent Aspirator

Page 3/20

1. Important preliminary remarks

Only a knowledge and exact adherence to this operating manual will guarantee correct and perfect operation, achieve the best possible use and uphold claims made within the framework of the Vetter warranty.

Vetter Permanent Aspirators must only be used by trained, reliable staff. Operational usage of the Permanent Aspirator is to be made under the condition that operators have an exact knowledge of this operating ma-nual and that they observe all the information contained in it.

The operating instructions given here are to be regarded as part of the product and are to be kept for the complete life duration of the product. In case the product should be passed on to a successive user then the operating instructions must also be included.

2. Description of the product

2.1 Scope of delivery

Article No. Description Qty.

2210001303 Permanent Aspirator setbasic equipment consisting of:

2210001101 Suction and pump unit 1

2230004500 Container, 100 l, GRP-Polyester 1

2230010501 Filter cage 1 1/2" OT 1

2230022900

Accessories aspirators, consisting of:Suction hose, oil resistant, 6 m, incl. curved connecting pipe and adapter suction hose, blue incl. coupling Storz 38 Suction pipe (2 parts) Narrow space nozzle Ground nozzle

1

2230001100 Trolley, GRP-Polyester 1

Page 4: Operating Instructions - VETTER Permanent Aspirator

Page 4/20

Vetter Permanent Aspirator

2.2 Optional accessories

Article No. Description

2230025400 Safety switch PRCD-S

If in an exceptional case it is necessary to provide the power sup-ply from other feed points (external network, e.g. public power supply), the fire brigade accident prevention regulations stipulate the use of PRCD-S type portable residual current devices.

2.3 Area of application

The Vetter Permanent Aspirator can be used for the aspiration of water, oil and non-aggressively acting liquids. Both mobile and stationary operation is possible depending on the task involved.

2.4 Correct use according to regulations

The mains power supply line is to be protected against damage. The aspirator is only allowed to be used when the connection line is in a perfect condition. The aspirator is set to a operating voltage of 240 V/ 50 Hz at the manufacturer.

The mains power plug is to be removed before any cleaning, maintenance and repair work is carried out.

2.5 Safety information

All pertinent, public work protection and accident prevention re-gulations are to be observed as well as the generally recognized regulations for the field of technology. The necessary work pro-tection clothing is to be worn during operation.

Attention! Danger of Explosion!Vetter Permanent Aspirators are not protected against explosion owing to their operational principle (vacuum cleaner).

It must not be used for aspiration of highly inflammable liquids or liquid mixtures (with a flash point below 21°C). Vetter Permanent Aspirators must not be used in Explosion Protected Zones (0).

Explosion Protected Zones are, according to the German Regula-tions for inflammable Liquids (German abbreviation: VbF), explo-sion endangered areas in which there is a constant or permanent explosive atmosphere caused by inflammable gasses, vapours or mist.

All Vetter Permanent Aspirators are suitable for liquid aspiration.

Never turn on with gloves or other insu-lating materials.

Page 5: Operating Instructions - VETTER Permanent Aspirator

Page 5/20

Acids, caustic solutions and aggressively acting solvents can form mixtures which are a danger to health and therefore must not be aspirated.

Dust cannot be aspirated with the Vetter Permanent Aspirator. In agreement with the Trade Association we would like to expressi-vely point out that in this connection, this aspirator must not be used for the aspiration of dust and dust which is hazardous to health.

3. Preparing the product for use

3.1 Preparations for operation

Place the container into the trolley if there is a trolley available for mobile operation. When using the adapter make certain that the adapter sealing on edge of the container seals correctly. Use the filter cage when aspirating.

Connect the pressure coupling (Storz C) to the blocking valve. It is to be opened before pumping begins and closed when pumping has finished. This stops the pumped liquid from flowing back after pumping has finished.

In order to pump out, connect a normal fire service hose having a Storz C coupling to the blocking valve Size C. Lay out the hose so that it is not bent. The fire service hose should not be longer than necessary to achieve maximum pump performance. Check to see if the motor head is perfectly seated in the adapter opening.

Connect the suction hose to the suction coupling for suctioning off. Connect the bent pipe first and then connect the 2-part suc-tion pipe to the previously mounted suction hose. Depending on the type of use, push the ground nozzle or the narrow crevice nozzle onto the suction pipe. Connect the mains power plug to a correctly installed protection contact socket.

3.2 Emergency switch

The Permanent Aspirator is equipped with an emergency switch according the regulations from the German Association for Elec-trical Engineering (VDE). If the emergency switch is activated be-fore work begins then it can be deactivated by turning in the di-rection of the arrow (clockwise).

Page 6: Operating Instructions - VETTER Permanent Aspirator

Page 6/20

Vetter Permanent Aspirator

4. Operating instructions

4.1 Operation mode: Suction

Set the „ASPIRATOR“ switch on the panel to „ON“ and leave the „PUMP“ switch set to „OFF“. The blocking valve, Size C, remains closed.

The liquid is suctioned. When the container reaches full capaci-ty, the swimmer ball will block the suction opening of the motor head. The suction sequence is interrupted. Switch the equipment „OFF“ using the „ASPIRATOR“ switch. Empty the tank or pump out at another position.

4.2 Operation mode: Pump

Only pumping out takes place, the suction turbine remains swit-ched off. Connect the pressure hose, making sure it has no bends, to the blocking valve (Size C). Set the „PUMP“ switch on the panel to „ON“. Open the blocking valve (Size C). The container is now au-tomatically emptied. The dredging pump automatically switches off after completion of the emptying process. Set the „PUMP“ switch to „OFF“- Close the blocking valve (Size C) and decouple the pressure hose.

4.3 Operation mode: Suction and Pumping

Connect the pressure hose as described before and open the blo-cking valve (Size C). Set both switches to „ON“. The liquid is suc-tioned and pumped out at the same time. The dredger pump is automatically switched on and off by the swimmer switch depen-ding on the level of liquid in the container.

