Top Banner
Medium-voltage power distribution and control systems > Motor control centers > SC9000 CI variable frequency drive— medium voltage Contents General Description 106-2 SC9000 CI Adjustable Frequency Drive 106-2 Isolated Low-Voltage Control 106-4 Pre-Charge Circuit 106-5 Standard Ratings 106-6 Devices 106-7 Isolation Switch 106-7 Contactors 106-8 Current Limiting Fuses 106-8 Accessories 106-8 Layouts and Dimensions 106-9 SC9000 CI Fully Integrated Frame A VFD 106-9 Layout Dimensions—Integrated Ampgard Main Breaker (Metal-Enclosed) 106-11 Layout Dimensions—SC9000 CI VFDs Synchronous Transfer Control 106-12 Application Details 106-13 Synchronous Transfer Control with SC9000 CI 106-13 Typical Schematic 106-15 More about this product Eaton.com/SC9000 Complete library of design guides Eaton.com/designguides Design Guide DG020006EN Effective March 2021
17

New SC9000 CI variable frequency drive— medium voltage · 2021. 4. 5. · 1250 hp in a 65-inch wide enclosure. Based on the proven SC9000 design, the CI drive allows for output

Apr 09, 2021

Download

Documents

dariahiddleston
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: New SC9000 CI variable frequency drive— medium voltage · 2021. 4. 5. · 1250 hp in a 65-inch wide enclosure. Based on the proven SC9000 design, the CI drive allows for output

Medium-voltage power distribution and control systems > Motor control centers >

SC9000 CI variable frequency drive—medium voltage

Contents

General Description . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 .6-2SC9000 CI Adjustable Frequency Drive . . . . . . . . . . . 10 .6-2Isolated Low-Voltage Control . . . . . . . . . . . . . . . . . . . 10 .6-4Pre-Charge Circuit . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 .6-5Standard Ratings . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 .6-6

Devices . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 .6-7Isolation Switch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 .6-7Contactors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 .6-8Current Limiting Fuses . . . . . . . . . . . . . . . . . . . . . . . . 10 .6-8Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 .6-8

Layouts and Dimensions . . . . . . . . . . . . . . . . . . . . . . 10 .6-9SC9000 CI Fully Integrated Frame A VFD . . . . . . . . . 10 .6-9Layout Dimensions—Integrated Ampgard Main Breaker (Metal-Enclosed) . . . . . . . . . . . . . . . . . 10 .6-11Layout Dimensions—SC9000 CI VFDs Synchronous Transfer Control . . . . . . . . . . . . . . . . . . 10 .6-12

Application Details . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 .6-13Synchronous Transfer Control with SC9000 CI . . . . . 10 .6-13Typical Schematic . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 .6-15

More about this product

Eaton.com/SC9000

Complete library of design guides

Eaton.com/designguides

Design Guide DG020006EN Effective March 2021

Page 2: New SC9000 CI variable frequency drive— medium voltage · 2021. 4. 5. · 1250 hp in a 65-inch wide enclosure. Based on the proven SC9000 design, the CI drive allows for output

SC9000 CI Adjustable Frequency Drive

SC9000 CI Adjustable Frequency Drive

Eaton’s SC9000E medium-voltage variable frequency drive offers a compact solution that is unparalleled to others. The SC9000 compact inverter (CI) drive is designed for use with 2400 V or 4160 V induction or synchronous motors up to 1250 hp in a 65-inch wide enclosure. Based on the proven SC9000 design, the CI drive allows for output filter mounting above the inverter, delivering an improved design while maintaining a small footprint when long cable lengths are required. The SC9000 CI is a fully integrated drive with main bus, isolation switch, power fuses and vacuum contactor.

Application DescriptionThe SC9000 CI has a standard offering:

■ Precise motor control up to 800 hp (2400 V input) or up to 1250 hp (4160 V input)

■ Compact footprint■ Industry’s lowest inverter part count improves uptime

■ Standardized architecture reduces lead time

■ Roll-in/roll-out inverter simplifies maintenance

■ Optional integrated output filters up to 1250 hp

■ 120 Vac control power provided as a standard

■ Seismic ratings per IBC 2018 and CBC 2019

■ Available in NEMAT 1 gasketed enclosures

FeaturesThe SC9000 CI drive incorporates an improved design of the highly reliable features as the SC9000 EP using the same topology:

