Cerrar SIS Pantalla anterior Producto: NO SE HA ESCOGIDO NINGUN EQUIPO Modelo: NO SE HA ESCOGIDO NINGUN EQUIPO Configuración: NO SE HA ESCOGIDO NINGUN EQUIPO Pautas de control de contaminación Obtaining Oil Sample for Analysis{1302, 1348, 3030, 3080, 3278, 4011, 4070, 5050, 5056, 5095, 7542} Número de medio -SEBF8482-04 Fecha de publicación -24/03/2009 Fecha de actualización -24/03/2009 i03547304 Obtaining Oil Sample for Analysis{1302, 1348, 3030, 3080, 3278, 4011, 4070, 5050, 5056, 5095, 7542} SMCS - 1302; 1348; 3030; 3080; 3278; 4011; 4070; 5050; 5056; 5095; 7542 Agricultural Tractor: All Articulated Truck: All Asphalt Paver: All Backhoe Loader: All Challenger: All Cold Planer: All Combine: All Compact Track Loader: All Compact Wheel Loader: ALL Earthmoving Compactor: All Excavator: All All Wheeled Excavators Forest Products: All Integrated Toolcarrier: All Landfill Compactor: All Load Haul Dump: All Mini Hydraulic Excavator: All Motor Grader: All Multi Terrain Loader: All Off-Highway Truck/Tractor: All Paving Compactor: All Pipelayer: All Road Reclaimer/Soil Stabilizer: All Skid Steer Loader: All Soil Compactor: All Telehandler: All Track Feller Buncher: Caterpillar Track-Type Loader: All Track-Type Skidder: All Page 1 of 27 Búsqueda del medio - SEBF8482 - Obtaining Oil Sample for Analysis{1302, 1348, 3030,... 27/04/2012 https://sis.cat.com/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisw...
27
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: Obtencion de Muestras de Aceite Cat

Cerrar SIS

Pantalla anterior

Producto: NO SE HA ESCOGIDO NINGUN EQUIPO Modelo: NO SE HA ESCOGIDO NINGUN EQUIPO Configuración: NO SE HA ESCOGIDO NINGUN EQUIPO

Pautas de control de contaminación Obtaining Oil Sample for Analysis{1302, 1348, 3030, 3080, 3278, 4011, 4070, 5050, 5056, 5095, 7542} Número de medio -SEBF8482-04 Fecha de publicación -24/03/2009 Fecha de actualización -24/03/2009

i03547304

Obtaining Oil Sample for Analysis{1302, 1348, 3030, 3080, 3278, 4011, 4070, 5050, 5056, 5095, 7542}SMCS - 1302; 1348; 3030; 3080; 3278; 4011; 4070; 5050; 5056; 5095; 7542 Agricultural Tractor: All Articulated Truck: All Asphalt Paver: All Backhoe Loader: All Challenger: All Cold Planer: All Combine: All Compact Track Loader: All Compact Wheel Loader: ALL Earthmoving Compactor: All Excavator: All All Wheeled Excavators Forest Products: All Integrated Toolcarrier: All Landfill Compactor: All Load Haul Dump: All Mini Hydraulic Excavator: All Motor Grader: All Multi Terrain Loader: All Off-Highway Truck/Tractor: All Paving Compactor: All Pipelayer: All Road Reclaimer/Soil Stabilizer: All Skid Steer Loader: All Soil Compactor: All Telehandler: All Track Feller Buncher: Caterpillar Track-Type Loader: All Track-Type Skidder: All

Page 1 of 27Búsqueda del medio - SEBF8482 - Obtaining Oil Sample for Analysis{1302, 1348, 3030,...

27/04/2012https://sis.cat.com/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisw...

