Top Banner
PP (polypropylene) Body Material for Clean Environment. EPDM for Seal Rubber. SUS304 for Metallic Materials. Chemical Industry Food Industry Medical Industry Medicine Industry Oil-Free. Visible Fluid by Transparent Body Color. Clean-room packaging Non- grease Copper alloy free material option Push-In Fitting Type Flow Control Valve for Clean Environment Needle Valve PP Series
15

Needle Valve PP Series - Microsoft · Controller Series Needle Valve PP Series (polypropylene) PJNMU B1 B2 øP T ød F1 F2 (g) CAD max. min. PJNMU4④⑥ 4 (5/32) 20.6 18.1 21.1 10

Aug 10, 2020

Download

Documents

dariahiddleston
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: Needle Valve PP Series - Microsoft · Controller Series Needle Valve PP Series (polypropylene) PJNMU B1 B2 øP T ød F1 F2 (g) CAD max. min. PJNMU4④⑥ 4 (5/32) 20.6 18.1 21.1 10

●PP (polypropylene) Body Material for Clean Environment.

●EPDM for Seal Rubber.

●SUS304 for Metallic Materials.

Chemical Industry Food IndustryMedical Industry Medicine Industry

●Oil-Free.

●Visible Fluid by Transparent Body Color.

Clean-roompackaging

Non-grease

Copper alloy free material

option

Push-In Fitting Type Flow Control Valve for Clean EnvironmentNeedle Valve PP Series

Page 2: Needle Valve PP Series - Microsoft · Controller Series Needle Valve PP Series (polypropylene) PJNMU B1 B2 øP T ød F1 F2 (g) CAD max. min. PJNMU4④⑥ 4 (5/32) 20.6 18.1 21.1 10

Controller SeriesNeedle Valve PP Series (polypropylene)

■ Model Designation (Example)

CPJN 6 01

② Tube dia.

③ Thread sizeThread size Metric thread (mm) Taper pipe thread

Code M5 01 02 03 04Size M5×0.8 R1/8 R1/4 R3/8 R1/2

Needle Valve PP Series①

Type

③Thread size

②Tube dia.

⑤Packaging option

⑥Thread sealing option

⑤ Packaging optionNo code:Standard packageC:Clean-room package

⑥ Thread sealing option (taper thread only)No code:Standard (No Sealock and seal tape)S:Sealock on threadTP:Seal tape on thread

Code Type Code Type

C Elbow Union Straight

① Type

④Seal rubber material

④ Seal rubber materialNo code:EPDMF:FKMN:NBR

※. Inch sizes are for PJSMU type only. Specify 4 for 5/32" and 8 for 5/16 "

4 (5/32) 68 (5/16) 10 121/4 3/8 1/2ø4 ø6ø8 ø10 ø12ø6.35 ø9.53 ø12.7

Code

mm size

MU

mm sizeinch size

Page 3: Needle Valve PP Series - Microsoft · Controller Series Needle Valve PP Series (polypropylene) PJNMU B1 B2 øP T ød F1 F2 (g) CAD max. min. PJNMU4④⑥ 4 (5/32) 20.6 18.1 21.1 10

■ Construction

Elastic sleeve (EPDM※1)

Tube

Release ring (PP)

Lock-claws (Stainless steel)

O-ring (EPDM※1)

Resin body (PP)

Metallic body (SUS304)

Guide ring (SUS304)

Locknut (SUS304)

Symbol

Tube End

Needle (SUS304)

■ SpecificationsFluid medium Air / Water / Other chemicals (※1)

Operating pressure range (at 0 ~20ºC) ※2

Max. vacuumOperating temp. range

※ 1. Make sure to follow the instructions below when the fluid medium is water orother chemicals.

1. Surge pressure must be controlled lower than max. operating pressure when using water or liquid as a fluid medium.

2. Be sure to place Insert Ring into the tube edge when using water or liquid as a fluid medium.

3. The specification above may not be applied, depending on the kind of chemicals, solvent, or mixed gases used as fluid medium. Contact us first.

