1 3 79720-0033 GHE CLEAN LINE PIPE SPOOL - THRU TRENCH TO DISTRIBUTION - - 6 2 79720-0024 GHE CLEAN LINE INTAKE SPOOL ASSY - - 1 1 79720-0023 GHE CLEAN LINE MAIN HEADER PIPE SPOOL - - QTY REQD ITEM NO. PART OR IDENTIFYING NO. NOMENCLATURE OR DESCRIPTION MATERIAL SPECIFICATION NOTES PARTS LIST QTY REQD NOMENCLATURE OR DESCRIPTION QTY REQD NOTES ITEM NO. PARTS LIST MATERIAL SPECIFICATION PART OR IDENTIFYING NO. \ .XX \ .X \ \ .XXX \ REV. C C 7 7 6 6 5 5 4 4 3 3 2 8 8 D B A D B A 1 2 1 REVISION HISTORY ZONE REV DESCRIPTION DATE APPROVED THIRD ANGLE PROJECTION MATERIAL DEBURR & BREAK ALL SHARP EDGES DO NOT SCALE DRAWING SHEET OF USED ON ASSY NO. SCALE DWG. NO. SIZE DRAWN D 1 1 United States Department of Energy Newport News Virginia DIM & TOL PER ASME Y14.5. UNLESS OTHERWISE SPECIFIED DIMENSIONS ARE IN INCHES. FRACTIONS DECIMAL ANGLES FINISH MACHINE SURFACES UNLESS OTHERWISE NOTED DATE TOLERANCES ARE: LCLS-II STORAGE WARM He GHe CLEAN LINE PIPING ARRANGEMENT 79720-0012 - NONE 79720-0010 SEE PARTS LIST 125 T. CRAHAN 28APR17 N/A .1 .01 .005 .50` ISOMETRIC VIEW 3 2 1 TYP CONTINUE TO 79120-2017 (ON 79120-0028, CP1 NORTH SLAB) RESTRICTIVE NOTICE: These designs and drawings were prepared by Jefferson Science Associates, LLC, hereinafter the Contractor, under Contract No. DE-AC05-06OR23177 with the Department of Energy (DOE). All rights in the designs and drawings are reserved by DOE on behalf of the United States Government and the Contractor as provided in the Contract. You are authorized to use these works for Governmental purposes but it is not to be released or distributed to the public. NEITHER THE GOVERNMENT NOR THE CONTRACTOR MAKES ANY WARRANTY, EXPRESS OR IMPLIED, OR ASSUMES ANY LIABILITY FOR THE USE OF THESE DESIGNS OR DRAWINGS. (This notice including this sentence must appear on any copies of these designs or drawings.) DETAIL A DETAIL A TYP 6X 1) ALL PRESSURE BOUNDARY WELDS SHALL BE MADE, EXAMINED, INSPECTED AND TESTED PER APPLICABLE ASME B31.3 REQUIREMENTS. THE GHE CLEAN LINE IS A NORMAL SERVICE SYSTEM. 2) SEE SPOOL DRAWINGS FOR SERVICE, DESIGN PARAMETERS AND LEAK TEST METHOD / PRESSURE. REFER TO STATEMENT OF WORK FOR LEAK TESTING DETAILS. LEAK TEST PIPES PRIOR TO FASTENING TO SUPPORTS. 3) CLEAN AND PREPARE COMPONENTS PER PROJECT STATEMENT OF WORK. PIPE SPOOLS AND COMPONENTS SHALL BE PROTECTED FROM DAMAGE AND CONTAMINATION AT ALL TIMES, INCLUDING CAPPING OPEN PIPE ENDS WHEN NOT BEING WORKED AND APPLYING PROTECTIVE COVERS TO FLANGE FACES. 4) DIMENSIONS ARE NOMINAL, FABRICATOR TO VERIFY ALL DIMENSIONS PRIOR TO THE START OF FABRICATION. 5) P&ID 79720-0000 IS ASSOCIATED WITH THIS PIPING ASSEMBLY. THIS ASSEMBLY BELONGS TO PRESSURE SYSTEM 79720-PS-002. 6) TEE AND ELBOW LOCATIONS SET BY AS-BUILT LOCATIONS OF TRENCH AND ASSOCIATED CONNECTIONS ON THE HELIUM STORAGE TANKS. 7) TAG NUMBERS FOR COMPONENTS USED IN CRYOGENIC PLANT #1 SHALL BE LABELED WITH A PREFIX OF "C1", TAG NUMBERS FOR COMPONENTS USED IN CRYOGENIC PLANT #2 SHALL BE LABELED WITH A PREFIX OF "C2". COMPONENTS COMMON TO BOTH CRYOGENIC PLANTS SHALL BE LABELED WITH A PREFIX OF "C". 8) ALL COMPONENTS ON THIS DRAWING ARE COMMON TO BOTH CRYOGENIC PLANTS. 9) INTERFACE WITH GFP(E) HE GAS STORAGE TANK (79720-0021). SEE 79720-0021 FOR INTERFACE DEMOLITION DETAILS. SEE 79720-0010 FOR INTERFACE CONNECTION DETAILS. 7,8 7,8 7,8 7,8 7,8 7,8 HE-011 9 HE-021 HE-031 HE-041 HE-051 HE-061 9 9 9 9 9 EV11103 EV11203 EV11303 EV11403 EV11503 EV11603 Approved: 5/2/2017; E-Sign ID : 342096; signed by: Ap. 1: S. Kaminski; Ap. 2: M. Bevins; C.: P. Hansen; D: T. Fuell | GC PACKAGE 100% FOR REVIEW
10
Embed
New Approved: 5/2/2017; E-Sign ID : 342096; signed by: Ap. 1: S. … · 2017. 6. 1. · elbow 90 deg, 2 nps sch-10 lr, bw asme b16.9 astm a403-wp304/304l-1 2 - tee reducing, 3 x 2
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
1 3 79720-0033 GHE CLEAN LINE PIPE SPOOL -THRU TRENCH TO DISTRIBUTION - -
6 2 79720-0024 GHE CLEAN LINE INTAKE SPOOLASSY - -
1 1 79720-0023 GHE CLEAN LINE MAIN HEADERPIPE SPOOL - -
QTYREQD
ITEMNO.
PART ORIDENTIFYING NO.
NOMENCLATUREOR DESCRIPTION
MATERIALSPECIFICATION NOTES
PARTS LIST
QTYREQD
NOMENCLATUREOR DESCRIPTION
QTYREQD NOTESITEM
NO.
