Top Banner
ACM-MP 513 An ISO 9001:2208 | ISO 14001:2008 | ISO 13485 WHO:GMP Products | GLP Compliant Products
6

online-pH-analyzer-pending

Mar 11, 2016

Download

Documents

ACM-MP 513 An ISO 9001:2208 | ISO 14001:2008 | ISO 13485 WHO:GMP Products | GLP Compliant Products
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: online-pH-analyzer-pending

ACM-MP 513

An ISO 9001:2208 | ISO 14001:2008 | ISO 13485WHO:GMP Products | GLP Compliant Products

Page 2: online-pH-analyzer-pending

Acm- HK 338-Scan Series on line conductivity analyzer

and controllers are Industrial grade On line

conductivity meters and controllers waste water

treatment and other research and industrial

application. These sturdy online conductivity meters

are Wall mounted/ unit with the advantage of being

Panel Mountable and is ideal for such applications as

conductivity control and monitoring in water supply

lines for industrial and process control applications. In

the consideration of safety issues and other constraints

- the use of panel mounted instrumentation in such

industries as Metal Finishing, Chemical process,

Pharmaceutical production, Drug research,

Fermentation and Sewerage treatment is often

mandatory.

Water Treatment :

pH Measurement of Wetlands, Sewage Treatment, pH

in flocculation tanks, Water Purification, Water

Treatment, pH measurements on water filters Use for

batch control, on-line control of incoming process

water, effluent system treatment water and waste water

treatment.

General :Useful for any batch or on-line type application that

requires accurate pH or ORP control.

Industrial : pH control in fume cupboards, Metal Finishing,

Chemical process, Pharmaceutical production, Drug

research, Fermentation and waste control industries

Regulatory : Hook to recorder to document data for regulatory

compliance.

ACMAS TECHNOCRACY PVT. LTD.www.acmasindia.com | www.scientificlaboratoryequipments.com | www.measuring-meters.com

Conductivity MeterController & Analyzer

Page 3: online-pH-analyzer-pending

• Advanced embedded MCU technology.

• SMT and integrative design to enhance the

analyzer's performance and dependability.

• Display language can be set between Chinese and

English.

• You can neglect the influence to the measuring

result that aroused by the length of the conductivity

cell cable as the analyzer has the special 4-

electrode measuring technology.

• You can see the conductivity changing trend

directly according to the history curve.

• All the operation and programming are controlled

by 8 membrane keys.

• The program function is protected by the protective

passwords which protect the user's setting.

• It can connect to the other device directly with the

communicating serial port.

• Two isolated current output and alarm signal.

• The transmitter case is made of ABS material and

the interior shield layer that make the transmitter

firm, smart, antit-static and easy installation.

• Enquire a large part of operation conveniently in

the log menu.

• The membrane key has a longer using life.

• Multi parameters display together that is easy to

understand.

• The screen contrast adjusting is easy and simply.

• The compensation temperature can be measured

automatically or input manually.

• The intelligent measuring and "automatic judge

stability" function to make your work easily.

ACMAS TECHNOCRACY PVT. LTD.www.acmasindia.com | www.scientificlaboratoryequipments.com | www.measuring-meters.com

Page 4: online-pH-analyzer-pending

ACMAS TECHNOCRACY PVT. LTD.www.acmasindia.com | www.scientificlaboratoryequipments.com | www.measuring-meters.com

Conductivity MeterController & Analyzer

Page 5: online-pH-analyzer-pending

Technical Specifications

Conductivity range : (0.000-2.000),(0.00-20.00),(0.0?200.0),

(0-2000)- S/cm(0.000-2.000),

(0.00-20.00)mS/cm

(alternated automatically according

to the cell constant)

Temperature measuring range : (0.0?99.9)?

ATC range : (0.1?60.0)?

Resolution

Conductivity : 0.001uS/cm

Temperature : 0.1?

Precision:

Conductivity : ±1%F.S0Temperature : ±0.50Responding time : At 25 creach the 90% of

the changing in 30s

Current output (0-10), (0-20) or ( 4-20)mA

Max loading resistance : 800

Current output precision : ±1%F.S

Alarm output : Two channel alarm output and the alarm

content can be set by programming.

Communication : CAN bus (optional)0Sample condition : Temperature : (5-50) C

Flux : <_ 6L/H

Solid allow in sample : <_ 5 um (no gel and grease in the sample)0Ambient temperature : (5-45) c

Ambient humidity : <_ 90%RH(no condensation)

Transportation temperature : (-25?55)?

Overall dimension : 158(W)×158(H)×170(D) (mm)

Panel cutout : 140mm×140mm

Power supply : (85~265)VAC, (50~60)Hz

Power consumption : <_ 8VA

Insulation : Power to ground 1500V/1no flying

Gross weight: : 2Kg

ACMAS TECHNOCRACY PVT. LTD.www.acmasindia.com | www.scientificlaboratoryequipments.com | www.measuring-meters.com

Page 6: online-pH-analyzer-pending

SALES OFFICE (INDIA)

312-313, Vardhman Capital Mall, L.S.C. 10, GulabiBagh, Delhi-110052, INDIA

Tel: 0091-11-23646703, 23643054

(M) +91-9313971681| Email: [email protected]

SALES OFFICE (HONG KONG)

Unit D 28 11/f Wing Tat Comm, Bldg 97, Bonham Strand East, Sheung Wan, HONG KONG (PRC).

Tel: 0086-13929598046 | 0086-18922303099

Email: [email protected]

SHOWROOM

141, Rai Industrial Estate, Rai, Sonepat, Haryana-131029, INDIA

Tel: 0091-0-9312219738 (M) +91-9717741167

Email: [email protected]

SALES OFFICE (RUSSIA)

Inmed Trade Street, Ozerkovsky Embankment, Unit No 50 Straine-1, Off-502, Moscow, RUSSIA

Tel: 0049-79592345 | Email: [email protected]

www.measuring-meters.com | www.acmasindia.com | www.scientificlaboratoryequipments.com

TECHNOCRACY PVT. LTD.