2
Contents
General dataPerformance range page 4Product range page 6
- to successfully develop, produce, and sell high quality pumps and pumping systems worldwide, contributing to a better quality of life and healthier environment
• One of the 3 largest pump companies in the world
• World headquarters in Denmark
• North American headquarters in Kansas City - Manufacturing in Fresno, California
• 60 companies in 40 countries
• More than 10 million pumps produced annually worldwide
• North American companies operating in USA, Canada and Mexico
• Continuous reinvestment in growth and development enables the company to
BE responsible, THINK ahead, and INNOVATE
This page intentionally left blank.
5
Performance range
Notes:1MTA(D) and MTC products are not available in Canada.2Pumps supplied by Grundfos Canada are normallysupplied with motors from other manufacturers. 575Vmotors meet EPAct/NRC efficiency standards. Dimen-sions and data will vary slightly. Contact local Grundfoscompany for more information.
Variable speed motor (</=10 hp) z * z * z * z * z * z * z * z * z ***With extension pipe1 - Standard for >5 impellers2 - Standard for >8 impellers
A
B
General data Immersible pumps
8
General data MTA(D)
Performance range
Note: MTA(D) pumps are not available in Canada.
TK0
1 8
553
400
2
0 20 40 60 80 100 120 140 Q [US GPM]
0
5
10
15
20
25
30
35
40
45
H [ft]
0 5 10 15 20 25 30 35 Q [m³/h]
0
2
4
6
8
10
12
14
H [m]
MTA / MTAD60 Hz
MTA 3
MTA 4
MTAD 7 MTAD 7 1 outlet 2 outlets
9
Product descriptionThe MTA pumps are designed for pumping of coolinglubricants for machine tools, condensate transfer andother similar applications.
MTA pumps are suitable for applications involving elec-trical discharge machine tools, grinding machines,machining centers, cooling units, industrial washingmachines, filtering systems, etc.
The pumps feature ...
• low pressure
• open impeller
• filled PTFE bearing for high vibration resistance
• stainless steel impeller and shaft
• easy installation.
In addition, the two separate outlets of the MTAD two-chamber pump allow for high flexibility and ease of usein applications requiring flows different places.
Pumped liquidsThe pumps are suitable for pumping non-explosiveliquids, including water and water-soluble coolants andcutting lubricants.
PumpThe MTA pumps are one-chamber or two-chambercentrifugal pumps, of which the latter type, MTAD, hastwo separate outlets. Mounting flange dimensions areaccording to DIN 5440/JEM 1242.
MotorThe pump is fitted with a totally enclosed, fan-cooledmotor.
Enclosure type: TEFC (IP 54)Insulation class: F
Standard voltages
Other voltages are available on request.
MTAD 7/7 is available with plug connector, HAN 10 ES,on request.
Three-phase motors must be connected to a motorstarter in accordance with local regulations.
Operating conditionsLiquid temperature: +14°F to +194°F
Ambient temperatureMaximum +104°F (+40°C).
If the ambient temperature exceeds +104°F (+40°C) or ifthe motor is located 3280 ft. (1000 m) above sea level,the motor output (P2) must be reduced due to the lowdensity and consequently low cooling effect of the air. Insuch cases, it may be necessary to use a motor with ahigher output.
Example:From the above figure appears that P2 must be reducedto 88% when the pump is installed 11,000 ft (3500 m)above sea level. At an ambient temperature of 156°F(70°C), P2 must be reduced to 80% of rated output.
Sound pressure level
Motor 60 Hz
0.33 HP 3 x 208-277/360-480 V
0.60 HP 3 x 208-277/360-480 V
2.00 HP 3 x 208-266/360-460 V
TK0
0 2
189
370
2
Motor [hp]dB(A)
60 Hz
0.33 <70
0.60 <70
2.00 <70
70 80 90 100 110 120 130 140 150 160 170 180
50
60
70
80
90
100
[%]P2
t [˚F]3280 7380 11480 ft
General data MTA(D)
10
Technical data MTA(D)
Type keyThe pump key on the pump nameplate indicateswhether the pump is a one-chamber or two-chamberpump. The pump nameplate also indicates flow rate andinstallation length.