Page 2: Obtencion de Muestras de Aceite Cat

Track-Type Tractor: All Underground Articulated Truck: All Wheel Dozer: All Wheel Feller Buncher: All Wheel Loader: All Wheel Skidder: All Wheel Tractor-Scraper: All

IntroductionThis Guideline enables dealers and the dealer's customers to benefit from cost reductions which were made possible through an established Contamination Control Program. Fluids that are used in Caterpillar machines are highly effective unless the fluid contains damaging amounts of contaminates. Therefore, every effort must be made in order to reduce the contamination level within Caterpillar fluid systems. Caterpillar makes ongoing changes and improvements to the Caterpillar products. This guideline must be used with the latest technical information available from Caterpillar in order to ensure that such changes and improvements are incorporated when applicable.For questions or additional information concerning this guideline, submit a feedback form in the Service Information System website. In order to address an urgent need, please use the following to relay your request to Caterpillar Repair Process Engineering:

Cat Dealer Technical Communicator•Dealer Solution Network•Cat Technical Representative•Knowledge Network (on-line)•

If a Contatmincation Control Guideline is required, but not available in SIS Web, submit a feedback form in the Service Information System website.

SummaryA good oil sample that accurately represents the condition of the fluid system is vital for the success of any analysis program. For this reason, the oil should be at the system operating temperature or at least 50 °C (120 °F) if the normal operating temperature cannot be reached when the sample is taken. The following guideline describes the methods in order to obtain oil samples from machine fluid systems. Bottle sampling (pressure and suction) and portable particle counter methods are included in this guideline. These processes are used when an oil sample is taken or when an on-line particle count is taken on any fluid system (such as hydraulic, steering, power train, engine and final drive).

References

References Table 1

Page 2 of 27Búsqueda del medio - SEBF8482 - Obtaining Oil Sample for Analysis{1302, 1348, 3030,...

27/04/2012https://sis.cat.com/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisw...

Page 3: Obtencion de Muestras de Aceite Cat

Media Number Title

SEHS9043 Valve Installation for Scheduled Oil Sampling of Engine, Transmission, Hydraulics, and Steering

PEVN4831 Count on Caterpillar Particle Analyzers NEHS0799 Tool Operating Manual for S40 Portable Particle Analyzer PEEP5031 Oil Analysis Bottle Label

NOTICE

Keep all parts clean and keep all parts free of contamination.

Hot oil and hot components can cause personal injury. Do not allow hot oil or hot components to contact the skin.

On-line Particle Counting using S·O·S Valves

Parts List Quantity Part Number Parts Description 1 162-5791 Shop Towel 1 170-8500 S40 Particle Counter 1 210-5530 Quick Disconnect 1 (1) GE06L1/4NP TA3C Male Connector 1 188-0639 Hose as Replacement Parts

Table 2

( 1 ) These items can be obtained by contacting Caterpillar Capital Tooling Group. A proper fitting will be provided at no cost.

Page 3 of 27Búsqueda del medio - SEBF8482 - Obtaining Oil Sample for Analysis{1302, 1348, 3030,...

27/04/2012https://sis.cat.com/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisw...

Page 4: Obtencion de Muestras de Aceite Cat

Illustration 1 g01281548

170-8500 Pama On-line Particle Counter

Note: Refer to Contamination Control Guideline, PEVN4831, "Count on Caterpillar Particle Analyzers" and refer to Tool Operating Manual, NEHS0799, "Manual for S40 Portable Particle Analyzer" for proper installation and operation. Caterpillar recommends to connected the on-line particle counters directly to the S·O·S valve.Note: Refer to the Operation and Maintenance Manual for the S·O·S valve locations. Refer to the Test and Adjust Manual in order to obtain the system pressures. Prepare all equipment used to sample oil in advance in order to prevent contamination prior to taking a sample.

Illustration 2 g01281550

Left - high pressure hose, Right - low pressure hose

Determine the fluid system pressure at the location where the sample is to be taken (S·O·S valve). For proper supply hose and hardware refer to Contamination Control Guideline, PEVN4831, "Count on Caterpillar Particle Analyzers" and refer to Tool Operating Manual, NEHS0799, "Tool Operating Manual for S40 Portable Particle Analyzer".

1.

