Top Banner
1 NU-LEC NU-LEC Loop Automation Reclosers & Sectionalizers Loop Automation Reclosers & Sectionalizers
27

Nulec- Autorecloser

Sep 16, 2015

Download

Documents

Michael Smith

Autorecloser-1
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
  • 1NU-LECNU-LEC

    Loop Automation

    Reclosers & Sectionalizers

    Loop Automation

    Reclosers & Sectionalizers

  • 2NU-LEC LLCNU-LEC LLC

    NU-LEC LLC is a wholly unit of NU-LEC Industries, Pty, Ltd.

    Sales and service center for United States, Canada, and the Caribbean.

    Warehouse and Main Office 1252 Old Alpharetta Rd.

    Alpharetta, GA

  • 3NU-LEC Industries Pty, LtdNU-LEC Industries Pty, Ltd

    Nu-Lec IndustriesCorporate Office andFactory. Brisbane

  • 4Schneider Electric OverviewSchneider Electric Overview

    Major Brands:Square DMerlin GerinModiconTelemecaniqueNu-Lec

    85,000+ employees in 130 countries

    2001 sales revenue: $9 billion

    620 commercial sites and 9000 sales outlets

    3,000+ Engineers and Technicians and development centers in 20 countries.

    1,500+ software engineers engaged in numerous R&D programs.

  • 5NU-LECs Worldwide Distribution NetworkNU-LECs Worldwide Distribution Network

  • 6Electronic ProductsElectronic Products

  • 7NU-LECsNU-LECsDistribution Automation Optimized Family of

    ProductsDistribution Automation Optimized Family of

    Products

  • 8NU-LECNU-LEC

    N SERIES RECLOSERN SERIES RECLOSER

  • 9CIRCUIT BREAKER

    plus

    ELECTRONIC CONTROL

    equals

    AUTO-CIRCUIT RECLOSER

  • 10

    N Series RecloserN Series RecloserArrestor Mounting Bracketsand lifting points. Epoxy Bushings w/ CVTs(Boots Removed)

    Large Open/CloseIndicator Brass Rating Plates

    Natural Matte FinishGrade 316 Stainless Steel

    Mechanical Trip LevelOn This Side

    N SeriesRecloser

    N SeriesRecloser

  • 11

    N Series Recloser FamilyN Series Recloser Family

    Four models:N12-15 rated 15.5kV 630A 110kV 12.5kAN36-27 rated 27kV 630A 150kV 12.5kAN36-12.5 rated 38kV 630A 170kV 12.5kAN36-16 rated 38kV 800A 170kV 16kA

    PTCC control and communications cubicle with integral RTU

    Type Tested to comply with ANSI C37.60,IEC56 & IEC255

  • 12

    N Series Recloser FeaturesN Series Recloser FeaturesFully insulated bushing arrangement

    Grade 316 stainless steel tank (sealed for life). Natural matte finish.

    Vacuum Interrupters (Cutler-Hammer)

    SF6 Gas insulation medium (low psi, low vol.) approx. 5.1 lbs/in2

    Single pole mounting 500 lbs

    LV solenoid close and trip from stored energy charged capacitors.

    No Scheduled Maintenance for 30 years.

    Voltage measurement to a 2.5% accuracy on all six bushings

  • 13

    N Series Recloser DutyN Series Recloser Duty

    10,000 Mechanical Operations

    Breaking Duty Vacuum Interrupter:Rated Load: 10,000 Operations6kA: 1,000 Operations12.5kA:

    N12: 15kV, 100 OperationsN36: 27kV, 520 OperationsN36: 38kV, 520 Operations

  • 14

    Control Cubicle

    Natural Finish Grade 316 Stainless Steel

    Operator Hatch

    Insulated throughout

    Mini-breakers for Aux. power and Batteries

    Operator Panel with 4 line LCDdisplay, computer port and pushbutton controls. Plain English text, no codes.

    Comms. Tray with RS232 cable and DC power supply

    12 volt sealed lead acid cell batteries. 5 day hold up w/o comms. 5 year replacement.

    PTCC ControlCubicle

    PTCC ControlCubicle

    Battery heater (not shown)Temperate model only.

