Product Data No. MPDUS0017EA DIAGNOSTIC ULTRASOUND SYSTEM V1.0 • Efficient data management A large-capacity HDD is provided in the standard configu- ration, facilitating efficient management of acquired images. Filed images can be output via the USB port or stored on CD/DVD. DICOM is supported by the optional Advanced Data Management board. In addition, Stress Echo and the reporting function can be installed as options. OUTLINE Nemio TM MX (SSA-590A) is a compact full-digital color diagnostic ultrasound system. This next-generation sys- tem has achieved high image quality and high sensitivity using advanced technologies. • Superior imaging performance Nemio MX includes THI (Tissue Harmonic Imaging) in the standard configuration and generates high-quality B-mode images. Advanced DYNAMIC FLOW TM , which produces high-resolution blood flow images and is a feature of top- of-the-line systems, and ApliPure TM , which is compounding technology for high contrast resolution, are supported. Thus, Nemio MX provides high-end imaging performance. • Sophisticated ergonomics A 15-inch LCD monitor whose brightness has been adjust- ed appropriately for the display of ultrasound images is used in Nemio MX. The displayed images are easy-to- view and their excellent visibility is relatively insensitive to the brightness of the room. A flexible multijoint arm supports the LCD monitor, allowing appropriate positioning for operations in the standing or sitting posture to be achieved easily. A lightweight body has been achieved through the use of the LCD monitor, making it much easier to move the sys- tem around in the hospital. Functions can be assigned freely to buttons on the operat- ing panel to suit individual preferences. Also, operation protocols can be registered in advance, allowing examina- tions to be performed smoothly with simple operations (Sonoset). In addition, the B-mode image quality can be adjusted appropriately with a single operation using the IP dial or QuickScan.
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Product DataNo. MPDUS0017EA
diagnostic ultrasound system
V1.0
•EfficientdatamanagementA large-capacity HDD is provided in the standard configu-ration, facilitating efficient management of acquired images. Filed images can be output via the USB port or stored on CD/DVD.DICOM is supported by the optional Advanced Data Management board. In addition, Stress Echo and the reporting function can be installed as options.
oUtliNENemioTM MX (SSA-590A) is a compact full-digital color diagnostic ultrasound system. This next-generation sys-tem has achieved high image quality and high sensitivity using advanced technologies.
•SuperiorimagingperformanceNemio MX includes THI (Tissue Harmonic Imaging) in the standard configuration and generates high-quality B-mode images. Advanced DYNAMIC FLOWTM, which produces high-resolution blood flow images and is a feature of top-of-the-line systems, and ApliPureTM, which is compounding technology for high contrast resolution, are supported. Thus, Nemio MX provides high-end imaging performance.
•SophisticatedergonomicsA 15-inch LCD monitor whose brightness has been adjust-ed appropriately for the display of ultrasound images is used in Nemio MX. The displayed images are easy-to-view and their excellent visibility is relatively insensitive to the brightness of the room.A flexible multijoint arm supports the LCD monitor, allowing appropriate positioning for operations in the standing or sitting posture to be achieved easily.A lightweight body has been achieved through the use of the LCD monitor, making it much easier to move the sys-tem around in the hospital.
Functions can be assigned freely to buttons on the operat-ing panel to suit individual preferences. Also, operation protocols can be registered in advance, allowing examina-tions to be performed smoothly with simple operations (Sonoset).In addition, the B-mode image quality can be adjusted appropriately with a single operation using the IP dial or QuickScan.
