Top Banner
New Green Building Code Chapter 4 Residential Application Thanks to our sponsors:
173

New Green Building Code Chapter 4 Residential Application · New Green Building Code Chapter 4 Residential Application ... § Voluntary measures ... safety and general welfare of

Jun 28, 2018

Download

Documents

truonghanh
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: New Green Building Code Chapter 4 Residential Application · New Green Building Code Chapter 4 Residential Application ... § Voluntary measures ... safety and general welfare of

New Green Building CodeChapter 4

Residential ApplicationThanks to our sponsors:

Page 2: New Green Building Code Chapter 4 Residential Application · New Green Building Code Chapter 4 Residential Application ... § Voluntary measures ... safety and general welfare of

Presenter

Marc Cohen, AIA, LEED AP BD+C/ID+C, LEED FacultyDirector of Sustainable DesignMVE Institutional, [email protected]

Page 3: New Green Building Code Chapter 4 Residential Application · New Green Building Code Chapter 4 Residential Application ... § Voluntary measures ... safety and general welfare of

Today’s Agenda

§ CALGreen – What is it?

§ A review of key sections§ Residential§ Voluntary measures§ Tiers Process

Page 4: New Green Building Code Chapter 4 Residential Application · New Green Building Code Chapter 4 Residential Application ... § Voluntary measures ... safety and general welfare of

California Code of RegulationsTITLE 1. GENERAL PROVISIONSTITLE 2. ADMINISTRATIONTITLE 3. FOOD AND AGRICULTURETITLE 4. BUSINESS REGULATIONSTITLE 5. EDUCATION-------

TITLE 24. BUILDING STANDARDS CODE

Page 5: New Green Building Code Chapter 4 Residential Application · New Green Building Code Chapter 4 Residential Application ... § Voluntary measures ... safety and general welfare of

Title 24: 2010 California Building Standards Code (effective January 1, 2011)

Part 1 – California Administrative CodePart 2 – California Building CodePart 2.5 – California Residential CodePart 3 – California Electrical CodePart 4 – California Mechanical CodePart 5 – California Plumbing CodePart 6 – California Energy CodePart 7 – VacantPart 8 – California Historical Building CodePart 9 – California Fire CodePart 10 – California Existing Building Code

Part 11 – California Green Building Standards CodePart 12 – California Referenced Standards Code

Page 6: New Green Building Code Chapter 4 Residential Application · New Green Building Code Chapter 4 Residential Application ... § Voluntary measures ... safety and general welfare of

California Green Building Standards Code

Overview

Page 7: New Green Building Code Chapter 4 Residential Application · New Green Building Code Chapter 4 Residential Application ... § Voluntary measures ... safety and general welfare of

§ Chapter 1 - Administration

§ Chapter 2 - Definitions

§ Chapter 3 - Green Building

California Green Building Standards Code

Page 8: New Green Building Code Chapter 4 Residential Application · New Green Building Code Chapter 4 Residential Application ... § Voluntary measures ... safety and general welfare of

§ Chapter 4 - Residential Mandatory Measures

§ Chapter 5 - Nonresidential Mandatory Measures

§ Chapter 6 - Reference Organizations and Standards

§ Chapter 7 - Installer and Special Inspector Qualifications

§ Chapter 8 - Compliance Forms and Worksheets

California Green Building Standards Code

Page 9: New Green Building Code Chapter 4 Residential Application · New Green Building Code Chapter 4 Residential Application ... § Voluntary measures ... safety and general welfare of

§ Appendix A4 – Residential § Voluntary measures§ Tiers, Electives & Checklists

California Green Building Standards Code

Page 10: New Green Building Code Chapter 4 Residential Application · New Green Building Code Chapter 4 Residential Application ... § Voluntary measures ... safety and general welfare of

Mandatory < Tier 1 < Tier 2

Tiers – Deeper Shades of Green

Page 11: New Green Building Code Chapter 4 Residential Application · New Green Building Code Chapter 4 Residential Application ... § Voluntary measures ... safety and general welfare of

California Green Building Standards Code

Mandatory Measures

Page 12: New Green Building Code Chapter 4 Residential Application · New Green Building Code Chapter 4 Residential Application ... § Voluntary measures ... safety and general welfare of

Chapter 1 - Administration

Page 13: New Green Building Code Chapter 4 Residential Application · New Green Building Code Chapter 4 Residential Application ... § Voluntary measures ... safety and general welfare of

Chapter 1 - Administration§ (101.1) Title-California Green Building Standards Code

§ CAL Green§ (101.2) Purpose

§ Reduce negative impact§ Encourage sustainable construction

§ (101.3) Scope§ Mandatory only for New Construction§ Buildings covered – state-owned, low-rise residential (up

to 3 stories), nonresidential/commercial, public elementary & secondary schools, community colleges, hospitals,

§ Not intended to be identified as meeting the requirements of a point rated system

Page 14: New Green Building Code Chapter 4 Residential Application · New Green Building Code Chapter 4 Residential Application ... § Voluntary measures ... safety and general welfare of

Chapter 1 - Administration§ (101.4) Appendices (Tiers)

§ Voluntary measures§ Mandatory when adopted by local jurisdiction

§ (101.5) Referenced codes and standards § CBC§ CRC§ CEC§ CMC§ CPC§ CFC§ Energy

Page 15: New Green Building Code Chapter 4 Residential Application · New Green Building Code Chapter 4 Residential Application ... § Voluntary measures ... safety and general welfare of

Chapter 1, continued

§ (101.6) Order of precedence and use.§ Building standard vs. local amendment

§ Local amendment shall govern§ Green code vs. building standards

§ Most restrictive governs§ Specific provision vs. general provision

§ Specific shall govern

Page 16: New Green Building Code Chapter 4 Residential Application · New Green Building Code Chapter 4 Residential Application ... § Voluntary measures ... safety and general welfare of

Chapter 1, continued

§ (101.7) Local amendments based on findings§ Climate – Topography – Geology – Environmental

§ (101.8) Alternate Materials and Methods§ Case by case basis§ Complies with the intent and equivalent

§ (101.9) Effective date – January 1, 2011

Page 17: New Green Building Code Chapter 4 Residential Application · New Green Building Code Chapter 4 Residential Application ... § Voluntary measures ... safety and general welfare of

Chapter 1, continued

§ (101.9) Effective date – January 1, 2011§ (101.11) Effective use of the code

§ Type of occupancy§ Which state agency has authority§ Which chapter applies§ Review adoption tables§ Adopted tiers§ Application checklist

Page 18: New Green Building Code Chapter 4 Residential Application · New Green Building Code Chapter 4 Residential Application ... § Voluntary measures ... safety and general welfare of

Chapter 1, continued

• (102) Construction Documents & Installation Verification• Plan check submittal per city standards• Verification documentation

§ (104) State Agency Authorities§ Department of Community Development (HCD),

residential

Page 19: New Green Building Code Chapter 4 Residential Application · New Green Building Code Chapter 4 Residential Application ... § Voluntary measures ... safety and general welfare of

Chapter 2 – Definitions

§ If used in more than one location in the code a defined term will be located in Chapter 2.

§ If only used in one chapter the defined term will be located in the definition section at the beginning of that chapter.

Page 20: New Green Building Code Chapter 4 Residential Application · New Green Building Code Chapter 4 Residential Application ... § Voluntary measures ... safety and general welfare of

Chapter 2 – Definitions

§ Low Rise Residential Building - a building that is of Occupancy Group “R” and is three stories or less, or that is one- or two-family dwelling or townhouse.