With large feed amounts, the capacity for the suctioned liquid exceeds the pumping capacity: The swimmer ball then closes the suction opening of the motor head. The suction sequence is automatically interrupted.

Switch off the suction turbine by setting the „ASPIRATOR“ switch on the panel to off. Due to the fact that the liquid is further pum-ped, the swimmer ball is released after a short time (about 15 secs) from the suction opening of the motor head. Switch on the motor head again. The suction capacity is to be matched to the feed ca-pacity by feeds over 4 m. To do this, proceed as follows:

1.) Withdraw the ground nozzle out of the liquid to be suctioned before the container is filled and the swimmer ball closes the suction opening. Only pumping takes place.

or:

Page 7: Operating Instructions - VETTER Permanent Aspirator

Page 7/20

2.) Interrupt the suction sequence by briefly switching off the suction turbine if the level is the same. By doing this, the pumping sequence is not interrupted. Switch the suction tur-bine on again as soon as the level of liquid in the container has correspondingly sunk.

4.4 Aspiration of strongly contaminated liquids

The Permanent Aspirator is equipped with a collection filter cage in order to protect the feed pump. To empty the filter cage, turn it counter clockwise and take it out of the holder. Empty the filter cage and re-insert. Remember that with strongly contaminated li-quids it should be regularly emptied because if it is full it will grea-tly reduce the suction power.

4.5 Care and maintenance

Any special maintenance measures are not required owing to the sturdy construction of the Vetter aspirator. The suction hoses are not, under any circumstances, to be cleaned with a hot water high pressure cleaner, as for example can be done with the containers.

The motor head with the suction turbine is maintenance-free and does not therefore require any special maintenance.

5. Taking the product out of operation

The disposal of used electrical and electronic equipment (ap-plicable in the countries of the European Union and other Euro-pean countries with a separate collection system for these items) in accordance with the electrical and electronic equipment act (ElektroG) of 24th March 2005, implementing the EC guidelines 2002/96/EC on electrical and electronic equipment (“WEEE gui-delines“).

This symbol on the product or its packaging means that the electronic components of this product are not to be treated as normal household waste but must be returned to the manufac-turer for recycling (free delivery).

Page 8: Operating Instructions - VETTER Permanent Aspirator

Page 8/20

Vetter Permanent Aspirator

6. Elimination of defects

Defect Cause Remedy

Suction motor does not run

Shut-off switch is off Turn the switch on. Call a qualified electician if switch cuts off again.

No mains voltage Check socket

Connection cable defective Replace cable*

Motor is defective Exchange motor*

Emergency switch is pressed

Unlock the emergency switch

Suction motor runs but equip-ment does not suction

Float ball has closed the suction opening

Switch off motor, re-lease float ball

Suction line is blocked Clean suction line

Motor head turbine is defective

Carry out maintenance*

Conveyor pump power is too low

Pump is blocked Clean pump

Conveying height is too high

Reduce height diffe-rence

Suction motor runs but suction power is too low

Equipment is drawing air from outside

Check the adapter and motor head for correct seating

Sealing is defective Exchange sealing

Suction line is blocked Clean suction line

Suction height is too great Place the equipment to suction level

Filter basket is blocked Empty filter basket

Conveyor pump does not work

Float switch is interlocked Release float switch

Connection cable defective Replace cable*

Pump wheel blocked by dirt Clean pump and wheel

Pump motor defective Exchange pump*

Conveyor pump runs but there is no feed

Pump blocked Clean pump

Ventilation hole blocked (in the lifting tube of the pump under the flap trap or at the side of the pump)

Clean ventilation hole

Pressure hose is bent Take out the bend in the hose

Shut-off unit Size C is closed Open shut-off unit

Pump is defective Exchange pump**only by a qualified electricianShould the defect remain despite the above information then contact an authorized representative or Vetter GmbH.

Page 9: Operating Instructions - VETTER Permanent Aspirator

Page 9/20

7. Technical data

Set Permanent Aspirators Art.-Nr: 2210001303

Unit Data

Suction power (air)l/min. 3,030

cu.ft./min. 107

Suction power (water)l/min. 160

cu.ft./min. 5.7

Vacuum pressuremm WS 2,392

psi 3.5

Delivery capacity of pumpl/min. 260

cu.ft./min. 9.2

Delivery height of pumpm 11

ft. 18

Current consumption of motor head Amps 4.6

Current consumption of pump Amps 3.4

Power consumption of motor head Watts 1.000

Power consumption of pump Watts 800

Voltage of motor head * V/Hz 240/50/60

Voltage of pump * V/Hz 240/50

Capacity of containerl 100

cu.ft. 3.53

Dimensions of aspirator base equipment (LxWxH)

cm 86 x Ø 62

in. 34 x Ø 25

Weight (set for base equipment), ca.kg 35

lbs 77

Noise level dBA 84.9

Protection class : IProtection category : IP 44

All rights reserved for technical changes within the scope of product improve-ment.

Page 10: Operating Instructions - VETTER Permanent Aspirator

Page 10/20

Vetter Permanent Aspirator

8. Spare parts lists

1

2

3

4

5

1. Motor head with suction turbine

2. Adapter with cover and pump holder

3. Pump with pressure line

4. Suction line

5. Switch panel

Page 11: Operating Instructions - VETTER Permanent Aspirator

Page 11/20

8.1 Motor head

Page 12: Operating Instructions - VETTER Permanent Aspirator

Page 12/20

Vetter Permanent Aspirator

Pos.: Article No. Description Qty.