Curve conditionsThe performance curves are based on the folllowingconditions:
Pumped liquid
Installation
The MTA pump is designed for vertical mounting in atank.
The distance between the bottom of the pump and thebottom of the tank must be at least 3/8” (10 mm). Thepumps are designed to provide full performance downto a level of L in. above the bottom of the pump, seebelow.
MTA 3, MTA 4
MTAD 7/7
Maximum liquid level
To protect the motor from the pumped liquid, themaximum liquid level in the installation tank must be 3/4”below the top of the tank. See the figure below.
Example MT A D 7/7 - 250
Pump range(Machine Tool)
Product type
Two-chamber pump
Nominal flow rate[m³/h]
Installation length [mm]
If the kinematic viscosity is ... the test liquid is ...
υ = (1 cSt)1 mm²/s Airless water of a temperature of 68° F (20° C)
TM0
1 85
22 0
300
MTA 3 MTA 4
L [in] 1 3/8” 1 3/4”
TM0
1 86
57 0
60
0TM
01
86
58 0
60
0TM
01
90
76 1
00
0
3/8"
L
3/8"
5"
1 3/4"
Min. 3/4"
11
Technical data MTA(D)
Materials
Sectional drawing MTA 3, MTA 4 Sectional drawing MTAD 7/7
Pos. Description Materials AISI/ASTM
2 Motor stool Cast iron ASTM 30 B
6 Pump housing lower Cast iron ASTM 30 B
6b Pump housing upper Cast iron ASTM 30 B
28 Hexagon socket head screw Stainless steel AISI 304
47 Bearing Filled PTFE -
47d Retaining ring Stainless steel -
48 Split cone nut Stainless steel AISI 316
49 Impeller Stainless steel AISI 316
49b Split cone Stainless steel AISI 304
84 Strainer, 3/16” holes Stainless steel AISI 304
84b Hexagon socket head screw Stainless steel AISI 304
105 Diverting disc NBR
TM0
1 8
535
260
0
105
49b
49
48
47d
47
84b
2
6
84
TM0
1 9
676
26
00
105
49
28
47
49b
48
4747d
49b
48
84b
2
6
6b
84
12
Technical data MTA 3
Performance curves
Dimensional sketches Electrical data
TM0
1 8
583
470
0
60 Hz
Supply voltage 3 x 208-277/360-480V
Motor P1 [W] 320
Maximum current [A] 1.2/0.7
Full load current [A] 1.0/0.6
Weight [lb] 19.2
Connections 3/4” NPT
Product number 96433135
50 Hz
Supply voltage 3 x 220-240/360-480V
Motor P1 [W] 220
Maximum current [A] 1.1/.65
Full load current [A] 0.9/0.5
Weight [lb] 19.2
Connections 3/4” NPT
Product number 96433135
ø 3 7/8"
2 13
/16"
ø 3 15/16"
ø 4 5/8"
15"
7 1/
8"
1"
5 11
/16"
5 11/16"
3 13/16"
ø 3/8"ø 5/16"
ø 4 9/16"ø 6 5/16"
3/4" NPT
TK0
1 81
34 1
103
0 5 10 15 20 25 30 35 Q [US GPM]
0
10
20
30
H [ft]
0 1 2 3 4 5 6 7 8 Q [m³/h]
0
5
10
H [m]
MTA 3-18060 Hz
3400 RPM
0 5 10 15 20 25 30 35 Q [US GPM]
0.32
0.36
0.40
0.44
[hp]P1
0
10
20
30
[%]Eta
0.24
0.28
0.32
P1[kW]
P1
Eta
13
Technical data MTA 4
Performance curves
Dimensional sketches Electrical data
TM0
1 8
584
470
0
60 Hz
Supply voltage 3 x 208-277/360-480V
Motor P1 [W] 560
Maximum current [A] 1.8/1.05
Full load current [A] 1.65/0.95
Weight [lb] 23.1
Connections 3/4” NPT
Product number 96433136
50 Hz
Supply voltage 3 x 220-240/380-415V
