Oncology safety products and closed system solutions Alaris ® products
Oncology safety products and closed system solutions
Alaris® products
The risks of oncology from all sidesEvery day, thousands of pharmacists, nurses, physicians and other
caregivers may encounter a serious threat to their own physical and
reproductive health, often without even realizing it.
While the hazardous nature of chemotherapy, antivirals, antibiotics,
hormones and other drugs is well established, it is estimated that
millions of healthcare workers continue to be exposed to these
substances each year.1
Traces of hazardous drugs have been found on floors and counters in
hospital pharmacies, and on chairs and tabletops at the patient bedside.2
More ominously, multiple studies have detected hazardous drugs in the
urine of workers who handled them and also in the urine of workers
who didn’t.3
“Warning: Working with or near hazardous drugs in health care settings may cause skin rashes, infertility, miscarriage, birth defects and possible leukaemia and other cancers.“ 1
Key FactsHarrison (2001) reported that six different drugs (cyclophosphamide, methrotrexate, ifosfamide,
epirubicin, and cisplatin/carboplatin) were detected in the urine of health care workers by 13 of
20 investigations.
CDC/NIOSH 2004-165: Preventing Occupational
Exposures to Antineoplastic and Other
Hazardous Drugs in Health Care Settings
Traces of hazardous drugs have been found on the floors and counters in hospital pharmacies,
and on the chairs and tabletops at the patient bedside.
Minoia et al: Rapid Commun. Mass Spectrom. 12, 1485-1493 (1998)
1. NIOSH report, 2004.2. Minoia et al. 1998; Connor et al. 1999; Pethran et al. 2003.3. Valanis et al. 1991, 1992; Mahon et al. 1994; Nieweg et al. 1994; Ensslin et al. 1994, 1997; Minoia et al. 1998; Wick et al. 2003.
What you can’t see can hurt you
Who is at risk?Exposure risks in the pharmacy
• Reconstituting powdered or lyophilised drugs and further
diluting either the reconstituted powder or concentrated liquid
forms of hazardous drugs using needles
• Expelling air from syringes of hazardous drugs
• Handling contaminated waste
Exposure risks in the patient care area
• Priming or connecting an intravenous administration set
containing a hazardous drug
• Administering a hazardous drug from a syringe
• Handling contaminated waste
When you’re taking care of your cancer patients, you may
be seriously harming yourself at the same time.
When it occursThe above image, photographed under UV light,
illustrates how the standard IV push with needle
and syringe can easily leave unseen dangers
from hazardous drugs to potentially harm the
pharmacist or nurse.
Introducing a closed system solutionCareFusion offers a cost-effective, easy-to-use closed system to help protect healthcare workers anytime they
prepare, transport, administer or dispose of hazardous drugs.
SaferOur Texium® closed male luer and SmartSite® needle-free valve products partner together to form a closed system,
providing leak-free connections and disconnections that help to reduce surface contamination and the risk of
exposure.
SimplerThe luer lock connection of the Texium® closed male luer to a SmartSite® needle-free valve port helps you quickly and
easily achieve a closed system, without adding cumbersome steps to your clinical process.
Complies with NIOSH recommendations Our closed system solution makes it possible for any facility to follow NIOSH recommendations for using closed,
needle-free systems for the safe handling of hazardous drugs.
Your local regulations:
MARCH guidelineHandling and containment from goods received to
clinical areas
Practice Points: preparation areas
• Ensure staff use proprietary containment systems
where possible
Practice Points: clinical areas
• Use proprietary containment systems for
administration where possible
Management and Awareness of Risks of Cytotoxic HandlingHandling and containment from goods received to clinical areasIssue date: 7 June 2007
NIOSH Alert recommendations• When supplemental protection is needed,
use closed system drug transfer devices and
needleless systems inside the ventilated cabinet
• Consider using closed system drug transfer
devices and needleless systems to protect nurses
during drug administration
NIOSH Alert: Preventing Occupational Exposures to Antineoplastic and Other Hazardous Drugs in Health Care SettingsPublication No. 2004–165
Giving you the confidence and security you need to provide care
Exposure risksReconstituting, transporting and administering hazardous
drugs can put health care workers at risk of exposure
to these agents via spillage, surface contamination, and
aerosols. The continued use of needles to draw up and
administer medication also presents a major hazard in
the healthcare environment.