2 2220 0002 00 Turbine upper housing cover 1

3 2220 0003 00 Turbine upper housing, blue 1

4 2230 0073 00 Pan-head tapping screw, cross headed 3

5 2220 0004 00 Securing ring, PVC 1

6 2230 0074 00 Turbine 1000 Watt, 240 Volt 1

7 2230 0064 00 Capacitor 800/1000/1200 Watt BV 0.450/60 1

8 1700 0045 00 Slotted screw M 5 x q16, galv. DIN 84 2

9 2230 0066 00 Securing clip for capacitor, 16 mm diam. 1

10 2230 0077 00 Insulation disk, ST 37, diam. 190 mm x 102 mm 1

11 2230 0078 00 Rubber sealing ring 195/245 diam. x 15 1

12 2230 0079 00 Sealing made of cellular rubber, black 140x59x4 mm 1

13 2230 0080 00 Turbine head 1

14 2230 0081 00 Pan-head tapping screw, cross headed, 4.8 x 50 6

15 2230 0082 00 Wire cloth (1.4301), machine width 6.3 mm 1

16 2230 0083 00 Sealing rubber for turbine head 1

17 2230 0148 00 Sealing 150x59x4mm, 130 mm, 8 holes 8 mm 1

18 2230 0067 00 PVC plate for PG screw, gray 1

19 2230 0002 00 Sponge rubber ball 1

20 2230 0086 00 Cable screw fitting BS 11 1

21 2220 0001 00 Swimmer ball housing 1

22 1481 0097 00 U-washer 12.0 x 6.4 x 1.6 mm, stainless steel A2 9

23 2230 0053 00 Screw M 6 x 12, A 2, DIN 933 8.8 7

24 2230 0085 00 Sealing made of cellular rubber, black 140x100x4 mm 1

26 2230 0076 00 Counter sunk screw, cross headed 3.5x9.5 DIN 7982 2

27 2230 0032 00 Cable HO7 RNF 3G 1.5, product sold by meter 0,8

29 1700 0174 00 Core end sleeves, insulated, 1.5 sq mm- 8mm red 2

30 2230 0126 00 Cable shoe 1 mm 6

31 2230 0107 00 Pan-head tapping screw, cross headed, 4.2 x 19 4

32 2230 0102 00 PVC plate for covering switch, gray, 27x38x3mm 1

34 2230 0108 00 Toothed disk, internal tooth DIN 6798 4

35 2230 0068 00 Ground cable SIF 1.5 GR/YEL, meter 0,3

38 2230 0087 00 Label „Motorkopf Gerätetyp“ 1

39 2230 0071 00 Protection conductor label 1

40 2230 0003 00 Butt joiner 2

41 1700 0172 00 Shrink fit sleeve 142/21-064 DN 06 3:1 PB, meter 0,12

42 2230 0120 00 Flat sleeve, red 0.5 qmm-1 sq mm /6.3x08 1

43 1700 0351 00 Label "Elektroschrott" 1

45 2230 0054 00 Nut m 6, A2, DIN 934 1

45 1700 0212 00 Nut M 6, self-locking, A2 1

2230 0121 00 Thread rod M 6, V2A 0,03

Page 13: Operating Instructions - VETTER Permanent Aspirator

Page 13/20

8.2 Adapter with cover and pump holder

2

1

3

45

678

910

6-10

11

Pos.: Article No. Description Qty.

1 2210 0009 01 Adapter-PA, GRP, 4 layer, bare 1

2 2210 0002 00 Pump cage for Permanent Aspirator 1

3 2230 0100 00 Leaf spring 15 x 0.6 mm, Z-Form, raw, blank 3

4 2230 0018 00 Slotted screw M 4 x 12 6

5 1700 0170 00 Nut M 4, self locking 8

6 2230 0043 00 Screw M 8 x 50 4

7 2230 0023 00 Washer 20x8.5x1.5 mm 9

8 2230 0038 00 Rubber squeeze nipple 9

9 1700 0168 00 Nut M 8 6

10 2230 0044 00 Nut M 8, self locking 4

11 2230 0030 00 Label " PA " 1

Suction line

1

Pressure line

Pos.: Article No. Description

1 2230 0005 00 Foam rubber sealing ring 1.85 m

Page 14: Operating Instructions - VETTER Permanent Aspirator

Page 14/20

Vetter Permanent Aspirator

Grounding cable/Adapter/Pump cage

4 - 5

1

2

3

4 - 5

23

1

Pos.: Article No. Description Qty.

1 2230 0175 00 Eyelet for grounding cable 2

2 2230 0176 00 Winch wire 0,54

3 2230 0177 00 Cable lug 6

4 2230 0178 00 Hexagon screw 4

5 1700 0212 00 Nut M 6, self locking, A 2 4

8.3 Suction line

21

3

4

5

Pos.: Article No. Description Qty.

1 2230 0039 00 Fixed coupling Storz 38, 1 1/4" AG 1

2 2230 0035 00 Angle 90°, 1 1/4" IG, brass 1

3 2230 0175 00 Eyelet for grounding cable 1

4 2230 0037 00 Double nipple 1 1/4" AG, brass 1

5 2230 0149 00 Reducing sleeve 1 1/4" IG - 1 1/2" IG,brass 1

Page 15: Operating Instructions - VETTER Permanent Aspirator

Page 15/20

8.4 Pump with pressure line

2

1

34

5

6 7

8

9

10

12

13

11

6

8

14151617

Pos.: Article No. Description Qty.

1 2230 0050 00 Automatic drainage immersion pump 1

2 2230 0150 00 Angle 90°, 1 1/4" AG-AG 1

3 2230 0055 00 Pipe clamp A2, 20/1. rubber 1

4 1700 0168 00 Nut M 6, A2 6

5 1481 0098 00 Locking screw M 8 x 30 1

6 2230 0110 00 Hose clamp SG 12 mm/32-50 2

7 2210 0003 00 PVC hose 38x5 mm,transparent 0,37

8 2230 0037 00 Double nipple 1 1/4" AG, brass 3

9 2230 0052 00 Nonreturn clap 1

10 2230 0175 00 Eyelet for grounding cable 1

11 2230 0035 00 Angle 90°, 1 1/4" IG, brass 1

12 2230 0041 00 C-fixed coupling 1 1/4" AG 1

13 2210 0005 00 Float holder 1

14 2230 0125 00 Pipe clamp Size 12/15 1

15 2230 0053 00 Screw M6 x 12 2

16 2230 0023 00 Body disk 20x8.5x1.25 1

17 2230 0054 00 Nut M 8, A 2 2

Page 16: Operating Instructions - VETTER Permanent Aspirator

Page 16/20

Vetter Permanent Aspirator

8.5 Switch panel

2

1

345

6

78 9

1

9 97

10 1011

1213

14

15

16

17

18

Article No. / Pos.: Description Qty.

