Top Banner
162

Neuroradiologyd2qrtshcpf0x30.cloudfront.net/nodes/58/Neuroradiology of Seizure... · •Transmit/receive coil only • No scans with body coil or receive only coils •Pulse generator

Mar 21, 2020

Download

Documents

dariahiddleston
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: Neuroradiologyd2qrtshcpf0x30.cloudfront.net/nodes/58/Neuroradiology of Seizure... · •Transmit/receive coil only • No scans with body coil or receive only coils •Pulse generator
Page 2: Neuroradiologyd2qrtshcpf0x30.cloudfront.net/nodes/58/Neuroradiology of Seizure... · •Transmit/receive coil only • No scans with body coil or receive only coils •Pulse generator

Neuroradiology

Ted Passe, MDNeuroradiology

Mayo Clinic Rochester, MN

Page 3: Neuroradiologyd2qrtshcpf0x30.cloudfront.net/nodes/58/Neuroradiology of Seizure... · •Transmit/receive coil only • No scans with body coil or receive only coils •Pulse generator

Objectives

• Imaging modalities in epilepsy• Anatomic – CT/MRI• Functional – MRS, SPECT, PET, fMRI, MSI, DTI

• Characteristic imaging findings in epilepsy• Infectious / Inflammatory• Mesial Temporal Sclerosis• Malformations of Cortical Development• Vascular malformations• Neoplastic

• Methods of improved lesion detection • Dedicated seizure protocol• Higher resolution 3T MRI / 7T MRI• Subspecialized image interpretation

Page 4: Neuroradiologyd2qrtshcpf0x30.cloudfront.net/nodes/58/Neuroradiology of Seizure... · •Transmit/receive coil only • No scans with body coil or receive only coils •Pulse generator
Page 5: Neuroradiologyd2qrtshcpf0x30.cloudfront.net/nodes/58/Neuroradiology of Seizure... · •Transmit/receive coil only • No scans with body coil or receive only coils •Pulse generator

What is CT?

• CT=computed tomography

• CT is an X-ray based system

• A tube rotates around the patient projecting X-rays through the patient from many angles

• A ring of X-ray detectors collects an image from each projection angle around the patient

• 1st generation CT scanners had 1 detector. Newer CT scanners have multiple detectors (16, 32, 64, 256+) which allow increased speed and resolution

Page 6: Neuroradiologyd2qrtshcpf0x30.cloudfront.net/nodes/58/Neuroradiology of Seizure... · •Transmit/receive coil only • No scans with body coil or receive only coils •Pulse generator

History of CT

• Invented 1972 by engineer Godfrey Houndsfield

• EMI laboratories, England

• Nobel prize in Medicine 1979

• Knighted 1981

• Original axial CT image from a dedicated CT scanner circa 1975

• This image is a coarse 128 x 128 matrix

Page 8: Neuroradiologyd2qrtshcpf0x30.cloudfront.net/nodes/58/Neuroradiology of Seizure... · •Transmit/receive coil only • No scans with body coil or receive only coils •Pulse generator

EMI and The Beatles

• EMI, a British electronics and music company

• Better known as the record company for the Beatles

• $ to fund research into the development of the 1st CT scanner stemmed from $ from Beatles record sales

Page 9: Neuroradiologyd2qrtshcpf0x30.cloudfront.net/nodes/58/Neuroradiology of Seizure... · •Transmit/receive coil only • No scans with body coil or receive only coils •Pulse generator

CT Revolutionized Neuroradiology

Page 10: Neuroradiologyd2qrtshcpf0x30.cloudfront.net/nodes/58/Neuroradiology of Seizure... · •Transmit/receive coil only • No scans with body coil or receive only coils •Pulse generator

CT Then and Now

Page 11: Neuroradiologyd2qrtshcpf0x30.cloudfront.net/nodes/58/Neuroradiology of Seizure... · •Transmit/receive coil only • No scans with body coil or receive only coils •Pulse generator

CT Images

• Cross sectional images are made up of "pixels" (picture elements). Each 2D pixel represents a 3D "voxel" (volume element) of tissue being imaged

• Smaller pixels → higher resolution (think HD TV)

• A pixel represents the ability of the atoms within the voxel to attenuate (decrease) an X-ray beam

• Contrast varies with density of tissue

• Bone/metal=bright white

• Muscle=gray

• Air=black

• Pathological processes are identified by alterations in anatomy and attenuation

Page 12: Neuroradiologyd2qrtshcpf0x30.cloudfront.net/nodes/58/Neuroradiology of Seizure... · •Transmit/receive coil only • No scans with body coil or receive only coils •Pulse generator

Wooden Foreign Matter

• 18-yo female near to an explosion

• Wood fragment penetrated skull

Page 13: Neuroradiologyd2qrtshcpf0x30.cloudfront.net/nodes/58/Neuroradiology of Seizure... · •Transmit/receive coil only • No scans with body coil or receive only coils •Pulse generator

Head CT Indications in Epilepsy

• Emergent imaging necessary• If MRI not available

• If MRI contraindicated

• To evaluate for calcium

• MRI remains much more sensitive than CT in epilepsy workup

Page 14: Neuroradiologyd2qrtshcpf0x30.cloudfront.net/nodes/58/Neuroradiology of Seizure... · •Transmit/receive coil only • No scans with body coil or receive only coils •Pulse generator

What is MRI?

Page 15: Neuroradiologyd2qrtshcpf0x30.cloudfront.net/nodes/58/Neuroradiology of Seizure... · •Transmit/receive coil only • No scans with body coil or receive only coils •Pulse generator

What is MRI?

• Click to edit Master text styles– Second level

• Third level– Fourth level

» Fifth level

• Patient in powerful magnetic field

• Protons align with the field

• Gradients and RF pulses create signal

• Reflected RF signal received by coils

• Computer processing used to create images in multiple planes

• Unlike CT or CR, no ionizing radiation

Page 16: Neuroradiologyd2qrtshcpf0x30.cloudfront.net/nodes/58/Neuroradiology of Seizure... · •Transmit/receive coil only • No scans with body coil or receive only coils •Pulse generator

MRI Safety

• Static Magnetic Field: The powerful super-conducting magnetic field is the most dangerous aspect of MRI and is ALWAYS ON!!!

• External metal objects can become missiles

• Can turn off pacemakers or electrical devices

• Can dislodge/torque metal implants (eye, aneurysm clips)

• Can erase credit cards/magnetic cards

Page 17: Neuroradiologyd2qrtshcpf0x30.cloudfront.net/nodes/58/Neuroradiology of Seizure... · •Transmit/receive coil only • No scans with body coil or receive only coils •Pulse generator

Wheelchair in Magnet

Page 18: Neuroradiologyd2qrtshcpf0x30.cloudfront.net/nodes/58/Neuroradiology of Seizure... · •Transmit/receive coil only • No scans with body coil or receive only coils •Pulse generator

Oxygen Tank in Magnet

Page 19: Neuroradiologyd2qrtshcpf0x30.cloudfront.net/nodes/58/Neuroradiology of Seizure... · •Transmit/receive coil only • No scans with body coil or receive only coils •Pulse generator

Phone and Selfie Stick in Magnet

Page 20: Neuroradiologyd2qrtshcpf0x30.cloudfront.net/nodes/58/Neuroradiology of Seizure... · •Transmit/receive coil only • No scans with body coil or receive only coils •Pulse generator

MRI: Safety

• RF power deposition• Causes heating within the body

• Challenging issue at high field MRI as Specific Absorption Rate (SAR) proportional to square of Bo• RF deposition quadruples at 3T

• FDA SAR limit: 4 W/kg body and 3 W/kg head

• Limits pulse sequences (FSE - strong RF pulses)

• Neurostimulators are relatively contraindicated• Depth electrodes • Vagal nerve stimulators