Page 4 of 27Búsqueda del medio - SEBF8482 - Obtaining Oil Sample for Analysis{1302, 1348, 3030,...

27/04/2012https://sis.cat.com/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisw...

Page 5: Obtencion de Muestras de Aceite Cat

Exercise the machine until the sampled fluid system is up to the normal operating temperature or at a minimum of 50 °C (120 °F).

2.

Park the machine on level ground. Lower all of the attachments. Engage the parking brake.3.Set the engine at low idle. All systems must be in a safe position.4.

Illustration 3 g01281551

S·O·S valve dust cover

Remove the dust cover from the S·O·S valve. Refer to the Operating and Maintenance Manual for the S·O·S valve locations.

5.

Page 5 of 27Búsqueda del medio - SEBF8482 - Obtaining Oil Sample for Analysis{1302, 1348, 3030,...

27/04/2012https://sis.cat.com/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisw...

Page 6: Obtencion de Muestras de Aceite Cat

Illustration 4 g01281552

162-5791 Lint Free Towel . Transmission S·O·S valve shown.

Clean the S·O·S valve with a clean 162-5791 Lint Free Towel .6.

Illustration 5 g01281553

210-5530 Quick Disconnect

Make sure that the 210-5530 Quick Disconnect is clean.7.

Illustration 6 g01281554

Page 6 of 27Búsqueda del medio - SEBF8482 - Obtaining Oil Sample for Analysis{1302, 1348, 3030,...

27/04/2012https://sis.cat.com/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisw...

Page 7: Obtencion de Muestras de Aceite Cat

Typical particle counter supply hose attached to the S·O·S valve (low pressure hose shown)

Attach the particle counter supply hose to the S·O·S valve.8.

Illustration 7 g01281555

Particle counter connections

Secure the particle counter's discharge hose with a catch basin.9.If the sampled fluid system has cooled down, exercise the machine until the sampled fluid system is up to normal operating temperature or a minimum of 50 °C (120 °F).

10.

NOTICE

Do not move the machine while the particle counter in connected. Moving the machine in this condition could cause damage to the

machine and/or the particle counter.

Note: Allow power train circuits to idle for a minimum of ten minutes prior to particle counting. This will allow entrapped air to escape from the sampled oil. Air trapped in the oil will distort the particle counter readings.Operate the particle counter according to the manufacturer's instructions in order to obtain an oil sample reading.

11.

Page 7 of 27Búsqueda del medio - SEBF8482 - Obtaining Oil Sample for Analysis{1302, 1348, 3030,...

27/04/2012https://sis.cat.com/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisw...

Page 8: Obtencion de Muestras de Aceite Cat

Illustration 8 g01281556

Remove sampling hoses.

After testing, disconnect the particle counter hose assembly from the machine. After testing, disconnect the hose assembly from the particle counter. Drain the hoses. Cap all the hose ends. Store the particle counter and store the hoses in a clean location.

12.

Illustration 9 g01281557

Replace dust cap

Page 8 of 27Búsqueda del medio - SEBF8482 - Obtaining Oil Sample for Analysis{1302, 1348, 3030,...

27/04/2012https://sis.cat.com/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisw...

Page 9: Obtencion de Muestras de Aceite Cat

Install the dust cap onto the S·O·S valve. Make sure that the cap is clean on the inside.13.Properly dispose of any waste oil.14.

Bottle Sampling Using Oil Valve Probe and S·O·S Valve

Parts List Quantity Part Number Part Description

1 162-5791 Shop Towel 2 169-8373 Sample Bottle Group 1 162-8873 Sample Bottle Probe Holder 1 8T-9208 Probe Assembly (1) 1 4C-4600 Sample Bottle Shipping Container

Table 3

( 1 ) Purging with tube

Hot oil and hot components can cause personal injury. Do not allow hot oil or hot components to contact the skin.

Note: Refer to Operation and Maintenance Manual for the S·O·S valve locations. Refer to the Test and Adjust Manual in order to obtain the system pressure. Only perform a bottle sample when the system pressures are below 3450 kPa (500 psi). Prepare all equipment used to sample oil and protect the equipment from contamination.