■ Compact three-phase inverter allows for installation of output filter within enclosure of drive without increasing footprint

■ Fully compatible with Eaton’s AmpgardE medium-voltage (MV) control solutions in an MV lineup under a common main bus

■ 24-pulse transformer for IEEET 519 compliance

■ Modular roll-in/roll-out inverters■ Utilizes Eaton’s exclusive “soft-mag” pre-charge system

■ Lower spare parts count; inverter repair possible by replacing individual 6.5 kV rated power electronic components

■ Main bus, isolation switch, power fuses and main contactor are standard

BenefitsThe SC9000 CI drive brings a host of benefits for any operation:

■ Industry-leading lowest inverter part count for increased reliability

■ Time and cost savings due to low mean time to repair (MTTR)

■ Roll-in/roll-out inverter■ Fully compatible with Eaton’s entire medium-voltage product family as integrated control gear

■ Industry-leading compact design allows for installations in space limited electrical rooms reducing installation costs

Design Guide DG020006EN Effective March 2021

10 .6-2

SC9000 CI Variable Frequency Drive—Medium Voltage

EATON www.eaton.com

General Description

Page 3: New SC9000 CI variable frequency drive— medium voltage · 2021. 4. 5. · 1250 hp in a 65-inch wide enclosure. Based on the proven SC9000 design, the CI drive allows for output

Personnel Safety Features

InterlocksInterlocking on SC9000 CI includes:

■ Isolating switch mechanism locks the medium-voltage door closed when the switch is in the ON position

■ When door is open, interlock prevents the isolation switch operating handle from being moved inadvertently to ON position

■ When contactor is energized, isolating switch cannot be opened or closed

Additional Safety Features■ Provision for a padlock on the isolating switch handle in OFF position

■ Optional key interlocks on all medium-voltage doors

■ Shutter barrier between line terminals and isolation switch stabs is mechanically driven

■ Distinctive marking on back of switch assembly appears when shutter barrier is in position and starter is completely isolated from the line

■ Grounding clips provide a positive grounding of the SC9000 CI VFD and main fuses when the isolating switch is opened

■ High- and low-voltage circuits are compartmentalized and isolated from each other

■ The drawout isolation switch is easily removed by loosening two bolts in the back of the switch. The shutter remains in place when the switch is withdrawn

■ Grounding device is provided for shorting the DC bus to ground before entering the medium-voltage compartment

See Page 10 .6-7 for details on the Mechanical Non-Loadbreak Isolating Switch.

Standards and Certifications

UL and CSA CertificationAll SC9000 CI models are designed, assembled and tested to meet all applicable standards: NEMA ICS6, NEMA ICS7, IEEE 519, IEEE 1566, UL 347A and CSA C22.2. The major components (contactor, isolating switch, fuses, transformer and inverter active devices) are UL recognized.

UL or CSA labeling of a specific VFD requires review to ensure that all requested modifications and auxiliary devices meet the appropriate standards. Refer to factory when specified.

Shutter Mechanism and Finger Barrier Isolation of Incoming Line Bus (Shown with Removable Portion of Isolation Switch Removed)

Isolation Switch Operating Shaft

Mechanical Interlock with Contactor

Isolation Switch Door Locking Mechanism

Removable Cover Allows Access to Bolted Line Side Connections

Shutter Operated by Stab Motion when Isolation Switch is in Position

Distinctive Marking when Shutter is in Closed Position

Motion of Shutter

Design Guide DG020006EN Effective March 2021

10 .6-3

SC9000 CI Variable Frequency Drive—Medium VoltageGeneral Description

EATON www.eaton.com

Page 4: New SC9000 CI variable frequency drive— medium voltage · 2021. 4. 5. · 1250 hp in a 65-inch wide enclosure. Based on the proven SC9000 design, the CI drive allows for output

Isolated Low-Voltage ControlThe low-voltage door has four cutouts as standard.

SC9000 CI VFD Low-Voltage Door Closed

The device panel and optional motor protection relays fit in the low-voltage door. The standard SC9000 CI keypad can be removed for plug-in of a laptop via a serial connection. A standard viewing window allows visual verification of the SC9000 CI VFD status. The low-voltage control panel is behind the low-voltage door and is completely isolated from the medium-voltage compartment. The medium-voltage doors are interlocked with the isolation switch.