Motor P1 [W] 360
Maximum current [A] 1.45/.85
Full load current [A] 1.30/0.75
Weight [lb] 23.1
Connections 3/4” NPT
Product number 96433136ø 4 11/16"
9 7/
8"
17 3
/4"1"
3/4" NPT
3"
ø4 3/4"
ø 4 5/8"
5 15
/16"
3 13/16"
ø 3/8"
ø 6 5/16"
5 5/16"
TK0
1 81
37 1
103
0 5 10 15 20 25 30 35 40 45Q [US GPM]
0
10
20
30
40
H [ft]
0 1 2 3 4 5 6 7 8 9 10 Q [m³/h]
0
5
10
[m]
MTA 4-25060 Hz
3400 RPM
0 5 10 15 20 25 30 35 40 45Q [US GPM]
0.5
0.6
0.7
0.8
[hp]P1
0
10
20
30
[%]Eta
0.4
0.5
0.6
P1[kW]
P1
Eta
14
Technical data MTAD 7/7
Performance curves
Dimensional sketches Electrical data
TM0
1 8
585
470
0
60 Hz
Supply voltage 3 x 208-277/360-480V
Motor P1 [W] 1600
Maximum current [A] 5.7/3.3
Full load current [A] 5.4/3.1
Weight [lb] 53.8
Connections 1 1/4” NPT
Product number 96433137
TK0
1 81
40 1
103
ø 5 7/16"
ø 5 9/16"
3 15/16"
ø 5 5/8"
1 1/
4"
20 7
/8"
9 7/
8"
ø 7/16" 7 7/8"
ø 8 11/16"
ø 6 5/16"
ø 3/8"
4 5/16"
1 1/4" 1 1/4"
0 20 40 60 80 100 120 140 Q [US GPM]
0
10
20
30
40
H [ft]
0 5 10 15 20 25 30 35 Q [m³/h]
0
5
10
H [m]
MTAD 7/7-25060 Hz
3400 RPM
1 outlet 2 outlets
0 20 40 60 80 100 120 140 Q [US GPM]
1.2
1.4
1.6
1.8
2.0[hp]P1
0
10
20
30
40[%]Eta
1.0
1.2
1.4
P1[kW] P1
Eta
This page intentionally left blank.
16
General data MTC
Performance range
Note: MTC pumps are not available in Canada.
TK0
1 44
62
260
22 4 6 8 10 20 40 60 80 100 Q [US GPM]
5
10
20
30
50
100
200
300
500
H [ft]
11 2 3 4 5 6 7 8 9 1010 20 30 Q [m³/h]
2
4
68
10
20
40
6080
100
200H [m]
MTC60 Hz
MTC 2 MTC 4
MTC 8
MTC 16
MTC 12
17
General data MTC
Product range MTC 2
Product range MTC 4
Product range MTC 8
Product range MTC 12
Product range MTC 16
Example: MTC 2-60/6Number of impellers B
[in]1 2 3 4 5 6
Nu
mb
er o
f ch
amb
ers
x 10
30 z z z 5 3/4
40 z z z z 6 7/16
50 z z z z z 7 1/8
60 z z z z z z 7 7/8
90 z z z z z z 10
100 z z z z z z 10 11/16
110 z z z z z z 11 7/16
Motor [hp] 1/4 1/2 3/4 1 1 1/5 1 2/5
Example: MTC 4-60/4Number of impellers B
[in]1 2 3 4
Nu
mb
er o
f ch
am
ber
s x
10
20 z z 5 3/4
30 z z z 6 13/16
40 z z z z 7 7/8
50 z z z z 8 15/16
60 z z z z 10
70 z z z z 11 1/16
80 z z z z 12 1/8
Motor [hp] 1/2 9/10 1 3/10 1 3/4
Example: MTC 8-60/6Number of impellers B
[in]2 3 4 5 6 7
Nu
mb
er o
f ch
amb
ers
x 10
20 z 2 3/8
30 z z 3 9/16
40 z z z 4 3/4
50 z z z z 5 15/16
60 z z z z z 7 1/8
70 z z z z z z 8 5/16
Motor [hp] 2 3 5 5 7 1/2 7 1/2
BB
BB
B
Example: MTC 12-60/3Number of impellers B
[in]2 3
Nu
mb
er o
f ch
amb
ers
x 1
0
20 z 2 3/8
30 z z 3 9/16
40 z z 4 3/4
50 z z 5 15/16
60 z z 7 1/8
70 z z 8 5/16
Motor [hp] 5 7 1/2
Example: MTC 16-50/3Number of impellers B
[in]2 3
Nu
mb
er o
f ch
amb
ers
x 10
20 z 3
30 z z 4 3/4
40 z z 6 1/2
50 z z 8 5/16
60 z z 10 1/16
Motor [hp] 5 7 1/2
B
B
18
General dataT
MTC
Product descriptionMTC is designed for pumping cooling lubricants formachine tools, condensate transfer and other purposes.
