Top Banner
Page 1 of 4 One Metropolitan Square 211 North Broadway Suite 1900 Saint Louis, Missouri 63102 314.241.8188 Main 314.241.0125 Fax www.kai)db.com DATE OF ISSUE: October 16, 2012 ADDENDUM NO. 01 Project: North Sarah Phase 2 OnSite Building Improvements (KAI Project No. 10)11029) Prepared By: KAI Design & Build 211 N. Broadway, Suite 1900 St. Louis, MO 63102 Phone (314) 241)8188 Fax (314) 241)0125 I. This Addendum modifies the Contract Documents and is hereby made a part of the Proposal, Bidding and Contract Documents. II. Bidders must acknowledge receipt of this Addendum in the Bid Proposal Form. Failure to do so may subject Bidder to disqualification. III. All incidental work necessitated by this addendum as required to properly complete the work shall be included in the Bids, even though not specifically stated in the Addendum. GENERAL INFORMATION Invitation to Bid & general Bid Instructions Attached to this addendum is a copy of the meeting handout distributed by Brinkmann/Simms which includes general information related to their bid process. PreBid Meeting Signin Sheets Attached to this addendum is a copy of the pre)bid meeting sign in sheets. PROJECT MANUAL ADJUSTMENTS (Note: Only specifications with major adjustments or alterations are attached to this document) 012100 Updated Allowance #1 to $35,000. 012300 Added alternates E8)E12 and F6)F7. DRAWING ADJUSTMENTS (Note: Only drawing sheets with major adjustments or alterations are attached to this document) SKA3031 Added stair finishes to townhome unit finish schedule. SKA4041 Added detail 19) MU corridor ceiling diagram. Typical at all MU building corridors.
34

North Sarah Phase II Prelims

Nov 08, 2014

Download

Documents

Paul Sableman

From Brinkman Construction's Website
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript

DATE OF ISSUE: October 16, 2012 ADDENDUM NO. 01 Project: Prepared By: North Sarah Phase 2 On Site Building Improvements (KAI Project No. 10)11029) KAI Design & Build 211 N. Broadway, Suite 1900 St. Louis, MO 63102 Phone (314) 241)8188 Fax (314) 241)0125

I. II. III.

This Addendum modifies the Contract Documents and is hereby made a part of the Proposal, Bidding and Contract Documents. Bidders must acknowledge receipt of this Addendum in the Bid Proposal Form. Failure to do so may subject Bidder to disqualification. All incidental work necessitated by this addendum as required to properly complete the work shall be included in the Bids, even though not specifically stated in the Addendum.

GENERAL INFORMATIONInvitation to Bid & general Bid Instructions Attached to this addendum is a copy of the meeting handout distributed by Brinkmann/Simms which includes general information related to their bid process. Pre Bid Meeting Sign in Sheets Attached to this addendum is a copy of the pre)bid meeting sign in sheets.

PROJECT MANUAL ADJUSTMENTS(Note: Only specifications with major adjustments or alterations are attached to this document) 012100 Updated Allowance #1 to $35,000. 012300 Added alternates E8)E12 and F6)F7.

DRAWING ADJUSTMENTS(Note: Only drawing sheets with major adjustments or alterations are attached to this document) SK A3 03 1 Added stair finishes to townhome unit finish schedule. SK A4 04 1 Added detail 19) MU corridor ceiling diagram. Typical at all MU building corridors.

Page 1 of 4

One Metropolitan Square 211 North Broadway Suite 1900 Saint Louis, Missouri 63102 314.241.8188 Main 314.241.0125 Fax www.kai)db.com

SK F M1 01 01 Switched location of CU)2 (right of center of building) with CU)3 (second from the right), which shortened the length of the refrigerant lines. Added F)3 furnace designation tags to the three bedroom unit located at the right end of this building. Added 3 round sizes to the water heater combustion flue piping to the three bedroom unit located at the right end of this building. SK F M1 01 02 Added F)3 furnace designation tags to the three bedroom unit located at the left end of this building. Added 3 round sizes to the water heater combustion flue piping to the three bedroom units located at the left end of this building. Added keyed note 8, which referred to Architectural and Civil Sheets, A1)00 and C3.0,for gas meter locations. A1 01 Added gas meter and electric meter locations to buildings for clarity and coordination. A1 02 Added gas meter and electric meter locations to buildings for clarity and coordination. A1 03 Added gas meter and electric meter locations to buildings for clarity and coordination. A E1 01, B E1 01, D E1 01, F E1 01 Omit phrase , ONE ACTIVE, ONE SPARE from Telephone note and Cable Television note on Electrical Elevation. MC E1 01 Change switch in Elev Equip Room from an Occupancy Sensor to a standard toggle switch. Change Standard Receptacle in Elev Equip Room to a GFI receptacle. E1 00 Changed some underground conduit routing. Showed conduits connecting pedestals to utility poles for Charter. Relocated conduit for AT&Ts connection point. E1 01 Changed some underground conduit routing. Changed location of utility pole for Charter and Ameren connections. Relocated conduit for AT&Ts direct bore to a different manhole. M1 01 Deleted the use of elastomeric insulation on all combustion air and exhaust flues including on Detail A on sheet M1)01, sheet A)M1)01 ) keyed note 8, B)M1)01 ) keyed note 10, sheet DM1) 01 ) keyed note 10, F)M1)01 ) keyed note 10 and sheet MA)M1)02 keyed notes 2,3 and 4. A M1 01, B M1 01, D M1 01, F M1 01, MA M1 01, MC M1 01, MD M1 01 Clarified keyed note to refer to Architectural and Civil Sheets, A1)00 and C3.0, for gas meter locations typical of sheets MD M1 01 Corrected wrong keyed note 13 near bottom left corner of this sheet to keyed note 4, which references gas meter locations. Page 2 of 4

One Metropolitan Square 211 North Broadway Suite 1900 Saint Louis, Missouri 63102 314.241.8188 Main 314.241.0125 Fax www.kai)db.com

MA M1 01 Furnace, F)6 shall have 3 round combustion and 3 round flue piping. All other furnace combustion and flue piping shall be 2 round combustion and 2 round flue piping. MA M1 01, MC M1 01, MC M1 02, MD M1 01 Change 3 round combustion and 3 round flue piping to 2 round combustion and 2 round flue piping. MB E1 00 Revised j)boxes for signage & lighting layout in the retail space. Provided circuiting for lights and receptacles in the lobby, utility/maint. rooms, retail space, and both stairwells. Added note at unit panel that reads as follows: TO METER CENTER MCMU)B (TYP. FOR UNIT PANELS), SEE DWG MB)E1)05. Identified exterior meter center and panel HP1 on floor plan. Added panels RP1, PE1, & Bussmann power module for the elevator to the floor plan. Provided lighting and disconnect switch for sump pump in elevator shaft. Relocated FACP to Lobby. MB E1 01 Provided circuiting for lights and receptacles in the corridors, community areas, and both stairwells. Added note at unit panel that reads as follows: TO METER CENTER MCMU)B (TYP. FOR UNIT PANELS), SEE DWG MB)E1)05. Added notes security camera rough)in & corresponding cables. MB E1 02 Provided circuiting for lights and receptacles in the corridors, community areas, and both stairwells. Added note at unit panel that reads as follows: TO METER CENTER MCMU)B (TYP. FOR UNIT PANELS), SEE DWG MB)E1)05. Provided heat detector at top of elevator shaft. MB E1 03 Provided circuiting of RTU)2, condensing units for retail space, & roof)top convenience receptacles. Added photocell for control of exterior lighting and conduits for irrigation controller sensor & future photo)voltaic circuits. Corrected number of disconnect switches for roof)top condensing units. MB E1 05 Changed one)line diagram to show new panel PE1 and revised wiring of panels HP1 & Bussmann power module PS2. Added panel schedules for HP1, HPMB, RP1, and PE1 to sheet. MB M1 01 Changed furnace tag on retail space from F/5 to F/6. Added exhaust to utility room 120. Added Unit Heater to maintenance room 121. Added Unit Heater to stair area 116. Added thermostat, supply and return ducts to Lobby #117. Revised keyed notes # 4 through #15. Added call)out for water heater location. Added three inch diameter furnace combustion air and exhaust ducts for each unit per key note #11. Added thermostat for retail sale area. MB M1 02 Revised exhaust discharges for Unit #206 and Unit # 210. Added equipment tag (F/2) to furnace in Unit #206 and Unit #210. Added equipment tag A/) to return grille in Unit #206 and Unit #210. Added supply and return air to community room #214, mechanical room # 215, and storage Page 3 of 4

One Metropolitan Square 211 North Broadway Suite 1900 Saint Louis, Missouri 63102 314.241.8188 Main 314.241.0125 Fax www.kai)db.com

area #216. Revised equipment tag for furnace for corridor area #200 from (F/6) and (F/10) to (F/1. Revised keyed notes #4 through #15. Added call)out for water heater location. Added three inch diameter furnace combustion air and exhaust ducts for each unit per key note # 11. Added supply and return air ducts to Lobby #213. Deleted 29 linear feet of 10X10 duct, one eight inch diameter tap and one duffer from corridor area #200. MB M1 03 Revised exhaust discharges for Unit #306 and Unit # 310. Added equipment tag (F/2) to furnace in Unit #306 and Unit #310. Added equipment tag A/) to return grille in Unit #306 and Unit #310. Added supply and return air to Lobby #116, mechanical room # 315, and storage area #316. Revised equipment tag for furnace for third floor corridor area from (F/6) and (F/10) to (F/1). Revised keyed notes #4 through #15. Added call)out for water heater location. Added three inch diameter furnace combustion air and exhaust ducts for each unit per key note # 11. Added supply and return air ducts to lobby area. MB M1 04 Replaced key note #4 with key note #12 and added (future retail) to CU#5 and CU#6. Added the word corridor to CU 1 #200 for corridor. Added offset and labels to concentric vents. Added key note #12, #13, and #14 to mechanical keyed notes. Added call)out for roof hatch. Revised keyed notes #4 through #15. Added post hydrant (HY)1) and cold water down call outs. MB P1 00 Revised fire and domestic water layout entering the building. Added note for overhead galvanized run in joist space. Added floor drain to utility room #120. MB P1 01 Added call outs for 1 CW UP and Down for water service. MB P1 02 Added call outs for 1 CW UP and Down for water service. MB P1 05 Added mod basin to mechanical room #215. MB P1 10 Added tag for floor cleanout in retail sales area. Added note All PVC to be run in joist space. No exposed PVC below drywall ceiling. Revised sanitary discharge layout for Unit #106. Added floor drain for future retail furnace. Added labels for 2 vent up and 4 waste up and down for Unit #107. Added ground cleanout outside of Unit #108 and Unit # 101. Added floor cleanout in stair area #116. Revised sanitary discharge layout for Unit #109.

END OF ADDENDUM 01

Page 4 of 4

One Metropolitan Square 211 North Broadway Suite 1900 Saint Louis, Missouri 63102 314.241.8188 Main 314.241.0125 Fax www.kai)db.com

North Sarah Phase II Pre-Bid Meeting McCormack House 10/2/12Name Greg Behlman Jim Gilbreath Marland Blanchard Aristed Harris Rick Roif Dwayne Lowe L Bell Windsor McKnight Lewis Herbert Adams Kyle Harrison Chancellon Jackson Rod Edwards Sherman McCoy Keith Powell Latham Bell Oliver Hamilton Shaun Carr Christian Grismaud Matt Beckman George Akkann Reginald Williams Delvrick Bozeman Nate Rauh Andrew Mattson Patrick Warnecke Geoff Lowe Blake Sheffler Dan Feagans Company Square Up Bates Electric Blanchard Electric Harris Heat and Cool Superbelect Riley Heating & Cooling LB Electric I & A Contracting Landscaping Fred M. Luth + Sons The Masonry Group Rena's Cleaning & Construction Resource Electrical Systems CCIMW LB Electric Superior Construction Group Carr Flooring ABNA NOR-VZ Grading J Bathe Electric Mokan Simms KAI KAI KAI SLHA Brinkmann Constructors Brinkmann Constructors Email [email protected] [email protected] [email protected] [email protected] [email protected] [email protected] [email protected] [email protected] [email protected] [email protected] [email protected] [email protected] [email protected] [email protected] [email protected] keith@ccistl [email protected] [email protected] [email protected] [email protected] [email protected] [email protected] [email protected] [email protected] [email protected] [email protected] [email protected] [email protected] [email protected] [email protected] Phone

314-348-3880 314-713-4400 314-771-3892 314-486-7116 314-546-3082 314-209-1530 314-599-4338 314-565-7601 618-616-0094 412-4993 314-454-0222 314-291-0039 636-222-3230 314-327-8272 314-242-6800 241-8188

636-537-9700

North Sarah Phase II Pre-Bid Meeting McCormack House 10/9/12Name Cordell Sawyer Carlos Mito Kennth Hutchinson Emil Mesinoyic Leon O'Hara Fabian Harris Blake Sheffler Dan Feagans Randy Rhodes Emily Baron Delvrick Bozeman Ezra Emerson Company Sledroc Construction Ardor Fire Protection Taalke LLC St. Louis Electric Paradigm Builders Paradigm Builders Brinkmann Brinkmann MBS MBS Simms SLHA Email 314-957-8772 314-565-1518 314-616-2907 314-534-3000 314-283-6061 314-600-5939 Phone [email protected] [email protected] [email protected] [email protected] [email protected] [email protected] [email protected] [email protected]

314-286-4399

[email protected]

NORTH SARAH REDEVELOPMENT PHASE II BUILDING AND ONSITE IMPROVEMENTS

10 11029 R1

SECTION 012300 ALTERNATES PART 1 GENERAL 1.1 A. RELATED DOCUMENTS Drawings and general provisions of the Contract, including General and Supplementary Conditions and other Division 01 Specification Sections, apply to this Section. SUMMARY A. 1.3 A. Section includes administrative and procedural requirements for alternates. DEFINITIONS Alternate: An amount proposed by bidders and stated on the Bid Form for certain work defined in the bidding requirements that may be added to or deducted from the base bid amount if Owner decides to accept a corresponding change either in the amount of construction to be completed or in the products, materials, equipment, systems, or installation methods described in the Contract Documents. 1. 2. Alternates described in this Section are part of the Work only if enumerated in the Agreement. The cost or credit for each alternate is the net addition to or deduction from the Contract Sum to incorporate alternate into the Work. No other adjustments are made to the Contract Sum.

1.2

1.4 A.

PROCEDURES Coordination: Revise or adjust affected adjacent work as necessary to completely integrate work of the alternate into Project. 1. Include as part of each alternate, miscellaneous devices, accessory objects, and similar items incidental to or required for a complete installation whether or not indicated as part of alternate.

B.

Notification: Immediately following award of the Contract, notify each party involved, in writing, of the status of each alternate. Indicate if alternates have been accepted, rejected, or deferred for later consideration. Include a complete description of negotiated revisions to alternates. Execute accepted alternates under the same conditions as other work of the Contract.

C.

ALTERNATES 2012 KAI

012300 1 October 2, 2012

NORTH SARAH REDEVELOPMENT PHASE II BUILDING AND ONSITE IMPROVEMENTS

10 11029 R1

D.

Schedule: A schedule of alternates is included at the end of this Section. Specification Sections referenced in schedule contain requirements for materials necessary to achieve the work described under each alternate.

PART 2 PRODUCTS (Not Used) PART 3 EXECUTION 3.1 SCHEDULE OF ALTERNATES Note: The alternates listed below shall be presented to the Owner in an itemized per building, per unit format.

