NOVES SOLUCIONS DE DISSENY HIGIÈNIC DE DRENATGES SEMINARI ORGANITZAT PER INNOVACC-NOV/2018
NOVES SOLUCIONS DE DISSENY HIGIÈNIC DE DRENATGES
SEMINARI ORGANITZAT PER INNOVACC-NOV/2018
ACO-Presentación Empresa
ACO-System Chain
collect: captar y recoger agua
clean:pretratamiento y proceso
hold:atenuar y contener
release: bombeo, descarga y reutilización
ACO Service.
Industrial & Commercial Drainage
Key requirements for industrial drainage
Drainage can play an important role
in successful food processing
and/or commercial food preparation:
The Industry essential
requirements
for drainage:
HYGIENIC
DESIGN
Hygienic design and easy effective
cleaning and maintenance to prevent
food contamination
DURABILITY Durable drainage performance
SAFETYSafety design to minimize
the risk of injury
CERTIFICATION Certified solutions are preferred
Food industry standards for hygienic design
Hygienic design
Food companies and professional
associations such as EHEDG (European
Hygienic Engineering and Design Group)
define standards and guidelines
for hygienic design and maintenance
of the food processing environment,
machineries, floor and drainage
included.
HYGIENICDESIGN
ACO & EHEDG
European Hygienic Engineering & Design Group (EHEDG) es un
consorcio de fabricantes de equipos, industrias alimentarias, institutos
de investigación y autoridades públicas sanitarias, fundado en 1989
con la finalidad de promover la higiene durante el procesado y
envasado de alimentos.
El principal objetivo de EHEDG es la promoción de la inocuidad
alimentaria, a través de la mejora del diseño y la ingeniería higiénica
en todos los aspectos del procesado de alimentos.
ACO & EHEDG
EHEDG apoya firmemente la legislación Europea, que requiere que el manipulado,
preparado, procesado y envasado de alimentos se realicen higiénicamente, con
maquinaria y condiciones higiénicas (Directiva 2006/42/EC para Maquinaria, normas
EN 1672-2 y EN ISO 14159).
https://www.ehedg.org/
Asociados a EHEDG
Hygienic design principles
HYGIENICDESIGN
ACO & Diseño Higiénico
• Facilita la limpieza, reduciendo el tiempo destinado a ello.
• Ahorro en productos de desinfección
• Reduce el consumo de agua entre 30-40% en los procesos de limpieza (proyecto ECODHYBAT)
Hygienic design applied on gratings
HYGIENICDESIGNFrameless design allows solid waste
to enter the drainage more easily
Fully welded bars with
internal corner radii
at least 3mm
Electropolished surface
Hygienic design applied on covers
HYGIENICDESIGN
Fully welded support
bars with internal
corner radii
at least 3mmSand blasted surface
Durable drainage performance - Material
Essential requirements
for drainage material in
food production areas are:
�Durable performance
�Corrosion resistance
�Elimination of hazards related
to hygiene
EHEDG guidelines define
stainless steel as the proper
material for drainage
HYGIENICDESIGN
ACO stainless steel products are manufactured from
austenitic stainless steel grades:
�1.4301 (AISI 304), general purpose steel
with excellent corrosion resistance
�1.4404 (AISI 316L) superior corrosion resistance
to Grade 304 for particularly aggressive applications
Safety design applied on gratings
HYGIENICDESIGN
Slip resistant design
assured by small
wedges in grating bars
Safe handling due to round edges
Easier handling and cleaning
due to lengths up to 500 mm
Product certificates
ACO channels and ACO hygienic
gullies tested and certified acc. to
�EN 1253 and EN 1433.
ACO pipes tested and certified
according to:
�EN 1124 full compliance
�ISO 9001 Certified producer
�International authorized bodies
certification (DNV, DI, ABS…)
�Special test certificates available (push
fit, tightness)
�Special fire certificates for Marine
applications
Portfolio
ACO modular channel
ACO slot channelACO box channelACO hygienic gully
ACO pipeACO design channel
ACO Service.
Fixed height solution
Fixed height gullies
convenient and free-standing units
suitable for cementitious, resin or tiled
in areas where waterproofing is
independent of the gully body.
Gratings
Foul air trap
ACO gully body
Silt basket
Foul air trap support
Telescopic solution
Telescopic gullies
can be installed either with a gully top
or ACO channel in most flooring
constructions, including floors with
waterproofing membranes when the
exact height of the floor is unknown.
Foul air trap
ACO gully body
Foul air trap support
Gratings
Silt basket
Friction ring
Gully top
High capacity gully
Specially Recommended for point downloads.
ACO gully gratings and covers
ACO hygienic frameless
ladder grating
ACO hygienic
cast grating
ACO hygienic
odour proof cover
ACO hygienic
slot cover
ACO heelsafe
grating
ACO mesh
grating
ACO quadrato
grating
ACO multi-slot 5
grating
ACO hygienic
ladder grating
Channel profile
V-shape
External width 150, 200 or 300 mm
X-shape
External width 400, 500, 600 or 800 mm
ACO box channel gratings and covers
ACO mesh gratingACO hygienic ladder gratingACO hygienic frameless ladder grating
ACO hygienic slot cover ACO hygienic cast grating
ACO pipe push–fit system
ACO pipe push–fit system
is reliable for vacuum and gravity piping
systems. ACO pipe double lip seal
delivers ultimate system reliability.
The unique and sophisticated design
of lips and cavities provides tight
connections.
Push-fit advantages
�Easy to assemble
�Time saving
�Cost saving
�Tight connection
Sealing options
- Ethylene Propylene Diene MonomerEPDM
- Fluor elastomer / FKMVITON
- Nitrile Butadiene RubberNBR
What are the differences?
� Resistance
� Application segments
� Price
ACO kerb
ACOWall protection
ACO kerb product groups
ACO kerb PB ACO kerb PBplain
ACO kerb SSsingle side
ACO kerb PBdouble side
Polymer concrete Stainless steel (316 AISI)
ACO kerb introduction
ACO kerb is a reliable wall protection
that prevents walls from impacts, water
or chemical ingress, or other damages
associated with traffic and production
process.
It is suitable for any processing area.
ACO Top tek
ACOWaterproof Tops
ACO Top tek
ACO Top tek
ACOGrease Separators
ACO Grease Separators
Drainage System Assessment (DSA) A complex diagnostic service
Supported by
ACO,
Creating The Future of Drainage.