1 © Travis Perkins plc 2011 6 digit product code unique to Travis Perkins Group www.sustainablebuildingsolutions.co.uk AERATED PART FILL D1B STANDARD CONSTRUCTION DRAWINGS NEW BUILD
1
© Travis Perkins plc 20116 digit product code unique to Travis Perkins Group
www.sustainablebuildingsolutions.co.uk
aerated Part filld1B
standard construction drawings
new Build
2
D1B - aerateD Part fillstanDarD construction Drawings
© travis Perkins plc 2011
www.sustainablebuildingsolutions.co.uk
welcome to
Sustainable Building Solutions (SBS) is a specialist division of the travis Perkins Group established in 2010 to provide help, support and expert technical assistance to the construction industry. SBS offers an integrated approach to providing solutions for your energy efficient Building and renewable energy projects. we provide the products, technical advice, specifications, services and training to enable you to complete any Sustainability project.
• Solutions – we offer new-build and retrofit energy efficient and compliant solutions, with a fabric first approach, supported through client and industry research.
• Services – we provide many services to help you deliver your project. for details please see page 29.
• Products – we provide a broad range of products, from Building fabric to water management, and from eco materials to renewable energy technologies.
• technical expertise – the SBS team has the support of an advisory Board which includes Bre and laBc.
for assistance on Sustainable Building Solutions and the products we offer, please contact :
Sustainable Building Sales Helpline: 0844 822 0700
email: [email protected]
www.sustainablebuildingsolutions.co.uk
travis Perkins plc is a leading company in the builders merchant and home improvement markets and is a main supplier to the building and construction market, one of the largest industries in the uK.
the group operates 19 businesses from more than 1,700 sites across the uK, which offer a wide range of products and services.
3
D1B - aerateD Part fillstanDarD construction Drawings
© travis Perkins plc 2011
contentS
2. Welcome to SBS
4. Welcome to Standard Construction Drawings
5. Our Approach
9. SBS 33.0 Aerated Part Fill Suspended I Beam Timber Eaves Cold Roof External
10. SBS 34.0 Aerated Part Fill Suspended I Beam Timber Eaves Habitable External
11. SBS 35.0 Aerated Part Fill Suspended I Beam Brick Eaves Cold Roof External
12. SBS 37.0 Aerated Part Fill Suspended I Beam Gable End Cold Roof External
13. SBS 39.0 Aerated Part Fill Suspended I Beam Timber Eaves Cold Roof External
14. SBS 40.0 Aerated Part Fill Suspended Solid Timber Eaves Habitable External
15. SBS 41.0 Aerated Part Fill Suspended Solid Brick Eaves Cold Roof External
16. SBS 43.0 Aerated Part Fill Suspended Solid Brick Eaves Cold Roof External
17. SBS 45.0 Aerated Part Fill Solid I Beam Timber Eaves Cold Roof External
18. SBS 46.0 Aerated Part Fill Solid I Beam Timber Eaves Habitable External
19. SBS 47.0 Aerated Part Fill Solid I Beam Brick Eaves Cold Roof External
20. SBS 49.0 Aerated Part Fill Solid I Beam Gable End Cold Roof External
21. SBS 51.0 Aerated Part Fill Solid Solid Timber Eaves Cold Roof External
22. SBS 52.0 Aerated Part Fill Solid Solid Timber Eaves Habitable External
23. SBS 53.0 Aerated Part Fill Solid I Beam Brick Eaves Cold Roof Party
24. SBS 55.0 Aerated Part Fill Solid Solid Gable End Cold Roof External
25. SBS Services
4
D1B - aerateD Part fillstanDarD construction Drawings
© travis Perkins plc 2011
www.sustainablebuildingsolutions.co.uk
welcome toStandard conStruction drawinGS (new Build)with building regulations changing every 3 years and the efficiency of buildings becoming a higher priority within these changes, achieving the right new-build or retrofit solution at an acceptable cost can be a challenge.
to help the construction industry reduce these costs we have produced a series of standard construction details which will help maximise the fabrics contribution in SaP.
d1a new Build aerated full filld1B new Build aerated Part filld1c new Build aggregate full filld1d new Build aggregate Part fill
each of the construction details uses standard construction techniques and materials, which are assembled in carefully planned detail to minimise the thermal conductivity.