SC9000 Keypad

Control Rack Viewing Window

Indicating Lights and Pushbuttons

External Motor Protection Relay (optional)

1/4 Turn Door Latch Top and Bottom

Design Guide DG020006EN Effective March 2021

10 .6-4

SC9000 CI Variable Frequency Drive—Medium VoltageGeneral Description

EATON www.eaton.com

Page 5: New SC9000 CI variable frequency drive— medium voltage · 2021. 4. 5. · 1250 hp in a 65-inch wide enclosure. Based on the proven SC9000 design, the CI drive allows for output

Pre-Charge Circuit

SC9000 CI Soft-Mag Circuit

The SC9000 CI utilizes a soft-mag circuit pre-charge system. The isolation transformer is magnetized and the DC bus capacitors are charged at the same time. An integral three-phase step-down control power transformer is tied into the secondary windings of the isolation transformer. The soft-mag impedance limits the current and magnetizes the isolation transformer from the secondary side in-phase with the line voltage. When the main medium-voltage input contactor is closed, there is zero inrush current on the line side of the VFD.

SC9000 CI OptionsIntegrated Control Gear Under One Main Bus Options

■ Ampgard main/feeder breaker■ Incoming line section■ Load break switches■ Output contactor■ Full voltage non-reversing starter bypass

■ Reduced voltage solid-state bypass ■ Reduced voltage auto-transformer bypass

■ Reduced voltage primary reactor bypass

■ Full voltage non-reversing additional starters

■ Reduced voltage solid-state additional starters

■ Reduced voltage auto-transformer additional starters

■ Synchronous starters■ Classic Ampgard transition

Enclosure OptionsNEMA 1 Gasketed is standard and the only enclosure option at this time. If an outdoor installation is required, Eaton can supply the VFDs and other electrical equipment in a modular building called an Integrated Power Assembly.

SC9000 CI Monitoring and Protection Options a

■ Eaton Power XpertT meters■ Eaton EMR-4000 motor protection relays with RTDs

■ Eaton EMR-5000 motor protection relays with RTDs

■ Redundant fans with automatic switchover

■ Motor RTD protective device

a Limited space available for control and monitoring devices. Consult factory if large control schemes or devices are required.

Standard Protection■ Electronic overload (49)■ Instantaneous overcurrent (50)■ AC time overcurrent (51)■ Underload (37)■ Current imbalance (46)■ Line/load phase loss (46)■ Line/DC bus overvoltage (59)■ Line/DC bus undervoltage (27)■ Line phase rotation (47)■ Lockout/start inhibit (86)■ Load ground fault (50N/59G)

Standard Monitoring■ Frequency reference■ Output frequency■ DC bus voltage■ Motor voltage■ Motor current■ Motor power %■ Total kWh■ Run time ■ Unit temperature

(See IB020002EN for more details)

Communications Options ■ Johnson Controls N2■ Modbus TCP■ Modbus■ PROFIBUST DP ■ DeviceNet ■ BACnet■ CANopen■ LonWorksT ■ EtherNet/IP

SC9000 CI Output FiltersDrive output filters are recommended for longer cable lengths between the drive and motor.

Table 10.6-1. Recommended Output Filter ApplicationMotor Type Motor Lead Length (ft)

dv/dt Filter Sine Filter

Non-inverterduty rated

>120 >500

Inverterduty rated

>300 >1250

Design Guide DG020006EN Effective March 2021

10 .6-5

SC9000 CI Variable Frequency Drive—Medium VoltageGeneral Description

EATON www.eaton.com

Page 6: New SC9000 CI variable frequency drive— medium voltage · 2021. 4. 5. · 1250 hp in a 65-inch wide enclosure. Based on the proven SC9000 design, the CI drive allows for output

Standard RatingsTable 10.6-2. Design Specifications Description NEMA

CI

Power rating 100–1250 hp a

Motor type Induction and synchronous

Input voltage rating 2400–4160 V

Input voltage tolerance ±10% of nominal

Power loss ride-through 5 cycles (std.)