2230025500 Switch panel, consisting of: 1

1 Treble housing, upper and lower part 1

2 Screwed cable gland 1

3 Counter nut 1

4 Lug for grounding cable 1

5 Flat sealing ring 1

6 Connection 2

7 Nut BET 2

8 Line distributer quadruple 1

9 Connecting flange 3

10 Shutter 2

11 Break contact 1

12 Label electrical switch „MPS, PS“ ON/OFF (Illustration different) 1

13 Rotary switch (Illustration different) 2

14 Emergency stop-button 1

15 Label electrical switch „MPS,PS“ Aspirator/Pump (Illustration different) 1

16 Protective Plug, 2 pole, pressure waterproof, DIN 49443 1

17 Wire m 10

18 Cellular rubber gasket 1

Page 17: Operating Instructions - VETTER Permanent Aspirator

Page 17/20

8.6 Suction hose

1

2

Pos.: Article No. Description

1 2230023000 Suction hose, 6 m, oil resistant, including curved connecting pipe

2 2230022800 Adapter Suction hose Aspirators incl. Coupling Storz 38

8.7 Suction pipe, stainless steel (2 parts)

Article No. Description

2230024500 Suction pipe, stainless steel (2 parts)

8.8 Narrow space nozzle

Article No. Description

2230024600 Narrow space nozzle

8.9 Ground nozzle 370 mm

Article No. Description

2230024700 Ground nozzle 370 mm

Page 18: Operating Instructions - VETTER Permanent Aspirator

Page 18/20

Vetter Permanent Aspirator

8.10 Trolley for Permanent Aspirator, GF-Polyester

2

3 1

4

5

6

Pos.: Article No. Description

1 2230 0012 01 Trolley for OWA/PA, GRP, bare

2 2230 0020 00 Guiding roller

3 1700 0167 00 Screw M 8 x 16, hexagon, galv.

4 1700 0168 00 Nut M 8 A2

5 2230 0022 00 Toothed washer M 8, galv.

6 2230 0023 00 Washer 20x 8.5, A 2

9. Resistance Guide

Detailed information about the chemical resistance please find in the appendix!

Page 19: Operating Instructions - VETTER Permanent Aspirator

Page 19/20

EC Conformity Declaration (available on request)

in terms of the EC Directive 2006/42/EC

We

Vetter GmbH A Unit of IDEX Corporation Blatzheimer Str. 10 - 12 53909 Zülpich

hereby declare that the aspirators

OWS for aspirating and temporary storage of liquidsPS for aspirating and pumping of liquids

Serial no.: ______________ Design: ______________

(see ratings plate, to be completed by customer)

complies with the following pertinent regulations in its standard design:

Directive 2006/42/EC

National standards, harmonised standards, technical specifications employed:

EN 60335-1 (2003) = DIN VDE 0700-1 (2004)DIN EN 60335-2-69 (2009)

Authorised representative for the compilation of technical documents:

Vetter GmbH A Unit of IDEX Corporation Blatzheimer Str. 10 - 12 53909 Zülpich

This EC Conformity Declaration was issued:

Zülpich, 22.06.2016

(Place, Date, Signature)

Page 20: Operating Instructions - VETTER Permanent Aspirator

Page 1/2

Chemical resistance list Suction hose

Vetter GmbHA Unit of IDEX Corporation

Blatzheimer Str. 10 - 12D-53909 ZülpichGermany

Tel.: +49 (0) 22 52 / 30 08-0Fax: +49 (0) 22 52 / 30 08-590

Mail: [email protected]

www.vetter.de

Medium PP

Acetic acid, 1% +

Acetophenone u

Acetyl chloride u

Acid sodium carbonate +

Ammonium hydroxide, 10 % +/-

Ammonium nitrate saturated solution +

Ammonium phosphate +

Aniline u

Anti-free additive +

Benzaldehyde u

Benzyl chloride u

Beverages, also alcoholic +

Butyl acetate u

Calcium acetate u

Calcium hydroxide u

Carbon tetrachloride u

Chromium acid u

Cleaning agent, high conc., up to 45 °C -

Cleaning agent, normal conc. up to 25 °C (soap solution, P-3 alkali, dishwasher agents, etc.) +

Cyclohexane, cyclohexanone, cyclohexanol u

Detergent for textiles, normal leaching concentrations +

Dichlorethane, dichloromethane u

Diesel fuel +

Diethylenglycol, 50% +/-

Dioxane u

Dishwasher agent, normal conc. +

Ethanol +

Ethyl acetate u

Ethylene glycol +

Formaldehyde, 20% +/-

Formic acid, 30 % u

Glycerine +

Glycol +

Greases and oils, acid-free from natural and mineral oil basis +

Heating oil, EL +

Heptane u

Hydrochloric acid, 0.5% - 1% u

The information is based on laboratory examinations, empirical values and is influenced by variable factors such as the temperature, intensity and the contact time.This resistance list was compiled based on the above aspects. The information corresponds to today‘s state of our knowledge and should be taken as typical va-lues.