WHy uSE THESE DETAIlS?Key benefits to users of these Standard construction drawings:
• Significantly reduced thermal conductivity
• requires very small simple changes to standard building methods
• no significant increase in build cost
• removes the need to use default SaP values
• independently verified by Bre and laBc
• available as cad drawings
• all products included in the Plans are specified and available from the travis Perkins Group with a unique 6 digit product code
• Saves time and cost for architects and contractors: architects can direct customers directly to travis Perkins for selected junctions
• regularly updated and future-proof through 2013 Building regulations
AvAIlABIlITythe entire series of details is available to purchase in dwG format for £50.
TO PuRCHASEcall 0844 822 0700.email your interest to [email protected] and we will call back within 48 hours.
5
D1B - aerateD Part fillstanDarD construction Drawings
© travis Perkins plc 2011
A/C A/C A/CBathroom BathroomBathroom
Bedroom 2 Bedroom 2 Bedroom 2
Bedroom 1Bedroom 1Bedroom 1
Landing Landing Landing
762
762/
762
762/
762
762/
762762/
762
762/
762762/
762
762/
762 762/
762
762/
3
2
1
4
5
6
7
8
9
10
11
12
3
2
1
4
5
6
7
8
9
10
11
12
3
2
1
4
5
6
7
8
9
10
11
12
Master Bedroom
Bath rm.
Landing
Bedrm 3
SD
E.E.L
E.E.L
E.E.LBedrm 2
En-suit
A/C
RWP
RWP RWP
RWP
mid terraced unit 80.3m2
end terraced unit 80.3m2
detached dwelling 113m2
our aPProacHthe approach we took to create the Standard construction details:
• Standard brick and block construction for the first details with a maximum 100mm cavity
• carefully analysed commercial case for all components, delivering the optimum balance of cost versus contribution to SaP
• developed the details and sections in 72 cross sections from foundation to just above the eaves
• with the help of the Bre selected 71 junctions to detail and model to show the biggest gain against the accredited values in appendix K within SaP 2009
• reduced our thermal bridging for the property and applied these in two test houses: a two-bedroom mid and end terrace of 80m2, and a three-bedroom detached property of 113m2
• tested and passed all details within SaP, across all building orientations around the compass, from north to South
all the following psi-values have been calculated by a suitably competent thermal bridging modeller using the conventions as set out in “Br 497 - conventions for calculating linear thermal transmittance and temperature factors”, and in accordance with “iP1/06 - assessing the effects of thermal bridging at junctions and around openings”, by the Bre.
6
D1B - aerateD Part fillstanDarD construction Drawings
© travis Perkins plc 2011
www.sustainablebuildingsolutions.co.uk
notes:ψ (w/mK) = linear thermal transmittanceProgramme used = PHYSiBel triSco 12.0 software as used by the Bre and following the conventions in Br497.
Accredited ψ (W/mK) Appendix K
Travis Perkins StandardDetails ψ (W/mK)
% Improvement
Gable wall - ceiling Junction
ψ 0.240 ψ 0.048 80%
Party wall - externalwall Junction
ψ 0.060 ψ 0.035 42%
window Head andlintel Junction
ψ 0.300 ψ 0.129 57%
intermediate floor - external wall Junction
ψ 0.070 -ψ 0.001 101%
Ground floor - external wall Junction
ψ 0.160 ψ 0.032 80%
Party wall -ceiling Junction
ψ 0.120 ψ 0.024 80%
Party wall - Groundfloor Junction
ψ 0.160 ψ 0.045 72%
imProvementS aGainSt SaPthe Standard construction drawings have generated substantial improvements against standard SaP accredited values for linear thermal transmittance and they far exceed any other values published.
the Standard construction details can only be submitted with the new ψ – values if the build is exactly as shown as using the products specified.
any deviation makes the figures void, including using products that have a better u-value.