2
SyStEM MAtrix for SSA-590A
no. unit model name remarks
1 Main unit SSA-590AIncluding color Doppler, DVD drive, THI, PW, Sector, 15-inch LCD monitor, QuickScan, Sonoset
<options>2 B-PSP & CDI-PSP/QSP kit UIQS-590A PSP for 2D/CDI, QSP for CDI
4 Reference signal kitUJUR-590A Reference signal display unit + ECG cableUJUR-592A PCG sensor
5 Transducer selector UIPS-590A Adds a 3rd transducer port. 6 M-TEE hanger kit UAEH-590A7 Footswitch kit UZFS-590A Foot SW + connector kit for Main unit.8 Gel warmer UZGW-590A9 Data Management unit UIDM-590A Data Management unit with filing, DICOM storage, and report functions
10 Premium kit UIUG-590AAdd QSP/PSP, 3rd transducer port, CW, Reference signal unit, Dynamic Flow and Directional Color Angio.
11 CV kit UICV-590A ECG, CWD (without pencil transducer support).12 Cable for printer UZCA-590A For digital printers
13 Mecha 4D kit UIMV-590AEnables OB 4D scan using PVM-375MV. UIDM-590A, UIPS-590A, and UIQS-590A are required.
14Mounting kit for peripheral unit (for a single unit)
UZRI-590A For mounting a color printer or DVD recorder (with cables)
15Mounting kit for peripheral unit (for 2 units)
UZRI-591A For mounting a color printer and a DVD recorder (with cables)
<optional software>16 DCA kit USDA-590A Enables directional display in Color Angio mode (Directional Color Angio).17 Trapezoid scan kit USTS-590A Enables trapezoid scan function.18 HPRF kit USHP-590A Enables High PRF PW Doppler.19 TDI kit USTD-590A20 CHI/FEI kit USHI-590A
21 TIC kit USTI-590AEnables Time-Intensity Curve generation. USHI-590A is required.
*1: UIQS-590A is required for THI.*2: UIDM-590A, UIPS-590A, UIMV-590A, and UIQS-590A are required. Only for 3rd port.*3 Premium kit and CV kit (UICV-590A) or UICW-590A is required.*4 These transducers are no longer available for purchase. The transducers at the customer sites can still be used.
4
block chArt SyStEMS
A
Nemio MX
Main unitSSA-590A
Reference signal kitUJUR-592A
Footswitch kitUZFS-590A
Gel warmerUZGW-590A
HPRF kitUSHP-590A
A
TDI kitUSTD-590A
Mounting kit for peripheral unit
(for a single unit)UZRI-590A
Mounting kit for peripheral unit
(for 2 units)UZRI-591A
ACM kitUSAC-590A
CHI/FEI kitUSHI-590A
DICOM system kitUDDS-590A
Stress Echo kitUDSE-590A
M-TEE hanger kitUAEH-590A
TIC kitUSTI-590A
Reference signal kitUJUR-590A
Transducer selectorUIPS-590A
DCA kitUSDA-590A
Panoramic View kitUDPA-590A
B-PSP & CDI-PSP/QSP kitUIQS-590A
CW kitUICW-590A
Trapezoid scan kitUSTS-590A
Data Management unitUIDM-590A
USDF-590ADynamic Flow kit
Mecha 4D kitUIMV-590A*
4D transducerPVM-375MV
* UIQS-590A and UIPS-590A are required.
5
MPDUS0017EA
•Imageprocessing: 5IPtypesareavailable. The following parameters can be controlled.
– Dynamic range: 30 to 100 dB (can be set inde-pendently for 2D and M)
– Edge enhancement: OFF, 1, 2, 3– Automatic gain control: 4 types– Postprocessing: 2D, 8 types– Temporal smoothing: OFF, 1 to 5– Spatial smoothing: 4 types– Contrast enhancement: OFF, ON (can be set independ-
ently for 2D and THI)•Framerate: Max.391frames/s•CompoundingScan (ApliPure): Available with all convex and lin-
ear transducers•AutoSTC/GAIN adjustment (QuickScan): Available
Single diplay of a 4D image, Single display of a planar image of a 4D image, Dual display of a 4D image and a planar image, 4-frame display of a 4D image and three planar images, Multiframe display of planar images of a 4D image
•Autoadjustment: Baseshift,VelocityRange•RealtimeAutotrace: Available•Maximummeasurable velocity PW: 6.75 m/s (±3.37 m/s) HPRF: 6.75 m/s (±3.37 m/s) CW: 19.2 m/s (±9.65 m/s)•AutoVelocityRangeandZeroShift Control (iDoppler): Available
(USDF-590A is required)•FlashTrigger: Manual,Internal,ECG•MultipleFlash: 1–15•MonitorMode: Available•ApplicableTransducers:PSM-20CT,PSM-37CT,
PSM-30BT, PVM-375AT
DataManagementunit(UIDM-590Aisrequired)•Acquiringandsaving ultrasound images: Acquires dynamic and still imag-
es output from diagnostic ultra-sound systems used for routine examinations and/or detailed examinations in hospitals or examination rooms and saves such images.