PARTS LIST
MATERIALSPECIFICATION
PART ORIDENTIFYING NO.
\.XX \.X \\
.XXX \
REV.
CC
7
7
6
6
5
5
4
4
3
3 2
8
8
D
B
A
D
B
A
12
1
REVISION HISTORY
ZONE REV DESCRIPTION DATE APPROVED
THIRD ANGLE PROJECTION
MATERIAL
DEBURR & BREAK ALL SHARP EDGES
DO NOT SCALE DRAWING
SHEET OFUSED ON ASSY NO.SCALE
DWG. NO.SIZE
DRAWND
1 1
United States Department of Energy
Newport News Virginia
DIM & TOL PER ASME Y14.5. UNLESS OTHERWISE SPECIFIEDDIMENSIONS ARE IN INCHES.
FRACTIONS DECIMAL ANGLES
FINISHMACHINE
SURFACES
UNLESSOTHERWISE
NOTED
DATE
TOLERANCES ARE:
LCLS-IISTORAGEWARM He
GHe CLEAN LINE PIPING ARRANGEMENT
79720-0012 -NONE 79720-0010
SEE PARTS LIST
125
T. CRAHAN 28APR17
N/A .1.01.005
.50`
ISOMETRIC VIEW
3
2
1
TYP
CONTINUE TO 79120-2017(ON 79120-0028,CP1 NORTH SLAB)
REST
RICTIV
E NOT
ICE:
The
se d
esign
s and
dra
wing
s wer
e pre
pare
d by
Jef
fers
on S
cienc
e As
socia
tes,
LLC,
her
eina
fter t
he C
ontra
ctor
, und
er C
ontra
ct No
. DE-
AC05
-06OR
2317
7 with
the
Depa
rtmen
t of E
nerg
y (DO
E). A
ll rig
hts
in th
e de
signs
and d
rawi
ngs
are
rese
rved
by D
OE o
n be
half
of th
e Un
ited
Stat
es G
overn
ment
and
the
Cont
ract
or a
s pr
ovide
d in
the
Cont
ract
. You
are
aut
horiz
ed to
use
thes
e wo
rks
for G
over
nmen
tal pu
rpos
es b
ut it
is n
ot to
be
relea
sed
or d
istri
bute
d to
the
publ
ic. N
EITHE
R TH
E GOV
ERNM
ENT N
OR TH
E CON
TRAC
TOR M
AKES
ANY W
ARRA
NTY,
EXPR
ESS O
R IM
PLIE
D, O
R ASS
UMES
ANY L
IABI
LITY
FOR T
HE US
E OF T
HESE
DESIG
NS O
R DRA
WING
S. (T
his
notic
e in
cludi
ng th
is se
nten
ce m
ust a
ppea
r on
any c
opies
of t
hese
des
igns
or d
rawi
ngs.
)
DETAIL A
DETAIL A
TYP
6X
1) ALL PRESSURE BOUNDARY WELDS SHALL BE MADE, EXAMINED, INSPECTED AND TESTED PER APPLICABLE ASME B31.3 REQUIREMENTS. THE GHE CLEAN LINE IS A NORMAL SERVICE SYSTEM.
2) SEE SPOOL DRAWINGS FOR SERVICE, DESIGN PARAMETERS AND LEAK TEST METHOD / PRESSURE. REFER TO STATEMENT OF WORK FOR LEAK TESTING DETAILS. LEAK TEST PIPES PRIOR TO FASTENING TO SUPPORTS.
3) CLEAN AND PREPARE COMPONENTS PER PROJECT STATEMENT OF WORK. PIPE SPOOLS AND COMPONENTS SHALL BE PROTECTED FROM DAMAGE AND CONTAMINATION AT ALL TIMES, INCLUDING CAPPING OPEN PIPE ENDS WHEN NOT BEING WORKED AND APPLYING PROTECTIVE COVERS TO FLANGE FACES.
4) DIMENSIONS ARE NOMINAL, FABRICATOR TO VERIFY ALL DIMENSIONS PRIOR TO THE START OF FABRICATION.
5) P&ID 79720-0000 IS ASSOCIATED WITH THIS PIPING ASSEMBLY. THIS ASSEMBLY BELONGS TO PRESSURE SYSTEM 79720-PS-002.
6) TEE AND ELBOW LOCATIONS SET BY AS-BUILT LOCATIONS OF TRENCH AND ASSOCIATED CONNECTIONS ON THE HELIUM STORAGE TANKS.
7) TAG NUMBERS FOR COMPONENTS USED IN CRYOGENIC PLANT #1 SHALL BE LABELED WITH A PREFIX OF "C1", TAG NUMBERS FOR COMPONENTS USED IN CRYOGENIC PLANT #2 SHALL BE LABELED WITH A PREFIX OF "C2". COMPONENTS COMMON TO BOTH CRYOGENIC PLANTS SHALL BE LABELED WITH A PREFIX OF "C".
8) ALL COMPONENTS ON THIS DRAWING ARE COMMON TO BOTH CRYOGENIC PLANTS.
9) INTERFACE WITH GFP(E) HE GAS STORAGE TANK (79720-0021). SEE 79720-0021 FOR INTERFACE DEMOLITION DETAILS. SEE 79720-0010 FOR INTERFACE CONNECTION DETAILS.
7,8
7,8
7,8
7,8
7,8
7,8
HE-011
9HE-021
HE-031
HE-041
HE-051
HE-061
9
9
9
9
9
EV11103
EV11203
EV11303
EV11403
EV11503
EV11603 Approved: 5/2/2017; E-Sign ID : 342096; signed by: Ap. 1: S. Kaminski; Ap. 2: M. Bevins; C.: P. Hansen; D: T. Fuell |
GC PACKAGE 100% FOR REVIEW
\.XX \.X \\
.XXX \
REV.
CC
7
7
6
6
5
5
4
4
3
3 2
8
8
D
B
A
D
B
A
12
1
REVISION HISTORY
ZONE REV DESCRIPTION DATE APPROVED
THIRD ANGLE PROJECTION
MATERIAL
DEBURR & BREAK ALL SHARP EDGES
DO NOT SCALE DRAWING
SHEET OFUSED ON ASSY NO.SCALE
DWG. NO.SIZE
DRAWND
1 1
United States Department of Energy
Newport News Virginia
DIM & TOL PER ASME Y14.5. UNLESS OTHERWISE SPECIFIEDDIMENSIONS ARE IN INCHES.
