MS Excel (All parameter fields) Generated: Product: LTE BTS Rel/ver: LN1.0/inc18 MO Class Parameter Id Parameter Name Abbreviated Name 3GPP Name Data Type LNBTS 53084 QCI qci Number LNBTS 53104 RRC Guard Timer R rrcGuardTimer Number LNBTS 53115 Handover Cancel L tX2RelocHold Number LNCEL 53259 A3 Offset a3Offset Number LNCEL 53260 A3 Report Amount a3ReportAmount Enumeratio
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
MS Excel (All parameter fields) Generated: Fri Mar 19 18:12:59 EET 2010
Product: LTE BTSRel/ver: LN1.0/inc18
MO Class Parameter Id Parameter Name Abbreviated Name 3GPP Name Data Type StatusLNBTS 53084 QCI qci Number proposal
LNBTS 53104 RRC Guard Timer R rrcGuardTimer Number approved
LNBTS 53115 Handover Cancel La tX2RelocHold Number proposal
Hidden Description Short Description Additional Informationproposal QoS Class Identifier QoS Class Identifier Author: Tillmann Richter (C
approved
proposal Author: Mayer Walter (C-Pla
proposal Handover margin for better cell HO. Author: Mayer Walter (C-Pl
proposal Author: Mayer Walter (C-Pl
This timer is started when an RRC message for setup, modification or release of a radio bearer is sent to the UE. When the timer expires, the corresponding procedure is aborted.
RRC guard timer for outgoing radio bearer requests
This timer is started in the source eNB when the X2AP: HANDOVER CANCEL message is sent to the target eNB and is typically stopped when the X2AP: HANDOVER REQUEST ACKNOWLEDGE or X2AP: HANDOVER PREPARATION FAILURE message is received.When the timer expires X2 signalling connections at Source eNB shall be closed. Parameter is vendor specific
Spare time at source side after sent of X2AP: HANDOVER CANCEL for Inter eNB Handover
Handover margin for better cell HO. Used in measurement event type A3 where the event is triggered when the neighbor cell becomes A3 offset better than the serving cell. The actual value is parameter value multiplied by 0.5 dB.
Defines the maximum number of measurement reports that will be sent as long as the specific criteria for the measurement event A3 is met.
Defines the maximum number of measurement reports that will be sent as long as the specific criteria for the measurement event A3 is met.
proposal Author: Mayer Walter (C-Pla
proposal Author: Mayer Walter (C-Pla
proposal Author: Mayer Walter (C-Pl
proposal Author: Mayer Walter (C-Pla
proposal Author: Mayer Walter (C-Pl
Defines the interval with which measurement reports are repeatedly sent as long as the specific criteria for the measurement event A3 is met. Value definitions as stated in 3GPP TS36.331: value MS120 corresponds to 120 ms, MS240 to 240 ms and so on, while value MIN1 corresponds to 1 min, MIN6 to 6 min and so on.
Defines the interval with which measurement reports are sent as long as the specific criteria for the measurement event A3 is met.
Time for which the specific criteria for the measurement event A3 must be met in order to trigger a measurement report. Value definitions as stated in 3GPP TS36.331: value MS0 corresponds to 0 ms, MS40 to 40 ms and so on.
Time for which the specific criteria for the measurement event A3 must be met in order to trigger a measurement report.
Defines the maximum number of measurement reports that will be sent as long as the specific criteria for the measurement event A5 is met.
Defines the maximum number of measurement reports that will be sent as long as the specific criteria for the measurement event A5 is met.
Defines the interval with which measurement reports are repeatedly sent as long as the specific criteria for the measurement event A5 is met. Value definitions as stated in 3GPP TS36.331: value MS120 corresponds to 120 ms, MS240 to 240 ms and so on, while value MIN1 corresponds to 1 min, MIN6 to 6 min and so on.
Defines the interval with which measurement reports are sent as long as the specific criteria for the measurement event A5 is met.
Receive level threshold for serving cell in A5 event. Used in measurement event type A5 where the event is triggered if the serving cell becomes worse than a5Threshold1 AND the neighbor cell becomes better than a5Threshold2. The actual threshold value is parameter value -140 dBm.
