Top Banner
Oncology safety products and closed system solutions Alaris ® products
9

Oncology safety products and closed system solutions · to the SmartSite® needle free port. Single drug therapy The SmartSite® needle-free add on bag access device allows closed

Jul 22, 2020

Download

Documents

dariahiddleston
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: Oncology safety products and closed system solutions · to the SmartSite® needle free port. Single drug therapy The SmartSite® needle-free add on bag access device allows closed

Oncology safety products and closed system solutions

Alaris® products

Page 2: Oncology safety products and closed system solutions · to the SmartSite® needle free port. Single drug therapy The SmartSite® needle-free add on bag access device allows closed

The risks of oncology from all sidesEvery day, thousands of pharmacists, nurses, physicians and other

caregivers may encounter a serious threat to their own physical and

reproductive health, often without even realizing it.

While the hazardous nature of chemotherapy, antivirals, antibiotics,

hormones and other drugs is well established, it is estimated that

millions of healthcare workers continue to be exposed to these

substances each year.1

Traces of hazardous drugs have been found on floors and counters in

hospital pharmacies, and on chairs and tabletops at the patient bedside.2

More ominously, multiple studies have detected hazardous drugs in the

urine of workers who handled them and also in the urine of workers

who didn’t.3

“Warning: Working with or near hazardous drugs in health care settings may cause skin rashes, infertility, miscarriage, birth defects and possible leukaemia and other cancers.“ 1

Key FactsHarrison (2001) reported that six different drugs (cyclophosphamide, methrotrexate, ifosfamide,

epirubicin, and cisplatin/carboplatin) were detected in the urine of health care workers by 13 of

20 investigations.

CDC/NIOSH 2004-165: Preventing Occupational

Exposures to Antineoplastic and Other

Hazardous Drugs in Health Care Settings

Traces of hazardous drugs have been found on the floors and counters in hospital pharmacies,

and on the chairs and tabletops at the patient bedside.

Minoia et al: Rapid Commun. Mass Spectrom. 12, 1485-1493 (1998)

1. NIOSH report, 2004.2. Minoia et al. 1998; Connor et al. 1999; Pethran et al. 2003.3. Valanis et al. 1991, 1992; Mahon et al. 1994; Nieweg et al. 1994; Ensslin et al. 1994, 1997; Minoia et al. 1998; Wick et al. 2003.

What you can’t see can hurt you

Page 3: Oncology safety products and closed system solutions · to the SmartSite® needle free port. Single drug therapy The SmartSite® needle-free add on bag access device allows closed

Who is at risk?Exposure risks in the pharmacy

• Reconstituting powdered or lyophilised drugs and further

diluting either the reconstituted powder or concentrated liquid

forms of hazardous drugs using needles

• Expelling air from syringes of hazardous drugs

• Handling contaminated waste

Exposure risks in the patient care area

• Priming or connecting an intravenous administration set

containing a hazardous drug

• Administering a hazardous drug from a syringe

• Handling contaminated waste

When you’re taking care of your cancer patients, you may

be seriously harming yourself at the same time.

When it occursThe above image, photographed under UV light,

illustrates how the standard IV push with needle

and syringe can easily leave unseen dangers

from hazardous drugs to potentially harm the

pharmacist or nurse.

Introducing a closed system solutionCareFusion offers a cost-effective, easy-to-use closed system to help protect healthcare workers anytime they

prepare, transport, administer or dispose of hazardous drugs.

SaferOur Texium® closed male luer and SmartSite® needle-free valve products partner together to form a closed system,

providing leak-free connections and disconnections that help to reduce surface contamination and the risk of

exposure.

SimplerThe luer lock connection of the Texium® closed male luer to a SmartSite® needle-free valve port helps you quickly and

easily achieve a closed system, without adding cumbersome steps to your clinical process.

Complies with NIOSH recommendations Our closed system solution makes it possible for any facility to follow NIOSH recommendations for using closed,

needle-free systems for the safe handling of hazardous drugs.