6 2 79720-0028 GHE PURIFIER DISCHARGEUPPER SPOOL ASSY - -
1 1 79720-0027 GHE PURIFIER DISCHARGEHEADER SPOOL ASSY - -
QTYREQD
ITEMNO.
PART ORIDENTIFYING NO.
NOMENCLATUREOR DESCRIPTION
MATERIALSPECIFICATION NOTES
PARTS LIST
2
1
3
ISOMETRIC VIEW
TYP
CONTINUE FROM79120-2017 (ON 79120-0028, CP1,NORTH SLAB)
REST
RICTIV
E NOT
ICE:
The
se d
esign
s and
dra
wing
s wer
e pre
pare
d by
Jef
fers
on S
cienc
e As
socia
tes,
LLC,
her
eina
fter t
he C
ontra
ctor
, und
er C
ontra
ct No
. DE-
AC05
-06OR
2317
7 with
the
Depa
rtmen
t of E
nerg
y (DO
E). A
ll rig
hts
in th
e de
signs
and d
rawi
ngs
are
rese
rved
by D
OE o
n be
half
of th
e Un
ited
Stat
es G
overn
ment
and
the
Cont
ract
or a
s pr
ovide
d in
the
Cont
ract
. You
are
aut
horiz
ed to
use
thes
e wo
rks
for G
over
nmen
tal pu
rpos
es b
ut it
is n
ot to
be
relea
sed
or d
istri
bute
d to
the
publ
ic. N
EITHE
R TH
E GOV
ERNM
ENT N
OR TH
E CON
TRAC
TOR M
AKES
ANY W
ARRA
NTY,
EXPR
ESS O
R IM
PLIE
D, O
R ASS
UMES
ANY L
IABI
LITY
FOR T
HE US
E OF T
HESE
DESIG
NS O
R DRA
WING
S. (T
his
notic
e in
cludi
ng th
is se
nten
ce m
ust a
ppea
r on
any c
opies
of t
hese
des
igns
or d
rawi
ngs.
)
DETAIL A
DETAIL A
TYP
6X
9
9
9
9
7,8
7,8
7,8
7,8
HE-012
HE-022
HE-032
HE-042
HE-052
HE-062
9
9
7,8
7,8
NOTES:
1) ALL PRESSURE BOUNDARY WELDS SHALL BE MADE, EXAMINED, INSPECTED AND TESTED PER APPLICABLE ASME B31.3 REQUIREMENTS. THE GHE PURIFIER DISCHARGE IS A NORMAL SERVICE SYSTEM.
2) SEE SPOOL DRAWINGS FOR SERVICE, DESIGN PARAMETERS AND LEAK TEST METHOD/PRESSURE. REFER TO STATEMENT OF WORK FOR LEAK TESTING DETAILS. LEAK TEST PIPES PRIOR TO FASTENING TO SUPPORTS.
3) CLEAN AND PREPARE COMPONENTS PER PROJECT STATEMENT OF WORK. PIPE SPOOLS AND COMPONENTS SHALL BE PROTECTED FROM DAMAGE AND CONTAMINATION AT ALL TIMES, INCLUDING CAPPING OPEN PIPE ENDS WHEN NOT BEING WORKED AND APPLYING PROTECTIVE COVERS TO FLANGE FACES.
4) DIMENSIONS ARE NOMINAL FABRICATOR TO VERIFY ALL DIMENSIONS PRIOR TO THE START OF FABRICATION.
5) P&ID 79720-0000 IS ASSOCIATED WITH THIS PIPING ASSEMBLY. THIS ASSEMBLY BELONGS TO PRESSURE SYSTEM 79720-PS-002.
6) TEE AND ELBOW LOCATIONS SET BY AS-BUILT LOCATIONS OF TRENCH AND ASSOCIATED CONNECTIONS ON THE HELIUM STORAGE TANKS.
7) TAG NUMBERS FOR COMPONENTS USED IN CRYOGENIC PLANT #1 SHALL BE LABELED WITH A PREFIX OF "C1", TAG NUMBERS FOR COMPONENTS USED IN CRYOGENIC PLANT #2 SHALL BE LABELED WITH A PREFIX OF "C2". COMPONENTS COMMON TO BOTH CRYOGENIC PLANTS SHALL BE LABELED WITH A PREFIX OF "C".
8) ALL COMPONENTS ON THIS DRAWING ARE COMMON TO BOTH CRYOGENIC PLANTS.
9) INTERFACE WITH GFP(E) HE GAS STORAGE TANK (79720-0021). SEE 79720-0021 FOR INTERFACE DEMOLITION DETAILS. SEE 79720-0010 FOR INTERFACE CONNECTION DETAILS.
EV11102
EV11202
EV11302
EV11402
EV11502
EV11602 Approved: 5/2/2017; E-Sign ID : 342100; signed by: Ap. 1: S. Kaminski; Ap. 2: M. Bevins; C.: P. Hansen; D: T. Fuell |
DIM & TOL PER ASME Y14.5 2009. UNLESS OTHERWISE SPECIFIEDDIMENSIONS ARE IN INCHES.TOLERANCES ARE:FRACTIONS DECIMAL ANGLES
\.XX \.X \\
.XXX \
REV.
CC
7
7
6
6
5
5
4
4
3
3 2
8
8
D
B
A
D
B
A
12
1
REVISION HISTORY
ZONE REV DESCRIPTION
THIRD ANGLE PROJECTION
MATERIAL
DEBURR & BREAK ALL SHARP EDGES
DO NOT SCALE DRAWING
SHEET OFUSED ON ASSY NO.SCALE
DWG. NO.SIZE
DRAWND
1 1
United States Department of Energy
Newport News Virginia
FINISHMACHINE
SURFACES
UNLESSOTHERWISE
NOTED
DATE
DATE/REVISER
DIM & TOL PER ASME Y14.5 2009. UNLESS OTHERWISE SPECIFIEDDIMENSIONS ARE IN INCHES.TOLERANCES ARE:FRACTIONS DECIMAL ANGLES
NOTES:
3'-6"
ISOMETRIC VIEW
5
2
4
1
1
3
6
3
1
1138"
3'-10 516"
1
1/8BOTH ENDS
TYP
REST
RICTIV
E NOT
ICE:
The
se d
esign
s and
dra
wing
s wer
e pre
pare
d by
Jef
fers
on S
cienc
e As
socia
tes,
LLC,
her
eina
fter t
he C
ontra
ctor
, und
er C
ontra
ct No
. DE-
AC05
-06OR
2317
7 with
the
Depa
rtmen
t of E
nerg
y (DO
E). A
ll rig
hts
in th
e de
signs
and d
rawi
ngs
are
rese
rved
by D
OE o
n be
half
of th
e Un
ited
Stat
es G
overn
ment
and
the
Cont
ract
or a
s pr
ovide
d in
the
Cont
ract
. You
are
aut
horiz
ed to
use
thes
e wo
rks
for G
over
nmen
tal pu
rpos
es b
ut it
is n
ot to
be
relea
sed
or d
istri
bute
d to
the
publ
ic. N
EITHE
R TH
E GOV
ERNM
ENT N
OR TH
E CON
TRAC
TOR M
AKES
ANY W
ARRA
NTY,
EXPR
ESS O
R IM
PLIE
D, O
R ASS
UMES
ANY L
IABI
LITY
FOR T
HE US
E OF T
HESE
DESIG
NS O
R DRA
WING
S. (T
his
notic
e in
cludi
ng th
is se
nten
ce m
ust a
ppea
r on
any c
opies
of t
hese
des
igns
or d
rawi
ngs.