In the Pharmacy
Reconstitution Preparation Transportation
How the Texium® closed male luer works
The Texium® closed male luer is based on
a simple luer-lock principle, allowing free
flow of the drug when connected, and
automatically closing when disconnected.
Together, the Texium® closed male luer
and SmartSite® needle-free valve create an
automatically closed system that helps to
eliminate leakage.
The Texium® closed male luer partners
with any SmartSite® needle-free valve
product to create an easy-to-use, closed
needle-free system.
When connected, the fluid path opens. This
path automatically closes upon disconnection.
The patented no-drip-tip technology of the
Texium® closed male luer creates a vacuum
mechanism when closing to ensure a drip-
free, leak-free disconnection.
The SmartSite® vented vial access device
The hydrophobic air inlet filter minimises
aerosols and neutralises vial pressure, thus
reducing the risks of surface contamination.
3040
506
20
0m
l
Multi-drug therapy
Preparation
using Texium®
closed male luer
and SmartSite®
secondary setMale luer lock with
integrated back check
valve.
The back check valve in
the secondary set helps
to reduce back track of
fluid during the infusion
and it is safely connected
to the SmartSite® needle
free port.
Single drug therapy
The SmartSite® needle-free
add on bag access device
allows closed system
additions of drugs to bag
when used with Texium®
closed male luer.
The Texium® closed male luer has an automatic
safety lock that prevents accidental discharges from
the syringe.
On the Ward
Administration Disposal30
40
50
6
20
0ml
Multi-drug therapy using
the “Quattro system”
Allows the connection of up to
four secondary infusions and
delivery of the drug without any
need to disconnect the sets.
The rigid body reduces risk of
kinking ensuring the drug is
promptly delivered to the patient.
The back check valve in the
secondary set reduces the back
track of fluid during the infusion
and it is safely connected to the
SmartSite® needle free port.
Diluent
The Back check
valve integrated into
the air vent reduces
risk of spillage.
The SmartSite®
needle free valve
maintains the safe
closed system
without needles
or caps.
Secondary set
prepared in
the pharmacy
The Alaris® GP volumetric pump
provides a high level of safety.
Utilising the Alaris® safety clamp
helps reduce the risk of free-flow.
The addition of the Guardrails®
Suite of safety software to the
pump can further help to reduce
harmful IV medication errors and
increase compliance with national
safety standards.
Single Drug Therapy
The SmartSite® needle-free
add on bag access device
connected to primary set.
Bolus – Safe and easy closed system
administration of cytotoxic drug with Texium®
closed male luer and theSmartSite® needle-
free valve Y- port on the administration set.
I.V. Push
With the Alaris® SE
volumetric pump the
patients bedside can be
customised via single or
dual channel capabilities.
The AccuSlide® flow
regulator offers the
benefits of set based free
flow protection.
SmartSite® add-on bag access device
Key performance specifications
Priming Volume:
Needle-free valve port ~ 0.16 mL
Fluid channel ~ 0.61 mL
Compatibility:
Spike adaptor ISO standard spikes
Material: Latex and DEHP-free
Feature Benefit
SmartSite® needle-free valve bag access port
Direct, needle-free access to IV bags for adding or removing fluids
Universal spike adaptor
Fits any ISO standard spike
Partners with Texium® closed male luer for closed system
access to IV bag.
SmartSite® vented vial access device
Partners with Texium® closed male luer for closed system
access to drug vials.
