Top Banner
Nikuni Micro-Bubble Generator www.nikunijapan.com KTM Karyu Turbo Mixer
4

Nikuni KTM catalogue A4 01Features : 1. Three Functions in One Pump - The KTM simultaneously draws in air and water, dissolves air with its turbine impeller, and pumps pressurized

Aug 08, 2020

Download

Documents

dariahiddleston
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: Nikuni KTM catalogue A4 01Features : 1. Three Functions in One Pump - The KTM simultaneously draws in air and water, dissolves air with its turbine impeller, and pumps pressurized

Nikuni Micro-Bubble Generator

www.nikunijapan.com

KTM Karyu Turbo Mixer

Page 2: Nikuni KTM catalogue A4 01Features : 1. Three Functions in One Pump - The KTM simultaneously draws in air and water, dissolves air with its turbine impeller, and pumps pressurized

Features :1. Three Functions in One Pump

- The KTM simultaneously draws in air and water, dissolves air with its turbine impeller, and pumps pressurized water to the flotation tank or other process

2. Highly Efficient Air-water Dissolution- Precision turbine pump technology and a unique

design make possible extremely high levels of efficiency in dissolving air into water

3. Simplified DAF Operation and Stable Pump Performance- The multifunctional KTM eliminates the need for

ancillary equipment such as air compressors, large saturation tanks with difficult level control, and truly simplifies DAF systems and their operation

4. Compact and Small Footprint- Easily retrofit or upgrade existing DAF systems

5. Minimal Power Consumption and Maintenance cost- Highly efficient process with small pump and motor, no

compressor power required, while the simple and robust structure of the KTM minimizes maintenance cost

“Suction, Mixing/Dissolving, and Pressurization” with just a single KTM!

Case Studies

Large scale DAF system High density micro-bubble generation

KTM Installed in parallel system

Working Principle/Mechanism

Performance Table

Recyclingwater

Suction Pressurize

Mixing and dissolving

Pressurizedwater

Air

Model

KTM20F/N

KTM25F/N

KTM32F/N

KTM40F/N

KTM50F1/S1

KTM50F2/S2

KTM50F3/S3

KTM65F2/S2

KTM80F/S

NL / min (Range)*L / min m3 / h kW / Poles NL / min (Range)*L / min m3 / h kW / Poles

50Hz Frequency 60Hz Frequency

Water Flow Rate Air Flow Rate Required Motor Power Required Motor PowerWater Flow Rate Air Flow Rate

1.0

1.5

3.0

4.8

8.0

12.0

15.0

20.0

42.0

17

25

50

80

133

200

250

333

700

1.3

2.0

4.0

6.4

11.0

16.0

20.0

27.0

56.0

(0 to 5)

(0 to 5)

(0 to 10)

(0 to 20)

(0 to 20)

(0 to 20)

(0 to 30)

(0 to 40)

(0 to 80)

0.75kW / 2P

1.5kW / 2P

2.2kW / 2P

3.7kW / 2P

5.5kW / 4P

7.5kW / 4P

11kW / 4P

15kW / 4P

22kW / 4P

1.3

2.5

4.0

7.0

11.5

15.0

18.0

28.0

58.0

22

42

67

117

192

250

300

467

967

1.7

3.3

5.3

9.3

15.0

20.0

24.0

37.0

77.0

(0 to 5)

(0 to 5)

(0 to 10)

(0 to 20)

(0 to 30)

(0 to 40)

(0 to 40)

(0 to 60)

(0 to 100)

0.75kW / 2P

1.5kW / 2P

2.2kW / 2P

3.7kW / 2P

7.5kW / 4P

11kW / 4P

15kW / 4P

18.5kW / 4P

30kW / 4P*Values in brackets show the recommended range of the air flow meter

KTM Micro-Bubble Generator(The leading solution for DAF systems & mixing applications)

Nikuni has developed a unique and compact Micro-Bubble Generator - the KTM - that creates pressurized air-enriched whitewater with highly reliable performance, insuring excellent stability in processes and systems such as DAF units in water treatment plants.

Page 3: Nikuni KTM catalogue A4 01Features : 1. Three Functions in One Pump - The KTM simultaneously draws in air and water, dissolves air with its turbine impeller, and pumps pressurized

Quick Comparison: Conventional System vs KTM for DAF System

Conventional system KTM

Major applications for DAF- Waste Water Treatment Plants for Food, Beverage, Dairy, Seafood, Poultry Processing, Laundries, Bakeries etc.

