Top Banner
GENERAL ARCHITECTURE OF OCB-283 SUBSYSTEMS & FUNCTIONS OF OCB-283
34
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: OCB

GENERAL ARCHITECTURE OF OCB-283

SUBSYSTEMS & FUNCTIONS OF OCB-283

Page 2: OCB

GENERAL FUNCTIONAL BREAKDOWN OF ALCATEL 1000

E-10 (OCB-283)

SUBSCRIBER ACCESSSYSTEM

CONNECTIONAND

CONTROL

OPERATIONAND

MAINTENANCE

CCITT #7SIGNALLING

NETWORK

TELEPHONE NETWORK

DATANETWORK

VALUEADDED NETWORK

O&MNETWORK

DISK

MAGTAPEPABX

Page 3: OCB

OCB-283 ARCHITECTUREOCB-283 COMPRISES OF FOLLOWING 3

SUBSYSTEMS

SUBSCRIBER ACCESSSYSTEM

CONNECTIONAND

CONTROL

OPERATIONAND

MAINTENANCE

CCITT #7SIGNALLING

NETWORK

TELEPHONE NETWORK

DATANETWORK

VALUEADDED NETWORK

O&MNETWORK

DISK

MAGTAPEPABX

• SUBSCRIBER ACCESS SUBSYSTEM

• CONTROL & CONNECTION SUBSYTEM

• OPERATION & MAINTENANCE SUBSYTEM

Page 4: OCB

• Exchange has got 3 basic subsystems :-

•1 SUBSCRIBER ACCESS SUBSYSTEM

•2 CONNECTION & CONTROL SUBSYSTEM

•3. OPERATION & MAINTENANCE SUBSYSTEM

INTRODUCTION OF OCB-283

Page 5: OCB

1. Subscriber Access Subsystem:-

•This is treated as an independent entity

•Every Subscriber Connecting Equipment Rack has got its Signalling Point Number to operate in Common Channel Signalling mode with rest of the exchange Subsystems.

INTRODUCTION OF OCB-283

Page 6: OCB

2. Control & Connection Subsystem is the block consisting of

• A-CONTROL FUNCTIONS

• B-CONNECTION & SWITCHING EQUIPMENTS

INTRODUCTION OF OCB-283

Page 7: OCB

INTRODUCTION OF OCB-283

• A-CONTROL FUNCTIONS

–COMPRISE OF COMMON CONTROL equipments which;

–process

–monitor

–& control the call setup & release

Page 8: OCB

CONTROL SUBSYSTEM

• CONTROL SUBSYSTEM SUPPORTS ALL THE COMOMN CONTROL FUNCTIONS OF EXCHANGE WHICH SETUP & RELEASE A CALL

• COMMON CONTROL FUNCTIONS ARE :- MR,TR,TX,MQ,GX & PC

• IN SOFTWARE FORM THEY ARE CALLED LOGICAL MACHINES

• HARDWARE COMPONENT IS CALLED

MAIN CONTROL STATION SMC• ANY ONE OR MANY CONTROL FUNTIONS CAN

BE LOADED IN A HARDWARE STATION.

Page 9: OCB

ROLE OF COMMON CONTROL FUNCTIONS

• THE MAIN CONTROL STATION SMC SUPPORTS THE FOLLOWING COMMOMN CONTROL FUNCTIONS FOR DOING THE DEFINED JOBS

- MR CALL HANDLER(OVERALL CONTROLLER OF CALLSETUP & RELASE)

- TR TRANSLATOR (DIGIT ANALYSIS & DATA )

- TX CHARGING DEVICE ( TAXING & METERS)

- MQMESSAGE DISTRIBUTOR (MARKING)

- GXMATRIX SYSTEM HANDLER (SWITCHING)

- PC CCS 7 SIGNALLING LINKS NETWORK CONTROLLER (MONITORING OF PUPE)

Page 10: OCB

3. OPERATION & MAINTENANACE SUBSYTEM :-

FOR O&M OF EXCHANGE BY OPERATORS

INTRODUCTION OF OCB-283

Page 11: OCB

LET US NOW UNDERSATAND

COMMON CHANNEL SIGNALLING

BEFORE GOING FURTHER

Page 12: OCB

EXCHANGEA

EXCHANGEEXCHANGECC

EXCHANGEEXCHANGEBB

COMMON SIGNALLING CHANNELCOMMON SIGNALLING CHANNEL

VOICE CHANNELSVOICE CHANNELS

OCB-283 FOLLOWS CCITT-NO 7 SIG.PROTOCOL FOR OCB-283 FOLLOWS CCITT-NO 7 SIG.PROTOCOL FOR

COMMON CHANNEL SIGNALLINGCOMMON CHANNEL SIGNALLING

SIGNALLING TIME SLOT LINK CARRIES ALL THE SIGNALLING SIGNALLING TIME SLOT LINK CARRIES ALL THE SIGNALLING FOR ALL THE VOICE CHANNELS BETWEEN TWO EXCHANGESFOR ALL THE VOICE CHANNELS BETWEEN TWO EXCHANGES