MTC is specially designed for applications offering onlylimited space for installation. Motor and pump form anintegral, compact unit consisting of few components.The pump is designed for medium pressure.
The pump can be used for applications involving lathes,grinding machines, machining centres, cooling units,industrial washing machines, filtering systems, swarfconveyors etc.
Pumped liquidsThin, clean, non-explosive liquids without abrasiveparticles or fibers. Both water and water-soluble cool-ants and cutting lubricants can be pumped.
PumpThe pump is a multistage, centrifugal pump withmechanical shaft seal. Mounting flange sizes accordingto DIN 5440. To meet specific depths of tanks orcontainers, the installation length of the pump can bevaried using empty chambers. Available variants arebased on the number of stages indicated in the dimen-sions and weights tables.
MotorThe pump is fitted with a totally enclosed, fan-cooledmotor.
Enclosure type: TEFC (IP 54)Insulation class: FStandard voltages, 60 Hz: 3 x 208 - 230/460 V
Three-phase motors must be connected to a motorstarter in accordance with local regulations.
Operating conditionsLiquid temperature:
MTC 2/4 +32°F to +194°FMTC 8/12/16 +14°F to +194°F
Ambient temperatureMaximum +104°F (+40°C).
If the ambient temperature exceeds +104°F (+40°C) or ifthe motor is located 3280 ft. (1000 m) above sea level,the motor output (P2) must be reduced due to the lowdensity and consequently low cooling effect of the air. Insuch cases, it may be necessary to use a motor with ahigher output.
Example:From the above figure appears that P2 must be reducedto 88% when the pump is installed 11,000 ft (3500 m)above sea level. At an ambient temperature of 156°F(70°C), P2 must be reduced to 80% of rated output.
Sound pressure level
Shaft sealMax. operating pressure and liquid temperature for theshaft seal.
TK0
0 2
189
370
2
Motor P1 [W] dB(A)340 <70
505 <70
540 <70
740 <70
870 <70
980 <70
1155 <70
1250 <70
1365 <70
1600 <70
1805 <70
2500 - 5377 71TK
01
160
2 40
02
70 80 90 100 110 120 130 140 150 160 170 180
50
60
70
80
90
100
[%]P2
t [˚F]3280 7380 11480 ft
-40 0 40 80 120 160 200 240
0
100
200
300 AUUV
t [˚F]
p[psi]
19
General dataT
MTC
Type key Installation
If the MTC 2/4 pump is installed horizontally, the motorstool drain hole must be closed with a 1/8 in. pipe plug.
To enable a very low liquid level of 1 1/2 in. (37mm) forMTC 2/4 and 1 5/8 in. (40mm) for MTC 8/12/16 above thebottom of the strainer, a priming screw is fitted belowthe bottom intermediate chamber. This protects thepump against dry running down to 7/8 in. (22mm) forMTC 2/4 and 1 in. (25mm) for MTC 8/12/16 above thebottom of the strainer.
Distance between pump and tank bottom must beminimum 1 inch (25mm).
Example MTC 4 - 50 / 3 U - W - A AUUV
Pump type
Nominal flow [m³/h]
No. of chambers x 10
Number of impellers(ref. to performance curveand motor size)
Pump versionU: NEMA
Connection codeW: internal thread
MaterialsA : Basic
Shaft seal A U U VA: O-ring seal with fixed driver
Product descriptionSPK/CRK are designed for pumping cooling lubricantsfor machine tools, condensate transfer and otherpurposes.
The pumps are designed for low to high pressure and arevery flexible as to installation length.