Receive level threshold for serving cell in A5 event.
proposal Author: Mayer Walter (C-Pl
proposal Author: Mayer Walter (C-Pl
proposal
proposal
proposal
proposal
proposal
Receive level threshold for neighbour cell in A5 event. Used in measurement event type A5 where the event is triggered if the serving cell becomes worse than a5Threshold1 AND the neighbor cell becomes better than a5Threshold2. The actual threshold value is parameter value -140 dBm.
Receive level threshold for neighbour cell in A5 event.
Time for which the specific criteria for the measurement event A5 must be met in order to trigger a measurement report. Value definitions as stated in 3GPP TS36.331: value MS0 corresponds to 0 ms, MS40 to 40 ms and so on.
Time for which the specific criteria for the measurement event A5 must be met in order to trigger a measurement report.
The Cell Reselection Timer (t-ReselectionEUTRAN) is multiplied with this factor if the UE is in Medium High Mobility state.
Cell Reselection Timer factor if the UE is in High Mobility state.
The Cell Reselection Timer (t-ReselectionEUTRAN) is multiplied with this factor if the UE is in Medium Mobility state.
Cell Reselection Timer factor if the UE is in Medium Mobility state.
The Cell Reselection Priority parameter defines the absolute priority of the serving layer. 0 means lowest priority.
Defines the absolute priority of the serving layer.
Cell which are 'cell reserved for operator use' are treated as barred by 'normal' UE without an USIMwith AC 11 or 15 inserted. UEs with AC 11 or 15 USIM inserted are specific operator Ues and thus allowed tocamp on and access such cells. Default value not reserved.Instance Number 1 of this list is related to the primary PLMN-Id.The remaining instances are related to the further PLMN-Ids.
Indicates if the cell is reserved for operator use.
Author: M. Guessregen (C-Plane)SFS abbrev. name:cellReservedForOperatorUse (internal)
The parameter defines cyclic prefix configuration/length for OFDM symbol in downlink and uplink.Parameter is vendor specific
Cyclic prefix length in downlink and uplink
Author: Tuomas Hakuli (U-Plane)SFS abbreviated name: cycConf (internal)
proposal
proposal Intra-Frequency Blacklisted Cell List
proposal
proposal
proposal
approved
proposal
proposal
approved
proposal
User can define lower cell output power by the cell power reduction. Reduction is set down from a antenna maximum TX power.
Sets the power reduction from a antenna maximum Tx power
Author: Marko Saarinen (U-plane);SFS abbreviated name: CELL_PWR_RED (internal)
Defines the Intra-Frequency Blacklisted Cell List.
Author: M. Gussregen (C-Plane)SFS abbrev. name:IntraFreqBlacklistedCellList (internal)
Defines the Intra-Frequency Neighbouring Cell List.
Intra-Frequency Neighbouring Cell List
The parameter defines a cell-specific offset (in dB) that is used in the cell reselection procedure.
Defines a cell-specific offset used for cell reselection.
Used to control cell reselection on intra-frequency cells when the highest ranked cell is barred, or is considered as barred by the UE, as specified in TS 36.304
Indicates if intra-frequency cell reselection is allowed or not
Author: M. Gussregen (C-Plane)SFS abbrev. name: intraFrequencyReselection (internal)
Preamble cyclic shift defines the configuration which is used for preamble generation. The configuration determines how many cyclic shifts are needed to generate preamble. Unrestricted set is supported. Configuration also defines the zero correlation zone and respective maximum cell range.
Defines the PRACH Cyclic Shift configuration for preamble generation
Defines allowed System frame and sub-frame numbers for random access attempts, and the preamble format.
Defines subframes and preamble format for random access attempt opportunities.
Author: Tuomas Hakuli (U-Plane)SFS abbreviated name: RL1_SFS
Range is restricted to two different ranges: 3-8 and 19-24 (internal)
First physical resource block available for PRACH in the UL system frequency band.
Defines the location in frequency for the PRACH transmissions.
Author: Tuomas Hakuli (U-Plane)SFS abbreviated name: PrachFrequencyOffset (internal)
High speed flag for PRACH preamble generation determines whether unrestricted or restricted set has to be used by UE. Unrestricted set, and thus parameter value false is supported.