Page 21: Neuroradiologyd2qrtshcpf0x30.cloudfront.net/nodes/58/Neuroradiology of Seizure... · •Transmit/receive coil only • No scans with body coil or receive only coils •Pulse generator

RF-induced Burns at Cardiac Leads

Page 22: Neuroradiologyd2qrtshcpf0x30.cloudfront.net/nodes/58/Neuroradiology of Seizure... · •Transmit/receive coil only • No scans with body coil or receive only coils •Pulse generator

VNS Safety

• Safety guidelines required for VNS as MRI can:• Induce heat in the VNS lead – tissue injury

• Change pulse generator settings or activate device

• MRI Protocol:• Transmit/receive coil only

• No scans with body coil or receive only coils

• Pulse generator output programmed to 0 mA before MRI and reprogrammed after MRI

• Static MRI field less than or equal to 3 Tesla

• SAR less than 1.3 W/kg

• Time – varying intensity: less than 10 Tesla/sec

Page 23: Neuroradiologyd2qrtshcpf0x30.cloudfront.net/nodes/58/Neuroradiology of Seizure... · •Transmit/receive coil only • No scans with body coil or receive only coils •Pulse generator

ConventionalMRI

Sag T1

Ax FLAIR

Ax Diffusion Weighted

Image

Cor T2

Ax T2

Page 24: Neuroradiologyd2qrtshcpf0x30.cloudfront.net/nodes/58/Neuroradiology of Seizure... · •Transmit/receive coil only • No scans with body coil or receive only coils •Pulse generator

“Standard Magnetic Resonance Imaging is Inadequate for Patients With Refractory Focal Epilepsy”

Sensitivity of lesion detection in medically refractory epilepsy:

1. 39% non-expert radiologist on standard MRI2. 50% experienced neuroradiologist (>3 yrs

epilepsy center) standard MRI → +11%3. 85% experienced neuroradiologist with focused

Epilepsy MRI → +46%

Note: most problems with under-detection, #1 MTS, #2 focal cortical dysplasia

Von Oertzen, et al. J Neurol Neurosurg Psychiatry. 2002.

Page 25: Neuroradiologyd2qrtshcpf0x30.cloudfront.net/nodes/58/Neuroradiology of Seizure... · •Transmit/receive coil only • No scans with body coil or receive only coils •Pulse generator

Seizure Protocol

• Routine head• Sag T1 FLAIR, Ax T2 , Ax FLAIR, Ax DWI

• Cor Hi Res T2 FSE (3 mm) – Assess architectural distortion

• Cor FLAIR – Assess for increased signal

• Cor SPGR 3D volume –• Assess for hippocampal atrophy• Qualitative and/or quantitative

• GRE and/or SWI – Assess for chronic hemorrhage

• Double IR – Increased sensitivity for cortical dysplasia

• DTI - FA maps routine, tractography case by case

• Gadolinium for tumor, AVM or neurocutaneous syndromes

Page 26: Neuroradiologyd2qrtshcpf0x30.cloudfront.net/nodes/58/Neuroradiology of Seizure... · •Transmit/receive coil only • No scans with body coil or receive only coils •Pulse generator

Advanced Imaging Techniques in Epilepsy

• A patient with Epilepsy may be classified as nonlesional for 2 reasons:

• 1) A lesion may not exist; that is, the structural abnormality that gives rise to seizures may be at the channel level or be spatially distributed in such a way that it would not be accurately termed a lesion, or

• 2) A lesion exists but is so subtle that standard clinical imaging is not sensitive enough to discriminate between the lesion and surrounding healthy brain tissue. As with any technology and disease, this definition is dynamic, as that future imaging techniques will be developed and new disease mechanisms will be discovered, making detection of the epileptogenic underlying abnormality an ever-changing target.

• Goal to move each patient from non-lesional to lesional epilepsy

Pardoe H, Kuzniecky R. Epilepsy Curr. 2014.

Page 27: Neuroradiologyd2qrtshcpf0x30.cloudfront.net/nodes/58/Neuroradiology of Seizure... · •Transmit/receive coil only • No scans with body coil or receive only coils •Pulse generator

Hi Resolution 3D Volume MRI

Page 28: Neuroradiologyd2qrtshcpf0x30.cloudfront.net/nodes/58/Neuroradiology of Seizure... · •Transmit/receive coil only • No scans with body coil or receive only coils •Pulse generator

3T (and now 7T) MRI

• FDA approved 3T MRI in 2001

• October 2017 – 1st FDA clinical MRI at Mayo Clinic

• 7 Tesla=140,000 X Earth’s magnetic field

• Boltzmann equation: S/N ~ Bo

• Other MR improvements – (not just 3T)• Coil technology

• Gradient technology

• Computing power

Page 29: Neuroradiologyd2qrtshcpf0x30.cloudfront.net/nodes/58/Neuroradiology of Seizure... · •Transmit/receive coil only • No scans with body coil or receive only coils •Pulse generator

3T Superior to 1.5T in Epilepsy Evaluation

• Retrospective study of 25 epilepsy patients

• 3T correctly identified structural lesions in 88% of epilepsy patients vs. 74% at 1.5T

• 3T also had significantly better:• Lesion conspicuity

• Tissue contrast

Phal PM, et al. AJR Am J Roentgenol. 2008.

Page 30: Neuroradiologyd2qrtshcpf0x30.cloudfront.net/nodes/58/Neuroradiology of Seizure... · •Transmit/receive coil only • No scans with body coil or receive only coils •Pulse generator

1.5T SPGR 3T SPGR

MTS 1.5T vs. 3T

Page 31: Neuroradiologyd2qrtshcpf0x30.cloudfront.net/nodes/58/Neuroradiology of Seizure... · •Transmit/receive coil only • No scans with body coil or receive only coils •Pulse generator

MTS 1.5T vs. 3T

1.5T - Hi Res T2 3T – Hi Res T2

Page 32: Neuroradiologyd2qrtshcpf0x30.cloudfront.net/nodes/58/Neuroradiology of Seizure... · •Transmit/receive coil only • No scans with body coil or receive only coils •Pulse generator

7T vs 3T

7T Sag DIR 3T Sag DIR

Page 33: Neuroradiologyd2qrtshcpf0x30.cloudfront.net/nodes/58/Neuroradiology of Seizure... · •Transmit/receive coil only • No scans with body coil or receive only coils •Pulse generator

Double Inversion Recovery (DIR)

• DIR significantly improves conspicuity of epileptogenic lesions compared to FLAIR1

• DIR demonstrates increased sensitivity to cortical dysplasia and is complementary to MPRAGE.2

1Kattumannarkudi R, et al. RSNA. 2014. Abstract 429; 2Wong-Kisiel LC, et al. Pediatr Neurol. 2016.

Page 34: Neuroradiologyd2qrtshcpf0x30.cloudfront.net/nodes/58/Neuroradiology of Seizure... · •Transmit/receive coil only • No scans with body coil or receive only coils •Pulse generator

Double Inversion Recovery (DIR)

Sag DIR (7T) Sag T1 MPRAGE (7T)

Page 35: Neuroradiologyd2qrtshcpf0x30.cloudfront.net/nodes/58/Neuroradiology of Seizure... · •Transmit/receive coil only • No scans with body coil or receive only coils •Pulse generator

Brief Summary

• Structural imaging • MRI better than CT

• Improve lesion detection via:• Use dedicated seizure protocol

• Use 3T or 7T MRI if available

• Review by experienced neuroradiologist

Page 36: Neuroradiologyd2qrtshcpf0x30.cloudfront.net/nodes/58/Neuroradiology of Seizure... · •Transmit/receive coil only • No scans with body coil or receive only coils •Pulse generator

Epilepsy: Pathologic Substrates

• Infectious/inflammatory

• Mesial Temporal Sclerosis

• Malformations of cortical development

• Vascular malformations

• Neoplastic

Page 37: Neuroradiologyd2qrtshcpf0x30.cloudfront.net/nodes/58/Neuroradiology of Seizure... · •Transmit/receive coil only • No scans with body coil or receive only coils •Pulse generator

26-yo Male: New Onset Seizure

Page 38: Neuroradiologyd2qrtshcpf0x30.cloudfront.net/nodes/58/Neuroradiology of Seizure... · •Transmit/receive coil only • No scans with body coil or receive only coils •Pulse generator

What is the imaging diagnosis?

