Jensen Technologies, LLC Laboratory Services Fee Schedule Torch Fire Assaying Effective January1, 2012 15985 South Golden Road, Unit H Golden, CO 80401 Phone: (303) 478-3929 e-mail:[email protected] Website: www.jensentechnologiesllc.com 1
11

OCR Document - Jensen Technologies LLCjensentechnologiesllc.com/Files/TorchAssayingBrochure12... · Web view" or ash, which joins the molten borax glass as a slag, for disposal. The

Apr 13, 2018

Download

Documents

phamkiet
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: OCR Document - Jensen Technologies LLCjensentechnologiesllc.com/Files/TorchAssayingBrochure12... · Web view" or ash, which joins the molten borax glass as a slag, for disposal. The

Jensen Technologies, LLC

Laboratory Services Fee Schedule

Torch Fire AssayingEffective January1, 2012

15985 South Golden Road, Unit HGolden, CO 80401

Phone: (303) 478-3929e-mail:[email protected]

Website: www.jensentechnologiesllc.com

1

Page 2: OCR Document - Jensen Technologies LLCjensentechnologiesllc.com/Files/TorchAssayingBrochure12... · Web view" or ash, which joins the molten borax glass as a slag, for disposal. The

Jensen Technologies Lab has developed a Torch Fire Assaying Procedure.

Torch Fire Assaying Technique

Charles Butler at Butler Lab has developed an assay procedure to be used as a supplement to furnace assaying of the noble metal ores. It is quick and inexpensive, with most assays requiring 15 to 20 minutes. (Reprinted from Butler Lab Website www.butlerlab.com)

It is an excellent prospect tool and field guide for the drilling crews. It can also be used to assay mill run samples and tails, leach solutions, chemical precipitates and any of the noble metallic salts, including silver, gold and the platinum group metals. It is ideal for assaying wet or dry concentrates from one's recovery system and the flow water being used in said system. This water, when working with ores carrying water soluble values, will carry away a portion of one's values unless steps are taken to save them.

The infinite number of possible torch flame settings allows one to create the reductive or oxidizing flames when they are required. As a result, only two fluxes are required and we seldom have a failure. When difficulties do arise, we are made aware of it within a minute or so, allowing the assayer a chance to make any needed adjustments of the torch, or the addition of either type flux.

1. When assaying for the "noble metals", in order to free our metallic values, one must create a liquid fusion of the "assay charge". We do this by mixing our crushed sample with the proper assay flux and placing same inside a crucible. Then, with our oxy-acetylene torch adjusted to the proper oxygen to acetylene ratio, we create the "reductive flame" required to liquefy the assay. The intense heat from the torch, applied directly down over the assay, creates temperatures in excess of 2,000 degrees centigrade, enabling one to recover all of the noble metals, if present. 2. One needs a "collector" to collect and hold any liquefied gold, silver or platinum group values the tested sample may have contained. We accomplish this with one of our flux ingredients, "litharge" a lead oxide powder. When performing correctly, heat from our reductive torch flame changes this litharge to liquefied lead. This lead alloys, or combines with all the molten noble metals, except osmium, one of the platinum groups. When assaying specifically for the platinum metals, most assayers add a silver "inquart", either as foil or wire, to act as their collector, as silver does alloy with all platinum group metals. In addition, the

2

Page 3: OCR Document - Jensen Technologies LLCjensentechnologiesllc.com/Files/TorchAssayingBrochure12... · Web view" or ash, which joins the molten borax glass as a slag, for disposal. The

extreme effects the PGM's have on the silver "beads", makes for easy recognition that platinum metals are present.

3. The fusion procedure must produce a 1/8 to 5/32 inch diameter lead "button". This lead will start to appear as real small, shiny beads, within the first 30 to 40 seconds, after applying the reductive torch flame to the assay charge, if everything is working as planned. Failure to observe any tiny lead beads, indicates "trouble". A few difficult ores do require the adding of a second measure of assay flux. When fusion is complete (everything liquefied) and all lead has settled to the bottom of the crucible, we dump the "slag", leaving the lead button in the crucible for "scorification".

4. This step is the scorifying of the lead button to remove any "base metals" (metals other than noble metals) that were picked up by the molten lead. This is performed by adding a small pinch of borax glass, then applying a highly oxidizing torch flame. The lead button will catch on fire, burning at over 3,000 degrees centigrade. This high heat changes all base metals to "scoria" or ash, which joins the molten borax glass as a slag, for disposal. The somewhat smaller lead button, containing any noble metal values that were present, is dumped out onto an aluminum plate for cooling.