High speed flag for PRACH preamble generation
The parameter Preamble Transmission Maximum defines the maximum number of random access transmissions. Note: The values n50, n100 and n200 shall not be used.
Defines the maximum number of random access transmissions.
Author: M. Gussregen (C-Plane)SFS abbrev. name: preambleTransMax (internal)
proposal
proposal
proposal
proposal
approved Author: Raimo Karjalainen (
proposal Author: Raimo Karjalainen
The Qhyst parameter provides the hysteresis value in dB for ranking criteria in the cell reselection procedure. Parameter is used to minimize pingpong.
Provides the hysteresis value for the cell reselection procedure.
Parameter defines an additional hysteresis value to be applied in High Mobility stateto the Cell Reselection Procedure Hysteresis Value (q-Hyst).Value db-6 corresponds to -6dB, db-4 corresponds to -4dB and so on.
Hysteresis value in High Mobility state applied to the Cell Reselection Procedure Hysteresis Value.
Author: M. Guessregen (C-Plane)SFS abbrev. name: sf-High (internal)
Parameter defines an additional hysteresis value to be applied in Medium Mobility stateto the Cell Reselection Procedure Hysteresis Value (q-Hyst).Value db-6 corresponds to -6dB, db-4 corresponds to -4dB and so on.
Hysteresis value in Medium Mobility state applied to the Cell Reselection Procedure Hysteresis Value.
Author: M. Guessregen (C-Plane)SFS abbrev. name: sf-Medium (internal)
Specifies the minimum required Rx RSRP level for the intra-frequency neighbouring E-UTRA cells.(Qrxlevmin in 36.304)
Indicates the minimum required RX level in the cell (dBm) for intra-frequency
Author: M. Gussregen (C-Plane)SFS abbrev. name:q-RxLevMin-intraFrequency (internal)
The Random Access Backoff parameter defines the backoff in TTIs that should be applied if a random access fails.
Defines the backoff that should be applied if a random access fails.
This parameter is used to determine the total number of non dedicated RA preambles that UE can select from (i.e. for contention based RA). The minimum cannot be zero.
Defines the total number of RA Preambles that a UE can select.
approved Author: Tuomas Hakuli (U-P
proposal
proposal
proposal
Preable generation is started from the Root Sequence which is pointed by the logical root sequence number. 64 preambles can be transmitted in the PRACH frame. If one root is not enough to generate all the 64 preambles, then the concecutive number is selected until the full set is generated. RACH root sequence is cell specific information and neighbouring cells shall have a different value. RACH root sequence is transmitted in system information.
RACH Root Sequence defines the physical root sequence number which is used as starting point to generate preamble sequencies
The Sintrasearch parameter defines the threshold (in dB) for intra frequency measurements. UE can omit measurements of intra-frequency neighbor cells if serving cell is above a certain threshold.
Defines the threshold (in dB) for intra frequency measurements
Author: M. Gussregen (C-Plane)SFS abbrev. name:s-IntraSearch (internal)
The Timer T300 supervises the RRC Connnection Establishment procedure. Start: Transmission of RRCConnectionRequestStop: Reception of RRCConnectionSetup or RRCConnectionReject message,cell re-selection and upon abortion of connection establishment by upper layersAt expiry: Perform the actions as specified in 36.331, 5.3.3.6
T300 supervises the RRC Connnection Establishment procedure.
Author: M. Guessregen (C-Plane)SFS abbrev. name: t300 (internal)
The Timer T301 supervises the RRC Connnection Re-Establishment procedure. Start: Transmission of RRCConnectionReestabilshmentRequestStop: Reception of RRCConnectionReestablishment or RRCConnectionReestablishmentReject message as well as when the selected cell becomes unsuitableAt expiry: Go to RRC_IDLE
T301 supervises the RRC Connnection Establishment procedure.
Author: M. Guessregen (C-Plane)SFS abbrev. name: t301 (internal)
proposal
proposal Author: Mayer Walter (C-Pl
proposal
proposal
proposal
proposal
proposal
proposal
eNB sends this parameter to UE in the message RRC CONNECTION REJECT.UE will consider access to the cell as barred for the time specified by t302.