Exterior ImprovementsA. B. C. D. E. F. G. H. I. J. K. Alternate #E1: Alternate #E2: Alternate #E3: Alternate #E4: Alternate #E5: Alternate #E6: Alternate #E7: Alternate #E8: Alternate #E9: Alternate #E10: Alternate #E11: + + + + + +

(E)

Provide field painted fiber cement lap siding, aluminum soffits, and MiraTec trim in lieu of vinyl lap siding and trim. Provide field painted fiber cement vertical panels, MiraTec trim, and aluminum soffits in lieu of vinyl vertical siding and trim. Provide permeable paving for sidewalks in lieu of standard concrete for sidewalks. Provide high albedo concrete for sidewalks in lieu of standard concrete for sidewalks. Provide Energy Star compliant asphalt shingles in lieu of standard asphalt shingles. Provide asphalt shingles at all porch roofs in lieu of standing seam metal roofing. Provide aluminum windows on MU A, MU B, MU C, and MU D in lieu of vinyl windows. Provide mechanical dead bolts in lieu of electronic dead bolts at unit entry doors. Provide mechanical locksets in lieu of electrical locksets. Remove P.V. ready rough in from each building. Provide vinyl siding at side elevations of building type B and D which call for complete brick facing.

ALTERNATES 2012 KAI

012300 2 October 2, 2012

NORTH SARAH REDEVELOPMENT PHASE II BUILDING AND ONSITE IMPROVEMENTS

10 11029 R1

L.

Alternate #E12:

Provide field painted fiber cement siding at side elevations of Building Type B and D which call for complete brick facing.

Interior FinishesA. B. C. D. E. F. G. Alternate #F1: Alternate #F2: Alternate #F3: Alternate #F4: Alternate #F5: Alternate #F6: Alternate #F7: + + + + + + +

(F)Provide T&G factory finished bamboo plank flooring in lieu of specified sheet vinyl at all living, dining, and kitchens in all building types. Provide T&G factory finished bamboo plank flooring in lieu of specified sheet carpet at all bedrooms in all building types. Provide 12"x12" ceramic tile in lieu of specified sheet vinyl at all bathrooms and utility rooms in all building types. Provide kitchen sink base cabinet with fold back doors and removable toe kick and base panel in lieu of removable cabinet. Provide bathroom vanity with fold back doors and removable toe kick and base panel in lieu of removable vanity. Provide finished interior wood stair with stained solid oak treads and risers in building type B, D, and F. Provide sheet good flooring (SV 1) (Tackett Fiber Floor Footnotes Exotic Elm) in lieu of carpet throughout second floor of townhome units.

END OF SECTION 012300

ALTERNATES 2012 KAI

012300 3 October 2, 2012

INTERIOR UNIT FINISH SCHEDULEROOM NO. ROOM NAME TOWNHOME & GARDEN UNITS KITCHEN DINING ROOM LIVING ROOM COAT CLOSET PANTRY UTILITY MASTER BATH BATHROOM POWDER ROOM LINEN MASTER BEDROOM BEDROOM BEDROOM CLOSET FLOOR MATL FIN BASE MTL FIN WALL MTL FIN CEILING MTL FIN NOTES

TE ES

TYP MU FLOOR ASSEMBLY

ED

SV 1 SV 1 SV 1 SV 1 SV 1 SV 1 SV 2 SV 2 SV 2 SV 2 CPT 1 CPT 1 CPT 1

MANUF WB 1 PT 2 MANUF WB 1 PT 2 MANUF WB 1 PT 2 MANUF WB 1 PT 2 MANUF WB 1 PT 2 MANUF WB 1 PT 2 MANUF WB 1 PT 2 MANUF WB 1 PT 2 MANUF WB 1 PT 2 GYP SHALL BE INSTALLED ALL DROP MANUF WBABOVE 1 PT 2 CEILINGS AND SOFFITS NO EXCEPTIONS WB 1 PT 2 WB 1 PT 2 WB 1 PT 2

GYP PT 1 GYP PT 1 GYP PT 1 GYP PT 1 GYP PT 1 GYP PT 1 GYP PT 1 GYP PT 1 LOBBY FLOOR FRAMING PER PLAN GYP PT 1 LOBBY SPACE PER PLAN GYP PT 1 GYP PT 1 GYP PT 1 GYP PT 1

GYP GYP GYP GYP GYP GYP GYP GYP GYP GYP GYP GYP GYP

PT PT PT PT PT PT PT PT PT PT PT PT PT

1 1 1 1 1 1 1 1 1 1 1 1 1

1

1

STAIRS

CPT 1

WB 1

PT 2

GYP

PT 1

GYP

PT 1

CONT DROP CEILING (MECH SPACE)

CONT. DROP CLG @ ENTIRE CORRIDOR

1' 1" +

RECT. DUCT (HIDDEN) PER PLAN

ACCENT DROP CLG @ ALCOVE

SPIRAL DUCT PER PLAN

1

TYP UNIT ENTRY DOOR ALCOVE PER PLAN

GYP BD WALL BEYOND

7' 6" +

NOTE: THIS APPLIES TO ALL MU CORRIDORS.

SCHEDULED FLOOR

19

MU CORRIDOR CEILING DIAGRAM3/4" = 1' 0"

SK-A3-03-01 SK-A-A1-02.001

10-1102904.23.10 10.16.2012

SCHEDULES BUILDING "A"THIRD FLOOR & ROOF PLANS

NORTH SARAH PHASE 2

TE ESGYP SHALL BE INSTALLED ABOVE ALL DROP CEILINGS AND SOFFITS NO EXCEPTIONSTYP MU FLOOR ASSEMBLY

LOBBY FLOOR FRAMING PER PLAN LOBBY SPACE PER PLAN

ED

CONT DROP CEILING (MECH SPACE)

CONT. DROP CLG @ ENTIRE CORRIDOR

1' 1" +

RECT. DUCT (HIDDEN) PER PLAN

ACCENT DROP CLG @ ALCOVE

SPIRAL DUCT PER PLAN

1

TYP UNIT ENTRY DOOR ALCOVE PER PLAN

GYP BD WALL BEYOND

7' 6" +

NOTE: THIS APPLIES TO ALL MU CORRIDORS.

SCHEDULED FLOOR

19

MU CORRIDOR CEILING DIAGRAM3/4" = 1' 0"

SK-A4-04-01 SK-A-A1-02.001

10-1102904.23.10 10.16.2012

TYPICAL BUILDING "A" DETAILS THIRD FLOOR& ROOF PLANS

NORTH SARAH PHASE 2

TRANSITION UP TO REGISTER. 7" TRANSITION UP TO REGISTER.

DINING2" COMBUSTION AND VENT AIR UP.1 7" 3 125 3" 12"x6" EF 3 6" 12"x6" 3 125 3"

7"

KITCHEN4"

3 125 F 3

4"

PR

12"x10"

12"x6"

UTILITY 5W

D

12"x6" 16"x10" A 3 125 1" GAS PIPE.

615x5 R.A. UP TO SECOND FLOOR. 8"

TRANSITION UP TO REGISTER. UP

LIVING RM

TRANSITION UP TO REGISTER.

IRST FLOOR PLAN & MECHANICAL4" = 1'&0"

8

1

SK-F-M1-01-01 SK-M1-01-01

10-11029 10.16.2012

NORTH SARAH FLOOR PLANS PHASE 2 MECHANICAL

1 1

11 1 2

CU 3

CU 2

11 1 3 2 3

CU 2

11

CU 3

11

1

TRANSITION UP TO REGISTER ABOVE. 4" DINING 1" GAS PIPE DOWN 14x6 RA UP

PR EF 3

PR EF 3

TRANSITION UP TO REGISTER ABOVE. 4" DINING 1" GAS PIPE DOWN 14x6 RA UP B 8" 7" 4 150 7" 7" 4" 8" 1 3 125 TRANSITION UP TO REGISTER.

TRANS UP REGIS

4 50

3"

3"

KITCHEN2" COMBUSTI AND VENT AIR 3 125 F 3 3" 3" 1

78"

B

7

16"x10" T8"x4"

16"x10"

92" F 2DD

2" 4"

2" 4"

2" F 2

T8"x4"

7" 3 125 12"x6" 12"x10"

D

5W

5W

5KITCHEN 12"x4" TRANSITION UP TO REGISTER ABOVE. 4 175 KITCHEN 12"x4" TRANSITION UP TO REGISTER ABOVE. 4 175

UTILITYW

12"x6" 1" GAS PIPE. 3 125 A 16"x10" 3 125

615x5 R.A. UP TO SECOND FLOOR. 8"

12"x4" LIVING RM

12"x4" LIVING RM

TRAN UP REG

TRANSITION UP TO REGISTER ABOVE.

UP

UP

TRANSITION UP TO REGISTER ABOVE.

LIVING RM

TRANSITION UP TO REGISTER.

SK-M1-01-02 SK-F-M1-01-02

10-11029 10.16.2012

NORTH SARAH FLOOR PLANS PHASE 2 MECHANICAL

HEARING + VISUALLY IMPAIRED 2 BEDROOM

FINNEY AVENUE4132 4130 4128 4124 4122 4120 4116 4112 4110

HEARING + VISUALLY IMPAIRED 2 BEDROOM

1

3

3

3 30

15.8'

0.9' 2.4'

41.7'2 1 1 1

0.6'

FF=495.47

1

FF=494.94

.5. .B.

30 29 4

.6. .D.

30 29 4

.7. .B.

7 6 4 22

27 3

4

.8. . MU"A .5

1049

22 1 7

TOT LOT A

4.5'16.0'

1 5 10 27 8 9 3 9 5

18 28

5.4'

5

40.0' 3.8'

3 9

26 13 14 17 8 15 16 6 25 24 13 9 26 8 5

1 7 27 3 9 29 9 5 9 4 12 5 20 19

16 1041 5

7 26 6 8 5 27 9 19 20

.1. .A.

4 1 3014' 8 3/8"

.2. .D.

11 4 26 3 9 22 2 1 23 22 4

.3. .D.

1

4 29

.4. .B.

22 4

11

29 30

12 1 29 30 3 23

1035

1 3 21 3

8 2 1 21

12.20'

NORTH SARAH REDEVELOPMENT % PHASE 2 BUILDING AND ONSITE IMPROVEMENTS

BLOCK A UNITS = 33 PARKING = 35

12 11

14 15

NORTH SARAH STREET

20.7'

GA FF RA = G 49 E 6. 60

BLOCK 'A'

ACCESSIBLE 3 BEDROOM (UNIT A AND B)

ACCESSIBLE 2 BEDROOM (UNIT 101) 2 BEDROOM (UNIT 102)

CD BANKS AVENUE

HEARING + VISUALLY IMPAIRED 3 BEDROOM

SITE PLAN KEYED NOTES:GENERAL NOTES: A. SEE SHEET A0%01 FOR PROJECT GENERAL NOTES.

1

SITE PLAN % WEST1/16" = 1'%0"

1. LINE OF SITE SECURITY FENCING. SEE DETAIL 2/A2%01 FOR TYP. FENCE DETAIL. 2. LOCATION OF SWINGING MAN GATE AT FENCING % SEE DETAIL 1/A2%01. 3. CONCRETE SIDEWALK % TYPICAL.

B.

SEE SHEET A3%03 FOR WINDOW, DOOR, AND FINISH SCHEDULES.

5. 4" THICK CONCRETE PATIO ON GRANULAR BASE. SLOPE AWAY FROM BUILDING AT 2% MAX. % TYPICAL AT REAR UNIT ENTRY PER PLAN. TYP. PATIO SIZE 8' X 10' UNO. 6. DECORATIVE METAL BENCH ON CONCRETE PAD. 7. DECORATIVE TRASH RECEPTACLE ON CONCRETE PAD. 8. PAD MOUNTED ELECTRICAL TRANSFORMER. 9. POLE MOUNTED SITE LIGHTING% SEE SITE ELECTRICAL DWG FOR BALANCE OF INFORMATION.

D:\Users\pwarnecke\Documents\Site Plan_Central_pwarnecke.rvt

10. PEDESTAL MOUNTED USMAIL CBU. 11. VEHICULAR PARKING AREA / LOT. 12. 4" WIDE PARKING LOT STRIPING % TRAFFIC YELLOW. 13. DUMPSTER ENCLOSURE PER PLAN % SEE DETAIL 3/A2%01. 14. 8 CY. RECYCLING DUMPSTER. 15. 8 CY. REFUSE DUMPSTER. 16. CONCRETE DUMPSTER PAD AND GARABAGE TRUCK APRON. 17. BBQ AREA WITH TRELLIS STRUCTURE % SEE DETAIL 6/A2%01. 18. TOT LOT PLAY STRUCTURE WITH PROTECTIVE SURFACING. 19. ACCESIBLE PARKING SPACE WITH PAINTED WHEEL CHAIR GRAPHIC % TRAFFIC YELLOW. PROVIDE STRIPING AT SIDE OF SPACE AS INDICATED. 20. REC. POLE MOUNTED ACCESSIBLE PARKING SPACE SIGN WITH WHEEL CHAIR GRAPHIC. SURFACE MOUNTED POLE NOT ALLOWED. 21. DECORATIVE MASONRY PIER WITH CAST STONE CAP SEE DETAIL 5/A2%01. 22. PROVIDE ALTERNATE BRICK ELEVATION FOR THIS SIDE OF BUILDING INDICATED BY DASHED LINE. 23. SWINGING VEHICULAR ENTRY GATES PER PLAN. 24. BIKE RACK ON CONCRETE PAD. 25. PEDESTAL MOUNTED PARK GRILL.SHEET TITLE:

ENLARGED SITE PLAN % WEST

4. PAD MOUNTED CONDENSING UNIT.

SAINT LOUIS, MO 63113

4145

4139

4137

4135

4125

4123

4121

4117

4115

4111

4105

211 North Broadway Suite 1900 Saint Louis, MO 63102 T. 314.241.8188 F. 314.241.0125 www.kai#db.com

2.7'

MARK DATE DESCRIPTION 1 10/16/12 ADDENDUM 1

KAI PROJECT NO.

10%11029TOTAL SHEET SIZE IS 42" x 30" ISSUE DATE

10/16/2012 3:11:16 PM

26. PARKING STOP PER PLAN. 27. TELECOM PEDESTAL (CABLE TV / TELEPHONE). 28. 4 FOOT DECORATIVE METAL FENCING AT EDGE OF TOT LOT PER PLAN SEE DETAIL 2/A2%02. 29. ELECTRIC METER CENTER 30. GAS METER(S)

1

10/2/2012SHEET NO. 2012 KAI

A1"01PLAN NORTH

KEYED NOTES12" = 1'%0"

BID SET

I hereby specify, pursuant to RSMo 327.411, that this drawing sheet is authenticated by my seal. A 000391 : E 000949

55.2'

50.1' 50.1'

34.7'

50.4'

48.0'

24.3'

SITE PLAN KEYED NOTES:1. LINE OF SITE SECURITY FENCING. SEE DETAIL 2/A2!01 FOR TYP. FENCE DETAIL. 2. LOCATION OF SWINGING MAN GATE AT FENCING ! SEE DETAIL 1/A2!01. 3. CONCRETE SIDEWALK ! TYPICAL. 4. PAD MOUNTED CONDENSING UNIT. 5. 4" THICK CONCRETE PATIO ON GRANULAR BASE. SLOPE AWAY FROM BUILDING AT 2% MAX. ! TYPICAL AT REAR UNIT ENTRY PER PLAN. TYP. PATIO SIZE 8' X 10' UNO. 6. DECORATIVE METAL BENCH ON CONCRETE PAD. 7. DECORATIVE TRASH RECEPTACLE ON CONCRETE PAD. 8. PAD MOUNTED ELECTRICAL TRANSFORMER. 9. POLE MOUNTED SITE LIGHTING! SEE SITE ELECTRICAL DWG FOR BALANCE OF INFORMATION. 10. PEDESTAL MOUNTED USMAIL CBU. 11. VEHICULAR PARKING AREA / LOT. 12. 4" WIDE PARKING LOT STRIPING ! TRAFFIC YELLOW. 13. DUMPSTER ENCLOSURE PER PLAN ! SEE DETAIL 3/A2!01. 3920 3908 3906 3902 3900

FINNEY AVENUE

14. 8 CY. RECYCLING DUMPSTER. 15. 8 CY. REFUSE DUMPSTER. 16. CONCRETE DUMPSTER PAD AND GARABAGE TRUCK APRON. 17. BBQ AREA WITH TRELLIS STRUCTURE ! SEE DETAIL 6/A2!01. 18. TOT LOT PLAY STRUCTURE WITH PROTECTIVE SURFACING.