Page 13: OCB

functional

architecture of ocb-283

Page 14: OCB

OM MQ GX MR TX TR PC

COMETA

PUPE

SMTURM

MCX

CSNL

CKTS

LR (4MB / S) DT

LR

LR

COMMUNICATION MULTIPLEXTMN

2 MB/SPCM

CSNDBT

OCB-283 FUNCTIONALDIAGRAM

SMA

SMX

Page 15: OCB

OM MQ GX MR TX TR PC

COMETA

PUPE

SMTURM

MCX

CSNL

CKTS

LR (4MB / S) DT

LR

LR

COMMUNICATION MULTIPLEXTMN

2 MB/SPCM

CSNDBT

SMA

SMX

SUBSCRIBER ACCESS SUBSYSTEM

Page 16: OCB

OM MQ GX MR TX TR PC

COMETA

PUPE

SMTURM

MCX

CSNL

CKTS

LR (4MB / S) DT

LR

LR

COMMUNICATION MULTIPLEXTMN

2 MB/SPCM

CSNDBT

SMA

SMX

CONNECTIONSUBSYSTEM

Page 17: OCB

COMMUNICATION MULTIPLEX

OM MQ GX MR TX TR PC

COMETA

PUPE

SMTURM

MCX

CSNL

CKTS

LR (4MB / S) DT

LR

LR

TMN

2 MB/SPCM

CSNDBT

OCB-283 FUNCTIONALDIAGRAM

SMA

SMX

CONTROLSUBSYSTEM

Page 18: OCB

OM MQ GX MR TX TR PC

COMETA

PUPE

SMTURM

MCX

CSNL

CKTS

LR (4MB / S) DT

LR

LR

COMMUNICATION MULTIPLEXTMN

2 MB/SPCM

CSNDBT

OCB-283 FUNCTIONALDIAGRAM

SMA

SMX

O & M SUBSYSTEM

Page 19: OCB

IN OCB-283

Page 20: OCB

CKTS

FUNCTIONAL EQUIPMENTS INVOLVED IN CALL HANDLING

CALL PROCESSING

OM

TR MR MQ GX PC

ETA

TX

MAS

MIS

SC SC

SC

MCX

COM

CSNL

CSND

CSNL

VC VC

SC

URM

PU/PE

SC: Signalling channelVC: Voice channel

Page 21: OCB

• TS-16 OF LR 0 &LR 1 OF CSN ARE SIGNALLING CHANNELS SC SC BETN. CSN & THE EXCHANGE EQUIPMENT (PU/PE)

CALL PROCESSINGNEW CALL ORIGINATION

CKTS

OM

TR MR MQ GX PCTX

MAS

MIS

SC SC

SC

MCX

COM

CSNL

CSND

CSNL

VC VC

SC

URM

ETA

SC: Signalling channelVC: Voice channel

‘A’ ‘B’

PU/PE

Page 22: OCB

• TS-16 OF LR 0 &LR 1 OF CSN ARE SIGNALLING CHANNELS SC SC BETN. CSN & THE EXCHANGE EQUIPMENT (PU/PE)

• NEW CALL MESSAGE COMES ON SIG.CHANNEL SC

CALL PROCESSINGNEW CALL ORIGINATION

CKTS

OM

TR MR MQ GX PCTX

MAS

MIS

SC SC

SC

MCX

COM

CSNL

CSND

CSNL

VC VC

SC

URM

ETA

SC: Signalling channelVC: Voice channel

‘A’ ‘B’

PU/PE

Page 23: OCB

• NEW CALL MESSAGE IS SENT TO MR BY PUPE.

CALL PROCESSINGCALLING SUBS. COS IDENTIFICATION

CKTS

OM

TR MR MQ GX PCTX

MAS

MIS

SC SC

SC

MCX

COM

CSNL

CSND

CSNL

VC VC

SC

URM

ETA

SC: Signalling channelVC: Voice channel

‘A’ ‘B’

PU/PE

Page 24: OCB

• NEW CALL MESSAGE IS SENT TO MR BY PUPE.• MR REQUESTS CALLING SUBSCRIBER DATA FROM TR ..OVER

MIS• TR PROVIDES CALLING SUB’S COS DATA TO MR

CALL PROCESSINGCALLING SUBS. COS IDENTIFICATION

CKTS

OM

TR MR MQ GX PCTX

MAS

MIS

SC SC

SC

MCX

COM

CSNL

CSND

CSNL

VC VC

SC

URM

ETA

SC: Signalling channelVC: Voice channel

‘A’ ‘B’

PU/PE

Page 25: OCB

• MR REQUESTS MQ TO PROVIDE ADDRESS OF VC ON MCX (LR-LRX CORRESPONDENCE)

• MQ PROVIDES MCX SIDE ADDRESS TO MR

CALL PROCESSINGMCX SIDE ADDRESS OF VC

CKTS

OM

TR MR MQ GX PCTX

MAS

MIS

SC SC

SC

MCX

COM

CSNL

CSND

CSNL

VC VC

SC

URM

ETA

SC: Signalling channelVC: Voice channel

‘A’ ‘B’

PU/PE

Page 26: OCB

CALL PROCESSING

• MR ORDERS MCX FOR CONNECTING DIAL TONE TO CALLING SUBS. ON LRS-TS VC

• DIAL TONE IS PROVIDED FROM MCX (DIALTONE GIVEN BY ETA’s TS-LRE TO MCX)

DIAL TONE PROVISION TO CALLING SUBS.