T302 suppresses reselection of a cell for a short while.
The Timer T304 supervises the successful completion of handover or cell change
The Timer T304 supervises the successful completion of handover or cell change
The Timer T310 supervises the recovery from physical layer problems.
T310 supervises the recovery from physical layer problems.
The Timer T311 supervises the RRC Connnection Re-Establishment.
T311 supervises the RRC Connnection Re-Establishment.
Author: M. Gussregen (C-Plane)SFS abbrev. name: t311 (internal)
Timer TCRmax defines the duration for evaluating the criteria to enter mobility states. For idle mode it corresponds to TCRmax in TS 36.304.
Defines the duration for evaluating the criteria to enter mobility states.
The Timer TCRmaxHyst defines the additional duration for evaluating the criteria to enter normal mobility state. For idle mode it corresponds to TCRmaxHyst in TS 36.304.
Defines the additional duration for evaluating the criteria to enter normal mobility state.
The Treselection parameter defines the cell reselection timer value. It allows averaging of the target cell quality before cell reselection is performed.
Defines the cell reselection timer value.
The Preamble Initial Received Target Power parameter defines the initial power for Random Access Preamble transmission.
Defines the initial power for Random Access Preamble transmission.(dBm)
Multiplicity Related Functions System information Related Parameters1 E-RAB Control
1
1 Handover Control
1 Handover Control
1 Handover Control
1 Handover Control
1 Handover Control
1 Handover Control
1 Handover Control
1 Handover Control
1 Handover Control
1 Handover Control
1 System Information Broadcast
1 System Information Broadcast
1
6 System Information Broadcast
1 Packet Scheduler
1 Power Control
16 System Information Broadcast
16
1
1 System Information Broadcast
1 Random Access
1 Random Access
1 Packet Scheduler, Random Access
1 Random Access
1 System Information Broadcast
ulChBw of LNCEL - null (public)
1
1 System Information Broadcast
1 System Information Broadcast
1 System Information Broadcast
1
1
1 Random Access
1 System Information Broadcast
1 System Information Broadcast
1 System Information Broadcast
1
1 Handover Control
1
1 System Information Broadcast
1
1
1
1
Description of Parameter Relationships Group Classification Interfacesno relations EM <-> LTE
no relations EM <-> LTE
no relations EM <-> LTE
no relations EM <-> LTE
no relations EM <-> LTE
no relations EM <-> LTE
no relations EM <-> LTE
no relations EM <-> LTE
no relations EM <-> LTE
no relations EM <-> LTE
no relations EM <-> LTE
no relations EM <-> LTE
EM <-> LTE
EM <-> LTE
EM <-> LTE
no relations EM <-> LTE
LTE BTS <-
LTE BTS <-
no relations EM <-> LTE BTS, LTE BTS <-> RAC, RAC <-> RACApp
EM <-> LTE BTS, LTE BTS <-> RAC, RAC <-> RACApp
LTE BTS <-
no relations EM <-> LTE
LTE BTS <-
LTE BTS <-
LTE BTS <-
LTE BTS <-> EM, LTE BTS <-> RAC, RACApp <-> RAC
no relations EM <-> LTE
Range: 0,1,2, ulChBw in PRBs - 8, ulChBw in PRBs -7, ulChBw in PRBs -6Default value: 1
-24 dB (0), -22 dB (1), -20 dB (2), -18 dB (3), -16 dB (4), -14 dB (5), -12 dB (6), -10 dB (7), -8 dB (8), -6 dB (9), -5 dB (10), -4 dB (11), -3 dB (12), -2 dB (13), -1 dB (14), 0 dB (15), 1 dB (16), 2 dB (17), 3 dB (18), 4 dB (19), 5 dB (20), 6 dB (21), 8 dB (22), 10 dB (23), 12 dB (24), 14 dB (25), 16 dB (26), 18 dB (27), 20 dB (
- Not reserved for operator use Mandatory BTS restart needed
- Mandatory Not modifiable
- internal_v Mandatory BTS restart needed
Mandatory BTS restart needed
Mandatory BTS restart needed
0 dB (15) 0 dB means no offset Mandatory BTS restart needed
- Mandatory BTS restart needed
- internal_v Mandatory BTS restart needed
3 internal_v Mandatory BTS restart needed
1 internal_v Mandatory BTS restart needed
