TEST EQUIPMENT equipment 100 % owned by qatro In most test
equipment there are several units, allowing us to provide similar
services in different sites simultaneous
© QATRO-ELEC-ISEI S.L. QE\DpC\PR&PU\P\02-2 FECHA 021106 REV.
011114 HOJA 1 DE 19 QATRO-ELEC-ingeniería y servicios eléctricos
industriales S.L. : inscrita en el Registro Mercantil de A Coruña,
Tomo 3.139 del Archivo, Sección General, al folio 55, hoja número
C-39.770, inscripción 1ª, C.I.F. B70077896
ALINEAR EL TEXTO A LA IZQUIERDA ELECTRICITY SPECIAL FOR … MAIN
FEATURES PRIMARY PRIMARY INJECTIONS OMICRON CPC100 + CP SB1
EE-P01
♦ Injection of high value voltage and current for the primary
test (power circuit) in all types of electrical equipment :
→ Power transformers → Current transformers → Voltage
transformers → Resistances → Electrical protection equipment:
Electromechanical → LV and HV circuit breakers → LV and HV
electric motors → …
CPC100 : ♦ 800 Aac ♦ 400 Adc ♦ 2.000 Vac ♦ 15 – 400 Hz CP SB1
(caja de conmutación) : ♦ 300 Vac ♦ 6 Adc
DIELECTRIC STRENGTH (HIPOT) BAUR P&M VIOLA 411+047
EE-P02
♦ Injection of high value voltages for dielectric strength test
(HIPOT : high potential) of any dry insulation, with both DC and AC
voltages of very low frequency
♦ 40 KVac (0,01 ÷ 0,1 Hz) ♦ ± 60 KVdc (0 Hz)
DIELECTRIC STRENGTH (HIPOT) BAUR P&M FRIDA 411+046
EE-P03
♦ Injection voltages high value for dielectric strength test
(HIPOT: high potential) of any type of cable jacket and any dry
insulation switchgear, both voltage (DC) and alternating voltage of
very low frequency (VLF)
♦ 23 KVac (0,01 ÷ 0,1 Hz) ♦ ± 30 KVdc (0 Hz)
HV CIRCUIT BREAKERS EUROSMC PME-500-TR + PME-TCE + PME-ATK
EE-P04
♦ Test of high voltage circuit breakers : → Closing and opening
times → Pole contact resistance → Synchronism between poles → Pole
shift (Course, speed and acceleration) → Peak currents of opening
and closing coils → Actuating times of closing and opening coils →
Graph of closing and opening coils consumption
♦ 100 – 2.000 ms ♦ 0 – 50 Adc ♦ 100,0 μΩ – 1,000 Ω ♦ Course ♦
Speed ♦ Acceleration
-
TEST EQUIPMENT equipment 100 % owned by qatro In most test
equipment there are several units, allowing us to provide similar
services in different sites simultaneous
© QATRO-ELEC-ISEI S.L. QE\DpC\PR&PU\P\02-2 FECHA 021106 REV.
011114 HOJA 2 DE 19 QATRO-ELEC-ingeniería y servicios eléctricos
industriales S.L. : inscrita en el Registro Mercantil de A Coruña,
Tomo 3.139 del Archivo, Sección General, al folio 55, hoja número
C-39.770, inscripción 1ª, C.I.F. B70077896
ELECTRICITY SPECIAL FOR … MAIN FEATURES LV ELECTRICAL
INSTALLATIONS (S/ RBT 05) HT ITALIA ALLTEST AMPROBE I EE-P05
♦ Test of LV electrical installations, in accordance with
complementary technical instructions RBT 05 "checks and
inspections" (regulation of LV Spanish) :
→ Insulation resistance → Dielectric strength → Voltage drop and
continuity of protective conductors (PE) → Leakage current in
energy sources → Discharge time in socket power plugs → Discharge
time in internal components
♦ Ra (MΩ) (500 Vdc) ♦ RD (HIPOT) (1,000 – 4,000 Vac) ♦ ∆U /
continuity (6-12 Vac / 10-25 Aac)
CAPACITANCE / DISSIPATION FACTOR (TAN DELTA) OMICRON CP TD1
EE-P06
♦ Test for the isolation status in transformers, generators, …
according IEEE 62 (C51.152) and IEC 60076-1 and -3 ♦ Testing is
performed at variable frequencies to better diagnose signs of
ageing in insulation ♦ Tests :
→ Capacitance → Dissipation factor (tan δ) → Power factor cos φ
→ Power looses → Outgoing (effective power, apparent power,
reactive power) → Impedance (absolute value, phase, inductance,
resistance, quality)
♦ 12 KVac ♦ 5 Aac ♦ 8 Aac ♦ 1pF – 3 µF Tan δ : ♦ 0 – 10 %
(capacitive) ♦ 0 – 100 % Cos φ : ♦ 0 – 10 % (capacitive) ♦ 0 – 100
%
FREQUENCY RESPONSE MEGGER FRAX 101 EE-P07
♦ Detection of potential mechanical and electrical problems that
other methods are unable to detect :
→ Winding deformations and displacements → Shorted turns and
open windings → Loosened clamping structures → Broken clamping
structures → Core connection problems → Partial winding collapse →
Faulty core grounds → Core movements → Hoop buckling
♦ 0,1 Hz – 25 MHz ♦ 32.000 points ♦ 64 s – 37 s (20 Hz – 2 MHz)
♦ Points Spacing: Log., linear or both
METAL OXIDE SURGE ARRESTER TEST ISA SCAR 10 EE-P08
♦ On-line diagnostic indicator of metal oxide surge arrester
efficiency IEC 60099-5 A1 ED1-0 ♦ Third harmonic analysis of
leakage current with compensation
♦ Range of total current rms and peak measures: 1.999 mA, for
currents less than 1 mA, or 19.99 mA for higher currents. ♦ Third
harmonic range: 199.9 µA for currents less than 1 mA, or 1999 µA
for higher currents ♦ Response of the third harmonic filter:
. < - 60 dB at 50 Hz;
. 0 dB at 150 Hz;
. < - 20 dB at 250 Hz and higher frequencies
-
TEST EQUIPMENT equipment 100 % owned by qatro In most test
equipment there are several units, allowing us to provide similar
services in different sites simultaneous
© QATRO-ELEC-ISEI S.L. QE\DpC\PR&PU\P\02-2 FECHA 021106 REV.