1 2 9 1 1

1

19. ACCESIBLE PARKING SPACE WITH PAINTED WHEEL CHAIR GRAPHIC ! TRAFFIC YELLOW. PROVIDE STRIPING AT SIDE OF SPACE AS INDICATED. 20. REC. POLE MOUNTED ACCESSIBLE PARKING SPACE SIGN WITH WHEEL CHAIR GRAPHIC. SURFACE MOUNTED POLE NOT ALLOWED.

21 3 23 17 25 30 29

21. DECORATIVE MASONRY PIER WITH CAST STONE CAP SEE DETAIL 5/A2!01. 22. PROVIDE ALTERNATE BRICK ELEVATION FOR THIS SIDE OF BUILDING INDICATED BY DASHED LINE. 23. SWINGING VEHICULAR ENTRY GATES PER PLAN.

30 3 9 5 6 1048

BLOCK 'B'

24. BIKE RACK ON CONCRETE PAD. 25. PEDESTAL MOUNTED PARK GRILL. 26. PARKING STOP PER PLAN. 27. TELECOM PEDESTAL (CABLE TV / TELEPHONE). 28. 4 FOOT DECORATIVE METAL FENCING AT EDGE OF TOT LOT PER PLAN SEE DETAIL 2/A2!02. 1045

.9. .F.12

26 7

. 10 . . MU B .6

29. ELECTRIC METER CENTER 30. GAS METER(S) 1

1 1046

11

7 18

KEYED NOTES12" = 1'!0"

29 1044 9 27 7 10 8 1040 5 20 26 4 1038 3 19 5 9 3 24 1041 9 8 1043 5 3

28

TOT LOT B

GENERAL NOTES: A. SEE SHEET A0!01 FOR PROJECT GENERAL NOTES. B. SEE SHEET A3!03 FOR WINDOW, DOOR, AND FINISH SCHEDULES.

NEW STREET

BLOCK B UNITS = 39 PARKING = 4023 9 9 1

16 15 11 14 13

9

21

1 2

3921

1

SITE PLAN ! EAST1/16" = 1'!0"

D:\Users\pwarnecke\Documents\Site Plan_Central_pwarnecke.rvt

ENLARGED SITE PLAN ! EAST

CD BANKS AVENUE

ACCESSIBLE 1 BEDROOM (UNIT 110) 2 BEDROOM (UNIT 203)

3903

SAINT LOUIS, MO 63113

12

1039

NORTH SARAH REDEVELOPMENT ! PHASE 2 BUILDING AND ONSITE IMPROVEMENTS

VANDEVENTER AVENUE

211 North Broadway Suite 1900 Saint Louis, MO 63102 T. 314.241.8188 F. 314.241.0125 www.kai#db.com

MARK DATE DESCRIPTION 1 10/16/12 ADDENDUM 1

SHEET TITLE:

KAI PROJECT NO.

10!11029 10/16/2012 3:11:18 PMTOTAL SHEET SIZE IS 42" x 30" ISSUE DATE

10/2/2012SHEET NO. 2012 KAI

A1 02PLAN NORTH

BID SET

I hereby specify, pursuant to RSMo 327.411, that this drawing sheet is authenticated by my seal. A(000391 : E(000949

ACCESSIBLE 1 BEDROOM (UNIT 202) 2 BEDROOM (UNIT 203)

SITE PLAN KEYED NOTES:3902 1. LINE OF SITE SECURITY FENCING. SEE DETAIL 2/A2!01 FOR TYP. FENCE DETAIL. 2. LOCATION OF SWINGING MAN GATE AT FENCING ! SEE DETAIL 1/A2!01. 3. CONCRETE SIDEWALK ! TYPICAL.

CD BANKS AVENUE

1

21

2

4. PAD MOUNTED CONDENSING UNIT. 5. 4" THICK CONCRETE PATIO ON GRANULAR BASE. SLOPE AWAY FROM BUILDING AT 2% MAX. ! TYPICAL AT REAR UNIT ENTRY PER PLAN. TYP. PATIO SIZE 8' X 10' UNO. 1 6. DECORATIVE METAL BENCH ON CONCRETE PAD. 7. DECORATIVE TRASH RECEPTACLE ON CONCRETE PAD.

23

3

28 8. PAD MOUNTED ELECTRICAL TRANSFORMER. 9 9 1023 9. POLE MOUNTED SITE LIGHTING! SEE SITE ELECTRICAL DWG FOR BALANCE OF INFORMATION. 10. PEDESTAL MOUNTED USMAIL CBU. 11. VEHICULAR PARKING AREA / LOT. 18 11 17 6 7 5 3 1019 15. 8 CY. REFUSE DUMPSTER. 16. CONCRETE DUMPSTER PAD AND GARABAGE TRUCK APRON. 17. BBQ AREA WITH TRELLIS STRUCTURE ! SEE DETAIL 6/A2!01. 18. TOT LOT PLAY STRUCTURE WITH PROTECTIVE SURFACING. 19. ACCESIBLE PARKING SPACE WITH PAINTED WHEEL CHAIR GRAPHIC ! TRAFFIC YELLOW. PROVIDE STRIPING AT SIDE OF SPACE AS INDICATED. 20. REC. POLE MOUNTED ACCESSIBLE PARKING SPACE SIGN WITH WHEEL CHAIR GRAPHIC. SURFACE MOUNTED POLE NOT ALLOWED. 21. DECORATIVE MASONRY PIER WITH CAST STONE CAP SEE DETAIL 5/A2!01. 16 15 14 9 13 9 26 27 8 2 1 29 1 23 1 30 24. BIKE RACK ON CONCRETE PAD. 25. PEDESTAL MOUNTED PARK GRILL. 26. PARKING STOP PER PLAN. 27. TELECOM PEDESTAL (CABLE TV / TELEPHONE). 28. 4 FOOT DECORATIVE METAL FENCING AT EDGE OF TOT LOT PER PLAN SEE DETAIL 2/A2!02. 29. ELECTRIC METER CENTER 30. GAS METER(S) 1 1017 22. PROVIDE ALTERNATE BRICK ELEVATION FOR THIS SIDE OF BUILDING INDICATED BY DASHED LINE. 25

12

26

TOT LOT C

. 11 . . MU C .

12. 4" WIDE PARKING LOT STRIPING ! TRAFFIC YELLOW. 13. DUMPSTER ENCLOSURE PER PLAN ! SEE DETAIL 3/A2!01. 14. 8 CY. RECYCLING DUMPSTER.

BLOCK C UNITS = 17 PARKING = 23

20 24 5 19

BLOCK 'C'

ALLEY

1 1 29

1 1 16 15 14 13 30 2 9 3

KEYED NOTES12" = 1'!0" GENERAL NOTES: A. SEE SHEET A0!01 FOR PROJECT GENERAL NOTES. B. SEE SHEET A3!03 FOR WINDOW, DOOR, AND FINISH SCHEDULES.

1011

9 5 26

BLOCK D UNITS = 14 PARKING = 135

1009

11

BLOCK 'D'

1007

5 9

1003 1 9

D:\Users\pwarnecke\Documents\Site Plan_Central_pwarnecke.rvt

23

6 7 24SHEET TITLE:

ENLARGED SITE PLAN ! EAST

12

SAINT LOUIS, MO 63113

. 12 . . MU D .

NORTH SARAH REDEVELOPMENT ! PHASE 2 BUILDING AND ONSITE IMPROVEMENTS

23. SWINGING VEHICULAR ENTRY GATES PER PLAN.

VANDEVENTER AVENUE

211 North Broadway Suite 1900 Saint Louis, MO 63102 T. 314.241.8188 F. 314.241.0125 www.kai#db.com

21

1 2

MARK DATE DESCRIPTION 1 10/16/12 ADDENDUM 1

1

SITE PLAN ! EAST1/16" = 1'!0"KAI PROJECT NO.

3903

WEST BELLE PLACE

10!11029 10/16/2012 3:11:19 PMTOTAL SHEET SIZE IS 42" x 30" ISSUE DATE

10/2/2012SHEET NO. 2012 KAI

A1 03PLAN NORTH

BID SET

I hereby specify, pursuant to RSMo 327.411, that this drawing sheet is authenticated by my seal. A(000391 : E(000949

CO

WVY DH

W

W

WY DH

S

FINNEY AVENUE

SGV GV

SCO

S

GV

E

H Y

C

5BSMALL DASHED LINE REPRESENTS BUILDING SERVICE TRENCH CONTAINING SECONDARY ELECTRIC CONDUIT, AND TELEPHONE AND CABLE TELEVISION CONDUITS, TYPICAL.

6D

3

7BC P

P

E

T TLC HP5!4 4 LC LC HPMA!16 T

E

2AC AC

E

8MU A10' W. SANITARY SEWER EASEMENT

GFI P WPCO

C

LB

LC HP2!5 LB C

LA

T

P HP4!3 HP4!5

1A

3

2D3

HP2!3 LC 1 J J

3D3

4BSW

3

HP3!3

J

J

CO

1Y DH Y

FL=482.21WV

WV

1

S

S

SWV

CONDUIT FOR CHARTER FROM PEDESTAL TO POLE TO FEED EXISTING DOWNSTREAM CUSTOMERS.

6"WATER

1

DIRECT BORE BY AT&T FROM PEDESTAL TO UNDERGROUND CONDUIT. AT&T SHALL CUT AND PROVIDE SPLICE TO FEED SITE.

CD BANKS AVENUE

CONDUIT UP EXISTING POLE FOR THREE PHASE PRIMARY CONNECTION.GV

T

60" CHAIN LINK

EXISTING OVERHEAD UTILITY LINES AND POLES TO BE REMOVED AND RELOCATED UNDERGROUND WITH NEW PAD MOUNTED SWITCH UNDER SEPARATE CONTRACT IN PUBLIC IMPROVEMENTS PACKAGE. ELECTRICAL LINETYPE LEGEND UNDERGROUND CONDUIT FOR HIGH VOLTAGE PRIMARY CONDUCTORS UNDERGROUND CONDUIT FOR SECONDARY CONDUCTORS UNDERGROUND CONDUIT WITH BRANCH CIRCUIT CONDUCTORS UNDERGROUND CONDUIT FOR CABLE TELEVISION SERVICE CONDUCTORS UNDERGROUND CONDUIT FOR TELEPHONE SERVICE CONDUCTORS UNDERGROUND CONDUIT FOR SECURITY CONDUCTORS ELECTRICAL GENERAL NOTES 1. ELECTRICAL CONTRACTOR SHALL PROVIDE AND INSTALL ALL UNDERGROUND SITE CONDUITS FOR PRIMARY AND SECONDARY UTILITY POWER, TELEPHONE, AND CABLE TELEVISION DISTRIBUTION UNLESS OTHERWISE NOTED. PROVIDE TRANSFORMER PADS AND CONDUITS PER AMEREN STANDARDS, COORDINATE ALL ROUTING AND CONNECTIONS WITH AMEREN. PRIMARY RUNS FOR 240 VOLT 1!PHASE BUILDINGS CONSIST OF (1) 3" CONDUIT. SECONDARY RUNS FOR 240 VOLT 1!PHASE BUILDINGS CONSIST OF (1) 3" CONDUIT. PRIMARY RUNS FOR 208 VOLT 3! PHASE BUILDINGS CONSIST OF (1) 4" CONDUIT. SECONDARY RUNS FOR 208 VOLT 3!PHASE BUILDINGS CONSIST OF (1) 4" CONDUIT. ALL AMEREN CONDUITS SHALL BE 36" BELOW FINISHED GRADE WITH MINIMUM 36" SWEEP ELBOWS. 2. COORDINATE LOW VOLTAGE SERVICE ENTRANCE CONDUIT/CABLE ROUTING AND CONNECTIONS WITH CABLE TELEVISION AND TELEPHONE SERVICE PROVIDERS. ROUTE LOW VOLTAGE SERVICES IN ELECTRIC SERVICE ENTRANCE TRENCHES WHENEVER POSSIBLE. ALL CONDUITS FOR TELEPHONE AND CABLE TELEVISION SERVICES SHALL BE 24" BELOW FINISHED GRADE WITH MINIMUM 24" SWEEP ELBOWS. MAINTAIN 12" CLEAR HORIZONTALLY AND VERTICALLY TO ELECTRIC SERVICE CONDUITS. 3. ROUTE (1) 2" CONDUIT FOR TELEPHONE SERVICE DISTRIBUTION CABLES CONNECTING EACH TELEPHONE PEDESTAL. ROUTE (1) 3" CONDUIT FOR CABLE TELEVISION SERVICE DISTRIBUTION CABLES CONNECTING EACH CABLE TV PEDESTAL. ROUTE CONDUITS FROM PEDESTALS TO RESPECTIVE UTILITY BOX ON EACH BUILDING. 4. COORDINATE SPECIFIC UTILITY CONNECTION POINTS, POLES AND MANHOLES WITH RESPECTIVE UTILITY. 5. COORDINATE MONITORING OF ALL SPRINKLER SYSTEM FLOW AND TAMPER SWITCHES WITH APPROVED SPRINKLER SYSTEM SHOP DRAWINGS. PROVIDE ALL CONTROL PANELS, WIRELESS COMPONENTS AND WIRING REQUIRED FOR FULLY FUNCTIONAL FIRE ALARM SYSTEM. COORDINATE REQUIREMENTS WITH LOCAL FIRE MARSHAL OR AUTHORITY HAVING JURISDICTION. 6. ALL SITE LIGHTING CIRCUITS SHALL BE #10 AWG IN 1" CONDUIT MINIMUM 24" BELOW GRADE. SITE LIGHTING CIRCUITS SHALL BE CONNECTED TO HOUSE PANEL VIA PHOTOCELL. PROVIDE (1) PHOTOCELL FOR EACH SITE LIGHTING CIRCUIT ADJACENT TO THE HOUSE LIGHTING PHOTOCELL. 7. COORDINATE CONDUITS AND TRENCHING WITH PUBLIC IMPROVEMENTS PACKAGE WORK, BEING BID SEPARATELY.E

NORTH SARAH REDEVELOPMENT ! PHASE 2 BUILDING AND ONSITE IMPROVEMENTS

1

60" CHAIN LINK

D

CONDUIT FOR CHARTER FROM POLE TO PEDESTAL TO FEED NEW CUSTOMERS.

HP2!4

T T

HP3!4

BLOCK A UNITS = 33 PARKING = 34

LA

NORTH SARAH STREET

S

ST

KEYED NOTES: 1 PROVIDE POWER FOR MOTORIZED GATE OPERATOR AND ROUGH!IN CONDUITS FOR CONTROLS. COORDINATE CONDUIT LOCATIONS FOR POWER AND CONTROLS WITH GATE INSTALLER. SURFACE MOUNT RECEPTACLE ON WOODEN LEG OF TRELLIS AT 18" ABOVE GRADE. ROUTE CONDUIT EXPOSED, TIGHT TO TRELLIS LEG UNDERGROUND TO HOUSE PANEL SHOWN. THIS BUILDING SHALL BE MADE PHOTO!VOLTAIC READY. PROVIDE A CAPPED 2" CONDUIT UP THROUGH THE ROOF. CONDUIT SHALL BE ROUTED CONCEALED WITHIN WALLS. CONDUIT SHALL EXTEND OUT OF WALL AND BE CAPPED ADJACENT TO ELECTRICAL METER CENTER FOR FUTURE DISCONNECT SWITCH AND NET METERING EQUIPMENT BY OTHERS. COORDINATE ROUGH!IN FOR FUTURE CONNECTION TO UTILITY WITH AMEREN. 1 1/2" UNDERGROUND CONDUIT MINIMUM 24" DEEP FOR SECURITY CAMERA CABLES. ROUTE CONDUIT FROM OWNERS BOX ON TOWNHOUSE BUILDING TO TELEPHONE TERMINAL BOARD IN MIXED USE BUILDING. ROUTE CONDUIT IN SHARED UTILITY TRENCH WHERE POSSIBLE.