Key performance specifications
Priming Volume:
Total volume in needle-free valve ~ 0.14 mL
and spike when not activated
Residual Volume:
Quantity of fluid remaining in ~ 0.28 mL
vial after withdrawing the maximum
amount through the access port
Filter: 0.2 micron hydrophobic
Material: Latex, DEHP and ABS
plastic-free
Compatibility: 0.2 micron hydrophobic
Feature Benefit
SmartSite® needle-free
Needle free access to multiple use vials
0.2 micron hydrophobic air venting filter
• Neutralizes vial pressure, minimizing aerosols and surface contamination
• Eases drug extraction
• Bacteria retentive
Dual pathway spike Efficiently transfers fluids for maximum extractable volume
Texium® closed male luer
Partners with SmartSite® needle-free valve to achieve a
closed system.
Key performance specifications
Priming Volume:
Total volume in the male luer ~ 0.12 mL
when not activated
Luer flow rate:
Test per ISO 8536-4 guidelines 5948 mL/hr
Internal diameter: 18 gauge
Material: Latex free, DEHP free
and ABS plastic free
Feature Benefit
No-drip-tip technology
• Leak-free transfer of drugs
• Reduces surface contamination
Passive safety system
• Closes upon disconnection
• Reduces surface contamination
• No inadvertent syringe discharge
Lock-and-go design Fast and easy connection to SmartSite® needle-free valve
Vacuum Technology Reduces risk of exposure to hazardous drug when disconnecting from SmartSite® needle-free valve
Secondary infusion sets Multi-way infusion sets SmartSite® needle free valve
Partners with our range of SmartSite®
needle-free secondary sets to achieve a
closed system during administration of
hazardous drugs.
Puts safety first...• No needle
• No caps
• No metal
• Reduces the risk of
needle-stick injuries
• Straight through non-tortuous
fluid path
• High chemical resistance
(lipids and alcohol)
• Cost-effective, MRI compatible,
latex-free IV administration system
• Partners with Texium® closed male
luer for delivering safe and convenient
IV therapy in a closed system
... without the needle
Feature Benefit
SmartSite®
needle-free valve
• Needle-free connection for the preparation of cytotoxic drugs
• Reduces exposure to hazardous drugs
• Maintains closed system
Back check valves • Integration into spike air vent helps prevent spillage of cytotoxic drugs
• Additional back check valve integrated into the luer lock reduces back track of fluid
Hydrophobic cap Facilitates safe and dry priming
Feature Benefit
SmartSite® needle-free
• Needle-free access for the administration of cytotoxic drugs using secondary sets
• Reduces exposure to hazardous drugs
• Maintains closed system
Rigid body • Reduces risk of kinking
• Easier connection of secondary sets
Back check valves Integration into spike air vent helps prevent spillage of cytotoxic drugs
Hydrophobic cap Facilitates safe and dry priming
DEHP free and PVC free
Avoids patient exposure to DEHP
plasticizer
PE-lined • Prevents leaching of phthalates into fluid pathway, reducing patient exposure to DEHP plasticize
• Prevents drug sorption
Used in conjunction with our range of multi-way
infusion sets and safety accessories, ensures a safe,
closed system.