011114 HOJA 3 DE 19 QATRO-ELEC-ingeniería y servicios eléctricos
industriales S.L. : inscrita en el Registro Mercantil de A Coruña,
Tomo 3.139 del Archivo, Sección General, al folio 55, hoja número
C-39.770, inscripción 1ª, C.I.F. B70077896
ELECTRICITY SPECIAL FOR … MAIN FEATURES HV CIRCUIT BRAKERS
MEGGER TM1800 CG-19040 TM1800 + XB-51020 + XB-39130 + XB-39140
EE-P09
♦ Dual Ground Circuit Breaker Analyzer:
→ Timing measurements → Motion measurements → Coil currents →
Dynamic resistance measurement (DRM) → Vibration analysis →
DualGround™ testing
♦ 100 – 2.000 ms ♦ 0 – 100 Adc ♦ 500μΩ - 10 kΩ
DIELECTRIC RESPONSE ANALYSIS AND MOISTURE IN OIL-PAPER
DIELECTRICS FDS-PDC OMICRON DIRANA EE-P10
♦ Water analysis of oil-paper insulation ♦ Capacitance and
dissipation factor measurement on power transformers ♦ Dissipation
factor measurement and determination of ageing on bushings ♦
Diagnosis of generator, motor and cable insulation, as well as
instrument transformers
→ Capacitance 10 pF to 100 μF → Accuracy 0,5 % + 1 pF ♦ PDC →
Range, resolution 20 mA, 0,1 pA → Input resistance 10 kW → Accuracy
0,5 % ± 1 pA ♦ FDS → Voltage 200 Vpeak → Current 50 mApeak
INSULATION / CAPACITANCE / DISSIPATION FACTOR (TAN DELTA) DOBLE
M4100 + TTR EE-P11
♦ 12 kV Power Factor/Tan-Delta capacitance testing to assess
insulation condition & dielectric loss ♦ High stress and high
accuracy 10 kV TTR with the dobleTTR Capacitor ♦ Winding Leakage
Reactance testing with the M4110 to detect winding deformation or
damage ♦ 10 kV Single-Phase Excitation Current testing to detect
degraded turn-to-turn insulation damage and magnetic circuit
anomalies
♦ 12 kVac ♦ 3 kVac ♦ 16 A max at 110 V ♦ 10 A max at 220 V ♦ 0
to 100 μF ♦ Resolution: 0.01 pF ♦ % Tan δ: 0 to ± 999,99 %
LEAKAGE REACTANCE DOBLE M4110 EE-P12
♦ Winding Leakage Reactance testing ♦ Winding deformation or
damage diagnoses
♦ 0,1to 700 Ω ♦ 250 μH to 1,8 H ♦ 120 or 240 V at 10 A (50/60
Hz)
SWEEP FREQUENCY RESPONSE ANALYZER (SFRA) DOBLE M5400 EE-P13
♦ Sweep frequency response analyzer ♦ Analyze the winding
relationship inside a transformer ♦ Detect mechanical failure or
movement of windings.
♦ Frequency response measurement : from 10 Hz to 25 MHz
♦ 20 Vpp at 50Ω
-
TEST EQUIPMENT equipment 100 % owned by qatro In most test
equipment there are several units, allowing us to provide similar
services in different sites simultaneous
© QATRO-ELEC-ISEI S.L. QE\DpC\PR&PU\P\02-2 FECHA 021106 REV.
011114 HOJA 4 DE 19 QATRO-ELEC-ingeniería y servicios eléctricos
industriales S.L. : inscrita en el Registro Mercantil de A Coruña,
Tomo 3.139 del Archivo, Sección General, al folio 55, hoja número
C-39.770, inscripción 1ª, C.I.F. B70077896
ELECTRICITY SPECIAL FOR … MAIN FEATURES OLTC ANALYZER &
WINDING OHMMETER DV POWER RMO100TT EE-P14
♦ On-load tap changer dynamic resistance measurement. ♦ Winding
resistance measurement.