false High speed is not supported Mandatory BTS restart needed
8 (5) 8 Mandatory BTS restart needed
- Mandatory BTS restart needed
- Mandatory BTS restart needed
- Mandatory BTS restart needed
- internal_v Mandatory BTS restart needed
- Mandatory BTS restart needed
40 (9) Mandatory BTS restart needed
- internal_v Mandatory BTS restart needed
- internal_v Mandatory BTS restart needed
- Mandatory BTS restart needed
- Mandatory BTS restart needed
8000 ms internal_v Mandatory BTS restart needed
200ms (3) Mandatory BTS restart needed
- Mandatory BTS restart needed
- Mandatory BTS restart needed
- Mandatory BTS restart needed
- Mandatory BTS restart needed
- internal_v Mandatory BTS restart needed
-104 dBm (8) Mandatory BTS restart needed
Modified Related Features Calculation References Internal NE TypeLTE5 Radio bearer and S1 bearer eNSN reference: TF_LTE_SFS_BEARERMAN.300 (internal), 3GPP Reference: TS 23.203 (public)
LTE5 Radio bearer and S1 bearer eNSN reference: TF_LTE_SFS_BEARERMAN.424, Baseline1.0 (V2.0) (internal)
BTS restart needed LTE53 Intra and inter eNB handoverNSN reference: TF_LTE_SFS_MM.1444, Baseline 4.1 (V6.1) (internal), 3GPP Reference: TS 36.331 (internal)
This timer is started when an RRC message for setup, modification or release of a radio bearer is sent to the UE. When the timer expires, the corresponding procedure is aborted.
This timer is started in the source eNB when the X2AP: HANDOVER CANCEL message is sent to the target eNB and is typically stopped when the X2AP: HANDOVER REQUEST ACKNOWLEDGE or X2AP: HANDOVER PREPARATION FAILURE message is received.When the timer expires X2 signalling connections at Source eNB shall be closed. Parameter is vendor specific
Handover margin for better cell HO. Used in measurement event type A3 where the event is triggered when the neighbor cell becomes A3 offset better than the serving cell. The actual value is parameter value multiplied by 0.5 dB.
Defines the maximum number of measurement reports that will be sent as long as the specific criteria for the measurement event A3 is met.
Defines the interval with which measurement reports are repeatedly sent as long as the specific criteria for the measurement event A3 is met. Value definitions as stated in 3GPP TS36.331: value MS120 corresponds to 120 ms, MS240 to 240 ms and so on, while value MIN1 corresponds to 1 min, MIN6 to 6 min and so on.
Time for which the specific criteria for the measurement event A3 must be met in order to trigger a measurement report. Value definitions as stated in 3GPP TS36.331: value MS0 corresponds to 0 ms, MS40 to 40 ms and so on.
Defines the maximum number of measurement reports that will be sent as long as the specific criteria for the measurement event A5 is met.
Defines the interval with which measurement reports are repeatedly sent as long as the specific criteria for the measurement event A5 is met. Value definitions as stated in 3GPP TS36.331: value MS120 corresponds to 120 ms, MS240 to 240 ms and so on, while value MIN1 corresponds to 1 min, MIN6 to 6 min and so on.
Receive level threshold for serving cell in A5 event. Used in measurement event type A5 where the event is triggered if the serving cell becomes worse than a5Threshold1 AND the neighbor cell becomes better than a5Threshold2. The actual threshold value is parameter value -140 dBm.
Receive level threshold for neighbour cell in A5 event. Used in measurement event type A5 where the event is triggered if the serving cell becomes worse than a5Threshold1 AND the neighbor cell becomes better than a5Threshold2. The actual threshold value is parameter value -140 dBm.
Time for which the specific criteria for the measurement event A5 must be met in order to trigger a measurement report. Value definitions as stated in 3GPP TS36.331: value MS0 corresponds to 0 ms, MS40 to 40 ms and so on.
