Network IQ Training Manual Chapter 2 - Fibre Optic Cable Types
and Manufacturing
Slide 2
Optical FibreNetwork IQ Training Manual2 Fibre Optic Cable
Types and Manufacturing Loose Tube Cable (Indoor & Outdoor)
Tight-Buffered Cable (Indoor & Outdoor) Applications
Slide 3
Optical FibreNetwork IQ Training Manual3 Loose Tube Cable:
Fibre & Buffer Colouring Cables > 12 fibres have the same
colour code with stripes Colour code is according to EIA/TIA-598-A,
also referred to as Telcordia colour code Fibre No.Fibre coatColour
1BLUEBL 2ORANGEOR 3GREENGR 4BROWNBR 5SLATESL 6WHITEWH 7REDRD
8BLACKBK 9YELLOWYL 10VIOLETVI 11ROSERS 12AQUAAQ
Slide 4
Optical FibreNetwork IQ Training Manual4 More Colour Coding
Standards No.123456789101112 Colour No.123456789101112 Colour
No.123456789101112 Colour No.123456789101112 Colour Colour Code DIN
VDE 0888 Colour Code Swisscom Colour Code ISO Colour Code IEC
60794-2 For identification of more than twelve fibers is a ring
mark. The colours of the fibers are repeated
Slide 5
Optical FibreNetwork IQ Training Manual5 Fibre optic cable type
code acc. DIN VDE 0816
Slide 6
Optical FibreNetwork IQ Training Manual6 Cable Codes Corning
Example of Fiber description E9/125 0.36F3,5 + 0,22H18 E9 = Single
mode fiber 9 glass core diameter 125 = Cladding diameter 0,36 /
0,22 = Attenuation (db/km) F = At wavelength 1300 nm H = At
wavelength 1550nm 3,5 / 18 = Dispersions parameter at 1300nm
Remark: cabled parameters. Values on fibre data sheet are
better
Slide 7
Optical FibreNetwork IQ Training Manual7 Loose Tube Cable:
Fibre Buffering (up to 24 fibre) Optical Fibre Filling Compound
Optical Fibre Dry tube Swellable yarns Gel-free Buffer tube
Gel-filled Buffer tube Fibre bundle is a group of Optical fibres in
1 loose tube
Slide 8
Optical FibreNetwork IQ Training Manual8 Stranded Loose Tube
Cable : Fibre Buffering After Manufacturing Fibre Bundle Buffer
Tube Central Member Fibre Bundle Buffer Tube Central Member Buffer
Tube Contraction Fibre Bundle Buffer Tube Central Member Buffer
Tube Expansion Cross-section view of the loose tubes Side view of
the loose tubes
Slide 9
Optical FibreNetwork IQ Training Manual9 Central Member
Anti-Buckling Steel or Dielectric Stranded Loose Tube Cable:
Stranding Buffer Tubes with Fibres Central Member PE Sheet
Advantages SZ Stranding provides more flexibility Allows easy
midspan access Reduce the turn effects under pulling force
Slide 10
Optical FibreNetwork IQ Training Manual10 Stranded Loose Tube
Cable: Jacketing Jacket PE FRNC Core Protection Chemical Resistance
Abrasion Resistance Buffer Tubes with Fibres Central Member Dry
Waterblocking Material Strength Elements Jacket Tensile Strength
Elements Main Load Bearer Aramid and/or Fibre glass Yarns Dry
Waterblocking Material Armouring Corrugated Steel Tape Glass Yarn
Armouring
Slide 11
Optical FibreNetwork IQ Training Manual11 Central Tube Cable
Advantages High flexibility Low weight and fire rate Rodent
protection by glass yarn armour, metal-free Central tube = 3.0mm up
to 12 or 5.0mm up to 24 fibres, Swellable tape Jacket, PE Rip cord
Jacket PE FRNC Core Protection Chemical Resistance Abrasion
Resistance Tensile Strength Elements Main Load Bearer Aramid and/or
Fibre glass Yarns Dry Waterblocking Material Gel free buffer tubes
optional Armouring Corrugated Steel Tape Glass Yarn Armouring
Slide 12
Optical FibreNetwork IQ Training Manual12 For Indoor and
Outdoor Installations Halogen free & Flame retardent cable
construction Small and light weight design Various cable designs
for different applications Rodent protection UV resistant Swellable
elements for improved water penetration and faster installation
-Dry cable core -Gel-free MPC - Multi Purpose Cable
Slide 13
Optical FibreNetwork IQ Training Manual13 Duct Bank Dielectric
Armoured MPC Greater than 50 Feet Cable Applications Loose
Tube
Slide 14
Optical FibreNetwork IQ Training Manual14 Thermoplastic Coating
900 m Tight Buffered Cable Buffering Coating Versions: TB Easy
Strip, FRNC, 1.5m strip length, used in pigtails TB3 Standard,
FRNC, 10cm strip length, used in jumpers, i-MIC Optica l Fibre 250