Your local regulations:

MARCH guidelineHandling and containment from goods received to

clinical areas

Practice Points: preparation areas

• Ensure staff use proprietary containment systems

where possible

Practice Points: clinical areas

• Use proprietary containment systems for

administration where possible

Management and Awareness of Risks of Cytotoxic HandlingHandling and containment from goods received to clinical areasIssue date: 7 June 2007

NIOSH Alert recommendations• When supplemental protection is needed,

use closed system drug transfer devices and

needleless systems inside the ventilated cabinet

• Consider using closed system drug transfer

devices and needleless systems to protect nurses

during drug administration

NIOSH Alert: Preventing Occupational Exposures to Antineoplastic and Other Hazardous Drugs in Health Care SettingsPublication No. 2004–165

Giving you the confidence and security you need to provide care

Exposure risksReconstituting, transporting and administering hazardous

drugs can put health care workers at risk of exposure

to these agents via spillage, surface contamination, and

aerosols. The continued use of needles to draw up and

administer medication also presents a major hazard in

the healthcare environment.

Page 4: Oncology safety products and closed system solutions · to the SmartSite® needle free port. Single drug therapy The SmartSite® needle-free add on bag access device allows closed

In the Pharmacy

Reconstitution Preparation Transportation

How the Texium® closed male luer works

The Texium® closed male luer is based on

a simple luer-lock principle, allowing free

flow of the drug when connected, and

automatically closing when disconnected.

Together, the Texium® closed male luer

and SmartSite® needle-free valve create an

automatically closed system that helps to

eliminate leakage.

The Texium® closed male luer partners

with any SmartSite® needle-free valve

product to create an easy-to-use, closed

needle-free system.

When connected, the fluid path opens. This

path automatically closes upon disconnection.

The patented no-drip-tip technology of the

Texium® closed male luer creates a vacuum

mechanism when closing to ensure a drip-

free, leak-free disconnection.

The SmartSite® vented vial access device

The hydrophobic air inlet filter minimises

aerosols and neutralises vial pressure, thus

reducing the risks of surface contamination.

3040

506

20

0m

l

Multi-drug therapy

Preparation

using Texium®

closed male luer

and SmartSite®

secondary setMale luer lock with

integrated back check

valve.

The back check valve in

the secondary set helps

to reduce back track of

fluid during the infusion

and it is safely connected

to the SmartSite® needle

free port.

Single drug therapy

The SmartSite® needle-free

add on bag access device

allows closed system

additions of drugs to bag

when used with Texium®

closed male luer.

The Texium® closed male luer has an automatic

safety lock that prevents accidental discharges from

the syringe.

On the Ward

Administration Disposal30

40

50

6

20

0ml

Multi-drug therapy using

the “Quattro system”

Allows the connection of up to

four secondary infusions and

delivery of the drug without any

need to disconnect the sets.

The rigid body reduces risk of

kinking ensuring the drug is

promptly delivered to the patient.

The back check valve in the

secondary set reduces the back

track of fluid during the infusion

and it is safely connected to the

SmartSite® needle free port.

Diluent

The Back check

valve integrated into

the air vent reduces

risk of spillage.

The SmartSite®

needle free valve

maintains the safe

closed system

without needles

or caps.

Secondary set

prepared in

the pharmacy

The Alaris® GP volumetric pump

provides a high level of safety.

Utilising the Alaris® safety clamp

helps reduce the risk of free-flow.

The addition of the Guardrails®

Suite of safety software to the

pump can further help to reduce

harmful IV medication errors and

increase compliance with national

safety standards.

Single Drug Therapy

The SmartSite® needle-free

add on bag access device

connected to primary set.

Bolus – Safe and easy closed system

administration of cytotoxic drug with Texium®

closed male luer and theSmartSite® needle-

free valve Y- port on the administration set.

I.V. Push

With the Alaris® SE

volumetric pump the

patients bedside can be

customised via single or

dual channel capabilities.

The AccuSlide® flow

regulator offers the

benefits of set based free

flow protection.