CKTS

OM

TR MR MQ GX PC

ETA

TX

MAS

MIS

SC SC

SC

MCX

COM

CSNL

CSND

CSNL

VC DT

SC

URM

SC: Signalling channelVC: Voice channel

‘A’ ‘B’

PU/PE

Page 27: OCB

CALL PROCESSING

• FIRST DIGIT IS RECEIVED VIA VOICE CHANNEL VC IN RGF OF ETA (FOR DTMF SUBS.)

RECEPTION OF FIRST DIGIT

CKTS

OM

TR MR MQ GX PC

ETA

TX

MAS

MIS

SC SC

SC

MCX

COM

CSNL

CSND

CSNL

VC

RGF

SC

URM

SC: Signalling channelVC: Voice channel

‘A’ ‘B’

PU/PE

Page 28: OCB

CALL PROCESSING

• FIRST DIGIT IS RECEIVED VIA VOICE CHANNEL VC IN RGF OF ETA (FOR DTMF SUBS.)

• ETA SENDS IT TO MR ON MAS• DIAL TONE IS CUT OFF ON ORDERS OF MR

RECEPTION OF FIRST DIGIT

CKTS

OM

TR MR MQ GX PC

ETA

TX

MAS

MIS

SC SC

SC

MCX

COM

CSNL

CSND

CSNL

VC

RGF

SC

URM

SC: Signalling channelVC: Voice channel

‘A’ ‘B’

PU/PE

Page 29: OCB

CALL PROCESSING

• FIRST FEW DIGITS ARE PRE-ANALYSED ON REQUEST OF MR BY TR

• REMAINING DIGITS MAY BE STILL BEING RECEIVED

DIGIT ANALYSIS

CKTS

OM

TR MR MQ GX PCTX

MAS

MIS

SC SC

SC

MCX

COM

CSNL

CSND

CSNL

VC

RGF

SC

URM

SC: Signalling channelVC: Voice channel

‘A’ ‘B’

PU/PE

Page 30: OCB

CALL PROCESSING• ANALYSIS OF DIGITS COMPLETED CALLED PARTY COS OBTAINED

ROUTING OF CALL -• MR ORDERS CSN-B TO TEST ‘B’ & GIVE VC FOR ‘B’• CSN-B TESTS ‘B’ AND GIVES RINGING TO ‘B’ • MCX GIVES RBT TO ‘A’

SELECTION

‘A’ ‘B’

CKTS

OM

TR MR MQ GX PC

A B

TX

MAS

MIS

SC SC

SC

MCX

COM

CSNL

CSND

CSNL

VC

RGF

SC

URM

SC: Signalling channelVC: Voice channel

PU/PE

Page 31: OCB

CALL PROCESSING• CALLED PARTY B GOES OFF HOOK• CALLED PARTY’S CSN SENDS LOOP CONDITION & VC-B

INFORMATION TO MR OVER SC VIA PUPE• RINGING CURRENT & RBT ARE STOPPED

CALLED PARTY ANSWERS

‘A’ ‘B’

CKTS

OM

TR MR MQ GX PCTX

MAS

MIS

SC SC

SC

MCX

COM

CSNL

CSND

CSNL

VC-A

RGF

SC

URM

SC: Signalling channelVC: Voice channel

PU/PE

VC-B

Page 32: OCB

‘A’ ‘B

CKTS

OM

TR MR MQ GX PCTX

MAS

MIS

SC SC

SC

MCX

COM

CSNL

CSND

CSNL

VC-A

RGF

SC

URM

SC: Signalling channelVC: Voice channel

PU/PE

CALL PROCESSING

• TWO UNIDIRECTIONAL CONNECTIONS ARE ESTABLISHED IN MCX ON ORDER OF MR VIA GX BETWEEN VC-A & VC-B

• ‘A’ & ‘ B ‘ CAN NOW CONVERSE

BOTHWAY CONNECTION

VC-B

Page 33: OCB

‘A’ ‘B

CKTS

OM

TR MR MQ GX PCTX

MAS

MIS

SC SC

SC

MCX

COM

CSNL

CSND

CSNL

VC-A

RGF

SC

URM

SC: Signalling channelVC: Voice channel

PU/PE

CALL PROCESSING

• TWO UNIDIRECTIONAL CONNECTIONS ARE ESTABLISHED IN MCX ON ORDER OF MR VIA GX

• ‘A’ & ‘ B ‘ CAN NOW CONVERSE• CHARGING IS STARTED BY TX - MR RELEASED

CHARGING (METERING)

VC-B

Page 34: OCB

OCB-283EXCH

AND YOUR METER

IS RUNNINGHERE!!!