Chemical resistance+ Resistant, no corrosion is expected

+/- Slight effect of the medium is to be expected, but still commercially tenable

- Cannot be used permanently, occasional use pos-sible

u Unstable, use is not recommended

Experiences available on the following media (each at room temperature):

Page 21: Operating Instructions - VETTER Permanent Aspirator

Page 2/2

Chemical resistance list Suction hose

Vetter GmbHA Unit of IDEX Corporation

Blatzheimer Str. 10 - 12D-53909 ZülpichGermany

Tel.: +49 (0) 22 52 / 30 08-0Fax: +49 (0) 22 52 / 30 08-590

Mail: [email protected]

www.vetter.de

Isopropanol +/-

Lactic acid uLiquid fertiliser +

Methyl ethyl ketone u

Methylene chloride u

Nitric acid, 3% u

Oil and greases, acid-free from natural and mineral oil basis +

Petroleum u

Phenol u

Phosphoric acid, 10% u

Polyglycols +

Potassium carbonate, 30% potash +

Potassium chloride +

Potassium hydroxide, 20% +/-

Propylene glycol -

Pyridine u

Silage effluents u

Sodium borate +

Sodium hydrogenphosphate +

Sodium hydroxide, 10% +

Sodium hydroxide, 20% -

Sodium nitrate +

Sodium perborate hydrate +

Sodium sulphate +

Sulphur dioxide (flue gas scrubbing) u

Sulphuric acid, 3% u

Synthetic based oils u

"Fuel economy engine oil for vehicles" (chlorinated phosphate ester, etc.) -

Tetrachlorohydrocarbons u

Tetrahydrofuran u

Toluene u

Trichloroethene u

Tri-sodium phosphate +

Uric acid +

Water:

- Boiler feedwater +

- Carbonated -

- Condensate +

- Cooling water +

- Distilled -

- Drainage water +

- Fire-extinguishing water +

- Heater water +

- Lime water -

- Ocean water -

- Sea water (North Sea, Baltic Sea) +/-

- Swimming pool water, chlorous, up to 2 mg / l +/-

Page 22: Operating Instructions - VETTER Permanent Aspirator

Page 1/13

Chemical resistance list Products made of fibreglass-reinforced polyester

Vetter GmbHA Unit of IDEX Corporation

Blatzheimer Str. 10 - 12D-53909 ZülpichGermany

Tel.: +49 (0) 22 52 / 30 08-0Fax: +49 (0) 22 52 / 30 08-590

Mail: [email protected]

www.vetter.de

Medium GRP

Aceit acid, conc. B

Acetaldehyde B

Acetic acid 10 % A

Acetic acid 25 % B

Acetic acid 75 % B

Acetic acid anhydride

Acetic acid ethyl ester C

Acetic acid, vapours B

Acetone D

Acetylene B

Adiponitrile

Aero Hydraulic HFA A

Aero Mobile HFA A

Aero Safe 2300 W A

Aero Shell-Fluid No. 7 A

Air Hydraulic A

Aircraft AA

Alcohol B

Alum A

Aluminium chloride A

Aluminium fluoride A

Aluminium sulphate A

Alvania EP Grease 2 A

Ammonia B

Ammonia, aqueous B

Ammonia, gaseous, cold B

Ammonia, gaseous, hot C

Ammonium carbonate A

Ammonium chloride A

Ammonium hydroxide A

Ammonium nitrate A

Ammonium sulphate A

Amocool Soluble 3%

Amyl acetate C

Amyl alcohol B

Andol, 4,5 HL 36

The information is based on laboratory examinations,empirical values and is influenced by variable factorssuch as the temperature, intensity and the contacttime. Exposure time 7 daysThis resistance list was compiled based on the aboveaspects. The information corresponds to today‘s stateof our knowledge and should be taken as typical va-lues.

Chemical resistanceA High resistance

B Resistant

C Limited resistance

D Unstable or highly emollient

Not tested

Experiences are available on the following media (each at room temperature unless stated otherwise):

Page 23: Operating Instructions - VETTER Permanent Aspirator

Page 2/13

Chemical resistance list Products made of fibreglass-reinforced polyester

Vetter GmbHA Unit of IDEX Corporation

Blatzheimer Str. 10 - 12D-53909 ZülpichGermany

Tel.: +49 (0) 22 52 / 30 08-0Fax: +49 (0) 22 52 / 30 08-590

Mail: [email protected]

www.vetter.de

Aniline C

Aniline dyes A

APL 731 - Shell A

APL 742 - Shell A

Apresslube 79 A

Aqua regia B

Aral - BV - CMS A

Aral - GFY/4017 A

Aral - HDK A

Aral - HDY A

Aral - HFX A

Aral - HFY A

Aral - HFY/3077 A

Aramco crude oil A

Arctis

Aroclor

Arsenic

ASTM fuel no. 1 A

ASTM fuel no. 2 A

ASTM fuel no. 3 A

ASTM oil no. 1 A

ASTM oil no. 2 A

ASTM oil no. 3 A

ATE-blue brake fluid B

ATF 200 Mobil A

Automatic transm. Fluid A

Bacharquero crude oil A

Barium chloride A

Barium salts A

Battery acid A

BC 48

Becroson KSM

Beer A

Benzaldehyde B

Benzol C

Benzyl alcohol B

Benzyl chloride C

Benzyne, ligroin, naphtha B

Bichloride of mercury A

Bitumen B

Blast gas

BM 68 concentrate

Borax A

Boric acid

BP-Öl HP 0 A

BP-ÖL Hy S 35 A

Page 24: Operating Instructions - VETTER Permanent Aspirator

Page 3/13

Chemical resistance list Products made of fibreglass-reinforced polyester

Vetter GmbHA Unit of IDEX Corporation

Blatzheimer Str. 10 - 12D-53909 ZülpichGermany

Tel.: +49 (0) 22 52 / 30 08-0Fax: +49 (0) 22 52 / 30 08-590

Mail: [email protected]

www.vetter.de

Medium GRP

BP-Öl HY S 45 A

Brega crude oil B

Bromine C

Bromobenzene C

Butane, dry B

Butane, moist B

Butanol A

Butyl acetate C

Butyl alcohol A

Butyl stearate A

Calcium chloride A

Calcium hydroxide A

Calcium hypochlorite B

Calcium salts A

Caltex low temp. oil

Calypso fat M 2

Calypso fat WJA

Carbolic acid

Carbolineum

Carbon dioxide, dry A

Carbon dioxide, wet A

Carbon disulphide C

Carbon monoxide, hot

Carbonic acid A

Castor oil D

Castrol-Rustilo 209

Caustic lye 10% B

Caustic lye 25 % B

Caustic lye 50 % B

Caustic potash B

Caustic soda B

Cherron spindle oil SX

Chlorinated solvent C

Chlorine baths C

Chlorine, dry B

Chlorine, wet B

Chloroacetic acid C

The information is based on laboratory examinations,empirical values and is influenced by variable factorssuch as the temperature, intensity and the contacttime. Exposure time 7 daysThis resistance list was compiled based on the aboveaspects. The information corresponds to today‘s stateof our knowledge and should be taken as typical va-lues.