Page 5: Oncology safety products and closed system solutions · to the SmartSite® needle free port. Single drug therapy The SmartSite® needle-free add on bag access device allows closed

SmartSite® add-on bag access device

Key performance specifications

Priming Volume:

Needle-free valve port ~ 0.16 mL

Fluid channel ~ 0.61 mL

Compatibility:

Spike adaptor ISO standard spikes

Material: Latex and DEHP-free

Feature Benefit

SmartSite® needle-free valve bag access port

Direct, needle-free access to IV bags for adding or removing fluids

Universal spike adaptor

Fits any ISO standard spike

Partners with Texium® closed male luer for closed system

access to IV bag.

SmartSite® vented vial access device

Partners with Texium® closed male luer for closed system

access to drug vials.

Key performance specifications

Priming Volume:

Total volume in needle-free valve ~ 0.14 mL

and spike when not activated

Residual Volume:

Quantity of fluid remaining in ~ 0.28 mL

vial after withdrawing the maximum

amount through the access port

Filter: 0.2 micron hydrophobic

Material: Latex, DEHP and ABS

plastic-free

Compatibility: 0.2 micron hydrophobic

Feature Benefit

SmartSite® needle-free

Needle free access to multiple use vials

0.2 micron hydrophobic air venting filter

• Neutralizes vial pressure, minimizing aerosols and surface contamination

• Eases drug extraction

• Bacteria retentive

Dual pathway spike Efficiently transfers fluids for maximum extractable volume

Texium® closed male luer

Partners with SmartSite® needle-free valve to achieve a

closed system.

Key performance specifications

Priming Volume:

Total volume in the male luer ~ 0.12 mL

when not activated

Luer flow rate:

Test per ISO 8536-4 guidelines 5948 mL/hr

Internal diameter: 18 gauge

Material: Latex free, DEHP free

and ABS plastic free

Feature Benefit

No-drip-tip technology

• Leak-free transfer of drugs

• Reduces surface contamination

Passive safety system

• Closes upon disconnection

• Reduces surface contamination

• No inadvertent syringe discharge

Lock-and-go design Fast and easy connection to SmartSite® needle-free valve

Vacuum Technology Reduces risk of exposure to hazardous drug when disconnecting from SmartSite® needle-free valve

Secondary infusion sets Multi-way infusion sets SmartSite® needle free valve

Partners with our range of SmartSite®

needle-free secondary sets to achieve a

closed system during administration of

hazardous drugs.

Puts safety first...• No needle

• No caps

• No metal

• Reduces the risk of

needle-stick injuries

• Straight through non-tortuous

fluid path

• High chemical resistance

(lipids and alcohol)

• Cost-effective, MRI compatible,

latex-free IV administration system

• Partners with Texium® closed male

luer for delivering safe and convenient

IV therapy in a closed system

... without the needle

Feature Benefit

SmartSite®

needle-free valve

• Needle-free connection for the preparation of cytotoxic drugs

• Reduces exposure to hazardous drugs

• Maintains closed system

Back check valves • Integration into spike air vent helps prevent spillage of cytotoxic drugs

• Additional back check valve integrated into the luer lock reduces back track of fluid

Hydrophobic cap Facilitates safe and dry priming

Feature Benefit

SmartSite® needle-free

• Needle-free access for the administration of cytotoxic drugs using secondary sets

• Reduces exposure to hazardous drugs

• Maintains closed system

Rigid body • Reduces risk of kinking

• Easier connection of secondary sets

Back check valves Integration into spike air vent helps prevent spillage of cytotoxic drugs

Hydrophobic cap Facilitates safe and dry priming

DEHP free and PVC free

Avoids patient exposure to DEHP

plasticizer

PE-lined • Prevents leaching of phthalates into fluid pathway, reducing patient exposure to DEHP plasticize

• Prevents drug sorption

Used in conjunction with our range of multi-way

infusion sets and safety accessories, ensures a safe,

closed system.