Gold Bead

3

Page 4: OCR Document - Jensen Technologies LLCjensentechnologiesllc.com/Files/TorchAssayingBrochure12... · Web view" or ash, which joins the molten borax glass as a slag, for disposal. The

Gold Dore Beads (Placer)

5. The next step is to "cupel" the button, to dispose of the lead. Our cupels are small, bone ash cups. Their porosity adsorbs the liquid litharge, created by the oxidizing of the lead button, with the oxidizing torch flame. Cupelling is complete, when the button, growing smaller, becomes a bead, refusing to reduce in size any further. After the torch is withdrawn, most beads will "blick", or flash, just as they begin to cool, at the very instant they change from liquid to a solid. These beads are referred to as "dore beads", as they may contain any or all of the noble metals, silver, gold, platinum, palladium, iridium, osmium, rhodium and ruthenium. The assayer must determine which, with additional testing.

All measurements and computations are based on the volumetric principal, instead of by weight. This, since scales sufficiently accurate for this work would be very expensive and inappropriate

4

Page 5: OCR Document - Jensen Technologies LLCjensentechnologiesllc.com/Files/TorchAssayingBrochure12... · Web view" or ash, which joins the molten borax glass as a slag, for disposal. The

for outdoor use. A small, accurately calibrated spoon is used to measure out the material to be tested. A spoon five times larger is used for measuring the flux. The noble metals are recovered as a small, round bead, its diameter is measured with a 40X power, optical comparator, rather than weigh them, to determine the value of the ore which produced them. Through measurement and the use of our "discoloring solution", most ores can be evaluated. However, some beads do require "parting" with nitric acid and distilled water to remove the silver, then rebeaded, before their ore can be evaluated. The discoloring procedure lets us know when parting is necessary. Actually, parting is seldom required, as at least 90% of one's tests can be evaluated through use of natural observation and the "Bead Discoloring Procedure". It readily identifies all beads containing 75%, or more, silver and lets one know the approximate silver content, ranging from 75% to 100%. The results are expressed in "Troy Ounces" of silver or gold and platinum group metals per ton of materials being assayed.The following facts, comparing the torch assay procedure with the conventional, furnace fire assay, will further indicate the different ways in which this technique has advanced the art for the prospector and miner.

l. There is no massive furnace to be heated, only a small assay weighing a few grams and a two ounce crucible. 2. The "fusion charge", in the conventional assay, just lies there, within the crucible, without benefit of any appreciable mechanical stirring to assure that the molten lead will come into contact with the entire melt, during fusion. In our method, the crucible is manually rocked around in a circular motion, and in addition, the flame is used to stir the melt, assuring complete alloying of the lead and any noble metals contained within.

3. The method eliminates removal of any tiny beads from the cupels, cleaning and weighing them. This is a tedious task, at best.

4. The entire process is carried out under one's visual observation, from start to finish. This allows for the immediate adjustment, if necessary to correct for conditions caused by some troublesome ores.

5. The light weight, mobile equipment can be taken to a field site if needed.

6. With the Torch Assay Procedure, one can develop, prove and promote his gold, silver or platinum property.

8. Probably, the most important feature is the fact that one receives an answer within minutes, instead of hours, days, or weeks.

5

Page 6: OCR Document - Jensen Technologies LLCjensentechnologiesllc.com/Files/TorchAssayingBrochure12... · Web view" or ash, which joins the molten borax glass as a slag, for disposal. The

Jensen Technologies is developing a PMA XRF Analyzer and GF-AAS to assay the small bead for Au, Ag, and PGM directly.

Priority ServiceRoutine analyses are normally completed within 5 working days.Samples arriving after 3:00 pm are logged into our system on the following business day.

When our analysis load permits, priority services are available for an additional charge. These services do not guarantee results within the number of days specified as some procedures or combinations of procedures require additional time. Priority service does insure that your samples will be prioritized over standard service samples. Priority services require prior arrangement to insure availability. Projects requiring exceptional levels of effort may be subject to additional surcharges.

Priority Service 25% surcharge

Sample Preparation

Crushing, Splitting, Pulverization (-200 Mesh)----------------------------------------------------------------------$20/sample

Geological, Metallurgical, Geochemical, Process Samples, Solutions

Au/Ag (Torch Fire Assay (Duplicate Analysis recommended)------------------------------------------------$50/sample

Digital Micro Photograph (Bead) -------------------------------------------------------------------------------------- $20/sample

ORDERING INFORMATIONGENERALPlease complete either our Analysis Request Form on page 8.) or supply the following information on your company's stationery: 1. Purchase Order Number.