Input protection Metal oxide varistor

Input frequency 50/60 Hz, ±5%

Input power circuit protection Contactor/fuses

Input impedance device Isolation transformer

Output voltage 0–2400 V0–4160 V

Inverter design PWM

Inverter switch IGBT

Enclosure NEMA 1 gasketed

Ambient temperature (without derating) 0 ºC to +40 ºC

Storage and transport temperature –40 ºC to +76 ºC

Relative humidity 95% noncondensing

Altitude (without derating) 0–1000 m

Seismic IBC 2018 and CBC 2019

Standards NEMA, cUL, UL, IEEE Std. 1566

Air cooling Forced air

Average watts loss bc 23 watts/hp

Input power factor >0.98

Number of inverter IGBTs

2400 V, 4160 V 6 IGBTs / 6 choppers

IGBT PIV rating

2400 V, 4160 V 6500 V

Rectifier designs 24-pulse

Rectifier switch Diode

Rectifier switch failure mode Non-rupture, non-arc

Rectifier switch cooling Air-cooled

Output waveform to motor Sinusoidal current/voltage

Speed regulation 0.1% without tach feedback

Output frequency range 1–120 Hz

Service duty rating Standard

Typical efficiency 97%

Flying start capability d Yes

a For hp ratings up to 12,000, refer to SC9000 EP design guide.b Reflects conservative estimate. Actual amounts may vary.c Estimate additional 2 W/hp heat loss for DVDT or sine filter (see IB2002EN for more details).d Not provided when sine filter is utilized.

Design Guide DG020006EN Effective March 2021

10 .6-6

SC9000 CI Variable Frequency Drive—Medium VoltageGeneral Description

EATON www.eaton.com

Page 7: New SC9000 CI variable frequency drive— medium voltage · 2021. 4. 5. · 1250 hp in a 65-inch wide enclosure. Based on the proven SC9000 design, the CI drive allows for output

Isolation Switch

Mechanical Non-Loadbreak Isolating Switch

JMT-400 Isolation Switch Front View

JMT-400 Isolation Switch Rear View

General DescriptionEaton’s Type JMT-4 is a drawout, light-weight, three-pole, manually operated isolating switch mounted in the top of the starter enclosure. They may be easily removed by loosening two bolts in the rear of the switch. The JMT-4 is rated to 400 A continous and has a mechanical life rating of 10,000 operations.

The component-to-component circuitry concept includes the mountings for the current limiting fuses as part of the isolating switch.

FeaturesA positive mechanical interlock between the isolating switch handle mechanism and contactor prevents the isolating switch from being opened when the contactor is closed or from being closed if the contactor is closed.

An operating lever in the isolating switch handle mechanism is designed to shear off if the operator uses too much force in trying to open the non-loadbreak isolating switch when the contactor is closed. This feature ensures that the operator cannot open the switch with the main contactor closed, even if excessive force is used on the operating handle.

To operate the isolating switch, the operating handle is moved through a 180º vertical swing from the ON to the OFF position. In the ON position, a plunger on the back of the handle housing extends through a bracket on the rear of the starter high-voltage door, preventing the door from being opened with the switch closed. When the high-voltage door is open, a door interlock prevents the handle from being inadvertently returned to the ON position.

When the operating handle is moved from ON to OFF, copper stabs are withdrawn from incoming line fingers. As the stabs withdraw, they are visible above the top of the fuses when viewed from the front, and simultaneously grounded. As the fingers are withdrawn, a spring-driven isolating shutter moves across the back barrier to prevent front access to the line connections. As the shutter slides into position, distinctive markings appear on the back barrier, making it easier to check the position of the shutter.

Isolation Switch Auxiliary Contacts

Optional Blown Fuse Indicator Contacts

Switch Operating Arm

Control Plug

Line Side Access Panel (Removable From Front)

Line Side Connections

Switch Handle Open

Switch Handle Closed

Design Guide DG020006EN Effective March 2021

10 .6-7

SC9000 CI Variable Frequency Drive—Medium Voltage

EATON www.eaton.com

Devices

Page 8: New SC9000 CI variable frequency drive— medium voltage · 2021. 4. 5. · 1250 hp in a 65-inch wide enclosure. Based on the proven SC9000 design, the CI drive allows for output

Contactors

Type SL Vacuum Contactor Stab-in with Wheels, Fuses, and Line and Load Fingers

400 A Stab-In Contactor and Fuse Assembly

400 A Vacuum ContactorsThe standard stab-in SL contactor is mounted on wheels and rolls into the SC9000 CI structure. Contactor line and load fingers engage cell-mounted stabs as the contactor is inserted into the SC9000 CI incoming cell. The contactor is held in position by a bolt and bracket combination. It can be easily withdrawn from the SC9000 CI incoming cell by removing the bolt holding the contactor against the bracket and disconnecting the isolation switch interlock. The contactor can be removed from the SC9000 CI after disconnecting the medium-voltage cables going to the control transformer.

