Top Banner
Non-Destructive Testing of Drilled Shafts Current Practices and New Methods © 2012 Pile Dynamics, Inc. Foundation & Geotechnical Engineering Brent Robinson, Pile Dynamics, Inc.
49

Non-Destructive Testing of Drilled Shafts: Current ...

Mar 27, 2022

Download

Documents

dariahiddleston
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: Non-Destructive Testing of Drilled Shafts: Current ...

Non-Destructive Testing of Drilled Shafts

Current Practices and New Methods

© 2012 Pile Dynamics, Inc. Foundation & Geotechnical

Engineering

Brent Robinson, Pile Dynamics, Inc.

Page 2: Non-Destructive Testing of Drilled Shafts: Current ...

Why Test Integrity?

Page 3: Non-Destructive Testing of Drilled Shafts: Current ...

Survey of State DOT Practice:

94% use CSL

3% use G-G

3% use PIT

Ref: Khamis Haramy, FHWA Denver 2008

Page 4: Non-Destructive Testing of Drilled Shafts: Current ...

Anomaly Location (anomaly is not always a defect)

Bottom 2

Diam.

41%

Middle

13%

Top 2

Diam.

46%Bottom 1/3

45%

Mid 1/3

11%

Top 1/3

44%

Billy Camp, S&ME Inc.

Southeast USA

.

“Crosshole Sonic Logging of

South Carolina Drilled Shafts: A

Five Year Summary”

Proceedings of GeoDenver,

ASCE, Feb 2007

Jones & Wu, Geotechnology, Inc.

Missouri and Kansas

“Experiences with Cross-hole Sonic

Logging and Concrete Coring for

Verification of Drilled Shaft Integrity”,

ADSC GEO3 Construction Quality

Assurance/Quality Control Technical

Conference, Dallas Nov 2005

Percentage of Shafts with Anomalies

33% 38%

Page 5: Non-Destructive Testing of Drilled Shafts: Current ...

CSL Cross-hole Sonic Logging

Stress Waves, emitted

in one tube are received

in another one if concrete

quality is satisfactory

Fill Tubes with water

Pull Probes From Bottom To Top

Transmit Receive

Top view of pile with

4 access tubes –

test all paths

Page 6: Non-Destructive Testing of Drilled Shafts: Current ...

Cross-hole Sonic Logging

Advantages

• Checks concrete quality inside cage

• by depth and by quadrant

• Tomography available for complicated cases

Limitations / Disadvantages

• Needs access tubes (steel tubes preferred)

• Wait min 3 days prior to test (7 days preferred)

• Cannot evaluate concrete cover

Page 7: Non-Destructive Testing of Drilled Shafts: Current ...

Indiana Drilled Shaft—Soft Toe

Length: 92 feet

Geometry:

7 ft diameter, upper 16 ft, temporary casing

6 ft diameter, 16 to 92 ft (top of rock),

temporary casing

5.5 ft diameter, 72 to 92 ft (20 ft rock socket)

CSL Results:

Arrival delays of 50 to 100% on all profiles

Over bottom 1-2 ft of shaft

Page 8: Non-Destructive Testing of Drilled Shafts: Current ...
Page 9: Non-Destructive Testing of Drilled Shafts: Current ...
Page 10: Non-Destructive Testing of Drilled Shafts: Current ...

Core Results “Tools dropped from 88 to 91 ft”

Recovered 7” concrete, 38.75” void, 21.25” sandstone

Page 11: Non-Destructive Testing of Drilled Shafts: Current ...

Indiana Drilled Shaft—Top Same project, different shaft

Similar geometry, slightly longer

Anomaly identified near the top

CSL identifed 20-100% reductions within 2-5 ft

of top

Page 12: Non-Destructive Testing of Drilled Shafts: Current ...

Core results Core samples compression tested

Compressive strength

6000 to 7000 psi

Cage was wet slabbed

Concrete poured

Cage installed

Page 13: Non-Destructive Testing of Drilled Shafts: Current ...

Small hammer

impact device Accelerometer

measures response

(defect)

Low Strain Integrity Testing:

- Looks for major defects

Page 14: Non-Destructive Testing of Drilled Shafts: Current ...

Advantages • Cost Effective

• Apply to any or even all concrete pile/shaft

minimal pile preparation

• Finds MAJOR defects

• Sometimes test piles in structure

Limitations / Disadvantages • Best use: CFA/ACIP or drilled shafts

• Solid section of concrete needed

• Limited to 30 to 50 L/D

• Difficult interpretation for highly non-uniform

• Cannot locate defect quadrant

Page 15: Non-Destructive Testing of Drilled Shafts: Current ...

