Network, Cable & Electrical Testing ON-LINE www.rssingapore.com 93 OM = Order Multiple 2239 Electrical Installation Software 2239 Megger Electrical Installation Test Equipment 2239 ISO-TECH Electrical Installation Test Equipment 2242 Martindale Electrical Installation Test Equipment 2243 16th Edition Test Equipment 2244 InstalTest Installation Testers 2245 SANWA Insulation Testers 2245 Chauvin Arnoux Electrical Installation Test Equipment 2246 Fluke Electrical Installation Test Equipment 2246 Earth Testing 2246 Clampmeters 2249 Power Measurement 2258 Energy Monitoring 2262 Portable Appliance Testing 2262 92 Lab Equipment, Environmental Monitoring & Calibration 2182 91 Bench Power Supplies 2172 94 Inspection & Mechanical Measurement 2283 Test & Measurement Network, Cable & Electrical Testing - contents 95 Multimeters 2310 96 Oscilloscopes 2340 97 Logic Analysers & Signal Generation 2353 98 Test Leads & Accessories 2361 Flash/Hi-Pot Insulation Testers 2266 Cable Fault Locators 2267 Cable and Metal Detectors 2268 Mains Socket Testers 2269 Phase Rotation Testers 2270 Voltage Level Indicators 2271 Mains Voltage Indicators 1778 Automotive Voltage Indicators 2273 Magnetic Field Indicators 2273 Cable Test Equipment 2273 Network Test Equipment 2278 Telecom Test Equipment 2279 2236 www.nguyenxuong.com
45
Embed
Network, Cable & Electrical Testing - contents COMPONENTS/RS... · 2016-11-19 · Network, Cable & Electrical Testing ON-LINE 93 OM = Order Multiple a New product to range MIT230
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
with high performance circuitry for fast data processing and
rapid display of readings. 200mA short-circuit current in
accordance with BS7671 regulations continuity test.
250V, 500V, & 1000V insulation test voltages
200 mA continuity short circuit current, fuse protected to comply
with BS7671 Wiring Regulations
Backlit display
Live circuit audible & visible warning
Lock-down button
Ohms zero-adjust to null out test lead resistance
Complies with safety standard EN610101-1 CAT III 300V
Tests to BS7671 413-04-04, 713-02, 713-03, 713-06, 713-08
Large backlit 3¾ digit, 4000 count LCD with analogue
bargraph
Insulation resistance to 4000MΩ autoranging
250V, 500V & 1000V insulation test voltages
Continuity to 40Ω, 200mA test current
Low battery warning
Continuity beeper
Lock and hold facility
Auto power off
Meets the requirements of EN61557 and BS7671 / wiring
regulations
Safety to EN61010-1 600V CAT III
Digital continuity and insulation tester
250/500/1000V insulation test ranges (1mA)
20/200/2000 Ohm continuity ranges with 200mA test
current
Auto null
Bar graph indication of test voltage
Live circuit warning
Protects against accidental connection to live circuit
Supplied with: Test leads, crocodile clips, instruction manual and 6 AA alkaline batteries.
Supplied with: Test leads and batteries.
Two RCD testers that comply with
EN61557 for testing, measuring or
monitoring of protective measures.
Insulation Test Ranges Open CircuitVoltage Output
4 to 9Vdc
DC Test Voltage 250V, 500V, 1000V Short CircuitCurrent Output
200mA min
Measuring Range(Mid Full Scale )
0 to 100MΩ (1MΩ)0 to 200MΩ (2MΩ)0 to 400MΩ (4MΩ)
Accuracy ± 3% of scale length
Output Current 1mAdc General
Accuracy 5% Withstand Voltage 5000Vac for 1 minute between electricalcircuit and case
Continuity Test Ranges Dimensions (H x Wx D)
175 x 115 x 86mm
Measuring Ranges0 to 2Ω, 0 to 20Ω Weight 640g
General
Power 12 Vdc (8 x 1.5 V AA)
Safety EN61010-1 600 V CAT III
Memory (Test results) Data hold function
Dimensions 77 x 140 x 190 mm
Weight 900g
AC Voltage
Voltage Range 0 → 600 V
Voltage Resolution 1 V
Voltage Accuracy ±(1.5 % rdg + 3 digits)
Overload Protection 750 Vrms
Insulation
Insulation Resistance Impedance Range 0 - 4000 MΩ
Resolution 1kΩ
Accuracy ±(3% rdg + 3 digits)
Output Short Circuit current 1.7 mA Max.
Continuity
Range 400Ω
Accuracy ±(1% rdg + 5 digits)
Overload protection 220Vrms
Continuity Beeper
Resolution 0.1Ω
Operation resistance <40Ω
Overload protection 220Vrms
Tests 30mA, 100mA, 300mA and 500mA rated RCDs
1/2x I, I, 5x I tests standard, DC and selective RCDs
0° or 180° polarity tests on all RCDs
Selective breakers have a time delay in tripping. When
selected, trip test times are extended and a 30s delay is
allowed between the measurement of the fault voltage
and the application of the test current
Selectable touch voltage inhibit and touch voltage display
on the analogue bargraph
Automatic capacitive circuit discharge on release of test button
Lock-down test button for continuous operation
Complies with safety standard EN61010-1 CAT III 300V
Description Stock no. Price per OM S$ S$ S$
IIT1601 697-3724S unit 1+ 636·00
PFC Display up to 20kA
Voltage and frequency measurement
110Vac systems including 110V centre tap to earth (55V phase to earth) can be tested on the
secondary winding.
IP54 Weatherproof case
Optional 10A fused 2 wired test leads and crocodile clip set
Complies with IEC61010-1 300V CATIV safety standard and meets EN61557
300Vac (25 to 45Hz) voltage measurement range
Clear 20mm high digit LCD display with analogue arc bargraph
Tough rubber armoured case with self-contained display cover that locks away underneath the
instrument during use
Safety input terminal interlock - prevents unsafe connection of test leads
Safety lock-out prevents the test from operating when the circuit voltage is >300V
Stock no. Price per OM S$ S$ S$
530-5681S unit 1+ 460·00
RCDT320 model additional features
Note: RS is an authorised Megger distributor. Purchased though RS this product is eligible for the
Megger extended 3 Year warranty
Supplied with: Test lead set with crocodile clips, mains socket test lead, 8 AA alkaline batteries, hard
carry case and instructions.
10mA/1A RCD extended test capability
Backlit display and range selection ideal for low light environments
Ramp Test measures & displays the actual trip current of an RCD. Ideal for diagnosing nuisance
tripping of RCDs
Auto testing allows remote testing from the RCD under test. The RCDT320 will automatically
perform a 1/2 I, I and 5I test at both 0°and 180°. When the RCD trips the user resets it and the tester
proceeds to the next test automatically. All results are displayed at the end of the test
25 to 450Hz Frequency measurement range
Optional 2-wire test leads supplied
Voltage measurement
(ac only) 50V to 440V Accuracy ±2% ±1V Range 25Hz to 99.99Hz Accuracy ±0.1Hz A warning will be shown if applied voltage exceeds 440VDamage will occur if applied voltage exceeds 600Vrms Loop testing
No-trip loop and high current loop test
Source voltage LTW315: 100V to 280V (50Hz)LTW325: 50V to 440V (50Hz)
Display range 0.01Ω to 2000ΩAccuracy ±5% ±0.03ΩNominal test current No-Trip loop test 15 mA (at nominal 230Vac supply) High current loop test 4 A (at
nominal 230 Vac supply) Operational range 0.30Ω to 1000ΩProspective Fault Current (PFC)
Prospective fault current Measured Source Voltage / Loop resistance Maximum range 40 kA; accuracy is derived from loop test and voltage measurement. Safety
EN61010 Designed to EN61010-1 ed2 2001-02 Designed for 300 volts to Earth Category IV, withPhase to Phase voltages to 440 Volts; Fuse protected to 600 volts rms ac
EN61557 Complies with the following parts of EN61557, Electrical safety in low voltage systemsup to 1000V ac and 1500V dc- Equipment for testing, measuring or monitoring ofprotective measures: Part1-General Requirements; Part3-Loop resistance
Power supply
Battery 8 x 1.5V cells IEC LR6 type (AA alkaline) Rechargeable 8 x 1.2V NiCd or NiMH cells Battery life 2000 consecutive tests Mechanical
Weight 1000g ±10% excluding test leads Dimensions 203 x 148 x 78 mm
3-phase safe - Meets the requirements of BSEN 61010-1 for safe connection to a 440V Installation
Category III supply (300V phase to Earth)
Weatherproof to IP54
Dimensions (WxHxD): 190 x 75 x 140mm; Weight 980g
Description Stock no. Price per OM S$ S$ S$
LTW315 198-435S unit 1+ 910·00
LTW325 198-457S unit 1+ 1070·00
Note: RS is an authorised Megger distributor. Purchased though RS this product is eligible for the
Megger extended 3 Year warranty
Supplied with: Instructions, Mains plug test leads, 8 AA alkaline batteries, neck strap.
Many more leading brands from over 2,500 suppliers available online
Triple Voltage Insulation andContinuity Tester MartindaleIN2102
Fused Test Lead Set for Loop &RCD Testers
IRT2310 RCD Tester with DCtest
IRT1900 Digital RCD Tester
IPT2300 PSC Loop ImpedanceTester with Anti-RCD TripFeature
18 RCD test current ranges
Tests RCDs and DC sensitive breakers 1⁄2 x, 1x, and 5x device ratings
Constant current control circuitry permits accurate readings
even when mains fluctuates by ±10% at 240V
0° and 180° phase selection
LED status lights for easy reading in dimly lit areas
LED indication of correct wiring status
Excessive overvoltage warning with lockout
Tripping time resolution 1ms
Complies with safety standard EN610101-1 CAT III 300V
A fully specified insulation tester with 250V, 500V & 1000V insulation tests that
provides accurate testing and is ideal for single handed operation. The output test
voltage is automatically displayed during testing and confirms that the desired test
voltage is being developed. The automatic zero adjust removes the resistance of
the leads and the test button can be set to be either latching, to give a permanent
output, or "press to test".
Custom microprocessor for highest accuracy and
reliability
3 LED’s for checking correct wiring status
0° and 180° phase angle switch permits quick tests and
consistent readings
Visual indication of reversed phase & neutral wiring at
socket
Digital read out of tripping time
20/200/2000Ω loop impedance test ranges
PSC measurement to 20kA
Anti trip technology allows 15mA low current loop testing
without bypassing all RCD types
25A high current test for fast tests in noisy environments
and where tripping RCDs is not a consideration.
Fully protected against phase to phase connection
Earth probe for testing exposed metalwork
Colour coded LEDs for instant check of correct wiring
status
Complies with BS 7671 wiring regulations
Complies with safety standard EN610101-1 CAT III 300V
This auxiliary test lead is designed for use with a wide range of earth loop
impedance testers and RCD testers. Both the red and black probes are
fused to enhance the safety of the user. A pair of shrouded safety croc-clips
are also available.
Supplied with: Test leads
Note: Colour may differ from that shown.
Description Stock no. Price per OM S$ S$ S$
Fused test leads 216-839 unit 1+ 74·50
Shrouded Crocodile Clips 218-100 unit 1+ 20·10
250V,500V & 1000V insulation test voltages
200mA continuity test current with buzzer below 30Ω
5,000 count backlit digital display with analogue bargraph
Displays test voltage
Auto HOLD of test readings
Automatic discharge of circuit under test
Live circuit audible and visible warning
“Press to test” or latching test button mode to give a permanent output on
Note: Colour may differ from that shown.
Tests to: BS7671: 413-04-04, 713-02, 713-03, 713-04, 713-06, 713-08-01
Supplied with: BS1363 mains socket test lead, distribution board fused test leads with earth lead
crocodile clip, instruction manual test lead pouch and 8 x AA alkaline batteries.
Supplied with: carrying strap, mains leads for BS1363 mains socket outlets, test lead pouch and
instruction booklet.
General Fault condition setting x1/2, x1 & x5 Safety EN61557; BS7671, EN61010-1 300V CAT III Fault trip time 2000ms, 40ms (x5) Display Type LCD Low set resolution 1ms (x1/2, x1) & 0.1ms (x5) Dimensions 70 x 130 x 180mm Trip time accuracy ± (1% rdg + Dgts) Weight 800g Operating voltage 230V ±10%, 50/60Hz Specification Withstand voltage 3000V AC for 1 minute Tripping current 10 / 20 / 30 / 100 / 300 / 500mA Operating temperature & humidity 0 to 40°C below 80% RH
insulation test
Automatic zero adjust removes the resistance of the test leads
Complies with BS EN 61557 (17th Edition) UK and international standards
Complies with EN61010 CAT III 600V
Supplied with: 6 AA alkaline batteries, instructions, carry case, test leads and crocodile clips.
Supplied with: Test leads, crocodile clips, instruction manual and 6 AA alkaline batteries.
Test current settings 10, 20, 30, 100, 300,500 mA
Test current Factors 1/2X, 1X, 5X, DC
Fault Trip Current Duration 2000ms (1/2X, 1X, DC)50ms (5X)
Rated system voltage 230V +10% , -15%; 50Hz
Trip time accuracy ±(0.6% + 4 digits)
Safety Rating EN61010-1 CAT III 300V
Stock no. Price per OM S$ S$ S$
697-3777S unit 1+ 490·00
Range Test Current Accuracy
Loop Normal 0 → 20Ω 25A for 10ms 3% rdg ±4 digits
Loop Normal 0 → 200Ω 2.3A for 40ms 3% rdg ±4 digits
Loop Normal 0 → 2000Ω 15mA for 360ms 3% rdg ±4 digits
Loop Anti-Trip 0 → 20Ω P-N 25AN-E 15mA or less. *resistance P-N must be = 20Ω
3% rdg ±6 digits
Loop Anti-Trip 0 → 200Ω P-N 25AN-E 15mA or less. *resistance P-N must be = 20Ω
3% rdg ±6 digits
PSC Normal 0 → 20kA 25A Determined by loop accuracy
PSC Normal 0 → 2000A 2.5A Determined by loop accuracy
PSC Normal 0 → 200A 2.3A Determined by loop accuracy
PSC Anti-Trip 0 → 20kA P-N 25AN-E 15mA or less. *resistance P-N must be = 20Ω
Determined by loop accuracy
PSC Anti-Trip 0 → 2000A P-N 25AN-E 15mA or less. *resistance P-N must be = 20Ω
Determined by loop accuracy
PSC Anti-Trip 0 → 200A P-N 25AN-E 15mA or less. *resistance P-N must be = 20Ω
Determined by loop accuracy
Voltage Measurement 100 → 300V 50Hz - 2% ±4 digits
Insulation Test Ranges Accuracy 0 to 20Ω ±(1.5% rdg +5 dgt)0 to 200Ω & 0 to 2000Ω ±(1.5%rdg +5 dgt)
DC Test Voltage 250V; 500V; 1000V General
Measuring Ranges 20MΩ 200MΩ 2000MΩ Withstand Voltage 5000Vac for 1 minute betweenelectrical circuit and case
Output Voltage on OpenCircuit
250Vdc ±10%500Vdc ±10%1000Vdc ±10%
Overload Protection
Output Current 1mAdc Safety Standard EN61010-1 CAT III 300V Output Short Circuit Current 1.3mA approx Dimensions (H x W x D) 175 x 115 x 86mm Accuracy 20MΩ / 200MΩ ± (1.5% rdg +5
dgt)2000MΩ ± (10% rdg +3 dgt)
Weight 640g
Continuity Test Ranges
Measuring Ranges Short Circuit Output Current 200mA min
Stock no. Price per OM S$ S$ S$
712-7036S unit 1+ 544·00
Stock no. Price per OM S$ S$ S$
712-7032S unit 1+ 740·00
IN2102 Accuracy ±3% ± 5 digit Display Digital Short circuit test current >200 mA Insulation Resistance Ranges 4/40/400/1000MΩ (250 V)
4/40/400/4000 MΩ (500 V)4/40/400/5000 MΩ (1000 V)
Resistance Range 0.1Ω to 1999 kΩ
Accuracy ±3% ±5 digit Accuracy ±3% ±5 digit Test voltage 250 V, 500 V, 1000 Vdc Test voltage 4 Vdc nom. Short circuit current <1.5 mA Voltage test range 0 → 600 V ac/dc Continuity Range 40Ω Accuracy ±3% ± 5digit
Max display 999 Counts (1000 counts only at 1000GΩ) 630 Counts
Current consumption Approx.1000mA (During measurement) 25mA approx.