7
D1B - aerateD Part fillstanDarD construction Drawings
© travis Perkins plc 2011
SaP 2009 reSultS for Partial fill witH aerated BlocKS and SuSPended floorS
Element House Type
version detached mid terrace end terrace
worst orientation,front facing
Sw or Se Sw or Se Sw/S/Se
walls 0.26 0.26 0.26
Party walls n/a 0.00 0.00
floors 0.14 (120mm Pir) 0.12 (120mm Pir) 0.13 (120mm Pir)
roof 0.10 0.10 0.10
window type, whole window u-value and glass glazing
d.G, 1.20 and 0.70 d.G, 1.20 and 0.70 d.G, 1.20 and 0.70
Patio/french doors d.G, 1.20 and 0.70 d.G, 1.20 and 0.70 d.G, 1.20 and 0.70
doors 1.80 1.80 1.80
detailing y-value 0.037 0.047 0.039
airtightness 6.0 5.0 5.0
ventilation natural and fans natural and fans natural and fans
Boiler –worcester Greenstar
24i system 89.2% eff. (SedBuK 2009)
12i systems 88.8% eff. (SedBuK 2009)
18i system 88.8% eff. (SedBuK 2009)
controls Programmer, thermostat and trv’s
Programmer, thermostat and trv’s
Programmer, thermostat and trv’s
Hw Store size/losses 180l / 1.40 kwh/day 120l / 1.00 kwh/day 120l / 1.00 kwh/day
SaP Q tech 1 n/a n/a n/a
SaP Q tech 2 n/a n/a n/a
ter SaP 2009 20.17 17.35 19.66
der SaP 2009 19.44 17.20 19.36
Percentage improvement achieved
3.62% 0.86% 1.53%
feeS 53.7 36.2 45.8
ene2 credits 4.4 7.7 7.0
annual running costs £397 £310 £334
SaP rating B82 B83 B82
ei rating B84 B87 B86
8
D1B - aerateD Part fillstanDarD construction Drawings
© travis Perkins plc 2011
www.sustainablebuildingsolutions.co.uk
SaP 2009 reSultS for full fill witH denSe BlocKS and Solid floorS
Element House Type
version detached mid terrace end terrace
worst orientation,front facing
Sw or Se Sw or Se Sw/S/Se
walls 0.26 0.26 0.26
Party walls n/a 0.00 0.00
floors 0.14 (120mm Pir) 0.11 (120mm Pir) 0.13 (120mm Pir)
roof 0.10 0.10 0.10
window type, whole window u-value and glass glazing
d.G, 1.20 and 0.70 d.G, 1.20 and 0.70 d.G, 1.20 and 0.70
Patio/french doors d.G, 1.20 and 0.70 d.G, 1.20 and 0.70 d.G, 1.20 and 0.70
doors 1.80 1.80 1.80
detailing y-value 0.038 0.047 0.037
airtightness 6.0 5.0 5.0
ventilation natural and fans natural and fans natural and fans
Boiler –worcester Greenstar
24i system 89.2% eff. (SedBuK 2009)
12i systems 88.8% eff. (SedBuK 2009)
18i system 88.8% eff. (SedBuK 2009)
controls Programmer, thermostat and trv’s
Programmer, thermostat and trv’s
Programmer, thermostat and trv’s
Hw Store size/losses 180l / 1.40 kwh/day 120l / 1.00 kwh/day 120l / 1.00 kwh/day
SaP Q tech 1 n/a n/a n/a
SaP Q tech 2 n/a n/a n/a
ter SaP 2009 20.17 17.35 19.66
der SaP 2009 19.47 17.14 19.31
Percentage improvement achieved
3.47% 1.21% 1.78%
feeS 53.8 35.8 45.5
ene2 credits 4.4 7.8 7.1
annual running costs £398 £309 £333
SaP rating B82 B83 B82
ei rating B84 B87 B86
9
D1B - aerateD Part fillstanDarD construction Drawings
6 digit product code unique to travis Perkins group © travis Perkins plc 2011
SBS 33.0aerated BlockPart fill cavitySuspended Ground floori Beam intermediate floortimber eaves detailcold roofexternal wall
10
D1B - aerateD Part fillstanDarD construction Drawings
© travis Perkins plc 20116 digit product code unique to travis Perkins group
www.sustainablebuildingsolutions.co.uk
SBS 34.0aerated BlockPart fill cavitySuspended Ground floori Beam intermediate floortimber eaves detailHabitable roofexternal wall
11
D1B - aerateD Part fillstanDarD construction Drawings
6 digit product code unique to travis Perkins group © travis Perkins plc 2011
SBS 35.0aerated BlockPart fill cavitySuspended Ground floori Beam intermediate floorBrick eaves detailcold roofexternal wall
12
D1B - aerateD Part fillstanDarD construction Drawings
© travis Perkins plc 20116 digit product code unique to travis Perkins group
www.sustainablebuildingsolutions.co.uk
SBS 37.0aerated BlockPart fill cavitySuspended Ground floori Beam intermediate floorGable endcold roofexternal wall
120mm PIR Insulation (778050)
Wall Tie(260703 + 252302)
Aerated Block(700055)
Concrete Floor Beams
Sand BlindingVCL (921090)
65mm Sand & Cement Screed
Mastic Seal(879428)
Skirting Board
Aerated Floor Block(201272)
Plasterboard 12.5mm
DPM (920484)
DPC(780227)
Facing Brick
150mm min
30mm
Aerated Foundation Block(878251)
Aerated Block(753178)
Cranked Vent and Air Brick(916445) & (916425)
Radiator Pipe Guide & Seal(497439)