400 A Stab-In Contactor Mechanical Interlock and Fingers

Current Limiting FusesThe SC9000 CI use Eaton’s Type HLE power fuses with special time/current characteristics. The fuse is coordinated with the contactor to provide maximum motor/transformer utilization and protection. The standard mounting method for power fuses is bolted onto the contactor assembly.

Interruption is accomplished without expulsion of gases, noise or moving parts. Type HLE fuses are mounted in a horizontal position. When a fault has been cleared, an indicator in the front of the fuse, normally depressed, pops up to give visible blown fuse indication.

The control circuit primary fuses are also current limiting.

Blown Fuse Indicating Device

Accessories

Remote OperatorA remote operator for the starter isolation switch is an available option. The Ampgard Remote Operator (ARO) enables users to open or close the switch through the use of a pushbutton station operated up to 30 feet away from the starter. Users can mount the ARO on the front of the starter, plug it into any available 120 Vac source, then easily operate the isolation switch from outside the starter arc flash boundary.

Ampgard Remote Operator

Mechanical Interlock with Isolation Switch

Roll-Out Wheels

Self-Aligning Contactor Line and Load Fingers

Fuse Fault Indicator

Design Guide DG020006EN Effective March 2021

10 .6-8

SC9000 CI Variable Frequency Drive—Medium VoltageDevices

EATON www.eaton.com

Page 9: New SC9000 CI variable frequency drive— medium voltage · 2021. 4. 5. · 1250 hp in a 65-inch wide enclosure. Based on the proven SC9000 design, the CI drive allows for output

SC9000 CI Fully Integrated Frame A VFD (100–1250 hp at 4160 V) (300–900 hp at 2400 V)Horsepower ratings based on 1800 RPM motors, variable torque, standard temperature and elevation.

Line and Load Cable Terminations

24-Pulse Rectifier

Optional Output Filter

DC Link Grounding Pad

Standard Main Blower

Non‐Loadbreak Isolating Switch

24-Pulse Transformer

Type SL Vacuum Contactor Assembly

Roll-In Roll-Out Inverter

Design Guide DG020006EN Effective March 2021

10 .6-9

SC9000 CI Variable Frequency Drive—Medium Voltage

EATON www.eaton.com

Layouts and Dimensions

Page 10: New SC9000 CI variable frequency drive— medium voltage · 2021. 4. 5. · 1250 hp in a 65-inch wide enclosure. Based on the proven SC9000 design, the CI drive allows for output

Layout Dimensions—Frame A VFD (100–1250 hp at 4160 V) (300–900 hp at 2400 V)

Figure 10.6-1. SC9000 CI VFD Frame A Maximum Dimensions and Incoming Line Layouts—Dimensions in Inches (mm)

Design Guide DG020006EN Effective March 2021

10 .6-10

SC9000 CI Variable Frequency Drive—Medium VoltageLayouts and Dimensions

EATON www.eaton.com

Page 11: New SC9000 CI variable frequency drive— medium voltage · 2021. 4. 5. · 1250 hp in a 65-inch wide enclosure. Based on the proven SC9000 design, the CI drive allows for output

Layout Dimensions—Integrated Ampgard Main Breaker (Metal-Enclosed)

Figure 10.6-2. Eaton Medium-Voltage Integrated Control Gear with Main Breaker Dimensions

Design Guide DG020006EN Effective March 2021

10 .6-11

SC9000 CI Variable Frequency Drive—Medium VoltageLayouts and Dimensions

EATON www.eaton.com

Page 12: New SC9000 CI variable frequency drive— medium voltage · 2021. 4. 5. · 1250 hp in a 65-inch wide enclosure. Based on the proven SC9000 design, the CI drive allows for output

Layout Dimensions—SC9000 CI VFDs Synchronous Transfer Control

Figure 10.6-3. SC9000 CI Synchronous Transfer System with four MV Starters (For Reference Only)

Design Guide DG020006EN Effective March 2021

10 .6-12

SC9000 CI Variable Frequency Drive—Medium VoltageLayouts and Dimensions

EATON www.eaton.com

Page 13: New SC9000 CI variable frequency drive— medium voltage · 2021. 4. 5. · 1250 hp in a 65-inch wide enclosure. Based on the proven SC9000 design, the CI drive allows for output

Synchronous Transfer Control with SC9000 CI

Synchronous Transfer Control System

General DescriptionSynchronous transfer systems help maximize capital efficiency by controlling multiple motors with one adjustable frequency drive.