2. Reporting and billing addresses.3. Reporting phone number, FAX number and/or email address 4. Street address for sample return. 5. Sample I.D.6. Analyses requested.7. Information about the chemical structure and physical properties of all samples submitted for

analysis 9. Any hazards associated with the samples

10. Sample disposal information (see below)

Samples arriving after 3:00 pm. will be logged into our system on the next business day. Jensen Technologies reserves the right to refuse to receive or analyze samples that are deemed to be unsafe to handle in our facilities or for any other reason.

SAMPLE QUANTITY REOUIREDExcept for some physical tests and water determinations, a few grams of sample are typically an adequate amount for most torch fire assays.

Check with Jensen Technologies to verify the sample quantities and/or handling required for analysis..

6

Page 7: OCR Document - Jensen Technologies LLCjensentechnologiesllc.com/Files/TorchAssayingBrochure12... · Web view" or ash, which joins the molten borax glass as a slag, for disposal. The

ANALYSIS REPORTSAnalysis reports are normally sent by e-mail. Upon request, reports will be provided by telephone, hard copy, or FAX at no additional charge. Inquire about other reporting formats.

All results are held in strict confidence. Results will be released to a third party only when authorized by the original client.

QUOTATIONSWritten quotations are available to secure pricing for projects and special analyses. These quotations are valid for 30 days unless otherwise noted. .

SAMPLE STORAGE, RETURN and DISPOSAL All samples remain the property of the clientAny unused portion of a sample will be returned unless the client certifies that the sample can properly be disposed of in the municipal waste system (landfill or sewer). A fee of $3.00 per sample (minimum $10.00 per order) will be billed for all returned samples. Samples are normally held for 30 days after reporting.

PRICING POLICY

It is the policy of Jensen Technologies to set prices at a fair and equitable level for quality analytical services.While we attempt to maintain the listed rates, the prices are subject to change without notice. Specific test methods and pricing may not be applicable to all sample types. In these cases the customer will be notified and, if appropriate, a special price quotation will be provided.

DISCOUNTSDiscounts may be available for large quantities of samples.Contact Jensen Technologies for more information.

PAYMENTPayment for services must accompany order unless credit is arranged.We accept cash or check for payment of services.

LIMITS OF LIABILITY AND WARRANTYIt is the intent of Jensen Technologies to provide the most reliable data possible for contracted analyses. These services are provided without warranty or liability, implied or otherwise, of any kind.

7

Page 8: OCR Document - Jensen Technologies LLCjensentechnologiesllc.com/Files/TorchAssayingBrochure12... · Web view" or ash, which joins the molten borax glass as a slag, for disposal. The

8

Page 9: OCR Document - Jensen Technologies LLCjensentechnologiesllc.com/Files/TorchAssayingBrochure12... · Web view" or ash, which joins the molten borax glass as a slag, for disposal. The

Jensen Technologies, LLC

15985 South Golden Road, Unit H, Golden, CO 80401Cell: 303-478-3929 E-mail: [email protected]: www.jensentechnologiesllc.com

Sample Submission and Authorization Form Page __of __Please include this form with samples (please print)Company Information (or Attach a Business Card)Company name: ______________________________________ Address: ____________________________________________ Telephone: _______________ Fax: _______________________E-mail:________________________Report To: __________________________________________Report: via: e-mail / Fax / Mail (Circle)Project No: ___________________Project Name: ________________________________________PO No: ________________________Date Results Required: ____________________Disposition of Samples after Analysis: Discard __ Return __ Forward __

WORK REQUEST Cost:

Sample ID Sample Type

Sample Description Analytes Comments

Number of Samples: ___________ (on this page) Date Received: Sample Type: R=Rock; CR=Core; W=Wastewater - WaterPW=Produced Water; S=Soil; PPT=Precipitate; CONC=Concentrate; PERM=Permeate; SL=Sludge; SED=Sediment; O=Other (Specify)SPECIAL INSTRUCTIONS: _______________________________________________________________________________________________________________________________________________________________________________________

Authorization Signature: _______________________________Date: ______________

Payment for services must accompany order unless credit is arranged.

9

Page 10: OCR Document - Jensen Technologies LLCjensentechnologiesllc.com/Files/TorchAssayingBrochure12... · Web view" or ash, which joins the molten borax glass as a slag, for disposal. The

10