♦ Static resistance : → 5 mA – 100 A DC → up to 60 V DC → 0,1 μΩ
- 2 kΩ → ± (0,1 % rdg + 0,1 % F.S.) ♦ Dynamic resistance OLTC : →
Frequency range: 0,1 ms
MICRO-OHMÍMETER MEGGER MJÖLNER 600 EE-P15
♦ Contact resistance measurement test ♦ DualGround™ testing
♦ Outputs: → 5 – 600 Adc → Max. V : 5,25 V to 600 A ♦ Range
measurement : → 0 – 999.9 mΩ ♦Accuracy: → 0,1 µΩ for R< 1,0 mΩ →
1 µΩ for R< 10 mΩ → 10 µΩ for R< 100 mΩ → 100 µΩ for R<
1000 mΩ
-
TEST EQUIPMENT equipment 100 % owned by qatro In most test
equipment there are several units, allowing us to provide similar
services in different sites simultaneous
© QATRO-ELEC-ISEI S.L. QE\DpC\PR&PU\P\02-2 FECHA 021106 REV.
011114 HOJA 5 DE 19 QATRO-ELEC-ingeniería y servicios eléctricos
industriales S.L. : inscrita en el Registro Mercantil de A Coruña,
Tomo 3.139 del Archivo, Sección General, al folio 55, hoja número
C-39.770, inscripción 1ª, C.I.F. B70077896
ELECTRICITY SPECIALS FOR … MAIN FEATURES SECONDARIES SECONDARY
INJECTIONS OMICRON CMC256 PLUS EE-S01
♦ Injection of low value voltage and current for the secondary
test (electrical protection equipment and
control-command-supervision circuits) of all types of electrical
equipment :
→ Electrical protection equipment: Electromechanical Analogue
Digital
→ Measuring transducers → HV circuit breakers → …
♦ 2 x (3 x 0 - 12,5 Aac) ♦ 2 x (1 x 0 - 37,5 Aac) ♦ 2 x (1 x 0 -
± 17,5 Adc) ♦ 2 x (1 x 0 - ± 12,5 Adc) ♦ 1 x (3 x 0 - 25 Aac) ♦ 1 x
(1 x 0 - 75 Aac) ♦ 1 x (1 x 0 - ± 35 Adc) ♦ 1 x (1 x 0 - ± 25 Adc)
♦ 4 x 0 - 300 Vac ♦ 1 x 0 - 600 Vac ♦ 4 x 0 - ± 300 Vdc
SECONDARY INJECTIONS OMICRON CMC356 EE-S02
♦ Injection of low value voltage and current for the secondary
test (protection equipment and control-command-supervision
circuits) of all types of electrical equipment :
→ Electrical protection equipment: Electromechanical Analogue
Digital
→ Measuring transducers → HV circuit breakers → …
♦ 6 x 0 - 32 Aac ♦ 3 x 0 - 64 Aac ♦ 1 x 0 - 128 Aac ♦ 1 x 0 - ±
180 Adc ♦ 4 x 0 - 300 Vac ♦ 1 x 0 - 600 Vac ♦ 4 x 0 - ± 300 Vdc
LOG – ANALYSIS OF ELECTRIC NETWORKS (AC AND FAST VARIATION)
GOSSEN / METRAWATT MAVOWATT 70 + 3 x TR-2510A (Z817A) + 3 x
TR-2500A (Z817B) EE-S03
♦ Log – analysis of very high frequency (up to 1 μs) transient
phenomena, assessment of incidents and obtaining of specific
distortion and asymmetry values of the network being tested
♦ 4 U channels (1 – 600 Vac-dc) ♦ 4 I channels (0.1 – 6,000
Aac-dc) ♦ Fundamental wave 45-65 Hz and 15-20 Hz ♦ Network quality
in accordance with UNE-EN 50160 / IEC 61000-4-30 Class A / IEEE
1159 ♦ Sensor clamp TR-2510A :
1-10 AacRMS 40-5,000 Hz
♦ Sensor clamp TR-2500A : 10-500 AacRMS 40-5,000 Hz
LOG – ANALYSIS OF ELECTRIC NETWORKS (AC AND FAST VARIATION)
GOSSEN / METRAWATT MAVOWATT 30 + 3 x TR-2510A (Z817A) EE-S04
♦ Log – analysis of very high frequency (up to 1 μs) transient
phenomena, assessment of incidents and obtaining of specific
distortion and asymmetry values of the network being tested
♦ 4 U channels (1 – 600 Vac-dc) ♦ 4 I channels (0.1 – 6,000
Aac-dc) ♦ Fundamental wave 45-65 Hz and 15-20 Hz ♦ Network quality
in accordance with UNE-EN 50160 / IEC 61000-4-30 Class A / IEEE
1159 ♦ Similar to GOSSEN / METRAWATT MAVOWATT 70 but with a few
less features ♦ Sensor clamp TR-2510A :
1-10 AacRMS 40-5,000 Hz
THERMOGRAPHIC INFRARED CAMERA FLIR SYSTEMS T250 EE-S05
♦ Thermography specialised in preventive maintenance as an
powerful tool of choice for searching for hot spots in electrical
installations and faulty equipment ♦ Suitable for inspection of
high voltage overhead power lines (76 mm telephoto lens)
♦ From – 20 °C to 350 °C ♦ Accuracy : ± 2 °C ♦ Lens of 24,6 / 76
mm ♦ Visual field of 25 º / 6 º ♦ 240 x 180 pixels
-
TEST EQUIPMENT equipment 100 % owned by qatro In most test
equipment there are several units, allowing us to provide similar
services in different sites simultaneous
© QATRO-ELEC-ISEI S.L. QE\DpC\PR&PU\P\02-2 FECHA 021106 REV.