§ Note: check with local jurisdiction for amendment

Page 21: New Green Building Code Chapter 4 Residential Application · New Green Building Code Chapter 4 Residential Application ... § Voluntary measures ... safety and general welfare of

Chapter 3 - Green Building

Page 22: New Green Building Code Chapter 4 Residential Application · New Green Building Code Chapter 4 Residential Application ... § Voluntary measures ... safety and general welfare of

Chapter 3 - Green Building§ Newly constructed buildings

§ Mixed Occupancy Buildings –live/work occupancy

§ Residential occ. comply with Chapter 4

§ Non-residential occ. Comply with Chapter 5

§ Phased Projects

§ Initial tenant/occupancy

§ Voluntary Tiers§ Tier 1 and Tier 2

Page 23: New Green Building Code Chapter 4 Residential Application · New Green Building Code Chapter 4 Residential Application ... § Voluntary measures ... safety and general welfare of

Chapter 3 - Green Building§ Live/work unit

§ Defined in the CBC

§ Permitted to use the CRC

§ Application of CALGreen

§ CALGreen applies to the initial tenant

Page 24: New Green Building Code Chapter 4 Residential Application · New Green Building Code Chapter 4 Residential Application ... § Voluntary measures ... safety and general welfare of

Chapter 4 Residential Mandatory Measures

Page 25: New Green Building Code Chapter 4 Residential Application · New Green Building Code Chapter 4 Residential Application ... § Voluntary measures ... safety and general welfare of

Chapter 4 Matrix Adoption Table

Page 26: New Green Building Code Chapter 4 Residential Application · New Green Building Code Chapter 4 Residential Application ... § Voluntary measures ... safety and general welfare of

• State Housing LawThe SHL was enacted to protect the health, safety and general welfare of the public and occupants of dwelling units in the State of California. Under this authority, HCD promulgates building standards and regulations to ensure that hotels, motel, apartments, single-family dwellings, and other residential buildings are constructed and maintained in compliance with the model building codes and other provisions of State law.

California Department of Housing and Community Development

Page 27: New Green Building Code Chapter 4 Residential Application · New Green Building Code Chapter 4 Residential Application ... § Voluntary measures ... safety and general welfare of

California Department of Housing and Community Development

HCD AuthorityHotels, MotelsApartment HousesDwellingsLodging HousesHomeless SheltersMonasteries, ConventsEmployee HousingFactory-Built Housing

Page 28: New Green Building Code Chapter 4 Residential Application · New Green Building Code Chapter 4 Residential Application ... § Voluntary measures ... safety and general welfare of

Five Divisions

§ Division 4.1 - Planning and Design

§ Division 4.2 - Energy Efficiency

§ Division 4.3 - Water Efficiency and Conservation

§ Division 4.4 - Material Conservation and Resource Efficiency

§ Division 4.5 - Environmental Quality

Chapter 4 - Residential Mandatory Measures

Page 29: New Green Building Code Chapter 4 Residential Application · New Green Building Code Chapter 4 Residential Application ... § Voluntary measures ... safety and general welfare of

Division 4.1 - Planning and Design

Chapter 4

Page 30: New Green Building Code Chapter 4 Residential Application · New Green Building Code Chapter 4 Residential Application ... § Voluntary measures ... safety and general welfare of

§ 4.106.2 – Storm water drainage and retention

§ Identified objectives of storm water management

§ Prevent flooding of adjacent property

§ Prevent storm water pollution runoff from entering storm drain system

§ Retaining soil on-site

§ Prevent runoff from entering streams or rivers.

4.106 – Site Development

Chapter 4

Page 31: New Green Building Code Chapter 4 Residential Application · New Green Building Code Chapter 4 Residential Application ... § Voluntary measures ... safety and general welfare of

§ Less than one acre outside the scope of the California State Water Resources Control Board (SWRCB).

§ Establishes criteria for a plan to manage storm water drainage during construction.

§ Create an effective combination of erosion and sediment controls

§ BMP’s continually evolve as onsite activities change

4.106.2 - Storm water drainage and retentionduring construction

Chapter 4

Page 32: New Green Building Code Chapter 4 Residential Application · New Green Building Code Chapter 4 Residential Application ... § Voluntary measures ... safety and general welfare of

How to comply§ Retention basin sized and

shown on the site plan.

§ Filtering storm water and routing to a public drainage system.

§ Compliance with local storm water ordinance.

§ Develop & implement additional BMP’s

4.106.2 - Storm water drainage and retention

Chapter 4

Page 33: New Green Building Code Chapter 4 Residential Application · New Green Building Code Chapter 4 Residential Application ... § Voluntary measures ... safety and general welfare of

4.106.2 - Storm water drainage and retention

Chapter 4

Page 34: New Green Building Code Chapter 4 Residential Application · New Green Building Code Chapter 4 Residential Application ... § Voluntary measures ... safety and general welfare of

Types of BMP’s methods § Silt fencing

§ Hay bales/mulch

§ Erosion control matting

§ Inlet protectors

§ Sand/gravel bags

§ Fiber rolls/wattles

4.106.2 - Storm water drainage and retention

Chapter 4

Page 35: New Green Building Code Chapter 4 Residential Application · New Green Building Code Chapter 4 Residential Application ... § Voluntary measures ... safety and general welfare of

Questions

Page 36: New Green Building Code Chapter 4 Residential Application · New Green Building Code Chapter 4 Residential Application ... § Voluntary measures ... safety and general welfare of

§ Prevent surface from entering the building

§ Requires planning of the surface drainage system that will serve the site.

§ Requires the construction plans to indicate how surface drainage will be managed.

4.106.3 Surface Drainage

Chapter 4

Page 37: New Green Building Code Chapter 4 Residential Application · New Green Building Code Chapter 4 Residential Application ... § Voluntary measures ... safety and general welfare of

How to comply§ Drainage system is shown on site plan.

§ Swales

§ Drain piping

§ Retention areas

§ Ground water recharge

4.106.3 Surface Drainage

Chapter 4

Page 38: New Green Building Code Chapter 4 Residential Application · New Green Building Code Chapter 4 Residential Application ... § Voluntary measures ... safety and general welfare of

Design strategies§ Roof overhangs

§ Sloped ground

§ Properly placed drains

§ Above & below ground drain systems

4.106.3 Surface Drainage

Chapter 4

Page 39: New Green Building Code Chapter 4 Residential Application · New Green Building Code Chapter 4 Residential Application ... § Voluntary measures ... safety and general welfare of

Water Containment Measures

Page 40: New Green Building Code Chapter 4 Residential Application · New Green Building Code Chapter 4 Residential Application ... § Voluntary measures ... safety and general welfare of

Site drainage plans§ Rainwater penetrating area

§ Above ground

§ Below ground

§ Natural environment

4.106.3 Surface Drainage

Chapter 4

Page 41: New Green Building Code Chapter 4 Residential Application · New Green Building Code Chapter 4 Residential Application ... § Voluntary measures ... safety and general welfare of

Questions

Page 42: New Green Building Code Chapter 4 Residential Application · New Green Building Code Chapter 4 Residential Application ... § Voluntary measures ... safety and general welfare of

Division 4.2 - Energy Efficiency

Chapter 4

Page 43: New Green Building Code Chapter 4 Residential Application · New Green Building Code Chapter 4 Residential Application ... § Voluntary measures ... safety and general welfare of

4.201.1 - Minimum Energy Performance for Low-Rise Residential Buildings.