Most manufacturers’ synchronous transfer control systems have multiple drive output and motor select contac tors that are (typically) interconnected via cables to allow the VFD to manage multiple motors.

With the SC9000 CI and Eaton’s integrated medium-voltage control gear design; the double bus design, drive output, and motor select contactors are all close-coupled under a common bus with no cables, providing a more compact design and superior performance. 400 A bypass/motor select starters can be provided in a 2-high stacked configuration.

Closed Transition Transfer Control OperationOperation of Eaton’s Closed Transition Transfer Control System is described and illustrated below. Figure 10 .6-4 shows the elements that make up an SC9000 CI synchronous transfer system.

Control Elements, Colors, and Symbols

Figure 10.6-4. Closed Transition Synchronous Transfer Elements

Sequence of OperationStart and sync-up sequence

■ Customer sends start signal to PLC■ PLC closes the motor select contactor ■ PLC sends run command to VFD■ VFD closes output contactor and pre-charges

■ VFD closes input contactor (Figure 10 .6-5)

■ VFD ramps motor to reference frequency

Figure 10.6-5. VFD Starts Motor #1

■ Customer sends sync up signal to PLC■ PLC sends sync up command to VFD ■ VFD locks output to match line voltage ■ VFD sends sync acknowledgement to PLC

■ PLC closes bypass contactor ■ PLC opens motor select contactor (Figure 10 .6-6)

Figure 10.6-6. VFD Transfers Motor #1

■ VFD stops inverter■ VFD opens drive output contactor (Figure 10 .6-7)

■ PLC removes sync up and run command from VFD

Figure 10.6-7. Motor #1 on Bypass

Sync Down Sequence■ Customer sends signal to PLC to sync down motor

■ VFD closes main input contactor ■ VFD closes main input contactor■ VFD locks to line voltage■ VFD closes drive output contactor ■ VFD sends sync acknowledgment to the PLC

Figure 10.6-8. VFD Synched to Input

■ PLC closes motor select (Figure 10 .6-8)■ PLC sends command to VFD to turn on inverter

■ PLC opens bypass contactor (Figure 10 .6-9)

■ VFD ramps motor to reference frequency

Figure 10.6-9. VFD Running Motor #1

PLC—Transfer Programmable Logic Controller

De-Energized Energized Feeder Bus

Energized VFD Bus Closed Contactor

VFD M

Input Contactor

SC9000 VFD

Reactor*

Output Contactor*

Bypass Contactor

Motor

Motor SelectContactor

4160 V, 60 Hz, Line

VFD Bus *Optional

VFD

4160 V, 60 Hz, Line

VFD Bus

1 2 n

VFD

4160 V, 60 Hz, Line

VFD Bus

1 2 n

VFD

4160 V, 60 Hz, Line

VFD Bus

1 2 n

VFD

4160 V, 60 Hz, Line

VFD Bus

1 2 n

VFD

4160 V, 60 Hz, Line

VFD Bus

1 2 n

Design Guide DG020006EN Effective March 2021

10 .6-13

SC9000 CI Variable Frequency Drive—Medium Voltage

EATON www.eaton.com

Application Details

Page 14: New SC9000 CI variable frequency drive— medium voltage · 2021. 4. 5. · 1250 hp in a 65-inch wide enclosure. Based on the proven SC9000 design, the CI drive allows for output

Frame Size Variable (VT) Reference ChartTable 10.6-3. SC9000 CI Frame ASee Figure 10 .6-2.