Withstand voltage 5320V AC for 5 seconds
Power supply DC 12V: 1.5V R14 × 8
Dimensions 205(L) × 152(W) × 94(D) mm, weight approx. 1.8kg
Insulation Resistance Ranges Output Voltage 7 - 12V DC Test Voltage 250V/500V/1000V Measuring Current 200mA DC min Measuring Ranges 20MΩ/200MΩ/2000MΩ AC Voltage Range 0 - 600V AC Output Voltage on Open Circuit Rated Test Voltage +20%, -0% General Specifications
Nominal Current 1mA DC min Power Source R6P (AA) (1.5V) x 8 Output Short Circuit Current 1.5mA DC approx. Dimensions (mm) 185 (L) 167 (W) 89 (D) Continuity Test Ranges Weight 990g approx. Measuring Ranges 20MΩ/200MΩ/2000MΩ
Stock no. Price per OM S$ S$ S$
627-8760 unit 1+ 1000·00
Stock no. Price per OM S$ S$ S$
466-6014 unit 1+ 540·00
Wiring connection check LEDs: Immediate indication if
wiring of circuit under test is correct
Overheat Protection:Rapid detection of overheating of
internal circuitry, display of warning signal to user and
automatic halting of measurement
Supply Voltage Indication: Can display supply voltage
value in loop impedance mode
Low Current Loop Impedance Test: Short duration low
test current will prevent tripping of many passive RCDs
Phase Angle Selection: Selection of test current from +ve
or -ve half cycle of waveform can prevent tripping of
polarized type RCDs
Loop Impedance Ranges (Z reading) 20/200/2000Ω 1000ms: x1/2, x1, DC Max test current on Loop ranges 3A (20Ω) / 15mA (200
and 2000Ω) 200ms: x5, DC (500mA), & x1
(1000mA) PSC / Earth Fault Current Ranges 200/2000A/20kA RCD Ramp Test From 20% to 110% of
IΔn (AC type) RCD Test AC Type (Standard and Selective) Contact Voltage Reading (RCD) 100.0V x1/2: 10, 30, 100, 300, 500,
1000mA Working Voltage for Loop Tests 20Ω: 230V+10%-15%
x1: 10, 30, 100, 300, 500,1000mA
200/2000Ω:230V+10%-15% and400V+10%-15%
x5: 10, 30, 100mA Working Voltage for RCD Tests 230V+10%-15% Auto Ramp: 10, 30, 100, 300, 500mAVoltage Tests 100 ∼ 260V RCD Test A Type (Standard andSelective)
Timer measurements over long periods (CA6525 only)
IP54 ingress protection
3 range tester for maximum versatility
MΩ measuring switch allows one-shot and continuous
measurements
dc voltages up to 60V can be measured
ac voltages up to 600V can be measured
Handy neck strap for hands free operation
IEC 1010-1 CATIII 600V
JIS C 1302-1994
Description Stock no. Price per OM S$ S$ S$
MG500 543-302 unit 1+ 450·00
MG1000 543-308 unit 1+ 495·00
The 3-in-1 multi-function tester, installation
tester and pass/fail tester
MΩ measuring switch allows one-shot and continuous
measurements
dc voltages up to 60V can be measured
ac voltages up to 600V can be measured
Handy neck strap for hands free operation
IEC 1010-1 CATIII 600V
JIS C 1302-1994
BestAccuracy
± (2% + 0 to 4digit)
Battery Silver OxideCell SR44 x 2
Resolution 0.001 MΩ Size 117(H) x 76(W)x 18(D) mm
Display 4000 Weight 125g
MG Series Testers
Supplied with: 6 x LR6 batteries, "Hands-free" shoulder bag and test leads.
Function Range 250V Insulation Test 0.05 to 500MΩ
1000V Insulation Test 1 to 2000MΩ ac Voltage 0 to 600V500V Insulation Test 0.5 to 1000MΩ dc Voltage 0 to 60V
Function Range ac Voltage 0 to 600V500V Insulation Test DM 508S 0.5 to 1000MΩ dc Voltage 0 to 60V500V Insulation Test DM 5 to 2000MΩ Battery life DM 508S 5.5 hours1008S Battery life DM 1008S 4 hours
Automatic calculation of Polarization Index and Dielectric Absorption Ratio
(1507 only)
Compare (pass/fail) function (1507 only)
Remote test probe
Live circuit detection prevents insulation test if >30V is present
Auto-discharge of capacitive voltage
Voltage range 0.1 to 600Vac/dc
Continuity 200mA
Resistance 0.01 to 20kΩ
Multifunction installation testers to verify the safety of
electrical installations in industrial, commercial and
domestic applications
Meet the requirements of IEC 60364, HD 384 and BS 7671
17th Edition wiring regulations
Large illuminated display with exceptionally wide viewing
angle
Rugged: withstand a one meter drop for demanding field
use
Selective testing with no disconnection of ground conductor (using one clamp)
Stake-less testing with no disconnection of ground conductor and no ground stakes for quick
ground loop testing using 2 clamps
Resistance measurement without current or voltage spikes for rapid testing of pole mounted
transformers.
Earth impedance measurement at 55 Hz
Automatic frequency control (94, 105, 111, 128 Hz) selects a measuring frequency to minimise the
effect of existing interference
Selectable test voltage20/48V enables safe testing where livestock may be present
IP56 splash-proof case
Programmable GO / NO-GO limits, settings
Continuity with buzzer
All inputs are protected to EN 61010-1, CAT III 500V
Battery indicator, and battery test function
Weight 1.2kg
Supplied with: Remote probe, test leads, test probes, alligator clips, holster, user
documentation.
Supplied with: 2 test leads, 4 earth ground stakes, 3 cable reels with wire (2 x 25m, 1 x 50m), clamp
set for selective / stake-less (one inducing, one sensing), batteries, manual, carrying case.
AC/DC Voltage Accuracy Short circuit current 1mA nominal Range accuracy 600.0V General Specifications
Resolution accuracy 0.1V Max. voltage applied to any terminal 600Vac rms ordc
50Hz to 400Hz +/- (% of Rdg + Digits)accuracy
+/-(2% + 3) Operating temperature -20 °C → +55°C
Overload protection 600V rms or dc Dimensions H203 x W50 xD100mm
Earth Bond Resistance Measurement Weight 550g Range accuracy +/-(1.5% + 3) Overload protection 2V rms or dc Height (mm) 203 Insulation Specifications Width (mm) 50 Test voltages 1507; 50V, 100V,
250V, 500V,1000V1503: 500V,1000V
Depth (mm) 100
Test voltage accuracy +20%, -0% Weight 0.5 kg
Support Accessories:
Display 4 digit 3000 count LCD Accuracy ±7% of range +2 digits 3 & 4- pole measuringrange
0.001Ω to 300kΩ Operating errors ±10% of range +5 digits
Accuracy ±2% of range +2 digits Test current 250mA a.c. short circuit Operating errors ±5% of range +5 digits Test voltage 20V / 48V a.c. Selective rmeasuringranges
0.001Ω to 30kΩ Battery life Typical 3000 measurements(RE+RH ≤ 1kΩ)Typical 6000 measurements(RE+RH ≤ 10kΩ)
Accuracy ±7% of range +2 digits Dimensions (W x H x D) 250 x 133 x 187mm Operating errors ±10% of range +5 digits Weight 1.1 kg including batteries
5.5 kg including accessories andbatteries in carrying case
Stake-less measuringrange
0.001Ω to 30kΩ Working temp. range -10 °C → +50 °C
TP165X remote probe Slim line remote probe with built-in test button to facilitate one-handed
measurements on Fluke 1650 & 1650B series installation testers see 468-0616
TL165X fused test lead set see 468-1063
Earth Spike Test kit: For earth resistance testing on the Fluke 1653 & 1653B using the 3 wire
connection method and auxiliary earth spikes.
Contains Auxiliary earth probes, test connection leads and crocodile clips, purpose-made carry
case . See 468-0600
FVF-SC2 FlukeView� documenting software: for documenting, storage and analysis of
measurements, from the Fluke 1653B and 1654B. Allows editing of an existing form or creation of a
new form to customize the report to individual needs
Contains software on CD-ROM and USB/ IR interface cable See 385-0599
Lead Compensation No YES Resistance
Range (Ω) No 0 to 399.9k Resolution (Ω) No 0.1/1/10/100 Accuracy No ±(3% +2digts) Voltage
Range (V) 0 - 600 ac/dc 0 - 600 ac/dc Resolution 0.1/1V 0.1/1V Accuracy ±(3% + 1digt) ±(3% + 1digt) Alarm No YES Timer No 0 to 15 mins Size (WxHxD) & Weight 108 x 211 x 60mm, 835g 108 x 211 x 60mm, 835g Safety IEC 61010-1 CAT III 600V IEC 61010-1 CAT III 600V
Description Stock no. Price per OM S$ S$ S$
1503 518-5998S unit 1+ 737·00
1507 518-6008S unit 1+ 858·00
Description Stock no. Price per OM S$ S$ S$
CA6521 346-7355S unit 1+ 680·00
CA6525 346-7377S unit 1+ 870·00
Contact RS for calibration requirements
Stock no. Price per OM S$ S$ S$
645-1820 unit 1+ 6133·00
Note: 6AA Alkaline are originally supplied, 1.2V NiMh are also suitable; all stored data will be lost if
batteries are not replaced within approximately 1 minute for model 1653B and 1654B
RS is currently unable to supply replacement fuses for these products.
Supplied with: (All models): detachable leads (TP165X & TL165X), 6 AA cell batteries, a durable
hard carrying case, padded carrying strap, mains test cord, quick reference guide.
This kit provides all the necessary equipment to enable
earth testing to be carried out in conjunction with a 3 or 4
pole earth tester
4 pole earth tester with rechargeable batteries for measuring
soil resistivity and resistance of earth rods and associated
installations. Supplied in a hard carry case together with
auxiliary stakes and cables.
4 pole earth tester for measuring soil resistivity and resistance
of earth rods and associated installations. Supplied in a hard
carry case together with auxiliary stakes and cables.,An ICLAMP
selective clamp is available separately, and when used with the
DET4TC allows the testing of an earth rod without the need for
disconnection from the system.,A VCLAMP is also available
separately, which when used in conjunction with ICLAMP
allows stakeless measurements to be made in situations where
driving auxiliary stakes is not practical.
Large backlit LCD display, controlled by 2-axis paddle for ease of use.
Results can then be stored together with any relevant notes, for later
download to a PC.
Resistance range 0.01 to 20,000 ohms auto ranging
Choice of 2, 3 or 4 terminal measurements
Simple one button operation
Superior noise rejection to 40V pk-pk
Results in less than 3 seconds
Lightweight, easily portable and easy to use
4-wire measurement to null out lead resistance
Auto mode. Connection of handspikes supplied automatically starts
test without the need to press test button
Auto current reversal cancels out standing EMFs
User selectable high and low limits
Memory for up to 700 sets of results complete with notes of up to 200
characters
Keypad for extra data entry
Fuse protected to 600V
NiMH battery reduces weight
Contents:
Heavy duty low resistance ohmmeter combining
rugged construction with accuracy and ease of
use. It features an internal rechargeable battery
Resistance range 0.01 to 20k ohms auto ranging
Choice of 2, 3 or 4 terminal measurements
Simple one button operation
Superior noise rejection to 40V pk-pk
Measures earth voltage 0 – 100V
Automatic P spike and C spike check
Clamp input for no-disconnect testing (required ICLAMP)
Clamp inputs for stakeless testing (required ICLAMP and
Tool bag
One 2.5lb (1.1kg) hammer
Four galvanised steel spikes
30m and 50m lengths of cable on a cable-winder
3m leads complete with connectors and clips
Measures earth voltage 0 – 100V
Automatic P spike and C spike check
Clamp input for no-disconnect testing (required ICLAMP)
Clamp inputs for stakeless testing (required ICLAMP and VCLAMP)
Earth current range (requires ICLAMP)
and can also operate from a mains supply, even if the battery is
completely flat
250mW power limit (with optional override) to avoid heating the test sample
VCLAMP)
Earth current range (requires ICLAMP)
Stock no. Price per OM S$ S$ S$
204-612 unit 1+ 580·00
Supplied with: 2 x spikes, mains charger, car charger and NiMH battery.
Standards: EN61010-1 CAT IV 100V
Standards: EN61010-1 CAT IV 100V
2 high power ( up to 25W) ranges ideal for inductive applications,
and where heating a potential weakness is desirable
7 low power output ranges limited to 0.25W to avoid heating the
test piece and to extend battery life.
Rechargeable battery or line power supply, continuous operation,
even with dead battery
10 A for 60 seconds, less time waiting to cool, great for charging
inductance
High input protection to 600 V, inadvertent connection to line or
UPS voltage will not blow a fuse
Heavy duty case: IP 65 lid closed, IP54 operational (battery operation only)
Large backlit LCD is clear and easy to read in all lighting conditions.
Rotary switch selects one of five test modes, including auto start on connection, giving ease of use
1·9999Ω 100μΩ ±0·2%±0·2mΩ 20mV 10mA
19·999Ω 1mΩ ±0·2%±2mΩ 20mV 1mA
199·99Ω 10mΩ ±0·2%±20mΩ 20mV 100μA
1999·9Ω 100mΩ ±0·2%±0·2Ω 200mV 100μA
Measurement modes Manual, Auto Continuous, High Power, Unidirectional
Test current accuracy ±10%
Output current stability >10ppm per sec @ 10mA; >100ppm per second @ higher currents
Voltmeter input impedance > 200kΩ
Hum rejection Less than 1% +20 digts additional error with 100mV rms 50/60Hz onpotential leads. If exceeded, a warning lamp will illuminate.
Battery capacity 7Ah NiMH rechargeable battery
Battery life Typically 1000 x 10A tests
Recharging External 115/230Hz charger or 12V car battery
Standard charging rate 4 hours
Quick charging rate 2.5 hours to 90% capacity @ 20°C
Operating temperature +5 → +45 °C full specification; -10 → +50 °C reduced accuracy
Error v. temperature <0·01% per°C over range 5 to 40°C
Standard charge 0 → +45 °C
Fast charge +10 → +45 °C
Safety EN61010-1 600V Category III, (with DH6 handspike set)
Size (HxWxD) & Weight 220 x 100 x 237mm, 2.6kg
Full scale Resolution Accuracy Volts (full scale) Test Current
1·9999mΩ 0·1μΩ ±0·2%±0·2μΩ 20mV 10A
19·999mΩ 1μΩ ±0·2%±2μΩ 20mV 1A
199·99mΩ 10μΩ ±0·2%±20μΩ 20mV 100mA
Supplied with: 4 earth test stakes, 4 connection leads, 8 x AA NiMH rechargeable batteries, hard carry
case, mains charger, quick start guides, user guide on CD
Supplied with: 4 earth test stakes, 4 connection leads, 8 x AA alkaline batteries, hard carry case, quick
start guides, user guide on CD
Stock no. Price per OM S$ S$ S$
410-0110S unit 1+ 8070·00
Resistance range 0.01 to 20kΩ Test frequency Hz 94.105.111 Accuracy 2% ± 3 digits Earth current range with ICLAMP 0.5mA to 19.9A Ingress protection IP54 Display LCD with back light Output ±25V or ±50V Operating temp. -15 → +55 °C
Resistance range: 0.01 to 20,000Ω Earth current range with ICLAMP 0.5mA to 19.9A Accuracy: 2% ± 3 digits Display: LCD with back light Ingress protection: IP54 Operating temp: -15 → +55 °C Output ±25V or ±50V at 128Hz
Support accessories:
Description Stock no. Price per OM S$ S$ S$
DET4 TCR2-RS 489-674S unit 1+ 2000·00
ICLAMP 514-4672 unit 1+ 460·00
DH5 straight duplex handspike set with 2.5m long leads. See stock no. 666-7371
Description Stock no. Price per OM S$ S$ S$
DET4 TC-RS 489-664S unit 1+ 1480·00
VCLAMP 104-767 unit 1+ 415·00
ICLAMP 514-4672 unit 1+ 460·00
Supplied with: DH4 duplex handspikes with 1.2m lead length, test lead pouch (lid mounted) user
guide on CD ,6V 7Ah sealed lead acid battery (fitted)
Test Current Resistance Range Resolution Accuracy * Full scale voltage Max. power output
10 A 0 → 2500.0 μΩ 0.1 μΩ ±0.2% ±0.2 μΩ 25 mV 0.25 W
1 A 0 → 2500.0 mΩ 100 μΩ ±0.2% ±200 μΩ 2.5 V 2.5 W
10 A 0 → 250.00 mΩ 10 μΩ ±0.2% ±20 μΩ 2.5 V 25 W
* The accuracy stated assumes forward and reverse measurements.Inductive mode or unidirectional mode will introduce an undefined error if an external EMF is present
Noise rejection: <1% ±20 digits additional error with 100 mV peak 50/60 Hz. on the potential leads.Warning will show if hum or noiseexceeds this level.
Battery capacity 6V 7AH sealed lead acid
Battery Life 1000 Auto (3 sec) tests
Charging time 8 hours
OperatingTemperature
+5 °C → +45 °C full specification, -10 °C → +50 °C reduced accuracy
Portable 10A Micro-ohmeter for testing the quality of
mechanically bonded metalwork, contacts and switches,
Dust and Drip Proof
Allows quick checking of earth loops without
disconnecting the earth cable under test
Push button controls for single handed operation
Ground resistance range : 0.050 Ω to 1500 Ω
True RMS Ground leakage current range : 0.2 mA to 35 A
Auto ranging & HOLD function
4 digit plus 6 digit backlit LCD display
High and low resistance alarms
256 test results storage & recall
Real time date & time stamping of results
Oval clamp for easy access to earth cables & earth straps
37mm dia conductor & 50mm earth strap capacity
Low maintenance flat jaw interface
EN61010 Safety rating CATIV 600V
Extended battery life
Dust and drip proof (desgined to IEC60529 IP54)
An earth ground clamp meter to simplify ground loop testing also known as
’stakeless’ earth ground testing with no need for placing earth stakes and
disconnecting the earth system from the electrical installation.The Fluke 1630 is
ideally suited for the following applications:,Ground loop checks on any earthing
system;,Continuity tests on earth bonding circuits and connections;,Inspection of
lightning protection systems.
Precision measurement and test leads for simplified two wire
measuring system supplied as standard accessories
Automatic warning when resistance of auxillary earth spikes is in
excess of tolerance
Small, lightweight and shock resistant
A wide ground loop resistance range, from 0.025Ω to 1500Ω, to satisfy all
requirements
33mm jaw size for tests on ground conductors and/or equipotential bus bars
Measurement of ground leakage current, from 0.2mA to 1000mA, without needing
to disconnect - ideal for system troubleshooting
Wide true RMS ac current measurement range from 0.2A to 30A allows one
instrument for multiple applications
User-defined HI/LO alarm limits, for rapid measurement evaluation
Display-HOLD function to freeze measurements
resistance of cables and heating of motors and transformers.