The Cell Reselection Timer (t-ReselectionEUTRAN) is multiplied with this factor if the UE is in Medium High Mobility state.
The Cell Reselection Timer (t-ReselectionEUTRAN) is multiplied with this factor if the UE is in Medium Mobility state.
The Cell Reselection Priority parameter defines the absolute priority of the serving layer. 0 means lowest priority.
Cell which are 'cell reserved for operator use' are treated as barred by 'normal' UE without an USIMwith AC 11 or 15 inserted. UEs with AC 11 or 15 USIM inserted are specific operator Ues and thus allowed tocamp on and access such cells. Default value not reserved.Instance Number 1 of this list is related to the primary PLMN-Id.The remaining instances are related to the further PLMN-Ids.
Defines the Intra-Frequency Blacklisted Cell List.Defines the Intra-Frequency Neighbouring Cell List.
First physical resource block available for PRACH in the UL system frequency band.
The parameter defines cyclic prefix configuration/length for OFDM symbol in downlink and uplink.Parameter is vendor specific
User can define lower cell output power by the cell power reduction. Reduction is set down from a antenna maximum TX power.
The parameter defines a cell-specific offset (in dB) that is used in the cell reselection procedure.
Used to control cell reselection on intra-frequency cells when the highest ranked cell is barred, or is considered as barred by the UE, as specified in TS 36.304
Preamble cyclic shift defines the configuration which is used for preamble generation. The configuration determines how many cyclic shifts are needed to generate preamble. Unrestricted set is supported. Configuration also defines the zero correlation zone and respective maximum cell range.
Defines allowed System frame and sub-frame numbers for random access attempts, and the preamble format.
High speed flag for PRACH preamble generation determines whether unrestricted or restricted set has to be used by UE. Unrestricted set, and thus parameter value false is supported.
The parameter Preamble Transmission Maximum defines the maximum number of random access transmissions. Note: The values n50, n100 and n200 shall not be used.
The Qhyst parameter provides the hysteresis value in dB for ranking criteria in the cell reselection procedure. Parameter is used to minimize pingpong.
Parameter defines an additional hysteresis value to be applied in High Mobility stateto the Cell Reselection Procedure Hysteresis Value (q-Hyst).Value db-6 corresponds to -6dB, db-4 corresponds to -4dB and so on.
Parameter defines an additional hysteresis value to be applied in Medium Mobility stateto the Cell Reselection Procedure Hysteresis Value (q-Hyst).Value db-6 corresponds to -6dB, db-4 corresponds to -4dB and so on.
Specifies the minimum required Rx RSRP level for the intra-frequency neighbouring E-UTRA cells.(Qrxlevmin in 36.304)
The Random Access Backoff parameter defines the backoff in TTIs that should be applied if a random access fails.
This parameter is used to determine the total number of non dedicated RA preambles that UE can select from (i.e. for contention based RA). The minimum cannot be zero.
Preable generation is started from the Root Sequence which is pointed by the logical root sequence number. 64 preambles can be transmitted in the PRACH frame. If one root is not enough to generate all the 64 preambles, then the concecutive number is selected until the full set is generated. RACH root sequence is cell specific information and neighbouring cells shall have a different value. RACH root sequence is transmitted in system information.
The Sintrasearch parameter defines the threshold (in dB) for intra frequency measurements. UE can omit measurements of intra-frequency neighbor cells if serving cell is above a certain threshold.
The Timer T300 supervises the RRC Connnection Establishment procedure. Start: Transmission of RRCConnectionRequestStop: Reception of RRCConnectionSetup or RRCConnectionReject message,cell re-selection and upon abortion of connection establishment by upper layersAt expiry: Perform the actions as specified in 36.331, 5.3.3.6
The Timer T304 supervises the successful completion of handover or cell changeThe Timer T310 supervises the recovery from physical layer problems.The Timer T311 supervises the RRC Connnection Re-Establishment.