30
40
5 06
20
0m
l
04108362418 Secondary set, vented/unvented
72951NE Secondary set, unvented
72946NE Secondary set, vented/unvented, Light resistant
72947NE Secondary set, unvented, Light resistant
72948NE Secondary set, unvented
MFX2302E Secondary set, vented/unvented
MFX2300E Secondary set light resistant, vented/unvented
MFX2303E Secondary set light resistant, vented/unvented
2300E Bag Spike 2309E Bag Spike,
Back-check valve
10012240 Texium® female cap 10012241 Texium® closed
male luer
10012392
Vented vial
access device
2203E Vial access device 2205E Vial access device
10013365 SmartSite® Add on
bag access device
Set
Leng
th (
cm)
Prim
ing
volu
me
(ml)
Qua
ntit
y
Smar
tSite
® n
eedl
e fr
ee v
alve
s
PVC
fre
e
DEH
P fr
ee
Late
x fr
ee
10012240 Texium® Safety Disposables ~ PushFit Cap 100 • • •
10012241 Priming Volume 0.12 ml ~ Texium® Safety
Disposables 0.12 100 • • •
10012392 Needle-free system ~ Hydrophobic Air Inlet
Filter ~ Vial Access Device Diameter 20 mm 0.14 80 1 • • •
MFX2594E Transfer Spike(s) (Vented) ~ Needle-Free System
~ Dispensing Pin ~ Hydrophobic Air Inlet Filter6.7 0.1 100 1 • • •
2203E Needle-free system ~
Vial Access Device Diameter 13 mm3.5 0.08 100 1 • • •
2205E Needle-free system ~
Vial Access Device Diameter 20 mm 3.5 0.09 100 • • •
10013365 1 Spike (Unvented) ~ Bag Access Device ~
Needle-free system ~ PVC NODOP ~ Spike Port
Adaptor
9.6 0.61 100 1 • •
2300E 1 Spike (Unvented) ~ Bag Access Device ~
Needle-free system0.47 100 1 • • •
2309E 1 Spike (Unvented) ~ Bag Access Device ~
Needle-free system ~ 1 Back-check Valve13.35 0.9 100 1 • •
Texium® closed male luer
Vial Access devices
Bag Access devices
Texi
um
® c
lose
d
mal
e lu
erV
ial
Acc
ess
dev
ices
Bag
A
cces
s d
evic
es
MFX2594E Dispensing pin
Reconstitution
Set
Leng
th (
cm)
Prim
ing
volu
me
(ml)
Bore
(m
m)
Qua
ntit
y
Dro
ps p
er m
l
Inlin
e Fi
lter
(µm
)
Hyd
roph
obic
Prim
ing
Cap
Air
Inle
t V
alve
Mal
e lu
er b
ack-
chec
k va
lve
Smar
tSite
® V
alve
Y P
orts
PVC
fre
e
DEH
P fr
ee
Late
x fr
ee
04108362418 1 Spike (Vented/Unvented) ~ Rotating Male Luer(s) ~ Hydrophobic Air Inlet Filter ~ Needle-Free System
31 2.3 3 100 • 1 • •
72951NE 1 Spike (Unvented) ~ Needle-Free System ~ PVC NODOP ~ 1 Pinch Clamp 35 3 3 100 • 1 1 • •
72946NE 1 Spike (Vented/Unvented) ~ Rotating Male Luer(s) ~ Hydrophobic Air Inlet Filter ~ Needle-Free System~ Light resistant ~ PVC NODOP ~ Hydrophobic cap ~ 1 Pinch Clamp
31 2.3 3 50 • 1 • •
72947NE 1 Spike (Unvented) ~ Needle-free system ~ PVC NODOP ~ Light resistant ~ 1 Pinch Clamp ~ Hydrophobic cap
35 3 3 50 • 1 1 • •
72948NE 1 Spike (Unvented) ~ Needle-Free System~ PVC NODOP ~ 2 Pinch Clamps ~ Hydrophobic cap 50 6 3 50 0.2 • 1 1 • •