※ 2. If operating temp. exceeds 68 (20℃) , refer to the following chart “Relation of Operating Temp. & Max. Operating Pressure”.

Warning

※1. EPDM / NBR for option

※2. Gasket for metric thread: SUS316+FKM

■ Relation of Operating Temp. & Max. Operating Pressure

0 20 40 60 80

0.10.20.30.40.50.60.70.80.91.0

Operating temp. (°C)

Max

. ope

ratin

g pr

essu

re (

MP

a)

32 ~ 176°F (0 ~ 80°C) (no freezing) (Seal rubber NBR: 32 ~ 140°F )-29.5in. Hg (-100kPa)

0 ~130psi(0 ~ 0.9 MPa)at 32 ~68°F

°F

Page 4: Needle Valve PP Series - Microsoft · Controller Series Needle Valve PP Series (polypropylene) PJNMU B1 B2 øP T ød F1 F2 (g) CAD max. min. PJNMU4④⑥ 4 (5/32) 20.6 18.1 21.1 10

Controller SeriesNeedle Valve PP Series (polypropylene)

■ How to identify the series of Throttle (Needle) Valve and Speed Controller

Detailed Safety InstructionsBefore using PISCO products, be sure to read “Safety Instructions” and “Safety Instruction Manual” and “Common Safety Instructions for Controllers”.

Warning1. When controlling the speed of actuators, slowly release the air by adjusting the needle

from a fully closed state. In case the needle is opened, actuator can move suddenly.Turn needle in the clockwise direction to close, and in the counterclockwise to open.

2. Do not swing or rotate resin body of the products by force. It may damage to theproducts and cause a fluid leakage.

3. Resin can be deteriorated by being exposed to direct sunlight or ultraviolet rays.

Caution1. Throttle (Needle) valve permits some air leakage. Do not use the products for the

application which requires no leakage.2. The seal rubber material EPDM is not suitable for general air piping, due to its inferior

durability against mineral oil.3. Taper thread is not coated by Sealock. When coating the thread with seal tape or

sealant, do not coat 1.5 to 2 screw ridges from the tip of the thread.4. If there is a possibility of fire by a fluid leakage, implement specific countermeasures such

as using a protective cover in order to protect machines / facilities from damages or fire.5. Tube insertion into Throttle (Needle) Valve PP Series is tighter than that of Throttle

(Needle) Valves due to its oil-free specification. Make sure to insert tube up to tubeend. When inserting a tube, put a liquid like water on the tube, which does not affect theproduct and the tube. It will improve the smoothness of tube insertion.

■ How to adjust the speed1. Speed adjustment of actuators

① Increasing speed Tu r n t h e n e e d l e i nthe counterc lockwised i rec t ion f rom a fu l lyclosed state. The morethe needle is opened, thefaster the actuator moves. Make sure to tighten thelocknut at the desiredspeed. The speed settingcan be changed withouttightening the locknut.

② Reducing speed

Turn the needle in the

c lockw ise d i rec t i on

w h e n t h e s p e e d i s

too fas t . Make sure

to tighten the locknut

at the desired speed.

The speed setting can

be changed wi thout

tightening the locknut.

Needle

Release-ring

Throttle (Needle) Valve Speed ControllerResin body

SeriesRelease-ring

color

Resin body

colorNeedle

Throttle (Needle) Valve Black BlackWith groove

Throttle (Needle) Valve Clean-room package Light-blue Light-gray

Throttle (Needle) Valve PP Series Semi-transparent Semi-transparent With groove

Speed Controller Black Black Without groove

Page 5: Needle Valve PP Series - Microsoft · Controller Series Needle Valve PP Series (polypropylene) PJNMU B1 B2 øP T ød F1 F2 (g) CAD max. min. PJNMU4④⑥ 4 (5/32) 20.6 18.1 21.1 10

■ How to insert and disconnect1. How to insert and disconnect tubes

① Tube insertion

Insert a tube into Push-In Fitting up to the tube end. Lock-claws bite the tube

and fix it automatically, then the elastic sleeve seals around the tube.

Refer to “2. Instructions for Tube Insertion” under “Common Safety Instructions

for Fittings” .

