Top Banner
McLaren Applied Technologies McLaren Technology Centre Chertsey Road Woking Surrey GU21 4YH UK McLaren Applied Technologies Suite 115 Bostick Building 9801 West Kincey Avenue Huntersville NC 28078 USA Phone: +44 (0)1483 261400 Fax: +44 (0)1483 261402 [email protected] www.mclaren.com/mat Phone: +001 (704) 660 3181 Fax: +001 (704) 660 8829 © McLaren Applied Technologies 2014 Revision Date: 22 Aug 2013 Page 1 of 3 E-Motor 120kW / 130Nm Product Summary
3

New E-Motor · 2014. 2. 17. · McLaren Applied Technologies McLaren Technology Centre Chertsey Road Woking Surrey GU21 4YH UK McLaren Applied Technologies Suite 115 Bostick Building

Oct 23, 2020

Download

Documents

dariahiddleston
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
  • McLaren Applied TechnologiesMcLaren Technology CentreChertsey RoadWokingSurreyGU21 4YHUK

    McLaren Applied TechnologiesSuite 115

    Bostick Building9801 West Kincey Avenue

    HuntersvilleNC 28078

    USA

    Phone: +44 (0)1483 261400Fax: +44 (0)1483 261402

    [email protected]/mat

    Phone: +001 (704) 660 3181Fax: +001 (704) 660 8829

    © McLaren Applied Technologies 2014 Revision Date: 22 Aug 2013 Page 1 of 3

    E-Motor120kW / 130Nm

    Product Summary

  • E-Motor120kW / 130Nm

    McLaren Applied Technologies USA: McLaren Applied Technologies

    Phone: +44 (0)1483 261400Fax: +44 (0)1483 261402

    [email protected]/mat

    Phone: +001 (704) 660 3181Fax: +001 (704) 660 8829

    © McLaren Applied Technologies 2014 Revision Date: 22 Aug 2013 Page 2 of 3

    The 120kW E-Motor is a synchronous permanent magnet motor/generator

    primarily intended for hybrid and electric vehicles. The unit is powered via

    a high voltage three-phase electrical connection from an inverter, such as

    McLaren Applied Technologies’ MCU-500.

    An advanced liquid cooling scheme allows the motor to achieve sustained

    high power operation given the unit’s modest size and weight.

    When combined with the MCU-500, and powered from a 535V DC bus, the

    unit can be controlled via torque and/or speed demands via a CAN bus. The

    same performance characteristics can be achieved in motor and generator

    modes of operation.

    Key Features

    • Permanent magnet synchronous motor

    • SPM type

    • High power density

    Performance

    • Power and torque:

    120kW / 130Nm (transient)

    110kW / 110Nm (continuous)

    • Maximum speed 17,000rpm

    • Efficiency 96% (120kW, 13,000rpm)

    Electrical

    • Input type: high voltage sinusoidal three-phase

    • Nominal bus voltage 545V

    • Maximum bus voltage 630V

    • Minimum bus voltage 420V (for full performance)

    • Leakage current

  • E-Motor120kW / 130Nm

    McLaren Applied Technologies USA: McLaren Applied Technologies

    Phone: +44 (0)1483 261400Fax: +44 (0)1483 261402

    [email protected]/mat

    Phone: +001 (704) 660 3181Fax: +001 (704) 660 8829

    © McLaren Applied Technologies 2014 Revision Date: 22 Aug 2013 Page 3 of 3

    Cooling

    • Max inlet temperature 55°C

    • Min flow-rate 20l/min

    • Pressure drop 0.6bar @ 20l/min

    • Coolant type 50/50 water/glycol

    • Max pressure 5bar

    Environmental

    • Air temperature:

    -20°C to 90°C (operating)

    -20°C to 120°C (static)

    • Max motor skin temperature 65°C

    • Rated to IP67

    • Maximum mounting vibration 30g

    • Complies with the essential protection requirements of 89/336/EEC

    Description Ordercode

    E-Motor-120kW O 030 525 000 001