30

40

5 06

20

0m

l

Page 6: Oncology safety products and closed system solutions · to the SmartSite® needle free port. Single drug therapy The SmartSite® needle-free add on bag access device allows closed

04108362418 Secondary set, vented/unvented

72951NE Secondary set, unvented

72946NE Secondary set, vented/unvented, Light resistant

72947NE Secondary set, unvented, Light resistant

72948NE Secondary set, unvented

MFX2302E Secondary set, vented/unvented

MFX2300E Secondary set light resistant, vented/unvented

MFX2303E Secondary set light resistant, vented/unvented

2300E Bag Spike 2309E Bag Spike,

Back-check valve

10012240 Texium® female cap 10012241 Texium® closed

male luer

10012392

Vented vial

access device

2203E Vial access device 2205E Vial access device

10013365 SmartSite® Add on

bag access device

Set

Leng

th (

cm)

Prim

ing

volu

me

(ml)

Qua

ntit

y

Smar

tSite

® n

eedl

e fr

ee v

alve

s

PVC

fre

e

DEH

P fr

ee

Late

x fr

ee

10012240 Texium® Safety Disposables ~ PushFit Cap 100 • • •

10012241 Priming Volume 0.12 ml ~ Texium® Safety

Disposables 0.12 100 • • •

10012392 Needle-free system ~ Hydrophobic Air Inlet

Filter ~ Vial Access Device Diameter 20 mm 0.14 80 1 • • •

MFX2594E Transfer Spike(s) (Vented) ~ Needle-Free System

~ Dispensing Pin ~ Hydrophobic Air Inlet Filter6.7 0.1 100 1 • • •

2203E Needle-free system ~

Vial Access Device Diameter 13 mm3.5 0.08 100 1 • • •

2205E Needle-free system ~

Vial Access Device Diameter 20 mm 3.5 0.09 100 • • •

10013365 1 Spike (Unvented) ~ Bag Access Device ~

Needle-free system ~ PVC NODOP ~ Spike Port

Adaptor

9.6 0.61 100 1 • •

2300E 1 Spike (Unvented) ~ Bag Access Device ~

Needle-free system0.47 100 1 • • •

2309E 1 Spike (Unvented) ~ Bag Access Device ~

Needle-free system ~ 1 Back-check Valve13.35 0.9 100 1 • •

Texium® closed male luer

Vial Access devices

Bag Access devices

Texi

um

® c

lose

d

mal

e lu

erV

ial

Acc

ess

dev

ices

Bag

A

cces

s d

evic

es

MFX2594E Dispensing pin

Reconstitution

Set

Leng

th (

cm)

Prim

ing

volu

me

(ml)

Bore

(m

m)

Qua

ntit

y

Dro

ps p

er m

l

Inlin

e Fi

lter

(µm

)

Hyd

roph

obic

Prim

ing

Cap

Air

Inle

t V

alve

Mal

e lu

er b

ack-

chec

k va

lve

Smar

tSite

® V

alve

Y P

orts

PVC

fre

e

DEH

P fr

ee

Late

x fr

ee

04108362418 1 Spike (Vented/Unvented) ~ Rotating Male Luer(s) ~ Hydrophobic Air Inlet Filter ~ Needle-Free System

31 2.3 3 100 • 1 • •

72951NE 1 Spike (Unvented) ~ Needle-Free System ~ PVC NODOP ~ 1 Pinch Clamp 35 3 3 100 • 1 1 • •

72946NE 1 Spike (Vented/Unvented) ~ Rotating Male Luer(s) ~ Hydrophobic Air Inlet Filter ~ Needle-Free System~ Light resistant ~ PVC NODOP ~ Hydrophobic cap ~ 1 Pinch Clamp

31 2.3 3 50 • 1 • •

72947NE 1 Spike (Unvented) ~ Needle-free system ~ PVC NODOP ~ Light resistant ~ 1 Pinch Clamp ~ Hydrophobic cap

35 3 3 50 • 1 1 • •

72948NE 1 Spike (Unvented) ~ Needle-Free System~ PVC NODOP ~ 2 Pinch Clamps ~ Hydrophobic cap 50 6 3 50 0.2 • 1 1 • •

MFX2302E 1 Spike (Vented/Unvented) ~ Needle-Free System ~ Vented Filter ~ Hydrophobic Air Inlet Filter ~ Polyurethane ~ 1 Pinch Clamp

55 4.1 3 50 0.2 • • 1 1 • • •

MFX2301E 1 Spike (Vented/Unvented) ~ Needle-Free System ~ Hydrophobic Air Inlet Filter ~ Polyurethane ~ 1 Pinch Clamp