② Tube disconnection

The tube is disconnected by pushing release-ring to release Lock-claws.

Make sure to stop air supply before the tube disconnection.

2. How to tighten thread① Tightening thread

Use a spanner to tighten a hexagonal-column.

Refer to “Table: Recommended tightening torque” under “2. Instructions for

Installing Controllers” in “Common Safety Instructions for Controllers”.

Hexagonal-column

Page 6: Needle Valve PP Series - Microsoft · Controller Series Needle Valve PP Series (polypropylene) PJNMU B1 B2 øP T ød F1 F2 (g) CAD max. min. PJNMU4④⑥ 4 (5/32) 20.6 18.1 21.1 10

Controller SeriesNeedle Valve PP Series (polypropylene)

PJNMU

B1 B2 øP T ød F1 F2 (g)CAD

max. min.

PJNMU4④⑥ 4 (5/32) 20.6 18.1 21.1 10 10.5 15 3.2 12.7 4.8 7.9 PJNMU4_

PJNMU6④⑥ 6 25.3 21.5 24.6 12.5 13.1 17.1 3.2 14.8 6.2 13 PJNMU6_

PJNMU8④⑥ 8 (5/16) 28.4 24.6 28 14.8 15.4 18.1 3.2 18.2 7.2 23 PJNMU8_

PJNMU10④⑥ 10 32.9 28.9 32 18.2 19.7 20.4 4.2 22.2 8.7 41 PJNMU10_

PJNMU12④⑥ 12 35.4 31.5 37.1 21.2 22.7 23.6 4.2 25.7 10.2 58 PJNMU12_

PJNMU1/4④⑥ 1/4 25.3 21.5 24.6 12.5 13.1 17.1 3.2 14.8 6.2 13 PJNMU1_4_

PJNMU3/8④⑥ 3/8 32.9 28.9 32 18.2 19.7 20.4 4.2 22.2 8.7 42 PJNMU3_8_

PJNMU1/2④⑥ 1/2 35.4 31.5 37.4 21.2 22.7 23.9 4.2 25.7 10.2 57 PJNMU1_2_

2-B2

2-F2

F1

2-øP

2-øD

2-T

B1

2-ød

Unit:mm

compliant

■ In-Line Connection

Union Straight

※1. ④ in Model code / Replaced with “F” ( FKM), or “N” ( NBR) for Seal rubber material change.※2. ⑥ in Model code / Replaced with “C” for Clean-room package.

Model codeTube O.D.

øD

2-C

Tube endC

Weightfile name

Page 7: Needle Valve PP Series - Microsoft · Controller Series Needle Valve PP Series (polypropylene) PJNMU B1 B2 øP T ød F1 F2 (g) CAD max. min. PJNMU4④⑥ 4 (5/32) 20.6 18.1 21.1 10

Unit:mm

Model codeTube O.D.

øD R AB L1

L2 øP Tube endC

E1 E2Hex.