011114 HOJA 6 DE 19 QATRO-ELEC-ingeniería y servicios eléctricos
industriales S.L. : inscrita en el Registro Mercantil de A Coruña,
Tomo 3.139 del Archivo, Sección General, al folio 55, hoja número
C-39.770, inscripción 1ª, C.I.F. B70077896
ELECTRICITY SPECIALS FOR … MAIN FEATURES SECONDARIES
THERMOGRAPHIC INFRARED CAMERA FLIR SYSTEMS T420 EE-S06
♦ Thermography specialised in preventive maintenance as an
powerful tool of choice for searching for hot spots in electrical
installations and faulty equipment ♦ Suitable for inspection of
high voltage overhead power lines (76 mm telephoto lens)
♦ Lens of 24,6 / 76 mm ♦ Visual field of 25 º / 6 º ♦ From – 20
°C to + 650 °C ♦ Accuracy : ± 2 °C ♦ 320 x 240 pixels
RECORD - ANALYSIS AC NETWORKS MEMORY HICORDER HIOKI MR8847-01 +
8966 + L9198 EE-S07
♦ Register - analysis of transients very high frequency (up to
20 samples / s), evaluation of incidents and obtaining specific
values of distortion and asymmetry of the network under test
♦ 64 M-words ♦ 16 channels ♦ Accuracy 50 μV ♦ 100 mV f.s. – 400
V f.s. ♦ Frequency range 133 mHz – 8 MHz
-
TEST EQUIPMENT equipment 100 % owned by qatro In most test
equipment there are several units, allowing us to provide similar
services in different sites simultaneous
© QATRO-ELEC-ISEI S.L. QE\DpC\PR&PU\P\02-2 FECHA 021106 REV.
011114 HOJA 7 DE 19 QATRO-ELEC-ingeniería y servicios eléctricos
industriales S.L. : inscrita en el Registro Mercantil de A Coruña,
Tomo 3.139 del Archivo, Sección General, al folio 55, hoja número
C-39.770, inscripción 1ª, C.I.F. B70077896
ELECTRICITY BASIC FOR … MAIN FEATURES INSULATION RESISTANCE +
... MEGGER MIT 1020-2
♦ Comprehensive test of the LV and HV dry insulation, automatic
test of:
→ Insulation resistance (IR) in mode: Interruption Burn Alarm
threshold
→ Polarisation index (PI) → Dielectric absorption ratio (DAR) →
Step voltage (SV) → Dielectric discharge (DD)
♦ From 50 Vdc to 1 KVdc in 10 V step ♦ From 1 KVdc to 10 KVdc in
25 V step ♦ Measurements over 100 GΩ (three wires)
INSULATION RESISTANCE + ... MEGGER MIT 1025
♦ Comprehensive test of the LV and HV dry insulation, automatic
test of:
→ Insulation resistance (IR) in mode: Interruption Burn
→ Polarisation index (PI) → Dielectric absorption ratio (DAR) →
Step voltage (SV) → Dielectric discharge (DD) → Ramp voltage
test
♦ From 50 Vdc to 1 KVdc in 10 V step ♦ From 1 KVdc to 10 KVdc in
25 V step ♦ Measurements over 100 GΩ (three wires)
INSULATION RESISTANCE GOSSEN / METRAWATT METRISO 5000A
♦ Manual test of insulation resistance (LV and HV dry
insulation)
♦ 100 – 5,000 Vdc ♦ Measurements over 100 GΩ (three wires)
INSULATION RESISTANCE E. KAINOS 4104 IN
♦ Manual test of insulation resistance (LV and HV dry
insulation)
♦ 1,000 – 10,000 Vdc ♦ Measurements over 100 GΩ (three
wires)
INSULATION RESISTANCE GOSSEN / METRAWATT METRISO C
♦ Manual test of insulation resistance (LV dry insulation)
♦ 50 – 1,000 Vdc
-
TEST EQUIPMENT equipment 100 % owned by qatro In most test
equipment there are several units, allowing us to provide similar
services in different sites simultaneous
© QATRO-ELEC-ISEI S.L. QE\DpC\PR&PU\P\02-2 FECHA 021106 REV.
