NEC RSenCounter 4000 Reference Manual Part No. 2350REF01 August 2001
198
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: NEC4000 Programming

NECRSenCounter 4000

Reference Manual

Part No. 2350REF01August 2001

Page 2: NEC4000 Programming

This manual has been developed by NEC Infrontia, Inc. It is intended for the use of its customers and service personnel, and should be read in its entirety before attempting to install or program the system. Any comments or suggestions for improving this manual would be appreciated. Forward your remarks to:

NEC Infrontia, Inc.4 Forest Parkway, Shelton, CT 06484

Attention: Manager, Technical [email protected]

Nothing contained in this manual shall be deemed to be, and this manual does not constitute, a warranty of, or representation with respect to, any of the Equipment covered. This manual is subject to change without notice and NEC Infrontia, Inc. has no obligation to provide any updates or corrections to this manual. Further, NEC Infrontia, Inc. also reserves the right, without prior notice, to make changes in equipment design or components as it deems appropriate. No representation is made that this manual is complete or accurate in all respects and NEC Infrontia, Inc. shall not be liable for any errors or omissions. In no event shall NEC Infrontia, Inc. be liable for any incidental or consequential damages in connection with the use of this manual. This document contains proprietary information that is protected by copyright. All rights are reserved. No part of this document may be photocopied or reproduced without prior written consent of NEC Infrontia, Inc.

© 2001 by NEC Infrontia, Inc. All Rights ReservedPrinted in U.S.A.

Page 3: NEC4000 Programming

Table of Contents

2350REF01

Table of Contents- 1

S-Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1

S-Mode Menu Structure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1

S-MODE MENU STRUCTURE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1

STATION NUMBER ASSIGNMENT [S1] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1SYSTEM CONFIGURATION [S2] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1

SYSTEM WIDE FEATURES [S2-1] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1STATION GROUP [S2-2] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3

STATION 1 [S2-2-1] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3STATION REGISTRATION [S2-3] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4

STATION 1 [S2-3-1] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4MASTER AND BACK UP ASSIGNMENT [S2-4] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5

EDIT MEMORY ALLOCATION TABLE [S3] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6

COMMON CONFIGURATION [S3-1] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6SYSTEM MASTER [S3-2] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9TRACKING MASTER [S3-3] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9LOCAL STATION [S3-4] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10

KEY ASSIGNMENT [S4] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11

KEY BOARD LEVEL 1 SELECTED [S4-1] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11KEYBOARD LEVEL PROGRAMMING [S4-1-1] . . . . . . . . . . . . . . . . . . . . . . . . . . .12

DOWNLOAD PROGRAMS [S5] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13

SYSTEM SOFTWARE [S5-1] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13SYSTEM SOFTWARE-BY STATION GROUP [S5-1-2] . . . . . . . . . . . . . . . . . . . . .14SYSTEM SOFTWARE-BY RANGE [S5-1-3] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .14INSTALLATION PROCEDURE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .14RUN THE SYSTEM TEST SOFTWARE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .14

INITIALIZATION [S6] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .15

CLEAR RAM AND INSTALL DEFAULT PROGRAM [S6-1] . . . . . . . . . . . . . . . . . . . . . .15CLEAR TOTAL AND COUNTERS [S6-2] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .15[S6-3] to [S6-9] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .15INSTALL DEFAULT MESSAGES [S6-10] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .15

ALL MESSAGES [S6-10-1] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .16SCREEN SYSTEM DESCRIPTOR [S6-10-2] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .16RECEIPT/CHECK SYSTEM DESCRIPTOR [S6-10-5] . . . . . . . . . . . . . . . . . . . . . . .16RECEIPT/CHECK HEADER AND FOOTER [S6-10-6] . . . . . . . . . . . . . . . . . . . . . .16CREDIT CARD AGREEMENT MESSAGE (CHARGE) [S6-10-7] . . . . . . . . . . . . .16CREDIT CARD AGREEMENT MESSAGE (CREDIT) [S6-10-8] . . . . . . . . . . . . . .16GUEST CHECK TRAIL MESSAGE [S6-10-9] . . . . . . . . . . . . . . . . . . . . . . . . . . . . .16KITCHEN PRINTER MESSAGE [S6-10-10] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .16 REPORT MESSAGE [S6-10-11] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .16

INSTALL DEFAULT FUNCTION KEYS [S6-11] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .16INSTALL DEFAULT KEYBOARD [S6-12] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .16

SYSTEM PASSWORD [S7] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .17SYSTEM TEST [S8] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .17

Page 4: NEC4000 Programming

Table of Contents

Table of Contents - 2

2350REF01

P-MODE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19

P-MODE MENU STRUCTURE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .19

P-MODE MENU STRUCTURE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .19

EDIT SYSTEM CONFIGURATION [P1] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .19

SYSTEM WIDE FEATURES [P1-1] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .19STATION GROUP [P1-2] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .21

STATION 1 [P1-2-1] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .21STATION REGISTRATION [P1-3] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .21

STATION 1 [P1-3-1] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .22MASTER AND BACK UP ASSIGNMENT [P1-4] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .23DOWNLOAD SYSTEM CONFIGURATION [P1-5] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .23

REPORT GROUPS AND TIME PERIODS [P2] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .24

MAJOR GROUP [P2-1] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .24MAJOR GROUP RECORD [P2-1-1] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .24

SUB GROUP [P2-2] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .25SUB GROUP [P2-2-1] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .25

PRODUCT MIX GROUP [P2-3] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .26PRODUCT MIX GROUP [P2-3-1] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .26

TIME PERIODS AUTO CONFIGURATION [P2-4] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .27TIME PERIOD BY MANUAL CONFIGURATION [P2-5] . . . . . . . . . . . . . . . . . . . . . . . . .27

TAXES [P3] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .28

TAX CONFIGURATION [P3-1] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .28TAX 1 [P3-1-1] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .28

TAX TABLE PROGRAMMING [P3-2] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .29TAX TABLE PROGRAMMING [P3-2-1] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .29

TAX OPTION [P3-3] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .30

SYSTEM OPTION [P4] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .31

GLOBAL OPTION [P4-1] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .31TRANSACTION OPTION [P4-2] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .33TABLE SERVICE OPTION [P4-3] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .34DRAWER AND TENDER OPTION [P4-4] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .35PRINT FORMAT AND OPTION [P4-5] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .36

RECEIPT OPTION [P4-5-1] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .36RECEIPT FORMAT [P4-5-2] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .36KITCHEN REQUISITION [P4-5-3] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .37REPORT [P4-5-4] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .39TRANSACTION LOG [P4-5-5] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .40SYSTEM LOG [P4-5-6] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .41KEY STROKE HISTORY [P4-5-7] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .42CTS (CLOSED TRANSACTION SUMMARY) [P4-5-8] . . . . . . . . . . . . . . . . . . . . . .42

CLOSING OPTION [P4-6] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .43DISPLAY OPTION [P4-7] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .44SCREEN CONFIGURATION [P4-8] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .44

ORDER/CHECK INFORMATION LINE (Line 1) [P4-8-1] . . . . . . . . . . . . . . . . . . .44ITEM LINE (Line 2-17) [P4-8-2] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .45ACTION LINE (Line 19) [P4-8-3] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .45SERVICE INFORMATION LINE [P4-8-4] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .46STATUS LINE [P4-8-5] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .46TENDER INFORMATION (Line 17) [P4-8-6] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .46

Page 5: NEC4000 Programming

Table of Contents

2350REF01

Table of Contents- 3

PLU PROGRAMMING [P5] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .47

PLU [P5-1] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .47CREATE OR EDIT PLU [P5-1-1] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .47CREATE PLU BY RANGE [P5-1-2] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .50DELETE PLU [P5-1-3] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .50DELETE PLU BY RANGE [P5-1-4] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .52PLU ACCESS FROM KEYBOARD [P5-1-5] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .52PLU ACCESS FROM PLU LIST [P5-1-6] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .53EDIT OPTIONAL PLU RECEIPT DESCRIPTOR [P5-1-7] . . . . . . . . . . . . . . . . . . . .54EDIT KP/KVS DESCRIPTOR [P5-1-8] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .54EDIT KP/KVS DESCRIPTOR [P5-1-8-1] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .55MENU KEY RELOCATION [P5-1-9] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .55

PLU PROPERTY [P-5-2] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .58PLU [P5-2-1] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .58

PLU SHIFT [P5-3] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .60PLU SHIFT [P5-3-1] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .61

PLU PRICE EDIT [P5-4] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .61PRICE EDIT [P5-4-1] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .62

PLU PRICE TABLE [P5-5] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .62PRICE TABLE [P5-5-1] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .63

PLU PRICE LEVEL SCHEDULER [P5-6] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .63CONDIMENT TABLE [P5-7] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .64

CONDIMENT TABLE [P5-7-1] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .64CONDIMENT CHAIN [P5-8] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .66

CONDIMENT CHAIN [P5-8-2] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .66LINKED PLU TABLE [P5-9] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .67

LINKED PLU TABLE (LPT) [P5-9-2] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .67DISCOUNT CATEGORY [P5-10] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .68

DISCOUNT CATEGORY [P5-10-1] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .68PRINT PLU BY TBL, PRICE LIST, PRICE SCHEDULER [P5-11] . . . . . . . . . . . . . . . . . .69DOWNLOAD [P5-13] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .72

INVENTORY [P6] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .73

SPECIAL ITEM STOCK [P6-1-2] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .73

MESSAGES [P7] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .74

FIXED SCREEN MESSAGE ON ACTION LINE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .74SCREEN MESSAGE [P7-2] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .74

SCREEN MESSAGE (SHORT) [P7-2-1] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .74SCREEN MESSAGE (LONG) [P7-2-2] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .80DEFAULT SYSTEM COLOR [P7-2-4] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .89

RECEIPT/GUEST CHECK MESSAGE [P7-3] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .89RECEIPT/GUEST CHECK HEADER AND FOOTER [P7-3-1] . . . . . . . . . . . . . . . .90RECEIPT/GUEST CHECK SYSTEM MESSAGE [P7-3-2] . . . . . . . . . . . . . . . . . . . .90CREDIT CARD AGREEMENT MESSAGE (CHARGE) [P7-3-3] . . . . . . . . . . . . . .95CREDIT CARD AGREEMENT MESSAGE (CREDIT) [P7-3-4] . . . . . . . . . . . . . . .95GUEST CHECK TRAIL MESSAGE [P7-3-5] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .96

KITCHEN PRINTER MESSAGE [P7-4] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .97KITCHEN PRINTER MESSAGE [P7-4-1] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .97KP GROUP DESCRIPTOR [P7-4-2] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .98

REPORT MESSAGE [P7-5] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .99REPORT MESSAGE [P7-5-1] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .99

Page 6: NEC4000 Programming

Table of Contents

Table of Contents - 4

2350REF01

MONTH AND DAY MESSAGE [P7-6] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .107MONTH AND DAY MESSAGE [P7-6-1] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .107

KEYBOARD SYSTEM [P8] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .110

EDIT FUNCTION KEY FROM KEYBOARD [P8-1] . . . . . . . . . . . . . . . . . . . . . . . . . . . . .110EDIT FUNCTION KEY FROM KEYBOARD [P8-1-1] . . . . . . . . . . . . . . . . . . . . . .110

EDIT FUNCTION KEY FROM A LIST [P8-2] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .111EDIT FUNCTION KEY FROM A LIST [P8-2-1] . . . . . . . . . . . . . . . . . . . . . . . . . . .111

EDIT MACRO KEY [P8-3] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .111MACRO KEY EDIT [P8-3-2] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .112

TIME ACTIVATE KEY [P8-4] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .113TIME ACTIVATE KEY [P8-4-1] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .114

TLU KEY PROGRAMMING [P8-5] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .114TLU KEY PROGRAMMING [P8-5-1] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .115

MLU KEY PROGRAMMING [P8-6] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .115MLU KEY PROGRAMMING [P8-6-1] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .116

COUPON AND AUTO-COMBO [P9] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .117

COUPON AND AUTO-COMBO OPTION [P9-1] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .117COUPON [P9-2] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .118

COUPON [P9-2-1] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .118AUTO COMBO PROGRAMMING [P9-3] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .122

AUTO COMBO PROGRAMMING [P9-3-1] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .122

HUMAN RESOURCES [P10] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .124

EMPLOYEE FILE [P10-1] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .124EMPLOYEE FILE [P10-1-1/999] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .125

TIME & ATTENDANCE [P10-2] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .126GLOBAL OPTIONS [P10-2-1] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .126HOLIDAY PAY PROGRAMMING [P10-2-2] . . . . . . . . . . . . . . . . . . . . . . . . . . . .127

JOB CODE TABLE [P10-3] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .128JOB CODE TABLE [P10-3-1] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .129

PAY RATE TABLE [P10-4] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .129PAY RATE TABLE [P10-4-1/60] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .130

AUTHORITY LEVEL [P10-5] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .130PRINT EMPLOYEE LIST [P10-6] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .137

PERIPHERALS [P11] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .137

CREATE/EDIT PRINTER LIST (1-30) [P11-1] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .137CREATE/EDIT PRINTER LIST [P11-1-1] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .137

RECEIPT/REPORT/LOG PRINTER ASSIGNMENT [P11-2] . . . . . . . . . . . . . . . . . . . . . .137RECEIPT/REPORT/LOG PRINTER ASSIGNMENT [P11-2-1] . . . . . . . . . . . . . . .138

CREATE/EDIT KITCHEN PRINTER TABLE [P11-3] . . . . . . . . . . . . . . . . . . . . . . . . . . .139KP TABLE [P11-3-1] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .140

KP TABLE ASSIGNMENT TO KP LEVEL [P11-4] . . . . . . . . . . . . . . . . . . . . . . . . . . . . .141KP TABLE ASSIGNMENT TO KP LEVEL [P11-4-1] . . . . . . . . . . . . . . . . . . . . . .142

KVS PROGRAMMING [P11-5] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .142SCALE [P11-6] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .143

SCALE [P11-6-1] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .143TARE WEIGHT TABLE [P11-6-2] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .144

CREDIT CARD INTERFACE [P11-7] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .144CREDIT CARD INTERFACE (P11-7-1] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .145CREDIT CARD MODEM LIST [P11-7-2] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .145CREDIT CARD MODEM ASSIGNMENT [P11-7-3] . . . . . . . . . . . . . . . . . . . . . . .146

Page 7: NEC4000 Programming

Table of Contents

2350REF01

Table of Contents- 5

CREDIT CARD TYPE CONFIGURATION [P11-7-4] . . . . . . . . . . . . . . . . . . . . . . .146TERMINAL MODE [P11-7-5] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .147

SCANNER [P11-8] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .148SCANNER INTERFACE [P11-8-1] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .148EAN13 INF. EMBEDDED BAR CODE [P11-8-2] . . . . . . . . . . . . . . . . . . . . . . . . . .149

OTHER PERIPHERAL CONFIGURATIONS [P11-15] . . . . . . . . . . . . . . . . . . . . . . . . . . .149POLLING MODEM CONNECTION [P11-15-1] . . . . . . . . . . . . . . . . . . . . . . . . . . .149USER CARD DEFINITION [P11-15-2] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .150EMPLOYEE CARD CONFIGURATION [P11-15-3] . . . . . . . . . . . . . . . . . . . . . . . .150DOWNLOAD LOGO TO TM-T88 [P11-15-6] . . . . . . . . . . . . . . . . . . . . . . . . . . . . .151POLE DISPLAY [P11-15-7] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .152DRIVE THRU ORDER CONFIRMATION BOARD (OCB) [P11-15-8] . . . . . . . . .152

PRINT A LIST BY STATION [P11-16] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .154PRINT A LIST BY PERIPHERAL [P11-17] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .155RS-232 WIRING DIAGRAMS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .157

TRAINING [P12] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .158

TRANSACTION OPTION [P12-1] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .158REPORT OPTION [P12-2] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .158PRINTING OPTION [P12-3] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .158

UTILITY [P13] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .159

DOWNLOAD PROGRAM [P13-1] OR AFTER [P12-1-2] . . . . . . . . . . . . . . . . . . . . . . . . .159DOWNLOAD APPLICATION PROGRAMS-All [P13-1-1] . . . . . . . . . . . . . . . . . .159DOWNLOAD APPLICATION PROGRAMS BY STATION GROUP [P13-1-2] / [P12-3] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .159DOWNLOAD APPLICATION PROGRAMS BY STATION NUMBER [P13-1-1-3] / [P12-3] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .159

Z1 AND PRE-POLL Z1 STRINGS [P13-2] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .160Z1 & PRE-POLL Z1 STRINGS # 1 [P13-2-1] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .160

Z2 AND PRE-POLL Z2 STRINGS [P13-3] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .162Z2 & PRE-POLL Z2 STRINGS # 1 [P13-3-1] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .163

PROGRAM PRINT [P13-4] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .165SYSTEM CONFIGURATION [P13-4-1] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .165 REPORT GROUPS AND TIME PERIOD [P13-4-2] . . . . . . . . . . . . . . . . . . . . . . . .165TAXES [P13-4-3] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .167SYSTEM OPTION [P13-4-4] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .168PLU [P13-4-5] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .169INVENTORY [P13-4-6] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .171MESSAGES [P13-4-7] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .171KEYBOARD SYSTEM [P13-4-8] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .173COUPON AND AUTO-COMBO [P13-4-9] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .174HUMAN RESOURCES [P13-4-10] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .175PERIPHERALS [P13-4-11] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .176TRAINING [P13-4-12] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .177Z & PRE-POLL STRINGS [P13-4-13] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .177

Page 8: NEC4000 Programming

Table of Contents

Table of Contents - 6

2350REF01

Page 9: NEC4000 Programming

S-Mode

S-Mode Menu Structure

S-Mode

S-Mode Menu Structure

S-MODE MENU STRUCTURE

●1 This will configure the memory based on the Memory Allocation Table.