PIR Insulation upstand (778036)
50mm PIR Insulation(778064)
Ψ 0.037 W/mK
4002 mm
12.5mm Plasterboard
100mm Loft Roll betweenRafters (114792)
300mm Loft Roll(2 x 114793)
Decorating Caulk (879422)
Roo�ng Battens
Breathable Roo�ng Felt(652159)
Roo�ng Tiles
Ψ 0.129 W/mK
Eaves Vent(917403)
Felt support(504053)
Over Insulation Ventilator(916129)
15mm Plasterboard
Skirting Board
Mastic Seal(879428)
Timber Joists
22mm Chipboard Flooring(165363)
Decorating Caulk(879422)
Decorating Caulk(879422)
Cavity Closer(936087 + 962997)
Window with minimumU-value of 1.2W/m2K
100mm Insulation(122528)
Ψ -0.006 W/mK
©
13
D1B - aerateD Part fillstanDarD construction Drawings
6 digit product code unique to travis Perkins group © travis Perkins plc 2011
SBS 39.0aerated BlockPart fill cavitySuspended Ground floortimber intermediate floortimber eaves detailcold roofexternal wall
14
D1B - aerateD Part fillstanDarD construction Drawings
© travis Perkins plc 20116 digit product code unique to travis Perkins group
www.sustainablebuildingsolutions.co.uk
SBS 40.0aerated BlockPart fill cavitySuspended Ground floortimber intermediate floortimber eaves detailHabitable roofexternal wall
15
D1B - aerateD Part fillstanDarD construction Drawings
6 digit product code unique to travis Perkins group © travis Perkins plc 2011
SBS 41.0aerated BlockPart fill cavitySuspended Ground floortimber intermediate floorBrick eaves detailcold roofexternal wall
16
D1B - aerateD Part fillstanDarD construction Drawings
© travis Perkins plc 20116 digit product code unique to travis Perkins group
www.sustainablebuildingsolutions.co.uk
SBS 43.0aerated BlockPart fill cavitySuspended Ground floortimber intermediate floorGable endcold roofexternal wall
17
D1B - aerateD Part fillstanDarD construction Drawings
6 digit product code unique to travis Perkins group © travis Perkins plc 2011
SBS 45.0aerated BlockPart fill cavitySolid concrete Ground floori Beam intermediate floortimber eaves detail cold roofexternal wall
18
D1B - aerateD Part fillstanDarD construction Drawings
© travis Perkins plc 20116 digit product code unique to travis Perkins group
www.sustainablebuildingsolutions.co.uk
SBS 46.0aerated BlockPart fill cavitySolid concrete Ground floori Beam intermediate floortimber eaves detailHabitable roofexternal wall
19
D1B - aerateD Part fillstanDarD construction Drawings
6 digit product code unique to travis Perkins group © travis Perkins plc 2011
SBS 47.0aerated BlockPart fill cavitySolid concrete Ground floori Beam intermediate floorBrick eaves detailcold roofexternal wall
20
D1B - aerateD Part fillstanDarD construction Drawings
© travis Perkins plc 20116 digit product code unique to travis Perkins group
www.sustainablebuildingsolutions.co.uk
SBS 49.0aerated BlockPart fill cavitySolid concrete Ground floori Beam intermediate floorGable endcold roofexternal wall
21
D1B - aerateD Part fillstanDarD construction Drawings
6 digit product code unique to travis Perkins group © travis Perkins plc 2011
SBS 51.0aerated BlockPart fill cavitySolid concrete Ground floortimber intermediate floortimber eaves detailcold roofexternal wall
22
D1B - aerateD Part fillstanDarD construction Drawings
© travis Perkins plc 20116 digit product code unique to travis Perkins group
www.sustainablebuildingsolutions.co.uk
SBS 52.0aerated BlockPart fill cavitySolid concrete Ground floortimber intermediate floortimber eaves detailHabitable roofexternal wall
23
D1B - aerateD Part fillstanDarD construction Drawings
6 digit product code unique to travis Perkins group © travis Perkins plc 2011
SBS 53.0aerated BlockPart fill cavitySolid concrete Ground floortimber intermediate floorBrick eaves detailcold roofexternal wall
24
D1B - aerateD Part fillstanDarD construction Drawings
© travis Perkins plc 20116 digit product code unique to travis Perkins group
www.sustainablebuildingsolutions.co.uk
SBS 55.0aerated BlockPart fill cavitySolid concrete Ground floortimber intermediate floorGable endcold roofexternal wall
25
D1B - aerateD Part fillstanDarD construction Drawings
© travis Perkins plc 2011
SuStainaBle BuildinGHelPlinethe travis Perkins Group has partnered with Bre to provide a free Sustainable Building Helpline to help the uK construction industry.