Indiana Shafts—PIT results

v

Page 16: Non-Destructive Testing of Drilled Shafts: Current ...

Gamma-Gamma Logging Advantages

• Gives data on concrete cover

perhaps to 3 inch range

rad.energy halved every 2”

• Compliments CSL testing

Disadvantages

• Needs many PVC access tubes (3 inch range)

(steel access tubes generally preferred for CSL)

• Uses radioactive materials (Cesium 137)

Probe must be retrieved

( note: long probe vs. bent PVC tubes)

Page 17: Non-Destructive Testing of Drilled Shafts: Current ...

0%

10%

20%

30%

40%

50%

60%

70%

80%

90%

100%

3 4 5 6 7 8 9 10

Shaft Diam. (ft)

Te

sti

ng

Co

ve

rag

e

GGL Shaft Tested GGL Cover Tested CSL Shaft Tested CSL Cover Tested

CSL GGL

Page 18: Non-Destructive Testing of Drilled Shafts: Current ...

Thermal Integrity Profiling

Temperature from concrete curing is directly related to concrete quality

Heat from concrete curing evaluates concrete both inside and outside cage

(100% testing – entire section)

Obtain temperature vs. depth vs. quadrant

Infra-red probe via CSL tubes

Thermal wires on cage cast in shaft

Test can reveal cage alignment problems Minimum cover can be verified

Page 19: Non-Destructive Testing of Drilled Shafts: Current ...

1 4 7

10

13

16

19

22

25

28

31

34

37

40

43

46

49

S1

S10

S19

S28

S37

S46

20

30

40

50

60

70

80

70-80

60-70

50-60

40-50

30-40

20-30

Shaft Heat Signature Tem

pera

ture

Page 20: Non-Destructive Testing of Drilled Shafts: Current ...

0

5

10

15

20

25

30

35

40

45

50

110 120 130 140 150

De

pth

(ft

.)

Degrees F

Data Interpretation Cage alignment

A1

A2

AVG

Data Interpretation

Cage Alignment

Page 21: Non-Destructive Testing of Drilled Shafts: Current ...

Data Interpretation Local Defect

0

5

10

15

20

25

30

35

40

45

50

90 110 130 150

De

pth

(ft

.)

Degrees F

Data Interpretation Local Defect near C2

C1

C2

Average

C1 C2

Page 22: Non-Destructive Testing of Drilled Shafts: Current ...
Page 23: Non-Destructive Testing of Drilled Shafts: Current ...

Test Procedure using probes

H2O Container

•Transfer water from first tube into container

•Warm temperature probe

•Lower probe into tube – data collected

from top to bottom – 1’/sec. rate

•Remove probe

•Transfer water from second tube into first

•Repeat scan in second tube

•Continue for all remaining tubes

CSL

Tubes

To

Depth

Encoder

Page 24: Non-Destructive Testing of Drilled Shafts: Current ...

Thermal Integrity Profiler (TIP) - probe testing

Page 25: Non-Destructive Testing of Drilled Shafts: Current ...

TAP TAP

TIP Computer

Thermal wires

25

Thermal Wire Data Collection

Future: Wireless transmission from TAP to computer, and offsite

Page 26: Non-Destructive Testing of Drilled Shafts: Current ...

Thermal wires

eliminate need for

access tubes

Page 27: Non-Destructive Testing of Drilled Shafts: Current ...

Interpretation: Direct Observation (Field)

Verify shaft length - Identify top and bottom

Confirm cage alignment

Locate changes in shaft diameter

Locate immediate areas of concern

Page 28: Non-Destructive Testing of Drilled Shafts: Current ...

Field Observations:

Scatter Creek, Florida

No cage eccentricity

(all tubes ~same temp)

Clean top and toe

signature (approximate

1 diameter temperature

roll-off top and bottom)

Good Shaft

0

5

10

15

20

25

30

35

40

70 80 90 100 110 120

Temperature (deg F)

Depth

(ft)

T1

T2

T3

T4

Avg

Scatter Creek

Shaft A

Page 29: Non-Destructive Testing of Drilled Shafts: Current ...

Interpretation: Added Field Records

Confirm direct observations and preliminary

information

Find relationship between concrete volume

and measured temperature

Predict as-built shaft radius, shape, and

cover

Correlate soil strata to thermal conductivity and

observe influence on less prominent

temperature fluctuations

Page 30: Non-Destructive Testing of Drilled Shafts: Current ...

0

10

20

30

40

50

60

70

80

90

100

70 90 110 130 150

Temperature (deg F)D

epth

(ft)

0 2 4 6 8 10

Shaft Diam (ft)

Average

Grnd Surf

TOS

WT

BOC

TOLime

TOR

BOS

Effective

Diam.

Theoretical

Diam.