DET24C Additional Features
0 to 1200Ω measuring range
Measurement of leakage current from 1 to 30mA
Earth “Noise” indicator to maintain highest accuracy
Large 32mm clamp diameter
Sealed flat face jaws for ease of cleaning and reliability
User suitable alarm thresholds
99 measurement capacity
Visual indicators for battery life, Jaws closed and Display
Hold
Precision measurement and two wire measuring system supplied as
accessories
Capable of measuring earth voltage
Recording function for automatic storage of measured values, which can be recalled later on the
LCD display
Automatic self calibration ensures correct measurement every time
Complies with EN61010-1 CAT III 300V
Overload protection: 200 A
Standards: IEC 61010-1, CAT III 300V Pollution Degree 2, IEC61557
Supplied with: Alkaline battery and carrying case.
Large backlit LCD display
Broad measurement range 1μΩ to 2,500Ω
Temperature compensation of readings to allow for temperature
variations
4 wire measurement with automatic compensation for spurious
voltages
Automatic detection of the presence of external AC or DC voltages
on the terminals to disable measurements where accuracy cannot be
guaranteed
3 measurement modes:
Inductive mode for measurements on inductive components
(transformers, motors, etc.)
Non-inductive mode for measurements on resistances, with a time
≥ 8 hours battery life (continuous operation)
IrDA to USB interface for download
Standards: IEC 61010-1, CAT III 300V Pollution Degree 2, IEC61557
Resistance 0.1Ω to 1.2kΩ in 7 ranges Alarm Adjustable thresholds from 1 to 199ΩResolution (Ω) 0.01 at 0.1 to1Ω Safety Complies with EN61010-2-032 1500V,
cat III, pollution level 2 Frequency of use(Hz)
2400 Power supply 1 x 9V alkaline or NiCD battery
Current 1 to 300mA; 0.3 to 3.00A; 3 to 30A Size (HxWxD) &Weight
55 x 100 x 235mm, 1kg
Resolution (mA) 1mA @ 3.0mA; 10mA @ 3 to 30A
2000 test results storage
PowerDB LiteTM software
constant of a few ms (contacts, metallization, etc.)
Non-inductive mode with automatic triggering for measurements on resistances with no time
DC Voltage Accuracy ± (1.0% rdg + 2d) AC Voltage Lowest Range Resolution 0.1V DC Voltage Lowest Range 200V Resistance Accuracy ± (1.0 % rdg + 2d) DC Voltage Highest Range 600V Resistance Lowest Range 200ΩDC Voltage Lowest Range Resolution 0.1V Resistance Highest Range 20MΩ
AC Voltage Accuracy (45 to 60 Hz) ± (1.5% rdg + 3d) Resistance Lowest Range Resolution 0.1ΩAC Voltage Lowest Range 200V Dimensions & weight 185mm x 50mm x
35mm; 170g AC Voltage Highest Range 750V
Note: Please contact RS for calibration requirements
Current range 0.1 to 300A Accuracy ±(1.7%+5d) at 40 to 500Hz Accuracy ± (1.9%+0.5A) at 50 to 60Hz Resistance ranges 300Ω to 30.0MΩ
Max. cable size 29mm diameter Accuracy from ±(1%+2d) to ±(3%+5d) d.c. voltage range 300mV to 600V Safety
specification Designed to meet IEC 61010-1,Installation Category III 300V
Accuracy ±(0.7%+2d) Size (HxWxD) &Weight
102 x 72 x 36mm, 150g
a.c. voltageranges
300mV to 600V
AC Voltage 600V AC Accuracy ± (3% + 3 digits) AC Accuracy ± (1.5% + 3 digits) Ohms 2000ΩDC Voltage 600V Ohms Accuracy ± (1% + 2 digits) DC Accuracy ± (1% + 2 digits) Continuity Beeper 25 Ω beep on/ >300 Ω beep off AC Current 200A Size (HxWxD) & Weight 84 x 175 x 31mm, 280g
Note: T5 accessory kit available containing TP220 test probes, AC285 alligator clips, C33 soft zippered
case
Stock no. Price per OM S$ S$ S$
697-3989 unit 1+ 145·50
Measurement Range Resolution Accuracy
AC & DC Current 200 A 0.1 A ± (2% + 5d )
AC & DC Voltage 600 V 0.1 V ± (2% + 5d )
Resistance 6000 Ω 0.1 Ω ± (1% + 5d )
Jaw capacity 17mm ∅
Stock no. Price per OM S$ S$ S$
697-4064S unit 1+ 158·00
Stock no. Price per OM S$ S$ S$
697-3991 unit 1+ 139·50
Supplied with: Hard carry case & batteries
T5-600 T5-1000
AC voltage 600V rms 1000V rms
AC voltage accuracy ± (1.5% +2 digits) ± (1.5% +2 digits)
DC voltage 600V 1000V
DC voltage accuracy ± (1% + 1 digit) ± (1% + 1 digit)
AC current 100A 100A
AC current accuracy ± (3% + 3 digits) ± (3% + 3 digits)
Ohms 1000 ohms 1000 ohms
Ohms accuracy ± (1% + 2 digits) ± (1% + 2 digits)
Input impedance V ac/dc 1Mohm >100pf 1Mohm >100pf
Ohms <2.6kOhm <2.6kOhm
Safety IEC1010 CAT III 600V IEC1010 CAT III 1000V
Battery life 400 hrs typical 400 hrs typical
Size (HxWxD) & Weight 31 x 51 x 203mm, 300g 31 x 51 x 203mm, 300g
Description Stock no. Price per OM S$ S$ S$
T5-600 291-9372S unit 1+ 173·00
T5-1000 292-1230S unit 1+ 234·00
AC Current 100mA - 30A Earth Resistance (Autorange)
200 - 1200Ω
Operating System Earth resistance function : Constant voltage injection, Current detection, (Frequency : Approx.2400Hz) Dual Integration AC current function : Successive Approximation
Response Time Approx.7 seconds (Earth resistance), Approx.2 seconds (AC current) Sample Rate Approx. 1 times per second Current Consumption Approx. 50mA (max. 100mA) Withstand Voltage AC5320Vrms / 5 seconds, Between the Transformer jaws fitted parts and Case enclosure
AC current clamp designed for safe, non-intrusive AC current
Replacement test leads to suit ISO–TECH and most other
digital multimeters. Fitted with right-angled 4mm shrouded
plugs and supplied with probe tip insulators to prevent
accidental short circuits and a pair of crocodile clips.,Probes
designed to meet BS EN 61010-1 (safety standard) 1000V Cat
III.,Current rating 10A.
Two clamp multimeters able to measure ac current up to 600A, ICM33R II has true rms
reading in AC current and AC voltage measurement.
Fully automatic intelligent tester that selects the measuring function dependant on
input terminal and current clamp conditions. No range of function selection is
necessary by the user. The priority is AC voltage, DC voltage, resistance then AC
current.
Three clamp meters designed to measure AC current, AC/DC voltage and
resistance.
A clamp multimeter designed to measure AC currents up to
Featuring current clamp, multimeter and thermometer functions the ICM134 is ideally
suited to HVAC and electrical maintenance applications up to 600A ac.
3 1/2 2000 count LCD
600V ac voltage measurement
2000Ω resistance range
Continuity beeper for <50Ω
Display hold
600V circuit protection
34 mm conductor jaw capacity
Powered by 1x alkaline PP3 battery (supplied)
Safety to EN 61010-1 CAT III 600V
Rugged construction with fire retardant, high-impact plastic case
4000 count large backlit LCD display
750V ac / 1000dc voltage measurement
600A ac current measurement
4000μA dc current measurement ideal for flame sensor testing
40MΩ resistance measurement.
4mF capacitance measurement
-40 °C to 400 °C type K thermocouple temperature measurement input & sensor
Continuity & diode test
Display hold function
32mm conductor jaw size
Complies with IEC 61010-1 CAT III 600V, CAT II 1000V
400A, including ac/dc voltage and resistance measurement.
600V a.c./d.c. voltage measurement
Continuity beeper below 30Ω
Auto shut-off to maximise battery life
Display hold keeps measurements on the display
Ergonomic control layout
30mm jaws
Lightweight design
Safety rating IEC 1010-2-032 (safety standard) Cat III 600V
Type Test Lead Connection Type Shrouded Right Angle Plug
measurement upto 400 Amps
10000 counts LCD display with annunciators
Auto sensing on ACV, DCV, Ω, ACA
600A ac measurement capability
750V ac/ 1000Vdc measurement range
2kΩ resistance range
Continuity and Diode Test
32mm conductor jaw capacity
Display hold
Auto–power off
Conforms to EN61010-1 (safety rating) CAT IV 600V, CAT III 1000V
3 3⁄4 digit LCD, 4000 count display
Auto-ranging
Convenient pocket size
40, 400Aac current measuring ranges
2% basic AC current accuracy
600Vac/dc voltage measurement
400Ω resistance range with continuity beeper below 40Ω
Data hold function
27mm conductor jaw capacity
Auto power-off
Powered by 2x AAA alkaline cells (supplied)
Safety to EN61010 - 1 CATIII 300V, CATII 600V
Description Stock no. Price per OM S$ S$ S$
Test leads 243-2998 unit 1+ 27·90
334 Additional Features:
Supplied with: 9V battery, carry case, test leads, type K thermocouple adaptor and
2000 count Large-scale LCD display
AC current measuring up to 400 Amps
Data Hold
Max Hold
Easy battery replacement
27mm dia. conductor size
1.2m Drop Proof
Auto power off to maximise battery life
Safety to EN61010-1 CAT. III 600V
Supplied with: Carrying case, test leads, 9V PP3 battery.
Supplied with: carry case, 2 x AA batteries, users instructions & test leads.
Back-lit display
In-rush current measurement
DC Voltage Accuracy ± (1.0% rdg + 2d) AC Voltage Range Resolution 0.1V DC Voltage Range 1.5V to 999V Resistance Accuracy ± (1.0 % rdg + 2d) DC Voltage Lowest Range Resolution 0.1V Resistance Range 2000Ω
AC Voltage Accuracy (50 to 500 Hz) ±(1.5% rdg + 3d) Resistance Range Resolution 0.1ΩAC Voltage Range 1.0V to 750V Dimensions & weight 200mm x 83mm x 40mm; 395g
Range/Resolution Accuracy
AC current 200A / 0.1A600A/1A
± 1.9% +5d, 50 to 60Hz±1.5% +5d (0 to 400A) 50-60Hz±2.5% +5d (400 to 600A) 50-60Hz
AC voltage 600V / 1V ±1.2% +3d 40Hz to 500Hz
Resistance 200Ω / 1Ω ±1.5% rdg +2dgt
Size (HxWxD) & Weight 200 x 76 x 41mm, 360g
type K bead sensor, users manual, vinyl belt pouch.
Supplied with: PP3 battery (installed), Manual, and Carrying case
Supplied with: Test leads, carry case, batteries.
Description Stock no. Price per OM S$ S$ S$
ICM A6 697-3998 unit 1+ 175·00
335 Additional Features:AC Current Range (50 - 60Hz) 20.0A 200.0A 400A Basic Accuracy (50 - 60Hz) ±(3.0%+0.05A) ±(2.0%+0.5A) ±(2.0%+5A) Conversion Type Average sensing Maximum Conductor Size 27mm dia Battery Life 200 hours typical Size (HxWxD) & Weight 56 x 180 x 32mm (WxLxH), 250g
Range Resolution Accuracy Frequency
Range
AC Current 40A 0.01A ± (2% reading + 10 digits) 50/60Hz
400A 0.1A ± (2% reading + 10 digits) 50/60Hz
DC Voltage 400V 0.1V ± (1% reading + 5 digits) –
600V 1V ± (1% reading + 5 digits) –
AC Voltage 400V 0.1V ± (1.5% reading + 10 digits) 40 - 600Hz
600V 1V ± (1.5% reading + 10 digits) 40 - 600Hz
Resistance 400Ω 0.1Ω ± (1% reading + 5 digits) –
Size (HxWxD) & Weight 192 x 64 x 31mm, 250g
Range Accuracy Resolution
Volts DC 4 to 1000V ±(0.9% + 2d) 1mV
Volts AC 4 to 750V ±(1.5% + 5d) 1mV
Current AC 0 to 600A ±(1.9% + 1A) 0.1A
Current DC 0 to 4000μA ±(1% + 2d) 0.1μA
Resistance 0 to 40MΩ ±(0.7% + 2d) 0.1Ω
Temperature -10 to 400 °C ±(1% + 4 °C) 0.1 °C
Capacitance 4nF to 4000μF ±(2.0% + 8d) 1pF
Continuity <=30Ω
Maximum jaw capacity 32mm
Dimensions & weight 212 x 84 x 40 mm, 390g
Description Stock no. Price per OM S$ S$ S$
ICM33 II 697-3976 unit 1+ 186·00
ICM33R II 697-3979 unit 1+ 205·00
Stock no. Price per OM S$ S$ S$
697-3960 unit 1+ 105·50
Stock no. Price per OM S$ S$ S$
697-3954 unit 1+ 235·00
True rms current measurement
Back-lit display
In-rush current measurement
Stock no. Price per OM S$ S$ S$
697-3709 unit 1+ 149·50
Supplied with: TL 75 test leads, soft carry case, 2 x AA batteries.
Terminal cover to avoid the use of incorrect terminals
Peak function to measure current peaks
Supplied with: Soft carry case, 2 x AA alkaline batteries and instructions
complex loads. Because of its unique set of functions the F3N
can be used for a wide range of power electronic applications:
measurement of peak motor start currents to determine the crest
factor, estimation of the harmonic content of a signal, recording
average consumption over a 24 hour (or other) period or check
for imbalances in motors, checking variable speed drives and
generator sets, etc.
Tear drop shaped jaws for ease of use in crowded
cable areas
Supplied with: Test leads, carry case, instruction leaflet and 9V PP3 alkaline battery.
Note: Colour may differ from that shown.
AC Current 400/600A±1.5% rdg ±4 dgt (50/60Hz)±2% rdg ±5 dgt (40∼400Hz)
AC Voltage 400/750V±1.2% rdg ±3dgt [50/60Hz]±1.5% rdg ±4dgt [40∼400Hz]
Resistance 400/4000Ω ±1.5% rdg ±2dgt Frequency Response 40Hz-400Hz Continuity Check buzzer sounds below 50Ω±35ΩConductor Size ∅33mm max. Withstand Voltage 3700V AC for 1 minute Dimensions 195(L) × 78(W) × 36(D)mm Weight 260g
Three functions of AC current, AC voltage & resistance
4-digit 10,000 count display with bar graph
True rms reading with crest factor capability of 5
Frequency measurement from 0.5Hz to 10kHz
Peak (2ms) mode enables measurement of half cycle peak
current values
Smooth mode averages last 3 readings to reduce display
Supplied with: Test leads, carry case, instruction leaflet and 9V PP3 alkaline battery.
ac voltage Basic Accuracy ±(1.9% rdg + 5d) 50-60Hz Ranges 400V & 750V Resistance
Resolution 0.1V & 1V Range 400ΩBasic Accuracy ±(1.0% rdg+ 5d)
50 to 500Hz Resolution 0.1Ω
dc voltage Basic Accuracy ±(1.0% rdg+ 3d) Ranges 400V & 1000V Frequency counter
Resolution 0.1V & 1V Ranges 4kHz & 10kHz Basic Accuracy ±(0.7% rdg+ 2d) Resolution 1Hz & 10Hz ac current Basic Accuracy ±(0.1% + 2d) @5V rms max Ranges 400A & 1000A Size (WxHxD) and Weight 90 x 275 x 51mm, 420g Resolution 0.1A & 1A
Standards: IEC 61010-1 CAT III 600V, IEC 61010-1 CAT II 1000V, IEC61010-2-031, IEC 61010-2-032
Note: Please contact RS for calibration requirements
AC A 400/2000A Conductor Size ∅55mm max. AC V 40/400/750V Power Source R6P(AA) (1.5V) x 2 approx. DC V 40/400/1000V 150 hours continuous use
400Ω/4k/40k/400k Ω Dimensions (mm) 247 (L) 105 (W) 49 (D) Continuity 400Ω Weight 470g approx. Output Voltage 400/2000A DC 400mV/200mV
Measurement Range Resolution Accuracy
AC Current 600 A 0.1 A 2% ± 5 digits
AC Voltage 600 V 0.1 V 1.5% ± 5 digits
DC Voltage 600 V 0.1 V 1% ± 5 digits
Resistance 6000 Ω 0.1 Ω 1% ± 5 digits
Capacitance 1000 μF 1 μF 1.9% ± 2 digits
Fixed jaw capacity 32mm diameter (750 MCM)
Stock no. Price per OM S$ S$ S$
255-027 unit 1+ 91·50
flicker on both current and frequency
Record mode allows the max., min. and average current or frequency to be displayed
Live bar graph displays the current whatever the operating mode
Designed to meet IEC 1010 600V CAT III safety standards
Stock no. Price per OM S$ S$ S$
697-3945 unit 1+ 265·00
ac voltage Basic Accuracy ±(1.9% rdg + 5d) 50-60Hz Ranges 400V & 600V Resistance
Resolution 0.1V & 1V Range 400ΩBasic Accuracy ±(1.0% rdg+ 5d)
50 to 500Hz Resolution 0.1Ω
dc voltage Basic Accuracy ±(1.0% rdg+ 3d) Ranges 400V & 600V Frequency counter
Resolution 0.1V & 1V Ranges 4kHz & 10kHz Basic Accuracy ±(0.7% rdg+ 2d) Resolution 1Hz & 10Hz ac current Basic Accuracy ±(0.1% + 2d) @5V rms max Ranges 400A & 600A Size (WxHxD) and Weight 76 x 220 x 50mm, 360g Resolution 0.1A & 1A AC A 200/600A
AC V 200/600V
Ω 200Ω buzzer sounds below 30 ±20Ω
Conductor size ∅33mm max.