Page 9 of 27Búsqueda del medio - SEBF8482 - Obtaining Oil Sample for Analysis{1302, 1348, 3030,...

27/04/2012https://sis.cat.com/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisw...

Page 10: Obtencion de Muestras de Aceite Cat

Illustration 10 g01281558

S·O·S mailing label

Fill out the S·O·S label. Pay special attention to the serial number, sample data, service meter units on the equipment, service meter units on the oil, oil type, oil brand and the amount of oil added. Indicate if the oil was changed after the sample was taken.

1.

Illustration 11 g01281559

Sample bottle package

Open the 169-8373 Sample Bottle package. Remove the sampling probe tube from the bag.2.

Page 10 of 27Búsqueda del medio - SEBF8482 - Obtaining Oil Sample for Analysis{1302, 1348, 30...

27/04/2012https://sis.cat.com/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisw...

Page 11: Obtencion de Muestras de Aceite Cat

Illustration 12 g01281560

Probe holder and probe

Insert the open sampling probe tube into and through the 162-8873 Sample Bottle Probe Holder counter bored end. Pull the probe tube all the way through the holder until the sampling needle seats in the holder.

3.

Illustration 13 g01281561

Remove the sampling bottle from the package. Install the cap with two holes onto the bottle. Install the probe tube into one of the holes in the cap.

4.

Page 11 of 27Búsqueda del medio - SEBF8482 - Obtaining Oil Sample for Analysis{1302, 1348, 30...

27/04/2012https://sis.cat.com/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisw...

Page 12: Obtencion de Muestras de Aceite Cat

Illustration 14 g01281562

Return the assembled bottle and return the probe back into the package in order to prevent contamination.

5.

Exercise the machine until the system oil to be sampled is up to normal operating temperature or at a minimum of 50 °C (120 °F).

6.

Park the machine on level ground. Lower all the attachments. Engage the parking brake.7.Set the engine at low idle. Make sure that all systems are in safe positions. Refer to the Operation and Maintenance Manual.

8.

Illustration 15 g01281564

Remove the dust cover from the S·O·S valve.9.

Page 12 of 27Búsqueda del medio - SEBF8482 - Obtaining Oil Sample for Analysis{1302, 1348, 30...

27/04/2012https://sis.cat.com/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisw...

Page 13: Obtencion de Muestras de Aceite Cat

Illustration 16 g01281565

Clean the S·O·S valve with a clean 162-5791 Lint Free Shop Towel .10.

Illustration 17 g01281566

Purging S·O·S valve with 8T-9208 Purge Probe and tube

Purge the S·O·S valve by pressing the 8T-9208 Purge Probe onto the S·O·S valve. Purge a minimum of one sample bottle of oil or more if it is required to ensure that all the dead volume of the fluid is purged and the sampling nipple is internally cleaned.

11.

Note: If the oil flow is slow at low idle, it may be necessary to have someone accelerate the engine.

Page 13 of 27Búsqueda del medio - SEBF8482 - Obtaining Oil Sample for Analysis{1302, 1348, 30...

27/04/2012https://sis.cat.com/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisw...

Page 14: Obtencion de Muestras de Aceite Cat

Illustration 18 g01281567

Oil disposal

Properly dispose of the purged oil.12.

Illustration 19 g01281568

Prepared bottle sample

Page 14 of 27Búsqueda del medio - SEBF8482 - Obtaining Oil Sample for Analysis{1302, 1348, 30...

27/04/2012https://sis.cat.com/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisw...

Page 15: Obtencion de Muestras de Aceite Cat

Remove the prepared sample bottle from the package.13.

Illustration 20 g01281576

Flush sample bottle

Rinse the sample bottle and rinse the probe tube with the system oil. Rinse the bottle by filling the bottle half full with the system oil.

14.

Illustration 21 g01281577

Flush sample bottle

Page 15 of 27Búsqueda del medio - SEBF8482 - Obtaining Oil Sample for Analysis{1302, 1348, 30...