● In programming, all Character fields are left justified and Integer and Numeric fields are right justified.

STATION NUMBER ASSIGNMENT [S1]

SYSTEM CONFIGURATION [S2]

● Changes here will not be broadcasted.

SYSTEM WIDE FEATURES [S2-1]

S-MODE1 STATION NUMBER ASSIGNMENT2 SYSTEM CONFIGURATION3 EDIT MEMORY ALLOCATION 1

4 KEY ASSIGNMENT5 DOWNLOAD PROGRAMS6 INITIALIZATION7 SYSTEM PASSWORD

S-MODE:SYSTEM CONFIGURATIONASSIGN STATION # (1-24) 99

S-MODE:SYSTEM CONFIGURATION1 SYSTEM WIDE FEATURE2 STATION GROUP3 STATION REGISTRATION4 MASTER & BACKUP ASSIGNMENT

S-MODE:SYSTEM WIDE FEATURE (1/2) STORE ID # abcdefgh STORE NAME XXXXXXXXXXXX DECIMAL POINT (0-3) 9 DECIMAL CHARACTER (0=".", 1=",") 9 CURRENCY MARK XXX CALENDAR FORMAT

(0=M/D/Y, 1=D/M/Y, 2=Y/M/D)9

SYSTEM DATE MM/DD/YYYY SYSTEM DAY

(0=SU,1=M,2=T,3=W,4=T,5=F,6=SA)9

SYSTEM TIME HH:MM # OF NETWORK RETRIES 9 # OF PRINTER RETRIES 9 ORDER # SYSTEM (0=COMMON, 1=LOCAL) 9 STARTING ORDER # 99999 TRACK1 # SYSTEM (0=AUTO, 1=MANUAL) 9 0-1 TRACK2 # SYSTEM (0=AUTO, 1=MANUAL) 9 0-1

2350REF01 NEC RSenCounter 4000 Reference Manual ◆ 1

Page 10: NEC4000 Programming

S-Mode

S-Mode Menu Structure

S-MODE:SYSTEM WIDE FEATURE (2/2) RECALL OWN TRACK # ORDER ONLY N RSC. DOWNLOADS FILES TO MODEM STA ONLY N

System Wide Feature [S2-1]: Programming fields and explanations

Field Descriptor Default Explanation

STORE ID # 1 8 character alpha/numeric

STORE NAME 12 character alpha/numeric

DECIMAL POINT (0-3) 2 Define the number of digits after the deci-mal point for Amount

CURRENCY MARK $ Currency Mark

CALENDAR FORMAT MM/DD/YY Define which calendar format to use

SYSTEM DATE Enter the system date

SYSTEM DAY Enter or assign the system day

SYSTEM TIME 00:00 Enter the system time

# OF NETWORK RETRY 2 # of retries to attempt before prompt

# OF PRINTER RETRY 2 # of retries to attempt before prompt

ORDER # SYSTEM? Local System wide common order # system or not

STARTING ORDER# 00001 Works in conjunction with Z Tran. Con-trol flag in system option-closing control.Local Order# system uses station number + last 3 digits of this number.

TRACK 1 # SYSTEM? AUTO INCR.

TRACK 2 # SYSTEM Manual

RECALL OWN TRACK# ORDER ONLY?

NO If YES, then a person who stored and the person who recalls the order must match. The order will be retrieved in FIFO unless designated.

RSC. DOWNLOADS FILES TO MODEM STA ONLY

NO If YES, then PC download will automati-cally download programs to all other sta-tions in the system.

2 ◆ NEC RSenCounter 4000 Reference Manual 2350REF01

Page 11: NEC4000 Programming

S-Mode

S-Mode Menu Structure

STATION GROUP [S2-2] (1/2)

● Maximum of 24 Station Groups are available

☞ Press [1] [ENTER] or [ENTER]

STATION 1 [S2-2-1]

* STATION 2 TO 24 are in the same format.

● Maximum of 24 Station Groups are available

● Station Group Descriptor will be used to group stations under the same descriptor name for the station group reports.

S-MODE:STATION GROUP# DESCRIPTOR99 ABCDEFGHIJKL 99=1-24

S-MODE:STATION GROUP STATION GROUP # (1-24) 99 1-24 STATION GROUP DESCRIPTOR XXXXXXXXXXXX

Station Group [S2-2]: Programming fields and explanations

Field Descriptor Default Explanation

STATION GROUP 1 STA GRP 1 Give a descriptor to this group

Not mandatory

STATION GROUP 24 Not mandatory

2350REF01 NEC RSenCounter 4000 Reference Manual ◆ 3

Page 12: NEC4000 Programming

S-Mode

S-Mode Menu Structure

STATION REGISTRATION [S2-3] Window 1

● Station 16-24 are on the second page.

☞ Press [1] [ENTER] or [ENTER]

STATION 1 [S2-3-1]

* STATION 1 TO 24 are in the same format.

S-MODE:STATION REGISTRATION

# DESCRIPTOR ACTIVE TYPE

99 ABCDEFGHIJKL Y XXXXXXXX

S-MODE:STATION REGISTRATION

STATION # (1-24) 99

STATION DESCRIPTOR XXXXXXXXXXXX

STATION GROUP (1-24) 99

ACTIVE Y

STARTING TRANSACTION # (1-9999) 9999

DEFAULT ORDER DESTINATION (0=NO DEST. 1=EATIN,2=TAKEOUT,3=TRK1,4=TRK2,5=DT)

9

STATION TYPE (0=TS, 1=QS CNTR, 2=DT OT, 3=DT CSHR, 4=DT OT CSHR)

9

SEND DT ORDER TO STATION (0-24) 99

[SERVE] BY THIS STA. STOPS SVC.TIMER Y

ENFORCE SERVE/PARK ENTRY Y

ENFORCE STORE TRACKING Y

SCREEN SAVER IN SEC (0-999) 999

Station Registration [S2-3-1]: Programming fields and explanations

Field Descriptor Default Explanation

STATION # 1 Allow entering number to access stations 2-24.

STATION DESCRIPTOR ‘STATION 1’ This descriptor will display on the lower left front display.

STATION GROUP 1 The report of this station will be in this group.

ACTIVE YES

STARTING TRANSACTION # 0001 Used in conjunction with the closing con-trol flag.

DEFAULT ORDER DESTINATION ()

0

STATION TYPE 0TABLE

SERVICE

This defines the Screen format.DT OT is the same as QS CNTR except DT OT enforces [SEND DTO].

4 ◆ NEC RSenCounter 4000 Reference Manual 2350REF01

Page 13: NEC4000 Programming

S-Mode

S-Mode Menu Structure

MASTER AND BACK UP ASSIGNMENT [S2-4]

SEND DRIVE THROUGH ORDER TO STATION

This is not available in TBL SVC. Define the destination station number to which the order is sent.

[SERVE] BY THIS STA. STOPS SVC.TIMER

NO If YES, then this station’s {SERVE} key to bump off the DT Order will be used to stop DT Service Timer

ENFORCE SERVE/PARK ENTRY NO Must enter either SERVE or PARK key before starting the new order.

ENFORCE STORE TRACKING NO Tender key entry is prohibited if this is YES

SCREEN SAVER IN SEC. 180

S-MODE:MASTER & BACK UP ASSIGNMENT

SYSTEM

MASTER STATION # (1-24) 99

BACK UP STATION # (0-24) 99

TRACKING:

MASTER STATION # (1-24) 99

BACK UP STATION # (0-24) 99

Master and Backup Assignments [S2-4]: Programming fields and explanations

Field Descriptor Default Explanation

SYSTEM:

MASTER STATION # STATION 1 Holds clock data, product projection, Z1 & Z2 Prepoll Area.

BACK UP STATION # 0

TRACKING:

MASTER STATION # STATION 1 The number of the order Track File.Credit Card Tran. File

BACK UP STATION # 0

Station Registration [S2-3-1]: Programming fields and explanations

Field Descriptor Default Explanation

2350REF01 NEC RSenCounter 4000 Reference Manual ◆ 5

Page 14: NEC4000 Programming

S-Mode

S-Mode Menu Structure

EDIT MEMORY ALLOCATION TABLE [S3]

COMMON CONFIGURATION [S3-1]

S-MODE1 COMMON CONFIGURATION2 SYSTEM MASTER3 TRACKING MASTER4 LOCAL STATION

REMAININGMEMORY

2321968

S-MODE:MEMORY ALLOCATION-COMMON CONFIGURATION (1/3) # OF PLU PROPERTY 9999 5 digits internally # OF PLU 9999 5 digits internally # OF PLU SHIFT 999 # OF PRICE TABLE 999 # OF CONDIMENT TABLE 999 # OF CONDIMENT CHAIN 999 # OF LINKED PLU TABLE 999 # OF MAJOR GROUP 99 # OF SUB GROUP 999 # OF PROD. MIX GROUP 99 # OF EMPLOYEE 999 # OF CASHIER 999 # OF KITCHEN PRINTER TABLE 99 # OF MACRO 99 # OF TLU 999 # OF MLU 999

S-MODE:MEMORY ALLOCATION-COMMON CONFIGURATION (2/3) # OF COUPON 999 # OF AUTO-COMBO TABLE 99 # OF SPECIAL ITEM STOCK 999 # OF RECEIPT DESCRIPTOR 999 # OF TIME PERIOD 999TIME PERIOD: MAJOR GROUP YTIME PERIOD: EAT-IN YTIME PERIOD: TAKE-OUT YTIME PERIOD: TRACK 1 YTIME PERIOD: TRACK 2 YTIME PERIOD: DRIVE THRU YTIME PERIOD: DRIVE THRU SVC TIME Y # OF SHIFT IN A DAY 9 # OF ITEM/TRANS. 999 # OF PAID ORDER RECALL 99 # OF CASH PULL 99

S-MODE:MEMORY ALLOCATION-COMMON CONFIGURATION (3/3) GRAPHIC PRINTER LOGO N

6 ◆ NEC RSenCounter 4000 Reference Manual 2350REF01

Page 15: NEC4000 Programming

S-Mode

S-Mode Menu Structure

Common Configurations [S3-1]: Programming fields and related flags. Page 1/3

Field Descriptor Default Explanation

# OF PLU PROPERTY 20

# OF PLU 500

# OF PLU SHIFT 20

# OF PRICE TABLE 10

# OF CONDIMENT TABLE 50

# OF CONDIMENT CHAIN 10

# OF LINKED PLU TABLE 10

# OF MAJOR GROUP 20

# OF SUB GROUP 50

# OF PROD. MIX GROUP 5

# OF EMPLOYEE 20

# OF CASHIER 10

# OF KITCHEN PRINTER TABLE 5

# OF MACRO 30

# OF TLU 10

# OF MLU 30

2350REF01 NEC RSenCounter 4000 Reference Manual ◆ 7

Page 16: NEC4000 Programming

S-Mode

S-Mode Menu Structure

Common Configurations [S3-1]: Programming fields and related flags. Page 2/3

Field Descriptor Default Explanation

# OF COUPON 20

# OF AUTO-COMBO TABLE 10

# OF SPECIAL ITEM STOCK 0

# OF RECEIPT DESCRIPTOR 0

# OF TIME PERIOD 24 (MULTIPLE OF 12)

TIME PERIOD: MAJOR GROUP YES

TIME PERIOD: EAT-IN NO

TIME PERIOD: TAKE-OUT NO

TIME PERIOD: TRACK 1 NO

TIME PERIOD: TRACK 2 NO

TIME PERIOD: DRIVE THRU NO

TIME PERIOD: DRIVE THRU SVC TIME

NO

# OF SHIFT IN DAY 0 Same format as Financial

# OF ITEM/TRANS. 50

# OF PAID ORDER RECALL 5

# OF CASH PULL 10 =BANK DEPOSIT

Common Configurations [S3-1]: Programming fields and related flags. Page 3/3

Field Descriptor Default Explanation

GRAPHIC PRINTER LOGO NO

8 ◆ NEC RSenCounter 4000 Reference Manual 2350REF01

Page 17: NEC4000 Programming

S-Mode

S-Mode Menu Structure

SYSTEM MASTER [S3-2]

● Note 1:Pre-Poll of Z1 or Z2 will not be allowed more than the number of times set in the S-Mode Mem-ory Allocation. Pre-polled data is polled and cleared by either the PC or manually at the NEC RSenCounter 4000.Pre-polled Data is polled in FIFO fashion.

TRACKING MASTER [S3-3]

S-MODE:MEMORY ALLOCATION-SYSTEM MASTER CLOCK DATA FOR PAY PERIOD

(0=NO,1=WK,2=BI-WK,3=SEMI-MO,4=MO)9

USE PRODUCT PROJECTIONS N # OF Z1/Z2 PRE-POLL AREA 0 KVS SERVICE TIME REPORT AREA N # OF BUSINESS FLASH REPORT 99 # OF CTS CONSOLIDATION AREA 9999

System Master [S3-2]: Programming fields and explanations

Field Descriptor Default Explanation

CLOCK DATA FOR PAY PERIOD(0=NO,1=WK,2=BI-WK,3=SEMI-MO.4=MO.)

WK Provide a maximum of WK=7+7, B-WK=14+7.SEMI-MO.=16+7 DAYS punch record area.# OF EMPLOYEES x 10 x14/21/23 +MM/DD/YYYY.

USE PRODUCT PROJECTIONS NO

# OF Z1/Z2 PRE-POLL AREANote 1)

0 This will reserve the area for # of Z1 or Z2 pre-poll.Need at least 1 for PC polling

KVS SERVICE TIME REPORT AREA

N If YES, then reserve 108 periods x # OF Z1/Z2 PRE-POLL AREA

# OF BUSINESS FLASH REPORT 1-99 Report is created when System wide Z1 Financial is taken at the System Master.

# OF CTS CONSOLIDATION AREA

0-9999 0=Disabled

S-MODE:MEMORY ALLOCATION-TRACKING MASTER

# OF ORDER TRACK 9999

# OF CREDIT CARD TRACKING FILES 1800

2350REF01 NEC RSenCounter 4000 Reference Manual ◆ 9

Page 18: NEC4000 Programming

S-Mode

S-Mode Menu Structure

LOCAL STATION [S3-4]

● This information will not be downloaded to other station. In short, each station has to be pro-grammed separately.