2400/60 Hz VT 4160/60 Hz VT

FLA hp FLA hp

  69  80  91

300350400

  38  44  51

  300  350  400

103114134

450500600

  57  63  76

  450  500  600

156178—

700800—

  89101114

  700  800  900

———

———

124132155

1000 1150 1250

VT = Variable Torque (110% overload for 1 minute every 10 minutes)

Table 10.6-4. SC9000 CI Adjustable Frequency Drive Efficiency, Power Factor and Harmonics Typical Data Description Load (%)

50 75 100

Speed 50%Input PF (1) 0.96 0.98 0.98

Input THD (V) 3.13 3.64 3.43

Input THD (I) 7.59 6.40 6.73

Efficiency (%) 0.943 0.959 0.962

Speed: 75%Input PF (1) 0.98 0.99 0.99

Input THD (V) 1.34 2.32 3.15

Input THD (I) 6.76 4.44 3.85

Efficiency (%) 0.965 0.970 0.971

Speed: 100%Input PF (1) 0.98 0.99 0.99

Input THD (V) 2.16 2.20 2.30

Input THD (I) 5.95 4.38 3.13

Efficiency (%) 0.971 0.972 0.974

Table 10.6-5. SC9000 CI Adjustable Frequency Drive Heat Loss Data a

Horsepower Watts Loss as Heat

Horsepower Watts Loss as Heat

200    4600   900 20,700

300    6900 1000 23,000

350    8050 1250 28,750

400    9200 — —

450 10,350 — —

500 11,500 — —600 13,800 — —

700 16,100 — —

800 18,400 — —

a Estimate additional 2 watt/hp heat loss for DVDT or sine filter (see IB20002EN for more details).

Design Guide DG020006EN Effective March 2021

10 .6-14

SC9000 CI Variable Frequency Drive—Medium VoltageApplication Details

EATON www.eaton.com

Page 15: New SC9000 CI variable frequency drive— medium voltage · 2021. 4. 5. · 1250 hp in a 65-inch wide enclosure. Based on the proven SC9000 design, the CI drive allows for output

Typical Schematic

Figure 10.6-10. Typical Schematic for SC9000 CI VFD

Design Guide DG020006EN Effective March 2021

10 .6-15

SC9000 CI Variable Frequency Drive—Medium VoltageApplication Details

EATON www.eaton.com

Page 16: New SC9000 CI variable frequency drive— medium voltage · 2021. 4. 5. · 1250 hp in a 65-inch wide enclosure. Based on the proven SC9000 design, the CI drive allows for output

Figure 10.6-11. Typical Schematic for 24-Pulse Transformer, Rectifier and Inverter

TX TY

PE LI

GHT

CUST

OMER

CON

N.

INTE

RNAL

TERM

. BLK

(S)

TERM

. BLK

. FOR

REM

OTE D

EVIC

E = = = =

* TX =IN

PUT

MCX

EXAM

PLE:

MOD

ULE #

DRIV

E I/O

O1A

KEYP

AD G

RAPH

ICS D

ISPLA

YM

OUNT

ED O

N DO

OR

STAR

Tre

set

STOP

loca

lfa

ult

rem

ote

ente

r

UPU U P L UNU LNU UPW LPW

LNWUNWLNVUNVLPVUPV

MITG

PS

CONN

ECTO

RDB

-9KE

YPAD

J2J4 X2X0 S0 S2X3X1 S1 S3

Y0 C0 Y1 C1

C2 Y2 C3 Y3

765 8234 1

24V

0VGND

PCR

MCR

MRR

AUX 0V 24

V 0V 24V

-15V

+3.3V

DIN

2D

IN3

+15V +5

V

DIN

1D

IN4 (LE

D LIG

HTS)

+5V I

SOUN

DER

+24V

POWE

R FAIL

AUX

MRR

MCR

PCR

INPU

TDRIV

E MOT

ORDM

CRCO

NTRO

L RAC

K

J3

MP3 MP2 MP1

TX1

RX1 CH CL TX2

RX2

TX3

RX3

TX4

RX4

SITG

SITG

CARD

USE

D W

ITH D

UAL

POW

ER PO

LE

INVE

RTER

S

loc/

rem

VOLTA

GE

GND

T1

(NEG

)

(NEU

T)

(POS

)

24

PR D1

D2

D3

F1 F2 F3 F6F5F4 F9F8F7 F12

F11

F10

24 PU

LSE

RECT

IFIER

D6

D5

D4

D9

D8

D7

D12

D11

D10

N

(+)