MFX2302E 1 Spike (Vented/Unvented) ~ Needle-Free System ~ Vented Filter ~ Hydrophobic Air Inlet Filter ~ Polyurethane ~ 1 Pinch Clamp
55 4.1 3 50 0.2 • • 1 1 • • •
MFX2301E 1 Spike (Vented/Unvented) ~ Needle-Free System ~ Hydrophobic Air Inlet Filter ~ Polyurethane ~ 1 Pinch Clamp
41 2 3 50 • • 1 1 • • •
MFX2300E 1 Spike (Vented/Unvented) ~ Needle-Free System ~ Hydrophobic Air Inlet Filter ~ Low sorbing ~ Polyethylene lined PVC ~ Light resistant ~ 1 Pinch Clamp
41 2 3 50 • • 1 1 • •
MFX2303E 1 Spike (Vented/Unvented) ~ Needle-Free System ~ Flow Controller ~ Hydrophobic Air Inlet Filter ~ Low sorbing ~ Polyethylene lined PVC ~ Light resistant ~ 1 Pinch Clamp
47 2.4 3 50 • • 1 1 • •
MFX2304E Needle-Free System ~ Male luer lock to male luer lock connecting line ~ Polyurethane ~ 1 Pinch Clamp
35 2.1 3 50 • 1 1 • • •
PreparationSecondary sets
Seco
nd
ary
sets
Model Number: 72951NEArtwork Number: 1000AW02971
CO Number Change Description Drawn by7131 Introduction AWC10793 Update spike AWC
Change HistoryIssue Date
12
29/08/0623/06/10
Set
Leng
th (
cm)
Prim
ing
volu
me
(ml)
Bore
(m
m)
Qua
ntit
y
Dro
ps p
er m
l
Inlin
e Fi
lter
(µm
)
Drip
Cha
mbe
r fil
ter
(µm
)
Fem
ale
luer
bac
k-ch
eck
valv
es
Back
-che
ck v
alve
Smar
tSite
® V
alve
Y P
orts
PVC
fre
e
DEH
P fr
ee
Late
x fr
ee
MFX72950E 1 Spike (Vented/Unvented) ~ In-Line Drip Chamber ~ Needle-Free System ~ Hydrophobic Priming Cap ~ Rotating Male Luer ~ Hydrophobic Air Inlet Filter ~ Air Inlet Valve ~ AccuSlide
™ Flow Regulator ~ PVC NODOP ~ Polyurethane ~ 3
Pinch Clamps ~ 1 Roller Clamp
265 29 3 35 20 15 5 • •
MFX72952E 1 Spike (Vented/Unvented) ~ In-Line Drip Chamber ~ Needle-Free System ~ Hydrophobic Priming Cap ~ Rotating Male Luer ~ Hydrophobic Air Inlet Filter ~ Air Inlet Valve ~ AccuSlide
® Flow
Regulator ~ Low sorbing ~ PVC NODOP ~ Polyethylene lined PVC ~ Light resistant ~ 3 Pinch Clamps ~ 1 Roller Clamp
265 29 3 35 20 15 5 • •
MFX273-950E 1 Spike (Vented/Unvented) ~ In-Line Drip Chamber ~ Needle-Free System ~ Hydrophobic Priming Cap ~ Rotating Male Luer ~ Hydrophobic Air Inlet Filter ~ Air Inlet Valve ~ In-Line Back-check valve ~ Polyurethane ~ 3 Pinch Clamps ~ 1 Roller Clamp
265 29 3 35 20 15 • 5 •
MFX273-951E 1 Spike (Vented/Unvented) ~ In-Line Drip Chamber ~ Needle-Free System ~ Hydrophobic Priming Cap ~ Rotating Male Luer ~ Hydrophobic Air Inlet Filter ~ Air Inlet Valve ~ In-Line Back-check valve ~ Polyurethane ~ 3 Pinch Clamps ~ 1 Roller Clamp
265 29 3 35 20 15 • 3 •
MFX273-952E 1 Spike (Vented/Unvented) ~ In-Line Drip Chamber ~ Needle-Free System ~ Hydrophobic Priming Cap ~ Rotating Male Luer ~ Hydrophobic Air Inlet Filter ~ Air Inlet Valve ~ In-Line Back-check valve ~ PE/PVC NODOP ~ 3 Pinch Clamps ~ 1 Roller Clamp
265 29 3 35 20 15 • 5 •