Chemical resistanceA High resistance

B Resistant

C Limited resistance

D Unstable or highly emollient

Not tested

Experiences are available on the following media (each at room temperature unless stated otherwise):

Page 25: Operating Instructions - VETTER Permanent Aspirator

Page 4/13

Chemical resistance list Products made of fibreglass-reinforced polyester

Vetter GmbHA Unit of IDEX Corporation

Blatzheimer Str. 10 - 12D-53909 ZülpichGermany

Tel.: +49 (0) 22 52 / 30 08-0Fax: +49 (0) 22 52 / 30 08-590

Mail: [email protected]

www.vetter.de

Chlorobenzene C

Chloroform C

Chloroprene C

Chlorosulphuric acid B

Chromium acid D

Cirkan 21

Citric acid A

Citronella oil

Clavus 17

Clavus 27

Clophen B

Coal tar oil

Coconut oil A

Coke-oven gas

Copper chloride A

Copper salts A

Corn oil A

Cottonseed oil

Creosote

Creosote from coal

Creosote from wood

Cupric sulphate A

Cyclohexane B

Cyclohexanol B

Cyclohexanon B

D.T.E. 23 Mobil

D.T.E. Heavy

DASCO IFR-2 hydr. fluid

Delial suntan lotion A

Dextro-tartaric acid A

Diala

Dibenzylether

Dibutyl phthalate A

Dichlorbutylene

Dichlorobenzene C

Dicyclohexylamine

Diethanolamine B

Diethyl sulfate B

Diethylamine B

Diethylsebacat B

Dimethyl ether C

Dimethyl formamide B

Dimethylaniline B

Dioctyl phthalate A

Dioxolane

Dipentene

Diphenyl ether

Page 26: Operating Instructions - VETTER Permanent Aspirator

Page 5/13

Chemical resistance list Products made of fibreglass-reinforced polyester

Vetter GmbHA Unit of IDEX Corporation

Blatzheimer Str. 10 - 12D-53909 ZülpichGermany

Tel.: +49 (0) 22 52 / 30 08-0Fax: +49 (0) 22 52 / 30 08-590

Mail: [email protected]

www.vetter.de

Medium GRP

Dioctyl phthalate A

Dioxolane

Dipentene

Diphenyl ether

Diphenylether

Diphyl (mixture of biphenyl and diphenyl ether)

Distilled spirits A

Doaxane C

Donaxine I 6

Dusarite water

Dusek I 150

E 100 - Hydraulic medium

Ecubsol-Widroflamm 5.5

ED 60/70-Mobil oil

ED 66/11-Mobil oil

Elmodur B

Energol CFS 100 A

Energol HDSAE - 20W/20 A

Energol HL 100 A

Energol HL 65 A

Energol HLP 100 A

Energol HP 20 A

Energol NRA - 31 A

Energol SHF 0202-7 A

Energol TH 100-HB A

Ensis (motor oil 30) A

Essential oils C

Esstic 42

Esstic 55

Estic 45

Estor HD 10

Ethane B

Ethanolamine B

Ether C

Ethyl acetate C

Ethyl alcohol B

Ethyl alcohol, denat. B

The information is based on laboratory examinations,empirical values and is influenced by variable factorssuch as the temperature, intensity and the contacttime. Exposure time 7 daysThis resistance list was compiled based on the aboveaspects. The information corresponds to today‘s stateof our knowledge and should be taken as typical va-lues.

Chemical resistanceA High resistance

B Resistant

C Limited resistance

D Unstable or highly emollient

Not tested

Experiences are available on the following media (each at room temperature unless stated otherwise):

Page 27: Operating Instructions - VETTER Permanent Aspirator

Page 6/13

Chemical resistance list Products made of fibreglass-reinforced polyester

Vetter GmbHA Unit of IDEX Corporation

Blatzheimer Str. 10 - 12D-53909 ZülpichGermany

Tel.: +49 (0) 22 52 / 30 08-0Fax: +49 (0) 22 52 / 30 08-590

Mail: [email protected]

www.vetter.de

Ethyl cellulose A

Ethyl silicate A

Ethylbenzene C

Ethylchloride C

Ethylene B

Ethylene chloride C

Ethylene chlorohydrin C

Ethylene dibromide C

Ethylene dichloride D

Ethylene glycol A

Ethylene mercaptan

Ethylene oxalate A

Ethylenediamine B

F 4 /Th. Goldschmidt)

F 4 hc (Th. Goldschmidt)

Fatty acids A

FC - 75 (Flourchamical)

FC - 77 (Flourchemical)

Flowrex E

Flue gas

Fluid 200 y Mobil transformer

Fluid 4 Aero Shell

Fluorobenzene C

Flurfural C

Formaldehyde B

Formamide: pure

Formic acid B

FR 1 (Mosanto)

FR Fluid B

Frigen /Freon) no. 11 B

Frigen /Freon) no. 113 A

Frigen /Freon) no. 12 B

Frigen /Freon) no. 14 B

Frigen /Freon) no. 21 B

Frigen /Freon) no. 22 B

Frigus

Furan, furfurane C

Fyrquel 220

Fyrquel 220 (80 degrees)