The pumps can be used for applications involving EDMmachine tools, grinding machines, machining centers,cooling units, industrial washing machines, filteringsystems etc.
Pumped liquidsThin, clean, non-explosive liquids without abrasiveparticles or fibers. Both water and water-soluble cool-ants and cutting lubricants can be pumped.
PumpThe pump is a multistage, centrifugal pump with amechanical shaft seal. Mounting flange sizes accordingto DIN 5540. To meet specific depths of tanks orcontainers, the installation length of the pump can bevaried using empty chambers and/or an extension pipe.
Available variants are based on the number of stagesindicated in the dimensions and weights tables.
Example: An SPK 1 pump with 8 impellers is availablewith installation lengths from SPK 1-8 to SPK 1-23(dimension B). Note: Empty chambers may cause pressure loss.
I-versionAs standard the SPK/CRK pumps are available as I-version called SPKI/CRKI. All parts of SPKI/CRKI pumps incontact with the pumped liquid are made of stainlesssteel AISI 316 or 316LN.
MotorElectrical Data
Other voltages available on request.
Operating conditionsLiquid temperature: +14°F to +194°F (-10°C to +90°C).
Ambient temperatureMaximum +104°F (+40°C).
If the ambient temperature exceeds +104°F (+40°C) or ifthe motor is located 3280 ft. (1000 m) above sea level,the motor output (P2) must be reduced due to the lowdensity and consequently low cooling effect of the air. Insuch cases, it may be necessary to use a motor with ahigher output.
Example:From the above figure appears that P2 must be reducedto 88% when the pump is installed 11,000 ft (3500 m)above sea level. At an ambient temperature of 156°F(70°C) P2 must be reduced to 80% of rated output.
Sound pressure level
Shaft sealMax. operating pressure and liquid temperature
Mounting designation NEMA
Insulation class F
Efficiency class
Standard Efficiency
EPAct - on request
High Efficiency - on request
Enclosure classODP - Open Drip ProofTEFC - Totally Enclosed Fan Cooled
60 HzStandard voltages
1 x 115/208-230
3 x 208-230/460
3 x 575
TK0
0 2
189
370
2
Motor [hp] dB(A)
1/3 to 1 1/2 <70
2 to 5 71
7.5 78
10 78
15 84
20 77TK
01
160
1 39
02
70 80 90 100 110 120 130 140 150 160 170 180
50
60
70
80
90
100
[%]P2
t [˚F]3280 7380 11480 ft
-40 0 40 80 120 160 200 240
0
100
200
300AUUV
t [˚F]
p[psi]
36
General data SPK/CRK
Type key SPK Type key CRK
Example SPK 2 - 15 / 8 U - W - A AUUV
Pump type
Nominal flow [m³/h]
No. of chambers
No. of impellers(ref. to performancecurve and motor size)
Pump versionU: NEMAL : With extension pipe
Connection codeW: Internal thread
MaterialsA : BasicI : Motor stool in stainless steel
Shaft seal A U U VA: O-ring seal with fixed driver
U: Cemented tungsten carbide
V: FKM
Example CRK 4 - 120 / 8 U - W - A AUUVPump type
Nominal flow [m³/h]
Number of chambers x 10
Number of impellers(ref. to performancecurve and motor size)
Pump versionU: NEMAL : With extension pipe
Connection codeW: Internal thread
MaterialsA : BasicI : Motor stool in stainless
Shaft seal A U U VA: O-ring seal with fixed driver
U: Cemented tungsten carbide
V: FKM
37
General data SPK/CRK
Extension pipeAll SPK pumps are available with an extension pipe. Theextension pipe is available in various lengths enablinginstallation lengths up to 39 5/8 in. (1005 mm).
CRK 2 and CRK 4 pumps can be extended by means ofempty chambers enabling installation lengths up to 395/8 in. (1005 mm).
SPK, CRK 2/4 Installation
If the SPK pump is installed horizontally, the motor stooldrain hole must be closed.
CRK 8/16 Installation
SPK and CRK 2/4
CRK 8/ 16
The pumps are designed to provide full performancedown to a level of A in. above the bottom of the strainer.