Frequency Response 45Hz to 1kHz
Power Source 6F22 (9V) x 1
Dimensions (mm) 208 (L) 91 (W) 40 (D)
Weight 400g approx.
Stock no. Price per OM S$ S$ S$
420-0737 unit 1+ 270·00
Description Stock no. Price per OM S$ S$ S$
Fluke 373 705-1948S unit 1+ 328·00
Supplied with: Alkaline 9V PP3 battery (fitted), instruction manual, carrying holster with belt clip.
Stock no. Price per OM S$ S$ S$
697-3957 unit 1+ 215·00
Manu. Part
No.
Stock no. Price
per
OM S$ S$ S$
2017 420-1061 unit 1+ 117·00
Measuring range 0.3A to 400A trms (700A for sine) Accuracy 400A range ±5% of reading (400 - 700A) Range overload limits 700A rms or 1000A crest Frequency Current measurement 10Hz to 1kHz
Frequency measurement 0.5Hz to10kHz
Accuracy 40A range ±(2% rdg +20 digits) Crest factor 2.5 max. at 400A at 45 to 65Hz 5 max. at 40A at 45 to 65Hz
Accuracy 400A range ±2% of reading (<400A) Size (WxHxD) andweight
AC A 20/200A Power Source 1.5V button cell x2 type LR-44 Conductor Size ∅24mm max. Dimensions (mm) 147 (L) 58.5 (W) 26 (D) Frequency response 50Hz to 1kHz Weight 100g approx. Withstand Voltage 3700V AC for 1 minute
Function Range Ohms 0.1 to 200Ω
ac Voltage (Autorange) 0.1 to 200V and 1 to 600V Continuity Approx. 100Ω
ac Current (Autorange) 0.1 to 200A and 1 to 600A
Supplied with: Carry case, battery and instruction manual
Conductor Size Ø 24mm max. Measurement method Average value Frequency Response 40 - 400Hz Effect of external stray magnetic field Ø15mm @ 100A 10mA AC max. Withstand Voltage 3700V AC for 1 minute Power Source 2 × LR44 (1.5V button cell) Size (LxWxD) and Weight 149 × 60 × 26mm, approx. 120 g
Supplied with: Test leads, battery, carry case and instructions
Note: Please contact RS for calibration requirements
Dual Hall sensor nickel-steel alloy jaw mechanism
1.0% basic dc/ac current accuracy
22mm diameter conductor jaw capacity
Safety to EN 61010-1 CAT III 300V, CAT II 600V
Maximum a.c. Current (A) 600 Resolution d.c. Current (mA) 100 Resolution a.c. Current (A) 0.1 Basic Accuracy d.c. Current ± 1.9% Rdg +2 digits Basic Accuracy a.c. Current ±1.5% rdg +5 digits Size (HxWxD) and Weight 203 x 81 x 39mm,
310g Maximum d.c. Current (A) 600
Supplied with: Manual, LR6 alkaline battery, software, USB cable & portable case
Stock no. Price per OM S$ S$ S$
697-3982 unit 1+ 240·00
Range Resolution Accuracy
AC Current 400A 0.1A ±(1.9% rdg + 5d) 50-60Hz 600A 1A ±(1.9% rdg + 5d) 50-60Hz
AC Voltage 400V 0.1V ±(1% rdg + 5d) 50-500Hz 600V 1V ±(1% rdg + 5d) 50-500Hz
DC Current 400A 0.1A ±(1.5% rdg + 5d) 600A 1A ±(1.5% rdg + 5d)
DC Voltage 400V 0.1V ±(0.7% rdg + 2d) 600V 1V ±(0.7% rdg + 2d)
Resistance 400Ω 0.1Ω ±(1% rdg + 3d) Frequency 4kHz 1Hz ±(0.1% rdg + 2d) Size (HxWxD) and Weight 235 x 88 x 52mm, 280g
Size and Weight Model 5000: 111 x 60 x 36 mm, 255 g
Model 5001: 111 x 60 x 42 mm, 315 g
Power Model 5000: Alkaline battery LR6 x 4
Model 5001: Alkaline battery LR6 x 6
Maximum a.c. Current (A) 300 Maximum d.c. Voltage (V) 600 Resolution a.c. Current (mA) 10 Resolution d.c. Voltage (mV) 0.1 Basic Accuracy a.c. Current (%,mA) ±(3% rdg +3 digits)
(50 to 60 Hz) Basic Accuracy d.c. Voltage (V, mV) ± (0.5% rdg + 2
digits) Maximum d.c. Current (A) 300 A Resistance Range 400Ω to 40MΩ
Resolution d.c. Current (A, mA) 10 mA Resistance Resolution (Ohms) 10KΩ (40 MΩ
range) Basic Accuracy d.c. current (A, mA) ±(2% rdg +2 digits) Resistance Accuracy (%, Ohms) ±(2.5% rdg +5 digits)Maximum a.c. Voltage (V) 600 Maximum Jaw Capacity (mm) 22 Resolution a.c. Voltage (V) 1 Size (HxWxD) and Weight 192 x 66 x 27mm,
205g Basic Accuracy a.c. Voltage (%, Mv, V) ± (1.5% rdg +5
Frequency counter 20 to 400Hz/1Hz ±(0.1% + 2d) @ 5V rms max
Size (HxWxD) and Weight 275 x 90 x 51mm, 420g
Additional error due to remanence: 1% of current peak max.
AC A 400/2000A Output Voltage 400/2000A, DC 400mV/200mV AC V 400/750V Conductor Size ∅55mm max. DC A 400/2000A Power Source R6P(AA) (1.5V) x 2 DC V 400/1000V Approx. 100hours in continuous use Ω 400/4000Ω Dimensions (mm) 250 (L) 105 (W) 49 (D) Continuity 400Ω Weight 530g approx.
Supplied with: C43 soft case, 6 AA alkaline batteries, TL224 1.5m silicone test leads,
Supplied with: C43 soft case, 6 AA batteries and users manual
4000 count LCD display
DC current measurements to 2500A
AC current, true rms and Crest Factor to 2000A
AC/DC voltage to 600V
Max./min. hold
Resistance and continuity measurement
Diode Test
Frequency measurement
Low battery indication
Digital and bar graph display
AC A 40/300A (Autoranging) Power Source 1.5V button cell x 2 type LR-44 or SR-44 DC A 40/300A (Autoranging) Dimensions (mm) 147 (L) 59 (W) 25 (D) Conductor Size ∅24mm max. Weight 100g approx.
AC A 400/2000A Output Voltage 400/2000A, DC 400mV/200mV AC V 40/400/750V Conductor Size ∅55mm max. DC A 400/2000A Power Source 6F22(9V) x 1 approx. DC V 40/400/1000V 15 hours in continuous use Ω 400/4000Ω Dimensions (mm) 250 (L) 105 (W) 49 (D) Continuity 400Ω Weight 540g approx. Frequency 10 to 4000Hz
Stock no. Price per OM S$ S$ S$
420-0765 unit 1+ 270·00
Stock no. Price per OM S$ S$ S$
420-0743 unit 1+ 500·00
Stock no. Price per OM S$ S$ S$
697-3951 unit 1+ 405·00
Contact RS for calibration requirements
Contact RS for calibration requirements
Note: Colour may differ from that shown.
Stock no. Price per OM S$ S$ S$
420-0759 unit 1+ 570·00
Voltage Range AC/DC 0-4.000 V, 0-40.00 V, 0-400.0 V, 0-600 V ACrms, 0-1000 V DC
Basic Accuracy 1% ± 5 counts
Current Range AC/DC 0-40.00 A, 0-400.0 A, 0-2000 A; 1400 AC rms
Basic Accuracy 1.5% ± 5 counts
Resistance range 0-400.0 Ω, 0-4.000 kΩ, 0-40.00 kΩ, 0-400.0 kΩ
1.5% ± 5 counts
Frequency Measurement Range 5.0Hz to 100Hz 101Hz to 1kHz
Basic Accuracy 0.2% ± 2 counts 0.5% ± 5 counts
Size (H x W x D) and weight 300 x 98 x 52mm: 814g
Current Range AC/DC 0-40.00 A, 0-400.0 A, 0-2000 A, 1400 AC rms
Basic Accuracy 1.5% ± 5 counts 1.5% ± 5 counts
Frequency Measurement Range 5.0Hz to 100Hz 101Hz to 1kHz
Basic Accuracy 0.2% ± 2 counts 0.5% ± 5 counts
Size (H x W x D) and weight 300 x 98 x 52mm: 814g
Maximum a.c. current 2100A Maximum d.c. voltage (V) 0.4; 4 ; 40; 400; 600 Resolution a.c. current (A) 0.1 (400 A); 1 (1000 A); 1 (2100
A) Resolution d.c. voltage 0.1 mV (400 mV); 0.001 V (4 V);
0.01 V (40 V); 0.1 V (400 V); 1 V (600 V)
Basic accuracy a.c. current ± 3% ± 5 digits (40 to 1 kHz) Basic accuracy d.c. voltage ± 1.5% Rdg ± 3 digits Maximum d.c. current (A) 400; 2000; 2500 Resistance range (Ω) 400; 4 kΩ; 40 kΩ;
Measurement Ranges AC Current equals +/- 2% rdg +/- 5 digits(50 - 60 Hz)
DC Current 0 to +/- 100 A Power Source R03 (AAA) x 2 AC Current 0 to 100A Dimensions (mm) 161.3 (L) 40.2 (W) 30.3 (D) Accuracy Weight 110g (with batteries) DC Current equals +/- 2% rdg +/-5 digits
Supplied with: 2 AA alkaline batteries, 1 pair TL75 test leads, 80BK integrated DMM
Temperature probe, users manual, soft carrying case.
Contact RS for calibration requirements
Stock no. Price per OM S$ S$ S$
255-023 unit 1+ 425·00
Stock no. Price per OM S$ S$ S$
466-6042 unit 1+ 205·00
Function Measurement ranges Accuracy
DC Voltage 40V, 400V, 600V ± (1% reading + 5 digits)
AC Voltage 40V, 400V, 600V ± (1.5% reading + 5 digits) 50-60Hz, CF<3
± (3.5% reading + 5 digits) 40Hz-1kHz
DC Current 400A, 1000A ± (1% reading + 5 digits)
AC Current 400A, 1000A ± (1.5% reading + 5 digits) 50-60Hz, CF<3
± (3.5% reading + 5 digits) 40Hz-1kHz
Frequency 3000 Hz ± (1.5% reading + 5 digits)
Resistance 400Ω, 4000Ω ± (1% reading + 5 digits)
Continuity buzzer Sounds at <20Ω on 400Ω range
Conductor size, AC/DC current Maximum 33mm Ø
Withstand voltage 5550Vac for 1 minute
Power Source 6F22 or equivalent (PP3 9V) battery
Size (LxWxD) and Weight 208 x 91 x 40 mm, approx. 450 g
Contact RS for calibration requirements
Stock no. Price per OM S$ S$ S$
543-289 unit 1+ 475·00
Range Accuracy Resolution
Volts DC 0 to 600V ±(1% + 5d) 0.1V
Volts AC 0 to 600V ±(1% + 5d) 0.1V
Current AC 0 to 600A ±(2% + 5d) 0.1A
Current DC 0 to 200μA ±(1% + 5d) 0.1μA
Resistance 0 to 9999Ω ±(1.5% + 5d) 0.1Ω
Temperature -10 → +400 °C ±(1% + 0.8°C) 0.1°C
Capacitance 1μF to 1000μF ±(1.9% + 2d) 0.1μF
Continuity ≤30 Ω
Maximum jaw capacity 30mm
Dimensions & weight 280 x 80 x 40 mm, 310g
Note: Image shows DCM400AD only, DCM400 is similar
1000Aac current range to check motor & compressor current consumption
40mm clamp diameter
Min/Max with elapsed time to capture motor inrush current readings
Data hold facility
1nF to 3500μF capacitance range suits run/start capacitor checks
1kHz frequency measurement range
Diode and continuity test
μA range to measure flame sensor current
6000 count large backlit LCD display
True RMS current & voltage measurement AC + DC coupled
1000V ac/dc voltage measurement
600A ac/dc current measurement
600kW active power measurement and PF display
Total Harmonic Distortion measurement
AC current inrush measurement ideal for motor & compressor checks
MIN/MAX, Display and PEAK hold
20kΩ resistance measurement.
-50 °C to 1000 °C type K thermocouple temperature measurement input & sensor
4kHz frequency counter
Continuity & diode testAC/DC power factor measurement
AC/DC voltage measurement
AC/DC current measurement
3 phase AC/DC balanced & unbalanced
Apparent power & reactive power
Phase angle
Frequency measurement
10,000 count 4-digit dual LCD display
Powered by 9V alkaline PP3 battery (supplied)
Dual 33⁄4 digit 4000 count displays
True RMS reading, Auto-ranging
Current and Voltage can be read simultaneously
AC and DC Voltage to 600V
AC Current to 400A
Resistance to 40MΩ with Continuity Buzzer
Micro-amp measurements for testing “Flame Sensors”
Temperature reading via Type-K thermocouple probe
Capacitance to 3000 μF
Frequency measurement
Diode test
Hold and Maximum reading functions
Auto power-off and low battery indication
Accommodates conductors up to 1.02" (26mm) in diameter
Rubber over-moulded case
100MΩ resistance range
Size (HxWxD) and weight: 228x76x39mm, 465g
Meets with EN61010-1 IEC1010-2-032 600V Cat III
900°C range Type K thermocouple input socket.
Analyse time-stamped temperature and power data
Supplied with: test leads, 9V PP3 battery
35mm conductor jaw size
Complies with IEC 61010-1 CAT III 600V, CAT II 1000V
Supplied with: case, battery & instructions
Supplied with: Test leads, 2 x croc clips, case, 9V PP3 battery,7 instructions
Supplied with: Test leads, carry case, type K thermocouple probe & battery
Safety EN 61010-1 Accuracy dc current ±(1.5% + 3 digits) Power measurements 40; 400; 1200 KW Maximum ac voltage (V) 600 Temperature measurement(°C)
-50 to 400; 400 to 1000 Resolution ac voltage (V) 0.001 (4 V); 0.01 (40 V); 0.1(400 V); 1 (600 V)
Maximum ac current (A) 2100 Accuracy ac voltage ±(1.5% + 3 digits) Resolution ac current (A) 0.1 (400 A); 1 (2100 A) Maximum dc voltage (V) 600 Accuracy ac current ±(2.5% + 5 digits) Accuracy dc voltage ±(1.5% + 3 digits) Maximum dc current (A) 2500 Maximum jaw capacity (mm) 55; 64 x 25 Resolution dc current (A) 0.1 (400 A); 1 (2500 A) Size (HxWxD) and Weight 271 x 112 x 26mm, 647g
Supplied with: PP3 9V battery, carry case, test leads, type K thermocouple adaptor and type K bead
sensor, users manual, vinyl belt pouch.
Measurement Range Accuracy
DC Voltage 1000V ±(0.7% +5d)
AC Voltage (45Hz ∼ 500Hz) 1000V ±(1.0% +5d)
DC Current 600A ±(1.5% +5d)
AC Current 600A ±(1.5% +5d) 45Hz ∼ 65Hz ±(2.5% +5d) 6Hz ∼ 500Hz
Power measurement (kW) 600kW Sum of voltage & current errors
Power Factor PF -1 to +1 ± 3°
THD measurement (Fundamental 45 – 65Hz)
0 ∼100% ±(3% +10d)
Inrush Current (Integration time ∼100ms)
10.0 ∼ 59.9Aac 60.0 ∼ 600A
±(2.5% +2A) ±(2.5% +5d)
Temperature measurement -50 to +1000°C ±(1% +3°C)
Dimensions & weight 235mm x 78mm x 41mm 400g
Safety BSEN 61010; BS 61010-2-032 Accuracy dc current (A,mA)
Frequency Measurement range: 46 Hz to 54 Hz and 56 Hz to 64 Hz
Harmonics and THD To 50th harmonic (< 50 % of nom)
Power measurementMeasuring range(P - Active, S - Apparent, Q- Reactive, D - Distorting)
see V-rms and A-rms measurement ranges
Energy Measurement (kWh,KVAh, kVARh)
1 W to 10 W resolution
PF (Power factor) 0.000 to 1.000
Events Detection of voltage dips, voltage swells and voltage interruptions with a 10msresolution and measuring error of the half period sine wave of rms
Memory 4 MB Flash memory, 3.5 MB for measuring data
Sample rate 10.24 kHz
Line frequency 50 Hz or 60 Hz, user-selectable, with automatic synchronization
Display VGA Graphic Color transmissive displays 320 x 240 pixels with additionalbackground lighting and adjustable contrast, text and graphics in color
Interface RS-232 SUB-D socket; 115.2 k Baud
Power supply NiMH battery-pack, with ac adapter (15V to 20V / 0.8A)
Operating temperature 0 °C → +40 °C
Size (HxWxD) 240 mm x 180 mm x 110 mm
Weight 1.7 kg, including battery
Current Clamp Options
Stock no. Price per OM S$ S$ S$
636-2809 unit 1+ 4934·00
i430Flex 3000A ac flexible current clamps (set of 4 supplied as standard with 435) range 30A to
3000A, maximum conductor diameter 160mm. Safety rating EN610101 CAT IV, 600V
i5sPQ3: 5Aac current clamps (3 in a set) range 10mA to 5A; maximum conductor diameter 15mm,
Safety rating EN610101 CAT III 600V
i1000s, ac current clamp (sold individually) range 0.1A to 1000 A rms, maximum conductor
diameter 54mm. Safety rating EN610101 CAT III 600V
Contact RS for calibration requirements
Note: 3 year warranty on Analyser units 434 & 435 only.