Page 39: Neuroradiologyd2qrtshcpf0x30.cloudfront.net/nodes/58/Neuroradiology of Seizure... · •Transmit/receive coil only • No scans with body coil or receive only coils •Pulse generator

Neurocysticercosis

• #1 cause of adult-onset seizure worldwide

• Dissemination of the pork tapeworm larva

• Increasing incidence in US

• CT – classic calcified scolex

• Transient worsening with antiparasitic tx• Vasogenic edema

Page 40: Neuroradiologyd2qrtshcpf0x30.cloudfront.net/nodes/58/Neuroradiology of Seizure... · •Transmit/receive coil only • No scans with body coil or receive only coils •Pulse generator

Disseminated Neurocysticercosis

Page 41: Neuroradiologyd2qrtshcpf0x30.cloudfront.net/nodes/58/Neuroradiology of Seizure... · •Transmit/receive coil only • No scans with body coil or receive only coils •Pulse generator

Racemose Cysticercosis

Page 42: Neuroradiologyd2qrtshcpf0x30.cloudfront.net/nodes/58/Neuroradiology of Seizure... · •Transmit/receive coil only • No scans with body coil or receive only coils •Pulse generator

39-yo Female: Seizure, Confused

Page 43: Neuroradiologyd2qrtshcpf0x30.cloudfront.net/nodes/58/Neuroradiology of Seizure... · •Transmit/receive coil only • No scans with body coil or receive only coils •Pulse generator

39-yo Female: Seizure and ConfusedMRI 4 Days Later

FLAIR Diffusion Gradient Echo

Page 44: Neuroradiologyd2qrtshcpf0x30.cloudfront.net/nodes/58/Neuroradiology of Seizure... · •Transmit/receive coil only • No scans with body coil or receive only coils •Pulse generator

MRI 2 Days Later

FLAIR FLAIR Cor T2

Page 45: Neuroradiologyd2qrtshcpf0x30.cloudfront.net/nodes/58/Neuroradiology of Seizure... · •Transmit/receive coil only • No scans with body coil or receive only coils •Pulse generator

Herpes Encephalitis – Adult

• #1 cause of sporadic viral encephalitis

• Overall rare: 3 cases/100,000/year

• Adults – HSV-1

• Retrograde spread of latent virus from a peripheral ganglion (trigeminal/olfactory)

• Involves limbic system, temporal and frontal lobes

• Untreated 70% mortality

• Treatment: IV acyclovir

• Treated: 40% recover w/o deficit; 30% mortality

Page 46: Neuroradiologyd2qrtshcpf0x30.cloudfront.net/nodes/58/Neuroradiology of Seizure... · •Transmit/receive coil only • No scans with body coil or receive only coils •Pulse generator

Ax T2 Ax T2

70-yo Female with Memory Problems and Seizure

Page 47: Neuroradiologyd2qrtshcpf0x30.cloudfront.net/nodes/58/Neuroradiology of Seizure... · •Transmit/receive coil only • No scans with body coil or receive only coils •Pulse generator

FLAIR FLAIR

70-yo Female with Memory Problems and Seizure

Page 48: Neuroradiologyd2qrtshcpf0x30.cloudfront.net/nodes/58/Neuroradiology of Seizure... · •Transmit/receive coil only • No scans with body coil or receive only coils •Pulse generator

Diffusion Diffusion

70-yo Female with Memory Problems and Seizure

Page 49: Neuroradiologyd2qrtshcpf0x30.cloudfront.net/nodes/58/Neuroradiology of Seizure... · •Transmit/receive coil only • No scans with body coil or receive only coils •Pulse generator

Creutzfeldt – Jakob Disease

T2 FLAIR Diffusion

Page 50: Neuroradiologyd2qrtshcpf0x30.cloudfront.net/nodes/58/Neuroradiology of Seizure... · •Transmit/receive coil only • No scans with body coil or receive only coils •Pulse generator

Creutzfeldt – Jakob Disease

• Progressively fatal spongiform encephalopathy

• Prion protein – causative agent

• Rare: 1/million/year

• Rapidly progressive dementia, myoclonic jerks

• MR: increased signal caudate, putamen, cortex

• DWI>FLAIR>T2 sensitivity

Page 51: Neuroradiologyd2qrtshcpf0x30.cloudfront.net/nodes/58/Neuroradiology of Seizure... · •Transmit/receive coil only • No scans with body coil or receive only coils •Pulse generator

Confusion While Tapering AEDs

Page 52: Neuroradiologyd2qrtshcpf0x30.cloudfront.net/nodes/58/Neuroradiology of Seizure... · •Transmit/receive coil only • No scans with body coil or receive only coils •Pulse generator

Confusion While Tapering AEDs

Sag T1 Sag FLAIR

Page 53: Neuroradiologyd2qrtshcpf0x30.cloudfront.net/nodes/58/Neuroradiology of Seizure... · •Transmit/receive coil only • No scans with body coil or receive only coils •Pulse generator

Transient Splenium Lesions /Cytotoxic Lesions of the Corpus Callosum

(CLOCCs)• Pathophysiology of this lesion in the SCC in patients with epilepsy or on

AEDs remains unknown

• Postulated to be due to increased glutamate causing influx of intracellular water preferential to splenium due to high density of oligodendrocytes with glutamate receptors

• Lesions of the SCC on MRI appear to be a benign, rare finding, not requiring specific treatment, although follow-up MRI may be reassuring

• Associated with seizures and classically the rapid taper of AEDs may be a factor contributing the development of a lesion in the SCC in patients on AEDs

• Association with Influenza, Migraine with Aura, etc…

• Typically asymptomatic and transient / reversible on imaging in 1 week to 1 month

Page 54: Neuroradiologyd2qrtshcpf0x30.cloudfront.net/nodes/58/Neuroradiology of Seizure... · •Transmit/receive coil only • No scans with body coil or receive only coils •Pulse generator

Transient Splenium Lesions

Ovoid or boomerang sign

Page 55: Neuroradiologyd2qrtshcpf0x30.cloudfront.net/nodes/58/Neuroradiology of Seizure... · •Transmit/receive coil only • No scans with body coil or receive only coils •Pulse generator

Hippocampal Diffusion Abnormality

Recent or ongoing seizure activity / Status Epilepticus

Page 56: Neuroradiologyd2qrtshcpf0x30.cloudfront.net/nodes/58/Neuroradiology of Seizure... · •Transmit/receive coil only • No scans with body coil or receive only coils •Pulse generator

Pulvinar Abnormality 17 / 224 seizure patients – all had status

MRI abnormality of the pulvinar in patients with status epilepticus -

Ohe Y, et al, J Neuroradiol. 2014.