S-MODE:MEMORY ALLOCATION-LOCAL STATION

# OF DRIVE –THRU ORDER 99

# OF CLOSED TRANS. SUMMARY (CTS) 9999

# OF KEY STROKE HISTORY 99999

AREA FOR TRANSACTION LOG 9999

AREA FOR SYSTEM LOG 9999

Location Station [S3-4]: Programming fields and related flags.

Field Descriptor Default Explanation

# OF DRIVE-THRU ORDER 0

# OF CLOSED TRANS. SUMMARY (CTS)

0

# OF KEY STROKE HISTORY 0

AREA FOR TRANSACTION LOG (256 BYTES) x

0

AREA FOR SYSTEM LOG (256 BYTES) x

0

10 ◆ NEC RSenCounter 4000 Reference Manual 2350REF01

Page 19: NEC4000 Programming

S-Mode

S-Mode Menu Structure

KEY ASSIGNMENT [S4]

●1 Corresponding keyboard level’s function key descriptor. Reflect this keyboard level on Line 20 Status Line.

☞ Press [1] [Enter]

KEY BOARD LEVEL 1 SELECTED [S4-1]

☞ Press [LOC. 1]

S-MODE:KEY ASSIGNMENT

# DESCRIPTOR INTERNAL NAME

9 ABCDEFGHIJKL KEY BRD LVL X

S-MODE:KEY ASSIGNMENT

# DESCRIPTOR INTERNAL NAME

1 BREAKFAST KEY BRD LVL 1 1

2 LUNCH KEY BRD LVL 2

3 DINNER KEY BRD LVL 3

4 SUN. BRUNCH KEY BRD LVL 4

5 MANAGER KEY BRD LVL 5

S-MODE:KEY ASSIGNMENT KB LEVEL 1 BREAKFAST

PRESS THE KEY TO BE PROGRAMMED

Key Assignment [S4-1]: Programming fields and related flags.

Field Descriptor Default Explanation

# Select Keyboard level

DESCRIPTOR

INTERNAL NAME

2350REF01 NEC RSenCounter 4000 Reference Manual ◆ 11

Page 20: NEC4000 Programming

S-Mode

S-Mode Menu Structure

KEYBOARD LEVEL PROGRAMMING [S4-1-1]

☞ Press [EXIT]

KEYBOARD LEVEL PROGRAMMING [S4-1-1-EXIT]

S-MODE:KEY ASSIGNMENT – KB LEVEL 1 BREAKFASTABCCURRENT:CHEESE BURGEREXT 12345678901234

Display Level & DescriptorDisplay current information

NEW ASSIGNMENT: KEY LOC. 001KEY TYPE (0, 1-6) 1 CODE # xxxxxxxxxxxxxxxx 12345678901234 xxx..DESCRIPTOR

CODE# DESCRIPTOR KEY TYPE 00000000000001 TOMATO 1=PLU 00000000000002 LETTUCE 2=PLU SFT 00000000000004 PICKLES 3=FUNC 00000000000005 MAYO 4=MACRO 12345678901233 HAMBURGER 5=TLU 12345678901234 CHEESE BURGER 6=MLU 12345678901235 HOT DOG 12345678901236 GRILLED CHICKEN 0=TO MENU 12345678901237 ROAST BEEF 12345678901238 CHICKEN SANDWICH

S-MODE:KEY ASSIGNMENT KB LEVEL 1 BREAKFAST

PRESS THE KEY TO BE PROGRAMMED

PREVIOUS KEY ASSIGNMENT: LOC. 001KEY TYPE PLUCODE # 12345678901234DESCRIPTOR CHEESE BURGEREXT

Key Assignment [S4-1-1]: Programming fields and related flags.

Field Descriptor Default Explanation

KB LEVEL

(DESCRIPTOR) Display KB Level Descriptor

CURRENT: Current Key Descriptor

(CODE #) Current Key Code #

NEW ASSIGNMENT:KEY LOC. Physical Key Location pressed (Verti-cally counted from upper left.

KEY TYPE

CODE # Key Code #

12 ◆ NEC RSenCounter 4000 Reference Manual 2350REF01

Page 21: NEC4000 Programming

S-Mode

S-Mode Menu Structure

● Note 2: If PLU NO. is not found (= not registered), then prompt

● [1] The cursor will go to [S4-1-1] CODE # field (blank field).LINE 6 CODE # 0

● [2] create a new INACTIVE PLU by this number and go to [S4-1-1] CODE# field.LINE 6 CODE # NEW PLU 12345678901234

DOWNLOAD PROGRAMS [S5]

●1 System software is the Flash EPROM program.

●2 System configuration in all programs in [S2] System Configuration programming.

●3 Memory allocation (COMMON AREA) can be downloaded. If there is an allocation error such as a lack of memory at the downloaded station, then display “INCORRECT MEMORY ALLOCATION” error at the downloaded station.

●4 Master and/or Local Areas have to be manually allocated at the each station according to the system configuration.

☞ [S5-1], [S5-2], [S5-3], or [S5-4]

SYSTEM SOFTWARE [S5-1]

● Station list may be provided upon request.

PLU# NOT FOUND!

SELECT

1 TRY ANOTHER PLU #

2 CREATE NEW PLU

S-MODE:DOWNLOAD PROGRAMS

1 SYSTEM SOFTWARE 1

2 SYSTEM CONFIGURATION 2

3 MEMORY ALLOCATION (COMMON COFIG. ONLY) 3 4

4 KEYBOARD INFORMATION

5 ALL OF ABOVE EXCEPT SYSTEM SOFTWARE

S-MODE:SYSTEM SOFTWARE

1 SYSTEM WIDE

2 STATION GROUP

3 RANGE

2350REF01 NEC RSenCounter 4000 Reference Manual ◆ 13

Page 22: NEC4000 Programming

S-Mode

S-Mode Menu Structure

SYSTEM SOFTWARE-BY STATION GROUP [S5-1-2]

SYSTEM SOFTWARE-BY RANGE [S5-1-3]

INSTALLATION PROCEDURE

1. STATION NUMBER ASSIGNMENT [S1]. (Boot ROM may hold only [S1] menu)2. In S-MODE, hold [1], [2], or [3] depending on communication speed for downloading system soft-

ware from PC (RSConnect.exe)

3. Download system software to Master Station through RSConnect.exe.

4. Upon completion, turn off the power and turn on the power with [EXIT] key in S-Mode.

5. SYSTEM CONFIGURATION [S2]

6. SYSTEM WIDE FEATURE [S2-1]

7. STATION GROUP [S2-2] (Not mandatory)8. STATION REGISTRATION [S2-3] (make all stations active to be downloaded)

9. MASTER AND BACKUP ASSIGNMENT [S2-4]

10. Connect each station.

11. Download System Software from the Master station to satellite stations.

a) At each station to be downloaded, hold [7] and turn the power on in S-Mode

b) At each station to be downloaded, enter the station number with [ENTER], e.g. [0][2][ENTER]

for the station number 2.

c) At the master, perform Download System Software-All Stations [S5-1-1] to start

downloading the System Software.

12. EDIT MEMORY ALLOCATION [S3]

13. KEY ASSIGNMENT [S4] (Not mandatory)14. DOWNLOAD SYSTEM CONFIGURATION TO STATIONS [S5-2] from the Master Station

15. DOWNLOAD MEMORY ALLOCATION (COMMON AREA) TO STATIONS [S5-3] from the

Master Station

The memory requirement at each station is calculated based on System Configuration [S2] accordingly.

16. DOWNLOAD KEY BOARD INFORMATION [S5-4]. (Not mandatory)17. At each station perform Station Registration [S3] to configure Local and/or Masters accordingly.

RUN THE SYSTEM TEST SOFTWARE

1. Hold [0] and turn the power on in S-MODE.

S-MODE:SYSTEM SOFTWARE-STA. GROUP

DOWNLOAD TO STATION GROUP (1-24) 00

S-MODE:SYSTEM SOFTWARE-RANGE

DOWNLOAD TO STATION NUMBER:

START (1-24) 00

END (1-24) 00

14 ◆ NEC RSenCounter 4000 Reference Manual 2350REF01

Page 23: NEC4000 Programming

S-ModeS-Mode Menu Structure

INITIALIZATION [S6]

●1 Pending orders include interrupted orders.

● Display the long message “INSTALLED” in the error message window after 10, 11, and 12.

CLEAR RAM AND INSTALL DEFAULT PROGRAM [S6-1]

CLEAR TOTAL AND COUNTERS [S6-2]

[S6-3] to [S6-9]● [S6-3] to [S6-9] are same as above in format.

● Default value to the prompt is “NO”

INSTALL DEFAULT MESSAGES [S6-10]

1 CLEAR RAM AND INSTALL DEFAULT PROGRAM2 CLEAR TOTALS AND COUNTERS

3 CLEAR ORDER TRACKING,P.O.R., & PENDING ORDERS 1

4 CLEAR PRODUCT PROJECTIONS5 CLEAR TIME KEEPING6 CLEAR CREDIT TRACKING FILES

9 CLEAR BIT IMAGE (LOGO) ON RECEIPT/CHECK10 INSTALL DEFAULT MESSAGES11 INSTALL DEFAULT FUNCTION KEYS12 INSTALL DEFAULT KEY BOARD

CLEAR RAM AND INSTALL DEFAULT PROGRAMARE YOU SURE? NO

CLEAR TOTAL AND COUNTERS

ARE YOU SURE? NO

1 ALL MESSAGES

2 SCREEN MESSAGE (SHORT)

3 SCREEN MESSAGE (LONG)

4 ERROR MESSAGE

5 RECEIPT/CHECK SYSTEM MESSAGE

6 RECEIPT/CHECK HEADER AND FOOTER

7 CREDI CARD AGREEMENT MESSAGE (CHARGE)

8 CREDIT CARD AGREEMENT MESSAGE (CREDIT)

9 GUEST CHECK TRAIL MESSAGE

10 KITCHEN PRINTER MESSAGE

11 REPORT MESSAGE

2350REF01 NEC RSenCounter 4000 Reference Manual ◆ 15

Page 24: NEC4000 Programming

S-ModeS-Mode Menu Structure

ALL MESSAGES [S6-10-1]

● This will update all of 2 to 5.

SCREEN SYSTEM DESCRIPTOR [S6-10-2]

RECEIPT/CHECK SYSTEM DESCRIPTOR [S6-10-5]

RECEIPT/CHECK HEADER AND FOOTER [S6-10-6]

CREDIT CARD AGREEMENT MESSAGE (CHARGE) [S6-10-7]

CREDIT CARD AGREEMENT MESSAGE (CREDIT) [S6-10-8]

GUEST CHECK TRAIL MESSAGE [S6-10-9]

KITCHEN PRINTER MESSAGE [S6-10-10]

REPORT MESSAGE [S6-10-11]

INSTALL DEFAULT FUNCTION KEYS [S6-11]

● For those messages that require # will have its own unique record number to be accessed in the memory.

INSTALL DEFAULT KEYBOARD [S6-12]● After the Default Keyboard Installation, it will display the message: “DEFAULT KEY BOARD

INSTALLED”.

S-MODE:INSTALL DEFAULT SCREEN MESSAGE (SHORT) ENTER # TO ADD OR REPLACE (999 REPLACE AND ADD ALL)

999

1 S-MODE:INSTALL DEFAULT RECEIPT/CHECK SYSTEM MESSAGE 2 ENTER # TO ADD OR REPLACE 9993 (999 REPLACE AND ADD ALL)45

1 S-MODE:INSTALL DEFAULT REPORT MESSAGE2 ENTER # TO ADD OR REPLACE 9993 (999 REPLACE AND ADD ALL)45

1 S-MODE:INSTALL DEFAULT FUNCTION KEYS2 ENTER # TO ADD OR REPLACE 9993 (999 REPLACE AND ADD ALL)45

16 ◆ NEC RSenCounter 4000 Reference Manual 2350REF01

Page 25: NEC4000 Programming

S-ModeS-Mode Menu Structure

SYSTEM PASSWORD [S7]

SYSTEM TEST [S8]

● Hold [0] and turn power on in S-Mode.

S-MODE:SYSTEM PASSWORD ENTER YOUR SYSTEM PASSWORD 9999 Factory Default

value is 9999SUPPORT PHONE # ____________CONTACT 1 ____________CONTACT 2 ____________

TEST PROGRAM 06/09/00(FRI) 20:06:55 01.RAM NON DESTRUCTIVE 16.EX-RAM NON DESTRUCTIVE 02.RAM WRITE FOR M.LOSS 17.EX-RAM WRITE FOR M.LOSS 03.RAM LOSS TEST 18.EX-RAM LOSS TEST 04.RS232C PORT 1 19.EX-RS232C PORT 4 05.RS232C PORT 2 20.EX-RS232C PORT 5 06.RS232C PORT 3 21.CARD READER – OPTION 07.LAN 22.CLERK KEY – OPTION 08.OPERATION DISPLAY 23. 09.CUSTOMER DISPLAY 24. 10.KEYBOARD 25. 11.KEYLOCK SWITCH 26. 12.REAL TIME CLOCK 27.BUZZER 13.CASH DRAWER A OPEN 28.POWER LED 14.CASH DROWER B OPEN 29.CHECK SUM 15.FLASH MEMORY 30.

2350REF01 NEC RSenCounter 4000 Reference Manual ◆ 17

Page 26: NEC4000 Programming

S-ModeS-Mode Menu Structure

- For Your Notes -

18 ◆ NEC RSenCounter 4000 Reference Manual 2350REF01

Page 27: NEC4000 Programming

P-MODEP-MODE MENU STRUCTURE

P-MODE

P-MODE MENU STRUCTURE

P-MODE MENU STRUCTURE

EDIT SYSTEM CONFIGURATION [P1]

SYSTEM WIDE FEATURES [P1-1]

P-MODE: EDIT SYSTEM CONFIGURATION1 EDIT SYSTEM CONFIGURATION2 REPORT GROUPS AND TIME PERIODS3 TAXES4 SYSTEM OPTION5 PLU6 INVENTORY7 MESSAGES8 KEYBOARD SYSTEM9 COUPON AND AUTO-COMBO10 HUMAN RESOURCES11 PERIPHERALS12 TRAINING13 UTILITY

P-MODE: EDIT SYSTEM CONFIGURATION1 SYSTEM WIDE FEATURE2 STATION GROUP3 STATION REGISTRATION4 MASTER & BACKUP ASSIGNMENT5 DOWNLOAD

P-MODE:SYSTEM WIDE FEATURE (1/2) STORE ID # abcdefgh STORE NAME XXXXXXXXXXXX DECIMAL POINT (0-3) 9 DECIMAL CHARACTER (0=".", 1=",") 9 CURRENCY MARK XXX CALENDAR FORMAT(0=M/D/Y, 1=D/M/Y, 2=Y/M/D)

9

SYSTEM DATE MM/DD/YYYY SYSTEM DAY(0=SU,1=M,2=T,3=W,4=T,5=F,6=SA)

9

SYSTEM TIME HH:MM # OF NETWORK RETRIES 9 # OF PRINTER RETRIES 9 ORDER # SYSTEM (0=COMMON, 1=LOCAL) 9STARTING ORDER # 99999 TRACK1 # SYSTEM (0=AUTO, 1=MANUAL) 9 0-1 TRACK2 # SYSTEM (0=AUTO, 1=MANUAL) 9 0-1

P-MODE:SYSTEM WIDE FEATURE (2/2) RECALL OWN TRACK # ORDER ONLY N RSC. DOWNLOADS FILES TO MODEM STA ONLY N

2350REF01 NEC RSenCounter 4000 Reference Manual ◆ 19

Page 28: NEC4000 Programming

P-MODEP-MODE MENU STRUCTURE

System Wide Features [P1-1]: Programming fields and explanations

Field Descriptor Default Explanation

STORE ID # 0 8 character alpha/numeric

STORE NAME 12 character alpha/numeric

DECIMAL POINT 2 Define the number of digits after the decimal point for amount

DECIMAL CHARACTER .