Supplied with: Hard carrying case (Fluke 434 with C434, Fluke 435 with C435 with handle and
wheels), 4 current probes, 5 test leads and crocodile clips, NiMH battery charger, BP190 NiMH
435 only), OC4USB optical USB cable, colour localisation set, quick start printed manual, user manual
CD.
Range Accuracy
Voltage Vrms (AC+DC) 1 to 1000V ±0.1% of nominal (FL435) ±0.5% of nominal (FL434)
Current Arms (AC+DC) 0 to 20000A ±0.5% ± 5 counts Frequency 42.50 57.50 Hz ±0.01% Harmonics DC, 1 – 50 (Off, 1 – 49) Power Watt,VA,VAR 1.0 – 20MVA ±1.0% ± 10 counts Energy * kWh,kVAh,kVARh 0.00 – 200.0 GVAh ±1.5% ± 10 counts Power Factor 0 - 1 ±0.03 Flicker Pst(1min),Pst,Plt,PF5 0.00 – 20.00 ±5% Unbalance Volts 0.0 – 5.0% ±0.15% Unbalance Current 0.0 – 20% ±1% Transient capture ±6000V ±2.5% of Vrms Min transient capture time 5μs Inrush Arms (AC+DC) 0.00 – 20.00 kA ±1% of measurement ± 5 counts Memory - Capacity 8MByte (FL434)
16MByte (FL435) Shared memory divided between logging, screens and datasets
Memory - Screens/Data 50/10 Standards Measurement method: IEC61000-4-30 Class A;EN50160;IEC61000-4; IEC61000-4-7 Battery life 7hours; 4 hour typical charging time Size (HxWxD) and Weight 256 x 169 x 64mm, 2kg
Balanced 3 phase and single phase 3000A power quality tester with
flexible 3000A probe and data logging functions for the
measurement and diagnosis of power problems in electrical
installations and power circuits. An optically isolated USB lead and
analysis software enables readings to be displayed and/or
downloaded for analysis on a PC or Laptop.
The Fluke 345 measures a wide range of electrical parameters for troubleshooting
The CA8220 is optimised for maintenance and
troubleshooting of electrical equipment, electrical systems
and in single phase and balance three phase systems.,The
CA8220 includes measurements for testing and monitoring
rotating machines in operation. including temperature,
current , duration of in-rush current, resistance of windings
and rotation speed.
power disturbances in single- and three phase electrical loads. With a bright colour
display to see waveforms and trends, a low-pass filter to remove high frequency noise,
and a high EMC immunity design, the Fluke 345 is ideal for measurements on
switching loads such as variable speed drives, electronic lighting and UPS systems.
True RMS measurement of Vac and Iac
Active power measurement (W, kW, HP)
Reactive power measurement (VAR, kVAR)
Apparent power measurement (VA, kVA)
Power factor (PF) and phase angle (Ø) measurements
Energy calculation (WH and kWH)
Measures balanced 3Ø power and sequence
Clamp-on measurement of ac current up to 1400A rms and dc current up to 2000A
without breaking the circuit
Low pass filter ensures the clamp meter is accurate in noisy environments even with
distorted waveforms present on electronic loads
Identify intermittent faults by logging any power quality parameter for minutes, or
over a month, including harmonics
Direct measurement of dc ripple (%) for battery and dc systems
Analyse and log harmonics digitally or graphically
Inrush current measurement to capture and analyse nuisance tripping, from 3 to 300
seconds
Large backlit 173-segment LCD display.
Power measurement up to 250kW (dependant on clamp selection)
600V rms and up to 6,500A (with clamps)
Harmonics (IEC 1000-4-7) display up to 50th order
MIN, MAX, AVERAGE, PEAK and Crest Factor display
W, VA, VAR power, DF, THD, CosΦ
Inrush current measurements – Max instantaneous value; Max RMS half-
cycle current value and duration of motor start.
RPM rotation speed
Resistance measurement
Simultaneous recording of all parameters, alarms and motor start up
currents.
RS232 direct output to PC
2 wire PT100 temperature probe input
Select AC current probes separately :-
Ampflex A193: 10 to 6500Aac (10Hz to 20kHz) 450mm long flexible probe
(rs 236-565)
MN93A: 0.2 to 120Aac (40Hz to 10kHz): Jaw size 20mm dia. (rs 236-559)
IP54 Rated
Large backlit colour display of waveforms (scope function) and trends
Balanced 3-phase power measurement capability
Power Log software supplied to view graphs and generate reports on a PC
USB interface
Harmonic analysis: Analyse, display and log harmonics up to the 30th harmonic (40th harmonic for
15Hz to 22Hz)
Verify batteries: Direct measurement of dc ripple (%) for battery and dc systems
EN61010 safety rating: 600V CAT IV / 1000V CAT III rated for use at the service entrance
Supplied with: Supplied with 6 off AA alkaline batteries, test leads, 4mm test
Fluke 43B Basic Fluke 43B
Power - 5 W Safety EN/IEC 61010-2-032; ANSI/ISA S82; CSA-C22.2 No.1010.1-92; UL 1244 Power Measurements 250W to 1.56GW Memory (Test results) Yes Phase Measurement Yes Phase Angle Accuracy ±3° to ±15°Power Factor 0 to 1.0 Capacitance Measurement Yes Temperature Measurement -100 to +400 C Maximum ac Current 1250kA (rms, ac + dc) Accuracy ac Current ± (1% +10 Counts) (rms, ac + dc) Maximum dc Current 1250kA (rms, ac + dc) Accuracy dc Current ± (1% +10 Counts) (rms, ac + dc) Maximum ac Voltage 1250V (rms, ac + dc) Accuracy ac Voltage (V, mV) ± (1% +10 Counts) (rms, ac + dc) Maximum dc Voltage 1250V (rms, ac + dc) Accuracy dc Voltage (mV, V, Percent) ± (1% +10 Counts) (rms, ac + dc) Continuity Check Yes Diode Test Yes Size (HxWxD) and Weight 232 x 115 x 50mm, 1.1kg
probes, crocodile clips, RS232/USB optical cable and instructions
Features & facilities
Standard available in all models 43B Basic 43B
Fliuke 43B Power Quality Analyzer YES YES
BP120MH Ni-MH Battery pack (Installed) YES YES
PM 8907 Battery Charger/Line Voltage Adaptor YES YES
TL24 Test Leads YES YES
AC20 Industrial test Clips YES YES
TP4 Slim Reach Test Probes (4mm) YES YES
BB120 Banana-to-BNC Adaptor plug YES YES
Model Difference
i400s AC Current Clamp (400 A) YES YES
SW43W FlukeView Software for Windows + Power Quality Video YES
OCBUSB Interface/Adaptor Cable YES
C120Hard Case YES
TP1 Slim Reach Test Probe Set (flat blade) YES
AC85 Large Jaw Alligator Clips YES
Users Manual / Application Guide (CD-ROM) YES YES
Getting Started Booklet YES YES
VPS40 Voltage Probe YES
Fluke 61 IR Thermometer YES
Supplied with: Test Leads, Power Log software on CD-ROM, USB lead, batteries(fitted), mains
adaptor, carry case & instructions.
Voltage range 6 VRMS to 600 VRMS AC+DC ±(0.5%+2pts) AC current range 5mA to 6500 A ±(0.5%+1pts) DC current range 1 A to 1700 A ±(1%+1pts) Fundamental frequency 40 Hz to 70 Hz Harmonics (IEC 1000-4-7) Up to 50th order Engine rotation speed 6 RPM to 120 kRPM ±(0.5%) Temperature (Pt100) 200°C to 850°C ±(1%+10pts) Resistance (coiling) 0.0Ω to 2000 Ω ±(0.5%+1 Ω) Phase rotation Yes, with display of phase order in three-phase IEC 61010-1 600 V, Cat. III
Current
DC, DC rms, AC rms All measurements dc and 15Hz to 1kHz. Amps rms is a true rms measurement (ac + dc)
Maximum overload 10,000 A or RMS x frequency < 400,000 Harmonics All measurements up to 30th harmonic (40th harmonic for 15 Hz to 22 Hz); Frequency range
F0 : 15 Hz to 22 Hz and 45 Hz to 65 Hz; Iacrms > 10A Measuring range 0 – 2000 A dc or 1400 ac rms Accuracy DC, rms I > 10 A: ± 1.5 % rdg ± 5 digits
I < 10 A: ± 0.2 A Voltage measurement
DC, DC rms, AC rms All measurements dc and 15 Hz to 1 kHz. Volts rms is a true-rms measurement (AC + DC)
Maximum overload 1,000 V rms. Measuring range 0 – 825 V dc or ac rms Accuracy DC, rms V > 1 V: ± 1 % rdg ± 5 digits
V < 1 V: ± 0.02 V Harmonics All measurements up to 30th harmonic; Frequency range F0 : 15 Hz to 22 Hz and 45 Hz to 65
Hz; Vacrms > 1V Power (single and three phase)
Watts measurement 0 – 1650 kW dc or 1200 kW DC, DC rms, AC rms Accuracy 2.5 % rdg ± 5 digits
W1Ø < 2 kW ± 0.08 kWW3Ø < 4 kW ± 0.25 kW
VA measurement 0 -1650 kVA dc or 1200 kVA ac DC, DC rms, AC rms Accuracy VA > 2 kVA: 2.5 % rdg ± 5 digits
VA < 2 kVA: ± 0.08 kVA VAR measurement (0.3 < PF< 0.99)
0 – 1250 kVAR
Accuracy VAR > 4 kVAR: ± 2.5 % rdg ± 5 digitsVAR < 4 kVAR: ± 0.25 kVAR
Power factor &Displacement power factor
0.3 capacitive to 1.0 to 0.3 inductive (72.5° capacitive to 0° to 72.5° inductive)
Accuracy 15 to 22 Hz ± 0.5 % rdg40 Hz to 70 Hz ± 0.5 % rdg15 Hz to 1000 Hz ± 1% rdg
Scope function
Time base 2.5 ms, 5 ms, 10 ms, 25 ms, 50 ms/div Current measurement: Ranges 10A/ 20A/ 40A/ 100A/ 200A/ 400A/ 1000A/ 2000A Accuracy ± 3 % rdg ± 1 pixel Voltage measurement: Ranges 4V/ 10V/ 20V/ 40V/ 100V/ 200V/ 400V/ 1000V Accuracy ± 2 % rdg ± 1 pixel Inrush current function All measurements dc and 15 Hz to 1 kHz Ranges 40, 400 and 2000 A Memory Up to 50 screen shots and over 150,000 individual measurement values Safety IEC 61010-1 600 V CAT IV, 1000V CAT III Display Color transmissive LCD 320 x 240 pixels (70 mm diagonal) with 2 level backlight Jaw opening 60 mm, max conductor 58 mm diameter Battery type 6 off 1.5 V Alkaline AA MN 1500 or IEC LR6 Battery Eliminator BE345 Input 110/230 V 50/60 Hz
ISO-TECH IPM6300 3000A acGraphical Power QualityAnalyser
ISO-TECH IPM6200 1500A acPower Quality AnalyserA single phase and balanced 3 phase 1500A ac graphical power quality analyser
with data logging functions for analysis and diagnosis of power quality & power
disturbance problems in electrical installations and power circuits. Optically isolated
USB connection lead & analysis software is supplied enabling readings to be
displayed and recorded data to be downloaded controlled and analysed on a PC or
laptop computer.
Balanced 3 phase and single phase 3000A graphical power
quality analyser with data logging functions for the analysis
and diagnosis of power quality and disturbance problems in
electrical installations and power circuits. An optically
isolated USB lead and analysis software enables readings to
be displayed and/or downloaded for analysis on a PC or
Laptop.
OC4USB: Optical USB interface
cable
BC430: Battery charger/mains
Power quality analysis of single and balanced 3-phase
systems
Graphical display of voltage and current waveforms
Active power measurement (W, kW, HP)
Reactive power measurement (VAR, kVAR)
Apparent power measurement (VA, kVA)
Power factor (PF) and phase angle (Ø) measurements
Power quality analysis of single and balanced 3-phase systems
Graphical display of voltage and current waveforms
128x64 Dot matrix LCD with backlight
Active power measurement (W, kW, HP)
Reactive power measurement (VAR, kVAR)
Apparent power measurement (VA, kVA)
Power factor (PF) and phase angle (Ø) measurements
Energy calculation (WH and kWH)
adapter
Flexible AC current clamps: Set of 4x i2000flex
flexible AC current clamps (2000 A)
WC100 colour localisation set: 32 metal clips for
identifying cables (8 colours)
Non-interrupted harmonic analysis (V and A) to the 50th order in % and magnitude
Dual display with fast Peak Hold, Max and Min functions
Selectable CT ratios from 1 to 1000
Data logging to internal memory for up to 8000 readings with programmable logging interval
Selectable Auto power-off up to 30 minutes
Energy calculation (WH and kWH)
Transient detection of Swell, Dip and Outage
Graphical harmonic analysis (V and A) to the 50th order in % and magnitude
Analysis of % THD
Graphical phase diagram display, plus fast peak display
Maximum demand measurement over presettable time period
128x64 Dot matrix LCD with backlight
Real time clock
Programmable CT ratio from 1 to 3000 for very high power measurements
Data logging to internal memory for up to 50000 readings/32000 transient events with
programmable logging interval
Programming logging interval from 1 to 3000 seconds
Maximum demand measurement over presettable time period
Transient detection of Swell, Dip and Outage
Analysis of % THD
Graphical phase diagram display, plus fast peak display
Graphical harmonic analysis (V and A) to the 50th order in % and magnitude
Real time clock
Programmable CT ratio from 1 to 3000 for very high power measurements
Data logging to internal memory for up to 50000 readings/32000 transient events with
programmable logging interval
Programming logging interval from 1 to 3000 seconds
Type Stock no. Price per OM S$ S$ S$
OC4USB cable 493-5540a unit 1+ 307·00
Note: Colour may differ from that shown.
Note: Support Accessories: Portable thermal dot matrix printers for results printout, see stock no. 697-
3787
Note: Colour may differ from that shown.
Note: Support Accessories: Portable thermal dot matrix printers for results printout, see stock no. 697-
3787
Supplied with: Opto-isolated USB lead, PC software on CD, Test leads with crocodile clips, Software
and User manuals, 2 x AA alkaline batteries
Note: Support Accessories: Portable thermal dot matrix printers for results printout, see stock no. 697-
3787
ac Current Range 50-60Hz True RMS, Crest Factor 4 0-3000A Resolution ac current 0.1A (0-999.9A), 1A (1000-3000A) Accuracy ac current ±1% of range (typical) ac Voltage Range 50-60Hz True RMS, Crest Factor <4 4-600V Resolution ac voltage 0.1V Accuracy ac voltage ±0.5% reading ±5 digits Power measurement 10W - 9999kW/kVA/kVAR Resolution power 0.1 (10W - 1kW/VA/VAR)
Phase angle (Ø, V>20V, I >30A) -180° to +180°: ±2°0° to 360°: ±2°
THD-F (50/60Hz, >80V, >20A, 1st to 50th Harmonics) 0 to 20%: ±2%20 to 100% :±6% of reading ±1%
Peak value of Voltage (RMS value >10V) ± 5%, ±30 digitsPeak value of Current (RMS value > 20A) ± 5%, ±30 digitsBattery 2 off AA alkaline Maximum conductor size 170mm
Supplied with: Opto-isolated USB lead, PC software on CD, Test leads with crocodile clips, Software
and User manuals, 2 x AA alkaline batteries
Supplied with: Opto-isolated USB lead, PC software on CD, Test leads with crocodile clips, Software
and User manuals, 2 off AA alkaline batteries
Stock no. Price per OM S$ S$ S$
697-3768 unit 1+ 770·00
Peak value of Current (RMS value > 20A) ± 5%, ±30 digitsBattery 2 off AA alkaline Maximum conductor size 55mm dia, 64x24mm bus bar
ac Current Range 50-60Hz True RMS, Crest Factor <4 4-1500A Resolution ac current 0.01A Accuracy ac current ±1% ± 5 digits ac Voltage Range 50-60Hz True RMS, Crest Factor <4 4-600V Resolution ac voltage 0.1V Accuracy ac voltage ±0.5% reading ±5 digits Power measurement 10W - 9999kW/kVA/kVAR Resolution power 0.1 (10W - 1kW/VA/VAR)
Phase angle (Ø, V>20V, I >30A) -180° to +180°: ±2°0° to 360°: ±2°
THD-F (50/60Hz, >80V, >20A, 1st to 50th Harmonics) 0 to 20%: ±2%20 to 100% :±6% of reading ±1%
Peak value of Voltage (RMS value >10V) ± 5%, ±30 digits
ac Current Range 50-60Hz True RMS, Crest Factor <4 0-3000A Resolution ac current 0.1A (0-999.9A), 1A (1000-3000A) Accuracy ac current ±1% of range (typical) ac Voltage Range 50-60Hz True RMS, Crest Factor <4 4-600V Resolution ac voltage 0.1V Accuracy ac voltage ±0.5% reading ±5 digits Power measurement 10W - 9999kW/kVA/kVAR Resolution power 0.1 (10W - 1kW/VA/VAR)
Phase angle (Ø, V>20V, I >30A) -180° to +180°: ±2°0° to 360°: ±2°
THD-F (50/60Hz, >80V, >20A, 1st to 50th Harmonics) 0 to 20%: ±2%20 to 100% :±6% of reading ±1%
Peak value of Voltage (RMS value >10V) ± 5%, ±30 digitsPeak value of Current (RMS value > 20A) ± 5%, ±30 digitsBattery 2 off AA alkaline Maximum conductor size 55mm dia, 64x24mm bus bar
CF card Interface Compact flash card (Standard type 32/64/128MB)
Crest factor Voltage : up to 2.5 Current :up to 3.0(with 90% fs or less)
Safety standard IEC61010-1 CAT.III 600V
Frequency meter range 40-70Hz Power supply AC Line : 100-240V±10% (50/60Hz) DC Battery 9V : LR6×6(Battery life approx. 7h)
Frequency meter accuracy ±3dgt Power consumption 10VA (MAX) Active Power accuracy ±0.5 % rdg ±0.2 % fs +
Clamp sensor accuracy [at45-65 Hz]
Dimension 175(L)×120(W)×65(D) mm
Accuracy precondition PF=1, Sine wave, 23°C±5°C Weight Approx. 800g (includingbatteries)
Single or 3 phase power kW, kVA and current
Power factor and phase angle
Total kVAr regardless of phase angle
True rms current measurement (3-phase)
True rms voltage (single phase)
Contact RS for calibration requirements
Single phase frequency
Software supplied with the Hawk 5000 enables configuration, on line monitoring, data collection
and analysis with colour graphics.