Page 57: Neuroradiologyd2qrtshcpf0x30.cloudfront.net/nodes/58/Neuroradiology of Seizure... · •Transmit/receive coil only • No scans with body coil or receive only coils •Pulse generator

Sudden Onset Left Sided Numbness and Confusion

Page 58: Neuroradiologyd2qrtshcpf0x30.cloudfront.net/nodes/58/Neuroradiology of Seizure... · •Transmit/receive coil only • No scans with body coil or receive only coils •Pulse generator

PCA Occlusion with Acute Infarcts

Page 59: Neuroradiologyd2qrtshcpf0x30.cloudfront.net/nodes/58/Neuroradiology of Seizure... · •Transmit/receive coil only • No scans with body coil or receive only coils •Pulse generator

Autoimmune Epilepsy

• Frequent cause of epilepsy of unknown etiology

• Paraneoplastic and non-paraneoplastic groups

• Common neural specific antibodies LGI1, NMDA-R, Gad65 IgG

• Potentially treatable with immunotherapy

• Limbic system (limbic encaphalitis) most common but cortex, cerebellum and basal ganglia all can be involved

• Acute phase – Edema / hypermetabolic PET

• Chronic phase – gliosis (MTS) / hypometabolic PET

Fang Z, et al. Front Immunol. 2017; Kelley BP, et al. AJNR Am J Neuroradiol. 2017.

Page 60: Neuroradiologyd2qrtshcpf0x30.cloudfront.net/nodes/58/Neuroradiology of Seizure... · •Transmit/receive coil only • No scans with body coil or receive only coils •Pulse generator

Autoimmune Epilepsy

• 64 year old Myasthenia Gravis

• New cognitive decline

• Subclinical left temporal lobe seizures on EEG

Page 61: Neuroradiologyd2qrtshcpf0x30.cloudfront.net/nodes/58/Neuroradiology of Seizure... · •Transmit/receive coil only • No scans with body coil or receive only coils •Pulse generator

MRI

Page 62: Neuroradiologyd2qrtshcpf0x30.cloudfront.net/nodes/58/Neuroradiology of Seizure... · •Transmit/receive coil only • No scans with body coil or receive only coils •Pulse generator

FDG-PET

Page 63: Neuroradiologyd2qrtshcpf0x30.cloudfront.net/nodes/58/Neuroradiology of Seizure... · •Transmit/receive coil only • No scans with body coil or receive only coils •Pulse generator

30-yo with Partial Complex Seizures; Right Temporal Lobe Abnormal EEG

3T Cor SPGR 3T Cor Hi Res T2

Page 64: Neuroradiologyd2qrtshcpf0x30.cloudfront.net/nodes/58/Neuroradiology of Seizure... · •Transmit/receive coil only • No scans with body coil or receive only coils •Pulse generator

Mesial Temporal Sclerosis (MTS)

• Primary findings: hippocampal atrophy and gliosis• Atrophy on Cor SPGR T1

• Increased FLAIR signal• T2 increased signal and

architectural distortion

• Secondary findings• Enlargement of ipsilateral

temporal horn/choroidal fissure

• Thinning of fornix

• Atrophy of mammilary body• Loss of normal interdigitations of

hippocampal head

Page 65: Neuroradiologyd2qrtshcpf0x30.cloudfront.net/nodes/58/Neuroradiology of Seizure... · •Transmit/receive coil only • No scans with body coil or receive only coils •Pulse generator

Dual Pathology – 5%-20% of MTS Patients Have an Extra-hippocampal Lesion

Post-traumatic encephalomalaciaand gliosis

Left MTS

Page 66: Neuroradiologyd2qrtshcpf0x30.cloudfront.net/nodes/58/Neuroradiology of Seizure... · •Transmit/receive coil only • No scans with body coil or receive only coils •Pulse generator

MTS Dual Pathology

Page 67: Neuroradiologyd2qrtshcpf0x30.cloudfront.net/nodes/58/Neuroradiology of Seizure... · •Transmit/receive coil only • No scans with body coil or receive only coils •Pulse generator

MTS Dual Pathology

Page 68: Neuroradiologyd2qrtshcpf0x30.cloudfront.net/nodes/58/Neuroradiology of Seizure... · •Transmit/receive coil only • No scans with body coil or receive only coils •Pulse generator

Temporal Encephalocele - 1

• Temporal encephaloceles increasingly visualized during neuroimaging assessment of patients with refractory epilepsy and could indicate potential seizure focus.

• 52 of 434 cases reviewed by expert (only 7 initially reported)

• 3T more sensitive

• Hi resolution T2 weighted sequences most sensitive

• Associated with findings of idiopathic intracranial hypertension

• Associated with temporal lobe seizures

Campbell AM, et al. AJNR J Neuroradiol. 2018.

Page 69: Neuroradiologyd2qrtshcpf0x30.cloudfront.net/nodes/58/Neuroradiology of Seizure... · •Transmit/receive coil only • No scans with body coil or receive only coils •Pulse generator

Temporal Encephalocele - 2

• 8 year study – 23 patients with encephalocele

• 0.3% first time seizure MRI

• 1.9% refractory epilepsy cases

• 12 went to surgery, 9 seizure free, 3 improved

Saavalainen, T et al. Neurology. 2015.

Page 70: Neuroradiologyd2qrtshcpf0x30.cloudfront.net/nodes/58/Neuroradiology of Seizure... · •Transmit/receive coil only • No scans with body coil or receive only coils •Pulse generator

Temporal Encephalocele

Page 71: Neuroradiologyd2qrtshcpf0x30.cloudfront.net/nodes/58/Neuroradiology of Seizure... · •Transmit/receive coil only • No scans with body coil or receive only coils •Pulse generator

Malformations of Cortical Development

Page 72: Neuroradiologyd2qrtshcpf0x30.cloudfront.net/nodes/58/Neuroradiology of Seizure... · •Transmit/receive coil only • No scans with body coil or receive only coils •Pulse generator

Malformations of Cortical Development

• Common finding in intractable epilepsy

• 3 categories of MCD depending on stage of brain maturation when insult occurred

1. Neuronal and glial proliferation (<10 wks)• Microcephaly, hemimegalencephaly, Tuberous Sclerosis

2. Neuronal migration (10-20 wks)• Heterotopias – nodular, band heterotopia, lissencephaly

3. Late cortical organization (>20 wks)• Polymicrogyria, schizencephaly, cortical dysplasia

Page 73: Neuroradiologyd2qrtshcpf0x30.cloudfront.net/nodes/58/Neuroradiology of Seizure... · •Transmit/receive coil only • No scans with body coil or receive only coils •Pulse generator

11-yo Boy with Seizure Disorder

Page 74: Neuroradiologyd2qrtshcpf0x30.cloudfront.net/nodes/58/Neuroradiology of Seizure... · •Transmit/receive coil only • No scans with body coil or receive only coils •Pulse generator

Tuberous Sclerosis

• Subependymal nodules• Glial/neuronal cells, often

calcify

• Cortical/subcortical tubers• Balloon cell migrational

anomaly• Triangle shape, apex toward

ventricle• T2 hyperintensity radiates

toward ventricle

• Subependymal Giant Cell Astrocytoma (SEGA)• Enhancing nodule at foramen

of Monro• Can cause obstructive

hydrocephalus

Page 75: Neuroradiologyd2qrtshcpf0x30.cloudfront.net/nodes/58/Neuroradiology of Seizure... · •Transmit/receive coil only • No scans with body coil or receive only coils •Pulse generator

Nodular Grey Matter Heterotopia

• Subependymal and/or subcortical WM

• Round/oval nodules

• Follow grey matter on all MR pulse sequences

• If bilateral, associated with cognitive delay

• Seizure-free outcome after temporal lobe epilepsy is poor, if nodule not resected

Page 76: Neuroradiologyd2qrtshcpf0x30.cloudfront.net/nodes/58/Neuroradiology of Seizure... · •Transmit/receive coil only • No scans with body coil or receive only coils •Pulse generator

Nodular Gray Matter Heterotopia –3T

25-yo female with a seizure disorder

Page 77: Neuroradiologyd2qrtshcpf0x30.cloudfront.net/nodes/58/Neuroradiology of Seizure... · •Transmit/receive coil only • No scans with body coil or receive only coils •Pulse generator

Chronic Seizures – 1.5T vs. 3T MRI

1.5T 3T

Page 78: Neuroradiologyd2qrtshcpf0x30.cloudfront.net/nodes/58/Neuroradiology of Seizure... · •Transmit/receive coil only • No scans with body coil or receive only coils •Pulse generator

Chronic Seizures – 1.5T vs. 3T MRI

1.5T 3T

Page 79: Neuroradiologyd2qrtshcpf0x30.cloudfront.net/nodes/58/Neuroradiology of Seizure... · •Transmit/receive coil only • No scans with body coil or receive only coils •Pulse generator

Agyria-Pachygyria-Band Spectrum of Cortical Malformations

• Spectrum of disorders caused by deficient neuronal migration during embryogenesis.