)
1) ALL PRESSURE BOUNDARY WELDS SHALL BE MADE, EXAMINED, INSPECTED AND TESTED PER APPLICABLE ASME B31.3 REQUIREMENTS. THIS SYSTEM IS DESIGNATED:NORMAL SERVICE 2) FLUID HELIUM DESIGN PRESSURE=320 PSIG. DESIGN TEMPERATURE=30 F MIN TO 120 F MAX
3) CLEAN AND PREPARE COMPONENTS PER PROJECT STATEMENT OF WORK. PIPE SPOOLS AND COMPONENTS SHALL BE PROTECTED FROM DAMAGE AND CONTAMINATION AT ALL TIMES, INCLUDING CAPPING OPEN PIPE ENDS WHEN NOT BEING WORKED AND APPLYING PROTECTIVE COVERS TO FLANGE FACES.
4) REFER TO STATEMENT OF WORK FOR LEAK TESTING DETAILS. PERMITTED LEAK TEST FOR THIS ASSEMBLY IS A PNEUMATIC TEST AT 352 PSIG. 5) DIMENSIONS ARE NOMINAL, FABRICATOR TO VERIFY ALL DIMENSIONS PRIOR TO THE START OF FABRICATION.
6) PRINT THE DRAWING ASSEMBLY NUMBER ON EACH SPOOL SEGMENT PIPE SURFACE USING INDELIBLE INK.
7) DRAIN TEE LOCATION SET BY AS-BUILT LOCATION OF ASSOCIATED CONNECTION ON THE HELIUM STORAGE TANKS.
8) TAG NUMBERS FOR COMPONENTS USED IN CRYOGENIC PLANT #1 SHALL BE LABELED WITH A PREFIX OF "C1", TAG NUMBERS FOR COMPONENTS USED IN CRYOGENIC PLANT #2 SHALL BE LABELED WITH A PREFIX OF "C2". COMPONENTS COMMON TO BOTH CRYOGENIC PLANTS SHALL BE LABELED WITH A PREFIX OF "C".
9) ALL COMPONENTS ON THIS DRAWING ARE COMMON TO BOTH CRYOGENIC PLANTS.
10) TAG NUMBERS THAT ARE TYPICAL TO MORE THAN ONE LOCATION USE X TO INDICATE THE CHARACTER THAT VARIES BY LOCATION. IN THIS APPLICATION, X IS EQUAL TO THE LAST DIGIT IN THE TAG NUMBER OF THE ASSOCIATED GAS HELIUM STORAGE TANK
EV11X04
10
9
6
3'-034"
8 Approved: 5/2/2017; E-Sign ID : 342103; signed by: Ap. 1: S. Kaminski; Ap. 2: M. Bevins; C.: P. Hansen; D: T. Fuell |
DIM & TOL PER ASME Y14.5. UNLESS OTHERWISE SPECIFIEDDIMENSIONS ARE IN INCHES.
FRACTIONS DECIMAL ANGLES
FINISHMACHINE
SURFACES
UNLESSOTHERWISE
NOTED
DATE
TOLERANCES ARE:
LCLS-IISTORAGEWARM He
GHe CLEAN LINE MAIN HEADER PIPE SPOOL
79720-0023 -NONE 79720-0012
SEE NOTES
125
T. CRAHAN 1 MAR 16
1/16 .1.01.005
.50`
6
5
2
14'-858" 14'-0" 14'-0" 14'-0" 14'-0" 14'-0"
86'-034"
4'-478"
5'-014"
NOTES:1. ALL PRESSURE BOUNDARY WELDS SHALL BE MADE, EXAMINED, INSPECTED AND TESTED PER APPLICABLE ASME B31.3 REQUIREMENTS. THIS SYSTEM IS DESIGNATED: NORMAL SERVICE 2. FLUID HELIUM DESIGN PRESSURE= 320 PSIG. DESIGN TEMPERATURE = 30 F MIN TO 120 F MAX.
3. CLEAN AND PREPARE COMPONENTS PER PROJECT STATEMENT OF WORK. PIPE SPOOLS AND COMPONENTS SHALL BE PROTECTED FROM DAMAGE AND CONTAMINATION AT ALL TIMES, INCLUDING CAPPING OPEN PIPE ENDS WHEN NOT BEING WORKED AND APPLYING PROTECTIVE COVERS TO FLANGE FACES.
4. REFER TO STATEMENT OF WORK FOR LEAK TESTING DETAILS. PERMITTED LEAK TEST FOR THIS ASSEMBLY IS A PNEUMATIC TEST AT 352 PSIG. 5. DIMENSIONS ARE NOMINAL, FABRICATOR TO VERIFY ALL DIMENSIONS PRIOR TO THE START OF FABRICATION.