Method ShaftNo Correction for

Over-pour Concrete

No Correction for

Tremie f illing /

volume

Shape of avg.

profile mimics

diameter from

concrete yield

Average temp. is

determined for a

given truck yield

(diam.)

Results plotted

to establish

correlation

0.8 inch / degree

Page 31: Non-Destructive Testing of Drilled Shafts: Current ...

How to determine cover?

Correlate temp. with concrete volume

Measure the temperature “gradient”

Thermal Wire option

Short parallel separate wire of known offset

Attach to cross brace

Simplifies the interpretation

Model the mix to get the “gradient”

Page 32: Non-Destructive Testing of Drilled Shafts: Current ...

Case Study –FHWA WFLHD

Page 33: Non-Destructive Testing of Drilled Shafts: Current ...

Shaft Details

Halstead Medows Bridge

Tubes (3) and T-wires (4 +2 Grad)

38 inch diameter casing (0-20’)

36 inch diameter (20-49’)

30 inch rebar diameter

49 ft long

~18% more concrete required

CSL and Thermal Testing

Poured 9/19/2011

Tube 3

Tube 2

Tube 1

G

003

002 001

000

Page 34: Non-Destructive Testing of Drilled Shafts: Current ...

Abutment 2 Pier 2

SW-SM

SM

SM

Page 35: Non-Destructive Testing of Drilled Shafts: Current ...
Page 36: Non-Destructive Testing of Drilled Shafts: Current ...

Abutment 2 Pier 2

Page 37: Non-Destructive Testing of Drilled Shafts: Current ...

Basic Temperature Display Abutment 2 Pile C

-50

-45

-40

-35

-30

-25

-20

-15

-10

-5

0

50 70 90 110 130

De

pth

(ft

)

Temperature (F)

000

001

003

004

Average

Refusal

Page 38: Non-Destructive Testing of Drilled Shafts: Current ...

Corrected Shaft Radius Display Abutment 2 Pile C

Page 39: Non-Destructive Testing of Drilled Shafts: Current ...

-5

0

5

10

15

20

25

30

35

40

45

50

55

60

-3 -2 -1 0 1 2 3D

ep

th (

ft)

Shaft Radius (ft)Sequoia Abutment 2 Pile C

-5

0

5

10

15

20

25

30

35

40

45

50

55

60

-3 -2 -1 0 1 2 3

De

pth

(ft

)

Shaft Radius (ft)Sequoia Abutment 2 Pile C

3D Representation Abutment 2 Pile C

Page 40: Non-Destructive Testing of Drilled Shafts: Current ...

CSL Results – Abutment 2 Pile C

Page 41: Non-Destructive Testing of Drilled Shafts: Current ...

Abutment 2 Pier 2

Page 42: Non-Destructive Testing of Drilled Shafts: Current ...

-60

-50

-40

-30

-20

-10

0

10 15 20 25 30

Dep

th (

ft)

Shaft Radius (in)

009 radius

010 radius

011 radius

012 radius

Cage

18 inches

average

Corrected Shaft Radius Display Pier 2 Pile C

Page 43: Non-Destructive Testing of Drilled Shafts: Current ...

-5

0

5

10

15

20

25

30

35

40

45

50

55

60

65

-3 -2 -1 0 1 2 3D

ep

th (

ft)

Shaft Radius (ft)

Sequoia Pier 2 Pile C

-5

0

5

10

15

20

25

30

35

40

45

50

55

60

65

-3 -2 -1 0 1 2 3

De

pth

(ft

)

Shaft Radius (ft)

Sequoia Pier 2 Pile C

3D Representation Pier 2 Pile C

Page 44: Non-Destructive Testing of Drilled Shafts: Current ...

CSL Results – Pier 2 Pile C

Page 45: Non-Destructive Testing of Drilled Shafts: Current ...

Abutment 2 and Pier 2

-5

0

5

10

15

20

25

30

35

40

45

50

55

60

65

-3 -2 -1 0 1 2 3

De

pth

(ft

)

Shaft Radius (ft)

Sequoia Pier 2 Pile C

-5

0

5

10

15

20

25

30

35

40

45

50

55

60

-3 -2 -1 0 1 2 3D

ep

th (

ft)

Shaft Radius (ft)Sequoia Abutment 2 Pile C

Page 46: Non-Destructive Testing of Drilled Shafts: Current ...

Summary Significant improvements in NDT technology over the

last 20 years.

CSL, PIT and Gamma Gamma continue to provide useful information

Thermal Integrity Profiling promising for determining

Integrity of 100% of shaft

Cage location and alignment

Concrete cover

Overall profile of the shaft

Page 47: Non-Destructive Testing of Drilled Shafts: Current ...