2

SITE PLAN ! WEST ! ELECTRICAL

60" CHAIN LINK

60" CHAIN LINK

SAINT LOUIS, MO 63113

211 North Broadway Suite 1900 Saint Louis, MO 63102 T. 314.241.8188 F. 314.241.0125 www.kai#db.com

D

D:\Projects\10!11029_2012\Site Plan_mhartmann.rvt

3

GV

60" CHAIN LINKS

D

4

H Y

E

MARK DATE DESCRIPTION 10/16/12 ADDENDUM 1 1 10/XX/12

S

S

GV

CO

1

SITE PLAN ! ELECTRICAL ! WEST1" = 30'!0"KAI PROJECT NO.

SHEET TITLE:

10!11029 10/15/2012 2:07:41 PMTOTAL SHEET SIZE IS 42" x 30" ISSUE DATE

10/2/2012SHEET NO. 2012 KAI

E1 00PLAN NORTH

BID SET

I hereby specify, pursuant to RSMo 327.411, that this drawing sheet is authenticated by my seal. A(000391 : E(000949H

E

E

Y

H Y

D

S

ELECTRICAL GENERAL NOTES 1. ELECTRICAL CONTRACTOR SHALL PROVIDE AND INSTALL ALL UNDERGROUND SITE CONDUITS FOR PRIMARY AND SECONDARY UTILITY POWER, TELEPHONE, AND CABLE TELEVISION DISTRIBUTION UNLESS OTHERWISE NOTED. PROVIDE TRANSFORMER PADS AND CONDUITS PER AMEREN STANDARDS, COORDINATE ALL ROUTING AND CONNECTIONS WITH AMEREN. PRIMARY RUNS FOR 240 VOLT 1 PHASE BUILDINGS CONSIST OF (1) 3" CONDUIT. SECONDARY RUNS FOR 240 VOLT 1 PHASE BUILDINGS CONSIST OF (1) 3" CONDUIT. PRIMARY RUNS FOR 208 VOLT 3 PHASE BUILDINGS CONSIST OF (1) 4" CONDUIT. SECONDARY RUNS FOR 208 VOLT 3 PHASE BUILDINGS CONSIST OF (1) 4" CONDUIT. ALL AMEREN CONDUITS SHALL BE 36" BELOW FINISHED GRADE WITH MINIMUM 36" SWEEP ELBOWS. 2. COORDINATE LOW VOLTAGE SERVICE ENTRANCE CONDUIT/CABLE ROUTING AND CONNECTIONS WITH CABLE TELEVISION AND TELEPHONE SERVICE PROVIDERS. ROUTE LOW VOLTAGE SERVICES IN ELECTRIC SERVICE ENTRANCE TRENCHES WHENEVER POSSIBLE. ALL CONDUITS FOR TELEPHONE AND CABLE TELEVISION SERVICES SHALL BE 24" BELOW FINISHED GRADE WITH MINIMUM 24" SWEEP ELBOWS. MAINTAIN 12" CLEAR HORIZONTALLY AND VERTICALLY TO ELECTRIC SERVICE CONDUITS. 3. ROUTE (1) 2" CONDUIT FOR TELEPHONE SERVICE DISTRIBUTION CABLES CONNECTING EACH TELEPHONE PEDESTAL. ROUTE (1) 3" CONDUIT FOR CABLE TELEVISION SERVICE DISTRIBUTION CABLES CONNECTING EACH CABLE TV PEDESTAL. ROUTE CONDUITS FROM PEDESTALS TO RESPECTIVE UTILITY BOX ON EACH BUILDING. 4. COORDINATE SPECIFIC UTILITY CONNECTION POINTS, POLES AND MANHOLES WITH RESPECTIVE UTILITY. LC 5. COORDINATE MONITORING OF ALL SPRINKLER SYSTEM FLOW AND TAMPER SWITCHES WITH APPROVED SPRINKLER SYSTEM SHOP DRAWINGS. PROVIDE ALL CONTROL PANELS, WIRELESS COMPONENTS AND WIRING REQUIRED FOR FULLY FUNCTIONAL FIRE ALARM SYSTEM. COORDINATE REQUIREMENTS WITH LOCAL FIRE MARSHAL OR AUTHORITY HAVING JURISDICTION. 6. ALL SITE LIGHTING CIRCUITS SHALL BE #10 AWG IN 1" CONDUIT MINIMUM 24" BELOW GRADE. SITE LIGHTING CIRCUITS SHALL BE CONNECTED TO HOUSE PANEL VIA PHOTOCELL. PROVIDE (1) PHOTOCELL FOR EACH SITE LIGHTING CIRCUIT ADJACENT TO THE HOUSE LIGHTING PHOTOCELL. 7. COORDINATE CONDUITS AND TRENCHING WITH PUBLIC IMPROVEMENTS PACKAGE WORK, BEING BID SEPARATELY. HP9 3 HP9 5 LB CONDUIT UP EXISTING POLE FOR CABLE TELEVISION CONNECTION. KEYED NOTES: 1 PROVIDE POWER FOR MOTORIZED GATE OPERATOR AND ROUGH IN CONDUITS FOR CONTROLS. COORDINATE CONDUIT LOCATIONS FOR POWER AND CONTROLS WITH GATE INSTALLER. SURFACE MOUNT RECEPTACLE ON WOODEN LEG OF TRELLIS AT 18" ABOVE GRADE. ROUTE CONDUIT EXPOSED, TIGHT TO TRELLIS LEG UNDERGROUND TO HOUSE PANEL SHOWN. THIS BUILDING SHALL BE MADE PHOTO VOLTAIC READY. PROVIDE A CAPPED 2" CONDUIT UP THROUGH THE ROOF. CONDUIT SHALL BE ROUTED CONCEALED WITHIN WALLS. CONDUIT SHALL EXTEND OUT OF WALL AND BE CAPPED ADJACENT TO ELECTRICAL METER CENTER FOR FUTURE DISCONNECT SWITCH AND NET METERING EQUIPMENT BY OTHERS. COORDINATE ROUGH IN FOR FUTURE CONNECTION TO UTILITY WITH AMEREN. 1 1/2" UNDERGROUND CONDUIT MINIMUM 24" DEEP FOR SECURITY CAMERA CABLES. ROUTE CONDUIT FROM OWNERS BOX ON TOWNHOUSE BUILDING TO TELEPHONE TERMINAL BOARD IN MIXED USE BUILDING. ROUTE CONDUIT IN SHARED UTILITY TRENCH WHERE POSSIBLE.S S

FINNEY AVENUE

S

WV

W W

E

J LC

J

HPMB 2

HPMB GFI WP 3

1 HP9 4 HP9 6 LA

HP9 8 4 1

10MU BDIRECT BORE BY AT&T FROM PEDESTAL TO EXISTING MANHOLE IN STREET.

C

P

W

T

9FLA LB

C P T

WV W WV

BLOCK B UNITS = 38 PARKING = 41 LB

1

LC

J

JWY DH

SEE

E

16"WATER

WV

W

2

S S

3

CONDUIT UP EXISTING POLE FOR SINGLE PHASE PRIMARY CONNECTION.

CD BANKS AVENUE VANDEVENTER AVENUE

4

J

J 2 1

LB

LA HPMC 28 HPMC 26 GFI WP BLOCK C UNITS = 17 PARKING = 26

HPMC 24 HPMC 32

11MU C

NORTH SARAH REDEVELOPMENT PHASE 2 BUILDING AND ONSITE IMPROVEMENTS

LB 1

HPMC 30

LA T

C P

3 LC

JS S S

E E

T

J LC CONDUIT UP EXISTING POLE FOR THREE PHASE PRIMARY CONNECTION.GV

1 HPMD 20 LB LC

3

DIRECT BORE BY AT&T FROM PEDESTAL TO EXISTING MANHOLE IN STREET.

CONDUIT UP EXISTING POLE FOR CABLE TELEVISION CONNECTION.

12MU DHPMD 18 BLOCK D UNITS = 21 PARKING = 12

T

WV

LC LBY DH

HPMD 22

HPMD 24

SITE PLAN EAST ELECTRICAL

SAINT LOUIS, MO 63113

211 North Broadway Suite 1900 Saint Louis, MO 63102 T. 314.241.8188 F. 314.241.0125 www.kai#db.com

D:\Projects\10 11029_2012\Site Plan_mhartmann.rvt

EEGV WV W WV

E

E

16"WATER

T

W

WEST BELLE AVENUE

MARK DATE DESCRIPTION 10/16/12 1 10/XX/12 ADDENDUM 1

SE

S

1

SITE PLAN ELECTRICAL EAST1" = 30' 0"

SHEET TITLE:

J

J

KAI PROJECT NO.

10 11029 10/15/2012 2:07:44 PMTOTAL SHEET SIZE IS 42" x 30" ISSUE DATE

10/2/2012SHEET NO. 2012 KAI

E1 01PLAN NORTH

BID SET

I hereby specify, pursuant to RSMo 327.411, that this drawing sheet is authenticated by my seal. A(000391 : E(000949

z ED 20 z ED 203 F 2 X

J 3 3

ED z 20 EE EE 20 EE 20 20

z z3

ED

20

z

z

3

3

LIVING RM

LIVING RM

LIVING RM

1BR L/W103OS X 2 F M

1BR L/W102

1BR L/W101

c

M

M

M

c2

c2

c2

c2 1 KITCHEN KITCHEN KITCHEN

J

F 6 RP1-33 BATH BATH BATH

5 ED 20

M11 BEDROOM 5 5 5 . 5 BEDROOM

M1

M1BEDROOMCR DC ES

z

z

ED 20

. F FACP

X 10 L

M

g cESP-1

10 L

10

GENERAL NOTES:1. ALL GENERAL NOTES AND KEYED NOTES ARE NOT REFERENCED ON EACH SHEET. 2. SEE ELECTRICAL SITE PLAN FOR THE SERVICE EQUIPMENT LOCATION ON EACH BUILDING. INSTALL HOUSE PANEL AND ELECTRICAL, TELEPHONE AND CABLE SERVICE ENTRANCE EQUIPMENT AT THE LOCATION SHOWN. 3. APPLY FIRE STOPPING MATERIALS TO ALL CABLE AND RACEWAY PENETRATIONS OF FIRE RATED ASSEMBLIES. PERFORM FIRE STOPPING TO REESTABLISH THE ORIGINAL FIRE RESISTANCE RATING OF THE ASSEMBLY AT THE PENETRATION. 4. CABLE ROUTING SHOWN ON THIS DRAWING IS DIAGRAMMATIC. ACTUAL CABLE ROUTING SHALL BE DETERMINED IN THE FIELD AND COORDINATED WITH OTHER TRADES. 5. FRONT AND BACK DOOR EXTERIOR LIGHT FIXTURES SHALL BE CONNECTED TO HOUSE PANEL AND CONTROLLED BY A PHOTOCELL. 6. EXTEND LINE SIDE OF CIRCUIT SERVING HOUSE GFI RECEPTACLE UP TO ATTIC FOR RADON SYSTEM FAN. 7. COORDINATE ALL EXTERIOR LIGHTS, DOORBELL BUTTONS AND RECEPTACLE LOCATIONS WITH ARCHITECT IN FIELD PRIOR TO ROUGHIN. 8. LUMINAIRES SHOWN WITHOUT A SWITCHLEG TAG ARE UNSWITCHED. 9. TYPE QL FIXTURES IN STAIRS SHALL HAVE ALL LAMPS ILLUMINATED WHEN ANY OCCUPANCY SENSOR IN STAIR IS ACTIVATED. THEY SHALL CUT TO ONLY ONE LAMP WHEN UNOCCUPIED.

HPMB-41

EC 20

1

BATH

2 M

2 M

2

z M1

LOBBYJ 1 BATH KITCHEN BATH 1 KITCHEN BATH LIVING RMTS FS TS FS TS FS

ED

117gL 10 S

1BR L/W1067

BATH

WP ED

ELEV100

15

M M 2 M 2 2

OS

c

M2

M2

10 . HPMB 23/25 UH 1 X 18 OS OS F F L

g

2BR/2BA1111 7

2BR/2BA112

KITCHEN

UTILITY120RP1 7

mUE

m30

STAIR118

10 L

g

EF 2GB

4 5 15 30 F 14

ELEV. EQUIP.5 30 F

X 10 ES BEDROOM BEDROOMDC

KITCHEN

15 3

113M 5 5

BEDROOM

M

M

c2 30 LIVING RM

BEDROOM

LIVING RM

BEDROOM 18 18 ED 20 z

HPMB

PE1 15 M 17

PS2 . M UH 1 17 M 2

F

TELEPHONE PANEL 6

PE1 1/3

mUE

mUE

1BR L/W107 C:\Users\dcochran.WESINC\Documents\Building-MU-B_MEP_dcochran(Recovery)(Recovery)(Recovery)(Recovery)(Recovery)(Recovery)(Recovery)(Recovery).rvtLIVING RM

1 20 EC z

z

20 EC 1

KEYED NOTES: ELECTRICAL SERVICE ENTRANCE METERING EQUIPMENT, SERVICE RECEPTACLE AND PHOTOCELL FOR CONTROL OF BUILDING LIGHTING. FEEDER FROM METER CENTER TO LOAD CENTER INSTALLED WITHIN 1ST OR 2ND FLOOR CEILING JOIST SPACE. SEE ONE LINE DIAGRAM FOR ADDITIONAL INFORMATION. 4'X8'X3/4" SHEET OF FIRE RATED PLYWOOD FOR TELEPHONE DISTRIBUTION EQUIPMENT AND CABLE TELEVISION DISTRIBUTION EQUIPMENT. ROUTE CABLES FROM CAMERA LOCATIONS TO THIS BOARD, LEAVE 10' CABLE COIL FOR CONNECTION BY OTHERS. 2" CONDUIT WITH PULLWIRE STUBBED UP THROUGH ROOF 6" FOR FUTURE PHOTO-VOLTAIC CIRCUITS. ROUTE CONDUIT CONCEALED WITHIN WALLS, STUB OUT OF EXTERIOR WALL ADJACENT TO METER CENTER. CAP CONDUIT AT WALL AND ROOF PENETRATIONS. ALLOW FOR SPACE AT WALL PENETRATION NEAR METER CENTER FOR FUTURE PHOTO-VOLTAIC PANEL AND DISCONNECT SWITCH. 3/4" CONDUIT WITH PULL WIRE ROUTED CONCEALED WITHIN WALLS FROM CEILING OF SPRINKLER ROOM UP THRU ROOF FOR IRRIGATION CONTROLLER SENSOR. FIRE ALARM POWER SUPPLY WITH CAPACITY TO SERVE BUILDING IF ALL DWELLING UNIT STROBES ARE INSTALLED.