HWeight

(g)max. min. max. min.PJNC4-M5④⑤

4M5×0.8 2.9 29.7 27 26.8 24.1 7.2 9.9

1520 4.9 8 7

PJNC4-01④⑤⑥ R1/8 8 41 35.1 37 31.1 10.7 10 21.5 7.2 12 18

PJNC6-M5④⑤

6

M5×0.8 2.9 29.7 27 26.8 24.1 8.412.4 17.1

24.1 4.9 8 8

PJNC6-01④⑤⑥ R1/8 8 41 35.1 37 31.1 10.9 23.6 7.2 12 19

PJNC6-02④⑤⑥ R1/4 11.1 48.5 41.9 42.5 35.9 12.2 25.6 9.2 16 38

PJNC6-03④⑤⑥ R3/8 13.2 54.8 47.1 48.4 40.7 15.4 14.4 16.9 28.9 11 21 67

PJNC8-01④⑤⑥

8

R1/8 8 41 35.1 37 31.1 11.9

14.4 18.1

26.9 7.2 12 22

PJNC8-02④⑤⑥ R1/4 11.1 48.5 41.9 42.5 35.9 13.2 28.4 9.2 16 41

PJNC8-03④⑤⑥ R3/8 13.2 54.8 47.1 48.4 40.7 15.4 28.9 11 21 69

PJNC8-04④⑤⑥ R1/2 16 59.6 52.5 51.4 44.4 18 31 14 27 103

PJNC10-02④⑤⑥10

R1/4 11.1 48.5 41.9 42.5 35.9 14.817.6 20.4

31.1 9.2 16 44

PJNC10-03④⑤⑥ R3/8 13.2 54.8 47.1 48.4 40.7 16.7 31.4 11 21 71

PJNC10-04④⑤⑥ R1/2 16 59.6 52.5 51.4 44.4 18 33.8 14 27 106

PJNC12-03④⑤⑥12

R3/8 13.2 54.8 47.1 48.4 40.7 18.421 23.6

37.1 11 21 74

PJNC12-04④⑤⑥ R1/2 16 59.6 52.5 51.4 44.4 19.7 36.6 14 27 109

※1. “L1” and “L2” are reference values for height dimensions after tightening taper thread.

※2. ④ in Model code / Replaced with “F” (FKM), or “N” (NBR) for Seal rubber material change

※3. ⑤ in Model code / Replaced with “C” for Clean-room package

※4. ⑥ in Model code / Replaced with “S” for Sealock, or “TP” for Seal tape on thread.

R R

øD

øP

AL2

L1B

E1E2

CH

Metric thread type

BA

L

PJNC Elbow

compliant

Page 8: Needle Valve PP Series - Microsoft · Controller Series Needle Valve PP Series (polypropylene) PJNMU B1 B2 øP T ød F1 F2 (g) CAD max. min. PJNMU4④⑥ 4 (5/32) 20.6 18.1 21.1 10

Controller SeriesNeedle Valve PP Series (polypropylene)

■ Flow characteristic (Fluid: Air)

Elbow type

0

20406080100120140

1 2 3 4 5 6 7 8

0.7

0.9

0.5

0.3

0.1

Needle rotations (times)

Flo

w r

ate

(l/m

in(A

NR

))

Control flow

Pre

ssur

e (M

Pa)

PJNC 4-M56-M5

0

100

200

300

400

1 2 3 4 5 6 7 8 9 10 11

0.7

0.9

0.50.30.1

Needle rotations (times)

Flo

w r

ate

(l/m

in(A

NR

))

Control flow

Pre

ssur

e (M

Pa)

PJNC 4-016-018-01

0

500400300200100

600700

0.3

0.1

1 2 3 4 5 6 7 8 9 10 11 12 13

0.7

0.9

0.5

Needle rotations (times)

Flo

w r

ate

(l/m

in(A

NR

))

Control flow

Pre

ssur

e (M

Pa)

PJNC 6-028-0210-02

0

200400600800

140012001000

0.3

0.1

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15

0.3

0.1

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15

0.7

0.9

0.5

Needle rotations (times)

Flo

w r

ate

(l/m

in(A

NR

))

Control flow

Pre

ssur

e (M

Pa)

PJNC 6-038-0310-0312-03

0

400800

2800

1200160020002400

0.7

0.9

0.5

Needle rotations (times)

Flo

w r

ate

(l/m

in(A

NR

))

Control flow

Pre

ssur

e (M

Pa)

PJNC 8-0410-0412-04

0

50

0

100

150

200

1 2 3 4 5 6 7 8 9 10

0.7

0.9

0.5

0.3

0.1

PJNMU 4 (PJNMU 5/32)

0

100

0

200

300

400

500

0.3

0.1

1 2 3 4 5 6 7 8 9 10 11

0.70.9

0.5

PJNMU 6

0

1000

200

800

500

300

600

400

700

1 2 3 4 5 6 87

0.7

0.9

0.50.30.1

PJNMU 8

0

2000

400600800

1000120014001600

1 2 3 4 5 6 7 8

0.7

0.9

0.5

0.30.1

PJNMU 10

0

500

0

1000

1500

2000

2500

1 2 3 4 5 6 7 8

0.7

0.9

0.5

0.3

0.1

PJNMU 12

PJNMU 1/4

(PJNMU 5/16) PJNMU 3/8

PJNMU 1/2

Union Straight Type

Control flow

Flo

w r

ate

(l/m

in(A

NR

))