Safe simple operation requires no connection to live terminals
Status indicators confirm correct operation and guide user for current transformer placement
Phasing wand can be used to ensure correct phase allocation for the CTs
Pulse measuring capability (2 channel) enables logging from remote meters, or fluid flow meters
System accuracy better than 2% ± 1% of range with supplied current transformers
High data capacity enables monitoring for periods between 7 weeks and 38 weeks (dependant
upon detail and logging parameters selected)
Hawk Reporter Pro tariff analysis software for analysis and presentation of survey results in
detailed format
Operating voltage 70 V to 300 V Flickermeasurement
EN 61000-4-15
Min/Max/Avg RMSvalue
Resolution 0.125 V Number ofrecording channels
1 Phase to Neutral2 Phase/Neutral to Ground
Number of events 175,000 Recording time 1 day to 339 days depending onaverage time from 1 second to 20minutes
Dips/Interruptions Yes Transients Yes (>100μs) Time resolution 5 ms Frequency range 50 Hz ± 1 Hz and 60 Hz ± 1 Hz Voltage resolution 0.125 V Power cord
adapterscompatibility
Australia, Central America, Europe,Ireland, Italy, Japan, Malaysia, NorthAfrica, Singapore, Switzerland, UK, US
Over-voltages Yes Safety categoryrating
CAT II 300 V
Frequency Yes Size 23 x 19.75 x 22.2 cmHarmonicsmeasurement
EN 61000-4-7 (up to 32nd)
Type Thermal Printer Dimensions (W)95 x (D)135 x (H)55 mmInterface RS-232C Weight 440 g
Stock no. Price per OM S$ S$ S$
627-8782 unit 1+ 3060·00
Stock no. Price per OM S$ S$ S$
435-601 unit 1+ 1656·00
Stock no. Price per OM S$ S$ S$
697-3787 unit 1+ 370·00
Note: Optional individual 200A CTs are also available to give improved accuracy when monitoring low
current loads.
Accessories
Supplied with: Hawk reporter Pro software on CD-ROM,carry case,3 x 1000A current transformers, 3
x colour coded CT leads, phase probe, RS-232 cable and operators manual
Supplied with: Test lead, mains lead, 110V socket adaptor, USB/Bluetooth adaptor with driver
software on CD-ROM, 6 off rechargeable NiMH AA batteries, mains battery charger, 30-day PATGuard
evaluation disk, reference guide, instruction manual on CD-ROM, carry case.
Soft carrying case
4 flexible current probes (15 A/150 A/3000 A)
Power Log software
Voltage leads and clips
Color localization set
PC interface cable
Universal AC adapter
Printed English manual
Multi-language manual CD
Contact RS for calibration requirements
Earth Bond Test Differential Leakage
Output Current (Load 2) : ± 200mA DC Test Voltage: 230V +10%, -15% Test Voltage (o/c): > 4VDC Maximum Load current: 13A rms Test Duration: Programmable within a
maximum limit Test Duration: Programmable within a
maximum limit Measuring Range: 0.01Ω - 19.99Ω Measurement Range: 0.25 - 19.99mA Operating Error: ±5% + 2 counts Measurement Resolution: 0.01mA Measurement Resolution: 0.01Ω Operating Error: ±5% of rdg +2 digits Pass Value: User defined Pass Value: User defined Insulation Test Touch Leakage
Test Voltages: 500VDC @ 1mA nominal Test Voltage: 230V +10%, -15% Test current: >1mA into 500k.; < 2mA into
s/c Maximum load current: 13A rms
Test Duration: Programmable within amaximum limit
Test Duration: Programmable within amaximum limit
Measurement Range: 0.10 MΩ - 40MΩ Measurement Range: 0.10 - 3.50mA Operating Error: ±5% +2 digits Measurement Resolution: 0.01mA Measurement Resolution: 0.01MΩ (Max) Operating Error: ±10% of rdg +2 digits Pass Value: User defined Pass Value: User defined
Stock no. Price per OM S$ S$ S$
627-5727 unit 1+ 14501·00
Contact RS for calibration requirements
Description Stock no. Price per OM S$ S$ S$
Hawk 5000 436-471 unit 1+ 6150·00
200A ac CT 436-516 unit 1+ 245·00
RCD Test Test Current: 30mA rms sinusoidal Test Voltage: 230V +10 %, -15 % Test Current Accuracy: +10, -0 %
Selectable PASS/FAIL limits provide instant indication of a faulty asset
200 mA continuity test
250 V and 500 V insulation tests prevents damage to sensitive electronics
Instant re-start for fast testing across multiple rooms
Tests for standard, RCD-protected and anti-surge extension leads
Interrupt-time tests for portable or plug-in RCDs
Adjustable test times allow faster testing for increased productivity
Differential, Substitute or Touch leakage current tests
Operational test with VA display
a professional appearance
Print on plain paper or pre-printed forms
Extensive range of certificate formats and supports IEE, NICEIC, ECA, SELECT and ELECSA and BS
electrical test certificates
Full range of PAT testing certificates including repairs cerificates
Reports module generates a wide range of reports for electrical installation testing and PAT testing.
Project billing certificates and reports
Digital imaging module allows picture import for increased clarity in reports
Organiser module for scheduling workload, site work and retesting etc. with graphical diary
Extended forms offer alternative and extra certificate formats including filling stations and security
systems, ensuring there is a certificate to meet your requirements
Push-button operation for test groups or individual test functions
Test results are marked as a PASS or FAIL, and compared to the pass/fail limits for each test
indicating a good or marginal result
Selectable PASS/FAIL limits
Direct testing of IEC power cords with no adapter
Supplied with: Power cord, 7129 test leads, 7101 flat test bar, 7140
adapter, probe case, shoulder strap & manual
PAT320 only:
PAT410 Features:
Note: System Requirements: Pentium IV PC running XP or Vista operating system; 128MB RAM
(Min); 100MB hard disk space; CD-ROM drive; COM1 RS232 port (or USB port with USB to RS232
adaptor) for use with downloading PAT testers; Bluetooth for use with Megger MFT1553
Light weight, low current Portable Appliance Tester, configurable for fast testing and high
productivity.
230V operation & testing
Conductor Resistance Test Measuring current 2.5mA dc or less Measuring Range 0 - 15.00 Ω Accuracy ± (2% rdg +3 dgt) Resolution of measurement 10 MΩ Leakage Current Test
Open circuit voltage <12 Vac Measuring Range AC 0.1 - 19.99 mA Measuring current 10 Aac nominal value Resolution of measurement 0.01 mA Accuracy ± (3% rdg +5 dgt) Examination time Max 15s Insulation Resistance Test Accuracy ± (3% rdg +5 dgt) Rating 250 V / 20 MΩ Mains Voltage Check
Measuring Range 0 - 19.99 MΩ Measuring Range 207 - 264 Vac Resolution of measurement 10KΩ Resolution of measurement 1 V Output voltage 25 0Vdc (+20% / -10%) @ 1MΩ Accuracy ± (2% rdg +3 dgt)
Stock no. Price per OM S$ S$ S$
667-8359 unit 1+ 1090·00
10A & 25A High current test capability
Supplied with: User Guide CD, extension lead adaptor, quick-start guide, carry case and document
wallet, bond/continuity test lead with croc-clip and probe.
Description Stock no. Price per OM S$ S$ S$
Kew 6201A Aus/NZ 410-703 unit 1+ 1100·00
Kew 6201A SG ver 543-273 unit 1+ 880·00
PAT420 Features:
Bond Test (PAT320 only) Touch Current Test
Test voltage 9Vac nominal Test Voltage Mains 115/230Vac,50/60Hz
10A Test 10A rms ±20% nominal Display Range 0 → 5mA
26A Test 26A rms ± 5% nominal Accuracy ±5% ± 30μA
Display Range 0 → 1.99Ω Resolution 10μA
Accuracy ±5% nominal Operational Test
Resolution 1mΩ , 10mΩ Test Voltage Mains 115/230Vac
Continuity Test Display Range 0 → 4KVA.
Test Voltage +4.5Vdc ± 10% Accuracy ±5% nominal
Test Current ±200mA ± 10% Resolution 1VA � 10VA
Display Range 0 → 19.99Ω Displays Load VA, voltage and current
Accuracy ±5% nominal Extension Lead Test
Resolution 1mΩ, 10mΩ Tests Insulation and Bond tests
Insulation Test Polarity Test Lead OK; LN S/C;
Test Voltage 250Vdc, 500Vdc nominal LN Reversed; L/N O/C
Display Range 0 → 100MΩ Portable RCD test
Accuracy ±2% , ±5% nominal Test Current Accuracy -8% to –2% (½ x I)
Resolution 10KΩ, 50KΩ +2% to +8% (1 x I, 5 x I)
Substitute Leakage Test Trip Time Display Range 0 → 1999ms (½ x I)
Test Voltage 40Vac ±5%, 50/60Hz 0 → 300ms (1 x I)
Display Range 0 → 19.99mA 0 → 40ms (5 x I)
Accuracy ±5% ± 100μA Accuracy ±1% ± 5 digits
Resolution 10μA Resolution 100μs
Differential Leakage Current Fuse Test
Test Voltage 115/230Vac, 50/60Hz Display OK, Open Circuit
Display Range 0 → 19.99mA
Accuracy ±5% ± 100μA
Resolution 10μA
Dual 230V and 110V operation and testing for industrial, commercial and residential applications
10A and 25A bond test with high duty cycle and no overheating on repetitive tests
Description Stock no. Price per OM S$ S$ S$
PAT320 BS1363 712-5755S unit 1+ 1952·00
PAT450 Features:Dual 230V and 110V operation and testing for industrial, commercial and residential applications
10A and 25A bond test with high duty cycle and no overheating on repetitive tests
Flash test at 1.5kV and 3kV, ideal for industrial, tool hire and service workshops
Accessories
Supplied with: User Guide CD, extension lead adaptor, quick-start guide, carry case and document
wallet, IEC C6 to C13 plug adaptor, bond/continuity test lead with croc-clip and probe, High Voltage
0.00 → 20.00 Ω/0.01 Ω Test voltage /current 250 → 500 V (in 10V steps)>1 mA DC
Max. test current/voltage > 10 A / > 4 V AC Residual voltage measurementrange
0.0 → 400 V AC/DC
Protective earth resistance(0.2A)
0.00 → 4.00 Ω/0.01 Ω High voltage test voltage/current
1000V / 50mA AC
Test Current/Voltage > 0.2 A / > 4 V AC Trip current 5, 10, 25, 50mA (adjustable) Loop/Line Impedance 0.00 → 20.00 Ω/0.01 Ω Power Supply 230V +10%/-15% 50 Hz, max.
100 VA Test current 20 A (10ms) @ 230V Dimensions & weight 340 x 310 x 170 mm: 7kg
Supplied with: Test leads, carry case and comprehensive user
MIT520/2 additional features
instructions.
Stock no. Price per OM S$ S$ S$
700-7806S unit 1+ 3610·00
Pre-programmed tests: PI, DAR, SV(Step voltage),
Dielectric Discharge (DD) test for multilayer insulation, ideal for detecting cavities in generator &
motor armature windings
Selectable audible alarm points indicates when required insulation level is attained – saving test
time in production & repetitive testing applications.
Selectable breakdown or burn mode
Real time data output-RS232 and USB
32kB data storage
Download software using Megger Download Manager (supplied)
Variable test voltage and time intervals
Note: Please contact RS for calibration requirements
Earth Continuity Load Current 13A maximum Test Current ±200mA DC Test Duration 30s maximum user controlled Test Duration 60ms nominal Pass Value 3.5mA ± 0.2mA Class I
0.25mA ± 0.05mA Class II Pass Value 0.2Ω IEC Lead Test
Insulation Resistance Test Voltage 7V nominal Test Voltage 500Vdc Test Duration 2s nominal Test Current 1mA into 500kΩ 2mA short circuit Test Earth Continuity
Insulation ResistanceLive, Neutral Continuity and Polarity
Test Duration 2s nominal Power Socket Test
Pass Value 2 MΩ Input Voltage Range 230V ±10% - 15% AC Differential Leakage Voltage Indication Phase to Earth Voltage
Phase to Neutral VoltageNeutral Earth
Test Voltage 230V ± 10%
Accessories
Supplied with: 3m test lead set, USB & RS232 download leads (MIT520/2 only) and Download
Manager software (MIT520/2 only) user guide.
Test Voltages dc 250V, 500V, 1kV, 2.5kV, 5kV and 10kV (Fluke 1555 only)-0%, +10% at 1mA load current
with 100MΩ load Interference rejection 2mA rms @200V and above
Display range Digital display 10kΩ to 35TΩ;Analogue display 100kΩ to 1TΩ
Timer range Counts up to 99 minutes from startof test
Short circuit/chargecurrent
3mA Dimensions 305 x 194 x 360 mm
Capacitor charge time ≤5 seconds per μF at 3mA Weight 7.1 kg Capacitor dischargetime
≤250ms per μF to discharge from10000V → 50V
Pulse characteristics
Width 7nS to 2μS selected according to range, nominally 8% of range Amplitude 5V nominal when unterminated Output impedance 25Ω, 50Ω, 75Ω, 100Ω, switchable Output 2 x 4mm on 19mm pitch Protection Instrument will not be damaged by direct applications of 250V a.c. rms 50/60Hz to the input.
For safety reasons, however, it should NOT be operated under these conditions. For safe useon cable carrying hazardous live voltages, the blocking filter test lead must be used.
Display LCD 128 x 64 pixels with back light Cursor Single vertical line Modes
Real time Single trace cable type select (sets pvf default gain algorithm & impedance) screen contrast,with automatic temperature compensation Units - meters or feet pvf adjustment
Power 6AA size LR6 batteries Operating temperature -20 to +55°C Dimensions 250 x 100 x 95 mm Weight 0.6 kg
Ranges (nominal) 10m, 30m, 100m, 300m, 3000m at a pvf of 0.67 Accuracy Better than 0.9% of range Resolution 1% of range Propagation velocity Variable 0.2 to 0.99 pvf Gain Automatic (varied across screen)
L810/3/PWR - LV power cable
L810/3/50- Coax LAN cable, cellular, TV & satellite antennae, 50Ω
L810/3/75 - Coax CATV, 75Ω
L810/3/100-telecoms and data comms twisted pair cable,100Ω
L810/3/BNC- F-BNC & BNC to F outlet adaptor
Ranges (nominal) 10m, 30m, 100m, 300m, 3000m at a pvf of 0.67 Accuracy Better than 0.9% of range Resolution 1% of range Propagation velocity Variable 0.2 to 0.99 pvf Gain Automatic (varied across screen) Pulse characteristics Width 7nS to 2μS selected according to range, nominally 8% of range Amplitude 5V nominal when unterminated Output impendance 25Ω, 50Ω, 75Ω, 100Ω, switchable Output 2 x 4mm on 19mm pitch Protection Instrument will not be damaged by direct applications of 250VAC rms 50/60Hz to the
input. For safety reasons, however, it should NOT be operated under these conditions.For safe use on cable carrying hazardous live voltages, the blocking filter test leadmust be used.
Display LCD 128 x 64 pixels with back light Cursor Single vertical line Modes Real time Single trace cable type select (sets pvf default gain algorithm & impedance) screen
contrast, with automatic temperature compensation Units - metres or feet pvfadjustment
Power 6AA size LR6 batteries Operating temperature -20°C to +55°C
Type Insulation Resistance Tester Safety EN 61010 safety rating CAT IV 1000 V, CAT III 1000 V Display Type LCD with analogue bargraph
Stock no. Price per OM S$ S$ S$
712-5774 unit 1+ 8095·00
Stock no. Price per OM S$ S$ S$
669-9552 unit 1+ 2250·00
Manu. Part No. Stock no. Price per OM S$ S$ S$
10/L810/3/50 339-8293 unit 1+ 73·50
Description Stock no. Price per OM S$ S$ S$
Fluke 1550 5kV Tester 705-1957S unit 1+ 5124·00
Fluke 1550 5 kV Tester Kit 705-1951S unit 1+ 5773·00
Fluke 1555 10kV Tester 705-1960Sa unit 1+ 6353·00
Fluke 1555 10 kV Tester Kit 705-1963S unit 1+ 7074·00
Accessories
Description Stock no. Price
per
OM S$ S$ S$
L810/3/PWR test lead for powercable
339-8287 unit 1+ 370·00
L810/3/75 test lead for 75Ωcoax
315-8332 unit 1+ 86·50
L810/3/100 test lead for 100Ω t/pair
339-8300 unit 1+ 86·50
L810/3/BNC-F BNC to F Adaptor 339-8322 unit 1+ 73·50
Can be used on de-energized /energized circuits from 0-600V AC/DC
Live cable tracing without tripping RCDs
Indicates presence of AC/DC voltage
Meets EN61010 CAT III 1000V safety rating
Supplied with 3 AA alkaline batteries
Standards: EMC: EN 50081-1 and EN 50082-1, EN61010-1:2001
Description Stock no. Price per OM S$ S$ S$
2042 Cable Locator Kit 513-1799 unit 1+ 1357·00
2042T Additional Transmitter 513-1812 unit 1+ 662·00
Supplied with: Carry case & 9V battery
RC-954 receiver
Specifications Voltage range: 100 V to 250 V for ECB50-E
Power consumption: Approx 1 W
Transmitter Frequency range: 50 to 60 Hz for ECB50-E
Transmission frequency: Approx 8 kHz
Receiver Transmitter frequency: Approx 10 Hz
Tracing depth Approx 0 to 10 cm
for fuse identification: (4 in) depending on local conditions.