CURRENCY MARK $ Currency Mark

CALENDAR FORMAT M/D/Y Define which calendar format to use.

SYSTEM DATE 01/01/2000 Enter the system date

SYSTEM DAY 0 Enter or assign the system day

SYSTEM TIME 00:00 Enter the system time. (13:00 = 1:00 PM)Internally 4 digits00:00 is a valid time

# OF NETWORK RETRY 2 Number of retries to attempt before prompt.

# OF PRINTER RETRY 2 Number of retries to attempt before prompt.

ORDER # SYSTEM LOCAL System wide common order # system or not

STARTING ORDER # 00001 Works in conjunction with Z Tran. OPTION flag in system option-closing OPTION.Local= Number system uses the station num-ber + last 3 digit of this number.

TRACK 1 # SYSTEM AUTO INCR.

TRACK 2 # SYSTEM MANUAL ENTRY

RECALL OWN TRACK # ORDER ONLY

NO If YES, then a person who stored and the per-son who recalls the order must match. Order will be retrieved in FIFO unless designated.

RSC. DOWNLOADS FILES TO MODEM STA ONLY

NO If YES, then the PC download will automati-cally download programs to all other stations in system.

20 ◆ NEC RSenCounter 4000 Reference Manual 2350REF01

Page 29: NEC4000 Programming

P-MODEP-MODE MENU STRUCTURE

STATION GROUP [P1-2]

● Maximum of 24 Station Groups are available

☞ [1][ENTER] or [ENTER]

STATION 1 [P1-2-1]

STATION REGISTRATION [P1-3]

● Station 16-24 are on the second page.

☞ [1][ENTER] or [ENTER]

P-MODE:STATION GROUP# DESCRIPTOR

99 ABCDEFGHIJKL 99=1-24

Station Group [P1-2]: Programming fields and explanations

Field Descriptor Default Explanation

# 1 STATION GROUP #

DESCRIPTOR STA GRP 1 STATION GROUP DESCRIPTOR

P-MODE:STATION GROUPSTATION GROUP # (1-24) 99 1-24STATION GROUP DESCRIPTOR XXXXXXXXXXXX

Station 1 [P1-2-1]: Programming fields and explanations

Field Descriptor Default Explanation

STATION GROUP # 1

STATION GROUP DESCRIPTOR STA GRP 1 Give a descriptor to this group

P-MODE:STATION REGISTRATION# DESCRIPTOR ACTIVE TYPE SEND TO99 ABCDEFGHIJKL Y XXXXXXXXXX ->99 99=1-24

Station Registration [P1-3]: Programming fields and explanations

Field Descriptor Default Explanation

# 1 Allow entering number to access the station.

STATION DESCRIPTOR ‘STATION 1’

TYPE TABLE SERVICE

SEND TO 0 A station number to which this Station send DT order.

2350REF01 NEC RSenCounter 4000 Reference Manual ◆ 21

Page 30: NEC4000 Programming

P-MODEP-MODE MENU STRUCTURE

STATION 1 [P1-3-1]

* STATION 1 TO 24 are in the same format.

P-MODE:STATION REGISTRATION STATION # (1-24) 99 STATION DESCRIPTOR XXXXXXXXXXXX STATION GROUP (1-24) 99 ACTIVE Y STARTING TRANSACTION # (1-9999) 9999 DEFAULT ORDER DESTINATION (0=NO DEST. 1=EATIN,2=TAKEOUT,3=TRK1,4=TRK2,5=DT)

9

STATION TYPE (0=TS,1=QS CNTR) 9 2=DT OT, 3=DT CSHR, 4=DT OT CSHR) SEND DT ORDER TO STATION (0-24) 99 [SERVE] BY THIS STA. STOPS SVC.TIMER Y ENFORCE SERVE/PARK ENTRY Y ENFORCE STORE TRACKING YSCREEN SAVER IN SEC (0-999) 999# OF BEEPS IN PRINTER ERROR 99DISABLE ERROR TONE NDISABLE KEY TOUCH TONE N

Station 1 [P1-3-1]: Programming fields and explanations

Field Descriptor Default Explanation

STATION # 1 Allow entering number to access another station.

STATION DESCRIPTOR ‘STATION 1’

STATION GROUP 1 The report of this station will be in this group.

ACTIVE Y

STARTING TRANSACTION # 0001 Used in conjunction with the closing OPTION flag.

DEFAULT ORDER DESTINATION 0

STATION TYPE TABLE SERVICE This defines the Screen formatDT OT is same as QS CNTR except DT OT enforce [SEND DTO] and STOR/RECALL are N/A.

SEND DT ORDER TO SATION This is not available in TBL SVC.Define the destination Station # where the order sent to.

SERVE BY THIS STA. STOPS SVC. TIMER

N0 If Y, then this station’s {SERVE} key to bump off the DT Order will be used to stop DT Service Timer

ENFORCE SERVE/PARK ENTRY NO Must enter either SERVE or PARK key before starting the new order.

ENFORCE STORE TRACKING NO Tender key entry is prohibited if this is Y

SCREEN SAVER IN SEC 180

# OF BEEPS IN PRINTER ERROR 0-99

DISABLE ERROR TONE N Enables or disables tone when error con-dition is encountered.

DISABLE KEY TOUCH TONE N Disables beeps when keys are depressed.

22 ◆ NEC RSenCounter 4000 Reference Manual 2350REF01

Page 31: NEC4000 Programming

P-MODEP-MODE MENU STRUCTURE

MASTER AND BACK UP ASSIGNMENT [P1-4]

DOWNLOAD SYSTEM CONFIGURATION [P1-5][P1-5] is the same as DOWNLOAD APPLICATION PROGRAMS BY STATION GROUP [P13-1-2] / [P12-3] on page 159.

P-MODE:MASTER & BACK UP ASSIGNMENT SYSTEM:

MASTER STATION # (1-24) 99BACK UP STATION # (0-24) 99

TRACKING:MASTER STATION # (1-24) 99BACK UP STATION # (0-24) 99

Master and Back Up Assignment: Programming fields and explanations

Field Descriptor Default Explanation

SYSTEM :

MASTER STATION # 1 Holds Clock Date, Z1 & Z2 Prepoll Area, and Closed Transaction File (TBD)

BACK UP STATION # 0 No Backup for Default

TRACKING:

MASTER STATION # 1 The number of the order track file.Credit Card Tran. File

BACK UP STATION # 0 No Backup for Default

2350REF01 NEC RSenCounter 4000 Reference Manual ◆ 23

Page 32: NEC4000 Programming

P-MODEP-MODE MENU STRUCTURE

REPORT GROUPS AND TIME PERIODS [P2]

MAJOR GROUP [P2-1]MAJOR GROUP 1/7 –7/7 (Maximum)

☞ [ENTER]

MAJOR GROUP RECORD [P2-1-1]

P-MODE :REPORT GROUPS AND TIME PERIODS1 MAJOR GROUP2 SUB GROUP3 PRODUCT MIX GROUP4 TIME PERIOD : AUTO CONFIGURATION5 TIME PERIOD : MANUAL CONFIGURATION

P-MODE:MAJOR GROUP# DESCRIPTOR ON RCPT. ON T.P. REPORT99 ABCDEFGHIJKL YES YES 99=1-99

Major Group [P2-1]: Programming fields and explanations Allocatable to Max 99 groups

Field Descriptor Default Explanation

# 1 Enter the product Major Group number to access.

DESCRIPTOR Major Group descriptor

ON RCPT. Y/N If Y, then this Major Group will print on the Receipt

ON T.P. REPORT If Y, then this Major Group will print on the Time Period Report

SALES REPORT 0-9 Reflect on Cashier Rep. & Cashier Sales Rep.

P-MODE:MAJOR GROUP MAJOR GROUP # 99 DESCRIPTOR XXXXXXXXXXXX ON RECEIPT Y PRINT ON THE TIME PERIOD REPORT Y

Major Group Record [P2-1-1]: Programming fields and explanationsAllocatable to Max 99 groups

Field Descriptor Default Explanation

MAJOR GROUP # Enter number to jump to another Major Group record

DESCRIPTOR MAJ GRP 1

ON RECEIPT N Print Major Group on the receipt

PRINT ON THE TIME PERIOD REPORT

N Reflect this group on the Time Period Report or not

24 ◆ NEC RSenCounter 4000 Reference Manual 2350REF01

Page 33: NEC4000 Programming

P-MODEP-MODE MENU STRUCTURE

SUB GROUP [P2-2]Window 1 Page 1/63 – 63/63 (Maximum 999 Groups)

☞ [1][ENTER]

SUB GROUP [P2-2-1]

P-MODE:SUB GROUP# DESCRIPTOR TO MAJ GRP. SALES REPORT

999 ABCDEFGHIJKL 01 XXXXXXXXXXXX 9 999=MEMORY ALLOC.SALES REPORT=0-9

Sub Group [P2-2]: Programming fields and explanationsAllocatable to Max 999 groups

Field Descriptor Default Explanation

# 1 Enter the product Sub Grp.number to access.

DESCRIPTOR

TO Maj Grp. number Reporting to

MAJ GRP. Maj Grp.’s descriptor Reporting to

SALES REPORT Reflect on Cashier Rep.& Cashier Sales Rep.

P-MODE:SUB GROUP SUB GROUP # 999 DESCRIPTOR XXXXXXXXXXXX REPORT TO MAJOR GROUP 99 REPORT TO CSHR/SVR SALES REPORT 9 (0-9,0=NO REP)

Sub Group [P2-2-1]: Programming fields and explanationsAllocatable to Max 999 groups

Field Descriptor Default Explanation

SUB GROUP # Enter another sub group number to access from here.

DESCRIPTOR SUB GRP 1

REPORT TO MAJOR GROUP 1

REPORT TO CSHR/SVR SALES REPORT

0 Enter the sales report number this group will report to. The sales report descrip-tors are programmed in #119-127, Report Messages, in P-Mode.

2350REF01 NEC RSenCounter 4000 Reference Manual ◆ 25

Page 34: NEC4000 Programming

P-MODEP-MODE MENU STRUCTURE

PRODUCT MIX GROUP [P2-3]Window 1(Maximum 99 Groups)

☞ [1=PRODUCT MIX GROUP # 1][ENTER]

PRODUCT MIX GROUP [P2-3-1]

P-MODE:PRODUCT MIX GROUP# DESCRIPTOR PIECES UNIT99 ABCDEFGHIJKL 88 /XXXX

Product Mix Group [P2-3]: Programming fields and explanationsAllocatable to Max 99 groups

Field Descriptor Default Explanation

# 1 Enter the product mix group number to access.

DESCRIPTOR

PIECES

UNIT “/” + Unit descriptor

P-MODE:PRODUCT MIX GROUP PRODUCT MIX GROUP # 99 DESCRIPTOR XXXXXXXXXXXX PIECE PER UNIT 999 UNIT DESCRIPTOR XXXX

Product Mix Group [P2-3-1]: Programming fields and explanationsAllocatable to Max 99 groups

Field Descriptor Default Explanation

PRODUCT MIX GROUP # Enter number to access another record.

DESCRIPTOR PROD MIX GRP PROD. MIX 1 (to 255)

PIECE PER UNIT 1 Forms quantity per whole unit.

UNIT DESCRIPTOR 4 characters descriptor.

26 ◆ NEC RSenCounter 4000 Reference Manual 2350REF01

Page 35: NEC4000 Programming

P-MODEP-MODE MENU STRUCTURE

TIME PERIODS AUTO CONFIGURATION [P2-4]

TIME PERIOD BY MANUAL CONFIGURATION [P2-5]MAX 108 PERIODS PAGE1/9 –9/9

● Hour in 24 hour clock.

● If both FROM and TO time is 00:00, then this period will be ignored.

P-MODE:TIME PERIOD AUTO CONFIGURATION TIME PERIOD BY EVERY (15,30,60MIN.) 99 STARTING TIME FROM (HH:00) HH:00 HH in 24 hour clock ENABLE AUTO CONFIGURATION Y

Time Periods Auto Configuration [P2-4]: Programming fields and explanationsAllocatable to Max 99 groups

Field Descriptor Default Explanation

TIME PERIOD BY EVERY 00

STARTING TIME FROM 00:00 System will configure the time period such as 06:00 to :29 …and etc.

ENABLE AUTO CONFIGURATION N

P-MODE:MANUAL CONFIGURATION (1/9)-(Check Memory Allocation)Accept 00:00

EXCL. FROM TOTAL1 FROM HH:MM TO HH:MM N2 FROM HH:MM TO HH:MM N3 FROM HH:MM TO HH:MM N4 FROM HH:MM TO HH:MM N5 FROM HH:MM TO HH:MM N6 FROM HH:MM TO HH:MM N7 FROM HH:MM TO HH:MM N8 FROM HH:MM TO HH:MM N9 FROM HH:MM TO HH:MM N10 FROM HH:MM TO HH:MM N11 FROM HH:MM TO HH:MM N12 FROM HH:MM TO HH:MM N

Time Period by Manual Configuration [P2-5]: Programming fields and related flags

Field Descriptor Default Explanation

999 Max 108 periods

FROM 00:00 Starting time of this Period

TO 00:00 Ending time of this Period.

EXCLU. FROM TOTAL N If “Y”, then do not include in the total at the end of the report.

2350REF01 NEC RSenCounter 4000 Reference Manual ◆ 27

Page 36: NEC4000 Programming

P-MODEP-MODE MENU STRUCTURE

TAXES [P3]

TAX CONFIGURATION [P3-1]

TAX 1 [P3-1-1]

TAX TYPE = [TAX %]

● *1 = Skip on TAX TYPE=1 and 2 Previously programmed figures in fields may remain as it is when TAX TYPE is changed from 0 to 1, however it will be ignored.

● *2 = These flags are used when SYSTEM OPTION –RECEIPT FORMAT ; ‘PRINT ONLY SUM OF ALL TAXES=N’

P-MODE :1 TAX CONFIGURATION2 TAX TABLE PROGRAMMING3 TAX OPTION

P-MODE:TAX CONFIGURATION# DESCRIPTOR TYPE RATE(%)9 ABCDEFGHIJKL TABLE 1 99.99 9=1-6

Tax Configuration [P3-1]: Programming fields and explanations

Field Descriptor Default Explanation

# 1 Enter the TAX #

DESCRIPTOR

TYPE

RATE (%) Shown only on TYPE=TAX %

P-MODE:TAX CONFIGURATION TAX 9 DESCRIPTOR XXXXXXXX 9=TAX No TAX TYPE (0=TAX %,1=TABLE1,2=TABLE2)

9

TAX RATE (%) 99.99ADD ON OR VAT (0=ADD ON,1=VAT) 9 *1MAXIMUM NON TAXABLE AMOUNT 99.99 *1

PRINT TAX Y *2 PRINT ZERO TAX Y *2

28 ◆ NEC RSenCounter 4000 Reference Manual 2350REF01

Page 37: NEC4000 Programming

P-MODEP-MODE MENU STRUCTURE

TAX TABLE PROGRAMMING [P3-2]

☞ [1][ENTER] or [ENTER]

TAX TABLE PROGRAMMING [P3-2-1]

Tax 1 [P3-1-1]: Programming fields and related flags.