The Timer T301 supervises the RRC Connnection Re-Establishment procedure. Start: Transmission of RRCConnectionReestabilshmentRequestStop: Reception of RRCConnectionReestablishment or RRCConnectionReestablishmentReject message as well as when the selected cell becomes unsuitableAt expiry: Go to RRC_IDLE
eNB sends this parameter to UE in the message RRC CONNECTION REJECT.UE will consider access to the cell as barred for the time specified by t302.
Timer TCRmax defines the duration for evaluating the criteria to enter mobility states. For idle mode it corresponds to TCRmax in TS 36.304.
The Timer TCRmaxHyst defines the additional duration for evaluating the criteria to enter normal mobility state. For idle mode it corresponds to TCRmaxHyst in TS 36.304.
The Treselection parameter defines the cell reselection timer value. It allows averaging of the target cell quality before cell reselection is performed.
The Preamble Initial Received Target Power parameter defines the initial power for Random Access Preamble transmission.
Short DescriptionQoS Class Identifier
RRC guard timer for outgoing radio bearer requests
Handover margin for better cell HO.
Receive level threshold for serving cell in A5 event.
Receive level threshold for neighbour cell in A5 event.
Cell Reselection Timer factor if the UE is in High Mobility state.
Cell Reselection Timer factor if the UE is in Medium Mobility state.
Defines the absolute priority of the serving layer.
Indicates if the cell is reserved for operator use.
Spare time at source side after sent of X2AP: HANDOVER CANCEL for Inter eNB Handover
Defines the maximum number of measurement reports that will be sent as long as the specific criteria for the measurement event A3 is met.
Defines the interval with which measurement reports are sent as long as the specific criteria for the measurement event A3 is met.
Time for which the specific criteria for the measurement event A3 must be met in order to trigger a measurement report.
Defines the maximum number of measurement reports that will be sent as long as the specific criteria for the measurement event A5 is met.
Defines the interval with which measurement reports are sent as long as the specific criteria for the measurement event A5 is met.
Time for which the specific criteria for the measurement event A5 must be met in order to trigger a measurement report.
Cyclic prefix length in downlink and uplink
Sets the power reduction from a antenna maximum Tx powerIntra-Frequency Blacklisted Cell ListIntra-Frequency Neighbouring Cell List
Defines a cell-specific offset used for cell reselection.
Indicates if intra-frequency cell reselection is allowed or not
Defines the PRACH Cyclic Shift configuration for preamble generation
Defines the location in frequency for the PRACH transmissions.
High speed flag for PRACH preamble generation
Defines the maximum number of random access transmissions.
Provides the hysteresis value for the cell reselection procedure.
Defines the backoff that should be applied if a random access fails.
Defines the total number of RA Preambles that a UE can select.
Defines the threshold (in dB) for intra frequency measurements
T300 supervises the RRC Connnection Establishment procedure.
Defines subframes and preamble format for random access attempt opportunities.
Hysteresis value in High Mobility state applied to the Cell Reselection Procedure Hysteresis Value.
Hysteresis value in Medium Mobility state applied to the Cell Reselection Procedure Hysteresis Value.
Indicates the minimum required RX level in the cell (dBm) for intra-frequency
RACH Root Sequence defines the physical root sequence number which is used as starting point to generate preamble sequencies
T301 supervises the RRC Connnection Establishment procedure.
T302 suppresses reselection of a cell for a short while.
T310 supervises the recovery from physical layer problems.T311 supervises the RRC Connnection Re-Establishment.
Defines the duration for evaluating the criteria to enter mobility states.
Defines the cell reselection timer value.
The Timer T304 supervises the successful completion of handover or cell change
Defines the additional duration for evaluating the criteria to enter normal mobility state.
Defines the initial power for Random Access Preamble transmission.(dBm)
-24 dB (0), -22 dB (1), -20 dB (2), -18 dB (3), -16 dB (4), -14 dB (5), -12 dB (6), -10 dB (7), -8 dB (8), -6 dB (9), -5 dB (10), -4 dB (11), -3 dB (12), -2 dB (13), -1 dB (14), 0 dB (15), 1 dB (16), 2 dB (17), 3 dB (18), 4 dB (19), 5 dB (20), 6 dB (21), 8 dB (22), 10 dB (23), 12 dB (24), 14 dB (25), 16 dB (26), 18 dB (27), 20 dB (