M15 17

14

MAINT.121

14

EC 20

cOS

X

EC 20

2

zBATH 17 14 M 14 30TS TS TS TS TS FS FS FS

c

2

zNOTE: SEE TYPICAL UNIT PLANS FOR ELECTRICAL LAYOUT IN UNITS. 3

M F 1

NORTH SARAH REDEVELOPMENT - PHASE 2 BUILDING AND ONSITE IMPROVEMENTS

BEDROOM

18

F

F

F

17

4

BATH

1BR/1BA110

BEDROOM 5

BATH 2 6

M1LIVING RM

1BR L/W108

EC 20 EC 20 z KITCHEN HPMB 23/25 BEDROOM UH 1 . KITCHEN LIVING RM

z M1

DW 16 MCMU-B 1 HP1 30 1 16 UE n 20 F F UE n

DW

STAIR116

16

. UE n

M2OS

3903 CD BANKS

n

HPMB 19/21 X 16

BATH

KITCHEN

FIRST FLOOR PLAN-ELECTRICAL

TO METER CENTER MCMU-B (TYP. FOR UNIT PANELS), SEE DWG MB-E1-05

SAINT LOUIS, MO 63113

211 North Broadway Suite 1900 Saint Louis, MO 63102 T. 314.241.8188 F. 314.241.0125 www.kai-db.com

FLUSH MOUNTED JUNCTION BOX WITH WEATHERPROOF COVER AT 12'-0"AFF FOR FUTURE RETAIL SIGNAGE. ROUTE 3/4" CONDUIT TO PANEL SERVING RESPECTIVE AREA.

c OSMC

2BR/1BA109EC 20

z ED

DC

z

MARK DATE DESCRIPTION 1 10/16/12 Addendum 1

LIVING RM

BEDROOM

BEDROOM

SHEET TITLE:

KAI PROJECT NO.

10/16/2012 1:49:09 PM

1

FIRST FLOOR PLAN - ELECTRIC3/16" = 1'-0"

10-11029TOTAL SHEET SIZE IS 42" x 30" ISSUE DATE

10/2/2012SHEET NO.

BID SET 2 0 1 2 W EB B

MB-E1-00

I hereby specify, pursuant to RSMo 327.411, that this drawing sheet is authenticated by my seal. A-000391 : E-000949

BEDROOM

BEDROOM

LIVING RM

LIVING RM

BEDROOM

LIVING RM BEDROOM BEDROOM BEDROOM

LIVING RM BEDROOM GENERAL NOTES: 1. ALL GENERAL NOTES AND KEYED NOTES ARE NOT REFERENCED ON EACH SHEET. 2. SEE ELECTRICAL SITE PLAN FOR THE SERVICE EQUIPMENT LOCATION ON EACH BUILDING. INSTALL HOUSE PANEL AND ELECTRICAL, TELEPHONE AND CABLE SERVICE ENTRANCE EQUIPMENT AT THE LOCATION SHOWN.

2BR/1BA206

M1

1BR/1BA205

2BR/2BA204

2BR/2BA202

3. APPLY FIRE STOPPING MATERIALS TO ALL CABLE AND RACEWAY PENETRATIONS OF FIRE RATED ASSEMBLIES. PERFORM FIRE STOPPING TO REESTABLISH THE ORIGINAL FIRE RESISTANCE RATING OF THE ASSEMBLY AT THE PENETRATION.

M2BATH BATH

M2

M2

KITCHEN KITCHEN BATH DW e PC X 2 OS d 2 d,e PA 2 PC e 2 d,e PA 2 1 d,e PA 2 OS d PA 2 d,e PC e 2 KITCHEN

BATH KITCHEN BATH

BATH

ROUTE (2) CAT-5E CABLES FROM EACH CAMERA ROUGH-IN LOCATION TO HEADEND LOCATION ON TELEPHONE BOARD. LEAVE 5'-0" ADDITIONAL COILED CABLE AT EACH END FOR MAKING CONNECTIONS.

5. FRONT AND BACK DOOR EXTERIOR LIGHT FIXTURES SHALL BE CONNECTED TO HOUSE PANEL AND CONTROLLED BY A PHOTOCELL. 6. EXTEND LINE SIDE OF CIRCUIT SERVING HOUSE GFI RECEPTACLE UP TO ATTIC FOR RADON SYSTEM FAN. 7. COORDINATE ALL EXTERIOR LIGHTS, DOORBELL BUTTONS AND RECEPTACLE LOCATIONS WITH ARCHITECT IN FIELD PRIOR TO ROUGH-IN. 8. LUMINAIRES SHOWN WITHOUT A SWITCHLEG TAG ARE UNSWITCHED.

e d,e PA 2 PA 2 d,e PA 2 PC 2 d,e PA d OS 30 30 e PC 2 BATH F J 1 2 2 X 1 d 2 L 2 L

MECHANICAL215

CORRIDOR200

9. TYPE QL FIXTURES IN STAIRS SHALL HAVE ALL LAMPS ILLUMINATED WHEN ANY OCCUPANCY SENSOR IN STAIR IS ACTIVATED. THEY SHALL CUT TO ONLY ONE LAMP WHEN UNOCCUPIED.

BEDROOM

BATH e PA 30 3 2 d,e KITCHEN 1 M 4 os M BATH 4 KITCHEN BATH BATH os PC 2 F 1

F

LOBBY213T i n p t c C o e 7 0 t i h r 2 g y

KEYED NOTES: 1 2 ELECTRICAL SERVICE ENTRANCE METERING EQUIPMENT, SERVICE RECEPTACLE AND PHOTOCELL FOR CONTROL OF BUILDING LIGHTING. FEEDER FROM METER CENTER TO LOAD CENTER INSTALLED WITHIN 1ST OR 2ND FLOOR CEILING JOIST SPACE. SEE ONE LINE DIAGRAM FOR ADDITIONAL INFORMATION. 4'X8'X3/4" SHEET OF FIRE RATED PLYWOOD FOR TELEPHONE DISTRIBUTION EQUIPMENT AND CABLE TELEVISION DISTRIBUTION EQUIPMENT. ROUTE CABLES FROM CAMERA LOCATIONS TO THIS BOARD, LEAVE 10' CABLE COIL FOR CONNECTION BY OTHERS. 2" CONDUIT WITH PULLWIRE STUBBED UP THROUGH ROOF 6" FOR FUTURE PHOTO-VOLTAIC CIRCUITS. ROUTE CONDUIT CONCEALED WITHIN WALLS, STUB OUT OF EXTERIOR WALL ADJACENT TO METER CENTER. CAP CONDUIT AT WALL AND ROOF PENETRATIONS. ALLOW FOR SPACE AT WALL PENETRATION NEAR METER CENTER FOR FUTURE PHOTO-VOLTAIC PANEL AND DISCONNECT SWITCH. 3/4" CONDUIT WITH PULL WIRE ROUTED CONCEALED WITHIN WALLS FROM CEILING OF SPRINKLER ROOM UP THRU ROOF FOR IRRIGATION CONTROLLER SENSOR. FIRE ALARM POWER SUPPLY WITH CAPACITY TO SERVE BUILDING IF ALL DWELLING UNIT STROBES ARE INSTALLED.

COMMUNITY ROOM214M 4

ELEV.KITCHEN

d

2 L

100

2BR/2BA207

os

ROOF ACCESS

PA d,e 2

2BR/2BA4

M2

M2

2BR/2BA201UE

F

M 3

3 X 2 2 L 4

m18

OS 30 F

LIVING RM

CIRCUITS 2 & 4, SWITCHLEG (e) IS UNSWITCHED, SWITCHLEG (d) IS CONTROLLED BY OCCUPANCY SENSOR.

PC e 4 4

M

M 4 4

M

M 4 4

M

STAIR212

1 d L 2 5

M2os PA BATH BEDROOM d,e 4 4 1 OS d BATH BATH BEDROOM PA d,e 4 5 BEDROOM M 15 F 4 M os os os os os 1

BEDROOM BEDROOM BEDROOM

BEDROOM 6 LIVING RM LIVING RM 18 18

mUE

mUE

NORTH SARAH REDEVELOPMENT - PHASE 2 BUILDING AND ONSITE IMPROVEMENTS

203

m

M2PC

NOTE: SEE TYPICAL UNIT PLANS FOR ELECTRICAL LAYOUT IN UNITS.

M2PC 4

e e 4

2BR/2BA209LIVING RM

C:\Users\dcochran.WESINC\Documents\Building-MU-B_MEP_dcochran(Recovery)(Recovery)(Recovery)(Recovery)(Recovery).rvt

2 TO METER CENTER MCMU-B (TYP. FOR UNIT PANELS), SEE DWG MB-E1-05

LIVING RM

2BR/2BA208KITCHEN

PA KITCHEN 4 d,e 1

PA BEDROOM BATH 4 BEDROOM BATH d,e OS d

DW UE 4 16

n

n

PC 16 UE F F 30 4 e KITCHENSHEET TITLE:

STAIR211

M2

BATH

nX 4

30 UE 16

n

F

EXTERIOR CAMERA ROUGH-IN LOCATION AT 15' ABOVE FINISHED FIRST FLOOR LEVEL, TYPICAL. SEE ELECTRICAL SITE PLAN.

MARK DATE DESCRIPTION 1 10/16/12 Addendum 1

2BR/1BA210LIVING RM

BEDROOM

BEDROOM

KAI PROJECT NO.

10-11029 10/15/2012 4:45:24 PM

1

SECOND FLOOR PLAN - ELECTRIC3/16" = 1'-0"

TOTAL SHEET SIZE IS 42" x 30" ISSUE DATE

10/2/2012SHEET NO.

BID SET 2 0 1 2 W EB B

OS

MB-E1-01

SECOND FLOOR PLAN-ELECTRICAL

SAINT LOUIS, MO 63113

211 North Broadway Suite 1900 Saint Louis, MO 63102 T. 314.241.8188 F. 314.241.0125 www.kai-db.com

4. CABLE ROUTING SHOWN ON THIS DRAWING IS DIAGRAMMATIC. ACTUAL CABLE ROUTING SHALL BE DETERMINED IN THE FIELD AND COORDINATED WITH OTHER TRADES.

I hereby specify, pursuant to RSMo 327.411, that this drawing sheet is authenticated by my seal. A-000391 : E-000949

BEDROOM

BEDROOM

LIVING RM

LIVING RM

BEDROOM

LIVING RM BEDROOM BEDROOM BEDROOM

LIVING RM BEDROOM

2BR/1BA306211 North Broadway Suite 1900 Saint Louis, MO 63102 T. 314.241.8188 F. 314.241.0125 www.kai-db.com

M1

1BR306

1BR305

1BR304

M2BATH BATH

M2

M2

KITCHEN KITCHEN BATH KITCHEN

BATH KITCHEN BATH

BATH

b PC X 6 OS 6 a,b PA 6 PC

b 6 a,b PA 6 5 a,b a,b PA 6 OS a PA 6 PC

b 6 a,b PA 6 a,b PA 6 a,b PA 6 PC

b 6 a,b PA a OS 30 30 b PC 6 BATH a F 5 6 X 6 5 a 6 L 6 L

BEDROOM

BATH

a

MECHANICAL315

CORRIDOR300

b PC 6

5

F

PA

30

STAIR114S L 6

F

3 6 a,b 5 M 8

os M

os BATH

LOBBY116M 8

8

KITCHEN

BATH

BATH

KITCHEN

H

KITCHEN

2BR/2BA307

os

3

ROOF ACCESS

PA a,b 6

1BR8

M2

M2

1BR301UE m 18 OS m 30 X 6 F L 6

303

F

M

PROVIDE AT TOP OF SHAFT

LIVING RM

CIRCUITS 6 & 8, SWITCHLEG (b) IS UNSWITCHED, SWITCHLEG (a) IS CONTROLLED BY OCCUPANCY SENSOR.

OS a

PC 8

M

M

M

M

M

Room312

5 a L 6

b

8

8

8

8

8 BEDROOM BEDROOM BEDROOM BEDROOM m LIVING RM 18 UE 18 UE S m

M2os PA BATH BEDROOM 8 a,b 8 5 OS a BATH BATH PA a,b 8 5 8 os M os os os M os 1

LIVING RM

NORTH SARAH REDEVELOPMENT - PHASE 2 BUILDING AND ONSITE IMPROVEMENTS

C:\Users\dcochran.WESINC\Documents\Building-MU-B_MEP_dcochran(Recovery)(Recovery)(Recovery)(Recovery)(Recovery).rvt

BEDROOM

BEDROOM

M2PC

M2PC 2 LIVING RM TO METER CENTER MCMU-B (TYP. FOR UNIT PANELS), SEE DWG MB-E1-05 b 8 8

b

NOTE: SEE TYPICAL UNIT PLANS FOR ELECTRICAL LAYOUT IN UNITS.

2BR/2BA309LIVING RM GENERAL NOTES: 1. ALL GENERAL NOTES AND KEYED NOTES ARE NOT REFERENCED ON EACH SHEET.

2BR/2BA308KITCHEN

PA KITCHEN a,b 8 5

2. SEE ELECTRICAL SITE PLAN FOR THE SERVICE EQUIPMENT LOCATION ON EACH BUILDING. INSTALL HOUSE PANEL AND ELECTRICAL, TELEPHONE AND CABLE SERVICE ENTRANCE EQUIPMENT AT THE LOCATION SHOWN. 3. APPLY FIRE STOPPING MATERIALS TO ALL CABLE AND RACEWAY PENETRATIONS OF FIRE RATED ASSEMBLIES. PERFORM FIRE STOPPING TO REESTABLISH THE ORIGINAL FIRE RESISTANCE RATING OF THE ASSEMBLY AT THE PENETRATION. 4. CABLE ROUTING SHOWN ON THIS DRAWING IS DIAGRAMMATIC. ACTUAL CABLE ROUTING SHALL BE DETERMINED IN THE FIELD AND COORDINATED WITH OTHER TRADES.

PA BEDROOM a,b 8 BEDROOM BATH OS a BATH

5. FRONT AND BACK DOOR EXTERIOR LIGHT FIXTURES SHALL BE CONNECTED TO HOUSE PANEL AND CONTROLLED BY A PHOTOCELL. 6. EXTEND LINE SIDE OF CIRCUIT SERVING HOUSE GFI RECEPTACLE UP TO ATTIC FOR RADON SYSTEM FAN.SHEET TITLE:

THIRD FLOOR PLAN-ELECTRICAL

SAINT LOUIS, MO 63113

7. COORDINATE ALL EXTERIOR LIGHTS, DOORBELL BUTTONS AND RECEPTACLE LOCATIONS WITH ARCHITECT IN FIELD PRIOR TO ROUGH-IN. 8. LUMINAIRES SHOWN WITHOUT A SWITCHLEG TAG ARE UNSWITCHED. PC UE 4 S 30 UE 16 16

n

STAIR311

n

16

UE F F 30 8

b

M2KITCHEN

9. TYPE QL FIXTURES IN STAIRS SHALL HAVE ALL LAMPS ILLUMINATED WHEN ANY OCCUPANCY SENSOR IN STAIR IS ACTIVATED. THEY SHALL CUT TO ONLY ONE LAMP WHEN UNOCCUPIED. BATH KEYED NOTES: 1 2 ELECTRICAL SERVICE ENTRANCE METERING EQUIPMENT, SERVICE RECEPTACLE AND PHOTOCELL FOR CONTROL OF BUILDING LIGHTING. FEEDER FROM METER CENTER TO LOAD CENTER INSTALLED WITHIN 1ST OR 2ND FLOOR CEILING JOIST SPACE. SEE ONE LINE DIAGRAM FOR ADDITIONAL INFORMATION. 4'X8'X3/4" SHEET OF FIRE RATED PLYWOOD FOR TELEPHONE DISTRIBUTION EQUIPMENT AND CABLE TELEVISION DISTRIBUTION EQUIPMENT. ROUTE CABLES FROM CAMERA LOCATIONS TO THIS BOARD, LEAVE 10' CABLE COIL FOR CONNECTION BY OTHERS. 2" CONDUIT WITH PULLWIRE STUBBED UP THROUGH ROOF 6" FOR FUTURE PHOTO-VOLTAIC CIRCUITS. ROUTE CONDUIT CONCEALED WITHIN WALLS, STUB OUT OF EXTERIOR WALL ADJACENT TO METER CENTER. CAP CONDUIT AT WALL AND ROOF PENETRATIONS. ALLOW FOR SPACE AT WALL PENETRATION NEAR METER CENTER FOR FUTURE PHOTO-VOLTAIC PANEL AND DISCONNECT SWITCH. 3/4" CONDUIT WITH PULL WIRE ROUTED CONCEALED WITHIN WALLS FROM CEILING OF SPRINKLER ROOM UP THRU ROOF FOR IRRIGATION CONTROLLER SENSOR. FIRE ALARM POWER SUPPLY WITH CAPACITY TO SERVE BUILDING IF ALL DWELLING UNIT STROBES ARE INSTALLED.