Field Descriptor Default Explanation

TAX 9 Show selected Tax #

DESCRIPTOR

TAX TYPE 0

TAX RATE (%) 0.00 Skip on TAX TYPE=1,2

ADD ON OR VAT 0

MAXIMUM NON-TAXABLE

AMOUNT 0

PRINT TAX Y

PRINT ZERO TAX N

P-MODE:TAX TABLE# DESCRIPTOR1 ABCDEFGHIJKL TAX TABLE 12 ABCDEFGHIJKL TAX TABLE 2

Tax Table [P3-2]: Programming fields and explanations

Field Descriptor Default Explanation

# 1 Enter the TAX Table #

DESCRIPTOR

P-MODE:TAX TABLE 1 PROGRAMMING (1/2)9=TAX TABLE # 1 or 2 FIRST # 9999

SECOND # 99 MAX. NON-TAXABLE SALES AMOUNT 99.99 FIRST TAX 99.99 NON-REPEAT BREAK;

99 99 99 99 99 99 99 99 99 99 Cursor moves from left to right

99 99 99 99 99 99 99 99 99 9999 99 99 99 99 99 99 99 99 9999 99 99 99 99 99 99 99 99 9999 99 99 99 99 99 99 99 99 9999 99 99 99 99 99 99 99 99 9999 99 99 99 99 99 99 99 99 9999 99 99 99 99 99 99 99 99 99

99 99 99 99 99 99

2350REF01 NEC RSenCounter 4000 Reference Manual ◆ 29

Page 38: NEC4000 Programming

P-MODEP-MODE MENU STRUCTURE

TAX OPTION [P3-3]

P-MODE:TAX TABLE 9 PROGRAMMING (2/2) FIRST # 9999 SECOND # 99 MAX. NON-TAXABLE SALES AMOUNT 99.99 FIRST TAX 99.99 REPEAT BREAK;

99 99 99 99 99 99 99 99 99 9999 99 99 99 99 99 99 99 99 9999 99 99 99 99 99 99 99 99 9999 99 99 99 99 99 99 99 99 9999 99 99 99 99 99 99 99 99 9999 99 99 99 99 99 99 99 99 9999 99 99 99 99 99 99 99 99 9999 99 99 99 99 99 99 99 99 99

99 99 99 99 99 99

Tax Table [3-2-1]: Programming fields and related flags.

Field Descriptor Default Explanation

FIRST # 0000

SECOND # 00

MAX. NON-TAXABLE SALES AMOUNT

00.00 Sales amount under this will not be taxed.

FIRST TAX 00.00 Tax amount under this will not be collected.

NON-REPEAT BREAK: 00 86 fields provided.

REPEAT BREAK 00 86 fields provided.

P-MODE:TAX OPTION ROUND FACTOR (01,50,99) 99 01/50/99 NET PLU BY VAT N

Tax Option [P3-3]: Programming fields and related flags.

Field Descriptor Default Explanation

ROUND FACTOR 50

NET PLU VAT If Y, then subtract VAT amount from each PLU sales amount in PLU Report

30 ◆ NEC RSenCounter 4000 Reference Manual 2350REF01

Page 39: NEC4000 Programming

P-MODEP-MODE MENU STRUCTURE

SYSTEM OPTION [P4]

GLOBAL OPTION [P4-1]

● *1 0=disabled

● *2 It will ask “1. RETRY 2. BACK-UP 3. CANCEL PRINT” In taking Z, if ‘CANCEL PRINT’ is selected, then do not reset Z area.

● *3 Condiment KPG must be set to “0” to follow the main item in sorting to KP Items will be sorted after SEND DTO, TENDER, SERVICE, or STORE.

P-MODE :SYSTEM OPTION1 GLOBAL OPTION2 TRANSACTION OPTION3 TABLE SERVICE OPTION4 DRAWER & TENDER OPTION5 PRINT FORMAT AND OPTION6 CLOSING OPTION7 DISPLAY OPTION8 SCREEN CONFIGURATION

P-MODE:SYSTEM OPTION-GLOBAL OPTION CASHIER/SERVER(0=POP UP,1=STAY DOWN) 9 ENFORCE SECRET CSHR/SVR SIGN ON CODE N AUTO QUIT AFTER STORE/SVC./TENDER(SEC) 99 PRICE LEVEL (0=POP UP,1=STAY DOWN) 1 KEYBOARD LEVEL(0=POP UP,1=STAY DOWN) 1 CONSOLIDATION LIKE ITEMS Y SORT ITEMS TO R/K/D Y *3 PRINT AND DISPLAY ITEM QTY OF "1" Y AUTO STORE OPEN TRANS.(SEC) 999 *1 RUSH TIME 1 FOR ORDER (SEC) 999 *1 MGR. REQ. TO CANCEL PRINT N *2

2350REF01 NEC RSenCounter 4000 Reference Manual ◆ 31

Page 40: NEC4000 Programming

P-MODEP-MODE MENU STRUCTURE

Global Option [P4-1]: Programming fields and related flags.

Field Descriptor Default Explanation

CASHIER/SERVER 1

ENFORCE SECRET CSHR/SVR SIGN ON CODE

N If Y, then enforce [CSHR CODE] “SECRET CODE” [CSHR CODE]

X OUT CODES ENTERED ON DISPLAY

AUTO QUIT AFTER STORE/SVC./TENDER(SEC)

0 0=disabled

PRICE LEVEL 1

KEYBOARD LEVEL 1

CONSOLIDATION LIKE ITEMS Y Consolidated an item by one item delay method if this flag =Y.

SORT ITEMS TO R/K/D* No Item Sort to Tran. Log

Y Items are sorted by sort key set in PLU at Service/store/send to/tender

PRINT AND DISPLAYITEM QTY. OF “1”

Y

AUTO STORE OPEN TRANS. 0 Store an order after the programmed time. It will be brought up upon sign on by the corresponding cashier or server.

RUSH TIME 1 FOR ORDER 0 After the number of programmed seconds on an order, it will indicate on the order.

MGR. REQ. TO CANCEL PRINT N If =Y, then in printer error, require a MGR to abort print job.

• Default 0= Disabled

32 ◆ NEC RSenCounter 4000 Reference Manual 2350REF01

Page 41: NEC4000 Programming

P-MODEP-MODE MENU STRUCTURE

TRANSACTION OPTION [P4-2]P-MODE:SYSTEM OPTION-TRANSACTION OPTION ENFORCE :

SBTL KEY ENTRY YORDER DESTINATION YAT BEGINNING OF TRANSACTION Y# KEY ENTRY YTENT # ENTRY YNRGT CALCULATION BY STATION Y

ALLOW :ORDER DISC./SURCHARGE BEFORE SBTL YMODIFY DRIVE THRU ORDER Y[SERVE ORDER] TO BUMP KVS ORDER NVOIDS AFTER SUBTOTAL N

Transaction Option [P4-2]: Programming fields and related flags.

Field Descriptor Default Explanation

ENFORCE:

SBTL KEY ENTRY N If=Y, then SBTL key entry required before SERVICE, STORE, SEND, TEN-DER, ORDER DISC, SURCHARGE, or ROUND, however exceptions can be made in the ALLOW section below.

ORDER DESTINATION N

AT BEGINNING OF

TRANSACTION N

# KEY ENTRY N

TENT # ENTRY N

NRGT CALCULATION BY STATION Y If=Y, then Trans. Void Amount can not draw its station’s Gross Sales negative. If this flag is set to "N", then “DAILY GT” in the balancing section will not be a sum of absolute values. DAILY GT will repre-sent a sum of all accounts in this section.

ALLOW :

ORDER DISC./SURCHARGE BEFORE SBTL

Y ORDER DISC OR SURCHARGE is allowed without SBTL key.

MODIFY DRIVE THRU ORDER Y Drive Through order after sent can not be modified.

[SERVE ORDER] TO BUMP KVS ORDER

N

VOIDS AFTER SUBTOTAL N If=N, no voids are allowed after selection of subtotal.

2350REF01 NEC RSenCounter 4000 Reference Manual ◆ 33

Page 42: NEC4000 Programming

P-MODEP-MODE MENU STRUCTURE

TABLE SERVICE OPTION [P4-3]P-MODE:SYSTEM OPTION-TABLE SERVICE OPTION TRANSFER A GUEST CHECK AUTOMATICALLY N ENFORCE # GUESTS ENTRY ON GUEST CHECK N ALLOW MULT. TABLES WITH SAME TABLE # N DISPLAY ALL CHECKS WITH SAME TABLE # N CONSOLIDATE ITEMS AFTER SERVICE N

Table Service Option [P4-3]: Programming fields and related flags.

Field Descriptor Default Explanation

TRANSFER A GUEST CHECK AUTOMATICALLY

N Check will be transferred to a person who picks it up.

ENFORCE # GUESTS ENTRY ON GUEST CHECK

N If this flag says Y, then it will prompt you to enter GUEST # entry when a guest check is created.

ALLOW MULT. TABLES WITH SAME TABLE#

N Check can be opened under the same Table # however under a different check#

DISPLAY ALL CHECKS WITH SAME TABLE #

N When table # function key is used, dis-play will present all open checks with the same table number.

CONSOLIDATE ITEMS AFTER SERVICE

N

34 ◆ NEC RSenCounter 4000 Reference Manual 2350REF01

Page 43: NEC4000 Programming

P-MODEP-MODE MENU STRUCTURE

DRAWER AND TENDER OPTION [P4-4]

P-MODE:SYSTEM OPTION-DRAWER & TENDER OPTION CASH IN DRAWER AMOUNT LIMIT 9999999.99 OPEN DRAWER TIME LIMIT IN SEC 99 MGR REQUIRED FOR SALES OVER 9999999.99 DISABLE TRANS. IF DRAWER OPEN Y ENFORCE BEGIN CASH ENTRY 0 (0=AFTER FINAN'L Z1, 1=AFTER SHIFT Z1, 2=AFTER CSHR Z1, 3=NO COMPULSORY) ENFORCE AMOUNT TENDER Y ALLOW UNDER TENDER Y MGR CONTROL ON: NEGATIVE BALANCE SALES Y ZERO BALANCE SALES Y CHARGE TIP AUTO DEDUCT FROM CASH Y OPEN DRAWER ON ZERO BALANCE SALES Y OPEN DRAWER AFTER FINANCIAL REPORT 9 (0:X 1:Z 2:X or Z, 3:NO)

Drawer and Tender Option [P4-4]: Programming fields and related flags.

Field Descriptor Default Explanation

CASH IN DRAWER AMOUNT LIMIT 0.0

OPEN DRAWER TIME LIMIT IN SEC 0

MGR REQUIRED FOR SALES OVER 0.0 If over, then ‘MANAGER REQUIRED’ which can be over-ridden in X

DISABLE TRANS. IF DRAWER OPEN N

ENFORCE BEGIN CASH ENTRY NO COMPLUSORY

If Financial Z1, then prompt “Enter Begin Cash” to the first cashier signed on to Drawer A and B after Financial Z1 is taken for this Station.

ENFORCE AMOUNT TENDER Y

ALLOW UNDER TENDER N

MGR CONTROL ON:

NEGATIVE BALANCE SALES Y

ZERO BALANCE SALES N

CHARGE TIP AUTO DEDUCT FROM CASH

N

OPEN DRAWER ON ZERO BALANCE SALES

N

OPEN DRAWER AFTER FINANCIAL REPORT

2

2350REF01 NEC RSenCounter 4000 Reference Manual ◆ 35

Page 44: NEC4000 Programming

P-MODEP-MODE MENU STRUCTURE

PRINT FORMAT AND OPTION [P4-5]

RECEIPT OPTION [P4-5-1]

RECEIPT FORMAT [P4-5-2]

● *1 Available when PRINT ONLY SUM OF ALL TAXES=N

P-MODE :SYSTEM OPTION-PRINT OPTION & FORMAT1 RECEIPT OPTION2 RECEIPT FORMAT3 KITCHEN REQUISITION4 REPORT5 TRANSACTION LOG6 SYSTEM LOG7 KEY STROKE HISTORY8 CTS (CLOSED TRANS. SUMMARY)

1P-MODE:SYSTEM OPTION-RECEIPT OPTION2 PRINT RECEIPT Y3 ALLOW TO PRINT MULTIPLE RECEIPTS Y4 PRINT RECEIPT AFTER STORE Y5 PRINT RCPT. AFTER AUTO/CLERK INTERRUPT Y7 PRINT SPLIT RECEIPT N8

Receipt Option [P4-5-1]: Programming fields and related flags.

Field Descriptor Default Explanation

RECEIPT OPTION:

PRINT RECEIPT N If ‘N’= No automatic printing of receipt, still can be printed by RECEIPT ISSUE key

ALLOW TO PRINT MULTIPLE RECEIPT

Y

PRINT RECEIPT AFTER STORE Y

PRINT RCPT. AFTER AUTO/CLERK INTERRUPT

N

PRINT SPLIT RECEIPT N If=Y, then print a receipt in split payment, If =N, do not print receipt until final pay-ment is complete.

P-MODE:SYSTEM OPTION-RECEIPT FORMAT PRINT ORDER # Y PRINT ORDER # IN BOLD Y PRINT MERCHANDISE SUBTOTAL Y PRINT TRANSACTION # Y PRINT STATION # Y PRINT TIME Y PRINT EMPLOYEE # Y PRINT SVR/CASHIER'S NAME Y PRINT "T" FOR TAX AT THE END OF PLU Y PRINT ONLY SUM OF ALL TAXES Y PRINT TAX, IF VAT Y *1 PRINT TAXABLE MERCHANDISE CNT & TOTAL Y PRINT NON TXBL MERCHANDISE CNT & TOTAL Y

36 ◆ NEC RSenCounter 4000 Reference Manual 2350REF01

Page 45: NEC4000 Programming

P-MODEP-MODE MENU STRUCTURE

KITCHEN REQUISITION [P4-5-3]

● * 1 If there is any item directed to the printer, this printer will print out all the items that are directed to other Kitchen Printers too.

Receipt Format [P4-5-2]: Programming fields and related flags.

Field Descriptor Default Explanation

RECEIPT CONFIGURATION:

PRINT ORDER # Y

PRINT ORDER # IN BOLD Y

PRINT MERCHANDISE SUBTOTAL Y

PRINT TRANSACTION # Y

PRINT STATION # Y

PRINT TIME Y

PRINT EMPLOYEE # Y

PRINT SVR/CASHIER’S NAME Y

PRINT “T” FOR TAX AT THE END OF PLU

N

PRINT ONLY SUM OF ALL TAXES Y If Y, then print only TAX TOTAL, other-wise print both individual TAX 1-6 and TAX TOTAL

PRINT TAX, IF VAT N

PRINT TAXABLE MERCHANDISE CNT & TOTAL

N Tally the taxable item count and amount separately for printing.

PRINT NON TXBL MERCHANDISE CNT & TOTAL

N Same as above on non-taxable items.

P-MODE:SYSTEM OPTION-KITCHEN REQUISTION KP OPTION:

PRINT ALL KP GROUP ITEMS AT KP Y *1SEND ORDER TO KP AT INTERRUPT Y

KP FORMAT:

# OF KP LINE FEED 9PRINT IN DOUBLE HEIGHT YPRINT KP HEADER/FOOTER ON KP YPRINT SEPARATOR BY MAIN ITEM? YPRINT ITEMS BY SEAT # YPRINT TOTAL QTY YPRINT TOTAL AMOUNT YPRINT TOTAL TAX YPRINT PRICE ON OPEN ITEM YPRINT PRICE ON ITEMS YPRINT CASHIER NAME IN BOLD Y

2350REF01 NEC RSenCounter 4000 Reference Manual ◆ 37

Page 46: NEC4000 Programming

P-MODEP-MODE MENU STRUCTURE

Example

SalesPLU 01/02/04/05

At the printerPrinter # 1 prints out : PLU 01/02/04Printer # 2 prints out : NonePrinter # 4 prints out : PLU 01/02/04

KPG# to Printer #1 12 13 14 25 4

PLU# KPG#01 102 203 404 505 0

Kitchen Requisition [P4-5-3]: Programming fields and related flags.