MFX273-954E 1 Spike (Vented/Unvented) ~ In-Line Drip Chamber ~ Needle-Free System ~ Hydrophobic Priming Cap ~ Rotating Male Luer ~ Hydrophobic Air Inlet Filter ~ Air Inlet Valve ~ In-Line Back-check valve ~ PE/PVC NODOP ~ 3 Pinch Clamps ~ 1 Roller Clamp
265 29 3 35 20 15 • 3 •
AdministrationMulti-way oncology sets
60033E 1 Spiked Drip Chamber (Vented/Unvented) ~ Needle-Free System ~ Vented Filter ~ 2 SmartSite
® Valve Y Ports ~ Alaris
® Safety Clamp
Hydrophobic Air Inlet Filter ~ Silicone pump segment ~ Low Sorbing ~ Polyethylene lined PVC ~ 1 Pinch Clamp ~ 1 Roller Clamp
265 25 2.7 50 20 0.2 2 • •
60953 1 Spiked Drip Chamber (Vented/Unvented) ~ Alaris® Safety Clamp ~
Hydrophobic Air Inlet Filter ~ Silicone pump segment ~ Low Sorbing ~ Polyethylene lined PVC ~ 1 Pinch Clamp ~ 1 Roller Clamp
260 24 3 80 20 15 • •
72923- 0006
1 Spiked Drip Chamber (Vented/Unvented) ~ Vented Filter ~ Rotating Male Luer ~ Hydrophobic Air Inlet Filter ~ AccuSlide
®
Flow Regulator ~ Silicone pump segment ~ Low Sorbing ~ Polyethylene lined PVC
284 23 2.7 50 20 0.2 •
72923E- 0006
1 Spiked Drip Chamber (Vented/Unvented) ~ Vented Filter ~ Rotating Male Luer ~ Hydrophobic Air Inlet Filter ~ AccuSlide
®
Flow Regulator ~ Silicone pump segment ~ Low Sorbing ~ Polyethylene lined PVC ~ Needle-Free System
300 26 2.7 50 20 0.2 1 •
72953- 0006
1 Spiked Drip Chamber (Vented/Unvented) ~ Rotating Male Luer(s) ~ Hydrophobic Air Inlet Filter ~ AccuSlide
® Flow Regulator ~
Silicone pump segment ~ Low Sorbing ~ Polyethylene lined PVC279 22 2.7 20 20 •
Single-drug oncology sets
Set
Leng
th (
cm)
Prim
ing
volu
me
(ml)
Bore
(m
m)
Qua
ntit
y
Dro
ps p
er m
l
Inlin
e Fi
lter
(µm
)
Drip
Cha
mbe
r fil
ter
(µm
)
Fem
ale
luer
bac
k-ch
eck
valv
es
Back
-che
ck v
alve
Smar
tSite
® V
alve
Y P
orts
PVC
fre
e
DEH
P fr
ee
Late
x fr
ee
04108341419 1 Spike (Vented/Unvented) ~ Hydrophobic Air Inlet Filter ~ PVC NODOP ~ Spike Port Adaptor ~ 1 Pinch Clamp
26 3.2 3 100 4 • •
2305E 1 Spike (Vented/Unvented) ~ transparent ~ Needle-free system ~ Hydrophobic Air Inlet Filter ~ Spike Port Adaptor ~ Air Inlet Valve ~ 1 Pinch Clamp
30 2 3 60 4 • •
MFX2307E 1 Spike (Vented/Unvented) ~ Needle-Free System ~ Hydrophobic Air Inlet Filter ~ Low Sorbing ~ PVC NODOP~ Polyethylene lined PVC ~ Light resistant ~ Spike Port Adaptor ~ Air Inlet Valve ~ 1 Pinch Clamp
30 2 3 60 4 • •
2306E 1 Spike (Vented/Unvented) ~ transparent ~ Needle-free system ~ Hydrophobic Air Inlet Filter ~ Spike Port Adaptor ~ Air Inlet Valve ~ 1 Pinch Clamp
25 2 3 60 2 • •
MFX2308E 1 Spike (Vented/Unvented) ~ Needle-Free System ~ Hydrophobic Air Inlet Filter ~ Low Sorbing ~ PVC NODOP~ Polyethylene lined PVC ~ Light resistant ~ Spike Port Adaptor ~ Air Inlet Valve ~ 1 Pinch Clamp