OS

MARK DATE DESCRIPTION 1 10/16/12 Addendum 1

n

X 8

n

F

3

4

2BR/1BA310LIVING RM

BEDROOM

BEDROOM

KAI PROJECT NO.

10-11029TOTAL SHEET SIZE IS 42" x 30" ISSUE DATE

10/15/2012 4:44:15 PM

5

6

10/2/2012SHEET NO.

BID SET 2 0 1 2 W EB B

MB-E1-021 THIRD FLOOR PLAN - ELECTRIC3/16" = 1'-0"

I hereby specify, pursuant to RSMo 327.411, that this drawing sheet is authenticated by my seal. A-000391 : E-000949

RP1 39/41 GENERAL NOTES: BANK NEMA-3R DISCONNECT SWITCHES FOR MECHANICAL EQUIPMENT ON ROOF MOUNTED UNISTRUT RACKS AS SHOWN. 1. ALL GENERAL NOTES AND KEYED NOTES ARE NOT REFERENCED ON EACH SHEET. 2. SEE ELECTRICAL SITE PLAN FOR THE SERVICE EQUIPMENT LOCATION ON EACH BUILDING. INSTALL HOUSE PANEL AND ELECTRICAL, TELEPHONE AND CABLE SERVICE ENTRANCE EQUIPMENT AT THE LOCATION SHOWN. CU 2 30A/30AF RP1 35/37 1 3. APPLY FIRE STOPPING MATERIALS TO ALL CABLE AND RACEWAY PENETRATIONS OF FIRE RATED ASSEMBLIES. PERFORM FIRE STOPPING TO REESTABLISH THE ORIGINAL FIRE RESISTANCE RATING OF THE ASSEMBLY AT THE PENETRATION. 30A/30AF 30A/30AF 30A/30AF 30A/30AF 30A/30AF 30A/30AF 30A/30AF 30A/30AF 30A/30AF 30A/30AF 4. CABLE ROUTING SHOWN ON THIS DRAWING IS DIAGRAMMATIC. ACTUAL CABLE ROUTING SHALL BE DETERMINED IN THE FIELD AND COORDINATED WITH OTHER TRADES. 5. FRONT AND BACK DOOR EXTERIOR LIGHT FIXTURES SHALL BE CONNECTED TO HOUSE PANEL AND CONTROLLED BY A PHOTOCELL. 6. EXTEND LINE SIDE OF CIRCUIT SERVING HOUSE GFI RECEPTACLE UP TO ATTIC FOR RADON SYSTEM FAN. 7. COORDINATE ALL EXTERIOR LIGHTS, DOORBELL BUTTONS AND RECEPTACLE LOCATIONS WITH ARCHITECT IN FIELD PRIOR TO ROUGH-IN. CU 1 CU 1 CU 2 CU 2 CU 2 CU 2 8. LUMINAIRES SHOWN WITHOUT A SWITCHLEG TAG ARE UNSWITCHED. 9. TYPE QL FIXTURES IN STAIRS SHALL HAVE ALL LAMPS ILLUMINATED WHEN ANY OCCUPANCY SENSOR IN STAIR IS ACTIVATED. THEY SHALL CUT TO ONLY ONE LAMP WHEN UNOCCUPIED. CU 1 CU 1 CU 2 CU 1 CU 2 CU 2 RTU 2 .

30A/30AF

30A/30AF

.

1 9 WP GFI

. CU 6

9 WP GFI

9 WP GFI

9 WP GFI

1

CU 1

CU 1

CU 1

CU 2

CU 1

CU 2

CU 1

HP1 2/4/6 3#6, #10G - 1"C. 1 2

KEYED NOTES: ELECTRICAL SERVICE ENTRANCE METERING EQUIPMENT, SERVICE RECEPTACLE AND PHOTOCELL FOR CONTROL OF BUILDING LIGHTING. FEEDER FROM METER CENTER TO LOAD CENTER INSTALLED WITHIN 1ST OR 2ND FLOOR CEILING JOIST SPACE. SEE ONE LINE DIAGRAM FOR ADDITIONAL INFORMATION. 4'X8'X3/4" SHEET OF FIRE RATED PLYWOOD FOR TELEPHONE DISTRIBUTION EQUIPMENT AND CABLE TELEVISION DISTRIBUTION EQUIPMENT. ROUTE CABLES FROM CAMERA LOCATIONS TO THIS BOARD, LEAVE 10' CABLE COIL FOR CONNECTION BY OTHERS. 2" CONDUIT WITH PULLWIRE STUBBED UP THROUGH ROOF 6" FOR FUTURE PHOTO-VOLTAIC CIRCUITS. ROUTE CONDUIT CONCEALED WITHIN WALLS, STUB OUT OF EXTERIOR WALL ADJACENT TO METER CENTER. CAP CONDUIT AT WALL AND ROOF PENETRATIONS. ALLOW FOR SPACE AT WALL PENETRATION NEAR METER CENTER FOR FUTURE PHOTO-VOLTAIC PANEL AND DISCONNECT SWITCH. 3/4" CONDUIT WITH PULL WIRE ROUTED CONCEALED WITHIN WALLS FROM CEILING OF SPRINKLER ROOM UP THRU ROOF FOR IRRIGATION CONTROLLER SENSOR. FIRE ALARM POWER SUPPLY WITH CAPACITY TO SERVE BUILDING IF ALL DWELLING UNIT STROBES ARE INSTALLED.

CU 2 3PC

4 PHOTOCELL MOUNTED ON ELEVATOR PENTHOUSE, FACING NORTH FOR CONTROL OF EXTERIOR LIGHTING CIRCUIT. 9 WP GFI 30A/30AF 30A/30AF 30A/30AF CU 2 NOTE: CONDENSING UNITS AND DISCONNECT SWITCHES SHOWN WITHOUT WIRING ARE CONNECTED TO TENANT DWELLING UNIT LOAD CENTERS, SEE E5- SERIES SHEETS FOR UNIT TYPE PLANS. 5 1 6

1

C:\Users\dcochran.WESINC\Documents\Building-MU-B_MEP_dcochran(Recovery)(Recovery)(Recovery)(Recovery)(Recovery)(Recovery).rvt

5 CU 1 1

30A/30AF 30A/30AF 30A/30AF CU 2

30A/30AF CU 1 30A/30AF 30A/30AF CU 2

CU 1

ROOF PLAN - ELECTRICAL

CU 2

CU 2

SAINT LOUIS, MO 63113

CU 2

NORTH SARAH REDEVELOPMENT - PHASE 2 BUILDING AND ONSITE IMPROVEMENTS

211 North Broadway Suite 1900 Saint Louis, MO 63102 T. 314.241.8188 F. 314.241.0125 www.kai-db.com

CU 6

CU 2 30A/30AF 30A/30AF

30A/30AF

30A/30AF

30A/30AF

30A/30AF

30A/30AF

30A/30AF

30A/30AF

30A/30AF

30A/30AF

CU 2 4 1 HPMB-9 WP 9 GFI . 30A/30AF 30A/30AF 30A/30AF 1

MARK DATE DESCRIPTION 1 10/16/12 Addendum 1

CU 2

CU 2

SHEET TITLE:

KAI PROJECT NO.

10-11029 10/16/2012 1:18:02 PMTOTAL SHEET SIZE IS 42" x 30" ISSUE DATE

10/2/2012SHEET NO.

BID SET 2 0 1 2 W EB B

1

ROOF PLAN - ELECTRICAL3/16" = 1'-0"

MB-E1-03

I hereby specify, pursuant to RSMo 327.411, that this drawing sheet is authenticated by my seal. A-000391 : E-000949

Panel: HP1Location: Supply From: Mounting: Surface Enclosure: NEMA 3R Volts: 120/208 Phases: 3 Wires: 4 A.I.C. Rating: 22,000 Mains Type: MLO Mains Rating: 400 A MCB Rating:

Panel: HPMBLocation: Supply From: Mounting: Enclosure:UTILITY 120 HP1 Surface NEMA 1

Volts: 120/208 Phases: 3 Wires: 4

A.I.C. Rating: 22,000 Mains Type: MLO Mains Rating: 100 A MCB Rating:

LOAD CENTER - M1LW VOLTAGE - 120/208, 1 PH, 3 W + G 100A BUS, 100A MLO LOAD BREAKER AMP CONDENSING UNIT 30 POLES 2 1 3 FURNACE ELECTRIC WATER HEATER 15 30 1 2 5 7 9 DRYER 30 2 11 13 WASHER LIGHTING 20 15 *AF 1 1 1 1 1 15 17 19 21 23 CIRCUIT 1 PHASE CIRCUIT X Y 2 4 6 8 10 12 14 16 18 20 22 24 1 1 1 1 20 *AF 20 *AF 15 *AF 20 *AF BREAKER POLES 1 1 1 1 1 2 AMP 20 20 20 15 15 50

FLUSH MOUNTED 10,000 AIC RATING

LOAD

KITCHEN COUNTERTOP KITCHEN COUNTERTOP DISHWASHER / DISPOSAL REFRIGERATOR RANGE HOOD RANGE

CKT 1 3 5 7 9 11 13 15 17

Circuit DescriptionPE1

Trip60 A

Poles1584 3 8316

A4924 1680 0 VA 5991 0 VA 0 VA 0 VA 14824 VA 125 A

B4924 2081

C

Poles3 4924 -------

Trip60 A ------RTU-2

Circuit Description

HPMB

100 A

3

0 VA 6590 0 VA

PS2 - Elevator Power Module

175 A

3

0 VA 0 VA 0 VA 13595 VA 115 A

Space Space Space Unusable Space Unusable Space Unusable Space

CKT 2 4 6 8 10 12 14 16 18

Total Load: Total Amps: Load Classification HVAC Lighting Power

12595 VA 105 A

Connected Load 23771 VA 9146 VA 7596 VA

Demand Factor 100.00% 100.00% 100.00%

Estimated Demand 23771 VA 9146 VA 7596 VA

Panel Totals Total Conn. Load: Total Est. Demand: Total Conn. Current: Total Est. Demand Current:40513 VA 40513 VA 112 A 112 A

Notes:

FACP

20 A 1 Total Load: Total Amps:

8316 VA 70 A

5991 VA 50 A

500 VA 6590 VA 56 A

LOAD CENTER - M1 VOLTAGE - 120/208, 1 PH, 3 W + G 100A BUS, 100A MLO LOAD BREAKER AMP CONDENSING UNIT 30 POLES 2 1 3 FURNACE ELECTRIC WATER HEATER 15 30 1 2 5 7 9 CIRCUIT 1 PHASE CIRCUIT X Y 2 4 6 8 10 12 14 16 18 20 22 24 1 1 1 15 *AF 20 *AF 20 *AF BREAKER POLES 1 1 1 1 1 2 AMP 20 20 20 15 15 50

FLUSH MOUNTED 10,000 AIC RATING

Load Classification HVAC Lighting Power

Connected Load 6000 VA 8997 VA 5400 VA

Demand Factor 100.00% 100.00% 100.00%

Estimated Demand 6000 VA 8997 VA 5400 VA

Panel Totals Total Conn. Load: Total Est. Demand: Total Conn. Current: Total Est. Demand Current:20397 VA 20397 VA 57 A 57 A

LOAD

KITCHEN COUNTERTOP KITCHEN COUNTERTOP DISHWASHER / DISPOSAL REFRIGERATOR RANGE HOOD RANGE

Notes:

DRYER

30

2

11 13

WASHER LIGHTING

20 15 *AF

1 1 1 1 1

15 17 19 21 23

BEDROOM LIVING ROOM SPARE SPACE SPACE

HALL / DOORBELL / SECURITY 15 *AF SMOKE / CO DETECTORS 15 *AF 20

Panel: PE1Location: Supply From: Mounting: Enclosure:ELEV. EQUIP. 113 HP1 Surface NEMA 1

Panel: RP1Volts: 120/208 Phases: 3 Wires: 4 A.I.C. Rating: 22,000 Mains Type: MLO Mains Rating: 60 A MCB Rating: Location: Supply From: Mounting: Surface Enclosure: NEMA 1 Volts: 120/208 Phases: 3 Wires: 4 A.I.C. Rating: 22,000 Mains Type: MLO Mains Rating: 225 A MCB Rating:

MASTER BATHROOM NOTES: *AF = ARC FAULT BREAKER

CKT 1 3 5 7 9 11 13 15 17

Circuit DescriptionUH-1 Elevator Equip. Room Light/Recept - Elevator Equip. Room

Trip20 A 20 A

Poles2 1 1500

A84 VA 1500

B180 VA

C

425 VA

1656

Poles 1 1 1

Trip 20 A 20 A 20 A

Circuit Description Lighting - Elevator Recept. - Elevator Power

CKT 2 4 6 8 10 12 14 16 18

Total Load: Total Amps: Load Classification HVAC Lighting Power

1584 VA 13 A

1680 VA 14 A

2081 VA 17 A

Connected Load 3000 VA 149 VA 2196 VA

Demand Factor 100.00% 100.00% 100.00%

Estimated Demand 3000 VA 149 VA 2196 VA

Panel Totals Total Conn. Load: Total Est. Demand: Total Conn. Current: Total Est. Demand Current:5345 VA 5345 VA 15 A 15 A

C:\Users\dcochran.WESINC\Documents\Building-MU-B_MEP_dcochran(Recovery)(Recovery)(Recovery)(Recovery)(Recovery)(Recovery)(Recovery).rvt

Notes:

CKT 1 3 5 7 9 11 13 15 17 19 21 23 25 27 29 31 33 35 37 39 41

Circuit Description Recept - Retail Space Recept - Retail Space Recept - Retail Space Recept - Retail Space Utility Space Spare Spare . Space

Trip 20 A 20 A 20 A 20 A 20 A 20 A --

Poles A 1 1080 801 VA 1 1 1 540 VA 0 VA 1 1 -0 VA 0 VA

B1080 0 VA

C

900 VA 0 VA 0 VA 0 VA

0 VA

0 VA

Poles 1 1 1 1 1 1 --

Trip 20 A 20 A 20 A 20 A 20 A 20 A --

Circuit Description Lighting - Retail Space Spare Spare Spare Spare Spare . Space

HVAC - Furnace CU-6 - Roof CU-6 -Roof

20 A 20 A 20 A

1 2 2 5375 VA 45 A 2954

1176 2954 2954 5210 VA 43 A 2954 6807 VA 57 A

CKT 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42

LOAD CENTER - M2 VOLTAGE - 120/208, 1 PH, 3 W + G 100A BUS, 100A MLO LOAD BREAKER AMP CONDENSING UNIT 30 POLES 2 1 3 FURNACE ELECTRIC WATER HEATER 15 30 1 2 5 7 9 DRYER 30 2 11 13 WASHER LIGHTING 20 15 *AF 1 1 1 1 1 15 17 19 21 23 CIRCUIT 1 PHASE CIRCUIT X Y 2 4 6 8 10 12 14 16 18 20 22 24 1 1 1 1 1 20 *AF 20 *AF 15 *AF 15 *AF 20 BREAKER POLES 1 1 1 1 1 2 AMP 20 20 20 15 15 50

FLUSH MOUNTED 10,000 AIC RATING

LOAD

KITCHEN COUNTERTOP KITCHEN COUNTERTOP DISHWASHER / DISPOSAL REFRIGERATOR RANGE HOOD RANGE

DINING ROOM LIVING ROOM BEDROOM 1 BEDROOM 2 BATHROOM

HALL / DOORBELL / SECURITY 15 *AF SMOKE / CO DETECTORS MASTER BATHROOM NOTES: 15 *AF 20

Total Load: Total Amps: Load Classification HVAC Lighting Power

NORTH SARAH REDEVELOPMENT - PHASE 2 BUILDING AND ONSITE IMPROVEMENTS

Connected Load 12990 VA 801 VA 3600 VA

Demand Factor 100.00% 100.00% 100.00%

Estimated Demand 12990 VA 801 VA 3600 VA

Panel Totals Total Conn. Load: Total Est. Demand: Total Conn. Current: Total Est. Demand Current:17391 VA 17391 VA 48 A 48 A

*AF = ARC FAULT BREAKER

RTU-2 3 #6 CU., #10 CU. G, 1"C.