Field Descriptor Default Explanation

KP OPTION:

PRINT ALL KP GROUP ITEMS AT KP N

SEND ORDER TO KP AT INTERRUPT N Send items to KP automatically at interrupt.

KP FORMAT:

# OF KP LINE FEED 6

PRINT IN DOUBLE HEIGHT N Print items in double height.

PRINT KP HEADER/FOOTER ON KP

PRINT SEPARATOR BY MAIN ITEM? N Programmable in KP SYSTEM DESCRIPTOR

PRINT ITEMS BY SEAT # N

PRINT TOTAL QTY N Count Main Item only

PRINT TAX TOTAL N

PRINT TOTAL AMOUNT N

PRINT PRICE ON OPEN ITEM Y If the item is open item, price information on the item will be transmitted to KP for a cook’s reference.

PRINT PRICE ON ITEMS N

PRINT CASHIER NAME IN BOLD Y

38 ◆ NEC RSenCounter 4000 Reference Manual 2350REF01

Page 47: NEC4000 Programming

P-MODEP-MODE MENU STRUCTURE

REPORT [P4-5-4]P-MODE:SYSTEM OPTION-REPORTINACTIVE TOTALS ON REPORTS: FINANCIAL AND CASHIER REPORT Y ITEM/PLU Y SUB/MAJOR/PRODUCT MIX GROUP Y TIME PERIOD Y COUPON Y TIME & ATTENDANCE Y OTHER REPORTS Y

NON RESET GT & GROSS TOTAL ON Z YNON RESET GT & GROSS TOTAL ON X YREPORT ORDERS AS #GUEST ON T.P. RPT. YPRINT TPMH INSTEAD OF SPMH YPRINT ONLY TOTAL ON P.M.G. REPORT YADD WT. TO COUNT TOTAL OF SALES RPT. NCUT CASHIER REPORT BY CASHIER YCUT STRING REPORT BY REPORTS NPRINT PLU # ON SALES REPORTS Y

Report [P4-5-4]: Programming fields and related flags.

Field Descriptor Default Explanation

INACTIVE TOTALS ON REPORTS:

FINANCIAL AND CASHIER

REPORT N

ITEM/PLU N

SUB/MAJOR/PRODUCT MIX

GROUP N

TIME PERIOD N

COUPON N

TIME & ATTENDANCE N

OTHER REPORTS N

NON RESET GT & GROSS TOTAL ON Z Y

NON RESET GT & GROSS TOTAL ON X N

REPORT ORDERS AS #GUEST ON T.P. RPT. N

PRINT TPMH INSTEAD OF SPMH N

PRINT ONLY TOTAL ON P.M.G. REPORT Y

ADD WT. TO COUNT TOTAL OF SALES RPT. N

CUT CASHIER REPORT BY CASHIER Y

CUT STRING REPORTS BY REPORT N

PRINT PLU # ON SALES REPORTS Y

2350REF01 NEC RSenCounter 4000 Reference Manual ◆ 39

Page 48: NEC4000 Programming

P-MODEP-MODE MENU STRUCTURE

TRANSACTION LOG [P4-5-5]P-MODE:SYSTEM OPTION-TRANSACTION LOG

ENABLE FIFO WHEN THE LOG AREA IS FULL NPRINT ONLY TRANSACTION WITH NEG. ITEM YPRINT STORE RECEIPT ON TRANS. LOG YPRINT SVC. WITH PRINT ON TRANS. LOG YPRINT SVC. NO PRINT TO TRANS. LOG Y

Transaction Log [P4-5-5]: Programming fields and related flags.

Field Descriptor Default Explanation

ENABLE FIFO WHEN THE LOG AREA IS FULL

N If =Y, then overwrite area in FIFO manner.If = N, then Suspend sales till Z is taken

PRINT ONLY TRANSACTION WITH NEG. ITEM

N Void, ERR-CORR. Negative PLU, Refund, CPN, Cancel, Trans. Void, Item Disc. Order Disc, Promo, Waste, Auto-Combo, PRICE O/R

PRINT STORE RECEIPT ON TRANS. LOG

N If Y, then log store receipt on STORE KEY

PRINT SVC. WITH PRINT ON TRANS. LOG

N If Y, then log information by SERVICE W/PRINT

PRINT SVC NO PRINT TO TRANS. LOG

N

40 ◆ NEC RSenCounter 4000 Reference Manual 2350REF01

Page 49: NEC4000 Programming

P-MODEP-MODE MENU STRUCTURE

SYSTEM LOG [P4-5-6]

● Preamble and post amble will not be printed on journal, however STORE ID# and Store descrip-tor will be printed.

● Journal will be printed in key sequence format.

P-MODE:SYSTEM OPTION-SYSTEM LOG ENABLE FIFO WHEN THE LOG AREA IS FULL N X REPORTS ON SYSTEM LOG Y Z REPORTS ON SYSTEM LOG Y PRINT EMPLOYEE FILE CHANGE Y PRINT EMPLOYEE PAY RATE CHANGE Y PRINT EMPLOYEE TIME CLOCK EDIT Y PRINT CLOCK IN/OUT DATA Y PRINT PAID OUT/RCVD ACCOUNT RECEIPT Y PRINT NO SALE ON SYSTEM LOG Y PRINT PLU PRICE CHANGE Y PRINT TIPS PAID OUT Y

System Log [P4-5-6]: Programming fields and related flags.

Field Descriptor Default Explanation

ENABLE FIFO WHEN THE LOG AREA IS FULL

N If =Y, then overwrite area in FIFO manner.If = N, then Suspend sales till Z is taken

X REPORTS ON SYSTEM LOG N

Z REPORTS ON SYSTEM LOG N

PRINT EMPLOYEE FILE CHANGE

Y

PRINT EMPLOYEE PAY RATE CHANGE

Y

PRINT EMPLOYEE TIME CLOCK EDIT

Y

PRINT CLOCK IN/OUT DATA Y

PRINT PAID OUT/RCVD ACCOUNT RECEIPT

Y

PRINT NO SALE ON SYSTEM LOG

Y

PRINT PLU PRICE CHANGE Y Print out the price change who, when, on what, old price, new price.

PRINT TIPS PAID OUT Y

2350REF01 NEC RSenCounter 4000 Reference Manual ◆ 41

Page 50: NEC4000 Programming

P-MODEP-MODE MENU STRUCTURE

KEY STROKE HISTORY [P4-5-7]

CTS (CLOSED TRANSACTION SUMMARY) [P4-5-8]

1P-MODE:SYSTEM OPTION-KEY STROKE HISTORY2 ENABLE FIFO WHEN ALLOC. AREA IS FULL Y3

Key Stroke History [P4-5-7]: Programming fields and related flags.

Field Descriptor Prog. Field or Selection Field by /

Field Lnx.

Data Type Default Explanation

ENABLE FIFO WHEN ALLOC. AREA IS FULL

Y/N 1 Flg. Y

1P-MODE:SYSTEM OPTION-CTS (CLOSED TRANS. SUMMARY) 2 ENABLE KEY HISTORY TRACKING Y3 ENABLE FIFO WHEN STATION CTS IS FULL Y

CTS [P4-5-8]: Programming fields and related flags.

Field DescriptorProg. Field

or Selection Field by /

Field Lnx.

Data Type Default Explanation

ENABLE KEY HISTORY TRACKING

Y/N 1 Flg. N

ENABLE FIFO WHEN STATIN CTS IS FULL

Y/N 1 Flg. N N = ’POLL CTS FROM SYS MASTER [129]’ message when remaining area <10 transactions.Y=No Message and overwrite the oldest transaction with the new transaction.

42 ◆ NEC RSenCounter 4000 Reference Manual 2350REF01

Page 51: NEC4000 Programming

P-MODEP-MODE MENU STRUCTURE

CLOSING OPTION [P4-6]

● If the common order number system is chosen, then reset to the starting number programmed after IRC Z1 financial. If a local number system is chosen, then reset it to the number that is formed by 2 digits of station number plus the last 3 digit of starting ORDER number after Z1 Financial.

P-MODE:SYSTEM OPTION-CLOSING OPTIONALLOW Z1 IF OPEN ORDERS NRESET; TRANSACTION # AFTER Z1 N ORDER # AFTER Z1 IF NO OPEN ORDERS Y ORDER # AFTER TRACK 3 Z1 Y DRAWER ASSIGN AFTER Z1 CASHIER YUPDATE COUNTERS IF ZERO SALE TOTAL NCASH DECLARE REQUIRED BEFORE REPORTS NENABLE FIFO WHEN TK CLOCK DATA IS FULL N

Closing Option [P4-6]: Programming fields and related flags.

Field Descriptor Default Explanation

ALLOW Z1 IF OPEN ORDERS N

RESET;

TRANSACTION # AFTER Z1 N *Z1 Financial

ORDER # AFTER Z1 IF NO OPEN ORDERS

Y *Z1 Financial

COMMON ORDER # AFTER TRACK 3 Z1

Y * This flag is good only at Sys Master

DRAWER ASSIGN AFTER Z1 CASHIER

Y

UPDATE COUNTERS IF ZERO SALE TOTAL

N

CASH DECLARE REQUIRED BEFORE REPORTS

N *X1 & Z1 FIN. CASHIER, DRAWER STATION (X1 ONLY)Open drawer too. Declare is good till moved to another Mode.

ENABLE FIFO WHEN TK CLOCK DATA IS FULL

N When allocated buffer gets full, its buff-ering acts as FIFO manner.If=N, then stop TK operation is sus-pended till Period End is done.

2350REF01 NEC RSenCounter 4000 Reference Manual ◆ 43

Page 52: NEC4000 Programming

P-MODEP-MODE MENU STRUCTURE

DISPLAY OPTION [P4-7]

SCREEN CONFIGURATION [P4-8]

ORDER/CHECK INFORMATION LINE (Line 1) [P4-8-1]

P-MODE:SYSTEM OPTION-DISPLAY OPTION DISPLAY PRICE OF LINE ITEMS Y INSERT SVC TIME & SVR NAME N INSERT PAYMENT INFORMATION N

Display Option [P4-7]: Programming fields and related flags.

Field Descriptor Default Explanation

DISPLAY PRICE OF LINE ITEMS Y

INSERT SVC TIME & SVR NAME N

INSERT PAYMENT INFORMATION N

P-MODE :SYSTEM OPTION-SCREEN CONFIGURATION1 ORDER/CHECK INFORMATION LINE2 ITEM LINE3 ACTIN LINE4 SERVICE INFORMATION LINE5 STATUS LINE6 TENDER INFORMATION

P-MODE:SYSTEM OPTION-ORDER/CHECK INFORMATION LINE BACK COLOR (0-15) 99 ORDER # COLOR (0-15) 99 TABLE # COLOR (0-15) 99 GUEST # COLOR (0-15) 99 ORDER ELAPSE TIMER COLOR 1 (0-15) 99 BACK COLOR OF TIMER AFTER RUSH TIME 1 99

(0-15)(0-15)

Order/Check Information [P4-8-1]: Programming fields and related flags.

Field Descriptor Default Explanation

BACK COLOR 15

ORDER # COLOR 0 Define a color of text

TABLE # COLOR 0 Define a color of text

GUEST # COLOR 0 Define a color of text

ORDER ELAPSE TIMER COLOR 1

0 Define a color of text

BACKGROUND COLOR OF TIMER AFTER RUSH TIME 1

0 Define the timer’s background color

44 ◆ NEC RSenCounter 4000 Reference Manual 2350REF01

Page 53: NEC4000 Programming

P-MODEP-MODE MENU STRUCTURE

ITEM LINE (Line 2-17) [P4-8-2]

ACTION LINE (Line 19) [P4-8-3]

P-MODE:SYSTEM OPTION-ITEM LINE BACK COLOR (0-15) 99 CURSOR COLOR (0-15) 99 SEAT # COLOR (0-15) 99 SEAT # BACK COLOR (0-15) 99 PRICE COLOR (0-15) 99 PRICE BACK COLOR (0-15) 99 MARKED ITEM TEXT COLOR (0-15) 99 MARKED ITEM BACK COLOR (0-15) 99

Item Line (Line 2-17) [P4-8-2]: Programming fields and related flags.

Field Descriptor Default Explanation

BACK COLOR 2

CURSOR COLOR 8 Define a color of text

SEAT # COLOR 0

SEAT # BACK COLOR 15

PRICE COLOR 15

PRICE BACK COLOR 0

MARKED ITEM TEXT COLOR 0

MARKED ITEM BACK COLOR 15

P-MODE:SYSTEM OPTION-ACTION LINE BACK COLOR (0-15) 99 ACTION LINE TEXT COLOR (0-15) 99

Action Line (Line 19) [P4-8-3]: Programming fields and related flags.

Field Descriptor Default Explanation

BACK COLOR 4

ACTION LINE TEXT COLOR 15 Define a color of text

2350REF01 NEC RSenCounter 4000 Reference Manual ◆ 45

Page 54: NEC4000 Programming

P-MODEP-MODE MENU STRUCTURE

SERVICE INFORMATION LINE [P4-8-4]

STATUS LINE [P4-8-5]

TENDER INFORMATION (Line 17) [P4-8-6]

P-MODE:SERVICE INFORMATION LINE BACK COLOR (0-15) 99 TEXT COLOR (0-15) 99

Service Information Line: [P4-8-4] Programming fields and related flags.

Field Descriptor Default Explanation

BACK COLOR 15

TEXT COLOR 0 Define a color of text

P-MODE:STATUS LINE BACK COLOR (0-15) 99 0-15 STATUS LINE TEXT COLOR (0-15) 99 0-15

P-Mode Status Line [P4-8-5]: Programming fields and related flags.

Field Descriptor Default Explanation

BACK COLOR 15

STATUS LINE TEXT COLOR 0 Define a color of text

P-MODE:TENDER INFORMATION TAX (0-15) 99 TOTAL (0-15) 99 TENDER MEDIA (0-15) 99 CHANGE (0-15) 99 AMT DUE (0-15) 99 PBAL (0-15) 99

Tender Information (Line 17) [P4-8-6]: Programming fields and related flags.

Field Descriptor Default Explanation

TAX 15

TOTAL 15

TENDER MEDIA 15

CHANGE 15

AMT DUE 15

PBAL 15

46 ◆ NEC RSenCounter 4000 Reference Manual 2350REF01

Page 55: NEC4000 Programming

P-MODEP-MODE MENU STRUCTURE

PLU PROGRAMMING [P5]

PLU [P5-1]

● Item 7 & 8 will not be allowed to be accessed if memory is not allocated.

CREATE OR EDIT PLU [P5-1-1]

☞ [CURSOR UP/DOWN][ENTER] or PLU # and [ENTER]

P-MODE :PLU1 PLU2 PLU PROPERTY3 PLU SHIFT4 PLU PRICE EDIT5 PLU PRICE TABLE6 PLU PRICE LEVEL SCHEDULER7 CONDIMENT TABLE8 CONDIMENT CHAIN9 LINKED PLU TABLE10 DISCOUNT CATEGORY11 PRINT PLU BY TBL, PRICE LIST, PRICE SCHEDULER12 DOWNLOAD

P-MODE :PLU1 CREATE OR EDIT PLU2 CREATE PLU BY RANGE3 DELETE PLU4 DELETE PLU BY RANGE5 PLU ACCESS FROM KEYBOARD6 PLU ACCESS FROM PLU LIST7 EDIT OPTIONAL PLU RECEIPT DESCRIPTOR8 EDIT KP/KVS DESCRIPTOR9 MENU KEY RELOCATION

P-MODE:CREATE OR EDIT PLU PLU # DESCRIPTOR PLU PPTY # 12345678901234 ABCDEFGHIJKLMNOP 9999

Create or Edit PLU: [P5-1-1] Programming fields and related flags.