6. PRINT THE DRAWING ASSEMBLY NUMBER ON EACH SPOOL SEGMENT PIPE SURFACE USING INDELIBLE INK.
7. TEE AND ELBOW LOCATIONS SET BY AS-BUILT LOCATIONS OF TRENCH AND ASSOCIATED CONNECTIONS ON THE HELIUM STORAGE TANKS.
ISOMETRIC VIEW
6X
4
1'-418"
5
2X1
TYP
REST
RICTIV
E NOT
ICE:
The
se d
esign
s and
dra
wing
s wer
e pr
epar
ed b
y Je
ffers
on S
cienc
e As
socia
tes,
LLC
, her
eina
fter t
he C
ontra
ctor
, und
er C
ontra
ct N
o. D
E-AC
05-06
OR23
177 w
ith th
e De
partm
ent o
f Ene
rgy (
DOE)
. A
ll rig
hts
in th
e de
signs
and
dra
wing
s are
rese
rved
by D
OE o
n be
half
of th
e Un
ited
Stat
es G
overn
ment
and
the
Cont
ract
or a
s pr
ovid
ed in
the
Cont
ract
. You
are
auth
orize
d to
use
thes
e wo
rks
for G
over
nmen
tal p
urpo
ses b
ut it
is n
ot to
be
rele
ased
or d
istri
bute
d to
the
publ
ic. N
EITHE
R TH
E GOV
ERNM
ENT N
OR TH
E CON
TRAC
TOR M
AKES
ANY W
ARRA
NTY,
EXPR
ESS O
R IM
PLIE
D, O
R ASS
UMES
ANY
LIAB
ILIT
Y FO
R THE
USE
OF T
HESE
DESIG
NS O
R DRA
WING
S. (T
his
notic
e in
clud
ing
this
sent
ence
mus
t app
ear o
n an
y cop
ies
of th
ese
desig
ns o
r dra
wing
s.)
DETAIL A
9 316"
1'-31116"
4
1
3
9 316"
REF
1
REF
TYP Approved: 5/2/2017; E-Sign ID : 342112; signed by: Ap. 1: S. Kaminski; Ap. 2: M. Bevins; C.: P. Hansen; D: T. Fuell |
GC PACKAGE 100% FOR REVIEW
QTYREQD
NOMENCLATUREOR DESCRIPTION
QTYREQD NOTESITEM
NO.
PARTS LIST
MATERIALSPECIFICATION
PART ORIDENTIFYING NO.
LCLS-IISTORAGEWARM He
GHe CLEAN LINE INTAKE SPOOL ASSY
79720-0024 -NONE 79720-0012
SEE PARTS LIST
125
J.TSCHIRHART 26AUG2016
1/8 .1.01.005
.50`\.XX \.X \\
.XXX \
REV.
CC
7
7
6
6
5
5
4
4
3
3 2
8
8
D
B
A
D
B
A
12
1
REVISION HISTORY
ZONE REV DESCRIPTION
THIRD ANGLE PROJECTION
MATERIAL
DEBURR & BREAK ALL SHARP EDGES
DO NOT SCALE DRAWING
SHEET OFUSED ON ASSY NO.SCALE
DWG. NO.SIZE
DRAWND
1 1
United States Department of Energy
Newport News Virginia
FINISHMACHINE
SURFACES
UNLESSOTHERWISE
NOTED
DATE
DATE/REVISER
DIM & TOL PER ASME Y14.5 2009. UNLESS OTHERWISE SPECIFIEDDIMENSIONS ARE IN INCHES.TOLERANCES ARE:FRACTIONS DECIMAL ANGLES
\.XX \.X \\
.XXX \
REV.
CC
7
7
6
6
5
5
4
4
3
3 2
8
8
D
B
A
D
B
A
12
1
REVISION HISTORY
ZONE REV DESCRIPTION
THIRD ANGLE PROJECTION
MATERIAL
DEBURR & BREAK ALL SHARP EDGES
DO NOT SCALE DRAWING
SHEET OFUSED ON ASSY NO.SCALE
DWG. NO.SIZE
DRAWND
1 1
United States Department of Energy
Newport News Virginia
FINISHMACHINE
SURFACES
UNLESSOTHERWISE
NOTED
DATE
DATE/REVISER
DIM & TOL PER ASME Y14.5 2009. UNLESS OTHERWISE SPECIFIEDDIMENSIONS ARE IN INCHES.TOLERANCES ARE:FRACTIONS DECIMAL ANGLES
NOTES:1) ALL PRESSURE BOUNDARY WELDS SHALL BE MADE, EXAMINED, INSPECTED AND TESTED PER APPLICABLE ASME B31.3 REQUIREMENTS. THIS SYSTEM IS DESIGNATED: NORMAL SERVICE 2) FLUID HELIUM DESIGN PRESSURE= 320 PSIG. DESIGN TEMPERATURE = 30 F MIN TO 120 F MAX.
3) CLEAN AND PREPARE COMPONENTS PER PROJECT STATEMENT OF WORK. PIPE SPOOLS AND COMPONENTS SHALL BE PROTECTED FROM DAMAGE AND CONTAMINATION AT ALL TIMES, INCLUDING CAPPING OPEN PIPE ENDS WHEN NOT BEING WORKED AND APPLYING PROTECTIVE COVERS TO FLANGE FACES.
4) REFER TO STATEMENT OF WORK FOR LEAK TESTING DETAILS. PERMITTED LEAK TEST FOR THIS ASSEMBLY IS A PNEUMATIC TEST AT 352 PSIG. 5) DIMENSIONS ARE NOMINAL, FABRICATOR TO VERIFY ALL DIMENSIONS PRIOR TO THE START OF FABRICATION.
6) PRINT THE DRAWING ASSEMBLY NUMBER ON EACH SPOOL SEGMENT PIPE SURFACE USING INDELIBLE INK.
2X
7) SEE DRAWING 75600-0691 FOR SLIP-ON FLANGE WELDING DETAILS.
8) FLANGE LOCATION SET BY AS-BUILT LOCATION OF ASSOCIATED CONNECTION ON THE HELIUM STORAGE TANKS.
9) TAG NUMBERS FOR COMPONENTS USED IN CRYOGENIC PLANT #1 SHALL BE LABELED WITH A PREFIX OF "C1", TAG NUMBERS FOR COMPONENTS USED IN CRYOGENIC PLANT #2 SHALL BE LABELED WITH A PREFIX OF "C2". COMPONENTS COMMON TOBOTH CRYOGENIC PLANTS SHALL BE LABELED WITH A PREFIX OF "C".
10)ALL COMPONENTS ON THIS DRAWING ARE COMMON TO BOTH CRYOGENIC PLANTS.
11)TAG NUMBERS THAT ARE TYPICAL TO MORE THAN ONE LOCATION USE X TO INDICATE THE CHARACTER THAT VARIES BY LOCATION. IN THIS APPLICATION, X IS EQUAL TO THE LAST DIGIT IN THE TAG NUMBER OF THE ASSOCIATED GAS HELIUM STORAGE TANK.