NON-FUSED SWITCH PROVIDED WITH UNIT

Notes:

4 #3 CU., #8 CU. G, 1 1/4" C.

4 #3/0 CU., #6 CU., G., 2"C. 3 #3/0 CU., #6 CU., G., 2"C. BUSSMANN PS2 POWER MODULE WITH FUSES SIZED PER ELEV. MANUFACT. & SHUNT TRIP 1 ELEVATOR CONTROLLER BY OTHERS ELEVATOR MOTOR BY OTHERS 1 M1 M2 M2 M2 M2 M2 M2 M2 M2 M2

HPMB 100A 3P4W MLO

HP1 400A MLO W100A 3PCB FOR HPMB

RP1 RETAIL PANEL 200A MLO

PE1 PANEL 60A MLO

M1

M2

M2

M2

M2

M2

M2

M2

M2

M2

M1LW 4 #3/0 CU., #6 CU., G., 2"C. 4 #6 CU., #10 CU., G., 1"C.

M1LW

M1LW

M1LW

M1LW

M1LW

M1

M2

M2

M2

4 #500kcmil., #3 CU., G., 4" PVC C.

4 #3/0 CU., #6 CU., G., 2" C.

ELECTRICAL DETAILS

SAINT LOUIS, MO 63113

211 North Broadway Suite 1900 Saint Louis, MO 63102 T. 314.241.8188 F. 314.241.0125 www.kai-db.com

CKT 1 3 5 7 9 11 13 15 17 19 21 23 25 27 29 31 33 35 37 39 41

Circuit Description Recept - Second Floor CorridorRecept - Third Floor Corridor Recept - Roof convenience outlets

Trip 20 A20 A 20 A

Poles 11

A1440 1643

B1110 1440 1110 1080 989 VA

C

1838

1 325 VA

Poles 1 1 1 1 11 1 1 1

Trip 20 A 20 A 20 A 20 A 20 A20 A 20 A 20 A 20 A

Circuit Description Lighting - Second Floor Corridor Lighting - Second Floor Corridor, Community Rms Lighting - Third Floor Corridor Lighting - Third Floor Corridor, Community Rms Lighting - First Floor LobbyLighting - Maint./Utility Lighting - North Stairwell 116 Lighting - South Stairwell 118 Lighting - Exterior

Recept - Maint./Utility Recept - Maint. UH-1 North Stairwell 116 UH-1 South Stairwell 118

20 A 20 A 20 A 20 A

1 1 2 2 1500 798 VA

720 VA 592 VA 720 VA 592 VA 1500 1500 1500

CKT 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42

DINING ROOM LIVING ROOM BEDROOM 1 WORK ROOM SPACE

HALL / DOORBELL / SECURITY 15 *AF SMOKE / CO DETECTORS MASTER BATHROOM NOTES: *AF = ARC FAULT BREAKER 15 *AF 20

SINGLE PHASE METER SECTION

3 PHASE METER SECTION

3 #2, 1 #6G. ALUMINUM SER CABLE

3 #2, 1 #6G. ALUMINUM SER CABLE

3 #2, 1 #6G. ALUMINUM SER CABLE

3 #2, 1 #6G. ALUMINUM SER CABLE

3 #2, 1 #6G. ALUMINUM SER CABLE

3 #2, 1 #6G. ALUMINUM SER CABLE

3 #2, 1 #6G. ALUMINUM SER CABLE

3 #2, 1 #6G. ALUMINUM SER CABLE

3 #2, 1 #6G. ALUMINUM SER CABLE

3 #2, 1 #6G. ALUMINUM SER CABLE

3 #2, 1 #6G. ALUMINUM SER CABLE

3 #2, 1 #6G. ALUMINUM SER CABLE

3 #2, 1 #6G. ALUMINUM SER CABLE

3 #2, 1 #6G. ALUMINUM SER CABLE

3 #2, 1 #6G. ALUMINUM SER CABLE

3 #2, 1 #6G. ALUMINUM SER CABLE

3 #2, 1 #6G. ALUMINUM SER CABLE

3 #2, 1 #6G. ALUMINUM SER CABLE

3 #2, 1 #6G. ALUMINUM SER CABLE

3 #2, 1 #6G. ALUMINUM SER CABLE

3 #2, 1 #6G. ALUMINUM SER CABLE

3 #2, 1 #6G. ALUMINUM SER CABLE

3 #2, 1 #6G. ALUMINUM SER CABLE

3 #2, 1 #6G. ALUMINUM SER CABLE

3 #2, 1 #6G. ALUMINUM SER CABLE

3 #2, 1 #6G. ALUMINUM SER CABLE

3 #2, 1 #6G. ALUMINUM SER CABLE

3 #2, 1 #6G. ALUMINUM SER CABLE

3 #2, 1 #6G. ALUMINUM SER CABLE

3 #2, 1 #6G. ALUMINUM SER CABLE

MAIN DEVICE SECTION 120/208V, 3PH, 4W

MARK DATE DESCRIPTION 1 10/16/12 Addendum 1

400A 3P 800A 3P

200A 3P

100A 2P

100A 2P

100A 2P

100A 2P

100A 2P

100A 2P

100A 2P

100A 2P

100A 2P

100A 2P

100A 2P

100A 2P

100A 2P

100A 2P

100A 2P

100A 2P

100A 2P

100A 2P

100A 2P

100A 2P

100A 2P

100A 2P

100A 2P

100A 2P

100A 2P

100A 2P

100A 2P

100A 2P

100A 2P

100A 2P

M

M

M

M

M

M

M

M

M

M

M

M

M

M

M

M

M

M

M

M

M

M

M

M

M

M

M

M

M

M

M

M

N G

SHEET TITLE:

10/16/2012 1:27:31 PM

(2) SETS OF 4#500kcmil & 1#1/0 G. CU CONDUCTORS, 3-1/2"C.

METER CENTER MCMU-B 120/208V, THREE PHASE, 4 WIRE NEMA-3R, SE RATED, 65,000 AIC RATING

SUPPLEMENTAL GROUNDING ELECTRODE CONDUCTOR

KAI PROJECT NO.

#3/0

#3/0

10-11029TOTAL SHEET SIZE IS 42" x 30"

GROUNDING ELECTRODE CONDUCTOR SCHEDULE 40 PVC CONDUIT ROUTED UNDERGROUND TO UTILITY TRANSFORMER OR PEDESTAL. SEE SITE PLAN. CONDUIT ELBOWS SHALL HAVE A 36" RADIUS.

ISSUE DATE

10/2/2012SHEET NO.

1

ONE LINE DIAGRAMNOT TO SCALE

GROUND ROD (SUPPLEMENTAL GROUNDING ELECTRODE)

MB-E1-05

2 0 1 2 W EB B

UNDERGROUND METALLIC WATER PIPE (GROUNDING ELECTRODE)

BID SET

I hereby specify, pursuant to RSMo 327.411, that this drawing sheet is authenticated by my seal. A-000391 : E-000949

GENERAL NOTES:1. THESE DRAWINGS ARE DIAGRAMMATIC IN NATURE, ALL WORK IS TO BE COORDINATED BETWEEN ALL TRADES BEFORE CONSTRUCTION. 2 3 2 1 1 2 4" 2. ALL DUCTWORK, EQUIPMENT AND PIPING IS TO BE INSTALLED IN ACCORDANCE WITH ALL PERTINENT CODES. 3. DUCT SIZES SHOWN ARE SHEETMETAL SIZES. 4. CONTRACTOR SHALL COORDINATE CONDENSING UNITS ON THE ROOF WITH GENERAL CONTRACTOR. 5. CONTRACTOR HAS THE OPTION TO RUN ROUND DUCT IN LIEU OF RECTANGULAR DUCT AT NO ADDITIONAL COST. SIZES OF ROUND DUCT SHALL HAVE SIMILAR FREE AREAS. 6. ALL EXTERIOR EXHAUST AND/OR INTAKE WALL VENT CAPS SHALL BE FIELD PAINTED, COLOR SHALL BE PER ARCHITECT. 7. CLOTHES WASHER TO BE ON THE LEFT, AND DRYER TO BE ON THE RIGHT REGARDLESS WHETHER UNIT CONFIGURATION IS MIRRORED.

4"

1BR L/W3" COMUSTION AND VENT AIR BELOW FLOOR ASSEMBLY OF 2ND FLOOR 11 100 11 100 14"

4"

1BR L/W4" 4" 4"

1BR L/W11 100 11 100 14" 11 100 4" 14" 11 100

103

102

101

MECHANICAL KEYED NOTES:

1053 100 14" 4" 11 100 7" 7" 11 100 14" 3 100 3 100 14" 4" 11 100 3 7" 4"

1

4" RIGID MINIMUM 26 GAUGE DRYER VENT ABOVE CEILING. PROVIDE AND INSTALL FLUSH MOUNTED BRICK VENT WITH BACKDRAFT DAMPER, FINISHED TO MATCH BRICK. PROVIDE FIRE CAULK SEALANT AT CEILING PENETRATION. 4" RIGID MINIMUM 26 GAUGE EXHAUST VENT ABOVE CEILING. PROVIDE AND INSTALL FLUSH MOUNTED BRICK VENT WITH BACKDRAFT DAMPER, FINISHED TO MATCH BRICK. PROVIDE FIRE CAULK SEALANT AT CEILING PENETRATION. 7" RIGID MINIMUM 26 GAUGE KITCHEN EXHAUST VENT ABOVE CEILING. PROVIDE AND INSTALL FLUSH MOUNTED BRICK VENT FINISHED TO MATCH BRICK. PROVIDE FIRE CAULK SEALANT AT CEILING PENETRATION. CONDENSATE DRAIN PIPING FOR AC-1 ROUTE 3/4" CONDENSATE DRAIN PIPE TO TERMINATE INTO FLOOR DRAIN IN FIRE SERVICE ROOM. PROVIDE DRYER BOX SIMILAR TO DRYERBOX MODEL 425. INSTALL PER MFRS RECOMMENDATIONS. ROUTE 4" RIGID 26 GUAGE METAL DUCT ABOVE CEILING AS INDICATED, PROVIDE FIRE CAULK SEALANT AT CEILING PENETRATION. RTU-4 SHALL BE CONTROLLED BY TWO T-STATS, ONE ON THE FIRST FLOOR OF THE STAIRS AND ON THE THIRD FLOOR CORRIDOR, USE THE AVERAGE TEMPETURE BEWTEEN THE STATS AS THE SET POINT. PROVIDE AND INSTALL A CLEAR TAMPERPROOF VENTILATED LOCKBOX ON THE THERMOSTAT. BOTTOM OF RETURN AIR GRILLE MOUNTED APPROXIMATELY 7'-6' ABOVE FINISHED FLOOR. MOUNT UNIT IN A VERTICAL ORIENATION ON SHELF ABOVE WATER HEATER. PROVIDE DRAIN PAN UNDER UNIT WITH OVERFLOW CUT-OFF SWITCH IN PAN. CONNECT RETURN AIR DUCT TO SIDE OF UNIT AND EXTEND UP. LOCATE RETURN AIR GRILLES IN DUCT AND WALL AS INDICATED. EXTEND AND CONNECT 3/4" GAS LINE FROM GAS METER TO THE FURNACE. PROVIDE A TRAPPED CONDENSATE DRAIN LIN FROM FURNACE AND ROUTE OPEN ENDED TO FLOOR DRAIN. EXTEND BOTH A 3" EXHAUST AND 3" COMBUSTION AIR PIPE FORM FURNACE UP THROUGH CHASE AND ATTIC AND TERMINATE WITH CONCENTRIC VENT PIPE A MINIMUM OF 12" ABOVE ROOF.OFFSET BOTH VENT SETS SUCH THAT TERMINATION OF VENTS ARE AWAY FROM THE MIDDLE OF THE BUILDING. ROUTE 3/4" GAS LINE FROM GAS METER TO FURNACE. PROVIDE ALL ACCESSORIES SUCH AS SHUT-OFF VALVES THAT ARE REQUIRED. 36 GAS METERS REQUIRED FOR THIS BUILDING. COORDIATE EXACT METER LOCATIONS WITH G.C. AND GAS COMPANY BEFORE INSTALLATION OF ANY GAS PIPING. FURNACE COMBUSTION AIR AND EXHAUST AIR ROUTED UP INSIDE CORRIDOR WALLTO TO OFFSET AND CONNECT TO CONCENTRICA VENT THRU ROOF. PROVIDE REFRIGERANT PIPING ROUGH IN, & ELECTRICAL WORK PADS FOR FUTURE CONDENSING UNIT. SUPPLY AIR UP TO FLOOR ABOVE. PROVIDE 1" DUCT LINING. SIZES ARE OUTSIDE DIMENSIONS AND INCLUDE 1" DUCT LINING. 22"X16' RETURN AIR UP TO FLOOR ABOVE. PROVIDE RETURN AIR GRILLE 18' AFF. PROVIDE FIRE DAMPER AT FLOOR.

2 3D

1 T 8"x4" 8"x4" 1 50 LOCKABLE VENTED T-STAT COVER 4" T F 6 1 9 8"x4" EF 1 8 EF 2 F 1 18"x10" 1 1 40 5 4" 11 12"x18" 10"x18" 8"x4" 8" 3 110 B 7 7 4" D D 3 110 B 12"x18" 10"x18"

T 8"x4"

1 50

1 50 8"x4" 4"

T

9 14" 8"x4" 8"x4"

9

8"x4"

1

3 110 B 12"x18" 1 10"x18" T WH ABOVE WASHER/DRYER 7 1

1

4 5 6

11 8"x4"

EF 1 EF 1 EF 2 EF 2

11 1 40 F 1 8 5 10"x18" 4"

4"

2 4" 4" 8"x4" 3 100 1 50 11 8"x4" 8"x4" 4"

EF 1

1

EF 2

1 40

7"

11 100

1 4" 5 WH ABOVE WASHER/ DRYER EF 1 1 7 A 7" 11 1 7" 11 EF 1 1 50

14"

4"T i n p t c C o e 7 0 t i h r 2 g y

LOBBY11714 G

10"

1 40

WH ABOVE WASHER/DRYER

4"

WH ABOVE WASHER/DRYER

F 1 5

8

T-STAT SERVING RTU-2 11 120

11 120

7 8

2BR/2BA111EF 2 11 100 8" 1 50 8"x4" 8"x4"

4" 7 A

1

2BR/2BA112EF 2 11 100 1 50 8"x4"

ELEV100

11 120

11 100

11 100

14" T

9

D 3 110 F 1

10"x18" 8 4" 1 50

8"x4"

9

11 100

9

11 100

915 UH 1 UP 12" 11 120

8"

10 11

1BR L/W1064" 1 4" 1 3 1 4" 4" 4" 4" EF 2 7" 7" 7" 7"

10" 12 150

F 2

8

11 100

14"

11 100

5 T

12 150 4"

10"

F 2

8

11 100

14"

11 100 T

5

4"

STAIR118

11 120

12 13

WH BELOW FURNACE

4"

3 125

WH BELOW FURNACE 1

3 125T C o n p t c i e r 2 g 0 i y h t 7

D 4"

D

14D

1BR L/W107D 11 100 14" 11 100 T 14" 8" 3 110 9 18"x12" 10"x18"

UTILITY120

ELEV. EQUIP.1137"

D 4"

15

NORTH SARAH REDEVELOPMENT - PHASE 2 BUILDING AND ONSITE IMPROVEMENTS

8"

4"

4"

12"x6"

12"x6"

10"

4" 5 8"x4" 18"x12" 11 1 50 4" 4" 2 1 4" EF 1 4" 4" 4" 1 40 8"x4" 9 14" 8"x4" 8"x4" 11 5 T 14" D 12"x18" 11 100 8" EF 2 11 EF 2 1 50 8 1 4" EF 1 8"x4" F 1 1 40 8 5 WH ABOVE WASH/DRYER 11 100 8"x4"

UH 1 2

3

2

1 2 3

2

1

2

MAINT.1211

3 100

1

4"

4" 1

EF 2

1

4" 2 1 4"

4"

8"x4" 10"

12"x6" 3 125 F 1

11 100

14"

3 100

8

D

WH BELOW FURNACE 14" 4"

14" 9 11 100 14"

T

C:\Users\rlowery.WESINC\Documents\Building-MU-B_MEP_rlowery.rvt

11 100

1 10"x18"

11 100

1BR/1BA11011 100

1BR L/W108

3 110

WH ABOVE WASH/DRYER 7"

11 100

1 1 3" 3 7" UP UH 1 EF 2 4" 5 1 60 1 60 DW 1 80 7" 7" 3

STAIR116

8"x4"

9 F 2

MARK DATE DESCRIPTION 1 10/16/12 Addendum 1

8 12"x10" 12 175 12"x6"

4"

1

10"x8" 4" 12"x6"

12 175

D 500 12"x8"

D 500 7 12"x6" A

2BR/1BA109

12"x8"

STACKED GAS METERS TOTAL OF 38 METERS

3 125

D 0

D 0 3 125

T

4"

SHEET TITLE:

3

KAI PROJECT NO.