Gasoline 504

Gasoline DK 305

Gasoline FKL

Gasoline FKM

Gasoline TU 504

Gasoline Vitam DH

Gelantine A

Generator gas A

Page 28: Operating Instructions - VETTER Permanent Aspirator

Page 7/13

Chemical resistance list Products made of fibreglass-reinforced polyester

Vetter GmbHA Unit of IDEX Corporation

Blatzheimer Str. 10 - 12D-53909 ZülpichGermany

Tel.: +49 (0) 22 52 / 30 08-0Fax: +49 (0) 22 52 / 30 08-590

Mail: [email protected]

www.vetter.de

Medium GRP

Genrex 24

Glacial acetic acid (conc.), pure C

Glucose A

Glue A

Glycerine A

Glycol A

Hassi Masurad

Heating oil A

Hexane B

Hydran 21

Hydran 25

Hydraulic HBN PC

Hydraulic L

Hydraulic M 4174

Hydraulic MW 30

Hydraulic STDL/C

Hydraulubric X

Hydrazinobenzene

Hydrazol 45

Hydrit B 111

Hydro 5025

Hydrobromic acid, aqueous C

Hydrochloric acid <65 degrees C. C

Hydrochloric acid >65 degrees C. C

Hydrochloric acid, concentrated C

Hydrofluoric acid B

Hydrogen cyanide B

Hydrogen fluoride B

Hydrogen fluoride, cold < 65% A

Hydrogen fluoride, cold > 65% A

Hydrogen fluoride, hot < 65% C

Hydrogen fluoride, hot > 65% C

Hydrogen gas, cold A

Hydrogen gas, hot B

Hydrogen sulfide, cold A

Hydrogen sulfide, dry, cold

The information is based on laboratory examinations,empirical values and is influenced by variable factorssuch as the temperature, intensity and the contacttime. Exposure time 7 daysThis resistance list was compiled based on the aboveaspects. The information corresponds to today‘s stateof our knowledge and should be taken as typical va-lues.

Chemical resistanceA High resistance

B Resistant

C Limited resistance

D Unstable or highly emollient

Not tested

Experiences are available on the following media (each at room temperature unless stated otherwise):

Page 29: Operating Instructions - VETTER Permanent Aspirator

Page 8/13

Chemical resistance list Products made of fibreglass-reinforced polyester

Vetter GmbHA Unit of IDEX Corporation

Blatzheimer Str. 10 - 12D-53909 ZülpichGermany

Tel.: +49 (0) 22 52 / 30 08-0Fax: +49 (0) 22 52 / 30 08-590

Mail: [email protected]

www.vetter.de

Hydrogen sulfide, dry, hot

Hydrogen sulfide, hot C

Illuminating gas A

Inavol 3045

Iron chloride A

Iron sulphate A

Isobutyl alcohol B

Isopropyl chloride

Isopropyl ether B

Jatol-special hydraulic 54,8/50 A

Jatol-special hydraulic ES 7,7/50 A

Jatol-special hydraulic L2,7/50 A

Jatol-special hydraulic M3,5/50 A

kd oil

Kenlube B-521

Kerosenes

KH 60

Klosterfrau spirit of melissa

Lactic acid, cold A

Lactic acid, hot B

Lard A

Lead acetate A

Lead nitrite A

Linseed oil A

Lubricating oil

Lubricor hydraul. B 14 A

Macoma 68

Magnesium chloride A

Magnesium hydrate A

Magnesium salts A

Magnesium sulphate A

Maleic acid A

Maleic acid anhydride A

Malic acid A

Mamellin

Mercury A

Meropa Lubricant 2

Methacrylic acid methyl ester C

Methanol C

Methyl alcohol A

Methyl ethyl ketone C

Methyl salicylate

Methylene chloride D

Methylglycol acetate D

Page 30: Operating Instructions - VETTER Permanent Aspirator

Page 9/13

Chemical resistance list Products made of fibreglass-reinforced polyester

Vetter GmbHA Unit of IDEX Corporation

Blatzheimer Str. 10 - 12D-53909 ZülpichGermany

Tel.: +49 (0) 22 52 / 30 08-0Fax: +49 (0) 22 52 / 30 08-590

Mail: [email protected]

www.vetter.de

Medium GRP

Methylpyrrolidone D

Milk A

Mineral oil A

Mineral oil A

Mipolan mass 5319

Mirbane oil

Molub Alloy 601

Molub Alloy 602

Molub Alloy 603

Molykote A

(Mono)chlorobenzene C

Monoethanolamine

Motor (engine) oils A

Motor oil 20W/20 A

Motor oil 30 A

Motor oil W 10 A

Mustard A

Nafic H 402

Nafic H 404

Naphtha

Naphthalene

Naptolen ZD

Natural gas A

Nickel Chloride A

Nickel salts A

Nickel sulphate A

Nitric acid, diluted B

Nitrobenzene (mirbane oil) C

Nuto 022 H

Nuto H 36

Nuto H 44

Nyvac no. 20 A

Ocean water, 5% A

O-chloronaphthalene C

Oel-Sythesco CH 33

Oleic acid A

Olesimon 803

The information is based on laboratory examinations,empirical values and is influenced by variable factorssuch as the temperature, intensity and the contacttime. Exposure time 7 daysThis resistance list was compiled based on the aboveaspects. The information corresponds to today‘s stateof our knowledge and should be taken as typical va-lues.

Chemical resistanceA High resistance

B Resistant

C Limited resistance

D Unstable or highly emollient

Not tested

Experiences are available on the following media (each at room temperature unless stated otherwise):

Page 31: Operating Instructions - VETTER Permanent Aspirator

Page 10/13

Chemical resistance list Products made of fibreglass-reinforced polyester

Vetter GmbHA Unit of IDEX Corporation

Blatzheimer Str. 10 - 12D-53909 ZülpichGermany

Tel.: +49 (0) 22 52 / 30 08-0Fax: +49 (0) 22 52 / 30 08-590

Mail: [email protected]

www.vetter.de

Olex SHF 0300

Olex SHF 0303

Olex SHF 0304

Olex SHF 0305

Olex SHF 0309

Olive oil A

Oxalic acid A

Oxo-C 4 -degassed

Oxygen, cold

Ozone B

P 1962 (corrosion protection)

P 2614 concentrate

PAGB 5

Palmitic acid B

Panaclor 85 A

Paraffin A

Paraffin oil

Pena Pura HD 30

Pena Pura HD Super SAE 10

Pena Pura HD Super SAE 30

Pena Pura HDSAE 10 W

Pen-o-Led EP 2

Pentosin-Super Fluid

Perchloroethylene 50 degrees C. C

Perfekthion S

Petroleum A

Petroleum ether C

Phenol C

Phenylbenzene

Phosphoric acid (conc.)