Control flow

Control flow

Flo

w r

ate

(l/m

in(A

NR

))F

low

rat

e (l/

min

(AN

R))

Needle rotations (times)

Needle rotations (times)

Needle rotations (times)

Needle rotations (times)

Needle rotations (times)

Control flow

Flo

w r

ate

(l/m

in(A

NR

))

Control flow

Flo

w r

ate

(l/m

in(A

NR

))

Pre

ssur

e (M

Pa)

Pre

ssur

e (M

Pa)

Pre

ssur

e (M

Pa)

Pre

ssur

e (M

Pa)

Pre

ssur

e (M

Pa)

Page 9: Needle Valve PP Series - Microsoft · Controller Series Needle Valve PP Series (polypropylene) PJNMU B1 B2 øP T ød F1 F2 (g) CAD max. min. PJNMU4④⑥ 4 (5/32) 20.6 18.1 21.1 10

Safety Instructions

SAFETY Instructions

Warning

 This safety instructions aim to prevent personal injury and damage to properties by requiring proper use of PISCO products. Be certain to follow ISO 4414 and JIS B 8370

ISO 4414:Pneumatic fluid power…Recomendations for the application of equipment to transmission and control systems.

JIS B 8370:General rules and safety requirements for systems and their components.This safety instructions is classified into “Danger”, “Warning” and “Caution” depending on the degree of danger or damages caused by improper use of PISCO products.

1. Selection of pneumatic products① A user who is a pneumatic system designer or has sufficient experience

and technical expertise should select PISCO products.② Due to wide variety of operating conditions and applications for PISCO

products, carry out the analysis and evaluation on PISCO products.The pneumatic system designer is solely responsible for assuring thatthe user's requirements are met and that the application presents nohealth or safety hazards. All designers are required to fully understandthe specifications of PISCO products and constitute all systems basedon the latest catalog or information, considering any malfunctions.

2. Handle the pneumatic equipment with enough knowledge and experience① Improper use of compressed air is dangerous. Assembly, operation

and maintenance of machines using pneumatic equipment should beconducted by a person with enough knowledge and experience.

3. Do not operate machine / equipment or remove pneumatic equipment untilsafety is confirmed.① Make sure that preventive measures against falling work-pieces or

sudden movements of machine are completed before inspection ormaintenance of these machine.

② Make sure the above preventive measures are completed. Acompressed air supply and the power supply to the machine must beoff, and also the compressed air in the systems must be exhausted.

③ Restart the machines with care after ensuring to take all preventivemeasures against sudden movements.

Danger Hazardous conditions. It can cause death or seriouspersonal injury.

Warning Hazardous conditions depending on usages. Improper use ofPISCO products can cause death or serious personal injury.

Caution Hazardous conditions depending on usages. Improper use of PISCOproducts can cause personal injury or damages to properties.

※ . This safety instructions are subject to change without notice.

Page 10: Needle Valve PP Series - Microsoft · Controller Series Needle Valve PP Series (polypropylene) PJNMU B1 B2 øP T ød F1 F2 (g) CAD max. min. PJNMU4④⑥ 4 (5/32) 20.6 18.1 21.1 10

Disclaimer1. PISCO does not take any responsibility for any incidental or indirect

loss, such as production line stop, interruption of business, lossof benefits, personal injury, etc., caused by any failure on use orapplication of PISCO products.

2. PISCO does not take any responsibility for any loss caused by naturaldisasters, fires not related to PISCO products, acts by third parties, andintentional or accidental damages of PISCO products due to incorrectusage.

3. PISCO does not take any responsibility for any loss caused by improperusage of PISCO products such as exceeding the specification limit or notfollowing the usage the published instructions and catalog allow.

4. PISCO does not take any responsibility for any loss caused by remodelingof PISCO products, or by combinational use with non-PISCO products andother software systems.