011114 HOJA 8 DE 19 QATRO-ELEC-ingeniería y servicios eléctricos
industriales S.L. : inscrita en el Registro Mercantil de A Coruña,
Tomo 3.139 del Archivo, Sección General, al folio 55, hoja número
C-39.770, inscripción 1ª, C.I.F. B70077896
ELECTRICITY BASIC FOR … MAIN FEATURES PHASE ANGLES EUROSMC
PME-20-CH
♦ Phase angle (U-U / U-I / I-I), frequency, power factor (cos φ)
and for use as synchroscope measurements
♦ 0.2 ÷ 500 Vac ♦ 0.1 ÷ 25 Aac ♦ 40 ÷ 500 Hz
PHASE ANGLES E. KAINOS KAINOPHI
♦ Phase angle (UU / UI) and power factor (cosφ) measurement
♦ 0.5 ÷ 400 Vac ♦ 0.2 ÷ 5 Aac ♦ 40 ÷ 60 Hz
PHASE ANGLES, MULTIMETER AND ANALYSIS OF ELECTRIC NETWORKS
ARBITER SYSTEMS + AEMC 928A + MN352
♦ Phase angle measurement (U-U / U-I / I-I) ♦ Power factor (cos
φ) measurement ♦ Frequency measurement ♦ Active and reactive power
/ energy measurement ♦ Harmonics U / I and flicker by CEI
61000-4-15 ♦ Waveform display (U / I)
♦ 0 ÷ 360 ° o ± 180 ° ♦ ± 1.0000 pf ♦ 1 ÷ 660 Aac ♦ 0.01 ÷ 1.2
Aac ♦ 50 – 60 Hz / ± 5 Hz ♦ 0 a 99,999 MVA o MVAh ± 99,999 MVAR o
MVARh ± 99,999 MW o MWh ♦ From 2nd to 50nd harmonic
-
TEST EQUIPMENT equipment 100 % owned by qatro In most test
equipment there are several units, allowing us to provide similar
services in different sites simultaneous
© QATRO-ELEC-ISEI S.L. QE\DpC\PR&PU\P\02-2 FECHA 021106 REV.
011114 HOJA 9 DE 19 QATRO-ELEC-ingeniería y servicios eléctricos
industriales S.L. : inscrita en el Registro Mercantil de A Coruña,
Tomo 3.139 del Archivo, Sección General, al folio 55, hoja número
C-39.770, inscripción 1ª, C.I.F. B70077896
INSTRUMENTATIÓN ESPECIAL FOR … MAIN FEATURES PRIMARY
MEASUREMENTS – PRIMARY/SECONDARY INJECTIONS BEAMEX MC5 + PGXH + EXT
IE-P01
♦ Calibration / multifunction simulation, for field (on-site),
of instruments:
→ Generation / measurement of pressure → Simulation /
measurement of resistance temperature (RTD) → Simulation /
measurement of resistance → Simulation / measurement of
thermocouple (TC) → Generation / measurement of current →
Generation / measurement of voltage → Generation / measurement of
low voltage → Generation / measurement of frequency → Generation /
counter / of pulses → Detection of contact state (pressure
switches, thermostats, ...) → Customisation of PRT temperature
sensors
♦ Internal + external pressure modules ♦ Communication with
HART® protocol instruments
MEASUREMENTS – PRIMARY/SECONDARY INJECTIONS SCANDURA B-20 \ IS
ATEX + GH1H + INERIS 03 ATEX IE-P02
♦ Calibration / multifunction simulation, for field (on-site) of
ATEX zones, of instruments:
→ Generation / measurement of pressure → Simulation /
measurement of resistance temperature (RTD) → Simulation /
measurement of resistance → Simulation / measurement of
thermocouple (TC) → Generation / measurement of current →
Generation / measurement of voltage → Generation / measurement of
low voltage → Measurement of frequency
♦ Internal + external pressure modules
HEATING AND COOLING FURNACE ISOTECH FAST-CAL LOW IE-P03
♦ Calibration / check, for (on-site), temperature
instruments:
→ Resistance temperatures (RTD) → Thermocouples
♦ From –35 °C to 140 °C ♦ Standard reference probe
-
TEST EQUIPMENT equipment 100 % owned by qatro In most test
equipment there are several units, allowing us to provide similar
services in different sites simultaneous
© QATRO-ELEC-ISEI S.L. QE\DpC\PR&PU\P\02-2 FECHA 021106 REV.
011114 HOJA 10 DE 19 QATRO-ELEC-ingeniería y servicios eléctricos
industriales S.L. : inscrita en el Registro Mercantil de A Coruña,
Tomo 3.139 del Archivo, Sección General, al folio 55, hoja número
C-39.770, inscripción 1ª, C.I.F. B70077896
INSTRUMENTATIÓN ESPECIAL FOR … MAIN FEATURES HEATING FURNACE
ISOTECH FAST-CAL HIGH IE-P04
♦ Calibration / check, for (on-site), temperature
instruments:
→ Resistance temperatures (RTD) → Thermocouples
♦ From +35 ºC to + 650 ºC ♦ Standard reference probe
HEATING FURNACE ISOTECH PEGASUS IE-P05
♦ Calibration / check, for (on-site), temperature
instruments:
→ Resistance temperatures (RTD) → Thermocouples
♦ From +150 ºC to + 1,200 ºC ♦ Standard reference probe
MEASUREMENTS – PRIMARY/SECONDARY INJECTIONS BEAMEX MC6 + EXT +
PGXH + PGM + PGV IE-P06
♦ Calibration / multifunction simulation, for field (on-site),
of instruments:
→ Generation / measurement of pressure → Simulation /
measurement of resistance temperature (RTD) → Simulation /
measurement of resistance → Simulation / measurement of
thermocouple (TC) → Generation / measurement of current →
Generation / measurement of voltage → Generation / measurement of
low voltage → Generation / measurement of frequency → Generation /
counter / of pulses → Detection of contact state (pressure
switches, thermostats, ...) → Customisation of PRT temperature
sensors → Internal power supply 24 Vdc (low impedance, HART
impedance or FF / PA impedance)
♦ Internal + external pressure modules ♦ Communication with
HART® protocol instruments ♦ Communication with FIELDBUS H1
protocol instruments
-
TEST EQUIPMENT equipment 100 % owned by qatro In most test
equipment there are several units, allowing us to provide similar
services in different sites simultaneous
© QATRO-ELEC-ISEI S.L. QE\DpC\PR&PU\P\02-2 FECHA 021106 REV.