At a liquid level between A and B in. above the bottom ofthe strainer, the built-in priming screw will protect thepump against dry running.
TM0
1 42
14 1
299
TM0
0 1
922
329
7
Extension pipeor extensionchambers
TM0
0 1
924
329
7TM
01
7810
38
01
TM0
1 78
11 4
899
Pump type A [in] B [in]
SPK and CRK 2/4 1 5/8 1
CRK 8/16 2 1
CRK 8/16 are designed for vertical mountingin a tank.
* The stated weights apply to CRK only. For CRKI, add 3 lbs.
HP PHNEMAFrame
ServiceFactor
VoltageMotorEff. [%]
Insul. Class KVA CodeFull Load
Current [A]Service Factor
Current [A]Start
Current [A]
2 1
3
3
56C
56C
56C
1.15
1.15
1.15
115/230
208-230/460
575
74
80
80
F
F
F
K
H
H
23/11.5
5.7-5.4/2.7
2.2
25.8/12.9
6.5-6.2/3.1
2.5
156/78
38.7-35/17.5
14
5 1
3
3
213TC
184TC
184TC
1.15
1.15
1.15
230
208-230/460
575
80
85
85
F
F
F
J
K
K
22
13.2-12/6.0
4.8
25
15-13.6/6.8
5.4
170
103.9-94/47
38
7 1/2 1
3
3
213TC
213TC
213TC
1.15
1.15
1.15
208-230
208-230/460
575
82
87
87
F
F
F
F
L
L
34.3-31
19-17.2/8.6
6.9
39.3-35.5
21.7-19.6/9.8
8.5
240-217
168.1-152/76
61
10 1
3
3
213TC
213TC
213TC
1.15
1.15
1.15
230
208-230/460
575
88.5
85.5
85.5
F
F
F
F
J
J
40
25-24/12
9.6
46
28.7-27.6/13.8
11
233.5
232.2-210/105
84
15 3
3
254TC
254TC
1.15
1.15
208-230/460
575
86.5
86.5
F
F
L
L
38-34/17
13.6
43.6-40/20
16
376-340/170
136
20 3
3
254TC
284TSC
1.15
1.15
230/460
575
88.5
90.2
F
F
K
H
46/23
19
52.4/26.2
21.4
420/210
138
1All specifications are for TEFC motors. ODP motors are available on request. For pumps supplied from Grundfos Canada. See Note 2 on page 5.
58
Loss curves for CRK 8 and CRK 16
Pressure loss in pumps with empty chambers
In pumps with empty chambers, there will be one or twochambers with a bearing. These chambers will have apressure loss which must be deducted from the perform-ance curves. The pressure loss can be found on thecurves below.
The number of empty chambers with bearing is found inthe table at the bottom of the page.
Curve 1 = Pumps with one empty chamber with bearing
Curve 2 = Pumps with two empty chambers with bearing
Pumps with empty chambers
TK0
0 4
386
020
3
0 10 20 30 40 50 Q [US GPM]
0
5
10
15
20
H[ft]
0 2 4 6 8 10 12 Q [m³/h]
0
2
4
6
H[m] CRK 8
2
1
TK0
0 4
387
020
3
0 20 40 60 80 Q [US GPM]
0
10
20
30
40
H[ft]
0 5 10 15 20 Q [m³/h]
0
5
10
H[m] CRK 16
2
1
No. ofimpellers
(x)
Number of empty chambers with bearing in pumps with empty chambers
Product descriptionMTR is designed for pumping cooling lubricants formachine tools, condensate transfer and other purposes.
MTR is a strong and sturdy pump, designed for mediumto high pressure and large flows.
The pumps can be used for applications involving sparkmachine tools, grinding machines, machining centers,cooling units, industrial washing machines, filteringsystems etc.
Pumped liquidsThin, clean, non-explosive liquids without abrasiveparticles or fibers. Both water and water-soluble cool-ants and cutting lubricants can be pumped.
PumpThe pump is a multistage, centrifugal pump withmechanical shaft seal. Mounting flange sizes accordingto DIN 5440. To meet specific depths of tanks orcontainers, the installation length of the pump can bevaried using empty chambers.
Motor
Electrical data
Other voltages available on request.