5. The damages caused by the defect of Pisco products shall be covered butlimited to the full amount of the PISCO products paid by the customer.

Page 11: Needle Valve PP Series - Microsoft · Controller Series Needle Valve PP Series (polypropylene) PJNMU B1 B2 øP T ød F1 F2 (g) CAD max. min. PJNMU4④⑥ 4 (5/32) 20.6 18.1 21.1 10

Safety Instructions

SAFETY INSTRUCTION MANUAL

Danger1. Do not use PISCO products for the following applications.

① Equipment used for maintaining / handling human life and body.② Equipment used for moving / transporting human.③ Equipment specifically used for safety purposes.

Warning1. Do not use PISCO products under the following conditions.

① Beyond the specifications or conditions stated in the catalog, or the instructions.② Under the direct sunlight or outdoors.③ Excessive vibrations and impacts.④ Exposure / adhere to corrosive gas, inflammable gas, chemicals, seawater, water and vapor. *

* Some products can be used under the condition above(④), refer tothe details of specification and condition of each product.

2. Do not disassemble or modify PISCO products, which affect theperformance, function, and basic structure of the product.

3. Turn off the power supply, stop the air supply to PISCO products, and make surethere is no residual air pressure in the pipes before maintenance and inspection.

4. Do not touch the release-ring of push-in fitting when there is a working pressure.The lock may be released by the physical contact, and tube may fly out or slip out.

5. Frequent switchover of compressed air may generate heat, and there is arisk of causing burn injury.

6. Avoid any load on PISCO products, such as a tensile strength, twistingand bending. Otherwise, there is a risk of causing damage to the products.

7. As for applications where threads or tubes swing / rotate, use RotaryJoints, High Rotary Joints or Multi-Circuit Rotary Block only. The otherPISCO products can be damaged in these applications.

8. Use only Die Temperature Control Fitting Series, Tube Fitting Stainless SUS316Series, Tube Fitting Stainless SUS316 Compression Fitting Series or Tube FittingBrass Series under the condition of over 60℃ (140°F) water or thermal oil. OtherPISCO products can be damaged by heat and hydrolysis under the condition above.

9. As for the condition required to dissipate static electricity or provide an antistaticperformance, use EG series fitting and antistatic products only, and do not use other PISCOproducts. There is a risk that static electricity can cause system defects or failures.

10. Use only Fittings with a characteristic of spatter-proof such as Anti-spatter or Brass series in a place where flame and weld spatter isproduced. There is a risk of causing fire by sparks.

11. Turn off the power supply to PISCO products, and make sure there isno residual air pressure in the pipes and equipment before maintenance.Follow the instructions below in order to ensure safety.① Make sure the safety of all systems related to PISCO products before maintenance.② Restart of operation after maintenance shall be proceeded with care after

ensuring safety of the system by preventive measures against unexpectedmovements of machines and devices where pneumatic equipment is used.

③ Keep enough space for maintenance when designing a circuit.12. Take safety measures such as providing a protection cover if there is a

risk of causing damages or fires on machine / facilities by a fluid leakage.

PISCO products are designed and manufactured for use in general industrial machines. Be sure to read and follow the instructions below.

Page 12: Needle Valve PP Series - Microsoft · Controller Series Needle Valve PP Series (polypropylene) PJNMU B1 B2 øP T ød F1 F2 (g) CAD max. min. PJNMU4④⑥ 4 (5/32) 20.6 18.1 21.1 10

Caution1. Remove dusts or drain before piping. They may get into the peripheral

machine / facilities and cause malfunction.2. When inserting an ultra-soft tube into push-in fitting, make sure to place

an Insert Ring into the tube edge. There is a risk of causing the escape oftube and a fluid leakage without using an Insert Ring.

3. The product incorporating NBR as seal rubber material has a risk ofmalfunction caused by ozone crack. Ozone exists in high concentrationsin static elimination air, clean-room, and near the high-voltage motors,etc. As a countermeasure, material change from NBR to HNBR or FKM isnecessary. Consult with PISCO for more information.