41 2 3 50 • • 1 1 • • •

MFX2300E 1 Spike (Vented/Unvented) ~ Needle-Free System ~ Hydrophobic Air Inlet Filter ~ Low sorbing ~ Polyethylene lined PVC ~ Light resistant ~ 1 Pinch Clamp

41 2 3 50 • • 1 1 • •

MFX2303E 1 Spike (Vented/Unvented) ~ Needle-Free System ~ Flow Controller ~ Hydrophobic Air Inlet Filter ~ Low sorbing ~ Polyethylene lined PVC ~ Light resistant ~ 1 Pinch Clamp

47 2.4 3 50 • • 1 1 • •

MFX2304E Needle-Free System ~ Male luer lock to male luer lock connecting line ~ Polyurethane ~ 1 Pinch Clamp

35 2.1 3 50 • 1 1 • • •

PreparationSecondary sets

Seco

nd

ary

sets

Model Number: 72951NEArtwork Number: 1000AW02971

CO Number Change Description Drawn by7131 Introduction AWC10793 Update spike AWC

Change HistoryIssue Date

12

29/08/0623/06/10

Page 7: Oncology safety products and closed system solutions · to the SmartSite® needle free port. Single drug therapy The SmartSite® needle-free add on bag access device allows closed

Set

Leng

th (

cm)

Prim

ing

volu

me

(ml)

Bore

(m

m)

Qua

ntit

y

Dro

ps p

er m

l

Inlin

e Fi

lter

(µm

)

Drip

Cha

mbe

r fil

ter

(µm

)

Fem

ale

luer

bac

k-ch

eck

valv

es

Back

-che

ck v

alve

Smar

tSite

® V

alve

Y P

orts

PVC

fre

e

DEH

P fr

ee

Late

x fr

ee

MFX72950E 1 Spike (Vented/Unvented) ~ In-Line Drip Chamber ~ Needle-Free System ~ Hydrophobic Priming Cap ~ Rotating Male Luer ~ Hydrophobic Air Inlet Filter ~ Air Inlet Valve ~ AccuSlide

™ Flow Regulator ~ PVC NODOP ~ Polyurethane ~ 3

Pinch Clamps ~ 1 Roller Clamp

265 29 3 35 20 15 5 • •

MFX72952E 1 Spike (Vented/Unvented) ~ In-Line Drip Chamber ~ Needle-Free System ~ Hydrophobic Priming Cap ~ Rotating Male Luer ~ Hydrophobic Air Inlet Filter ~ Air Inlet Valve ~ AccuSlide

® Flow

Regulator ~ Low sorbing ~ PVC NODOP ~ Polyethylene lined PVC ~ Light resistant ~ 3 Pinch Clamps ~ 1 Roller Clamp

265 29 3 35 20 15 5 • •

MFX273-950E 1 Spike (Vented/Unvented) ~ In-Line Drip Chamber ~ Needle-Free System ~ Hydrophobic Priming Cap ~ Rotating Male Luer ~ Hydrophobic Air Inlet Filter ~ Air Inlet Valve ~ In-Line Back-check valve ~ Polyurethane ~ 3 Pinch Clamps ~ 1 Roller Clamp

265 29 3 35 20 15 • 5 •

MFX273-951E 1 Spike (Vented/Unvented) ~ In-Line Drip Chamber ~ Needle-Free System ~ Hydrophobic Priming Cap ~ Rotating Male Luer ~ Hydrophobic Air Inlet Filter ~ Air Inlet Valve ~ In-Line Back-check valve ~ Polyurethane ~ 3 Pinch Clamps ~ 1 Roller Clamp

265 29 3 35 20 15 • 3 •

MFX273-952E 1 Spike (Vented/Unvented) ~ In-Line Drip Chamber ~ Needle-Free System ~ Hydrophobic Priming Cap ~ Rotating Male Luer ~ Hydrophobic Air Inlet Filter ~ Air Inlet Valve ~ In-Line Back-check valve ~ PE/PVC NODOP ~ 3 Pinch Clamps ~ 1 Roller Clamp