§ The California Energy Commission (CEC) adopts regulations to establish the minimum level of energy efficiency that a heated or cooled structure must meet or exceed.

Chapter 4

Page 44: New Green Building Code Chapter 4 Residential Application · New Green Building Code Chapter 4 Residential Application ... § Voluntary measures ... safety and general welfare of

California Energy Code

Chapter 4

Effective January 1, 2010www.energy.ca.gov/title24

Page 45: New Green Building Code Chapter 4 Residential Application · New Green Building Code Chapter 4 Residential Application ... § Voluntary measures ... safety and general welfare of

4.201.1 - Energy Efficiency

How to comply§ Prescriptive Method

§ Performance Method

§ Tiers

§ Performance calculation can show percentages above minimum

Chapter 4

Page 46: New Green Building Code Chapter 4 Residential Application · New Green Building Code Chapter 4 Residential Application ... § Voluntary measures ... safety and general welfare of

4.201.1 - Energy Efficiency

Chapter 4

CEC Table 100A•Mandatory•Prescriptive•Performance

Performance•Micropas 8.1•Energypro 5.1

Page 47: New Green Building Code Chapter 4 Residential Application · New Green Building Code Chapter 4 Residential Application ... § Voluntary measures ... safety and general welfare of

Questions

Page 48: New Green Building Code Chapter 4 Residential Application · New Green Building Code Chapter 4 Residential Application ... § Voluntary measures ... safety and general welfare of

Division 4.3 Water Efficiency and Conservation

Chapter 4

Page 49: New Green Building Code Chapter 4 Residential Application · New Green Building Code Chapter 4 Residential Application ... § Voluntary measures ... safety and general welfare of

4.303.1 - 20% Water savings

§ Requires a 20% reduction of indoor water use

§ Mandatory effective date is July 1, 2011

§ Manufacture fixture availability

§ Provides a prescriptive and performance method

§ Water closets, urinals, faucets and showerheads

§ Submitted at plan check

Chapter 4

Page 50: New Green Building Code Chapter 4 Residential Application · New Green Building Code Chapter 4 Residential Application ... § Voluntary measures ... safety and general welfare of

4.303.1 - 20% Indoor water savings

Toilets

• Standard 1.6 gals

• 20% reduction 1.28 gals

• Types

• Single flush

• Dual flush

• 2 flushes= 1.0 gal/flush

• 1 flush = 1.6 gal/flush

Chapter 4

Page 51: New Green Building Code Chapter 4 Residential Application · New Green Building Code Chapter 4 Residential Application ... § Voluntary measures ... safety and general welfare of

4.303.1 - 20% Indoor water savings

Urinals

• Standard 1.0 gals

• 20% reduction .5 gals (50%)

• New standards

• 0.125 gal/flush

• 0.0 flow

Chapter 4

Page 52: New Green Building Code Chapter 4 Residential Application · New Green Building Code Chapter 4 Residential Application ... § Voluntary measures ... safety and general welfare of

4.303.1 - 20% Indoor water savings

Showerhead

• Standard 2.5 gpm @ 80psi

• 20% reduction 2.0 gpm @ 80psi

• 0.5 gpm to 1.6 gpm showerheads are available

• Flow rates higher than 2.0 gpm require performance method

Chapter 4

Page 53: New Green Building Code Chapter 4 Residential Application · New Green Building Code Chapter 4 Residential Application ... § Voluntary measures ... safety and general welfare of

4.303.1 - 20% Indoor water savings

Lavatory Faucets

• Standard 2.2 gpm @ 60psi

• 20% reduction 1.5 gpm @ 60psi

• May not be less than 0.8 gpm @ 20psi

• If faucet has higher flow rate, performance method

Chapter 4

Page 54: New Green Building Code Chapter 4 Residential Application · New Green Building Code Chapter 4 Residential Application ... § Voluntary measures ... safety and general welfare of

4.303.1 - 20% Indoor water savings/Prescriptive

Chapter 4

Kitchen faucets called out in Tiers

Page 55: New Green Building Code Chapter 4 Residential Application · New Green Building Code Chapter 4 Residential Application ... § Voluntary measures ... safety and general welfare of

4.303.1 - 20% Indoor water savings

How to comply method #1Prescriptive Method

§ Table 4.303.2

§ Showerheads ≤ 2.0 gpm @ 80 psi

§ Lavatory Faucets ≤ 1.5 gpm @ 60 psi

§ Min. flow 0.8 gpm @ 20psi

§ Kitchen Faucets ≤ 1.8 gpm @ 60 psi

§ Urinals ≤ .5 gal/flush

§ Water closets ≤ 1.28 gallon effective flush rate

Chapter 4

Page 56: New Green Building Code Chapter 4 Residential Application · New Green Building Code Chapter 4 Residential Application ... § Voluntary measures ... safety and general welfare of

4.303.1 - 20% Indoor water savingsCompliance and verification§ Plan check submittal doc§ Field verification§ City inspection§ Third party§Self certification

Chapter 4

Page 57: New Green Building Code Chapter 4 Residential Application · New Green Building Code Chapter 4 Residential Application ... § Voluntary measures ... safety and general welfare of

4.303.1 20% - Indoor water savingsHow to comply method #2Performance Method

§ Use the performance calculation worksheets in Chapter 8 or other calculation acceptable to the enforcing agency.

§ Fixtures used in performance calculation are limited.

§ Water closets

§ Urinals

§ Lavatory Faucets

§ Showerheads

Chapter 4

Page 58: New Green Building Code Chapter 4 Residential Application · New Green Building Code Chapter 4 Residential Application ... § Voluntary measures ... safety and general welfare of

4.303.1 - 20% Indoor water savings

Chapter 4

Performance methodCalculate baseline water use§WS -1§Comply with footnotes for table 4.303.1

Page 59: New Green Building Code Chapter 4 Residential Application · New Green Building Code Chapter 4 Residential Application ... § Voluntary measures ... safety and general welfare of

4.303.1 20% - Indoor water savings/performance

Develop baseline water use

Chapter 4

Example: declaration of no urinals

Page 60: New Green Building Code Chapter 4 Residential Application · New Green Building Code Chapter 4 Residential Application ... § Voluntary measures ... safety and general welfare of

4.303.1 - 20% Indoor water savings

Chapter 4

Page 61: New Green Building Code Chapter 4 Residential Application · New Green Building Code Chapter 4 Residential Application ... § Voluntary measures ... safety and general welfare of

4.303.1 20% - Indoor water savings/performance

Develop baseline water use

Chapter 4

Page 62: New Green Building Code Chapter 4 Residential Application · New Green Building Code Chapter 4 Residential Application ... § Voluntary measures ... safety and general welfare of

4.303.1 - 20% Indoor water savings

Chapter 4

Page 63: New Green Building Code Chapter 4 Residential Application · New Green Building Code Chapter 4 Residential Application ... § Voluntary measures ... safety and general welfare of

4.303.1 - 20% Indoor water savingsCompliance and verification

Chapter 4

Page 64: New Green Building Code Chapter 4 Residential Application · New Green Building Code Chapter 4 Residential Application ... § Voluntary measures ... safety and general welfare of

4.303.1 - 20% Indoor water savingsCompliance and self certification

Chapter 4

Page 65: New Green Building Code Chapter 4 Residential Application · New Green Building Code Chapter 4 Residential Application ... § Voluntary measures ... safety and general welfare of

4.303.2 - Multiple Showerheads Serving One Shower

§When using the prescriptive method, the sum of multiple showerheads shall not exceed the flow rate specified in Table 4.303.2.