4. Special option “Oil-free” products may cause a very small amount of a fluidleakage. When a fluid medium is liquid or the products are required to beused in harsh environments, contact us for further information.

5. In case of using non-PISCO brand tubes, make sure the tolerance of theouter tube diameter is within the limits of Table 1.●Table 1. Tube O.D. Tolerance

mm size Nylon tube Polyurethane tube inch size Nylon tube Polyurethane tubeø1.8mm ─ ±0.05mm ø1/8 ±0.1mm ±0.15mmø3mm ─ ±0.15mm ø5/32 ±0.1mm ±0.15mmø4mm ±0.1mm ±0.15mm ø3/16 ±0.1mm ±0.15mmø6mm ±0.1mm ±0.15mm ø1/4 ±0.1mm ±0.15mmø8mm ±0.1mm ±0.15mm ø5/16 ±0.1mm ±0.15mmø10mm ±0.1mm ±0.15mm ø3/8 ±0.1mm ±0.15mmø12mm ±0.1mm ±0.15mm ø1/2 ±0.1mm ±0.15mmø16mm ±0.1mm ±0.15mm ø5/8 ±0.1mm ±0.15mm

6. Instructions for Tube Insertion① Make sure that the cut end surface of the tube is at right angle without

a scratch on the surface and deformations.② When inserting a tube, the tube needs to be inserted fully into the push-

in fitting until the tubing edge touches the tube end of the fitting asshown in the figure below. Otherwise, there is a risk of leakage.

Tube end

Sealing

Tube is not fully inserted up to tube end.

③ After inserting the tube, make sure it is inserted properly and not to bedisconnected by pulling it moderately.

※. When inserting tubes, Lock-claws may be hardly visible in the hole, observedfrom the front face of the release-ring. But it does not mean the tube willsurely escape. Major causes of the tube escape are the followings;①Shear drop of the lock-claws edge②The problem of tube diameter (usually small)Therefore, follow the above instructions from ① to ③, even lock-clawsis hardly visible.

Good Imcomplete

Page 13: Needle Valve PP Series - Microsoft · Controller Series Needle Valve PP Series (polypropylene) PJNMU B1 B2 øP T ød F1 F2 (g) CAD max. min. PJNMU4④⑥ 4 (5/32) 20.6 18.1 21.1 10

7. Instructions for Tube Disconnection① Make sure there is no air pressure inside of the tube, before disconnecting it.② Push the release-ring of the push-in fitting evenly and deeply enough to

pull out the tube toward oneself. By insufficient pushing of the release-ring, the tube may not be pulled out or damaged by scratch, and tubeshavings may remain inside of the fitting, which may cause the leakagelater.

8. Instructions for Installing a fitting① When installing a fitting, use proper tools to tighten a hexagonal-column

or an inner hexagonal socket. When inserting a hex key into the innerhexagonal socket of the fitting, be careful so that the tool does nottouch lock-claws. The deformation of lock-claws may result in a poorperformance of systems or an escape of the tube.

② Refer to Table 2 which shows the recommended tightening torque. Donot exceed these limits to tighten a thread. Excessive tightening maybreak the thread part or deform the gasket and cause a fluid leakage.Tightening thread with tightening torque lower than these limits maycause a loosened thread or a fluid leakage.

③ Adjust the tube direction while tightening thread within these limits,since some PISCO products are not rotatable after the installation.

●Table 2: Recommended tightening torque / Sealock color / GasketmaterialsThread type Thread size Tightening torque Sealock color Gasket materials

Metric thread

M3×0.5 0.7N·m

SUS304NBR

M5×0.8 1.0 ~ 1.5N·mM6×1 2 ~ 2.7N·m

M3×0.5 0.5 ~ 0.6N·m

POMM5×0.8 1 ~ 1.5N·mM6×0.75 0.8 ~ 1N·mM8×0.75 1 ~ 2N·m

Taper pipe thread

R1/8 7 ~ 9N·m

White ─R1/4 12 ~ 14N·mR3/8 22 ~ 24N·mR1/2 28 ~ 30N·m

Unified thread No.10-32UNF 1.0 ~ 1.5N·m ─ SUS304、NBR

National pipe thread taper

1/16-27NPT 7 ~ 9N·m

White ─1/8-27NPT 7 ~ 9N·m1/4-18NPT 12 ~ 14N·m3/8-18NPT 22 ~ 24N·m1/2-14NPT 28 ~ 30N·m

※ These values may differ for some products. Refer to each specification as well.9. Instructions for removing a fitting

① When removing a fitting, use proper tools to loosen a hexagonal-columnor an inner hex bolt.