265 29 3 35 20 15 • 5 •

MFX273-954E 1 Spike (Vented/Unvented) ~ In-Line Drip Chamber ~ Needle-Free System ~ Hydrophobic Priming Cap ~ Rotating Male Luer ~ Hydrophobic Air Inlet Filter ~ Air Inlet Valve ~ In-Line Back-check valve ~ PE/PVC NODOP ~ 3 Pinch Clamps ~ 1 Roller Clamp

265 29 3 35 20 15 • 3 •

AdministrationMulti-way oncology sets

60033E 1 Spiked Drip Chamber (Vented/Unvented) ~ Needle-Free System ~ Vented Filter ~ 2 SmartSite

® Valve Y Ports ~ Alaris

® Safety Clamp

Hydrophobic Air Inlet Filter ~ Silicone pump segment ~ Low Sorbing ~ Polyethylene lined PVC ~ 1 Pinch Clamp ~ 1 Roller Clamp

265 25 2.7 50 20 0.2 2 • •

60953 1 Spiked Drip Chamber (Vented/Unvented) ~ Alaris® Safety Clamp ~

Hydrophobic Air Inlet Filter ~ Silicone pump segment ~ Low Sorbing ~ Polyethylene lined PVC ~ 1 Pinch Clamp ~ 1 Roller Clamp

260 24 3 80 20 15 • •

72923- 0006

1 Spiked Drip Chamber (Vented/Unvented) ~ Vented Filter ~ Rotating Male Luer ~ Hydrophobic Air Inlet Filter ~ AccuSlide

®

Flow Regulator ~ Silicone pump segment ~ Low Sorbing ~ Polyethylene lined PVC

284 23 2.7 50 20 0.2 •

72923E- 0006

1 Spiked Drip Chamber (Vented/Unvented) ~ Vented Filter ~ Rotating Male Luer ~ Hydrophobic Air Inlet Filter ~ AccuSlide

®

Flow Regulator ~ Silicone pump segment ~ Low Sorbing ~ Polyethylene lined PVC ~ Needle-Free System

300 26 2.7 50 20 0.2 1 •

72953- 0006

1 Spiked Drip Chamber (Vented/Unvented) ~ Rotating Male Luer(s) ~ Hydrophobic Air Inlet Filter ~ AccuSlide

® Flow Regulator ~

Silicone pump segment ~ Low Sorbing ~ Polyethylene lined PVC279 22 2.7 20 20 •

Single-drug oncology sets

Set

Leng

th (

cm)

Prim

ing

volu

me

(ml)

Bore

(m

m)

Qua

ntit

y

Dro

ps p

er m

l

Inlin

e Fi

lter

(µm

)

Drip

Cha

mbe

r fil

ter

(µm

)

Fem

ale

luer

bac

k-ch

eck

valv

es

Back

-che

ck v

alve

Smar

tSite

® V

alve

Y P

orts

PVC

fre

e

DEH

P fr

ee

Late

x fr

ee

04108341419 1 Spike (Vented/Unvented) ~ Hydrophobic Air Inlet Filter ~ PVC NODOP ~ Spike Port Adaptor ~ 1 Pinch Clamp

26 3.2 3 100 4 • •

2305E 1 Spike (Vented/Unvented) ~ transparent ~ Needle-free system ~ Hydrophobic Air Inlet Filter ~ Spike Port Adaptor ~ Air Inlet Valve ~ 1 Pinch Clamp

30 2 3 60 4 • •

MFX2307E 1 Spike (Vented/Unvented) ~ Needle-Free System ~ Hydrophobic Air Inlet Filter ~ Low Sorbing ~ PVC NODOP~ Polyethylene lined PVC ~ Light resistant ~ Spike Port Adaptor ~ Air Inlet Valve ~ 1 Pinch Clamp

30 2 3 60 4 • •

2306E 1 Spike (Vented/Unvented) ~ transparent ~ Needle-free system ~ Hydrophobic Air Inlet Filter ~ Spike Port Adaptor ~ Air Inlet Valve ~ 1 Pinch Clamp

25 2 3 60 2 • •

MFX2308E 1 Spike (Vented/Unvented) ~ Needle-Free System ~ Hydrophobic Air Inlet Filter ~ Low Sorbing ~ PVC NODOP~ Polyethylene lined PVC ~ Light resistant ~ Spike Port Adaptor ~ Air Inlet Valve ~ 1 Pinch Clamp