m Coating
Slide 15
Optical FibreNetwork IQ Training Manual15 Fibre Cable Jacket
Colouring Indoor Aqua - OM3, OM4 Orange - OM1, OM2 Yellow - OS1,
OS2 Fibre Tight Buffer Strength Elements Coated Central Member
Outer Jacket 12-Fibre MIC Multifibre Indoor Cable FRNC or PVC
Sheath 2-24 Fibre
Slide 16
Optical FibreNetwork IQ Training Manual16 Multi-Fibre Cable:
MPC Cable (TB3) (up to 24 fibre) A-VQ (BN) H In-/Outdoor Cable
Strength elements/aramid yarn Tight Buffered Fibre Glass yarn
armour Swellable elements (water blocking) LSZH Inner jacket Rip
cord LSZH Outerjacket
Slide 17
Optical FibreNetwork IQ Training Manual17 Fibre Kevlar
Thermoplastic Buffer Outer Jacket 1-Fibre, 2-Fibre Basic Cable Unit
Simplex Cable Duplex Cable (Zipcord) Used in standard patch cords
Simplex Available in: 2.0mm 2.8mm Duplex Available in: 2x1.8mm (700
m coating) 2x2.0mm 2x2.8mm
Slide 18
Optical FibreNetwork IQ Training Manual18 Break out Cable FRNC
Jacket Dielectric Central Member Ripcord 1-Fibre Basic Unit FRNC
Overcoat
Slide 19
Optical FibreNetwork IQ Training Manual19 Cable Applications
Tight Buffered Cables MIC or Breakout Cable MIC or Breakout
Cable2-fibre Zipcord
Slide 20
Optical FibreNetwork IQ Training Manual20 Flame Retardant
Cables: European Flame and Smoke Tests IEC-StandardTest name IEC
60332Tests on electric and optical fibre cables under fire
conditions IEC 60332-1Test for vertical flame propagation for a
single insulated wire or cable IEC 60332-2Test for vertical flame
propagation for a single small insulated wire or cable IEC
60332-3Test for vertical flame spread of vertically-mounted bunched
wires or cables IEC 61034Measurement of smoke density of cables
burning under defined conditions IEC 60754-1Test on gases evolved
during combustion of materials from cables - Part 1: Determination
of the amount of halogen acid gas IEC 60754-2 Test on gases evolved
during combustion of electric cables - Part 2: Determination of
degree of acidity of gases evolved during the combustion of
materials taken from electric cables by measuring pH and
conductivity 0H or ZH NC FR LS
Slide 21
Optical FibreNetwork IQ Training Manual21 Force = Mass x
Acceleration [N] = [Kg] x 9.81[m/sec 2 ] Reference: 1 pound = 4.45N
Tensile Strength (IEC 60794-1-2-E1) FO cable is pulled by a tensile
force measured in Newton Ex: 2700 N Crush Resistance (IEC
60794-1-2-E3) FO Cable is tested using a plate which applies a
crushing load measured in Newton Ex: 3000 N/10cm (linear) Bending
Radius (IEC 60794-1-2-E11 A) FO Cable is bent to meet its specified
bending radius Ex: Generally, 15xOD during installation and 10x OD
during operation OD = outer diameter of cable, non-armoured cable
Requirement: Mechanical Tests are conducted for 1 minute or more No
fibre break or Attenuation more than 0.05 db Mechanical
Characteristics of Fibre Optic Cable
Slide 22
Optical FibreNetwork IQ Training Manual22 Cont. mechanical
characteristics of FO-Cable Tensile TestCrush Resistance Test
Bending Radius Test
Slide 23
Optical FibreNetwork IQ Training Manual23 Water Penetration
(IEC 60794-1-2-F5) FO cable prevents water from penetrating inside
the cable and inside the loose tubes Temperature Cycle (IEC
60794-1-2-F1) FO Cable can be exposed to low temperature or high
temperature without any material deformation or high attenuation
more than 0.05 db Ex: -40C to +70C Environmental Characteristics of
FO Cable 3 meter sample Water height 1 meter 24 hours No water
penetrate to the sealed side of the cable Requirement: Heat Chamber
-40C to +70C Dwell time 6 hour Measurement at 1310 nm & 1550 nm
Max Att. 0.1 db/km
Slide 24
Optical FibreNetwork IQ Training Manual24 Cable Summary Two
main design options for fibre cables: Loose Tube (250um coated
fibres) Tight Buffered (900um coated fibres) Loose Tube typically
outdoor application Loose tube isolates fibre from external strain
250um easy to splice Use fan out tube if direct termination with
connectors Tight buffered cables typically indoor application 900um
allows direct termination with connectors Telcordia colour scheme
is standard Corning code; others available