• Mutation in LIS1 gene and DCX gene • LIS1 mutation – post to ant gradient of abnormality

• DCX mutation – ant to post gradient of abnormality

Dobyns WB, Das S. LIS1-Associated Lissencephaly/Subcortical Band Heterotopia. 2009 Mar 3 [Updated 2014 Aug 14]. In: Pagon RA, Adam MP, Ardinger HH, et al., editors. GeneReviews® [Internet]. Seattle (WA):

University of Washington, Seattle; 1993-2015.

Page 80: Neuroradiologyd2qrtshcpf0x30.cloudfront.net/nodes/58/Neuroradiology of Seizure... · •Transmit/receive coil only • No scans with body coil or receive only coils •Pulse generator

Lissencephaly (Smooth Brain)

• Reduced sulcation – decreased number + depth of sulci

• Classic “figure 8” appearance

• Interfere with translocation of migrating neurons along radial glial cells to cortex

• Mutation in LIS1 gene and DCX gene • LIS1 mutation – parieto-occipital

region• DCX mutation – frontal lobes

4-yo female – seizure disorder

Page 81: Neuroradiologyd2qrtshcpf0x30.cloudfront.net/nodes/58/Neuroradiology of Seizure... · •Transmit/receive coil only • No scans with body coil or receive only coils •Pulse generator

Subcortical Band Heterotopia

• SBH due to milder mutation of LIS1 or DCX• Frontal – DCX

• Parieto-occipital – LIS1

• Thick or thin band of gray matter in white matter parallel to normal appearing cortex

• Poor surgical outcome

6-yo female – dev delay + seizures

Page 82: Neuroradiologyd2qrtshcpf0x30.cloudfront.net/nodes/58/Neuroradiology of Seizure... · •Transmit/receive coil only • No scans with body coil or receive only coils •Pulse generator

Subcortical Band Heterotopia

FLAIR T1 T2

18-yo female with chronic seizure disorder

Page 83: Neuroradiologyd2qrtshcpf0x30.cloudfront.net/nodes/58/Neuroradiology of Seizure... · •Transmit/receive coil only • No scans with body coil or receive only coils •Pulse generator

Subtle Case Example

• 24 year old female with drug resistant epilepsy, onset at age 21, staring spells initially progressing to tonic/clonic seizures.

• Outside MRI read as normal.

Page 84: Neuroradiologyd2qrtshcpf0x30.cloudfront.net/nodes/58/Neuroradiology of Seizure... · •Transmit/receive coil only • No scans with body coil or receive only coils •Pulse generator

3T MRI

FFLAIR T2

Page 85: Neuroradiologyd2qrtshcpf0x30.cloudfront.net/nodes/58/Neuroradiology of Seizure... · •Transmit/receive coil only • No scans with body coil or receive only coils •Pulse generator

3T MRI

DIR T1-MPRAGE

Page 86: Neuroradiologyd2qrtshcpf0x30.cloudfront.net/nodes/58/Neuroradiology of Seizure... · •Transmit/receive coil only • No scans with body coil or receive only coils •Pulse generator

3T vs 7T

3T 7T

Page 87: Neuroradiologyd2qrtshcpf0x30.cloudfront.net/nodes/58/Neuroradiology of Seizure... · •Transmit/receive coil only • No scans with body coil or receive only coils •Pulse generator

25 Year Old Male – Chronic Seizures

LIS1 associated band heterotopia

Page 88: Neuroradiologyd2qrtshcpf0x30.cloudfront.net/nodes/58/Neuroradiology of Seizure... · •Transmit/receive coil only • No scans with body coil or receive only coils •Pulse generator

Focal Cortical Dysplasia

• Abnormal cortical lamination

• Blurring grey – white matter junction

• Increased T2/FLAIR signal

• Cortical thickening on 3 contiguous slices

• Can be subtle or not visible on MRI

13-yo female with seizure disorder

FA Map T2

Page 89: Neuroradiologyd2qrtshcpf0x30.cloudfront.net/nodes/58/Neuroradiology of Seizure... · •Transmit/receive coil only • No scans with body coil or receive only coils •Pulse generator

Polymicrogyria

• Malformation of late cortical organization

• Excessive small gyri and sulci• Focal – limited or extensive• Multifocal• Bilateral and symmetric vs.

asymmetric• Diffuse

• MRI – bumpy irregular cortical surface and subcortical junction

Page 90: Neuroradiologyd2qrtshcpf0x30.cloudfront.net/nodes/58/Neuroradiology of Seizure... · •Transmit/receive coil only • No scans with body coil or receive only coils •Pulse generator

Polymicrogyria 1999 vs 2007

Page 91: Neuroradiologyd2qrtshcpf0x30.cloudfront.net/nodes/58/Neuroradiology of Seizure... · •Transmit/receive coil only • No scans with body coil or receive only coils •Pulse generator

Schizencephaly

• CSF cleft from subarachnoid space to lateral ventricle lined by dysplastic cortex/polymicrogyria

• Closed lip vs. open lip – open lip worse prognosis

• 1/3 bilateral (worse prognosis)

• Imaging DDX vs. porencephaly(no gray matter lining)

• Small dimple in ventricle wall

Page 92: Neuroradiologyd2qrtshcpf0x30.cloudfront.net/nodes/58/Neuroradiology of Seizure... · •Transmit/receive coil only • No scans with body coil or receive only coils •Pulse generator

Intractable Epilepsy

Page 93: Neuroradiologyd2qrtshcpf0x30.cloudfront.net/nodes/58/Neuroradiology of Seizure... · •Transmit/receive coil only • No scans with body coil or receive only coils •Pulse generator

Cavernous Malformations

• Most common vascular malformation associated with epilepsy

• Identify with MRI

• Get GRE to assess for other lesions

• Can be hereditary

• Can be symptomatic due to bleed

Page 94: Neuroradiologyd2qrtshcpf0x30.cloudfront.net/nodes/58/Neuroradiology of Seizure... · •Transmit/receive coil only • No scans with body coil or receive only coils •Pulse generator

Chronic Hemorrhage – GRE Blooming

55-yo female with seizures

Page 95: Neuroradiologyd2qrtshcpf0x30.cloudfront.net/nodes/58/Neuroradiology of Seizure... · •Transmit/receive coil only • No scans with body coil or receive only coils •Pulse generator

Susceptibility Weighted Imaging -SWI

SWI GRE FSE – T2

Page 96: Neuroradiologyd2qrtshcpf0x30.cloudfront.net/nodes/58/Neuroradiology of Seizure... · •Transmit/receive coil only • No scans with body coil or receive only coils •Pulse generator

MRI – AVM

Page 97: Neuroradiologyd2qrtshcpf0x30.cloudfront.net/nodes/58/Neuroradiology of Seizure... · •Transmit/receive coil only • No scans with body coil or receive only coils •Pulse generator

13-yo Female – Seizures

Page 98: Neuroradiologyd2qrtshcpf0x30.cloudfront.net/nodes/58/Neuroradiology of Seizure... · •Transmit/receive coil only • No scans with body coil or receive only coils •Pulse generator

