  • SUNWAVE OMT USER MANUAL

    SUNWAVE Repeater

    OMT User Manual V3.02.04

    SUNWAVE COMMUNICATION CO., LTD.

    SUNWAVE COMMUNICATION CO., LTD 1

  • SUNWAVE OMT USER MANUAL

    CONTENT 1. OMT Installation....................................................................................................... 3

    Hardware ............................................................................................................. 3 Installation procedure........................................................................................ 3

    2. Operation ................................................................................................................ 7

    Hardware Preparation....................................................................................... 7 Start Program....................................................................................................... 7

    Remote Connection... 8 Local Connection (use data cable connection) 14

    SUNWAVE COMMUNICATION CO., LTD 2

  • SUNWAVE OMT USER MANUAL

    1. OMT Installation After installation of the repeater, the Operation & Maintenance Terminal shall be used to initialize and control the repeater setups by enquiring, changing and monitoring over various repeater sites and engineering parameters. OMT can be connected by local, remote data or SMS modes, allowing real time monitoring and maintenance over repeaters. Hardware

    Minimum Hardware configuration for OMT installation

    100MHz Intel CPU 32M RAM 32M Disc free space COM Port Hays Modem Windows 95/98 or Windows NT4.0, Service Pack 3 or above

    Installation procedure Make sure there is no other application running, and:

    Insert the CD-ROM and auto run setup.exe installation file. If the auto run file is not started, open the CD-ROM directory and click

    setup.exe to start installation.

    Press Next on Welcome window. See Figure 1-1.

    SUNWAVE COMMUNICATION CO., LTD 3

  • SUNWAVE OMT USER MANUAL

    Figure 1-1

    2). Select the installation path. See Figure 1-2

    Figure 1-2

    SUNWAVE COMMUNICATION CO., LTD 4

  • SUNWAVE OMT USER MANUAL

    3). Click Install, as Figure 1-3.

    Figure 1-3

    4). Click Install the Drive. See Figure 1-4.

    Figure 1-4

    5). Click finish to end the installation. As Figure 1-5

    SUNWAVE COMMUNICATION CO., LTD 5

  • SUNWAVE OMT USER MANUAL

    Figure 1-5

    6). Configure the System Config as you wish.

    SUNWAVE COMMUNICATION CO., LTD 6

  • SUNWAVE OMT USER MANUAL

    2. Operation This part introduces how to configure and setup for local and remote connection for

    repeater using OMT.

    Hardware Preparation Follow the next steps:

    Local Control:

    1. Turn on the repeater.

    2. Turn on the PC.

    3. Connect PC to the RS232 serial port in repeater

    with RS232 Data cable. Set the COM Port in use

    in OMT. Press Connect to connect OMT/PC and

    Repeater.

    Remote Control:

    1. Connect OMT/PC and the modem with PC.

    2. Install a SIM card and turn on the repeater

    3. Turn on the modem and PC

    Start Program Start OMT. Choose OMT from Start menu, or double click the OMT icon on desktop.

    The window See Figure 1-6 pops up after running the program.

    SUNWAVE COMMUNICATION CO., LTD 7

  • SUNWAVE OMT USER MANUAL

    Figure 1-6

    Remote Connection:

    1). Click system Connect Config see Figure 1-7

    Figure 1-7

    2). Configure the Connection Config as Figure 1-8:

    SUNWAVE COMMUNICATION CO., LTD 8

  • SUNWAVE OMT USER MANUAL

    z Choose the right monitoring way as SMS(NMS). z Choose the Modem Type. Suppose it is a GSM repeater, then select GSM.

    choose China Telecom CDMA if it is CDMA repeater. z Add the SIM card(In the repeater) number on the Modem Type. z Choose the correct Com Number according to the Device Manager of PC

    Hardware as showed Figure 1-9

    Figure 1-8

    Figure 1-9

    3). Click Identify to connect the repeater. See Figure 1-10, after that, see Figure 1-11

    SUNWAVE COMMUNICATION CO., LTD 9

  • SUNWAVE OMT USER MANUAL

    Figure 1-10

    Figure 1-11 4). Enter the factory state, as Figure 1-12

    SUNWAVE COMMUNICATION CO., LTD 10

  • SUNWAVE OMT USER MANUAL

    Figure 1-12

    5). Set the Query/Control Phone No.1 and Alarm Phone No.1 as the SIM card number inside the modem connecting with OMT. See Figure 1-13

    Figure 1-13

    6). How to Query data. z Select the item you want query, click query. As Figure 1-14

    SUNWAVE COMMUNICATION CO., LTD 11

  • SUNWAVE OMT USER MANUAL

    Figure 1-14

    7). How to set data. z Click the blank area on set value. After set the right value, click set to finish the

    setup. See Figure 1-15

    Figure 1-15

    SUNWAVE COMMUNICATION CO., LTD 12

  • SUNWAVE OMT USER MANUAL

    z Example 1. Set the FA channel switch. -select FA CH Setting under Setting. Choose the needed channel. As Figure 1-16

    Figure 1-16

    z Example 2. Set Through Mode. Once the Through mode on, then the ICM will be

    Bypass. If it is off, then ICM work normally. See Figure 1-17

    Figure 1-17

    SUNWAVE COMMUNICATION CO., LTD 13

  • SUNWAVE OMT USER MANUAL

    z Example 3. Set ICM Setting. Turn on the DL/UL Cancellation Mode to turn on the ICM. As Figure 1-18

    Figure 1-18

    Local Connection (use data cable connection):

    1). Click system Connect Config see Figure 1-19

    Figure 1-19

    SUNWAVE COMMUNICATION CO., LTD 14

  • SUNWAVE OMT USER MANUAL

    2). Configure the Connection Config as Figure 1-20: z Choose the right monitoring way as Local (monitor with data cable) z Choose the correct Com Number according to the Device Manager of PC

    Hardware as showed Figure 1-21

    Figure 1-20

    Figure 1-21

    The rest part (query and set) is totally same as the remote monitoring.

    SUNWAVE COMMUNICATION CO., LTD 15

  • SUNWAVE OMT USER MANUAL

    Note: 1. When use remote monitoring (SMS). It is better query one data per time to ensure the

    rapid feedback. It is not suggest to Select All. 2. For the remote monitoring using CDMA modem. Sunwave OMT just support few

    CDMA Modem by now. Like ZTE AC 2736. 3. Enter the factory mode first before you want to set the data.

    SUNWAVE COMMUNICATION CO., LTD 16

    1. OMT InstallationHardware Installation procedure

    2. Operation Hardware Preparation Start ProgramRemote Connection:Local Connection (use data cable connection):