9
10
11
491516"
EV11X03 Approved: 5/2/2017; E-Sign ID : 342097; signed by: Ap. 1: S. Kaminski; Ap. 2: M. Bevins; C.: P. Hansen; D: T. Fuell |
DIM & TOL PER ASME Y14.5. UNLESS OTHERWISE SPECIFIEDDIMENSIONS ARE IN INCHES.
FRACTIONS DECIMAL ANGLES
FINISHMACHINE
SURFACES
UNLESSOTHERWISE
NOTED
DATE
TOLERANCES ARE:
LCLS-IISTORAGEWARM He
GHe PURIFIER DISCHARGE HEADER SPOOL ASSY
79720-0027 -NONE 79720-0013
SEE PARTS LIST
125
T. CRAHAN 1 MAR 16
1/16 .1.01.005
.50`
5
1
4
2
6
14'-158" 14'-0" 14'-0" 14'-0" 14'-0" 14'-0"
85'-534"
3'-478"
5'-014"
ISOMETRIC VIEW
6X
REST
RICTIV
E NOT
ICE:
The
se d
esign
s and
dra
wing
s wer
e pre
pare
d by
Jef
fers
on S
cienc
e As
socia
tes,
LLC,
her
eina
fter t
he C
ontra
ctor
, und
er C
ontra
ct No
. DE-
AC05
-06OR
2317
7 with
the
Depa
rtmen
t of E
nerg
y (DO
E). A
ll rig
hts
in th
e de
signs
and d
rawi
ngs
are
rese
rved
by D
OE o
n be
half
of th
e Un
ited
Stat
es G
overn
ment
and
the
Cont
ract
or a
s pr
ovide
d in
the
Cont
ract
. You
are
aut
horiz
ed to
use
thes
e wo
rks
for G
over
nmen
tal pu
rpos
es b
ut it
is n
ot to
be
relea
sed
or d
istri
bute
d to
the
publ
ic. N
EITHE
R TH
E GOV
ERNM
ENT N
OR TH
E CON
TRAC
TOR M
AKES
ANY W
ARRA
NTY,
EXPR
ESS O
R IM
PLIE
D, O
R ASS
UMES
ANY L
IABI
LITY
FOR T
HE US
E OF T
HESE
DESIG
NS O
R DRA
WING
S. (T
his
notic
e in
cludi
ng th
is se
nten
ce m
ust a
ppea
r on
any c
opies
of t
hese
des
igns
or d
rawi
ngs.
)
1'-418"
DETAIL B
B
49 316"
9 316"
5REF1
3
1 REFDETAIL A
DETAIL A
TYP
NOTES:
1) ALL PRESSURE BOUNDARY WELDS SHALL BE MADE, EXAMINED, INSPECTED AND TESTED PER APPLICABLE ASME B31.3 REQUIREMENTS. THIS SYSTEM IS DESIGNATED: NORMAL SERVICE 2) FLUID HELIUM DESIGN PRESSURE= 275 PSIG. DESIGN TEMPERATURE = 30 F MIN TO 120 F MAX.
3) CLEAN AND PREPARE COMPONENTS PER PROJECT STATEMENT OF WORK. PIPE SPOOLS AND COMPONENTS SHALL BE PROTECTED FROM DAMAGE AND CONTAMINATION AT ALL TIMES,INCLUDING CAPPING OPEN PIPE ENDS WHEN NOT BEING WORKED AND APPLYING PROTECTIVE COVERS TO FLANGE FACES.
4) REFER TO STATEMENT OF WORK FOR LEAK TESTING DETAILS. PERMITTED LEAK TEST FOR THIS ASSEMBLY IS A PNEUMATIC TEST AT 303 PSIG.
5) DIMENSIONS ARE NOMINAL, FABRICATOR TO VERIFY ALL DIMENSIONS PRIOR TO THE START OF FABRICATION.
6) PRINT THE DRAWING ASSEMBLY NUMBER ON EACH SPOOL SEGMENT PIPE SURFACE USING INDELIBLE INK.
7) TEE AND ELBOW LOCATIONS SET BY AS-BUILT LOCATION OF TRENCH AND ASSOCIATED CONNECTIONS ON THE HELIUM STORAGE TANKS.
TYP Approved: 5/2/2017; E-Sign ID : 342102; signed by: Ap. 1: S. Kaminski; Ap. 2: M. Bevins; C.: P. Hansen; D: T. Fuell |
GC PACKAGE 100% FOR REVIEW
LCLS-IISTORAGEWARM He
GHe PURIFIER DISCHARGE UPPER SPOOL ASSY
79720-0028 -NONE 79720-0013
SEE PARTS LIST
125
J.TSCHIRHART 26AUG2016
1/8 .1.01.005
.50`\.XX \.X \\
.XXX \
REV.
CC
7
7
6
6
5
5
4
4
3
3 2
8
8
D
B
A
D
B
A
12
1
REVISION HISTORY
ZONE REV DESCRIPTION
THIRD ANGLE PROJECTION
MATERIAL
DEBURR & BREAK ALL SHARP EDGES
DO NOT SCALE DRAWING
SHEET OFUSED ON ASSY NO.SCALE
DWG. NO.SIZE
DRAWND
1 1
United States Department of Energy
Newport News Virginia
FINISHMACHINE
SURFACES
UNLESSOTHERWISE
NOTED
DATE
DATE/REVISER
DIM & TOL PER ASME Y14.5 2009. UNLESS OTHERWISE SPECIFIEDDIMENSIONS ARE IN INCHES.TOLERANCES ARE:FRACTIONS DECIMAL ANGLES
\.XX \.X \\
.XXX \
REV.
CC
7
7
6
6
5
5
4
4
3
3 2
8
8
D
B
A
D
B
A
12
1
REVISION HISTORY
ZONE REV DESCRIPTION
THIRD ANGLE PROJECTION
MATERIAL
DEBURR & BREAK ALL SHARP EDGES
DO NOT SCALE DRAWING
SHEET OFUSED ON ASSY NO.SCALE
DWG. NO.SIZE
DRAWND
1 1
United States Department of Energy
Newport News Virginia
FINISHMACHINE
SURFACES
UNLESSOTHERWISE
NOTED
DATE
DATE/REVISER
DIM & TOL PER ASME Y14.5 2009. UNLESS OTHERWISE SPECIFIEDDIMENSIONS ARE IN INCHES.TOLERANCES ARE:FRACTIONS DECIMAL ANGLES
1) ALL PRESSURE BOUNDARY WELDS SHALL BE MADE, EXAMINED, INSPECTED AND TESTED PER APPLICABLE ASME B31.3 REQUIREMENTS. THIS SYSTEM IS DESIGNATED: NORMAL SERVICE 2) FLUID HELIUM DESIGN PRESSURE= 275 PSIG. DESIGN TEMPERATURE = 30 F MIN TO 120 F MAX.