13-yo Female – Seizures

Page 99: Neuroradiologyd2qrtshcpf0x30.cloudfront.net/nodes/58/Neuroradiology of Seizure... · •Transmit/receive coil only • No scans with body coil or receive only coils •Pulse generator

13-yo Female – Seizures

Page 100: Neuroradiologyd2qrtshcpf0x30.cloudfront.net/nodes/58/Neuroradiology of Seizure... · •Transmit/receive coil only • No scans with body coil or receive only coils •Pulse generator

Sturge Weber Syndrome

• AKA encephalotrigeminal angiomatosis

• Port wine stain V1 and V2 distribution • Orbit and forehead region

• Ipsilateral Leptomeningeal Angiomatosis• Abnormal venous drainage pattern

• Typically parietooccipital region

• Ipsilateral choroid plexus enlargement

Page 101: Neuroradiologyd2qrtshcpf0x30.cloudfront.net/nodes/58/Neuroradiology of Seizure... · •Transmit/receive coil only • No scans with body coil or receive only coils •Pulse generator

Neoplasms

• Source in 20% of intractable epilepsy

• Typically low grade

• Typically cortical location

• 2/3 temporal lobe

Page 102: Neuroradiologyd2qrtshcpf0x30.cloudfront.net/nodes/58/Neuroradiology of Seizure... · •Transmit/receive coil only • No scans with body coil or receive only coils •Pulse generator

Common Epileptogenic Tumors

• Low grade astrocytoma• Fibrillary vs. pilocytic

• Oligodengroglioma

• Ganglioglioma

• Dysembryoplastic Neuroepithelial Tumor (DNET)

• Pleomorphic Xanthoastrocytoma (PXA)

Page 103: Neuroradiologyd2qrtshcpf0x30.cloudfront.net/nodes/58/Neuroradiology of Seizure... · •Transmit/receive coil only • No scans with body coil or receive only coils •Pulse generator

32-yo Female – Long History of Seizures; Prior Head CT Report Normal

Page 104: Neuroradiologyd2qrtshcpf0x30.cloudfront.net/nodes/58/Neuroradiology of Seizure... · •Transmit/receive coil only • No scans with body coil or receive only coils •Pulse generator

Ganglioglioma

Page 105: Neuroradiologyd2qrtshcpf0x30.cloudfront.net/nodes/58/Neuroradiology of Seizure... · •Transmit/receive coil only • No scans with body coil or receive only coils •Pulse generator

19-yo Male: New-onset Seizure

Cor SPGR T1 Cor FLAIR Cor Hi Res T2

Page 106: Neuroradiologyd2qrtshcpf0x30.cloudfront.net/nodes/58/Neuroradiology of Seizure... · •Transmit/receive coil only • No scans with body coil or receive only coils •Pulse generator

53-yo Male: New-onset Seizures

Path = Glioblastoma

Page 107: Neuroradiologyd2qrtshcpf0x30.cloudfront.net/nodes/58/Neuroradiology of Seizure... · •Transmit/receive coil only • No scans with body coil or receive only coils •Pulse generator

58-yo Female: New-onset Seizure

Metastasis

Page 108: Neuroradiologyd2qrtshcpf0x30.cloudfront.net/nodes/58/Neuroradiology of Seizure... · •Transmit/receive coil only • No scans with body coil or receive only coils •Pulse generator

4-yo Female: New-onset Seizure

Page 109: Neuroradiologyd2qrtshcpf0x30.cloudfront.net/nodes/58/Neuroradiology of Seizure... · •Transmit/receive coil only • No scans with body coil or receive only coils •Pulse generator

Stealth Localization MRI

• Initial DDX• Dysplastic changes

• Low grade neoplasm

• Localization MRI• Signal gone…

• Edema due to seizure activity and/or encephalitis

Page 110: Neuroradiologyd2qrtshcpf0x30.cloudfront.net/nodes/58/Neuroradiology of Seizure... · •Transmit/receive coil only • No scans with body coil or receive only coils •Pulse generator

Functional Imaging Modalities

• MRI-based

• MR spectroscopy

• Functional MRI

• Diffusion Tensor Imaging/Tractography

• Nuclear medicine

• PET

• SPECT

• Magnetoencephalography/Magnetic Source Imaging

Page 111: Neuroradiologyd2qrtshcpf0x30.cloudfront.net/nodes/58/Neuroradiology of Seizure... · •Transmit/receive coil only • No scans with body coil or receive only coils •Pulse generator

MR Spectroscopy

• MR Imaging and MR Spectroscopy differ only in the manner in which the data are processed and presented

• MRS obtains metabolite peaks rather than images

• Allows non-invasive sampling of brain’s chemical environment

• Single voxel and multivoxel techniques

Page 112: Neuroradiologyd2qrtshcpf0x30.cloudfront.net/nodes/58/Neuroradiology of Seizure... · •Transmit/receive coil only • No scans with body coil or receive only coils •Pulse generator

MR Spectroscopy in Epilepsy

• Primary use in TLE

• Decreased NAA (a putative neuronal cell marker) due to neuronal loss

• Increase choline – gliosis

• Best marker – NAA/(Cho + Cr) ratio

• 90% correct lateralization in TLE

• 20%-40% bilateral MRS abnormality• Prelim evidence suggests higher likelihood of surgical

failure in TLE bilateral

Page 113: Neuroradiologyd2qrtshcpf0x30.cloudfront.net/nodes/58/Neuroradiology of Seizure... · •Transmit/receive coil only • No scans with body coil or receive only coils •Pulse generator

Normal Single Voxel Proton Spectra

Choline: 3.24 ppm Creatine: 3.02 ppm NAA: 2.02 ppm

Page 114: Neuroradiologyd2qrtshcpf0x30.cloudfront.net/nodes/58/Neuroradiology of Seizure... · •Transmit/receive coil only • No scans with body coil or receive only coils •Pulse generator

MTS

Page 115: Neuroradiologyd2qrtshcpf0x30.cloudfront.net/nodes/58/Neuroradiology of Seizure... · •Transmit/receive coil only • No scans with body coil or receive only coils •Pulse generator

MTS Spectroscopy

Right: Mild decrease NAA Left: Moderate decrease NAA Normal Control

Right Temporal Lobe Left Temporal Lobe

Page 116: Neuroradiologyd2qrtshcpf0x30.cloudfront.net/nodes/58/Neuroradiology of Seizure... · •Transmit/receive coil only • No scans with body coil or receive only coils •Pulse generator

FDG PET

• FDG – evaluates glucose metabolism

• TLE: interictal hypometabolism in >85%

• Useful if MRI + EEG are discordant or if normal MRI

• Not needed if EEG and MRI match

• Less useful in frontal lobe epilepsy

• Co-registration with MRI

FDG=Fludeoxyglucose (18F)

Page 117: Neuroradiologyd2qrtshcpf0x30.cloudfront.net/nodes/58/Neuroradiology of Seizure... · •Transmit/receive coil only • No scans with body coil or receive only coils •Pulse generator

Hybrid PET/MRI

• Currently typically co-register to MRI

• Hybrid PET-MRI – New combination modality• Initial experience: 29 patients with epilepsy surgery*

• 24/29 – No difference with PET/MRI

• 4 new MRI lesions with concordant PET

• 1 new PET abnormality

• All 5 new lesions were clinically significant

Shin HW, et al. Seizure. 2015.