26 1.7 3 60 2 • •
60950E 1 Spike (Vented/Unvented) ~ In-Line Drip Chamber ~ Needle-Free System ~ Hydrophobic Priming Cap ~ Rotating Male Luer ~ Alaris® Safety Clamp ~ Hydrophobic Air Inlet Filter ~ Pump Segment ~ Air Inlet Valve ~ 2 Pinch Clamps ~ 1 Roller Clamp
260 24 3 50 20 15 5 • •
60951E 1 Spike (Vented/Unvented) ~ In-Line Drip Chamber ~ Needle-Free System ~ Hydrophobic Priming Cap ~ Rotating Male Luer ~ Alaris® Safety Clamp ~ Hydrophobic Air Inlet Filter ~ Pump Segment ~ Air Inlet Valve ~ 2 Pinch Clamps ~ 1 Roller Clamp
260 24 3 50 20 15 3 • •
60952E 1 Spike (Vented/Unvented) ~ In-Line Drip Chamber ~ Needle-Free System ~ Hydrophobic Priming Cap ~ Rotating Male Luer ~ Alaris® Safety Clamp ~ Hydrophobic Air Inlet Filter ~ Pump Segment ~ Air Inlet Valve ~ 2 Pinch Clamps ~ 1 Roller Clamp ~ Light resistant
260 24 3 50 20 15 5 • •
AdministrationMulti-way oncology sets
04108341419 Multi-way connection set
2305E Multi-way connection set
2306E Multi-way connection set
60950E Alaris® GP Series Oncology,
60952E Alaris® GP Series Oncology, light resistant
MFX72950E Alaris® SE Series Oncology
MFX273-950E Alaris® GW Series Oncology
MFX72952E Alaris® SE Series Oncology, light resistant
MFX273-951E Alaris® GW Series Oncology
MFX273-952E Alaris® GW Series Oncology, light resistant
MFX273-954E Alaris® GW Series Oncology, light light resistant
60953 Alaris® GP Series
60033E Alaris® GP Series
72923-0006 Alaris® SE volumetric pump set
72953-0006 Alaris® SE volumetric pump set
Ala
ris®
SE
Ala
ris®
GW
Ala
ris®
GW
Ala
ris®
GP
Ala
ris®
SE
MFX2307E Multi-way connection set, light resistant
MFX2308E Multi-way connection set, light resistant
60951E Alaris® GP Series Oncology
Ala
ris®
GP
Mu
lti-
way
co
nn
ecti
on
set
s
Drip chamber Anti-syphon
valve
Back-check valveInjection PortInjection Y PortSmartSite® Y valve In-line
injection port
Female luerMale luer
SmartSite®
needle free valve
In-line Drip ChamberBox quantity
Male luer
back-check valve
Pinch clamp Roller clamp
Female luer
back-check valve
Female luer
anti-syphon valve
LATEX FreeDEHP FreePVC Free
Key to components
SpikeMicron filterDrops per ml Slide clamp
03508241442 Gravity infusion set
03508411318 Gravity infusion set,
light resistant
Set
Leng
th (
cm)
Prim
ing
volu
me
(ml)
Bore
(m
m)
Qua
ntit
y
Dro
ps p
er m
l
Inlin
e Fi
lter
(µm
)
Drip
Cha
mb
er f
ilter
(µm
)
Fem
ale
luer
bac
k-ch
eck
valv
es
Back
-che
ck v
alve
Smar
tSite
® V
alve
Y P
orts
PVC
fre
e
DEH
P fr
ee
Late
x fr
ee
03508241442 1 Spiked Drip Chamber (Vented/Unvented) ~ Needle-
Free System ~ 1 SmartSite® Valve Y Port ~ Rotating
Male Luer ~ Hydrophobic Air Inlet Filter ~ PVC NODOP
~ 1 Roller Clamp
270 24 3 100 20 15 1 1 • •