Field Descriptor Default Explanation

# PLU #

DESCRIPTOR PLU 1

PLU PPTY # Shows PLU PPTY # to which this PLU belongs.

2350REF01 NEC RSenCounter 4000 Reference Manual ◆ 47

Page 56: NEC4000 Programming

P-MODEP-MODE MENU STRUCTURE

CREATE OR EDIT PLU [P5-1-1-1]

● *1 If PRICE TYPE=PRC.TBL, then this PRICE/TBL# field will hold 3 digit price table # and display its descriptor after it.

● *2 Default is 0, however if this is not changed other than 0 upon exit with PLU #, then “Enter PLU PPTY. #”

● *3 RECEIPT DESCR. # will show the pertinent receipt descriptor.

● *4 Last 4 characters after "^" are to let a programmer know those are not displayed in QS.

● *5 If COND. FNC KEY is allowed, then CONDIMENT function key will present CONDIMENET Chain or TABLE linked to this PLU, however this will not force a selection from the table and allow to exit at any time with [EXIT].

● *6 If PLU is used with PLU Shift, this PLU only used its PLU3 to reach the Target PLU. Example: PLU# 3000=Coke Shift PLU # 10000= Small -> Target PLU# = 13000 Small Coke

● *7 A Condiment in the Condiment Table will not call TLU, Linked PLU, MLU Tables. It may call another condiment table or chain, however it will not hold the control of the previous Condiment Table.

P-MODE:CREATE OR EDIT PLU (1/2) PLU # 99999999999999 DESCRIPTOR (12th.=^) XXXXXXXXXXXXXXXX *4,*6 ACTIVE Y TEXT COLOR (0-15) 99 PLU TYPE (0=NORMAL,1=CONDIMENT) 9 *2 PLU PPTY # 9999 0-(Memory Allocation) PRICE (0=PRESET,1=HALO,2=PRICE TBL) 9 PRICE/HALO 999999.99 Skip on PRICE

TYPE=2 PRICE TBL # 999 Skip on PRICE

TYPE=0,1 -PLU PRICE Y COST 999999.99

LINKED TBL (0=COND.TBL, 1=COND.CHAIN, 2=PLU TBL, 3=TLU, 4=MLU)

9

LINKED TBL # 999 *7 ALLOW [CONDIMENT] FUNCTION KEY Y Skip on LINKED

TBL=1,2,3,4 *5 MLU # 999 999

P-MODE:CREATE OR EDIT PLU (2/2) PLU # 99999999999999 DESCRIPTOR XXXXXXXXXXXXXXXX RECEIPT DESCR.#999 XXXXXXXXXXXXXXXXXXXXX

48 ◆ NEC RSenCounter 4000 Reference Manual 2350REF01

Page 57: NEC4000 Programming

P-MODEP-MODE MENU STRUCTURE

Create or Edit PLU (P5-1-1-1): Programming fields and related flags.

Field Descriptor Default Explanation

PLU#

DESCRIPTOR No title for this field.

ACTIVE Y If=N, then this PLU can not be sold.

TEXT COLOR (Black) 15

PLU TYPE 0 Normal

PLU PPTY # 1 Points to PLU Property that this PLU belongs to.

PRICE 0 (PRESET) HALO=OPEN HIGH AMOUNT LOCK OUT

PRICE/HALO 0.00 SKIP ON PRICE=2

PRICE TBL # 0 SKIP ON PRICE=0,1

-PLU PRICE N

COST 0.00

LINKED TBL 0 IF LINKED COND. TYPE-TABLE, dis-play condiment table name after this.

LINKED TBL # Holds number for one of above tables.

ALLOW [CONDIMENT] FUNCTION KEY

N Skip on LINKED TBL=1,2,3,4Å@

MLU# 1 0

MLU# 2 0

RECEIPT DESCRIPTOR # 0 Points to 24 Character Receipt Descriptor record number and displays its descriptor.

2350REF01 NEC RSenCounter 4000 Reference Manual ◆ 49

Page 58: NEC4000 Programming

P-MODEP-MODE MENU STRUCTURE

CREATE PLU BY RANGE [P5-1-2]

● Note: Copy everything but descriptor, price, and cost.

DELETE PLU [P5-1-3]

☞ [CURSOR UP/DOWN][ENTER] or PLU # and [ENTER]

P-MODE:CREATE PLU BY RANGE COPY # 12345678901234 ABCDEFGHIJKLMNOP TO # 12345678901234 - # 12345678901234CREATE PLUs EVERY 999 ARE YOU SURE TO PROCEED? Y

=== ORIGNAL PLU INFORMATION === Following information is Display only PLU # 99999999999999

DESCRIPTOR XXXXXXXXXXXXXXXX

ACTIVE Y TEXT COLOR (0-15) 99 PLU TYPE (0=NORMAL,1=CON-DIMENT)

9

PLU PPTY # 9999 PRICE (0=PRE-SET,1=HALO,2=PRICE TBL)

9

PRICE/HALO 999999.99PRICE TBL # 999-PLU PRICE Y COST 999999.99

Create PLU By Range [P5-1-2]: Programming fields and related flags.

Field Descriptor Default Explanation

COPY # 0 Original PLU

TO # 0 From this PLU# to –PLU# will have the same contents as ORIGINAL PLU except PLU DESCRIPTOR.

– # 0

CREATE PLUs EVERY 0 Original PLU will be copied every xxx starting from COPY TO PLU#

ARE YOU SURE TO PROCEED? N

P-MODE:DELETE PLU PLU # DESCRIPTOR PLU PPTY # 12345678901234 ABCDEFGHIJKLMNOP 9999

Delete PLU [P5-1-3]: Programming fields and related flags.

Field Descriptor Default Explanation

# 0 PLU # TO BE DELETED

DESCRIPTOR

PLU PPTY # 0

50 ◆ NEC RSenCounter 4000 Reference Manual 2350REF01

Page 59: NEC4000 Programming

P-MODEP-MODE MENU STRUCTURE

Delete PLU [P5-1-3-1]

● ‘DELETE PLU INFORMATION’ will be displayed after ‘DELETE PLU#’ is entered.

P-MODE:DELETE PLU

ARE YOU SURE TO DELETE THIS PLU? Y

=== INFORMATION TO BE DELETED === Following informa-tion is Display only

PLU # 99999999999999 DESCRIPTOR XXXXXXXXXXXXXXXXACTIVE Y TEXT COLOR (0-15) 99 PLU TYPE (0=NORMAL,1=CONDIMENT) 9 PLU PPTY # 9999 PRICE (0=PRESET,1=HALO,2=PRICE TBL) 9 PRICE/HALO 999999.99 PRICE TBL # 999 -PLU PRICE Y COST 999999.99

Delete PLU [P5-1-3-1]: Programming fields and related flags.

Field Descriptor Default Explanation

ARE YOU SURE TO DELETE THIS PLU?

N

=== INFORMATION TO BE DELETED ===

*** Refer to the above list ***

2350REF01 NEC RSenCounter 4000 Reference Manual ◆ 51

Page 60: NEC4000 Programming

P-MODEP-MODE MENU STRUCTURE

DELETE PLU BY RANGE [P5-1-4]

PLU ACCESS FROM KEYBOARD [P5-1-5]

● Corresponding keyboard level’s function key descriptor.Reflect this keyboard level on Line 20 Status Line.

☞ [1][Enter]

● Pertinent PLU record is accessed and shown as below

● If the key pressed is anything other than the PLU key, then “Not MENU Key [099]” error isdisplayed.

P-MODE:DELETE PLU BY RANGEFROM # 0TO # 0

ARE YOU SURE TO PROCEED? N

=== INFORMATION TO BE DELETED === PLU # DESCRIPTORACTIVE TEXT COLOR (0-15) PLU TYPE (0=NORMAL,1=CONDIMENT) PLU PPTY # PRICE (0=PRESET,1=HALO,2=PRICE TBL) PRICE/HALO PRICE TBL # -PLU PRICE COST 999999

Delete PLU By Range [P5-1-4]: Programming fields and related flags.

Field Descriptor Default Explanation

FROM # 0

TO # 0

ARE YOU SURE TO PROCEED N

P-MODE:PLU ACCESS FROM KEYBOARD# DESCRIPTOR INTERNAL NAME1 KEY LVL1 KEY LVL12 KEY LVL2 KEY LVL23 KEY LVL3 KEY LVL34 KEY LVL4 KEY LVL45 KEY LVL5 KEY LVL5

P-MODE:PLU ACCESS FROM KEYBOARD KB LEVEL 1 BREAKFAST

PRESS THE KEY TO BE PROGRAMMED

52 ◆ NEC RSenCounter 4000 Reference Manual 2350REF01

Page 61: NEC4000 Programming

P-MODEP-MODE MENU STRUCTURE

☞ Display CREATE OR EDIT PLU [P5-1-1-1] on page 48.☞ [EXIT] will take you back to DELETE PLU BY RANGE [P5-1-4] on page 52.

PLU ACCESS FROM PLU LIST [P5-1-6]

● PLU PPTY # is sorted in ascending order.

☞ [1][Enter]

PLU ACCESS FROM PLU LIST [P5-1-6-1]

● [EXIT] will bring you back to the previous screen.

● PLU # is sorted in ascending order.

PLU Access From Keyboard [P5-1-5]: Programming fields and related flags.

Field Descriptor Default Explanation

# LEVEL 1

DESCRIPTOR DISPLAY CORRESPONDING KEY-BOARD LEVEL FUNCTION KEY DESCRIPTOR

P-MODE:PLU ACCESS FROM PLU LIST PPTY # DESCRIPTOR 9999 ABCDEFGHIJKL

PLU Access From PLU List [P5-1-6]: Programming fields and related flags.

Field Descriptor Default Explanation

PPTY # 0 0=All

DESCRIPTOR Corresponding PPTY’s descriptor

PLU# First PLU

1P-MODE:PLU ACCESS FROM PLU LIST2 PLU # DESCRIPTOR PRICE3 12345678901234 ABCDEFGHIJKLMNOP 999999.99

PLU Access From PLU List (P5-1-6-1) Programming fields and related flags.

Field Descriptor Default Explanation

PLU #

DESCRIPTOR Corresponding PLU’s descriptor

2350REF01 NEC RSenCounter 4000 Reference Manual ◆ 53

Page 62: NEC4000 Programming

P-MODEP-MODE MENU STRUCTURE

EDIT OPTIONAL PLU RECEIPT DESCRIPTOR [P5-1-7]

EDIT OPTIONAL PLU RECEIPT DESCRIPTOR [P5-1-7-1]

EDIT KP/KVS DESCRIPTOR [P5-1-8]

P-MODE:EDIT OPTIONAL PLU RECEIPT DESCRIPTOR# DESCRIPTOR999 ABCDEFGHIJKLMNOPQRSTUVWX

Edit Optional PLU Receipt Descriptor [P5-1-7]: Programming fields and related flags.

Field Descriptor Default Explanation

#

DESCRIPTOR

P-MODE:EDIT OPTIONAL PLU RECEIPT DESCRIPTORRECEIPT DESCRIPTOR # 001DESCRIPTOR XXXXXXXXXXXXXXXXXXXXXXXX

Edit Optional PLU Receipt Descriptor [P5-1-7-1]: Programming fields and related flags.

Field Descriptor Default Explanation

#

DESCRIPTOR Optional PLU Receipt descriptor (24 characters)

1P-MODE:EDIT KP/KVS DESCRIPTOR2 # DESCRIPTOR3 999 ABCDEFGHIJKL

Edit KP/KVS Descriptor [P5-1-8]: Programming fields and related flags.

Field DescriptorProg. Field or

Selection Field by /

Field Lnx.

Data Type Default Explanation

# 1-M.A. Max 999 3 Int.

DESCRIPTOR 12 Chr.

54 ◆ NEC RSenCounter 4000 Reference Manual 2350REF01

Page 63: NEC4000 Programming

P-MODEP-MODE MENU STRUCTURE

EDIT KP/KVS DESCRIPTOR [P5-1-8-1]

MENU KEY RELOCATION [P5-1-9]

● Corresponding keyboard level’s function key descriptor.Reflect this keyboard level on Line 20 Status Line.

☞ [1][Enter]

1P-MODE:EDIT KP/KVS DESCRIPTOR2 KP/KVS DESCRIPTOR # 0013 DESCRIPTOR XXXXXXXXXXXX45

Edit KP/KVS Descriptor [P5-1-8-1]: Programming fields and related flags.

Field DescriptorProg. Field or

Selection Field by /

Field Lnx.

Data Type Default Explanation

# 1-M.A. Max 999 3 Int. 0

DESCRIPTOR 12 Chr. KP/KVS descriptor

1P-MODE:MENU KEY RELOCATION 2 # DESCRIPTOR INTERNAL NAME3 9 ABCDEFGHIJKL KEY BRD LVL X

Menu Key Relocation [P-5-1-9]: Programming fields and related flags.

Field Descriptor Explanation

# Select Keyboard level

DESCRIPTOR

INTERNAL NAME

P-MODE :MENU KEY RELOCATION# DESCRIPTOR INTERNAL NAME1 BREAKFAST KEY BRD LVL 12 LUNCH KEY BRD LVL 23 DINNER KEY BRD LVL 34 SUN. BRUNCH KEY BRD LVL 45 MANAGER KEY BRD LVL 5

2350REF01 NEC RSenCounter 4000 Reference Manual ◆ 55

Page 64: NEC4000 Programming

P-MODEP-MODE MENU STRUCTURE

MENU KEY RELOCATION - Keyboard level 1 [P5-1-9-1]

● Note : Error “Invalid Selection”, if any key other than PLU is pressed.

☞ [Loc. 1]

Key Location 1 [P5-1-9-1-1]

● Note 1:

1P-MODE:MENU KEY RELOCATION 2 KB LEVEL 1 BREAKFAST34 PRESS THE KEY TO BE PROGRAMMED56 7 890

1P-MODE:MENU KEY RELOCATION–KB LEVEL 1 BREAKFASTABC Display Level & Descriptor2 CURRENT:CHEESE BURGEREXT 12345678901234 Display current information 34 NEW ASSIGNMENT: KEY LOC. 0015 KEY TYPE (0=EXIT, 1=PLU) 16 CODE # xxxxxxxxxxxxxxxx 12345678901234 *1 xxx..DESCRIPTOR78 CODE # DESCRIPTOR9 00000000000001 TOMATO0 00000000000002 LETTUCE1 00000000000004 PICKLES2 00000000000005 MAYO3 12345678901233 HAMBURGER4 12345678901234 CHEESE BURGER5 12345678901235 HOT DOG6 12345678901236 GRILLED CHICKEN7 12345678901237 ROAST BEEF8 12345678901238 CHICKEN SANDWICH

1. Default value

2. The initial cursor location within the screen, EDIT KP/KVS DESCRIPTOR [P5-1-8-1] on page 55, is in the Key Type field.

3. [PG-UP/PG-DWN] scrolls PLU List

3-1) Enter PLU number in CODE# field.

3-2) [EXIT] will;

3-2-1) Check the validity of Code # (see Note 2), if it is valid, then

3-2-2) Assign the Code# to the key

3-2-3) and bring you back to EDIT KP/KVS DESCRIPTOR [P5-1-8-1] on page 55.

3-3) KEY TYPE; 0=EXIT displays the screen, EDIT KP/KVS DESCRIPTOR [P5-1-8] on page 54.

3-4) [C-UP/C-DWN] are used to step through KEY TYPE and CODE # fields.

Field Name Default ValueKey Type 1Code # Key Code of the pressed key

56 ◆ NEC RSenCounter 4000 Reference Manual 2350REF01

Page 65: NEC4000 Programming

P-MODEP-MODE MENU STRUCTURE

☞ [EXIT]☞ [P5-1-8-1-1-EXIT]

Menu Key Relocation [P5-1-8-1-1]

● Note 2: Check with Authority Level prior to the following process

If PLU NO. is not found (= not registered), then prompt:

The cursor will go to the screen, Menu Key Relocation [P5-1-8-1-1] on page 57, CODE number field (blank field).