Tracing depth for Approx 0 to 40 cm
cable location: (15 in) depending on local conditions
Transmitter General Specifications
Operating temperature range: -10 °C to 40 °C max 80 % R.H.
Dimensions: 70 x 55 x 86 mm
Weight: Approx 65 g
Receiver General Specifications
Sensitivity setting Using On/Off control
Low battery indication 7.5 V
Switching fuse/cable Manually using Fuse-Line switch
Operating -10 °C to 40 °C
temperature range max 80 % R.H.
Dimensions: 22 x 162 x 34 mm
Weight: Approx 100 g
Power supply 9 V battery, IEC 6LR61, Alkaline only
Applicable directives EMC: EN 50081-1 and EN 50082-1 and standards
Transmitter: Low battery indication 7.5V Operating temperature range-10 to 40°C at max. 80% RH Switching fuse/cable manually using Fuse-Line
switch Overvoltage category CAT III 150 V Operating temperature range-10 to 40°C at max 80% RH Pollution degree 2, Protection Class: IP20 Overvoltage category CAT III 300 V Size and weight 70 x 55 x 86 mm, 65g Pollution degree 2, Protection Class: IP20 Receiver: Power Supply 9 V battery, IEC 6LR61, Alkaline
only Sensitivity setting Using On/Off control Size and weight 22 x 162 x 34 mm, 100g
Manufactured from clear impact resistant PVC, the RS Australian and
New Zealand plug-in mains socket tester is designed to ensure
personal and equipment safety.
Motor rotation and rotary field indicator with contact-free detection
Indication of the three phases via LCD
Indication of the phase rotation direction via LCD
Swift determination of the phase sequence in three-phase networks
Voltage and frequency range suitable for industrial systems
LC-display with good visibility in bright areas (i.e. outdoor)
Fused test probes (500mA 1000V fast acting)
Logical green for go indication shows good wiring status - 3 green
LEDs indicate good wiring status
Detects 18 faulty wiring condition
Continuous audible tone indicates correct wiring
Strong warbling tone indicates incorrect wiring
Audible fuse finding facility
This indicator will prove continuity, or identify fault condition, of all
Socket TesterThe green neon will light if the socket tested is wired correctly. The
For 3-phase socket outlets, this indicator will instantly verify connection,
or identify non-connection, of all three lines and shows the sequence of
phase rotation. To ensure the correct and safe operation of 3-phase plant
with motors turning in the expected direction, it is fitted with a red 16 A, 4-
pin, 3-phase and earth BS4343 plug.
As with the Martindale classic check plug, this is a fast and easy way
to test 13A sockets. Also incorporates audible indication of correct
wiring for hard-to-locate sockets and can be used as a basic fuse
finder.
Rotary field Indicator – indication of the three phases via LED
Motor rotation Indicator - display of motor rotation direction
Contact free determination of the rotation direction of running motors
Swift determination of the rotary field as for conventional rotary field indicators
Magnetic field detection to detect AC solenoid valve
Contact-free determination of rotation direction of running motors.
Ideal if motor shafts are not visible or difficult to access. (i.e. circulating pumps)
Voltage free and safe detection of three phase motor connectors .
Indicates the motor rotation before starting the motor
Fused test probes are 500mA 1000V fast acting
three lines and shows the sequence of phase rotation. It’s a fast, effective
method of identifying worn or unmarked cables and ensures 3-phase outlets and
machines are wired correctly.The retractable GS38 probe shields give a choice of
long, exposed tips for inaccessible contacts or safer, shorter lengths for
increased safety.
Fast and safe indication of socket wiring
Three neons show wiring status
Incorporates audible indication of correct wiring
Fuse and trip finding, located when buzzer stops
Flame retardant ABS housing
The simplest, safest and most efficient
method of checking 16A 2P+E BS4343
sockets
Intended for use on industrial 240V
sockets whilst the 110V check plug will
check centre tapped 110V supplies
Both the 110V and the 240V Check
Plug are fitted with a standard BS4343
orange neon will light if there is a fault, i.e. missing earth or reversed polarity.
Contact RS for calibration requirements
With Non-Trip Earth Loop Impedance, Polarity
& RCD check
Indications include:
Supplied with: key/belt ring.
Voltage 240 V ac Earth Loop Impedance Test No Wiring Checked Yes Audible Tone Yes
16A plug
Fault conditions displayed on three neons on the 240V checker and on three LEDs on the 110V unit
Both Check Plugs list fault conditions and their associated indications on the face of the unit
Supplied with: 4-pin 16 A plug, instructions
Live - earth reverse
Live - neutral reverse
Faulty, neutral, earth and live
Missing live
Weight 200 g
Operational check of 30mA RCDs
Supplied with: 3 fused test probes, 3 crocodile clips, instruction
manual.
Overvoltage Cat. CAT III 600V Voltage Range 100 to 600 VFrequency Range 40 to 60Hz
Contact RS for calibration requirements
Stock no. Price per OM S$ S$ S$
719-0891S unit 1+ 48·90
Tests for total supply system polarity safety
Bright LED’s indicators with logical Green for Go LED Indication
Detects good plus 17 wiring fault conditions
Clear indication of where the actual fault is - Live, Earth or
Neutral
Continuous or strong warbling tone gives positive quick
indication of good or faulty wiring
Colour LED read out shows earth loop impedance result as
Good, Check or Urgent Check; Good when less than 1.8Ω
Built-in self check
Approvals: Australian Standards Approval number CS900020.
Supplied with: One fused crocodile clip, two fused prods with retractable GS38
shrouds, instructions
Voltage Range 40 to 700 V Measurementcategory
CAT III, 600 V / CAT IV,300V
CurrentConsumption
approx. 1 mA @ 700 V Safety Complyingwith
IEC61010 / EN61010,IEC61557-7 / EN61557-7
Frequency Range 15 to 400 Hz
SOK ADP40 Converts S0K40/16 into a 32A tester
16A socket to 32A plug
Stock no. Price per OM S$ S$ S$
254-308S unit 1+ 165·00
Note: High sensitivity RCDs or excessive earth leakage currents may
cause inadvertent tripping of the circuit during loop check. Always
Stock no. Price per OM S$ S$ S$
467-4964 unit 1+ 80·00
Stock no. Price per OM S$ S$ S$
424-585S unit 1+ 220·00
Stock no. Price per OM S$ S$ S$
780-059 unit 1+ 35·90
Pins 3 Wiring Checked Yes Audible Tone No
Description Stock no. Price per OM S$ S$ S$
Fluke 9040 513-1828S unit 1+ 467·00
1000V 500 mA Fuse 388-4132 unit 3+ 5·30
check prior to use where loss of supply may be hazardous or unacceptable.
This unit is an indicator only and is not designed to provide readings for completing certificates
Supplied with: 3 Fused test probes, 3 pc Crocodile clips,3 pc Test leads 9 V PP3 battery, Protective
Holster and Instruction manual
Description Stock no. Price per OM S$ S$ S$
240V - Blue plug CP201 253-535S unit 1+ 53·50
110V - Yellow plug CP301 253-541S unit 1+ 72·00
Voltage 230V
Wiring Checked Yes
Earth Loop Impedance Test Yes
30mA RCD test Yes
Polarity Test Yes
Audible Tone Yes
Voltage Range 1400 Vac Measurement category CAT III / 300 V Phase Display 120 - 440 Vac Protection Degree IP 40 Frequency range 2400 Hz Safety Complying with IEC61010 / EN61010, IEC61557-7 / EN61557-7 Test Currents < 3.5 mA
Voltage testers with or without resistance measurement facility
An essential safety aid that is widely specified by training
LED voltage Indication
Illuminated test probe
Continuity testing with audible buzzer for continuity and voltage
Phase sequence testing
>90Vac Single Phase Test
Line powered LED indicates 50V-120Vac/dc even without batteries
Supplied with 2 x AAA batteries 591-657 (upto 1500 hours operation)
IP50 enclosure
Safety approved in accordance to EN61243-3 and VDE 0682 Part 401
A handheld, battery powered proving unit able to provide a nominal 240Vdc,
2mA source to prove the integrity of neon type test voltage indicators
For safety, voltage indicators should be checked for correct operation from
this known voltage source before and after every use
The unit is housed in a compact ABS plastic case and fitted with a belt clip for
convenience
An LED is used to indicate battery condition
Digi check 3.2 with AC/DC range and continuity test on a 2000 count LCD
display, with back light.
2-pole tester with LED
12 to 690V a.c./d.c voltage indication range
Diode/ Continuity test with visual and acoustical indication
Integrated single pole test for phase detection
Rotary field indication
IP65-water-jet and dust-tight protection for outdoor use
Electrical torch function for working in dark environments
Automatic, internal load for tripping out 30mA RCD’s
Quick response time (<0.1s) for fast voltage tests
Battery test function
Probe-tip protection permanently attached to lead
Complies with GS38 with regard to probe tip construction (less than 2mm of exposed
metal tip)
Fully operational voltage indication even when batteries are discharged or when no
Two filament test lamps giving safe indication of voltages
between 150V and 500Vac/dc. Their robust design meets the
recommendations of the Health and Safety Executive in
their guidance notes on electrician’s test lamps (GS38)
LED voltage Indication
Line powered LED indicates 50 to 120Vac/dc even without batteries
2 pole tester with LED and 3½ digit LCD 1999 count display
12 to 690V ac/dc voltage indication range
Diode/continuity test with visual and acoustic indication
Integrated single pole test for phase detection
Rotary field indication
IP65 protection for outdoor use
Integral torch
Automatic, internal load for tripping out 30mA RCDs
Quick response time (<0.1s) for fast voltage tests
Battery test function
Probe-tip protection permanently attached to lead
Stock no. Price per OM S$ S$ S$
481-2116 unit 1+ 83·50
0 to 100Hz (ac >2Hz) frequency range
IP50 enclosure
Safety approved in accordance to EN61243-3 & VDE 0682 Part 401
Supplied with 2 x AAA batteries (upto 1500 hours operation), see RS Stock
no. 591-657)
Automatic range selection
Illuminated measuring probes
Audible buzzer on continuity test
Display hold function
Polarity (+/-) check
Single pole phase testing
Transistor check
Battery Low indicator
Battery and function test
batteries are fitted
Complies with EN61243-3 and EN61010-1
Input protection to EN61010-1 CAT IV 600V
Note: This product will only work with test voltage indicators that have an input
impedance of greater than 120kΩ.
organisations, utilities and large contractors. This GS38 compliant voltage indicator
rapidly and safely checks if a circuit is live, its voltage range and AC and DC voltages
from 50V to 600V.
Tough, moulded case
Double insulated leads
Probe tip contains finger guard and lockable, retractable prod sheath
Probe incorporates a 500mA HRC fuse
Stock no. Price per OM S$ S$ S$
242-4111S unit 1+ 146·50
Automatic on/off to save battery life
Norm: VDE 0682 part 401 / EN/IEC 61234-3
Electrical version complies to HSE GS38 recommendation with less
Complies with GS38 with regard to probe tip construction (less than 2mm of exposed metal tip)
Fully operational voltage indication even when batteries are discharged or when no batteries are
fitted
Complies with EN61243-3 and EN61010-1
Input protection to EN61010-1 CAT IV 600V
Resistance measurement up to 1999Ω (T140 only)
Backlight (T140 only)
Contact RS for calibration requirements
Input Current Is <2.5mA at 690V Input Impedance ≥300 kΩVoltage Surge Proof 6kV Continuity Check Yes Voltage Range 6 → 690 Vac/Vdc Frequency Range 0 → 100 Display Type LED
than 4mm of exposed metal tip
Standard version has probes with 15mm exposed tips
Powered by 2 x AAA batteries (not supplied)
Surge proof to 6kV
Contact RS for calibration requirements
Input current Is <2.5mA at 400V Input Impedance 265 kΩVoltage surge proof 4kV Continuity Check Yes Voltage Range 6 → 400 Vac/dc Resistance RangesDisplay Type LED Frequency Range 0 → 100 Hz
Supplied with: Instruction leaflet & batteries.
Stock no. Price per OM S$ S$ S$
621-1155S unit 1+ 116·00
Supplied with: Instruction leaflet & batteries
Supplied with: Instruction manual.
Stock no. Price per OM S$ S$ S$
410-0104S unit 1+ 66·50
Display 12, 24, 50, 120, 230, 400, 690V LED bargraph Continuity range 0 → 400kΩVoltage range accuracy ±(3% rdg +3 digit) Power supply 2 x AAA (IEC LR03) supplied Continuity/ Diode test Optical (LED) / acoustical Operating Frequency 0 - 400 Hz
Supplied with: Operating instructions.
Description Stock no. Price per OM S$ S$ S$
T100 502-5694S unit 1+ 564·00
T100, Aus version 516-6290 unit 1+ 110·50
Voltage Range 0 to 600 V Continuity Check No Display Type LED
Voltage Range 5 to 690 Vac/dc Continuity Range 0 to 500 Input Impedance >600 kΩ Display Type LCD
Display 3½ digit LCD , 1999 count and 12, 24, 50, 120, 230, 400, 690V LED bargraph Voltage range accuracy ±(3% rdg +3 digit) Operating frequency 0 to 400Hz Resistance Measurement Up to 1999Ω (T140 only) Continuity/ Diode test Optical (LED) /acoustic Continuity range 0 to 400kΩPower supply 2 x AAA (IEC LR03) supplied
Accessories
Stock no. Price per OM S$ S$ S$
719-0882S unit 1+ 118·00
Stock no. Price per OM S$ S$ S$
493-4200 unit 1+ 230·00
Description Stock no. Price per OM S$ S$ S$
T120 502-5701S unit 1+ 172·00
T120 516-6307 unit 1+ 195·50
T140 721-5385S unit 1+ 240·00
T140 516-6313 unit 1+ 224·00
C33 Carry Case 502-5723 unit 1+ 49·90
Description Stock no. Price per OM S$ S$ S$
C33 Carry Case 502-5723 unit 1+ 49·90
TP38 Slender Probes 384-8265 unit 1+ 28·80
AC285 Large Alligator Clips 451-1431 unit 1+ 36·40
Supplied with: Nylon carry case with belt loop and instructions.
Note: Will NOT detect cables behind buried plaster, buried trunking etc. and will not detect output
from safety isolation transformers with earthed secondary centre tap. The unit should be checked for
correct operation using a known voltage before use.
Supplied with: 2 x AAA batteries and instructions.
Group & Category: II 2 G EEx ib IIC T4
Stock no. Price per OM S$ S$ S$
719-3017S unit 1+ 84·00
Description Stock no. Price per OM S$ S$ S$
Small Test Screwdriver 544-853 unit 1+ 1·50
Large Test Screwdriver 549-448 unit 1+ 1·90
110V model 230V model
Power supply 2 x 1.5V AAA alkaline batteries (supplied)
Sensitivity (50Hz) 230 VAC Operating temp: -10 °C → +50 °C Power supply: 2 x AAA (LR03) batteries Dimensions & weight 146 mm x Ø max 22mm : 40g
Sensitivity (50Hz∼) illuminate at 4mm from wire 90V 220V Temperature -20 → +50 °C Response Instantaneous
Forked tip cable capacity 4.5mm diameter Operating temperature -20 °C → +50 °C Operating frequency 50Hz Over-voltage CAT III 1000V Power Two AAA (LR03) batteries (supplied)
Power supply 2 x 1.5V AAA alkaline batteries (supplied) Sensitivity (50Hz∼) illuminate at 4mm from wire 220V Operating temperature -20 → +50 °C Response instantaneous
Description Stock no. Price per OM S$ S$ S$
Volt-Stick Indicator 230V 214-467 unit 1+ 42·90
Volt-Stick Indicator 110V 238-3571 unit 1+ 42·90
Stock no. Price per OM S$ S$ S$
167-645 unit 1+ 39·30
Voltage Range (V(ac)) Stock no. Price per OM S$ S$ S$
Many more leading brands from over 2,500 suppliers available online
Car Voltage Tester
Non-Contact Voltage andMagnetic Indicator MartindaleTEK200
Unitest MAGNO-VOLTfix
Magnetic Field Indicator / Solenoid Tester
Intrinsically-Safe Magnetic Field Indicator
PTS100/200 - Pair Tracing Kit
LVD2 Volt Light
Non-contact AC voltage detector and LEDflashlight
Fluke 1AC Voltage Detector
Tester for automobile electric and electronic circuits. Its low
power consumption of 1.5mA is suitable for locating faults
in electronic components where conventional lamp testers
may cause damage. It has a crocodile clip on one end, and a
tester with LED display and probe tip. The bright LED display
indicates voltage and polarity. Particularly suitable for
trouble shooting in wiring harnesses with catch hook to
reach any wire and a pricking needle to probe through the
insulation.