10-11029 10/16/2012 11:37:36 AMTOTAL SHEET SIZE IS 42" x 30"

4"

ISSUE DATE

10/2/2012SHEET NO.

BID SET 2 0 1 2 W EB B

7"

1

2

MB-M1-01

1

FIRST FLOOR PLAN - MECHANICAL3/16" = 1'-0"

MECHANICAL - FIRST FLOOR PLAN

1 50

F 1

SAINT LOUIS, MO 63113

211 North Broadway Suite 1900 Saint Louis, MO 63102 T. 314.241.8188 F. 314.241.0125 www.kai-db.com

RETAIL SALES AREA

4"

I hereby specify, pursuant to RSMo 327.411, that this drawing sheet is authenticated by my seal. A-000391 : E-000949

T p c o i C n t e 7 0 t h 2 g i y r

T i n p t c C o e 7 0 t i h r 2 g y

2.

3.

3.

3.

1.

2.

1.

2.

2.

GENERAL NOTES:1. THESE DRAWINGS ARE DIAGRAMMATIC IN NATURE, ALL WORK IS TO BE COORDINATED BETWEEN ALL TRADES BEFORE CONSTRUCTION. D 4" 7" 4" D 1 D 7" D

2BR/2BA4"

2. ALL DUCTWORK, EQUIPMENT AND PIPING IS TO BE INSTALLED IN ACCORDANCE WITH ALL PERTINENT CODES. 3. DUCT SIZES SHOWN ARE SHEETMETAL SIZES.

2044"

D 4" 1 7"

2BR/2BA202T 12"x6" F 2 11 100 11 100 5 4" 1.

1BR/1BA 2BR/1BA2063 125 D 0 D 0 3 125 T 10" 7 12"x6" 12"x6" A D 500 D 500 8"x4" 12 175 11 100 14" 11 100 9

205T F 1

3 125 12"x6" 8

WH BELOW FURNACE 12 150 10" F 2 11 100 11 100

T

3 125 WH BELOW FURNACE 10" 8

3 125

4. CONTRACTOR SHALL COORDINATE CONDENSING UNITS ON THE ROOF WITH GENERAL CONTRACTOR. 5. CONTRACTOR HAS THE OPTION TO RUN ROUND DUCT IN LIEU OF RECTANGULAR DUCT AT NO ADDITIONAL COST. SIZES OF ROUND DUCT SHALL HAVE SIMILAR FREE AREAS. 6. ALL EXTERIOR EXHAUST AND/OR INTAKE WALL VENT CAPS SHALL BE FIELD PAINTED, COLOR SHALL BE PER ARCHITECT. 7. CLOTHES WASHER TO BE ON THE LEFT, AND DRYER TO BE ON THE RIGHT REGARDLESS WHETHER UNIT CONFIGURATION IS MIRRORED. 8"x4"

4"

8

14"

12 150

5

11 100 WH BELOW FURNACE

14" 1 50

5 1 50 EF 2 EF 1 9 A 11 100 11 100

8"x4"

11 100 7" 12 175

8"

1 50 1 50

12"x10"

9

14" 11 100 A 11 100

8" 1 50

4"

8"x4"

2 1

EF 2

MECHANICAL KEYED NOTES:EF 2

10"x8" 1 60 5 1 60

F 2 9 3"

14" 1

8 1 80 1

7 1 EF 2 EF 1 7 7"

4" RIGID MINIMUM 26 GAUGE DRYER VENT ABOVE CEILING. PROVIDE AND INSTALL FLUSH MOUNTED BRICK VENT WITH BACKDRAFT DAMPER, FINISHED TO MATCH BRICK. PROVIDE FIRE CAULK SEALANT AT CEILING PENETRATION. 4" RIGID MINIMUM 26 GAUGE EXHAUST VENT ABOVE CEILING. PROVIDE AND INSTALL FLUSH MOUNTED BRICK VENT WITH BACKDRAFT DAMPER, FINISHED TO MATCH BRICK. PROVIDE FIRE CAULK SEALANT AT CEILING PENETRATION. 7" RIGID MINIMUM 26 GAUGE KITCHEN EXHAUST VENT ABOVE CEILING. PROVIDE AND INSTALL FLUSH MOUNTED BRICK VENT FINISHED TO MATCH BRICK. PROVIDE FIRE CAULK SEALANT AT CEILING PENETRATION. CONDENSATE DRAIN PIPING FOR AC-1 ROUTE 3/4" CONDENSATE DRAIN PIPE TO TERMINATE INTO FLOOR DRAIN IN FIRE SERVICE ROOM. PROVIDE DRYER BOX SIMILAR TO DRYERBOX MODEL 425. INSTALL PER MFRS RECOMMENDATIONS. ROUTE 4" RIGID 26 GUAGE METAL DUCT ABOVE CEILING AS INDICATED, PROVIDE FIRE CAULK SEALANT AT CEILING PENETRATION. RTU-4 SHALL BE CONTROLLED BY TWO T-STATS, ONE ON THE FIRST FLOOR OF THE STAIRS AND ON THE THIRD FLOOR CORRIDOR, USE THE AVERAGE TEMPETURE BEWTEEN THE STATS AS THE SET POINT. PROVIDE AND INSTALL A CLEAR TAMPERPROOF VENTILATED LOCKBOX ON THE THERMOSTAT. BOTTOM OF RETURN AIR GRILLE MOUNTED APPROXIMATELY 7'-6' ABOVE FINISHED FLOOR. MOUNT UNIT IN A VERTICAL ORIENATION ON SHELF ABOVE WATER HEATER. PROVIDE DRAIN PAN UNDER UNIT WITH OVERFLOW CUT-OFF SWITCH IN PAN. CONNECT RETURN AIR DUCT TO SIDE OF UNIT AND EXTEND UP. LOCATE RETURN AIR GRILLES IN DUCT AND WALL AS INDICATED. EXTEND AND CONNECT 3/4" GAS LINE FROM GAS METER TO THE FURNACE. PROVIDE A TRAPPED CONDENSATE DRAIN LIN FROM FURNACE AND ROUTE OPEN ENDED TO FLOOR DRAIN. EXTEND BOTH A 3" EXHAUST AND 3" COMBUSTION AIR PIPE FORM FURNACE UP THROUGH CHASE AND ATTIC AND TERMINATE WITH CONCENTRIC VENT PIPE A MINIMUM OF 12" ABOVE ROOF.OFFSET BOTH VENT SETS SUCH THAT TERMINATION OF VENTS ARE AWAY FROM THE MIDDLE OF THE BUILDING. ROUTE 3/4" GAS LINE FROM GAS METER TO FURNACE. PROVIDE ALL ACCESSORIES SUCH AS SHUT-OFF VALVES THAT ARE REQUIRED. 36 GAS METERS REQUIRED FOR THIS BUILDING. COORDIATE EXACT METER LOCATIONS WITH G.C. AND GAS COMPANY BEFORE INSTALLATION OF ANY GAS PIPING. FURNACE COMBUSTION AIR AND EXHAUST AIR ROUTED UP INSIDE CORRIDOR WALLTO TO OFFSET AND CONNECT TO CONCENTRICA VENT THRU ROOF. PROVIDE REFRIGERANT PIPING ROUGH IN, & ELECTRICAL WORK PADS FOR FUTURE CONDENSING UNIT. SUPPLY AIR UP TO FLOOR ABOVE. PROVIDE 1" DUCT LINING. SIZES ARE OUTSIDE DIMENSIONS AND INCLUDE 1" DUCT LINING. 22"X16' RETURN AIR UP TO FLOOR ABOVE. PROVIDE RETURN AIR GRILLE 18' AFF. PROVIDE FIRE DAMPER AT FLOOR.

2.

2 3

3 2 8 200 10" 1 50 9 12"x12" 8" 8" 12"x12" EF 1 500 8" 8" 11 1 12"x12" 12"x10"

7"

CORRIDOR11 8 200 10"x10" 8"

200

4" 1 WH BELOW FURNACE D 8

12 150

8 200

11 11 11 120 10" 11 120

4 5

7"

7"

ELEV.10014

LOBBY213G 11 120

3

7"

8 200 7" 11

EF 1 1 1 50

1 11 100 20"x10" 1 50 8"x4" 11 100 1 50 8"x4" 8" 11 100 14" 9 A

4"

7 A 9

8 200

7 8

1

11 100 14"

11 100

11 100

7 8"x4" 1 50 15 12" 10"

COMMUNITY ROOM214

MECHANICAL1

215

500

11 120

12"x6"

2BR/2BA2072 12"x10" 11 100 11 100

12"x6"

STORAGE21311 100 8"

STORAGE214

STORAGE STORAGE STORAGE215 216 217

12 150

10"

F 2 WH BELOW FURNACE

5 8 11 100 14" 11 100 T 8"

5

11 100 T

11 100

F 2

10" 8 12 150 UP

DN

1 8" 4" 4" D T 5

2BR/2BAD

3 125

3 125

4"

WH BELOW FURNACE

11 120

9 10

2BR/2BA201

1 D

203D 4" 4" D

114"

12"x6" 3 125

8"x4" EF 2

216

4"

1 50

1

STORAGE

STAIR212

12 13

NORTH SARAH REDEVELOPMENT - PHASE 2 BUILDING AND ONSITE IMPROVEMENTS

F 2

A

7

500

F 1

F 1

7"

EF 2

EF 2

1

7"

EF 1

6

8 200 EF 2

EF 2 1 50 8"x4" 12"x6" D 3 125

2.

2.

2.

1.

2.

3.

14 15

3.

4"

3 125 12"x6" 8"x4" 4" 5

1 50

2

D

CORRIDOR8"

2008" 1

5

T 1.

T

2BR/2BA208

11 100

11 100

8"

11 100

11 100

2.

2BR/2BA14"

20914" 1 11 100 11 100

7" 3

11 100

7"

8 200 A 800 9 EF 1

11 100 WH BELOW FURNACE F 2 D

7 D 10"x10" 8 WH BELOW FURNACE 12 150 4" 2 F 2 9 1 50 8" A 11

7

8

C:\Users\rlowery.WESINC\Documents\Building-MU-B_MEP_rlowery.rvt

10"

EF 1

1 50

12 150 4"

2 3

1

MECHANICAL - SECOND FLOOR PLAN

10"

SAINT LOUIS, MO 63113

211 North Broadway Suite 1900 Saint Louis, MO 63102 T. 314.241.8188 F. 314.241.0125 www.kai-db.com

12"x6"

3 DW 1 80 8 8 200 12 175 12"x10" 12"x6" D 500 12"x6" A 7 D 500 F 2 9 1 60 5 1 60 10"x8" 4" EF 2 1

STAIR211

UP

2

MARK DATE DESCRIPTION 1 10/16/12 Addendum 1

DN

12 175

T

D 0

D 0

3 125

2BR/1BA210

3 125

SHEET TITLE:

KAI PROJECT NO.

10-11029 10/16/2012 12:45:20 PMTOTAL SHEET SIZE IS 42" x 30" ISSUE DATE

10/2/2012SHEET NO.

BID SET 2 0 1 2 W EB B

1

SECOND FLOOR PLAN - MECHANICAL3/16" = 1'-0"

MB-M1-02

I hereby specify, pursuant to RSMo 327.411, that this drawing sheet is authenticated by my seal. A-000391 : E-000949

2.

3.

3.

3.

GENERAL NOTES:1. THESE DRAWINGS ARE DIAGRAMMATIC IN NATURE, ALL WORK IS TO BE COORDINATED BETWEEN ALL TRADES BEFORE CONSTRUCTION. 2. ALL DUCTWORK, EQUIPMENT AND PIPING IS TO BE INSTALLED IN ACCORDANCE WITH ALL PERTINENT CODES. D 3. DUCT SIZES SHOWN ARE SHEETMETAL SIZES. 4. CONTRACTOR SHALL COORDINATE CONDENSING UNITS ON THE ROOF WITH GENERAL CONTRACTOR.

1.

2.

1.

2.

2.

D 4" 4" D 1 WH BELOW FURNACE 12"x6" 12 150 10" 10" 12"x6" 9 14" 8"x4" 12 175 1 12"x10" 12 175 2" 2" 10"x8" 1 60 4" 3 7" 8" 8" 2 8 200 1 50 9 A 7 8" D 8 F 2 12"x12" 8" EF 1 11 500 5 7" 1 60 F 2 3" 8 7" 1 80 DW F 2 11 100

D

1BR4" 4" 4"

305

D 1

1BR7"

4"

1BR 2BR/1BA3067" 3 125 D 0 D 0 3 125 11 100 11 100 14"

8 T F 1 3 125 9

306

3 125 T 12"x6" 8 14" 11 100 5 12 150 WH BELOW FURNACE 10" F 2 8

304

3 125 12"x6"

5. CONTRACTOR HAS THE OPTION TO RUN ROUND DUCT IN LIEU OF RECTANGULAR DUCT AT NO ADDITIONAL COST. SIZES OF ROUND DUCT SHALL HAVE SIMILAR FREE AREAS. 6. ALL EXTERIOR EXHAUST AND/OR INTAKE WALL VENT CAPS SHALL BE FIELD PAINTED, COLOR SHALL BE PER ARCHITECT. 7. CLOTHES WASHER TO BE ON THE LEFT, AND DRYER TO BE ON THE RIGHT REGARDLESS WHETHER UNIT CONFIGURATION IS MIRRORED.

11 100

11 100 5

1.

7 12"x6" A 800 D 500 D 500

4"

8"x4"

11 100

11 100 WH BELOW FURNACE

5 1 50 EF 2 EF 1 9 A 11 100 11 100

8"

1 50 1 50

9 A

14" 11 100 11 100

MECHANICAL KEYED NOTES:

8" 1 50

1EF 2

2

8"x4"

EF 2 4"

1

1 50

4" RIGID MINIMUM 26 GAUGE DRYER VENT ABOVE CEILING. P