26 1.7 3 60 2 • •

60950E 1 Spike (Vented/Unvented) ~ In-Line Drip Chamber ~ Needle-Free System ~ Hydrophobic Priming Cap ~ Rotating Male Luer ~ Alaris® Safety Clamp ~ Hydrophobic Air Inlet Filter ~ Pump Segment ~ Air Inlet Valve ~ 2 Pinch Clamps ~ 1 Roller Clamp

260 24 3 50 20 15 5 • •

60951E 1 Spike (Vented/Unvented) ~ In-Line Drip Chamber ~ Needle-Free System ~ Hydrophobic Priming Cap ~ Rotating Male Luer ~ Alaris® Safety Clamp ~ Hydrophobic Air Inlet Filter ~ Pump Segment ~ Air Inlet Valve ~ 2 Pinch Clamps ~ 1 Roller Clamp

260 24 3 50 20 15 3 • •

60952E 1 Spike (Vented/Unvented) ~ In-Line Drip Chamber ~ Needle-Free System ~ Hydrophobic Priming Cap ~ Rotating Male Luer ~ Alaris® Safety Clamp ~ Hydrophobic Air Inlet Filter ~ Pump Segment ~ Air Inlet Valve ~ 2 Pinch Clamps ~ 1 Roller Clamp ~ Light resistant

260 24 3 50 20 15 5 • •

AdministrationMulti-way oncology sets

04108341419 Multi-way connection set

2305E Multi-way connection set

2306E Multi-way connection set

60950E Alaris® GP Series Oncology,

60952E Alaris® GP Series Oncology, light resistant

MFX72950E Alaris® SE Series Oncology

MFX273-950E Alaris® GW Series Oncology

MFX72952E Alaris® SE Series Oncology, light resistant

MFX273-951E Alaris® GW Series Oncology

MFX273-952E Alaris® GW Series Oncology, light resistant

MFX273-954E Alaris® GW Series Oncology, light light resistant

60953 Alaris® GP Series

60033E Alaris® GP Series

72923-0006 Alaris® SE volumetric pump set

72953-0006 Alaris® SE volumetric pump set

Ala

ris®

SE

Ala

ris®

GW

Ala

ris®

GW

Ala

ris®

GP

Ala

ris®

SE

MFX2307E Multi-way connection set, light resistant

MFX2308E Multi-way connection set, light resistant

60951E Alaris® GP Series Oncology

Ala

ris®

GP

Mu

lti-

way

co

nn

ecti

on

set

s

Page 8: Oncology safety products and closed system solutions · to the SmartSite® needle free port. Single drug therapy The SmartSite® needle-free add on bag access device allows closed

Drip chamber Anti-syphon

valve

Back-check valveInjection PortInjection Y PortSmartSite® Y valve In-line

injection port

Female luerMale luer

SmartSite®

needle free valve

In-line Drip ChamberBox quantity

Male luer

back-check valve

Pinch clamp Roller clamp

Female luer

back-check valve

Female luer

anti-syphon valve

LATEX FreeDEHP FreePVC Free

Key to components

SpikeMicron filterDrops per ml Slide clamp

03508241442 Gravity infusion set

03508411318 Gravity infusion set,

light resistant

Set

Leng

th (

cm)

Prim

ing

volu

me

(ml)

Bore

(m

m)

Qua

ntit

y

Dro

ps p

er m

l

Inlin

e Fi

lter

(µm

)

Drip

Cha

mb

er f

ilter

(µm

)