§When using the performance method, the maximum flow rate for each shower head shall not exceed 2.5 gpm @ 80 psi.

Chapter 4

Page 66: New Green Building Code Chapter 4 Residential Application · New Green Building Code Chapter 4 Residential Application ... § Voluntary measures ... safety and general welfare of

4.303.2 - Multiple Showerheads Serving One Shower

§When single shower fixtures are served by more than one showerhead, the combined flow rate of all showerheads shall not exceed the maximum flow rates specified in the 20% reduction column contained in Table 4.303.2

§The shower shall be designed to only allow one showerhead to be in operation at a time

Chapter 4

Page 67: New Green Building Code Chapter 4 Residential Application · New Green Building Code Chapter 4 Residential Application ... § Voluntary measures ... safety and general welfare of

4.303.1 - 20% Indoor water savingsCompliance and verification§ Plan check submittal doc§ Field verification§ City inspection§ Third party§Self certification

Chapter 4

Page 68: New Green Building Code Chapter 4 Residential Application · New Green Building Code Chapter 4 Residential Application ... § Voluntary measures ... safety and general welfare of

4.303.1 - 20% Indoor water savingsCompliance and self certification

Chapter 4

Page 69: New Green Building Code Chapter 4 Residential Application · New Green Building Code Chapter 4 Residential Application ... § Voluntary measures ... safety and general welfare of

4.303.3 Plumbing Fixtures and Fittings

§Specifies acceptable performance standards for plumbing fixtures with reduced water usage.

Chapter 4

Page 70: New Green Building Code Chapter 4 Residential Application · New Green Building Code Chapter 4 Residential Application ... § Voluntary measures ... safety and general welfare of

4.303.3 - Plumbing Fixtures and Fittings

How to comply§Install a fixture that meets the standards listed in Table 4.303.3.

§Obtain alternate approval from the enforcing agency for use of fixtures not listed.

Chapter 4

Page 71: New Green Building Code Chapter 4 Residential Application · New Green Building Code Chapter 4 Residential Application ... § Voluntary measures ... safety and general welfare of

Questions

Page 72: New Green Building Code Chapter 4 Residential Application · New Green Building Code Chapter 4 Residential Application ... § Voluntary measures ... safety and general welfare of

4.304.1 - Irrigation Controllers

§Requires smart irrigation controls to be weather- or soil moisture-based and automatically adjust irrigation in response to changes in plants' needs as weather conditions change, or have rain sensors or communication systems that account for local rainfall.

Chapter 4

Page 73: New Green Building Code Chapter 4 Residential Application · New Green Building Code Chapter 4 Residential Application ... § Voluntary measures ... safety and general welfare of

4.304.1 - Irrigation Controllers

Compliance conditions§ When provided by builder, installed at final

§Smart irrigation control system

§Automatically delay watering

§Types are communication-based, soil moisture or plan watering needs

Chapter 4

Page 74: New Green Building Code Chapter 4 Residential Application · New Green Building Code Chapter 4 Residential Application ... § Voluntary measures ... safety and general welfare of

4.304.1 - Irrigation Controllers

How to comply§Established during the design phase

§Evaluate land topography

§Soil type

§Water availability and pressure

§Plan type

§Climate conditions

Chapter 4

Page 75: New Green Building Code Chapter 4 Residential Application · New Green Building Code Chapter 4 Residential Application ... § Voluntary measures ... safety and general welfare of

4.304.1 - Irrigation Controllers

Model Landscape Ordinance (MLO)§Calif. Department of Water Resources

§Effective date January 1, 2010

§Mandate cities to adopt local MLO ordinance

§Promote efficient water use

§Promote the values of efficient landscape design

§Local ord. can be more restrictive than state

Chapter 4

Page 76: New Green Building Code Chapter 4 Residential Application · New Green Building Code Chapter 4 Residential Application ... § Voluntary measures ... safety and general welfare of

State MLO

Chapter 4

Page 77: New Green Building Code Chapter 4 Residential Application · New Green Building Code Chapter 4 Residential Application ... § Voluntary measures ... safety and general welfare of

State MLO

Chapter 4

Page 78: New Green Building Code Chapter 4 Residential Application · New Green Building Code Chapter 4 Residential Application ... § Voluntary measures ... safety and general welfare of

State MLO

Chapter 4

Page 79: New Green Building Code Chapter 4 Residential Application · New Green Building Code Chapter 4 Residential Application ... § Voluntary measures ... safety and general welfare of

Questions

Page 80: New Green Building Code Chapter 4 Residential Application · New Green Building Code Chapter 4 Residential Application ... § Voluntary measures ... safety and general welfare of

Division 4.4Material Conservation and Resource Efficiency

Chapter 4

Page 81: New Green Building Code Chapter 4 Residential Application · New Green Building Code Chapter 4 Residential Application ... § Voluntary measures ... safety and general welfare of

4.406.1 - Joints and Openings

§Condition from un-condition area§Annular spaces

§Gas, plumbing§Electrical§Other necessary penetrations

§Comply with CEC requirements§Exceptions

Chapter 4

Page 82: New Green Building Code Chapter 4 Residential Application · New Green Building Code Chapter 4 Residential Application ... § Voluntary measures ... safety and general welfare of

4.406.1 - Joints and Openings

How to comply§Use metal plates or covers.

§Use cementitious material to seal opening.

§Other methods approved by the enforcing agency.

Chapter 4

Page 83: New Green Building Code Chapter 4 Residential Application · New Green Building Code Chapter 4 Residential Application ... § Voluntary measures ... safety and general welfare of

4.408.1 through 4.408.2.2 - Construction Waste Reduction, Disposal and Recycling

§Requires at least of 50% of nonhazardous construction and demolition debris to be recycled and/or salvaged for reuse

§Compliance with a local waste ordinance which is more stringent.

§Exceptions:§Soil and land clearing debris are exempt.

§Alternate methods or exceptions may be approved due to local constraints.

Chapter 4

Page 84: New Green Building Code Chapter 4 Residential Application · New Green Building Code Chapter 4 Residential Application ... § Voluntary measures ... safety and general welfare of

4.408.1 Construction waste reduction

Purpose/methods§Divert materials from the landfill

§Calculating methods

§Weight

§Volume

§Not both

Chapter 4

Page 85: New Green Building Code Chapter 4 Residential Application · New Green Building Code Chapter 4 Residential Application ... § Voluntary measures ... safety and general welfare of

4.408.1 through 4.408.2.2

How to comply§Comply with local waste management ordinance

OR

§Develop a waste management plan and submit for approval to the enforcing agency.

§Provide documentation of compliance.§HCD is developing additional forms.

§Sample forms are provided in Chapter 8.