700 A

MP

TYPI

CAL

DC

LIN

K

1R1

1S1

1T1

2R1

2T1

2S1

3R1

3T1

3S1

4R1

4T1

4S1

D1-6

D7-1

2

POS

NEUT

NEG

W1C

T

V1CT

U1CT

RED

WHT

BLK

+M

-

M

-

+

+

-M

W1

V1U1

WPLDD

5

UPU

VPU

VPL

UPL

DD1

DD3

C2C1Q1

Q5

Q2Q6

Q10

C G EW

PUQ9

EGC

EGC

EGC

C G E

C G E

Q8UN

LVN

LEGC

86

457

9

DD6

DD4

DD2

UNU

VNU

Q7Q3

C G E

C G E

Q12

Q11

WNL

C G E

WNU

EGC

IGBT

2L2

2L1

2L3

H3 H2 H1 H01

23

45

67

89

VW

U

RED

WHT

BLK

RED

WHT

BLK

RED

WHT

BLK

GND

S4 T4R4S3 T3R3S2 T2R2T1S1R1

24 PU

LSE R

ECITF

IER

+22.5

-7.5

+7.5

-22.5

INV

ERTE

RIN

V

W1

V1U1

CABL

ES R

OUTE

DTO

DRI

VE

OUTP

UT

SEE D

WG

S01

DMCR

MITG

Q4EGC

86

457

9

RED

WHT

BLK

RED

WHT

BLK

86

457

9

86

457

9

86

457

986

457

9

86

457

9

86

457

986

457

9

86

457

9

86

457

9 86

457

9M

P2

0v 0v+15V

VunR

MS

VnnA

VG

-15V Vneg

VnnR

MS

874 62 3 51

MP3

DMCR

MITG TF

1TF

2

MAI

N TR

ANSF

ORM

ER TE

MP S

WITC

HS

1B1A

1CXT

F

BLK

XFM

R TEM

P FAU

LTW

HT

1CI3

B

TF4

MAI

N TR

ANSF

ORM

ER TE

MP S

WITC

H

2A2B

XTA

BLK

XFM

R TEM

P AM

BIEN

TW

HT

2BI4

A

200 C

60 C

WIR

E CO

NNEC

TION

GND

J18+

12

PHAS

E

J17+

12

PHAS

EPH

ASE2

1J1

6+

WV

UPOS

VPOS

WPO

S

J18-

12

PHAS

E

J17-

12

PHAS

EPH

ASE

21

J16-

WV

UNEG

VNEG

WNE

G

URTD

URTD

II-02

URTD

URTD

II-02

URTD

URTD

II-02

URTD

URTD

II-02

URTD

URTD

II-02

URTD

URTD

II-02

9

Vpos

J1 CONNECTOR

RED

WHT

BLK

RED

WHT

BLK

RED

WHT

BLK

R2R1

R4R3

RN

J5

24VD

C10

A

14 1513PX PX PX

XFM

RCOI

L TE

MPE

RATU

RE

A1A

RTD5

BLK

WHT

A1-1

A1-2

DMCR

OPT

ION

BOAR

DSM

OUNT

ED U

NDER

SPX

DRIV

E

FOR C

ONTR

OLLE

R SET

TNGS

SEE W

IRIN

G DI

AGRA

MS

7654321 8M

P19

DMCR

MITG

AMBI

ENT

TEM

PERA

TURE

ON

INLE

T FI

LTER

RTD2

TEM

PERA

TURE

INSID

E CAB

INET

RED

WHT

RTD1 RE

D

WHT

RED

GRN

WHT

BLK

RED

BLK

T1 T2

GNDW

HT

GRN

T3 T4RT

DTB

RED

WHT

RED

WHT

1 2 3 4 5 6 7 8

RTD1

RTD2

VOLT

AGE

FEED

BACK

BO

ARD

NEG

NEU

POS

+BUS

-BUS NE

U

VFB

XFM

R

1114

2321

1311

141211

Design Guide DG020006EN Effective March 2021

10 .6-16

SC9000 CI Variable Frequency Drive—Medium VoltageApplication Details

EATON www.eaton.com

Page 17: New SC9000 CI variable frequency drive— medium voltage · 2021. 4. 5. · 1250 hp in a 65-inch wide enclosure. Based on the proven SC9000 design, the CI drive allows for output

Eaton1000 Eaton BoulevardCleveland, OH 44122United StatesEaton .com

© 2021 EatonAll Rights ReservedPrinted in USAPublication No . DG020006EN / Z24824March 2021

Eaton is a registered trademark.

All other trademarks are property of their respective owners.

SC9000 CI Variable Frequency Drive—Medium Voltage

Design Guide DG020006EN Effective March 2021

10 .6-17