27/04/2012https://sis.cat.com/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisw...

Page 16: Obtencion de Muestras de Aceite Cat

Shake the sample bottle vigorously for several seconds.15.

Illustration 22 g01281578

Then empty the oil into a waste oil container.16.

Illustration 23 g01281579

Page 16 of 27Búsqueda del medio - SEBF8482 - Obtaining Oil Sample for Analysis{1302, 1348, 30...

27/04/2012https://sis.cat.com/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisw...

Page 17: Obtencion de Muestras de Aceite Cat

Fill the sample bottle to the "fill range" imprinted on the bottle, but do not fill beyond the fill mark.

17.

Note: Do not fill the bottle beyond the fill mark. Filling beyond the fill mark will not allow for proper lab mixing.

Illustration 24 g01281580

Remove the sampling probe tube from the bottle lid. Save the knurled probe holder and discard the probe tube.

18.

Illustration 25 g01281581

Immediately replace the two-hole lid on the sample bottle with the solid lid (no hole). Dispose of the lid with two holes.

19.

Page 17 of 27Búsqueda del medio - SEBF8482 - Obtaining Oil Sample for Analysis{1302, 1348, 30...

27/04/2012https://sis.cat.com/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisw...

Page 18: Obtencion de Muestras de Aceite Cat

Illustration 26 g01281583

If it is necessary, clean the outside of the bottle.20.

Illustration 27 g01281585

Mailing tube with completed label

Place the bottle with the completed information label into a 4C-4600 Shipping Container or take the bottle and label to the lab.

21.

Page 18 of 27Búsqueda del medio - SEBF8482 - Obtaining Oil Sample for Analysis{1302, 1348, 30...

27/04/2012https://sis.cat.com/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisw...

Page 19: Obtencion de Muestras de Aceite Cat

Illustration 28 g01281586

Wipe any oil off the sample valve.22.

Illustration 29 g01281588

Install the dust cap onto the S·O·S valve and check that the cap is clean on the inside.23.

Zero Pressure System Using a Hand Vacuum Pump

Page 19 of 27Búsqueda del medio - SEBF8482 - Obtaining Oil Sample for Analysis{1302, 1348, 30...

27/04/2012https://sis.cat.com/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisw...

Page 20: Obtencion de Muestras de Aceite Cat

Parts List Quantity Part Number Part Description 1 162-5791 Shop Towel 2 169-8373 Sample Bottle Group 1 1U-5718 Oil Sampling Vacuum Pump 1 4C-4600 Sample Bottle Shipping Container 1 1U-7648 Tube Cutter 1U-8757 Tube

Table 4

Hot oil and hot components can cause personal injury. Do not allow hot oil or hot components to contact the skin.

Note: Typical nonpressurized systems are reservoirs, differentials, final drives, or return lines (drains). The sample location should be near the middle of the reservoir's fluid level and away from the sidewall. The sample location should be where the fluid is normally in motion, thoroughly mixed, and at normal operating temperature. The sample should be taken as soon as possible after the machine exercising has been stopped. Prepare all sampling hardware before an oil sample is taken.Note: Never use the same vacuum pump for obtaining both oil and coolant samples. Although the fluid does not enter the barrel of the pump, a small residue of glycol from the coolant remains in the pump and can contaminate the oil sample. This will indicate a "false positive" coolant leak in the oil system being sampled.

Page 20 of 27Búsqueda del medio - SEBF8482 - Obtaining Oil Sample for Analysis{1302, 1348, 30...

27/04/2012https://sis.cat.com/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisw...

Page 21: Obtencion de Muestras de Aceite Cat

Illustration 30 g01281590

Fill out the S·O·S label. Pay special attention to the serial number, sample data, service meter units on equipment, service meter units on oil, oil type, oil brand and the amount of oil added. Indicate if the oil was changed after the sample was taken.

1.