03508242442 1 Spiked Drip Chamber (Vented/Unvented) ~ Needle-
Free System ~ Bore 3 mm ~ 2 SmartSite® Valve Y Port
~ Rotating Male Luer ~ Hydrophobic Air Inlet Filter ~
PVC NODOP ~ 1 Roller Clamp
285 26 3 100 20 15 1 2 • •
03508411318 1 Spiked Drip Chamber (Vented/Unvented) ~
Hydrophobic Air Inlet Filter ~ Low Sorbing ~ Light
resistant ~ 1 Roller Clamp155 16 3 100 20 15 • • •
03508317319 1 Spiked Drip Chamber (Vented/Unvented) ~ Vented
Filter ~ Hydrophobic Air Inlet Filter ~ Low Sorbing ~1
Roller Clamp175 20 3 60 20 0.2 • • •
MFX2309E 1 Spike (Vented/Unvented) ~ In-Line Drip Chamber
~ Needle-Free System ~ Hydrophobic Priming Cap ~
Rotating Male Luer ~ Hydrophobic Air Inlet Filter ~
Polyurethane ~ Air Inlet Valve ~ 1 Pinch Clamp ~ 1
Roller Clamp
196 20 3 40 20 15 5 • • •
MFX2310E 1 Spike (Vented/Unvented) ~ In-Line Drip Chamber
~ Needle-Free System ~ Hydrophobic Priming Cap ~
Rotating Male Luer ~ Hydrophobic Air Inlet Filter ~
Polyurethane lined PVC ~ Light resistant ~ Air Inlet
Valve ~ 1 Pinch Clamp ~ 1 Roller Clamp
196 20 3 40 15 5 • •
MFX2311E 1 Spike (Vented/Unvented) ~ In-Line Drip Chamber ~
Needle-Free System ~ Hydrophobic Priming Cap ~
Rotating Male Luer ~ Hydrophobic Air Inlet Filter ~
Polyurethane ~ Air Inlet Valve ~ 1 Pinch Clamp ~ 1
Roller Clamp
190 20 3 40 0.2 5 • • •
MFX2309E Gravity Multi Way set
03508317319 Gravity infusion set
MFX2311E Gravity Multi Way set
AdministrationGravity sets
Gra
vity
Set
s
CareFusion UKThe Crescent, Jays Close, BasingstokeHampshire RG22 4BSUnited Kingdom+44 (0)1256 388284 tel0800 917 8776 freephone+44 (0)1256 330860 fax
CareFusion Australia6 Coronation AvenueKings Park NSW 2148AustraliaCustomer Service1800 110 511 tel1800 113 317 fax+61 2 9830 0111 reception
CareFusion AustraliaUnit 3, 167 Prospect HighwaySeven Hills NSW 2147AustraliaCustomer Service1800 110 511 tel1800 113 317 fax+61 2 9624 9000 reception
CareFusion New Zealand14 George Bourke DriveMt Wellington Auckland 10600508 422 734 freephone+64 9 270 2420 reception
CareFusion South AfricaUnit 2 Oude Molen Business ParkOude Molen RoadNdabeniCape Town 7405South Africa+27 21 510 7562 tel+27 21 510 7567 fax
CareFusionPO Box 5527DubaiUnited Arab EmiratesTel: +9714 2822 842Fax: +9714 2822 914
CareFusion Hammarbacken 4BSE-191 24 SollentunaSwedenTel: +46 8 544 43 200Fax: +46 8 544 43 225
CareFusionSolbråveien 10A1383 AskerNorwayTel. +47 66 98 76 00Fax. +47 66 98 76 01
CareFusionDenmarkFirskovvej 25 B2800 LyngbyDenmarkTlf. 70 20 30 74Fax. 70 20 30 98
© 2011 CareFusion Corporation or one of its subsidiaries. All rights reserved. Alaris, Texium and SmartSite are registered trademarks and AccuSlide is a trademark of CareFusion Corporation or one of its subsidiaries.0000CF00263 Issue 2
carefusion.com