Phosphoric acid, cold < 45 % A

Phosphoric acid, cold > 45 % A

Phosphoric acid, hot B

Phosphorus trichloride C

Phthalic anhydride A

Picric acid, aqueous

Picric acid, melted

Piperidine

Potassium bisulfate A

Potassium chloride A

Potassium cyanide A

Potassium hydroxide C

Potassium sulphate A

Page 32: Operating Instructions - VETTER Permanent Aspirator

Page 11/13

Chemical resistance list Products made of fibreglass-reinforced polyester

Vetter GmbHA Unit of IDEX Corporation

Blatzheimer Str. 10 - 12D-53909 ZülpichGermany

Tel.: +49 (0) 22 52 / 30 08-0Fax: +49 (0) 22 52 / 30 08-590

Mail: [email protected]

www.vetter.de

Medium GRP

Progil oil

Propane

Propanol 50 degrees C B

Propyl alcohol A

Prosol ZD

Pydraul 150

Pydraul 280

Pydraul 312

Pydraul 625

Pydraul A 200

Pydraul AC

Pydraul E

Pydraul F 9

Pyrogard 43

Pyrrole

Quaker 8211 M oil

Regal oil B

Renolin 2

Renolin B 15

Renolin MR 20

Renolin NF 2

Renolin NF 4

Salicylic acid A

Shell Emulion M 2

Shell IYO

Shell JPH

Shell JPL

Silver nitrate(V) A

Skydrol 500 B (60 degrees C.)

Soap solutions B

Sodium carbonate A

Sodium carbonate A

Sodium chloride A

Sodium cyanide A

Sodium dichromate B

Sodium hydroxide B

Sodium hypochlorite A

The information is based on laboratory examinations,empirical values and is influenced by variable factorssuch as the temperature, intensity and the contacttime. Exposure time 7 daysThis resistance list was compiled based on the aboveaspects. The information corresponds to today‘s stateof our knowledge and should be taken as typical va-lues.

Chemical resistanceA High resistance

B Resistant

C Limited resistance

D Unstable or highly emollient

Not tested

Experiences are available on the following media (each at room temperature unless stated otherwise):

Page 33: Operating Instructions - VETTER Permanent Aspirator

Page 12/13

Chemical resistance list Products made of fibreglass-reinforced polyester

Vetter GmbHA Unit of IDEX Corporation

Blatzheimer Str. 10 - 12D-53909 ZülpichGermany

Tel.: +49 (0) 22 52 / 30 08-0Fax: +49 (0) 22 52 / 30 08-590

Mail: [email protected]

www.vetter.de

Sodium nitrate A

Sodium phosphate A

Sodium silicate A

Sodium sulfide A

Sodium sulphate A

Sodium thiosulfate A

Somentor F

Somentor N 35

Somentor W 20

Somentor W 26

Son low 3

Soy bean oil A

Spindle oil A

Spinesso 34

Spruce turpentine A

Stearic acid A

Styrol C

Sugar beet juice A

Sulfate of zinc A

Sulfurous acid C

Sulphur chloride

Sulphur dioxide B

Sulphur trioxide B

Sulphuric acid 10% A

Sulphuric acid 25% A

Sulphuric acid 50% A

Sulphuric acid 75% C

Sulphuric acid 96% D

Sulphuric acid, concentrated D

Sulphuric acid, smoking D

Tannic acid A

Tar

Tartaric acid A

Tetrachlorohydrocarbons

Tetracloroethylene C

Tetrahydrofuran C

Thioglycolic acid

Tin chloride A

Toluene 20 degrees C. C

Transmission oil

Tributyl phosphate

Trichlorobenzene C

Triethanolamine

Page 34: Operating Instructions - VETTER Permanent Aspirator

Page 13/13

Chemical resistance list Products made of fibreglass-reinforced polyester

Vetter GmbHA Unit of IDEX Corporation

Blatzheimer Str. 10 - 12D-53909 ZülpichGermany

Tel.: +49 (0) 22 52 / 30 08-0Fax: +49 (0) 22 52 / 30 08-590

Mail: [email protected]

www.vetter.de

Medium GRP

Triphenylmethane 21

Turpentine B

Turpentine oil B

Ucon-Hydrolube z 75 CP

Univis J 43 (Esso)

Univol 42 (Esso)

Ursa oil P 20

Vacra-Heary oil

Vacuoline BB

Vegetable oil A

Venegar B

Waste-water A

Water (ocean water) A

Water peroxide A

Water up to 100 degrees C. C

Water up to 80 degrees C. C

Water, dist. 50 degrees C. B

Water; cold A

Wood oil B

Wool grease

Wüf 265

Wyrol H-40

Xylene B

Zinc salts A

The information is based on laboratory examinations,empirical values and is influenced by variable factorssuch as the temperature, intensity and the contacttime. Exposure time 7 daysThis resistance list was compiled based on the aboveaspects. The information corresponds to today‘s stateof our knowledge and should be taken as typical va-lues.

Chemical resistanceA High resistance

B Resistant

C Limited resistance

D Unstable or highly emollient

Not tested

Experiences are available on the following media (each at room temperature unless stated otherwise):

Page 35: Operating Instructions - VETTER Permanent Aspirator

www.vetter.de

Vetter GmbHA Unit of IDEX Corporation

Blatzheimer Str. 10 - 12D-53909 ZülpichGermany

Sales

Tel.: +49 (0) 22 52 / 30 08-0Fax: +49 (0) 22 52 / 30 08-590Mail: [email protected]

We are the company who can help you, find a solution to your problem!Place your trust in emergency pneumatics!

Article No. 9987011205 | © Vetter GmbH I 06/16 I Changes and errors excepted. | Made in Germany