tel: 0800 6888 388
ServiceS to HelP You deliver Your SuStainaBle ProJect
inStaller traininG courSeS
SBS has partnered with PPl training to provide a range of renewables and Sustainability training courses.
the qualifications offered are from uKcaS accredited awarding bodies such as city & Guilds, Bpec and niceic certification. they are recognised, where appropriate, for registration with competent Persons Schemes (cPS) and the microgeneration certification Scheme (mcS).
PPl has training locations throughout the uK. for Groups, PPl can run courses at branches of any of the 19 travis Perkins Group companies.
for more details visit www.sustainablebuildingsolutions.co.uk or call 0845 2600 967
26
D1B - aerateD Part fillstanDarD construction Drawings
© travis Perkins plc 2011
www.sustainablebuildingsolutions.co.uk
Site SurveY & teStinG many new technologies require specific knowledge and experience to design the best system to meet the needs of the end user.
the aim of these services is to provide optimised, high performance systems that prevent unnecessary expense and delivers the best value for money.
tailoring a solution that properly takes account of ground conditions and site constraints will provide long-term efficiencies.
• Ground Source Heat Pumps Surveying
• Sustainable drainage design
for more details visit www.sustainablebuildingsolutions.co.uk or call 01273 699406
BuildinG control & teStinG a simple one-stop-shop to help developers and contractors in meeting the wide range of statutory obligations imposed by the Building regulations.
the services can be ordered individually, in groups, or expanded to a full consultancy service.
• energy assessment for SaP
• code for Sustainable Homes assessment
• Building control compliance
• environment assessment
• air tightness testing
• acoustic testing
for more details visit www.sustainablebuildingsolutions.co.uk or call 0845 680 9882
27
D1B - aerateD Part fillstanDarD construction Drawings
© travis Perkins plc 2011
renewaBleS HeatinG deSiGndesigning the optimum renewables system for a particular site can be challenging for end users and installers. the experts at SBS can help you by providing a detailed system plan, and product list, to help deliver the most efficient solution for your building.
Services include:
• Solar thermal System design
• Solar thermal Site Plan
• air Source Heat Pumps
• Heating design
• Hot & cold water System design
• central Heating System design
for more details visit www.sustainablebuildingsolutions.co.uk
ePc certification this fixed cost service provides an energy Performance certificate (ePc) which isrequired when a dwelling is either being built, rented out or sold. it can be ordered as a sole service, or as part of a package of Building control services.
for more details visit www.sustainablebuildingsolutions.co.uk orcall 0845 680 9882
www.sustainablebuildingsolutions.co.uk
contact information
For sales enquiries:
0844 822 0700
Expert technical advice:
0800 6888 388
Email:
www.sustainablebuildingsolutions.co.uk
registered office: Lodge way House, Lodge way, northampton. nn5 7ugregistered in England 824821the information contained in this publication is believed to be correct and complete at the time of printing. due to limitations in the printing process images may not be representative of their true colours and colour variations may occur due to the natural origin of the products. stock may vary from branch to branch and is subject to availability. all photographs are as a guide only and do not necessarily represent the products available. travis Perkins plc reserves the right to change product details without prior notice. Errors & omissions excluded. all products sold subject to travis Perkins terms & conditions of sale. travis Perkins plc is the owner of the registered trademark travis Perkins. JB65008 12/11