- Drinking Water Treatment Plant

- Desalination Plant

- Municipal Waste Water Plant and Power Station

- Automotive and Chemical Plant

- Petroleum or Oil & Gas Plant

- Paper Mill or Textile Industries

Other applications

- Ozone Water Processes - Dissolved Gas Flotation Systems - Oxygenation / Deoxygenation - Various Gas-Liquid / Liquid-Liquid Solutions - Hotel & SPA Facilities

Dimensions

Models: KTM20F/N to KTM40F/N

Models: KTM50F1/S1 to KTM80F/S

Advantages of KTM- Eliminate Compressor/Ejector, Static Mixer and

Saturation Vessel

- Easily retrofit to existing systems

- Improve performance of entire DAF system

- Easy operation & maintenance due to simple structure of KTM

- Save space with small footprint & compact size

General centrifugal pump /multi-stage pump

To flotation tank

Level gauge

Static mixer Relief valve

Air supplyCompressor

Ejector

Recycling water(From flotation tank)

Pressure vessel /Saturation tank

KTM

To flotation tank

Air flow meter /Rotameter

Excess air releasing valve and tank

Air in-take nozzle

Recycling water(From flotation tank)

ModelKTM20F/NKTM25F/NKTM32F/NKTM40F/N

kW PY

63708085

FC

95105120130

MH

140150150180

L

533587

597.5692

KL

146147147154

VM

225240240310

VN

385430430616

Weight

17202130

0.751.52.23.7

Note: The motor weights are not included. The motors shall be prepared by purchasers.Note: KL & L dimensions shown for reference only, will vary depending on actual motor size

(units: mm, kg)

Note: The motor weights are not included. The motors shall be prepared by purchasers.Note: KL & L dimensions shown for reference only, will vary depending on actual motor size

Model

KTM50F1/S1

KTM50F2/S2KTM50F3/S3

KTM65F2/S2

KTM80F/S

kW PY

160160170170170190190180180

FC

230230240240240240240280280

MH

204204204245245300300300360

L

836874874

1027.51027.51276.5135313561429

KL

189189189

257.5257.5256335279314

VM

352352352404404512512512430

VN

690690690878878

1285128512851250

Weight

9090

110120130240250300300

5.57.57.5111515

18.52230

(units: mm, kg)KL

FC

PY

VM

L

MH

VN

KL

FC

PY

VM

L

MH

VN

Page 4: Nikuni KTM catalogue A4 01Features : 1. Three Functions in One Pump - The KTM simultaneously draws in air and water, dissolves air with its turbine impeller, and pumps pressurized

The contents of this catalog may be changed without any notice.

2018.07

Overseas Subsidiaries

Head Office

Nikuni Co., Ltd. (Japan)

Headquarters : 843-5, Kuji, Takatsu-ku, Kawasaki, Kanagawa, 213-0032 Japan

Tel: +81-44-833-6500 Fax: +81-44-811-2212

Sales office : 2F Inoue Bldg. No.3, 5-8-1 Futako, Takatsu-ku, Kawasaki, Kanagawa, 213-0002 Japan

Tel: +81-44-833-6500 Fax: +81-44-833-6482

www.nikunijapan.com

Nikuni Taiwan Co., Ltd.

No.71-56, Nanshi, Neighborhood 5, Nanshi Village, Linkou District, New Taipei City, Taiwan, R.O.C.Tel: +886-2606-9385 Fax: +886-2606-9386

Nikuni America, Inc.

1878 S. Elmhurst Rd., Mt. Prospect, IL 60056Tel: +1-224-404-4051 Fax: +1-847-378-8007 [email protected]

www.nikuniamerica.com

www.nikuni-taiwan.com

Size of Air-intake Nozzle

ModelKTM20F/NKTM25F/NKTM32F/NKTM40F/NKTM50F1/S1 to KTM50F3/S3KTM65S2/F2KTM80S/F

Drawing Length (L1) Dia.(D)

Fig. A

Fig. B

121121121121129183193

R1/4BR1/4BR1/4BR1/4BR1/4BRc3/8Rc3/8

Recommended Size of Separation TankModel

KTM20F/NKTM25F/NKTM32F/NKTM40F/NKTM50S/F1KTM50F2/S2, KTM50F3/S3KTM65S2/F2KTM80S/F

A (mm) B (mm) Capacity (Liter)

230300320420800900

12001400

115165215270320460580730

248

2060

140300500

PressurizedWater Inlet

PressurizedWater Outlet

Excess Air Release Point

øA

B

Required & Recommended Accessories

Excess air separation tankSee table below for recommended tank size

Install a valve or air vent to release excess air during operation.

Pressure gaugeRange: 0 MPa / 0 bar / 0 psi to 1.0 MPa / 10 bar / 150 psi

Air flow meterRefer to performance table on page 3 for selection

Solenoid valveTo prevent backflow Settings: Pump start OPEN Pump stop CLOSE

Compound gaugeRange: -0.1 MPa / -1 bar / -15 psi to 0.25 MPa / 2.5bar / 35 psiSee note below for adjustment

Note: slightly close suction valve to create vacuum (negative pressure) in suction line during operationOptimal pressure is -0.02 MPa / -0.2 bar / -2.9 psi

Air-intake nozzleSupplied as optional accessory upon request

L1

DFig. A Fig. B

L1

D

(units: mm)