Chapter 4

Page 86: New Green Building Code Chapter 4 Residential Application · New Green Building Code Chapter 4 Residential Application ... § Voluntary measures ... safety and general welfare of

4.408.1 through 4.408.2.2

Chapter 4

Page 87: New Green Building Code Chapter 4 Residential Application · New Green Building Code Chapter 4 Residential Application ... § Voluntary measures ... safety and general welfare of

4.408.1 Construction waste reduction

Considerations§Local authority approved hauler

§Location site of recycler

§Method of recycling, onsite sorting or commingling

§Recycler has a good track record

§Subcontractors are on board for compliance

§Tags are collected and recorded

§Self hauling, when authorized

Chapter 4

Page 88: New Green Building Code Chapter 4 Residential Application · New Green Building Code Chapter 4 Residential Application ... § Voluntary measures ... safety and general welfare of

4.408.1 Construction waste reduction

Chapter 4

Weights and volumes examples in guide

Page 89: New Green Building Code Chapter 4 Residential Application · New Green Building Code Chapter 4 Residential Application ... § Voluntary measures ... safety and general welfare of

4.408.1 Construction waste reduction

Chapter 4

Page 90: New Green Building Code Chapter 4 Residential Application · New Green Building Code Chapter 4 Residential Application ... § Voluntary measures ... safety and general welfare of

4.408.2 Construction waste management plan

Local jurisdiction without ordinance§Approved hauler or self hauler

§Provide locations for recycler

§Develop sorting methods, onsite or offsite

§Demo contractor has good record of compliance

§Compliance by all trades

§Maintain accurate records

§Reused materials approved by the Building Official

Chapter 4

Page 91: New Green Building Code Chapter 4 Residential Application · New Green Building Code Chapter 4 Residential Application ... § Voluntary measures ... safety and general welfare of

4.408.1 through 4.408.2.2

Chapter 4

Page 92: New Green Building Code Chapter 4 Residential Application · New Green Building Code Chapter 4 Residential Application ... § Voluntary measures ... safety and general welfare of

4.408.1 through 4.408.2.2

Chapter 4

What is Green Halo?• Online waste management system

• Waste diversion reporting and tracking.

• Accurate information and data

• Streamlines the entire waste diversion process.

• Interactive software between contractors, recyclers, state and local government agencies.

www.greenhalosystems.com

Page 93: New Green Building Code Chapter 4 Residential Application · New Green Building Code Chapter 4 Residential Application ... § Voluntary measures ... safety and general welfare of

4.410.1 - Building Maintenance and Operation

Operation & Maintenance Manual

§Requires educational materials, operation and maintenance manuals are provided to ensure buildings and equipment are properly maintained.

§Other information such as landscape design and maintenance, public transportation options, recycle opportunities, special inspection reports, and energy incentive programs.

Chapter 4

Page 94: New Green Building Code Chapter 4 Residential Application · New Green Building Code Chapter 4 Residential Application ... § Voluntary measures ... safety and general welfare of

4.410.1 - Building Maintenance and Operation

Chapter 4

Manual contents:•Manual to remain with the building for the cycle of the structure•Operation and maintenance instructions:

•Equipment and appliances•Roof and yard drainage•Space conditioning system•Landscape and irrigation plans•Water reuse system•Warranties•Sub-contractors name and phone numbers

Page 95: New Green Building Code Chapter 4 Residential Application · New Green Building Code Chapter 4 Residential Application ... § Voluntary measures ... safety and general welfare of

4.410.1 - Building Maintenance and Operation

Chapter 4

Manual contents:•Local utility and recycling programs•Public transportation•Advantages of maintaining 30% to 60% humidity•Information about water conserving landscape•Maintaining gutters and downspouts •Diverting water at least 5 feet away•Maintenance for caulking, painting, and etc•Info about solar energy & incentive programs•Copy of special inspections & verifications

Page 96: New Green Building Code Chapter 4 Residential Application · New Green Building Code Chapter 4 Residential Application ... § Voluntary measures ... safety and general welfare of

4.410.1 - Building Maintenance and Operation

How to comply§Develop a manual and place it in the home at the time of final inspection.

§“Manual shall remain with the building for the life cycle of the structure

§Media shall be approved by the enforcing agency.

§Paper, electronic, or web base

§HCD is developing a sample standard format for the manual.

Chapter 4

Page 97: New Green Building Code Chapter 4 Residential Application · New Green Building Code Chapter 4 Residential Application ... § Voluntary measures ... safety and general welfare of

4.410.1 - Building Maintenance and Operation

Chapter 4

State provided format:

http://www.hcd.ca.gov/CALGreen.html

Page 98: New Green Building Code Chapter 4 Residential Application · New Green Building Code Chapter 4 Residential Application ... § Voluntary measures ... safety and general welfare of

Questions

Page 99: New Green Building Code Chapter 4 Residential Application · New Green Building Code Chapter 4 Residential Application ... § Voluntary measures ... safety and general welfare of

Division 4.5 – Environmental Quality

Chapter 4

Page 100: New Green Building Code Chapter 4 Residential Application · New Green Building Code Chapter 4 Residential Application ... § Voluntary measures ... safety and general welfare of

4.503.1 - Fireplaces

Requires gas fireplaces to be direct-vent, wood and pellet stoves to comply with EPA limits or comply with a local ordinance, whichever is more prohibitive.

Chapter 4

Page 101: New Green Building Code Chapter 4 Residential Application · New Green Building Code Chapter 4 Residential Application ... § Voluntary measures ... safety and general welfare of

4.503.1 - Fireplaces

How to comply§Install direct vent gas fireplaces.

§Install a pellet or wood stove which meets US EPA Phase II emission standards.

§Comply with local ordinance.

Chapter 4

Page 102: New Green Building Code Chapter 4 Residential Application · New Green Building Code Chapter 4 Residential Application ... § Voluntary measures ... safety and general welfare of

4.503.1 - Fireplaces

Direct vent fireplace§Pull outside air to assist in combustion

§Vent byproducts to the outside

§Seal fireplace prevents contaminates infiltrating the indoor air

Chapter 4

Page 103: New Green Building Code Chapter 4 Residential Application · New Green Building Code Chapter 4 Residential Application ... § Voluntary measures ... safety and general welfare of

4.503.1 - Fireplaces

Chapter 4

Page 104: New Green Building Code Chapter 4 Residential Application · New Green Building Code Chapter 4 Residential Application ... § Voluntary measures ... safety and general welfare of

Questions

Page 105: New Green Building Code Chapter 4 Residential Application · New Green Building Code Chapter 4 Residential Application ... § Voluntary measures ... safety and general welfare of

4.504.1 - Covering of Duct Openings and Protection of Mechanical Equipment During Construction

Requires duct openings, permanent mechanical equipment and other components that will be used to move air in the building after occupancy to be protected from contamination during construction.

Chapter 4

Page 106: New Green Building Code Chapter 4 Residential Application · New Green Building Code Chapter 4 Residential Application ... § Voluntary measures ... safety and general welfare of

4.504.1 - Covering of Duct Openings and Protection of Mechanical Equipment During Construction

Chapter 4

Purpose is to remove:•Construction dust•Debris•Airborne contaminates

Page 107: New Green Building Code Chapter 4 Residential Application · New Green Building Code Chapter 4 Residential Application ... § Voluntary measures ... safety and general welfare of

4.504.1 - Covering of Duct Openings and Protection of Mechanical Equipment During Construction

Chapter 4

Where and when:•During the entire construction process•Protected and wrapped when stored on site•MERV 6 or 8 filter to be installed if system is operated during construction•If operated during construction:

•Entire system cleaned •Entire system inspected

Page 108: New Green Building Code Chapter 4 Residential Application · New Green Building Code Chapter 4 Residential Application ... § Voluntary measures ... safety and general welfare of

4.504.1 - Covering of Duct Openings and Protection of Mechanical Equipment During Construction

How to comply§Cover return and supply openings with plastic or sheet metal.

