OVER 25 YEARS OF REINFORCING FIBERS Nycon Corporation 300 Ben Fairless Drive Fairless Hills, PA 19030 www.nycon.com P: 800-456-9266 P: 215-310-2139 F: 215-736-2652 [email protected] NYCON-G
13

NYCON-G · 2019-12-06 · during or after batching of the ingredients and mixed at high speed for a minimum of five minutes. Additional mixing does not adversely affect the distribution

Mar 13, 2020

Download

Documents

dariahiddleston
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: NYCON-G · 2019-12-06 · during or after batching of the ingredients and mixed at high speed for a minimum of five minutes. Additional mixing does not adversely affect the distribution

OVER 25 YEARS OF REINFORCING FIBERS

Nycon Corporation 300 Ben Fairless DriveFairless Hills, PA 19030www.nycon.com

P: 800-456-9266P: 215-310-2139F: 215-736-2652 [email protected]

NYCON-G

Page 2: NYCON-G · 2019-12-06 · during or after batching of the ingredients and mixed at high speed for a minimum of five minutes. Additional mixing does not adversely affect the distribution

OVER 25 YEARS OF REINFORCING FIBERS

ABOUT NYCON®

Nycon pioneered the use of fibers for secondary reinforcement in many products including concrete, asphalt, plastic and soils. A value added manufacturer and supplier, Nycon has a broad portfolio of reinforcing fibers, which include “Green”, nylon, polypropylene, AR glass, steel, macro, high-dosage synthetic fibers, PVA and steel/synthetic blends. All our reinforcing fibers are available in handy “melt-away” water dissolving bags or “toss-in” paper beater bags.

+ = BETTER CONCRETE

NYCON FIBERS CONCRETE

Page 3: NYCON-G · 2019-12-06 · during or after batching of the ingredients and mixed at high speed for a minimum of five minutes. Additional mixing does not adversely affect the distribution

OVER 25 YEARS OF REINFORCING FIBERS

WHAT IS NYCON-G?

NYCON-G is a processed, reclaimed reinforcing fiber that offers plastic shrinkage crack control and superior finish at a dose of

1 pound/cy.

Page 4: NYCON-G · 2019-12-06 · during or after batching of the ingredients and mixed at high speed for a minimum of five minutes. Additional mixing does not adversely affect the distribution

OVER 25 YEARS OF REINFORCING FIBERS

GLOBALLY RESPONSIBLE

NYCON-G fibers are made from 100% reclaimed post-industrial and

post-consumer carpet. For years, little has been done with carpet waste

aside from throwing it away.

Page 5: NYCON-G · 2019-12-06 · during or after batching of the ingredients and mixed at high speed for a minimum of five minutes. Additional mixing does not adversely affect the distribution

OVER 25 YEARS OF REINFORCING FIBERS

GLOBALLY RESPONSIBLENow, thanks to our advanced patented technology (U.S. Patent #6,971,784 and #7,563,017, other US and foreign patents pending), Nycon “harvests” carpet waste much like an agricultural asset. Discarded carpet once taken to landfills is now a resource for producing our proprietary, high-value concrete reinforcing fibers. In addition to conserving landfill space, recycling carpet also saves water

and reduces carbon dioxide emissions that contribute to global warming.

Page 6: NYCON-G · 2019-12-06 · during or after batching of the ingredients and mixed at high speed for a minimum of five minutes. Additional mixing does not adversely affect the distribution

OVER 25 YEARS OF REINFORCING FIBERS

MIXING

NYCON-G can be added to the mixing system during or after batching of the ingredients and mixed at high speed for a minimum of five minutes. Additional mixing does not adversely affect the distribution or overall performance of NYCON-G. The addition of NYCON-G at the normal recommended dosage rate does not require any mix design or application changes. A water reducer or super-plasticizer is recommended in concrete products where

improved workability is desired.

Page 7: NYCON-G · 2019-12-06 · during or after batching of the ingredients and mixed at high speed for a minimum of five minutes. Additional mixing does not adversely affect the distribution

OVER 25 YEARS OF REINFORCING FIBERS

FINISHED LOOK

The Heldrich Hotel & Conference CenterNew Brunswick, NJ

NYCON-G assisted the owner of the Heldrich Hotel in achieving the

highest LEEDS rating for the building while contributing to the overall quality of the

structure. The Heldrich Hotel complex was built using 550 precast architectural

panels that incorporated 3 lb NYCON-G per cy.

Page 8: NYCON-G · 2019-12-06 · during or after batching of the ingredients and mixed at high speed for a minimum of five minutes. Additional mixing does not adversely affect the distribution

OVER 25 YEARS OF REINFORCING FIBERS

• Filament bond with the concrete• Reduces plastic shrinkage cracking• Provides multi-dimensional reinforcement• Improves impact, shatter and abrasion resistance of concrete• Enhances durability and toughness of concrete• Excellent “no fuzz” finishability

NYCON-G BENEFITS

Because NYCON-G blends with the color of the product & doesn’t float to the surface, it’s virtually invisible in concrete.

Page 9: NYCON-G · 2019-12-06 · during or after batching of the ingredients and mixed at high speed for a minimum of five minutes. Additional mixing does not adversely affect the distribution

OVER 25 YEARS OF REINFORCING FIBERS

PRICE STABLE FIBERThe fiber market is constantly changing.

Fluxuations in material cost dictates the price of most reinforcing fibers on the market. However, because Nycon-G is made from reclaimed products, a material with very little cost variation, it is the most price stable fiber on the market.

Page 10: NYCON-G · 2019-12-06 · during or after batching of the ingredients and mixed at high speed for a minimum of five minutes. Additional mixing does not adversely affect the distribution

OVER 25 YEARS OF REINFORCING FIBERS

CONCRETE WITHOUT NYCON-G

CONCRETE WITH NYCON-G

Cracked Not Cracked

PUT TO THE TEST - CRACK CONTROL

Page 11: NYCON-G · 2019-12-06 · during or after batching of the ingredients and mixed at high speed for a minimum of five minutes. Additional mixing does not adversely affect the distribution

OVER 25 YEARS OF REINFORCING FIBERS

NYCON-G

PHYSICAL PROPERTIESFilament Diameter 12 Denier (57 Microns)

Fiber Length Well Graded < 0.75” (19mm)

Specific Gravity 1.10

Tensile Strength 44 ksi (300 MPa)

Flexural Strength 400 ksi (2.8 GPa)

Melting Point 435o F (225o C)

Color Tan

Water Absorption 1% to 3% by Weight

Alkali Resistance High

Concrete Surface Not Fuzzy

Corrosion Resistance High

NYCON-GNylon, Medium Denier, Superior Finish

Page 12: NYCON-G · 2019-12-06 · during or after batching of the ingredients and mixed at high speed for a minimum of five minutes. Additional mixing does not adversely affect the distribution

OVER 25 YEARS OF REINFORCING FIBERS

PACKAGING

SKIDS BOXES

Page 13: NYCON-G · 2019-12-06 · during or after batching of the ingredients and mixed at high speed for a minimum of five minutes. Additional mixing does not adversely affect the distribution

OVER 25 YEARS OF REINFORCING FIBERS

Nycon Corporation 300 Ben Fairless DriveFairless Hills, PA 19030www.nycon.com

P: 800-456-9266P: 215-310-2139F: 215-736-2652 [email protected]

Nycon Corporation provides concrete solutions world-wide. To connect with a specialist in your

area, please call (800) 456-9266 or visit us online at www.nycon.com