3) CLEAN AND PREPARE COMPONENTS PER PROJECT STATEMENT PIPE SPOOLS AND COMPONENTS SHALL BE PROTECTED FROM DAMAGE AND CONTAMINATION AT ALL TIMES,INCLUDING CAPPING OPEN PIPE ENDS WHEN NOT BEING WORKED AND APPLYING PROTECTIVE COVERS TO FLANGE FACES.
4) REFER TO STATEMENT OF WORK FOR LEAK TESTING DETAILS. PERMITTED LEAK TEST FOR THIS ASSEMBLY IS A PNEUMATIC TEST AT 303 PSIG.
5) DIMENSIONS ARE NOMINAL, FABRICATOR TO VERIFY ALL DIMENSIONS PRIORTO THE START OF FABRICATION.
6) PRINT THE DRAWING ASSEMBLY NUMBER ON EACH SPOOL SEGMENT PIPE SURFACE USING INDELIBLE INK.
7) SEE DRAWING 75600-0691 FOR SLIP-ON FLANGE WELDING DETAILS.
8) FLANGE LOCATION SET BY AS-BUILT LOCATION OF ASSOCIATED CONNECTION ON THE HELIUM STORAGE TANKS.
9) TAG NUMBERS FOR COMPONENTS USED IN CRYOGENIC PLANT #1 SHALL BE LABELED WITH A PREFIX OF "C1", TAG NUMBERS FOR COMPONENTS USED IN CRYOGENIC PLANT #2 SHALL BE LABELED WITH A PREFIX OF "C2". COMPONENTS COMMON TO BOTH CRYOGENIC PLANTS SHALL BE LABELED WITH A PREFIX OF "C".
10) ALL COMPONENTS ON THIS DRAWING ARE COMMON TO BOTH CRYOGENIC PLANTS.
11) TAG NUMBERS THAT ARE TYPICAL TO MORE THAN ONE LOCATION USE X TO INDICATE THE CHARACTER THAT VARIES BY LOCATION. IN THIS APPLICATION,X IS EQUAL TO THE LAST DIGIT IN THE TAG NUMBER OF THE ASSOCIATED GAS HELIUM STORAGE TANK.
6'-11516"
EV11X02
TYP
1REF Approved: 5/2/2017; E-Sign ID : 342101; signed by: Ap. 1: S. Kaminski; Ap. 2: M. Bevins; C.: P. Hansen; D: T. Fuell |
DIM & TOL PER ASME Y14.5. UNLESS OTHERWISE SPECIFIEDDIMENSIONS ARE IN INCHES.
FRACTIONS DECIMAL ANGLES
FINISHMACHINE
SURFACES
UNLESSOTHERWISE
NOTED
DATE
TOLERANCES ARE:
LCLS-IISTORAGEWARM He
DIRTY LINE PIPE SPOOL - THRU TRENCH
79720-0031 -NONE 79720-0011
SEE PARTS LIST
125
T. CRAHAN 3 MAR 16
1/16 .1.01.005
.50`
1
2
NOTES:
1. ALL PRESSURE BOUNDARY WELDS SHALL BE MADE, EXAMINED, INSPECTED AND TESTED PER APPLICABLE ASME B31.3 REQUIREMENTS. THIS SYSTEM IS DESIGNATED: NORMAL SERVICE 2. FLUID HELIUM DESIGN PRESSURE= 320 PSIG. DESIGN TEMPERATURE = 30 F MIN TO 120 F MAX.
3. CLEAN AND PREPARE COMPONENTS PER PROJECT STATEMENT OF WORK. PIPE SPOOLS AND COMPONENTS SHALL BE PROTECTED FROM DAMAGE AND CONTAMINATION AT ALL TIMES, INCLUDING CAPPING OPEN PIPE ENDS WHEN NOT BEING WORKED AND APPLYING PROTECTIVE COVERS TO FLANGE FACES.
4. REFER TO STATEMENT OF WORK FOR LEAK TESTING DETAILS. PERMITTED LEAK TEST FOR THIS ASSEMBLY IS A PNEUMATIC TEST AT 352 PSIG. 5. DIMENSIONS ARE NOMINAL, FABRICATOR TO VERIFY ALL DIMENSIONS PRIOR TO THE START OF FABRICATION.
6. PRINT THE DRAWING ASSEMBLY NUMBER ON EACH SPOOL SEGMENT PIPE SURFACE USING INDELIBLE INK.
ISOMETRIC VIEW
56'-10 316"
REST
RICTIV
E NOT
ICE:
The
se d
esign
s and
dra
wing
s wer
e pr
epar
ed b
y Je
ffers
on S
cienc
e As
socia
tes,
LLC
, her
eina
fter t
he C
ontra
ctor
, und
er C
ontra
ct N
o. D
E-AC
05-06
OR23
177 w
ith th
e De
partm
ent o
f Ene
rgy (
DOE)
. A
ll rig
hts
in th
e de
signs
and
dra
wing
s are
rese
rved
by D
OE o
n be
half
of th
e Un
ited
Stat
es G
overn
ment
and
the
Cont
ract
or a
s pr
ovid
ed in
the
Cont
ract
. You
are
auth
orize
d to
use
thes
e wo
rks
for G
over
nmen
tal p
urpo
ses b
ut it
is n
ot to
be
rele
ased
or d
istri
bute
d to
the
publ
ic. N
EITHE
R TH
E GOV
ERNM
ENT N
OR TH
E CON
TRAC
TOR M
AKES
ANY W
ARRA
NTY,
EXPR
ESS O
R IM
PLIE
D, O
R ASS
UMES
ANY
LIAB
ILIT
Y FO
R THE
USE
OF T
HESE
DESIG
NS O
R DRA
WING
S. (T
his
notic
e in
clud
ing
this
sent
ence
mus
t app
ear o
n an
y cop
ies
of th
ese
desig
ns o
r dra
wing
s.)