011114 HOJA 11 DE 19 QATRO-ELEC-ingeniería y servicios eléctricos
industriales S.L. : inscrita en el Registro Mercantil de A Coruña,
Tomo 3.139 del Archivo, Sección General, al folio 55, hoja número
C-39.770, inscripción 1ª, C.I.F. B70077896
INSTRUMENTATIÓN ESPECIALS FOR … MAIN FEATURES SECONDARY
REGISTRATION - ANALYSIS OF PROCESS SIGNALS (DC AND SLOW VARIATION)
GRAPHTEC MIDILOGGER GL450 IE-S01
♦ Log – analysis of process variables transitory phenomena (DC
and slow variation) and obtaining of specific values for the
instruments being tested
♦ 10 channels (U/I) ♦ Signals:
20-50-100-200-500 mVdc 1-2-5-10-20-50 Vdc / 4-20 mAdc
♦ Sampling: 100-200-500 ms 1-2-3-4-5-10-20-30 s 1-2-5-10-20-30 m
1 h
-
TEST EQUIPMENT equipment 100 % owned by qatro In most test
equipment there are several units, allowing us to provide similar
services in different sites simultaneous
© QATRO-ELEC-ISEI S.L. QE\DpC\PR&PU\P\02-2 FECHA 021106 REV.
011114 HOJA 12 DE 19 QATRO-ELEC-ingeniería y servicios eléctricos
industriales S.L. : inscrita en el Registro Mercantil de A Coruña,
Tomo 3.139 del Archivo, Sección General, al folio 55, hoja número
C-39.770, inscripción 1ª, C.I.F. B70077896
DE INSTRUMENTATIÓN BÁSICS FOR … MAIN FEATURES HART PROTOCOL
COMMUNICATOR MERIAM MC4150X ATEX
♦ Communication with instruments with HART protocol instruments
for field ("in situ") ATEX zones, for configuration, commissioning
and maintenance
♦
HART PROTOCOL COMMUNICATOR EMERSON 475 ATEX
♦ Communication with instruments with HART protocol instruments
for field ("in situ") ATEX zones, for configuration, commissioning
and maintenance
♦
GENERATION - MEASURING OF CURRENT GOMETRICS TINYCAL T220
♦ Calibration / simulation, for field (on-site), of
instruments:
→ Generation / measurement of current
♦ Input / output: 0 to 24 mAdc
SIMULATION – MEASUREMENT OF RESISTANCE / RESISTANCE TEMPERATURE
GOMETRICS TINYCAL T240
♦ Calibration / simulation, for field (on-site), of
instruments:
→ Simulation / measurement of resistance temperature (RTD) →
Simulation / measurement of resistance
♦ Input / output: resistance and pt100
GENERATION – MEASUREMENT OF THERMOCOUPLES GOMETRICS TINYCAL
T250
♦ Calibration / simulation, for field (on-site), of
instruments:
→ Generation / measurement of thermocouple (TC)
♦ Input / output: thermocouple J, K, T, R, S and E
-
TEST EQUIPMENT equipment 100 % owned by qatro In most test
equipment there are several units, allowing us to provide similar
services in different sites simultaneous
© QATRO-ELEC-ISEI S.L. QE\DpC\PR&PU\P\02-2 FECHA 021106 REV.
011114 HOJA 13 DE 19 QATRO-ELEC-ingeniería y servicios eléctricos
industriales S.L. : inscrita en el Registro Mercantil de A Coruña,
Tomo 3.139 del Archivo, Sección General, al folio 55, hoja número
C-39.770, inscripción 1ª, C.I.F. B70077896
COMMNON ELECTRICITY + INSTRUMENTATIÓN FOR … MAIN FEATURES
MULTÍMETRO DIGITAL GOSSEN / METRAWATT METRAHIT TECH
♦ Medidas eléctricas ♦ Corriente continua : resolución 0,1 µA ♦
CAT III 1000 V y CAT IV 600 V
DIGITAL MULTIMETER GOSSEN / METRAWATT METRAHIT PRO
♦ Multifunction multimeter ♦
DIGITAL MULTIMETER + CLAMP GOSSEN / METRAWATT METRAHIT BASE +
CLAMP (IN: A / OUT: V)
♦ Multifunction multimeter ♦
DIGITAL MULTIMETER GOSSEN / METRAWATT METRAHIT 16S
♦ Multifunction multimeter ♦
DIGITAL MULTIMETER MASTECH MY60
♦ Multifunction multimeter ♦ Ucc : 200 mV / 2-20-200-1.000 V ♦
Uca: 200 mV / 2-20-200-700 V ♦ Icc: 20-200 μA / 2-20-200 mA / 2-10
A ♦ Ica: 200 μA / 2-20-200 mA / 2-10 A ♦ Rcc : 200 Ω / 2-20-200 KΩ
/ 2-20-200 MΩ ♦ Continuidad con señal acústica ♦ Prueba de diodos y
transistores
-
TEST EQUIPMENT equipment 100 % owned by qatro In most test
equipment there are several units, allowing us to provide similar
services in different sites simultaneous
© QATRO-ELEC-ISEI S.L. QE\DpC\PR&PU\P\02-2 FECHA 021106 REV.