② Remove the sealant stuck on the mating equipment. The remainedsealant may get into the peripheral equipment and cause malfunctions.

10. Arrange piping avoiding any load on fittings and tubes such as twist,tensile, moment load, shaking and physical impact. These may causedamages to fittings, tube deformations, bursting and the escape of tubes.

Safety Instructions

Page 14: Needle Valve PP Series - Microsoft · Controller Series Needle Valve PP Series (polypropylene) PJNMU B1 B2 øP T ød F1 F2 (g) CAD max. min. PJNMU4④⑥ 4 (5/32) 20.6 18.1 21.1 10

Controller Series

Common Safety Instructions for Controllers

Warning

Before selecting or using PISCO products, read the following instructions. Read the detailed instructions for individual series as well as the instructions below.

1. Some products have an air direction to control. Make sure to distinguish thedirection by marking on the products. Installing the product with the wrongdirection may cause personal injury or property damage.

2. Avoid any load on PISCO products such as a tensile strength, twisting,bending, dropping and excessive impacts. These may cause damage to theproducts.

3. Locknut needs to be tightened by hand. Do not use any tool. Using tools totighten the locknut may cause damage to the products. Also, inadequatetightening may loosen the locknut and the initial setting can be changed.

4. Use clean air to supply. Dusts and sludge may result in the change of theinitial setting.

Page 15: Needle Valve PP Series - Microsoft · Controller Series Needle Valve PP Series (polypropylene) PJNMU B1 B2 øP T ød F1 F2 (g) CAD max. min. PJNMU4④⑥ 4 (5/32) 20.6 18.1 21.1 10

Caution1. Refer to “Common Safety Instructions for Fittings” for the safety instructions

for fitting part.

2. Instructions for Installing Controllers① Use proper tools to tighten a hexagonal-column or a knurling, when installing

the controller.

② Refer to the following table which shows the recommended tightening torqueto tighten thread. Excessive tightening may break the thread part or deformthe gasket to cause a fluid leakage. Tightening thread with the tighteningtorque lower than these limits may cause a loosened thread or a fluid leakage.

● Table: Recommended tightening torque (hexagonal-column) (knurling)

Thread type Thread size Tightening torque Thread type Thread size Tightening torque

Metric thread M3×0.5 0.7N・m

Metric thread M5×0.8 1/6 turns

after hand tightening

M5×0.8 1~1.5N・m M6×1M6×1 2~2.7N・m M10×1

Taper pipe thread

R1/8 7~9N・m Parallel pipe thread

G3/8 1/2~1 turns after hand tighteningR1/4 12~14N・m G1/2

R3/8 22~24N・mR1/2 28~30N・m

Unified thread No.10-32UNF 1.5~1.9N・m

National pipe thread taper

1/16-28NPT 7~9N・m1/8-27NPT 7~9N・m1/4-18NPT 12~14N・m3/8-18NPT 22~24N・m1/2-14NPT 28~30N・m

Parallel pipe thread

G3/8 After hand tightening1/2~1 turnsG1/2

3. Instructions for removing Controller① When removing controllers, use proper tools to loosen a hexagonal-column or

a knurling.② Remove the sealant stuck on the mating equipment. The remained sealant

may get into the peripheral equipment and cause malfunctions.

4. Fixed Orifice Joint Series and Speed Controller Constant Flow Series havedeviation of flow rate. Contact us, in case a very accurate amount of flow rateis required.

5. If PISCO products generate heat by an adiabatic compression, totaltemperature including the heat from the product must be controlled within therange of the specification.