Illustration 31 g01281591

1U-8757 Tube cut to length

Measure the tubing and then cut new 1U-8757 Tubing to the length of the dipstick. If there is no dipstick, cut the tubing so that the tubing reaches about halfway into the oil depth of the compartment being sampled.

2.

Note: Use a 1U-8757 Tube Cutter in order to prevent the tubing from being contaminated.

Illustration 32 g01281593

Page 21 of 27Búsqueda del medio - SEBF8482 - Obtaining Oil Sample for Analysis{1302, 1348, 30...

27/04/2012https://sis.cat.com/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisw...

Page 22: Obtencion de Muestras de Aceite Cat

Install tubing into the 1U-5718 Vacuum Pump . The bottle end of the tubing should be approximately 25.4 mm (1 inch) beyond the base of the vacuum pump head.

3.

Illustration 33 g01281594

Install a new bottle to be sampled to the vacuum pump.4.

Illustration 34 g01281595

Store the vacuum pump assembly and store the clean bottle cap in the plastic bag until the parts are ready for use.

5.

Exercise the machine fluid to be sampled until the fluid system is up to normal operating temperature. If normal operating temperature cannot be reached, then 50 °C (120 °F) is acceptable.

6.

Park the machine on level ground. Lower all the attachments. Engage the parking brake.7.Shut the machine off. Make sure that all the systems are in safe positions. Refer to the Operation and Maintenance Manual.

8.

Page 22 of 27Búsqueda del medio - SEBF8482 - Obtaining Oil Sample for Analysis{1302, 1348, 30...

27/04/2012https://sis.cat.com/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisw...

Page 23: Obtencion de Muestras de Aceite Cat

Illustration 35 g01281596

Clean the sample location using a clean 162-5791 Lint Free Shop Towel .9.

Illustration 36 g01281597

Keep the sample bottle vertical when taking samples. Pump the vacuum pump handle in order to create a vacuum.

10.

Note: If the bottle is tilted, the oil will enter into the suction of the barrel of the vacuum pump. This will cause cross contamination of subsequent samples.

Page 23 of 27Búsqueda del medio - SEBF8482 - Obtaining Oil Sample for Analysis{1302, 1348, 30...

27/04/2012https://sis.cat.com/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisw...

Page 24: Obtencion de Muestras de Aceite Cat

Illustration 37 g01281598

Fill the sample bottle half full with system oil.11.Remove the bottle from the vacuum pump.12.

Illustration 38 g01281577

Install a clean lid and shake the bottle vigorously for several seconds.13.

Page 24 of 27Búsqueda del medio - SEBF8482 - Obtaining Oil Sample for Analysis{1302, 1348, 30...

27/04/2012https://sis.cat.com/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisw...

Page 25: Obtencion de Muestras de Aceite Cat

Illustration 39 g01281578

Empty the bottle into a waste oil container.14.reinstall the sample bottle to the vacuum pump.15.

Illustration 40 g01281599

Take the oil sample in the same manner. Fill the bottle to the "fill range".16.Note: Do not fill the bottle beyond the fill mark. This will not allow for proper lab mixing.

Page 25 of 27Búsqueda del medio - SEBF8482 - Obtaining Oil Sample for Analysis{1302, 1348, 30...

27/04/2012https://sis.cat.com/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisw...

Page 26: Obtencion de Muestras de Aceite Cat

Illustration 41 g01281583

When the oil bottle is filled, remove the bottle from the vacuum pump. Cap the bottle with a clean lid (no holes).

17.

Clean the outside of the bottle.18.

Illustration 42 g01281585

Place the bottle with the completed information label into a 4C-4600 Shipping Container or take the bottle and the label to the lab.

19.

Remove the tubing from the vacuum pump and discard the tubing in the probe location.20.

Page 26 of 27Búsqueda del medio - SEBF8482 - Obtaining Oil Sample for Analysis{1302, 1348, 30...

27/04/2012https://sis.cat.com/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisw...

Page 27: Obtencion de Muestras de Aceite Cat

Illustration 43 g01281596

Clean any covers, caps, plates, etc that have been removed.21.