Approved: 5/2/2017; E-Sign ID : 342113; signed by: Ap. 1: S. Kaminski; Ap. 2: M. Bevins; C.: P. Hansen; D: T. Fuell |
DIM & TOL PER ASME Y14.5. UNLESS OTHERWISE SPECIFIEDDIMENSIONS ARE IN INCHES.
FRACTIONS DECIMAL ANGLES
FINISHMACHINE
SURFACES
UNLESSOTHERWISE
NOTED
DATE
TOLERANCES ARE:
LCLS-IISTORAGEWARM He
GHe PURIFIER DISCHARGE PIPE SPOOL - THRU TRENCH
79720-0032 -NONE 79720-0013
SEE PARTS LIST
125
T. CRAHAN 1 MAR 16
1/16 .1.01.005
.50`
58'-9 316"
ISOMETRIC VIEW
1
2
NOTES:
1. ALL PRESSURE BOUNDARY WELDS SHALL BE MADE, EXAMINED, INSPECTED AND TESTED PER APPLICABLE ASME B31.3 REQUIREMENTS. THIS SYSTEM IS DESIGNATED: NORMAL SERVICE 2. FLUID HELIUM DESIGN PRESSURE= 275 PSIG. DESIGN TEMPERATURE = 30 F MIN TO 120 F MAX.
3. CLEAN AND PREPARE COMPONENTS PER PROJECT STATEMENT OF WORK. PIPE SPOOLS AND COMPONENTS SHALL BE PROTECTED FROM DAMAGE AND CONTAMINATION AT ALL TIMES, INCLUDING CAPPING OPEN PIPE ENDS WHEN NOT BEING WORKED AND APPLYING PROTECTIVE COVERS TO FLANGE FACES.
4. REFER TO STATEMENT OF WORK FOR LEAK TESTING DETAILS. PERMITTED LEAK TEST FOR THIS ASSEMBLY IS A PNEUMATIC TEST AT 303 PSIG. 5. DIMENSIONS ARE NOMINAL, FABRICATOR TO VERIFY ALL DIMENSIONS PRIOR TO THE START OF FABRICATION.
6. PRINT THE DRAWING ASSEMBLY NUMBER ON EACH SPOOL SEGMENT PIPE SURFACE USING INDELIBLE INK.
REST
RICTIV
E NOT
ICE:
The
se d
esign
s and
dra
wing
s wer
e pr
epar
ed b
y Je
ffers
on S
cienc
e As
socia
tes,
LLC
, her
eina
fter t
he C
ontra
ctor
, und
er C
ontra
ct N
o. D
E-AC
05-06
OR23
177 w
ith th
e De
partm
ent o
f Ene
rgy (
DOE)
. A
ll rig
hts
in th
e de
signs
and
dra
wing
s are
rese
rved
by D
OE o
n be
half
of th
e Un
ited
Stat
es G
overn
ment
and
the
Cont
ract
or a
s pr
ovid
ed in
the
Cont
ract
. You
are
auth
orize
d to
use
thes
e wo
rks
for G
over
nmen
tal p
urpo
ses b
ut it
is n
ot to
be
rele
ased
or d
istri
bute
d to
the
publ
ic. N
EITHE
R TH
E GOV
ERNM
ENT N
OR TH
E CON
TRAC
TOR M
AKES
ANY W
ARRA
NTY,
EXPR
ESS O
R IM
PLIE
D, O
R ASS
UMES
ANY
LIAB
ILIT
Y FO
R THE
USE
OF T
HESE
DESIG
NS O
R DRA
WING
S. (T
his
notic
e in
clud
ing
this
sent
ence
mus
t app
ear o
n an
y cop
ies
of th
ese
desig
ns o
r dra
wing
s.)
Approved: 5/2/2017; E-Sign ID : 342111; signed by: Ap. 1: S. Kaminski; Ap. 2: M. Bevins; C.: P. Hansen; D: T. Fuell |
GC PACKAGE 100% FOR REVIEW
\.XX \.X \\
.XXX \
REV.
CC
7
7
6
6
5
5
4
4
3
3 2
8
8
D
B
A
D
B
A
12
1
REVISION HISTORY
ZONE REV DESCRIPTION DATE APPROVED
THIRD ANGLE PROJECTION
MATERIAL
DEBURR & BREAK ALL SHARP EDGES
DO NOT SCALE DRAWING
SHEET OFUSED ON ASSY NO.SCALE
DWG. NO.SIZE
DRAWND
1 1
United States Department of Energy
Newport News Virginia
DIM & TOL PER ASME Y14.5. UNLESS OTHERWISE SPECIFIEDDIMENSIONS ARE IN INCHES.
FRACTIONS DECIMAL ANGLES
FINISHMACHINE
SURFACES
UNLESSOTHERWISE
NOTED
DATE
TOLERANCES ARE:
LCLS-IISTORAGEWARM He
GHe CLEAN LINE PIPE SPOOL - THRU TRENCH TO DISTRIBUTION
1. ALL PRESSURE BOUNDARY WELDS SHALL BE MADE, EXAMINED, INSPECTED AND TESTED PER APPLICABLE ASME B31.3 REQUIREMENTS. THIS SYSTEM IS DESIGNATED: NORMAL SERVICE 2. FLUID HELIUM DESIGN PRESSURE= 320 PSIG. DESIGN TEMPERATURE = 30 F MIN TO 120 F MAX.
3. CLEAN AND PREPARE COMPONENTS PER PROJECT STATEMENT OF WORK. PIPE SPOOLS AND COMPONENTS SHALL BE PROTECTED FROM DAMAGE AND CONTAMINATION AT ALL TIMES, INCLUDING CAPPING OPEN PIPE ENDS WHEN NOT BEING WORKED AND APPLYING PROTECTIVE COVERS TO FLANGE FACES.
4. REFER TO STATEMENT OF WORK FOR LEAK TESTING DETAILS. PERMITTED LEAK TEST FOR THIS ASSEMBLY IS A PNEUMATIC TEST AT 352 PSIG. 5. DIMENSIONS ARE NOMINAL, FABRICATOR TO VERIFY ALL DIMENSIONS PRIOR TO THE START OF FABRICATION.
6. PRINT THE DRAWING ASSEMBLY NUMBER ON EACH SPOOL SEGMENT PIPE SURFACE USING INDELIBLE INK.
Approved: 5/2/2017; E-Sign ID : 342099; signed by: Ap. 1: S. Kaminski; Ap. 2: M. Bevins; C.: P. Hansen; D: T. Fuell |