Fem

ale

luer

bac

k-ch

eck

valv

es

Back

-che

ck v

alve

Smar

tSite

® V

alve

Y P

orts

PVC

fre

e

DEH

P fr

ee

Late

x fr

ee

03508241442 1 Spiked Drip Chamber (Vented/Unvented) ~ Needle-

Free System ~ 1 SmartSite® Valve Y Port ~ Rotating

Male Luer ~ Hydrophobic Air Inlet Filter ~ PVC NODOP

~ 1 Roller Clamp

270 24 3 100 20 15 1 1 • •

03508242442 1 Spiked Drip Chamber (Vented/Unvented) ~ Needle-

Free System ~ Bore 3 mm ~ 2 SmartSite® Valve Y Port

~ Rotating Male Luer ~ Hydrophobic Air Inlet Filter ~

PVC NODOP ~ 1 Roller Clamp

285 26 3 100 20 15 1 2 • •

03508411318 1 Spiked Drip Chamber (Vented/Unvented) ~

Hydrophobic Air Inlet Filter ~ Low Sorbing ~ Light

resistant ~ 1 Roller Clamp155 16 3 100 20 15 • • •

03508317319 1 Spiked Drip Chamber (Vented/Unvented) ~ Vented

Filter ~ Hydrophobic Air Inlet Filter ~ Low Sorbing ~1

Roller Clamp175 20 3 60 20 0.2 • • •

MFX2309E 1 Spike (Vented/Unvented) ~ In-Line Drip Chamber

~ Needle-Free System ~ Hydrophobic Priming Cap ~

Rotating Male Luer ~ Hydrophobic Air Inlet Filter ~

Polyurethane ~ Air Inlet Valve ~ 1 Pinch Clamp ~ 1

Roller Clamp

196 20 3 40 20 15 5 • • •

MFX2310E 1 Spike (Vented/Unvented) ~ In-Line Drip Chamber

~ Needle-Free System ~ Hydrophobic Priming Cap ~

Rotating Male Luer ~ Hydrophobic Air Inlet Filter ~

Polyurethane lined PVC ~ Light resistant ~ Air Inlet

Valve ~ 1 Pinch Clamp ~ 1 Roller Clamp

196 20 3 40 15 5 • •

MFX2311E 1 Spike (Vented/Unvented) ~ In-Line Drip Chamber ~

Needle-Free System ~ Hydrophobic Priming Cap ~

Rotating Male Luer ~ Hydrophobic Air Inlet Filter ~

Polyurethane ~ Air Inlet Valve ~ 1 Pinch Clamp ~ 1

Roller Clamp

190 20 3 40 0.2 5 • • •

MFX2309E Gravity Multi Way set

03508317319 Gravity infusion set

MFX2311E Gravity Multi Way set

AdministrationGravity sets

Gra

vity

Set

s

Page 9: Oncology safety products and closed system solutions · to the SmartSite® needle free port. Single drug therapy The SmartSite® needle-free add on bag access device allows closed

CareFusion UKThe Crescent, Jays Close, BasingstokeHampshire RG22 4BSUnited Kingdom+44 (0)1256 388284 tel0800 917 8776 freephone+44 (0)1256 330860 fax

CareFusion Australia6 Coronation AvenueKings Park NSW 2148AustraliaCustomer Service1800 110 511 tel1800 113 317 fax+61 2 9830 0111 reception

CareFusion AustraliaUnit 3, 167 Prospect HighwaySeven Hills NSW 2147AustraliaCustomer Service1800 110 511 tel1800 113 317 fax+61 2 9624 9000 reception

CareFusion New Zealand14 George Bourke DriveMt Wellington Auckland 10600508 422 734 freephone+64 9 270 2420 reception

CareFusion South AfricaUnit 2 Oude Molen Business ParkOude Molen RoadNdabeniCape Town 7405South Africa+27 21 510 7562 tel+27 21 510 7567 fax

CareFusionPO Box 5527DubaiUnited Arab EmiratesTel: +9714 2822 842Fax: +9714 2822 914

CareFusion Hammarbacken 4BSE-191 24 SollentunaSwedenTel: +46 8 544 43 200Fax: +46 8 544 43 225

CareFusionSolbråveien 10A1383 AskerNorwayTel. +47 66 98 76 00Fax. +47 66 98 76 01

CareFusionDenmarkFirskovvej 25 B2800 LyngbyDenmarkTlf. 70 20 30 74Fax. 70 20 30 98

© 2011 CareFusion Corporation or one of its subsidiaries. All rights reserved. Alaris, Texium and SmartSite are registered trademarks and AccuSlide is a trademark of CareFusion Corporation or one of its subsidiaries.0000CF00263 Issue 2

carefusion.com