§Wrap or protect equipment stored on the jobsite for future installation.

§If necessary, plan for alternate space conditioning systems during construction.

Chapter 4

Page 109: New Green Building Code Chapter 4 Residential Application · New Green Building Code Chapter 4 Residential Application ... § Voluntary measures ... safety and general welfare of

Questions

Page 110: New Green Building Code Chapter 4 Residential Application · New Green Building Code Chapter 4 Residential Application ... § Voluntary measures ... safety and general welfare of

4.504.2 - Finish Material Pollutant Control

Limits pollutants from the off-gassing of finish materials inside a residence.

Tables are provided that establish limits on the emissions of VOCs in adhesives, paints, and other coatings.

VOC limitations are also included for carpet, carpet cushions and carpet pad adhesives.

Chapter 4

Page 111: New Green Building Code Chapter 4 Residential Application · New Green Building Code Chapter 4 Residential Application ... § Voluntary measures ... safety and general welfare of

4.504.2 - Finish Material Pollutant Control

Chapter 4

South Coast Air Quality Management District (SCAQMD)•Established limits•Improve indoor air quality•Improve occupant health and comfort•Compliance with SCAQMD Rule 1168

Page 112: New Green Building Code Chapter 4 Residential Application · New Green Building Code Chapter 4 Residential Application ... § Voluntary measures ... safety and general welfare of

4.504.2 - Finish Material Pollutant Control

Chapter 4

4.504.2.1 Adhesives, sealants, and caulks•Adhesives•Adhesives bond primers•Adhesive primers•Sealants•Sealant primers

Page 113: New Green Building Code Chapter 4 Residential Application · New Green Building Code Chapter 4 Residential Application ... § Voluntary measures ... safety and general welfare of

4.504.2 - Finish Material Pollutant Control

Chapter 4

Page 114: New Green Building Code Chapter 4 Residential Application · New Green Building Code Chapter 4 Residential Application ... § Voluntary measures ... safety and general welfare of

4.504.2 - Finish Material Pollutant Control

Chapter 4

Page 115: New Green Building Code Chapter 4 Residential Application · New Green Building Code Chapter 4 Residential Application ... § Voluntary measures ... safety and general welfare of

4.504.2 - Finish Material Pollutant Control

Chapter 4

Page 116: New Green Building Code Chapter 4 Residential Application · New Green Building Code Chapter 4 Residential Application ... § Voluntary measures ... safety and general welfare of

4.504.2 - Finish Material Pollutant Control

Chapter 4

Page 117: New Green Building Code Chapter 4 Residential Application · New Green Building Code Chapter 4 Residential Application ... § Voluntary measures ... safety and general welfare of

4.504.2 - Finish Material Pollutant Control

Chapter 4

Page 118: New Green Building Code Chapter 4 Residential Application · New Green Building Code Chapter 4 Residential Application ... § Voluntary measures ... safety and general welfare of

4.504.2 - Finish Material Pollutant Control

Chapter 4

Page 119: New Green Building Code Chapter 4 Residential Application · New Green Building Code Chapter 4 Residential Application ... § Voluntary measures ... safety and general welfare of

4.504.2 - Finish Material Pollutant Control

§A table addressing the formaldehyde limits was developed based on maximum allowable limits recently established by the California Air Resources Board (ARB).

§Ensures these levels are met by including a mandatory verification component which requires certification or documentation.

Chapter 4

Page 120: New Green Building Code Chapter 4 Residential Application · New Green Building Code Chapter 4 Residential Application ... § Voluntary measures ... safety and general welfare of

4.504.2 - Finish Material Pollutant Control

Chapter 4

Page 121: New Green Building Code Chapter 4 Residential Application · New Green Building Code Chapter 4 Residential Application ... § Voluntary measures ... safety and general welfare of

4.504.2 - Finish Material Pollutant Control

Chapter 4

Page 122: New Green Building Code Chapter 4 Residential Application · New Green Building Code Chapter 4 Residential Application ... § Voluntary measures ... safety and general welfare of

4.504.2 - Finish Material Pollutant Control

Chapter 4

4.504.2.1 Adhesives, sealants, and caulks•Methods of compliance

•Tech data sheets•MSDS•MFG compliance letter•Custody letter from distributer

Page 123: New Green Building Code Chapter 4 Residential Application · New Green Building Code Chapter 4 Residential Application ... § Voluntary measures ... safety and general welfare of

4.504.2 - Finish Material Pollutant Control

How to comply§Collect material specification sheets and make them available at time of inspection.

§Product labels.

§Use the specification sheet HCD is developing as a compliance aid for this section.

Chapter 4

Page 124: New Green Building Code Chapter 4 Residential Application · New Green Building Code Chapter 4 Residential Application ... § Voluntary measures ... safety and general welfare of

4.504.3 - Finish Material Pollutant Control

Carpet system§Carpet, carpet pad, and glue

§Carpet system shall comply with the code

Chapter 4

Page 125: New Green Building Code Chapter 4 Residential Application · New Green Building Code Chapter 4 Residential Application ... § Voluntary measures ... safety and general welfare of

4.504.3 - Finish Material Pollutant Control

How to comply§Carpet and Rug Institute Green Label Plus Program

§California Department of Public Health Standard Practice for the testing of VOC’s (Spec. 01350)

§NSF/ANSI 140 at the Gold Level

§Scientific Certification System Indoor Advantage Gold

Chapter 4

Page 126: New Green Building Code Chapter 4 Residential Application · New Green Building Code Chapter 4 Residential Application ... § Voluntary measures ... safety and general welfare of

4.504.3 - Finish Material Pollutant Control

Verification and compliance§Contractor should be cognizant of code requirements

§Third party verification

§Mfg documents

§Local polices and procedures

Chapter 4

Page 127: New Green Building Code Chapter 4 Residential Application · New Green Building Code Chapter 4 Residential Application ... § Voluntary measures ... safety and general welfare of

Questions

Page 128: New Green Building Code Chapter 4 Residential Application · New Green Building Code Chapter 4 Residential Application ... § Voluntary measures ... safety and general welfare of

4.505.2 - Concrete Slab Foundations

§Capillary Break

§Provides explicit requirements for the installation of vapor barriers in slab on grade foundations to address moisture and mold issues that can negatively affect indoor air quality as well as damage floor coverings.

§Allows equivalent methods to be used provided the same protections will be maintained.

Chapter 4

Page 129: New Green Building Code Chapter 4 Residential Application · New Green Building Code Chapter 4 Residential Application ... § Voluntary measures ... safety and general welfare of

4.505.2 – Concrete Slab Foundations

How to comply§Follow the prescriptive requirements in this section.

§Obtain approval from the enforcing agency for an alternate design.

§Use the design specified by a licensed California architect or engineer.

§Specifies an aggregate base of ½” or larger material must be used as a capillary break and clarifies that the vapor retarder must be placed above the aggregate and in direct contact with the concrete slab.