Motor protection
Single-phase motors have a built-in thermal overloadswitch.
Three-phase motors must be connected to a motorstarter in accordance with local regulations.
Operating conditionsLiquid temperature: -4°F to +194°F (-20°C to +90°C).
Ambient temperatureMaximum +104°F (+40°C).
If the ambient temperature exceeds +104°F (+40°C) or ifthe motor is located 3280 ft. (1000 m) above sea level,the motor output (P2) must be reduced due to the lowdensity and consequently low cooling effect of the air. Insuch cases, it may be necessary to use a motor with ahigher output.
Example:From the above figure appears that P2 must be reducedto 88% when the pump is installed 11,000 ft (3500 m)above sea level. At an ambient temperature of 156°F(70°C), P2 must be reduced to 80% of rated output.
Sound pressure level
Shaft sealMax. operating pressure and liquid temperature for theshaft seal.
Mounting designation NEMA
Insulation class F
Efficiency class
Standard Efficiency
EPAct - on request
High Efficiency - on request
Enclosure classODP - Open Drip Proof
TEFC - Totally Enclosed Fan Cooled
60 HzStandard voltages
1 x 115/208-230
3 x 208-230/460
3 x 575
TK0
0 2
189
370
2
Motor [hp]dB(A)
60 Hz
3 71
5 71
7 1/2 78
10 78
15 84
20 77
25 77
30 75
40 84
TK0
1 16
04
400
2
70 80 90 100 110 120 130 140 150 160 170 180
50
60
70
80
90
100
[%]P2
t [˚F]3280 7380 11480 ft
-40 0 40 80 120 160 200 240
0
100
200
300
400
p[psi]
EUUV
HUUV
t [˚F]
63
General data MTR
Type key Installation
The pumps are designed to provide full performancedown to a level of 2-3/4 ” (70 mm) above the bottom ofthe strainer.
Distance between pump and tank button must beminimum 1” (25 mm).
Example MTR 32 -2 / 1 -1 -U -F -A EUUV
Pump type
Nominal flow [m³/h]
Number of chambers
No. of impellers
No. of impellerswith reduceddiameter
Pump versionU: Nema
Connection codeF: ANSI flange
MaterialsA : Basic
Shaft seal E U U V
E: Cartridge seal with o-ring
H: Balanced cartridge seal
U: Cemented tungsten carbide
V: FKM
TM0
1 49
90
139
9TM
01
780
8 48
99
MTR pumps aredesigned forvertical mountingin a tank.
1"
2 3/4"
64
General data MTR
Materials, MTR
Pos. Description Materials AISI/ASTM
1a Motor stool Cast iron ASTM 25B
2 Pump head Cast iron ASTM 80-55-06
3 Intermediate chamber with guide vanes Stainless steel AISI 304
3a Intermediate chamber without neck ring Stainless steel AISI 304
4 Chamber complete Stainless steel AISI 304
4a Intermediate chamber with bearing Stainless steel AISI 304
7 Coupling guard Stainless steel AISI 430
7a Screw Stainless steel AISI 304
7c Screw Stainless steel AISI 304
8a Coupling
9 Screw Steel
26a Strap Stainless steel AISI 304
28 Hexagon head screw Steel
28a Hexagon head screw Steel
36 Nut Steel
36a Nut Steel
44 Inlet part Stainless steel AISI 304
45 Neck ring Carbon-graphite filled PTFE
45a Neck ring complete Stainless steel AISI 304
47 Bearing ring Bronze
47a Intermediate bearing with seal driver Stainless steel AISI 316
33 182TC 1.15 208-230/460 82 F K 8.2-7.8/3.9 9.2-8.8/4.4 77.4-70/35
182TC 1.15 575 82 F K 3.1 3.5 28
53 184TC 1.15 208-230/460 85 F K 13.2-12/6.0 15-13.6/6.8 103.9-94/47
3 184TC 1.15 575 85 F K 4.8 5.4 38
7 1/23 213TC 1.15 208-230/460 87 F L 19-17.2/8.6 21.7-19.6/9.8 168.1-152/76
3 213TC 1.15 575 87 F L 6.9 8.5 61
103 213TC 1.15 208-230/460 85.5 F J 25-24/12 28.7-27.6/13.8 232.2-210/105
3 213TC 1.15 575 85.5 F J 9.6 11 84
153 254TC 1.15 208-230/460 86.5 F L 38-34/17 43.6-40/20 376-340/170
3 254TC 1.15 575 86.5 F L 13.6 16 136
203 254TC 1.15 230/460 88.5 F K 46/23 52.4/26.2 420/210
3 284TSC 1.15 575 90.2 F H 19 21.4 138
253 284TSC 1.15 230/460 88.5 F J 58/29 69.4/34.7 496/248
3 284TSC 1.15 575 88.5 F J 23.7 27.8 198.4
303 286TSC 1.15 230/460 91.7 F G 66/33 77.2/38.6 448/224
3 284TSC 1.15 575 91 F G 27.5 31.5 172
403 284TSC 1.15 230/460 90.2 F G 94/47 105.2/52.6 580/290
3 326TSC 1.15 575 F
1All specifications are for TEFC motors. 1-phase (up to 10HP) and ODP motors are available on request. For pumps supplied from Grundfos Canadasee Note 2 on page 5.