7
MPDUS0017EA
•Acquisitionmethods: Acquisitionofimagesintotheultrasound workstation is per-formed using either of two tech-niques: one is Pre-Trigger/Post-Trigger acquisition, for standard real-time images; and the other is IM-Transfer acquisition, in which the images stored in image memory of the diagnostic ultrasound system are acquired one at a time in order to acquire images with a higher frame rate.
•Displayingandediting images: Displays on the monitor the
images acquired as described above and permits the user to display these images for four-frame display, playback in syn-chronization with the R wave of the ECG, etc.
•SupportofDICOM functions (UDDS-590A is required): Supports the following DICOM
•Stressecho (UDSE-590A is required): Provides the acquisition/display/
scoring functions which support stress echo examinations in the hospital or laboratory.
•Integratedoperability: Canbeoperatedfromthemainpanel of the diagnostic ultra-sound system and supports transmission/reception of data including patient IDs.
•PanoramicView (UDPA-590A is required): This function enables a continu-
ous image for a wide area to be displayed by moving the trans-ducer along the body surface.
•OutputtothePrinter– Output to the printer provided with the diagnostic ultra-
sound system– Output to the network printer in DICOM format– Output to local or network printers that are Windows
XP compatible•Report
– WMS (Wall Motion Scoring): Conforms to ASE.– Import and display of various measurement results– Display of data measured by the diagnostic ultrasound
– Maximum number of characters for user name: 64 alphanumeric characters– Maximum number of characters for password: 64 alphanumeric characters– Maximum number of users that can be registered: 64 users– Entry of user names and passwords is case-sensitive.
•Logoff•EmergencyLog-on
ImageExportviaUSB•MemoryDevice (Operation with all memory devices is not guaranteed.)
ReferencesignalkitThis function provides reference signal display and ECG trigger mode in single mode.This mode requires the reference signal kit UJUR-590A.•Signal: ECG(LeadII) AUX
PCG•ECGTrigger: 1channel•PCGFilter: 3stepsavailable•ECGsyncronization setting: 0 to 1.94 s
Imagememory•No.ofimagesthatcan be recorded
– 2D mode: Up to 512 images– CDI mode: Up to 512 images– M mode MCDI mode PWD/CWD mode: Up to 120 s
Measurement•Bmode: Distance(8ch),angle(8ch),
area (8 ch), circumference (8 ch), volume (1 ch), cross distance (8 ch), parallel distance (8 ch), hip joint (8 ch), meanIMT (8 ch), and curve distance (8 ch)
coNforMANcE StANDArDSEU and other regions requiring compliance with European Directive 93/42/EEC and subsequent amendments•General: EN60601-1(2006)•Particular: EN60601-2-37(2008)•Acousticpower: InformationforManufacturers
Seeking Marketing Clearance of Diagnostic Ultrasound Systems and Transducers (2008) (FDA guidance)
Seeking Marketing Clearance of Diagnostic Ultrasound Systems and Transducers (2008) (FDA guidance)
•EMC: IEC60601-1-2(2001),Amd.1(2004)
DiMENSioNS AND MASS•Externaldimensions: Colorsystems(includingcardio-
vascular color systems): 451 mm (W) × 785 mm (D) × 1,276 to 1,488 mm (H)
•Mass: Approximately83kg(peripheralunits and TEE stand not includ-ed)
oPErAtiNg coNDitioNS•Powersupplyrequirements
– Line voltage: 100 VAC to 127 VAC (50 Hz) 220 VAC to 240 VAC
– Line frequency: 50 Hz to 60 Hz– Power capacity: 1030 VA (max.)