Chapter 4

Page 130: New Green Building Code Chapter 4 Residential Application · New Green Building Code Chapter 4 Residential Application ... § Voluntary measures ... safety and general welfare of

4.505.2 – Concrete Slab Foundations

Chapter 4

Page 131: New Green Building Code Chapter 4 Residential Application · New Green Building Code Chapter 4 Residential Application ... § Voluntary measures ... safety and general welfare of

4.505.2 – Concrete Slab Foundations

Vapor retarder consideration§Low moisture vapor transmission

§High tensile strength

§High puncture resistance

§Resistant to chemical or environmental attacks

§Over lapped 6 inches

§Use moisture resistant tape

Chapter 4

Page 132: New Green Building Code Chapter 4 Residential Application · New Green Building Code Chapter 4 Residential Application ... § Voluntary measures ... safety and general welfare of

4.505.2 – Concrete Slab Foundations

Chapter 4

Page 133: New Green Building Code Chapter 4 Residential Application · New Green Building Code Chapter 4 Residential Application ... § Voluntary measures ... safety and general welfare of

4.505.2 – Concrete Slab Foundations

Chapter 4

ACI 302.2R-06 recommendations

•Proposed installation be independently evaluated as to the moisture sensitivity of the floor finishes

•Anticipate project conditions

•Potential effects of slab curling, crusting, and cracking

•Benefits and risk associated with the location of the vapor retarder by Geo., EOR, and others

Page 134: New Green Building Code Chapter 4 Residential Application · New Green Building Code Chapter 4 Residential Application ... § Voluntary measures ... safety and general welfare of

Questions

Page 135: New Green Building Code Chapter 4 Residential Application · New Green Building Code Chapter 4 Residential Application ... § Voluntary measures ... safety and general welfare of

4.505.3 - Moisture Content of Building Materials

§Requires the moisture content of construction materials and insulation to be verified prior to approval to enclose wall and floor cavities with drywall or other finish surfaces.

§HCD currently adopts sections of the CBC which specify maximum grading and mill certification levels of moisture in framing materials.

§This section requires field verification and protection during wet weather.

Chapter 4

Page 136: New Green Building Code Chapter 4 Residential Application · New Green Building Code Chapter 4 Residential Application ... § Voluntary measures ... safety and general welfare of

4.505.3 – Moisture Content of Building Materials

How to comply§Cover building materials to protect them from rain.

§Ensure the building is weather tight before insulating.

§Use other precautions necessary to ensure the building materials are kept dry.

§Test for moisture levels.

Chapter 4

Page 137: New Green Building Code Chapter 4 Residential Application · New Green Building Code Chapter 4 Residential Application ... § Voluntary measures ... safety and general welfare of

4.506.1 - Bathroom Exhaust Fans

§Requires exhaust fans in any room that contains a bathtub or shower.§Allows a whole house ventilation system designed to provide outside air to be used to comply with this section.§Intended to reduce moisture inside the residence.§Fans must be ENERGY STAR compliant.§Humidistat controls: 50% to 80%

Chapter 4

Page 138: New Green Building Code Chapter 4 Residential Application · New Green Building Code Chapter 4 Residential Application ... § Voluntary measures ... safety and general welfare of

4.506.1 - Bathroom Exhaust Fans

How to comply§If not part of a whole house ventilation system.

§Install ENERGY STAR fans with humidistat controls in each bathroom.

§A bathroom is a room that contains a bathtub or a shower or a combination of the two.

Chapter 4

Page 139: New Green Building Code Chapter 4 Residential Application · New Green Building Code Chapter 4 Residential Application ... § Voluntary measures ... safety and general welfare of

4.507.1 - Openings

§Requires the openings for whole house exhaust fans to be insulated.

Chapter 4

Minimum insulationfor louvers R 4.2

Page 140: New Green Building Code Chapter 4 Residential Application · New Green Building Code Chapter 4 Residential Application ... § Voluntary measures ... safety and general welfare of

4.507.1 - Openings

How to comply§Install a whole house fan with insulated louvers.

§Install a fan with an insulated cover.

§Use a fan with insulated duct connected to penetrations in the conditioned envelope.

Chapter 4

Page 141: New Green Building Code Chapter 4 Residential Application · New Green Building Code Chapter 4 Residential Application ... § Voluntary measures ... safety and general welfare of

Questions

Page 142: New Green Building Code Chapter 4 Residential Application · New Green Building Code Chapter 4 Residential Application ... § Voluntary measures ... safety and general welfare of

4.507.2 - Heating and Air-conditioning System

§Establishes minimum requirements for heating and air conditioning design.

§Heat loss and heat gain.§Duct system sizing.§Equipment selection.

§Allows designers flexibility to design based on local conditions.

Chapter 4

Page 143: New Green Building Code Chapter 4 Residential Application · New Green Building Code Chapter 4 Residential Application ... § Voluntary measures ... safety and general welfare of

4.507.2 - Heating and Air-conditioning System

How to comply§Heat loss and heat gain calculation using software or hand calculations or an equivalent.

§Duct system design to ensure adequate air flow is provided to address the heat loss and gain in each area of the home.

§Select equipment which will provide the necessary air flow and level of conditioning to satisfy the loads, function within the duct design criteria and within the equipment limitations.

Chapter 4

Page 144: New Green Building Code Chapter 4 Residential Application · New Green Building Code Chapter 4 Residential Application ... § Voluntary measures ... safety and general welfare of

4.507.2 - Heating and Air-conditioning System

How to comply§Heat loss & gain per ACCA Manual J or ASHRAE handbooks

§Duct sizing per ACCA 29-D Manual D or ASHRAE handbooks

§Select equipment ACCA 36-S Manual S or equivalent

Chapter 4

Page 145: New Green Building Code Chapter 4 Residential Application · New Green Building Code Chapter 4 Residential Application ... § Voluntary measures ... safety and general welfare of

4.507.2 - Heating and Air-conditioning System

Chapter 4

Page 146: New Green Building Code Chapter 4 Residential Application · New Green Building Code Chapter 4 Residential Application ... § Voluntary measures ... safety and general welfare of

Questions

Page 147: New Green Building Code Chapter 4 Residential Application · New Green Building Code Chapter 4 Residential Application ... § Voluntary measures ... safety and general welfare of

Chapter 7Installer and Special Inspector Qualifications

Page 148: New Green Building Code Chapter 4 Residential Application · New Green Building Code Chapter 4 Residential Application ... § Voluntary measures ... safety and general welfare of

702.1 - Installer Training

§Establishes minimum requirements for heating and air conditioning installers.

Chapter 7

Page 149: New Green Building Code Chapter 4 Residential Application · New Green Building Code Chapter 4 Residential Application ... § Voluntary measures ... safety and general welfare of

702.1 - Installer Training

How to comply§Certification or training as a HVAC systems installer through a program acceptable to the enforcing agency.

§Work is performed under the direct supervision of a person with acceptable training.

Chapter 7

Page 150: New Green Building Code Chapter 4 Residential Application · New Green Building Code Chapter 4 Residential Application ... § Voluntary measures ... safety and general welfare of

702.1 - Installer Training

Certifications:§State certified apprenticeship programs

§Public utility training programs

§Training programs sponsored by trade, labor, statewide energy consulting or verification org.

§Manufactured sponsored programs

§Other programs acceptable to the enforcing agency

Chapter 7

Page 151: New Green Building Code Chapter 4 Residential Application · New Green Building Code Chapter 4 Residential Application ... § Voluntary measures ... safety and general welfare of

702.2 - Special Inspection

§Establishes minimum requirements for third party inspectors acting on behalf of the enforcing agency.

§Similar to structural special inspections.