Page 118: Neuroradiologyd2qrtshcpf0x30.cloudfront.net/nodes/58/Neuroradiology of Seizure... · •Transmit/receive coil only • No scans with body coil or receive only coils •Pulse generator

FDG PET: Temporal Lobe Epilepsy

Boca Radiology Group

Page 119: Neuroradiologyd2qrtshcpf0x30.cloudfront.net/nodes/58/Neuroradiology of Seizure... · •Transmit/receive coil only • No scans with body coil or receive only coils •Pulse generator

FDG PET: Temporal Lobe Epilepsy

New England PET Imaging

Page 120: Neuroradiologyd2qrtshcpf0x30.cloudfront.net/nodes/58/Neuroradiology of Seizure... · •Transmit/receive coil only • No scans with body coil or receive only coils •Pulse generator

Single-photon Emission Computerized Tomography (SPECT)

• Technetium 99m – Measures cerebral blood flow• Interictal – hypoperfusion

• Ictal – hyperperfusion – 90% localize in TLE

• Uses – similar to PET• Discordant MRI and EEG

• Problems• Not useful if multiple seizure onset

• False lateralization if delayed injection (>20 secs)

Page 121: Neuroradiologyd2qrtshcpf0x30.cloudfront.net/nodes/58/Neuroradiology of Seizure... · •Transmit/receive coil only • No scans with body coil or receive only coils •Pulse generator

Ictal SPECT

A. Interictal PET hypometabolismB. Ictal SPECT hyperperfusion

Page 122: Neuroradiologyd2qrtshcpf0x30.cloudfront.net/nodes/58/Neuroradiology of Seizure... · •Transmit/receive coil only • No scans with body coil or receive only coils •Pulse generator

SISCOM (Subtraction Ictal SPECT CO-registered to MRI)

• Sensitivity of ictal SPECT increased significantly when ictal and interictal images are subtracted

• Subtracted image superimposed on Hi-Res MRI

• Further increases sensitivity and specificity

• Surgical outcomes under study

Page 123: Neuroradiologyd2qrtshcpf0x30.cloudfront.net/nodes/58/Neuroradiology of Seizure... · •Transmit/receive coil only • No scans with body coil or receive only coils •Pulse generator

SISCOM

Mayo Foundation

Page 124: Neuroradiologyd2qrtshcpf0x30.cloudfront.net/nodes/58/Neuroradiology of Seizure... · •Transmit/receive coil only • No scans with body coil or receive only coils •Pulse generator

Functional MRI

• BOLD effect (Blood Oxygen Level Dependent): changes in venous blood oxygenation accompany changes in regional brain activity

• Cortical activation → increased blood flow >O2 utilization →increase in oxyhemoglobin

• T2 and T2*-weighted MRI are sensitive to changes in blood oxygenation (oxyhemoglobin vs. deoxyhemoglobin)

• Paramagnetic affects of oxyhemoglobin→ decreased signal on T2* MR sequence

• Subtle changes (<2% signal change at 1.5T, greater at 3T)• Statistical comparison of signal in rest and active paradigms

targeting specific brain regions• Allows detection of areas of brain activated by a specific task• Primary role → surgical localization

Page 125: Neuroradiologyd2qrtshcpf0x30.cloudfront.net/nodes/58/Neuroradiology of Seizure... · •Transmit/receive coil only • No scans with body coil or receive only coils •Pulse generator

Functional MRI – Paradigms

• Motor activation (finger tapping)

• Sensory activation

• Visual activity

• Auditory stimulation

• Language paradigms

• Memory tasks

Page 126: Neuroradiologyd2qrtshcpf0x30.cloudfront.net/nodes/58/Neuroradiology of Seizure... · •Transmit/receive coil only • No scans with body coil or receive only coils •Pulse generator

fMRI – On-Off Paradigm

Columbia fMRI

Page 127: Neuroradiologyd2qrtshcpf0x30.cloudfront.net/nodes/58/Neuroradiology of Seizure... · •Transmit/receive coil only • No scans with body coil or receive only coils •Pulse generator

Motor Activation

Page 128: Neuroradiologyd2qrtshcpf0x30.cloudfront.net/nodes/58/Neuroradiology of Seizure... · •Transmit/receive coil only • No scans with body coil or receive only coils •Pulse generator

Language Paradigms

Page 129: Neuroradiologyd2qrtshcpf0x30.cloudfront.net/nodes/58/Neuroradiology of Seizure... · •Transmit/receive coil only • No scans with body coil or receive only coils •Pulse generator

fMRI – Surgical Planning

Page 130: Neuroradiologyd2qrtshcpf0x30.cloudfront.net/nodes/58/Neuroradiology of Seizure... · •Transmit/receive coil only • No scans with body coil or receive only coils •Pulse generator

What is the source of the Mississippi River?

A. Lake Menominee

B. Lake Itasca

C. Lake Minnehaha

D. Lake Okeechobee

Page 131: Neuroradiologyd2qrtshcpf0x30.cloudfront.net/nodes/58/Neuroradiology of Seizure... · •Transmit/receive coil only • No scans with body coil or receive only coils •Pulse generator

Where Does Lake Itasca Get Its Name?

verITAS CAput“True Head”

of the Mississippi River

Page 132: Neuroradiologyd2qrtshcpf0x30.cloudfront.net/nodes/58/Neuroradiology of Seizure... · •Transmit/receive coil only • No scans with body coil or receive only coils •Pulse generator

Diffusion MRI

• Diffusion MRI is a specific pulse sequence that measures the micro-molecular translational motion of water molecules (Brownian motion) to obtain information on the microscopic behavior of the tissues

• Clinical applications• Stroke imaging

• Diffusion Tensor Imaging

• White Matter Tractography

Page 133: Neuroradiologyd2qrtshcpf0x30.cloudfront.net/nodes/58/Neuroradiology of Seizure... · •Transmit/receive coil only • No scans with body coil or receive only coils •Pulse generator

Diffusion MRI – Complex Math

Page 134: Neuroradiologyd2qrtshcpf0x30.cloudfront.net/nodes/58/Neuroradiology of Seizure... · •Transmit/receive coil only • No scans with body coil or receive only coils •Pulse generator

Diffusion MRI – Basics

• Gradients with equal amplitude but opposite polarity are applied over a given interval

• Gradients of sufficiently high amplitude make the sequence sensitive to motion at the microscopic level

• During the typical imaging time of 50 msec, the average water molecule diffuses 10 microns

• Stationary tissue will be dephased and rephased equally, whereas spins which have moved during the interval will suffer a net dephasing and signal loss

• Thus, protons that diffuse the farthest will have the greatest loss of signal

Page 135: Neuroradiologyd2qrtshcpf0x30.cloudfront.net/nodes/58/Neuroradiology of Seizure... · •Transmit/receive coil only • No scans with body coil or receive only coils •Pulse generator

Diffusion MRI in Stroke Imaging

• DWI is very sensitive to acute infarcts

• Revolutionized stroke imaging

• Hypothesis – as Na/K/ATPase pump fails, cells swell • Resultant restricted diffusion

• DWI – lightbulb bright infarcts• DWI drawback: both T2 + diffusion components

• ADC maps (apparent diffusion coeffecient) show the mean diffusion within each voxel (decreased diffusion → decreased signal)

Page 136: Neuroradiologyd2qrtshcpf0x30.cloudfront.net/nodes/58/Neuroradiology of Seizure... · •Transmit/receive coil only • No scans with body coil or receive only coils •Pulse generator

CT

• Acute onset

• Right sided weakness

• Right facial droop

• Slurred speech

Page 137: Neuroradiologyd2qrtshcpf0x30.cloudfront.net/nodes/58/Neuroradiology of Seizure... · •Transmit/receive coil only • No scans with body coil or receive only coils •Pulse generator

Diffusion vs Conventional MRI

FLAIR Diffusion

Page 138: Neuroradiologyd2qrtshcpf0x30.cloudfront.net/nodes/58/Neuroradiology of Seizure... · •Transmit/receive coil only • No scans with body coil or receive only coils •Pulse generator

Diffusion Tensor Imaging

• Diffusion imaging measures free motion of H2O

• Ex: restricted diffusion in acute infarcts

• Diffusion Tensor Imaging measures anisotropy (the degree of directionality to H2O motion)