Fluke VoltAlert� - Suitable for non contact detection of AC
voltage from 90 to 1000Vac.
The next generation VoltAlert� AC non-contact voltage
testers from Fluke are easy to use — just touch the tip to a
The tip of the Magnet Stick lights up when in the presence of
a magnetic field. It responds to all kinds of magnetic fields
from alternating current to direct current and permanent
strong magnets.,A small test magnet is housed in the cap of
the Magnet Stick to check that it is working correctly.
Contact-free, optic and acoustic detection of AC voltages
Magnetic field detection
Precise detection of line interruptions in open installed
cables
Compact, pen style construction
H.140 W.24 D.20mm Wt. 50g
Bright white flashlight illuminates working area
Blue indicator means you’re close
Red indicator means you’re at the source
Detects voltage from 40Vac to 300Vac upwards
Comes with versatile clip to secure light to a pocket, hat or even a
panel door
Operating temperature 0 °C → +50 °C
Ultra bright white LED with 100000 hour bulb life
AAA battery included"
Non-contact AC voltage detector and LED flashlight
combined into one easy to use pen-style design. The LVD2
is a CAT IV 600 V rated non-contact detector that is suitable
for commercial and industrial applications. The LVD2
includes dual sensitivity indication, showing blue when 1”
to 5” (2.54 cm to 12.7 cm) from the source and turning red
when at the source.
The PTS Pair Tracing System comprises the PTS 200 Tone
Generator and the PTS 100 Probe in a woven polyester
carrying pouch. The System is designed to provide an easy
to use and cost effective means of tracing wire pairs
A non-contact voltage indicator with the additional ability to
detect magnetic fields.,Suitable for indicating the operation
of solenoid valves in pneumatic and hydraulic control
equipment, and testing relays or solenoids in a wide range
of vehicle and machine controls.
Input voltage 3-48Vac/dc Voltage display 2 LEDs
Standards: CAT IV 600 V
Approved for use in hazardous areas
The tip of the intrinsically safe magnet stick
lights up in the presence of a magnetic field
Responds to all kinds of magnetic field from
alternating current and direct current and
permanent strong magnets
Fast, Accurate Wire Identification
Sends Tone to Identify Wires
Polarity Indication
Continuity Test
Adjustable Volume Control
Easy to Operate
2-Line Modular Test Lead
Note: This unit uses a magnetic read switch sensor. For applications requiring more sensitivity we
recommend stock No. 254-099 which uses a Hall Effect sensor.
terminal strip, outlet, or supply cord. When the tip glows red and the unit beeps, you know there’s
voltage present. Electricians, maintenance, service, safety personnel, and homeowners can quickly test
for energized circuits in the workplace or at home.
Display 2 LEDs Safety IEC 1010, EN 61010 Voltage Range 50 to 600Vac Overvoltage Cat. CAT III/600V Frequency Range 50 to 500Hz Pollution Degree 2Magnetic Sensitivity >25mT Power Supply 2 x AAA (IEC LR03) supplied
Stock no. Price per OM S$ S$ S$
225-3335 unit 1+ 32·40
Avoids the need for a separate proving unit
Tests relays, contactors and solenoids without
Stock no. Price per OM S$ S$ S$
493-3241 unit 1+ 43·40
Supplied with: AAA battery
Supplied with: Batteries fitted and an instruction leaflet.
Stock no. Price per OM S$ S$ S$
374-1849 unit 1+ 122·50
Supplied with: 2 x AAA alkaline batteries (stock No. 591-657) and integral test magnet.
Rugged Industrial design
Water Resistant
disconnecting them from circuit
Senses AC voltages from 100 to 600V by detecting the electrical field
Determines and displays polarity of magnetic fields
Self test facility ensures correct functioning
The self test circuit transmits a 50 Hz signal to the voltage or magnetic sensor to fully test the
integrity of the internal circuitry
Powered by PP3 battery (stock No. 394-9059)
Tip glows red when a voltage is detected
Pocket sized
Batteries included
Description Stock no. Price per OM
Fluke 1AC Voltage Detector 462-8545 unit 1+ 48·00
Fluke 1AC-II Voltage Detector 255-073 unit 1+ 48·30
PTS 200 Tone Generator:
Voltage Range 100V to 600Vac 3 mm at 110Vac 50Hz Voltage SensitivityDistance from a flat PVC 1 mm<sup>2</
sup>
twin and earth cable suspended in freespace:
23 mm at 240Vac 50Hz
Voltage IndicationRed LED and audible tone (3 kHz) in thepresence of an AC voltageGreen LED internal battery condition
Green LED south pole
Frequency Range 50Hz to 50kHz (voltage) Frequency Range 0 to 50kHz (magnetic) MagneticSensitivity
±10 mT Operating Temp. -5 → +40 °C
MagneticIndication
Red LED north pole Case Material ABS
Group & Category: II 2 G EEx ib IIC T4
Stock no. Price per OM S$ S$ S$
255-061 unit 1+ 60·90
Stock no. Price per OM S$ S$ S$
375-5422 unit 1+ 62·50
Stock no. Price per OM S$ S$ S$
719-0876S unit 1+ 117·00
Description Stock no. Price per OM S$ S$ S$
Magnetic field indicator, ATEX 457-8311 unit 1+ 101·50
Magnetic field indicator, IECEx 166-800 unit 1+ 96·00
The PTS 200 may be connected via the modular plug or the crocodile clips to the pair under test.
Depending on the switch position the Tone Generator will test Polarity continuity or short circuits.
The PTS 200 can be used on twisted pair wiring (Telecom, Datacom, security / alarm, audio and
electrical), single conductors, coaxial cables, de-energized AC wiring and just about any other
wiring you can think of.
PTS 100 Probe:The PTS 100 Probe has a built-in loudspeaker to make it easy to hear the tracing signals and a near/
far sensitivity Adjustment to allow both broad searches and pinpoint identification of wires. To
operate just press the button on the top and adjust the sensitivity control to hear the tone
generated by the PTS 200
Note: Only for use on non-powered cables, powered by PP3 batteries (not supplied).
The Model 701K is recognised by technicians as the industry
standard for wire and cable identification. The kit is used for
the identification of single conductors or cables within a
bundle, at a cross connect point or at remote ends. Supplied
in a sturdy woven polyester carrying case the 701K kit
comprises the 77HP High Power Tone Generator and the 200
EP Inductive Amplifier
IntelliTone� digital signal locating technology is the smarter,
faster way to locate all hidden and hard-to-find cables. LED and
Designed to make cable identification and connector tracing easier.
Rugged, battery operated, handheld LAN tester to identify cable failures
UTP, FTP and coax cabling tests
Category 5 cabling
End to end EIA/TIA 568 verification
Detects opens, shorts, mis-wires, crossed pairs, reversals and split pairs
Distance to fault location
Measures cabling length
One button test mode
Easy to read LCD display
Low battery and auto power off
99 data set memory
Identifies up to 8 different cables with cable identifiers
Can be used for cables between 1m and 350m
Faults detected: opens, shorts, reversed, crossed and split pair
Breakthrough IntelliTone� digital signal technology finds
cables other toners/probes can’t. Speeds cable location with
For toning and tracing wire on non-active networks and
specifically for identifying individual pairs with SmartTone�
technology. Angled bed-of-nails clips allow easy access to
individual wires and the RJ11 connector is ideal for use on
telephone jacks. The large loud speaker on the probe allows
you to hear through drywall, wood or other enclosures to find
wires quickly and easily. Tone signal can be sent up to 10
miles on most cables. External switch on generator allows
selection of solid or alternating tone options, indicated with
solid or flashing LEDs. Probe has adjustable volume dial
control and "quick-twist" tip for easy replacement.,Free spare
tip with "Pro3000 Tone and Probe Kit".
Fast, Accurate Wire Identification
Sends Tone to Identify Wires
Two Distinct Tone Signatures
Stock no. Price per OM S$ S$ S$
462-9267 unit 1+ 500·00
These easy-to-use testers are the
equivalent of a three-in-one tool
kit: a fault locator, a cable and
wire manager and a tone
generator with SmartTone�
technology.
advanced sensing modes. Simplified signal interpretation with smart LED
and audio indicators.
audio indicators simplify cable isolation. Works with all industry-standard tone generators.
Frequency 1000 HzTone Yes
Polarity Indication
Continuity Test
Talk Battery supply
Adjustable Volume Control
Visual and Signal Strength Indication
Large Speaker for Noisy Environments
Facility for Headset/Buttset connection
Choice of Metallic or Plastic Probe Tip
2-Line Modular Test Lead
3-Colour LED identifies AC Ring Voltage
Rugged Industrial Design
The tone Generator includes:
Rejects noise and false signals
Identifies and diagnoses POTS with multi-line Telco detect, polarity and
ring indication
Audible and visual signal indication simplifies cable location in noisy
environments
Diagnoses essential cable information with polarity, continuity, and talk
battery
Safely and effectively tones active networks
Additional probes can be ordered separately
Accessories
Rejects noise and false signals using IntelliTone� digital signal technology (with
Intellitone Toner)
Locates hard-to-find cables, even on active networks
Speeds cable isolation with thumbwheel controlled sensing modes
Simplifies signal interpretation with smart audio and LED signal indicators
Extended battery life with auto power-off
Description Stock no. Price per OM S$ S$ S$
Pro3000 Tone and Probe Kit 503-568 unit 1+ 150·50
Gain 26 dB Voltage Protection (continuity mode) 52V d.c. @ 600ΩTransmitter Power 7dB @ 600Ω Talk Battery 4.5V d.c @ 600ΩWeight Including Battery 170/140 g
Works on any multiple core
(2+) cable up to 760m (TS90)
or 914m (TS100)
Instantly measures distance to
open-circuit or any fault from
one end of any cable pair
Patented SmartTone� tone
generator positively identifies
RJ11 connector, RJ45 jack and pair of alligator clips
pair
Measures cable distance on reel
Displays distance reading rather than waveform
Large LED screen
High voltage detection
Moisture-proof
One-button operation
Auto power-off after 5 minute disconnection
Validates twisted-pair installation with visual end-to-end cablemap (Intellitone 200 only
with toner)
The probe is directly compatible with Wavetek LT8000 Series LAN cable
tester’s tone generator function.
Stock no. Price per OM S$ S$ S$
370-5247 unit 1+ 235·00
In addition the IntelliTone 200 identifies, diagnoses, and troubleshoots
datacom/telecom services
The IntelliTone 200 also validates twisted-pair installation with visual
end-to-end cablemap
Supplied with: BNC to alligator clips adaptor
Description Stock no. Price
per
OM S$ S$ S$
IntelliTone 100Probe
513-6261 unit 1+ 155·00
IntelliTone 200Probe
513-6463 unit 1+ 196·00
For additional or replacement Intellitone Probes see 513-6261 & 513-6463
Traces end-to-end connections
Identifies and locates voice and data wiring and terminations
Sends and detects standard signals and checks continuity
Input Protection 250 V rms ac, continuous or intermittent Impedance Range 35 Ω to 330 Ω with auto-compensation within this range. Maximum cable length TS90 2500 feet (760m), TS100 3000 feet (915m) Minimum length Minimum non-zero reading is 2 feet (0.6m) Representative maximum cable lengths 2500 feet: CAT-5 Twisted Pair
2000 feet: 12/2 ac Wire 1000 feet: RG-6/U TV Coax 500 feet (150m): RG-174/U Coax
Length Accuracy ±2 ft for cables < 10ft, ±5 ft for cables > 10 ft and < 200 ft, ± (3% rdg + 5 ft) for cables > 200 feet
High Voltage Detection Warning occurs for AC voltage > 5Vrms Measurement Rate Maximum of 4 complete measurements per second Measurement Technology Time Domain Reflectometry (TDR)
50 Ω drive impedance, 6 V maximum pulse height. VOP (Velocity of propogation) Adjustable from -20- to -99-, retained during power off.
Default to -66- when batteries are changed. Tone Injection Typically 1 kHz at an amplitude of 80% of battery voltage. Cable Type Virtually all two or more conductor cables Power 4 x AA alkaline battery, reverse polarity protected Low battery warning Indicator flashes when battery voltage falls below 4.1V Temperature Range - Operating 0 to 55°C (32 to 131°F) Temperature Range - Storage -40 to 70°C (-40 to 158°F) Size and Weight 188 x 70 x 38 mm, 450 g
Can be used for fault location and lining up of data/speech networks
Independent operation
Calibration in dBM
True r.m.s. reading
+10 to -50dB range
Provides a d.c. patch for control signals and line hold in telecom
applications
Built-in switchable 600Ω termination
Switchable tone source built-in
Stock no. Price per OM S$ S$ S$
360-1476 unit 1+ 390·00 3+ 365·00
3-Digit Receiver Send Frequency 800Kz to 1600Hz Resolution 0-01dB Output Impedance 600Ω with d.c. path Frequency Range 100Hz to 100Hz Power Supply 9V PP3 battery supplied Receiver Terminations (1) through – 17kΩ
High monitor level
High impact resistance
High chemical resistance
Easy non slip shoulder placement
Tone/Pulse operation
Redial in Tone and Pulse
Timed Break Recall (Flash)
Polarity Check
Ground Start/ Earth Calling
Full operation at 10mA
Protection against direct battery connection
Belt clip/hanging loop
Stock no. Price per OM S$ S$ S$
252-756 unit 1+ 630·00
Crocodile Clips (not included, order separately)300mm long lead terminated by 608A UK socket and 3 crocodile clips (earth lead is 430mm).
Krone LSA Plug (not included, order separately)235mm long lead terminated by 608A UK socket and a Krone LSA plug with an earth crocodile clip.
DC Parameters 50V, 200Ω Transmission Auto gain controlMax. o/p limitation 1.4V rms.4dB octaveRoll, off above 4KHz
Max Line Resistance 4KΩ Reception Acoustic shock protectedDynamic receiver
Current Range 10mA - >90mA Cordage CW1311 cordage with 431A plug Impedance (ReturnLoss)
>16dB 300-3.4KHz Safety Cord - case insulation. >50MΩ
Protected against 50V raw batteryindefinitely Lighting inductionprotection
DSL/POTS filtering technology allows user to safely draw
The TS42 test set combines rugged DropSafe� and best-in-
class DataSafe� protection with waterproof durability, and
dial tone from a pair that is carrying voice and ADSL without
downing the ADSL service
Built-in analog tone generator for tracing and identifying
wires with a probe
DTMF digit-grabbing capability
Talk battery to supply power to non-powered (dry) pairs to
carry voice conversation
Row/column tones for single tone dialing
High voltage Lockout/Low voltage Lockout
Continual data detection in monitor mode
Amplified speaker for hands-free monitoring
Programmable phonebook stored in non-volatile memory
Speed dial (10 memories, 23 digits each)
Selectable flash and pause duration
Battery level indicator
provides powerful and versatile testing capabilities.
Superior high-impedance monitoring protects data lines
2-way hands-free speakerphone capability
Passive monitor
Over-voltage & current protection
Rugged, ergonomically designed waterproof case design for severe
weather conditions, exceeds US Mil Spec MIL-STD-810E
DropSafe� 20ft onto concrete
Top or bottom mountable, with extra large steel locking belt clip
Line-cord strain relief
Mute & polarity indication
Tone & pulse dialing
Last number redial & Speed dialing
PBX pause button
Audible ringer & Amplified speaker
Volume control levels
Hearing-aid compatible
Line and battery powered, with low battery warning
Note: This product has been safety certified for indoor use only.
Standards: Conforms to relevant European Union directives.
Electrical Current Range (Off-Hook) 10 mA to100 mA
Tone Level –3 dBm combined(typical)
DC Resistance Off-Hook 150 Ω nominal High versus Low Tone difference 2dB ± 2 dB
On-Hook >3 MΩ Memory Capacity 10 speed dial plus one last numberredial memory
AC Impedance 600 Ω nominal; 300 Hz to 3400 Hz Digit Capacity 23 digits per memory On-Hook >120 kΩ; 300 Hz to 3400 Hz Pause Duration User programmable, default 4
seconds Rotary Dial (pulse)output
Pulsing Rate 10 pps ±1 pps Hook Flash Duration User programmable, default 600 ms Break/Make Ratio 60 / 40 Automatic Speaker
Shut Off Duration User programmable, default 2minutes
Inter-digit >300 ms Battery 9V alkaline or lithium battery Interval Resistance during Break>100 kΩ
Size and Weight 254 x 96 x 107 mm, 680 g
DTMF (tone) output Tone Frequency Error ±1.5 %maximum
Electrical Return Loss >14 dB (ref 600 Ω) Tone Level –1 dBm combined (typical) DC Resistance Off-Hook 150 Ω nominal High versus Low Tone difference 2 dB ± 2
dB On-Hook >1 MΩ Memory
Capacity 10 speed-dial plus one last number redialmemory
AC Impedance Off-Hook 600 Ω nominal; 300 Hz to 3400 Hz Digit Capacity 23 digits per memory On-Hook >120 kΩ; 300 Hz to 3400 Hz Pause Duration User programmable, default 4 seconds
Rotary DialOutput
Pulsing Rate 10 pps ±1 pps Hook FlashDuration
User programmable, default 600 ms
Break/Make Ratio 60 / 40 AutomaticSpeaker ShutOff Duration
User programmable, default 5 minutes
Interdigit >300 ms Battery 9V alkaline or lithium battery Interval Resistance During Break >100 kΩ Size and Weight 200 x 68 x 40 mm, 284 g