Chapter 7

Page 152: New Green Building Code Chapter 4 Residential Application · New Green Building Code Chapter 4 Residential Application ... § Voluntary measures ... safety and general welfare of

702.2 - Special Inspection

How to comply§Demonstrate competence to the enforcing agency in the discipline being inspected.

§No financial interest in the project.

Chapter 7

Page 153: New Green Building Code Chapter 4 Residential Application · New Green Building Code Chapter 4 Residential Application ... § Voluntary measures ... safety and general welfare of

702.2 - Special Inspection

Certifications:§National or regional green building programs

§Statewide energy consulting org such as HERS, building performance contractors and home energy auditors

§Successful completion of a third party apprentice training program in the appropriate trade

§Other programs acceptable to the enforcing agency

Chapter 7

Page 154: New Green Building Code Chapter 4 Residential Application · New Green Building Code Chapter 4 Residential Application ... § Voluntary measures ... safety and general welfare of

Chapter 8Compliance Forms and Worksheets

§ Sample forms for construction waste management plans.

§ Water use worksheets.

§ More compliance forms will be added.

§ HCD is currently updating residential guide

Chapter 8

Page 155: New Green Building Code Chapter 4 Residential Application · New Green Building Code Chapter 4 Residential Application ... § Voluntary measures ... safety and general welfare of

Questions

Page 156: New Green Building Code Chapter 4 Residential Application · New Green Building Code Chapter 4 Residential Application ... § Voluntary measures ... safety and general welfare of

Appendix A4Residential

&Appendix A5

Nonresidential

Tiers

4/27/2011

Page 157: New Green Building Code Chapter 4 Residential Application · New Green Building Code Chapter 4 Residential Application ... § Voluntary measures ... safety and general welfare of

Meet mandatory requirements.

Meet prerequisites for each Chapter – as outlined in Appendix A4 (residential) and Appendix A5 (nonresidential).

Implement the required number of “elective” measures for each Chapter, as noted in A4 and A5.

Local jurisdiction sets final policy.

Reaching Tier 1 or Tier 2

Page 158: New Green Building Code Chapter 4 Residential Application · New Green Building Code Chapter 4 Residential Application ... § Voluntary measures ... safety and general welfare of

Appendix A4ResidentialVoluntary

Tiers

4/27/2011

Page 159: New Green Building Code Chapter 4 Residential Application · New Green Building Code Chapter 4 Residential Application ... § Voluntary measures ... safety and general welfare of

Tier 1 Prerequisites, Residential: examples

•Exceed CEC 2008 Energy Efficiency Standards by 15%

•65% reduction in construction waste

•20% permeable paving

•10% recycled content

•Cool roof – meet Tier 1 Solar Reflective Index requirement

•Reduced flow rate for kitchen sink faucets: max = 1.5 gallons per minute at 60 psi

•20% cement reduction

Page 160: New Green Building Code Chapter 4 Residential Application · New Green Building Code Chapter 4 Residential Application ... § Voluntary measures ... safety and general welfare of

Tier 1 Elective Requirements - Residential

At least two Planning and Design elective measures (Div A4.1)

At least four Energy Efficiency elective measures (Div A4.2)

At least one Water Efficiency and Conservation elective measure (Div A4.3)

At least two Material Conservation and Resource Efficiency elective measures from (Div A4.4)

At least one Environmental Quality elective measure (Div A4.5)

Page 161: New Green Building Code Chapter 4 Residential Application · New Green Building Code Chapter 4 Residential Application ... § Voluntary measures ... safety and general welfare of

Tier 1 Elective Requirements - Residential

Page 162: New Green Building Code Chapter 4 Residential Application · New Green Building Code Chapter 4 Residential Application ... § Voluntary measures ... safety and general welfare of

Tier 2: Note

The measures for Tier 2 status are very stringent.

Cities, counties and cities and counties considering adoption of Tier 2 as mandatory should carefully consider the stringency of each measure and ensure that the measures are achievable in their location.

Page 163: New Green Building Code Chapter 4 Residential Application · New Green Building Code Chapter 4 Residential Application ... § Voluntary measures ... safety and general welfare of

Tier 2 Prerequisites, Residential: examples

•Exceed CEC 2008 Energy Efficiency Standards by 30%

•75% reduction in construction waste

•30% permeable paving

•15% recycled content

•Cool roof – meet Tier 2 Solar Reflective Index requirement

•Reduced flow rate for kitchen sink faucets, dishwasher must be Energy Star compliant, 5.8 gals per cycle max.

•30% cement reduction

Page 164: New Green Building Code Chapter 4 Residential Application · New Green Building Code Chapter 4 Residential Application ... § Voluntary measures ... safety and general welfare of

Tier 2 Elective requirements, residential

§ At least four Planning and Design elective measures

§ At least six Energy Efficiency elective measures

§ At least two Water Efficiency and Conservation elective measures

§ At least four Material Conservation and Resource Efficiency elective measures

§ At least one Environmental Quality elective measure

Page 165: New Green Building Code Chapter 4 Residential Application · New Green Building Code Chapter 4 Residential Application ... § Voluntary measures ... safety and general welfare of

§ Meet all mandatory requirements.

§ Meet Tier 1 or Tier 2 prerequisites.

§ Comply with additional elective measures as follows:§ 10 electives for Tier 1§ 17 electives for Tier 2

§ Application Checklist§ Mandatory provisions§ Provisions required for compliance with tiers

Tiers – Residential Summary

Page 166: New Green Building Code Chapter 4 Residential Application · New Green Building Code Chapter 4 Residential Application ... § Voluntary measures ... safety and general welfare of

SECTION A4.6.2Residential Occupancies Application Checklist

Page 167: New Green Building Code Chapter 4 Residential Application · New Green Building Code Chapter 4 Residential Application ... § Voluntary measures ... safety and general welfare of

4/27/2011

www.aiacc.org

Page 168: New Green Building Code Chapter 4 Residential Application · New Green Building Code Chapter 4 Residential Application ... § Voluntary measures ... safety and general welfare of

Building Standards Commission

www.bsc.ca.gov

4/27/2011

Page 169: New Green Building Code Chapter 4 Residential Application · New Green Building Code Chapter 4 Residential Application ... § Voluntary measures ... safety and general welfare of

www.bsc.ca.gov

4/27/2011

Page 170: New Green Building Code Chapter 4 Residential Application · New Green Building Code Chapter 4 Residential Application ... § Voluntary measures ... safety and general welfare of

California Department of Housing and Community Development

www.hcd.ca.gov

4/27/2011

Page 171: New Green Building Code Chapter 4 Residential Application · New Green Building Code Chapter 4 Residential Application ... § Voluntary measures ... safety and general welfare of

California Department of Housing and Community Development

www.hcd.ca.gov

Residential Guide

Page 172: New Green Building Code Chapter 4 Residential Application · New Green Building Code Chapter 4 Residential Application ... § Voluntary measures ... safety and general welfare of

More Resources

4/27/2011

Whitepaper

Complimentary CALGreen WhitepaperProvides:

•Information for Cities, Architects,and Developers

•Current State information•Valuable resources•Assist with implementation ideas•Helps design professionals to met

city requirements

Email: [email protected]

Page 173: New Green Building Code Chapter 4 Residential Application · New Green Building Code Chapter 4 Residential Application ... § Voluntary measures ... safety and general welfare of

QuestionsTHANK YOU!

4/27/2011