• Allows mapping of white matter tracts (axons)

• Disrupted vs. displaced in tumor surgery planning

• Subtle cortical dysplasia or migrational anomaly

Page 139: Neuroradiologyd2qrtshcpf0x30.cloudfront.net/nodes/58/Neuroradiology of Seizure... · •Transmit/receive coil only • No scans with body coil or receive only coils •Pulse generator

In-vivo Water Diffusion

• Click to edit Master text styles– Second level

• Third level– Fourth level

» Fifth level

• Diffusion of water is hindered by cell membranes, myelin

• Diffusion of water• Greatest in CSF

• Reduced in gray matter and isotropic

• Reduced in white matter but anisotropic

Page 140: Neuroradiologyd2qrtshcpf0x30.cloudfront.net/nodes/58/Neuroradiology of Seizure... · •Transmit/receive coil only • No scans with body coil or receive only coils •Pulse generator

Diffusion in Biological Tissue

• Motion of water through tissue• Faster in some directions than others

Kleenex newspaper

• Anisotropy: diffusion rate depends on direction

isotropic anisotropic

Gordon Kindlmann - Scientific Computing and Imaging Institute, University of Utah

Page 141: Neuroradiologyd2qrtshcpf0x30.cloudfront.net/nodes/58/Neuroradiology of Seizure... · •Transmit/receive coil only • No scans with body coil or receive only coils •Pulse generator

Independent Verification

Page 142: Neuroradiologyd2qrtshcpf0x30.cloudfront.net/nodes/58/Neuroradiology of Seizure... · •Transmit/receive coil only • No scans with body coil or receive only coils •Pulse generator

Direction Encoded FA Maps

Page 143: Neuroradiologyd2qrtshcpf0x30.cloudfront.net/nodes/58/Neuroradiology of Seizure... · •Transmit/receive coil only • No scans with body coil or receive only coils •Pulse generator

White Matter Tractography: Fiber Mapping

Page 144: Neuroradiologyd2qrtshcpf0x30.cloudfront.net/nodes/58/Neuroradiology of Seizure... · •Transmit/receive coil only • No scans with body coil or receive only coils •Pulse generator

Corpus Callosum – Splenium Fibers

Page 145: Neuroradiologyd2qrtshcpf0x30.cloudfront.net/nodes/58/Neuroradiology of Seizure... · •Transmit/receive coil only • No scans with body coil or receive only coils •Pulse generator

Corticospinal Tract ROIs

Page 146: Neuroradiologyd2qrtshcpf0x30.cloudfront.net/nodes/58/Neuroradiology of Seizure... · •Transmit/receive coil only • No scans with body coil or receive only coils •Pulse generator

Corticospinal Tracts

Page 147: Neuroradiologyd2qrtshcpf0x30.cloudfront.net/nodes/58/Neuroradiology of Seizure... · •Transmit/receive coil only • No scans with body coil or receive only coils •Pulse generator

19-yo Male with HAGrade III Anaplastic Oligoastrocytoma

T2 T1 + Gad Cor T2

Page 148: Neuroradiologyd2qrtshcpf0x30.cloudfront.net/nodes/58/Neuroradiology of Seizure... · •Transmit/receive coil only • No scans with body coil or receive only coils •Pulse generator

DTI Fiber Mapping

Page 149: Neuroradiologyd2qrtshcpf0x30.cloudfront.net/nodes/58/Neuroradiology of Seizure... · •Transmit/receive coil only • No scans with body coil or receive only coils •Pulse generator

Left-Sided Weakness

Page 150: Neuroradiologyd2qrtshcpf0x30.cloudfront.net/nodes/58/Neuroradiology of Seizure... · •Transmit/receive coil only • No scans with body coil or receive only coils •Pulse generator

Bx: Grade III Anaplastic Astrocytoma

Page 151: Neuroradiologyd2qrtshcpf0x30.cloudfront.net/nodes/58/Neuroradiology of Seizure... · •Transmit/receive coil only • No scans with body coil or receive only coils •Pulse generator

Tractography: Tumor Surrounds Corticospinal Tracts

Page 152: Neuroradiologyd2qrtshcpf0x30.cloudfront.net/nodes/58/Neuroradiology of Seizure... · •Transmit/receive coil only • No scans with body coil or receive only coils •Pulse generator

Pre-op and Intra-op Integration

• MSI • Language

• Sensory

• Motor

• DTI/Fiber Mapping• Arcuate fasciculus

• Corticospinal tracts

• Optic radiations

• Intra-op MRI Integration

Page 153: Neuroradiologyd2qrtshcpf0x30.cloudfront.net/nodes/58/Neuroradiology of Seizure... · •Transmit/receive coil only • No scans with body coil or receive only coils •Pulse generator

Multimodal Surgical Planning with Intra-operative MRI

• 14-yo with seizure disorder

• Prior biopsy diagnosis: • Dysembryoneoplastic Neuroepithelial Tumor (DNET)

Page 154: Neuroradiologyd2qrtshcpf0x30.cloudfront.net/nodes/58/Neuroradiology of Seizure... · •Transmit/receive coil only • No scans with body coil or receive only coils •Pulse generator

Conventional MRI – DNET

Page 155: Neuroradiologyd2qrtshcpf0x30.cloudfront.net/nodes/58/Neuroradiology of Seizure... · •Transmit/receive coil only • No scans with body coil or receive only coils •Pulse generator

DNET Follow-up: Growth of Central Enhancing Nodule

12/19/07 2/26/08

Page 156: Neuroradiologyd2qrtshcpf0x30.cloudfront.net/nodes/58/Neuroradiology of Seizure... · •Transmit/receive coil only • No scans with body coil or receive only coils •Pulse generator

DTI/Fiber Mapping

Arcuate Fasciculus Corticospinal tracts

Page 157: Neuroradiologyd2qrtshcpf0x30.cloudfront.net/nodes/58/Neuroradiology of Seizure... · •Transmit/receive coil only • No scans with body coil or receive only coils •Pulse generator

Neuro-Navigation Integration

Page 158: Neuroradiologyd2qrtshcpf0x30.cloudfront.net/nodes/58/Neuroradiology of Seizure... · •Transmit/receive coil only • No scans with body coil or receive only coils •Pulse generator
Page 159: Neuroradiologyd2qrtshcpf0x30.cloudfront.net/nodes/58/Neuroradiology of Seizure... · •Transmit/receive coil only • No scans with body coil or receive only coils •Pulse generator

Intra-op Imaging and Stereotactic Guidance

Intra-op #1 Ax T2 Intra-op Final T2 Intra-op Final T1 + gad

90% tumor resection, 100% enhancing nodule resection, no deficits post-op

Page 160: Neuroradiologyd2qrtshcpf0x30.cloudfront.net/nodes/58/Neuroradiology of Seizure... · •Transmit/receive coil only • No scans with body coil or receive only coils •Pulse generator

Conclusions

• Imaging modalities in epilepsy• Anatomic – CT/MRI• Functional – fMRI, MRS, SPECT, PET, and MSI

• Imaging characteristics of common epilepsy pathology

• Methods of improved lesion detection • Subspecialized image interpretation• Dedicated seizure protocol • High resolution 3T MRI

• Multimodality integration • Pre-op planning • Intra-op navigation

Page 161: Neuroradiologyd2qrtshcpf0x30.cloudfront.net/nodes/58/Neuroradiology of Seizure... · •Transmit/receive coil only • No scans with body coil or receive only coils •Pulse generator
Page 162: Neuroradiologyd2qrtshcpf0x30.cloudfront.net/nodes/58/Neuroradiology of Seizure... · •Transmit/receive coil only • No scans with body coil or receive only coils •Pulse generator