011114 HOJA 14 DE 19 QATRO-ELEC-ingeniería y servicios eléctricos
industriales S.L. : inscrita en el Registro Mercantil de A Coruña,
Tomo 3.139 del Archivo, Sección General, al folio 55, hoja número
C-39.770, inscripción 1ª, C.I.F. B70077896
COMMNON ELECTRICITY + INSTRUMENTATIÓN FOR … MAIN FEATURES
DIGITAL MULTIMETER MASTECH MY60
♦ Multifunction multimeter ♦
DIGITAL MULTIMETER MASTECH MY980
♦ Multifunction multimeter ♦
DIGITAL MULTIMETER METRIX MX22
♦ Multifunction multimeter ♦
ANALOGUE MULTIMETER HIBOK 64
♦ Multifunction multimeter ♦
ANALOGUE MULTIMETER METRA MAX6
♦ Multifunction multimeter ♦
-
TEST EQUIPMENT equipment 100 % owned by qatro In most test
equipment there are several units, allowing us to provide similar
services in different sites simultaneous
© QATRO-ELEC-ISEI S.L. QE\DpC\PR&PU\P\02-2 FECHA 021106 REV.
011114 HOJA 15 DE 19 QATRO-ELEC-ingeniería y servicios eléctricos
industriales S.L. : inscrita en el Registro Mercantil de A Coruña,
Tomo 3.139 del Archivo, Sección General, al folio 55, hoja número
C-39.770, inscripción 1ª, C.I.F. B70077896
COMMNON ELECTRICITY + INSTRUMENTATIÓN FOR … MAIN FEATURES
ANALOGUE MULTIMETER MASTECH YX-360 TRA
♦ Multifunction multimeter ♦
DIGITAL MULTIMETER GOSSEN / METRAWATT METRAHIT PRO
♦ Multifunction multimeter ♦
ANALOGUE MULTIMETER STANDARD ST-303TR
♦ Multifunction multimeter ♦
DIGITAL CLAMP GOSSEN / METRAWATT METRACLIP 70
♦ Multifunction clamp ♦
DIGITAL CLAMP SAMWA DCM2000
♦ Multifunction clamp ♦
-
TEST EQUIPMENT equipment 100 % owned by qatro In most test
equipment there are several units, allowing us to provide similar
services in different sites simultaneous
© QATRO-ELEC-ISEI S.L. QE\DpC\PR&PU\P\02-2 FECHA 021106 REV.
011114 HOJA 16 DE 19 QATRO-ELEC-ingeniería y servicios eléctricos
industriales S.L. : inscrita en el Registro Mercantil de A Coruña,
Tomo 3.139 del Archivo, Sección General, al folio 55, hoja número
C-39.770, inscripción 1ª, C.I.F. B70077896
COMMNON ELECTRICITY + INSTRUMENTATIÓN FOR … MAIN FEATURES
DIGITAL CLAMP MASTECH MS2001C
♦ Multifunction clamp ♦
LEAKAGE CURRENT CLAMP FLUKE 360
♦ Measurement of leakage currents (to earth) of the insulation
(dry, liquid and gaseous) of the electrical installations and of
leakage currents (to earth) of earthed filters for electronic
equipment ♦ Precision clamp meter
♦ Mean value detection and rms-value calibration ♦ Leakage
current clamp:
0 – 3 mAac (resolution 1 μAac) 0 – 30 mAac (resolution 10
μAac)
♦ Precision clamp meter: 0 – 30 Aac (resolution 0.01 Aac) 0 – 60
Aac (resolution 0.01 Aac)
♦ Accuracy specified at 50 ±1 Hz ♦ Frequency range 15 Hz to 150
Hz
PHASE ROTATION INDICATOR FLUKE 9040
♦ Check of the: → Direct / reverse voltage sequence (UFF) → Open
phase
♦ Sequence UFF ≡ sequence UFN ♦ U = 40 – 700 Vac ♦ 15 – 400 Hz ♦
CAT III – 600 V / CAT IV – 300 V
DIGITAL TIMER EUROSMC PTE-30-CH
♦ Measurement of times of: → Actuating in protection relays →
Presence or absence of signal (pulses)
♦ Seconds mode: 00.000 to 99,999 s ♦ Cycles mode: 0000.0 to
9,999.9 cycles ♦ Frequency mode: 20.000 to 4,000.0 Hz
BATTERY SIMULATOR EUROSMC PTE-FCG
♦ Functional testing of HV equipment: → Control circuits →
Command circuits → Supervision circuits → Electrical protection
equipment
especially in the absence of U voltage (VDC) system in the
plant
♦ 48 – 125 – 250 Vdc ♦ 60 W
-
TEST EQUIPMENT equipment 100 % owned by qatro In most test
equipment there are several units, allowing us to provide similar
services in different sites simultaneous
© QATRO-ELEC-ISEI S.L. QE\DpC\PR&PU\P\02-2 FECHA 021106 REV.