7 1/23 213TC 1.15 208-230/460 87 F L 19-17.2/8.6 21.7-19.6/9.8 168.1-152/76
3 213TC 1.15 575 87 F L 6.9 8.5 61
153 254TC 1.15 208-230/460 86.5 F L 38-34/17 43.6-40/20 376-340/170
3 254TC 1.15 575 86.5 F L 13.6 16 136
203 254TC 1.15 230/460 88.5 F K 46/23 52.4/26.2 420/210
3 284TSC 1.15 575 90.2 F H 19 21.4 138
253 284TSC 1.15 230/460 88.5 F J 58/29 69.4/34.7 496/248
3 284TSC 1.15 575 88.5 F J 23.7 27.8 198.4
303 286TSC 1.15 230/460 91.7 F G 66/33 77.2/38.6 448/224
3 284TSC 1.15 575 91 F G 27.5 31.5 172
403 284TSC 1.15 230/460 90.2 F G 94/47 105.2/52.6 580/290
3 326TSC 1.15 575 F
1All specifications are for TEFC motors. 1-phase (up to 10HP) and ODP motors are available on request. For pumps supplied from Grundfos Canadasee Note 2 on page 5.
7 1/23 213TC 1.15 208-230/460 87 F L 19-17.2/8.6 21.7-19.6/9.8 168.1-152/76
3 213TC 1.15 575 87 F L 6.9 8.5 61
153 254TC 1.15 208-230/460 86.5 F L 38-34/17 43.6-40/20 376-340/170
3 254TC 1.15 575 86.5 F L 13.6 16 136
203 254TC 1.15 230/460 88.5 F K 46/23 52.4/26.2 420/210
3 284TSC 1.15 575 90.2 F H 19 21.4 138
253 284TSC 1.15 230/460 88.5 F J 58/29 69.4/34.7 496/248
3 284TSC 1.15 575 88.5 F J 23.7 27.8 198.4
303 286TSC 1.15 230/460 91.7 F G 66/33 77.2/38.6 448/224
3 284TSC 1.15 575 91 F G 27.5 31.5 172
403 284TSC 1.15 230/460 90.2 F G 94/47 105.2/52.6 580/290
3 326TSC 1.15 575 F
1All specifications are for TEFC motors. 1-phase (up to 10HP) and ODP motors are available on request. For pumps supplied from Grundfos Canadasee Note 2 on page 5.
max. norm. min. Fluid type:Capacity (gpm) rated max. norm.Discharge Pressure (psig) Fluid Temperature (°F)Hydraulic Power (hp) at designated temperature at designated capacityNPSH Available (ft) Specific Gravity
Model information from Type Key and Codes:Quantity required: Example: CRK 4-120/8 U-W-A-AUUVMinimum required flow: NPSH required at duty point:Product Guide additional information pages
Materials page number: Performance curve page number:Technical data page number:
HP: Phase: Voltage: Enclosure:
Custom-built pump information (optional):
*Pump should be sized to meet the requirements of minimum distance from bottom of tank and minimumfluid level above strainer at all times.