•Environmentalconditions– Operating conditions
· Ambient temperature: 10°C to 35°C· Relativehumidity: 35%to85%(nocondensation)· Atmospheric pressure: 700 hPa to 1060 hPa
– Storage and transportation conditions· Ambient temperature: -10°C to 55°C· Relativehumidity: 30%to85%(nocondensation)· Atmospheric pressure: 700 hPa to 1060 hPa
•Safetyclassification– According to the type of protection against electric
shock: CLASS I EQUIPMENT
– According to the degree of protection against electric shock: EQUIPMENT WITH TYPE-BF APPLIED PARTS
– According to the degree of protection against harmful ingress of water: Ordinary EQUIPMENT (enclosed EQUIPMENT without protection against ingress or water)
– According to the degree of safety of application in the presence of a FLAMMABLE ANESTHETIC MIXTURE WITH AIR or WITH OXYGEN OR NITROUS OXIDE: EQUIPMENT not suitable for use in the presence of a FLAMMABLE ANESTHETIC MIXTURE WITH AIR or WITH OXYGEN OR NITROUS OXIDE
– According to the mode of operation: CONTINUOUS OPERATION
11
MPDUS0017EA
MASS
model name name of component mass [kg] (lb)
System main unit
SSA-590A Main unit 83 (183.0)
Options/Accessories for main unit
BD-X201M DVD 4.8 (10.6)
BD-X201ME DVD 4.8 (10.6)
CP30W Color printer 7.3 (16.1)
CP30DW Color printer 7.3 (16.1)
P93W B/W printer 2.8 (6.2)
P93DW B/W printer 2.8 (6.2)
P95DW B/W printer 2.6 (5.7)
UAEH-590A M-TEE hanger kit 1.6 (3.5)
UDDS-590A DICOM system kit 0.5 (1.1)
UDPA-590A Panoramic View kit 0.5 (1.1)
UDSE-590A Stress Echo kit 0.5 (1.1)
UICV-590A CV kit 1.4 (3.1)
UICW-590A CW kit 0.5 (1.1)
UIDM-590A Data management unit 1.4 (3.1)
UIMV-590A Mecha 4D kit 0.7 (1.5)
UIPS-590A Transducer selector 0.3 (0.7)
UIQS-590A B-PSP & CDI-PSP/QSP kit 0.1 (0.2)
UIUG-590A Premium kit 2.0 (4.4)
UJUR-590A Reference signal kit 0.9 (2.0)
UJUR-592A Reference signal kit 0.9 (2.0)
UP-25MD Color printer 5.7 (12.6)
UP-D23MD Color printer 6.5 (14.3)
UP-D25MD Color printer 5.5 (12.1)
UP-897 B/W printer 2.6 (5.7)
USAC-590A ACM kit 0.1 (0.2)
USDA-590A DCA kit 0.1 (0.2)
USDF-590A Dynamic Flow kit 0.1 (0.2)
USHI-590A CHI/FEI kit 0.1 (0.2)
USHP-590A HPRF kit 0.1 (0.2)
USTD-590A TDI kit 0.1 (0.2)
USTI-590A TIC kit 0.1 (0.2)
USTS-590A Trapezoid scan kit 0.1 (0.2)
UZCA-590A Cable for printer 0.5 (1.1)
UZFS-590A Footswitch kit 1.4 (3.1)
UZGW-590A Gel warmer 1 (2.2)
UZRI-590AMounting kit for peripheral unit (for a single unit)
1.2 (2.6)
UZRI-591AMounting kit for peripheral unit (for 2 units)