011114 HOJA 17 DE 19 QATRO-ELEC-ingeniería y servicios eléctricos
industriales S.L. : inscrita en el Registro Mercantil de A Coruña,
Tomo 3.139 del Archivo, Sección General, al folio 55, hoja número
C-39.770, inscripción 1ª, C.I.F. B70077896
COMMNON ELECTRICITY + INSTRUMENTATIÓN FOR … MAIN FEATURES POWER
SUPPLY TERMI 125V-240W
♦ Functional testing of HV equipment: → Control circuits →
Command circuits → Supervision circuits → Electrical protection
equipment → Switching of circuit breaking equipment (circuit
breakers, switches, load break switches, …)
especially in the absence of 125 Vdc voltage system in the
plant
♦ 125 Vdc ♦ 240 W ♦ Designed by QATRO
TACHOMETER MASTECH DT2234A
♦ Measurement of speed of rotating electrical machines
♦ 5 – 99,999 rpm
LIGHT METER GOERZ METRAWATT MX4
♦ Measurement of illumination ♦ 150 – 500 – 1,500 – 5,000
lux
WEATHER METER KESTREL AVM-4000
♦ Measure “in situ” of wind speed, temperature, relative
humidity, dewpoint, wind chill, heat index, barometric pressure,
station pressure, heat stress, date and time
♦ Wind Speed: 0.3 – 41 m/s 1 – 144 Km/h
♦ Temperature : – 29 to +70 °C ♦ Relative humidity: 5 – 95 % ♦
Barometric pressure:
870 – 1,080 HPa / mb
SOLAR RADIATION METER PCE SPM1
♦ Measurement “in situ” of solar energy and power insolation
Ptot (W/m2)
♦ Resolution : 1 W/m2 ♦ Accuracy : ±10 W/m² or ± 5 % ♦ Spectral
range: 400 – 1,100 nm ♦ Minimum, maximum and data hold functions♦
Memory : 32,000 readings
-
TEST EQUIPMENT equipment 100 % owned by qatro In most test
equipment there are several units, allowing us to provide similar
services in different sites simultaneous
© QATRO-ELEC-ISEI S.L. QE\DpC\PR&PU\P\02-2 FECHA 021106 REV.
011114 HOJA 18 DE 19 QATRO-ELEC-ingeniería y servicios eléctricos
industriales S.L. : inscrita en el Registro Mercantil de A Coruña,
Tomo 3.139 del Archivo, Sección General, al folio 55, hoja número
C-39.770, inscripción 1ª, C.I.F. B70077896
COMMNON ELECTRICITY + INSTRUMENTATIÓN FOR … MAIN FEATURES PHASE
ROTATION INDICATOR FLUKE 9040
♦ Check of the: → Direct / reverse voltage sequence (UFF) → Open
phase
♦ Sequence UFF ≡ sequence UFN ♦ U = 40 – 700 Vac ♦ 15 – 400 Hz ♦
CAT III – 600 V / CAT IV – 300 V
-
TEST EQUIPMENT equipment 100 % owned by qatro In most test
equipment there are several units, allowing us to provide similar
services in different sites simultaneous
© QATRO-ELEC-ISEI S.L. QE\DpC\PR&PU\P\02-2 FECHA 021106 REV.
011114 HOJA 19 DE 19 QATRO-ELEC-ingeniería y servicios eléctricos
industriales S.L. : inscrita en el Registro Mercantil de A Coruña,
Tomo 3.139 del Archivo, Sección General, al folio 55, hoja número
C-39.770, inscripción 1ª, C.I.F. B70077896
SAFETY
PERSONAL AND NOT TRANSFERABLE FOR … MEAN FEATURES DIGITAL
VOLTAGE TESTER 1 UNIT / QATRO TECHNICIAN
♦ All QATRO technicians have one : → Assigned personally
♦ Multifunction Electrical Tester
♦ According to our ORP management system:→ For personal safety →
For the safety of others → For effectiveness – efficiency in the
workplace.
♦ TESTBOY :
→ Uac / Udc : 6 – 1,000 V → 1,000 V / CAT IV → IP65
♦ FLUKE : → Uac / Udc : 12 – 690 V → 600 V / CAT IV → IP65
TESTBOY PROFI LCD PLUS
FLUKE T100
DIGITAL MULTIMETER 1 UNIT / RESPONSABLE TECHNICIAN OF THE SYSTEM
GOSSEN / METRAWATT METRAHIT 2+
♦ All QATRO technicians responsible have one:
→ Nominative, permanent and mandatory carry and use it for as
long as you are on site
♦ Voltage tester ♦ Multimeter
♦ According to our ORP management system:→ For personal safety →
For the safety of others
♦ According with our internal work procedures:
→ For measurements ♦ Basic features :
→ 600 V – CAT III → TRMS → Vac-dc : 600 mV – 600 V → Aac-dc : 60
mA – 10 A → Ω : 600 Ω – 40 MΩ → º C : – 50 – 400 → Hz : 0 – 1.000
Hz
WALKY-TALKY 1 UNIT / QATRO TECHNICIAN KENWOOD → TK-3201 →
TK-3301
♦ All QATRO technicians assigned to the testing and
commissioning of a plant, have one :
→ Assigned personally and continuing throughout the duration of
the work
♦ According to our ORP management system:→ For personal safety →
For the safety of others → For effectiveness – efficiency in the
workplace
MEDIDOR DE DISTANCIAS POR LASER 1 UNIDAD / SERVICIO BOSCH → DLE
50
♦ For all QATRO services, performed in air insulated electrical
installations (AIS) :
♦ In accordance with our H&S policy