  • 15

    Control Block DiagramControl Block Diagram

    MEMORY

    AUXILIARYSWITCHES

    VACUUM INTERRUPTER

    PRESSURESENSOR

    CVT

    CT

    CVT

    H

    V

    L

    I

    N

    E

    3

    P

    H

    A

    S

    E

    S

    C

    I

    R

    C

    U

    I

    T

    B

    R

    E

    A

    K

    E

    R

    TRIP/CLOSEMOTOR

    RADIO

    MODEM

    REMOTEI/O

    OPERATORSUB SYSTEM

    PANEL

    WSOSOPERATOR

    PC

    TRIPCAPACITOR

    UNINTERRUPTIBLEPOWER SUPPLY

    MOTORPOWERSUPPLY

    ANALOGUE TODIGITAL

    CONVERTER

    ANALOGUE FRONT END

    MODEM

    S

    E

    R

    I

    A

    L

    I

    N

    T

    E

    R

    F

    A

    C

    E

    M

    I

    C

    R

    O

    P

    R

    O

    C

    E

    S

    S

    O

    R

    D

    I

    G

    I

    T

    A

    L

    I

    N

    T

    E

    R

    F

    A

    C

    E

    V23 FSK

    RS232

    SPI

    RS232

    CLOSECAPACITOR

    BATTERY

    C

    A

    P

    M

    C

    O

    N

    T

    R

    O

    L

    C

    U

    B

    I

    C

    L

    E

    C

    O

    N

    T

    R

    O

    L

    C

    U

    B

    I

    C

    L

    E

    E

    N

    T

    R

    Y

    M

    O

    D

    U

    L

    E

    CONTROLCABLE AUXILIARY POWER SUPPLY

  • 16

    Operator Control panel

    ---------- QUICK KEY SELECTION ---------S

    Auto ON/OFF Prot GroupLocal/Remote Enter Reset Flags

  • 17

    MeasurementMeasurement

    Measurement of voltage on all three phases, including sensing of voltage on all six terminals. This is achieved to a 2.5% accuracy by digitizing each bushings ground screen current in real time in the microprocessor.

    Measurement of current on all three phases. (CT ratio 2000:1)

  • 18

    ProtectionProtection

    Over current protectionDirectional Blocking.Live Load blocking.High Current Lockout.Inrush Restraint (Automatic).Cold Load Pickup (Automatic).Sequence Co-ordination.Over/Under Frequency Protection and Restoration.

  • 19

    NU-LECNU-LEC

    RL SERIESLOAD-BREAK SWITCH

    ANDSECTIONALIZER

    RL SERIESLOAD-BREAK SWITCH

    ANDSECTIONALIZER

  • 20

    RL SeriesRL SeriesMounting Support Brackets

    Add on Motor Pack

    Bare Terminals 15kv Only

    Ground Stud

    Hot Stick Operator withLarge Status Indicator

    Natural matte finish, grade 316 stainless steel

    Lifting Handles

    Add SCADA and fully Automate with PTCC Control Cubicle

    Manual Lockout arm

  • 21

    RL SeriesRL Series15-27 kV

    Maximum System Voltage 15-27 kV

    Continuous current 630 A

    Fault Make (RMS) 12.5 kA/16kA

    Fault Make (Peak) 31.5 kA/40kA

    Mechanical Operations 3000

    Rated Full Load Operations 600

  • 22

    InstallationInstallation

    Grounding pointsAll grounding should be of correct size, using crimped connections and be kept as short as practicable to prevent high impedances during impulse.

    Lightning arrestors

    SCADA comms. (optional)

    Control cable

    PTCC Control cubicle (optional)

  • 23

    ProtectionProtectionAuto Change to protection group A and B depending on direction of power flow. User configurable.Protection settings easily loaded from the control panel or WSOS software.

    Special Features

    Loop Automation: Has the ability to isolate a faulted section of feeder within one minute with out the need for peer-to-peer communications.

    Auto-Changeover: Has the ability to quickly change over from a main feedto an alternate feed at a critical load; requires peer-to-peer communications.

  • 24

  • 25

    Adjustable heightgalvanized steel Substation

    Mounting Frame

  • 26

    UtiliNet Radio

  • Auto-Changeover &

    Feeder Automation

    Reclosers & Sectionalizers

    NU-LECNU-LEC LLCNU-LEC Industries Pty, LtdSchneider Electric OverviewNU-LECs Worldwide Distribution NetworkElectronic ProductsNU-LECsDistribution Automation Optimized Family of ProductsNU-LECN Series RecloserN Series Recloser FamilyN Series Recloser FeaturesN Series Recloser DutyControl CubicleControl Block DiagramOperator Control panelMeasurementProtectionNU-LECInstallationProtection