Create a new INACTIVE PLU by this number and go to the screen, Menu Key Relocation [P5-1-8-1-1] on page 57, CODE number field.

Key Location 1 [P5-1-9-1-1]: Programming fields and related flags.

Field Descriptor Explanation

KB LEVEL

(DESCRIPTOR) Display KB Level Descriptor

CURRENT: Current Key Descriptor

(CODE #) Current Key Code number

NEW ASSIGNMENT:KEY LOC. Physical Key Location pressed (Vertically counted from upper left.

KEY TYPE

CODE # Key Code #

1P-MODE:MENU KEY RELOCATION 2 KB LEVEL 1 BREAKFAST34 PRESS THE KEY TO BE PROGRAMMED567 PREVIOUS KEY ASSIGNMENT: 8 LOC. 0019 KEY TYPE PLU0 CODE # 123456789012341 DESCRIPTOR CHEESE BURGEREXT2

PLU # 99999999999999 NOT FOUND

SELECT 1 TRY ANOTHER PLU # 2 CREATE NEW PLU BY THIS PLU #

LINE 6 CODE # 0

LINE 6 CODE # NEW PLU 12345678901234

2350REF01 NEC RSenCounter 4000 Reference Manual ◆ 57

Page 66: NEC4000 Programming

P-MODEP-MODE MENU STRUCTURE

PLU PROPERTY [P-5-2]

PLU [P5-2-1]

P-MODE:PLU PROPERTY# DESCRIPTOR REP.TYPE SORT # 9999 ABCDEFGHIJKL XXXXXXXX 99

PLU Property [P5-2]: Programming fields and related flags.

Field Descriptor Default Explanation

# PLU Property number

DESCRIPTOR PLU PPTY 1

REP. TYPE

SORT # 1

P-MODE:PLU PROPERTY (1/3)PLU PPTY # 9999 1-(Memory Allocation)

DESCRIPTOR XXXXXXXXXXXXREPORT TYPE (0=NORMAL,1=NON ADD 9 2=MEMO, 3=NON PROD)NON PROD SALES # (1-3) 9TAX 123456 Y Y Y Y Y YOUTPUT TO R/J/K/D Y Y Y YINDENTED YSORT KEY # 99COMPUL. SHIFT TYPE 123 Y Y YCONDIMENT QTY TO R/J/K/D Y

GROUPS:PROD MIX GRP 1 # 99 PIECE COUNT # 99PROD MIX GRP 2 # 99 PIECE COUNT # 99SUB GRP # 999

P-MODE:PLU PROPERTY (2/3)PLU PPTY # 9999 DESCRIPTOR XXXXXXXXXXXX

OPTION FLAGS: DISCOUNTABLE Y DISC CATEGORY # (0-99) 99 99

KITCHEN: KPG # (0-30) 99 KVG # 99 KV. COLOR # (0-7) 9

6 AUTO GRILL Y7 KGG# (0-30) 99

58 ◆ NEC RSenCounter 4000 Reference Manual 2350REF01

Page 67: NEC4000 Programming

P-MODEP-MODE MENU STRUCTURE

P-MODE:PLU PROPERTY (3/3)PLU PPTY # 9999 DESCRIPTOR XXXXXXXXXXXX

PRINT: RED Y REVERSE Y COND. PRICE ROLLED IN MAIN ITEM Y

INVENTORY: SP. ITEM STOCK Y -INV. ITEM Y

SCALE SCALE PLU N TARE WIEGHT TABLE 0

PLU Property [P5-2-1] Programming fields and related flags.

Field Descriptor Default Explanation

PLU PPTY # Hold number of this PLU Property

DESCRIPTOR PLU PPTY 1 Default descriptor is only on Rec. 1

REPORT TYPE 0

NON PROD SALES # 1 Only when REPORT TYPE is NON ADD.

TAX 123456 NNNNNN

OUTPUT TO R/J/K/D YYYY

INDENTED N

SORT KEY # 1 This key will be used for sort printing and displaying.

COMPUL. SHIFT TYPE 123 NNN

CONDIMENT QTY TO R/J/K/D Y If N, do not show/print quantity of this condiment

GROUPS:

PROD MIX GRP 1 # 0

PIECE COUNT # 0

PROD. MIX GRP 2 # 0

PIECE COUNT # 0

SUB GRP # 1

OPTION FLAGS:

DISCOUNTABLE N

DISC CATEGORY # # 0

2350REF01 NEC RSenCounter 4000 Reference Manual ◆ 59

Page 68: NEC4000 Programming

P-MODEP-MODE MENU STRUCTURE

PLU SHIFT [P5-3]Allocatable to max 200 PLU SHIFTS.

KITCHEN:

KPG # 0

KVG # 0

KV COLOR 0

REPEATABLE N

HOLD FIRE N

AUTO GRILL N

KGG 0

PRINT:

RED N

REVERSE N

COND. PRICE ROLLED IN MAIN ITEM

N

INVENTORY:

SP. ITEM STOCK N Special Item stock

-INV. ITEM N

SCALE

SCALE PLU N

TARE SEIGHT TABLE # 0

P-MODE:PLU SHIFT# DESCRIPTOR VALUE SHIFT TYPE999 ABCDEFGHIJKL 123456 8 9=1-(MEM. ALLOC.=200),

8=1-3

PLU Shift [P5-3]: Programming fields and related flags.

Field Descriptor Default Explanation

#

DESCRIPTOR PLU SHIFT DESCRIPTOR

VALUE 000000 SHIFT VALUE

SHIFT TYPE 1

PLU Property [P5-2-1] Programming fields and related flags.

Field Descriptor Default Explanation

60 ◆ NEC RSenCounter 4000 Reference Manual 2350REF01

Page 69: NEC4000 Programming

P-MODEP-MODE MENU STRUCTURE

PLU SHIFT [P5-3-1]

PLU PRICE EDIT [P5-4]

● Select PLU PPTY first

☞ [1][Enter]

P-MODE:PLU SHIFT PLU SHIFT # 999 DESCRIPTOR XXXXXXXXXXXX SHIFT VALUE 999999 SHIFT TYPE (1-3) 9 TEXT COLOR (0-15) 99

PLU Shift [P5-3-1]: Programming fields and related flags.

Field Descriptor Default Explanation

PLU SHIFT #

DESCRIPTOR MODIFIER 1 Default is only on Rec. 1

SHIFT VALUE 000000 This VALUE will be used to create the target PLU.

SHIFT TYPE 1

TEXT COLOR 15

P-MODE:PLU PRICE EDIT/PLU PPTY SELECTION 1/2 PPTY # DESCRIPTOR 9999 ABCDEFGHIJKL

PLU Price Edit [P5-4]: Programming fields and related flags.

Field Descriptor Default Explanation

PPTY #

DESCRIPTOR

2350REF01 NEC RSenCounter 4000 Reference Manual ◆ 61

Page 70: NEC4000 Programming

P-MODEP-MODE MENU STRUCTURE

PRICE EDIT [P5-4-1]

● All the PLUs belonging to PLU PPTY 1 will be listed here.

PLU Price Edit [P5-4-1-1]

● This will print out changes to the receipt printer or SYSTEM LOG by option.

● Change information should include before and after change with by whom, date, time, station, transaction number.

PLU PRICE TABLE [P5-5]

P-MODE:PLU PRICE EDIT 2/2PLU # DESCRIPTOR PRICE

12345678901234 ABCDEFGHIJKLMNOP 999999.99

PLU Price Edit [P5-4-1]: Programming fields and related flags.

Field Descriptor Default Explanation

PLU #

DESCRIPTOR

PRICE Current price Display only

P-MODE:PLU PRICE EDIT PLU # 99999999999999 DESCRIPTOR XXXXXXXXXXXXXXXX CURRENT PRICE 999999.99 NEW PRICE 999999.99

PLU Price Edit [P5-4-1-1]: Programming fields and related flags.

Field Descriptor Default Explanation

PLU #

DESCRIPTOR

CURRENT PRICE Current price Display only

NEW PRICE 0

P-MODE:PLU PRICE TABLE# DESCRIPTOR999 ABCDEFGHIJKL

62 ◆ NEC RSenCounter 4000 Reference Manual 2350REF01

Page 71: NEC4000 Programming

P-MODEP-MODE MENU STRUCTURE

PRICE TABLE [P5-5-1]

PLU PRICE LEVEL SCHEDULER [P5-6]

● If there are multiple effective periods applicable, then the earliest price level is selected. (If there is an applicable period with the date not allowed, then this will default to the default level set in X Mode. Programming over midnight is allowed.

● PRICE LEVEL FUNCTION KEY will override above price schedule.

P-MODE:PLU PRICE TABLE TABLE # 999 1-(Memory Allocation) DESCRIPTOR XXXXXXXXXXXX

PRICE LEVEL 1 XXX999999.99 XXX= Currency Mark PRICE LEVEL 2 XXX999999.99 PRICE LEVEL 3 XXX999999.99 PRICE LEVEL 4 XXX999999.99 PRICE LEVEL 5 XXX999999.99 PRICE LEVEL 6 XXX999999.99 PRICE LEVEL 7 XXX999999.99 PRICE LEVEL 8 XXX999999.99

PLU Price Table [P5-5]: Programming fields and related flags.

Field Descriptor Default Explanation

# Current table num-ber called

DESCRIPTOR “PRICE TBL 1” on the 1st. Rec.

Enter descriptor for this table number.

PLU Price Table [P5-5-1]: Programming fields and related flags.

Field Descriptor Default Explanation

TABLE # Current table num-ber called

If you enter the new table number, then call the new Table by its number.

DESCRIPTOR “PRICE TBL 1” on the 1st. Rec.

Enter descriptor for this table number.

PRICE LEVEL 1-8 0.0

P-MODE:PLU PRICE LEVEL SCHEDULER CURRENT DEFAULT LEVEL IN X-MODE 9 PRICE EFFECTIVE:

LEVEL PERIOD SUN MON TUE WED THU FRI SAT 1 HH:MM-HH:MM Y Y Y Y Y Y Y 2 HH:MM-HH:MM Y Y Y Y Y Y Y 3 HH:MM-HH:MM Y Y Y Y Y Y Y 4 HH:MM-HH:MM Y Y Y Y Y Y Y 5 HH:MM-HH:MM Y Y Y Y Y Y Y 6 HH:MM-HH:MM Y Y Y Y Y Y Y 7 HH:MM-HH:MM Y Y Y Y Y Y Y 8 HH:MM-HH:MM Y Y Y Y Y Y Y

2350REF01 NEC RSenCounter 4000 Reference Manual ◆ 63

Page 72: NEC4000 Programming

P-MODEP-MODE MENU STRUCTURE

● If none of the above effective period is applicable, then the price will default to the price level set in X-mode.

● If both FROM and TO time is 99:99, then this period will be ignored.

CONDIMENT TABLE [P5-7]Window 1

CONDIMENT TABLE [P5-7-1]

Window 2

PLU Price Level Scheduler [P5-6]: Programming fields and related flags.

Field Descriptor Default Explanation

CURRENT DEFAULT LEVEL IN X-MODE

Display only

PRICE EFFECTIVE: 24 hour clock

LEVEL

PERIOD

99:99 99:99 Starting time & inclusive

-99:99 99:99 Ending time & inclusive

SUN-SAT N

P-MODE:CONDIMENT TABLE (1/70)# DESCRIPTOR999 ABCDEFGHIJKL

Condiment Table [P5-7]: Programming fields and related flags.

Field Descriptor Default Explanation

# 1 Enter Cond. Table No. to access a Condi-ment Table.

DESCRIPTOR

P-MODE:CONDIMENT TABLE (1/3) TABLE # 999 1-(Memory Allocation) DESCRIPTOR XXXXXXXXXXXX TYPE OF SELECTION (0:LINE ITEM,1:QTY) 9 # OF SELECTION 99 ENFORCE # OF SELECTION Y COLOR OF TABLE (0-15) 99

PLU # DESCRIPTOR # 1 99999999999999 XXXXXXXXXXXXXXXX # 2 99999999999999 XXXXXXXXXXXXXXXX # 3 99999999999999 XXXXXXXXXXXXXXXX # 4 99999999999999 XXXXXXXXXXXXXXXX # 5 99999999999999 XXXXXXXXXXXXXXXX # 6 99999999999999 XXXXXXXXXXXXXXXX # 7 99999999999999 XXXXXXXXXXXXXXXX # 8 99999999999999 XXXXXXXXXXXXXXXX # 9 99999999999999 XXXXXXXXXXXXXXXX

64 ◆ NEC RSenCounter 4000 Reference Manual 2350REF01

Page 73: NEC4000 Programming

P-MODEP-MODE MENU STRUCTURE

● Condiment Table may hold Condiment and Memo Type PLU

● A maximum of 27 PLUs can be listed in the table.

P-MODE:CONDIMENT TABLE (2/3),(3/3)) TABLE # 999 1-(Memory Allocation) DESCRIPTOR XXXXXXXXXXXX TYPE OF SELECTION (0:LINE ITEM,1:QTY) 9 # OF SELECTION 99 ENFORCE # OF SELECTION Y COLOR OF TABLE (0-15) 99

PLU # DESCRIPTOR # 1 99999999999999 XXXXXXXXXXXXXXXX # 2 99999999999999 XXXXXXXXXXXXXXXX # 3 99999999999999 XXXXXXXXXXXXXXXX # 4 99999999999999 XXXXXXXXXXXXXXXX # 5 99999999999999 XXXXXXXXXXXXXXXX # 6 99999999999999 XXXXXXXXXXXXXXXX # 7 99999999999999 XXXXXXXXXXXXXXXX # 8 99999999999999 XXXXXXXXXXXXXXXX # 9 99999999999999 XXXXXXXXXXXXXXXX

Condiment Table [P5-7-1]: Programming fields and related flags.

Field Descriptor Default Explanation

TABLE # Enter the number to access another con-diment table.

DESCRIPTOR “COND. TBL 1” on the 1st. Rec.

only

Descriptor of this Table.

TYPE OF SELECTION 0 (line item)

# OF SELECTION 0 0 defaults to unlimited choice until ‘CLEAR’ key entered.

ENFORCE # OF SELECTION N If=Y, then do not accept ‘CLEAR’ key (0=Done = N)

COLOR OF TABLE 0 Display color pellet to choose from.

PLU # Enter Condiment PLU number to be at the location specified by the number.

Accept not only CONDIMENT but also PLU PREOPERTY REPORT TYPE = MEMO PLU.

DESCRIPTOR PLU Descriptor

2350REF01 NEC RSenCounter 4000 Reference Manual ◆ 65

Page 74: NEC4000 Programming

P-MODEP-MODE MENU STRUCTURE

CONDIMENT CHAIN [P5-8]

☞ [2][ENTER] or [DOWN ARROW][ENTER]

CONDIMENT CHAIN [P5-8-2]

● In the chain, a maximum of 12 condiment tables can be registered.

P-MODE:CONDIMENT CHAIN# DESCRIPTOR999 ABCDEFGHIJKL

Condiment Chain [P5-8]: Programming fields and related flags.

Field Descriptor Default Explanation

CHAIN # 1 Enter the chain number to access a record

DESCRIPTOR COND CHAIN 1 Display only

P-MODE:CONDIMENT CHAIN CHAIN # 999 1-(Memory Allocation) DESCRIPTOR XXXXXXXXXXXX

TABLE # DESCRIPTOR # 1 999 XXXXXXXXXXXX # 2 999 XXXXXXXXXXXX # 3 999 XXXXXXXXXXXX # 4 999 XXXXXXXXXXXX # 5 999 XXXXXXXXXXXX # 6 999 XXXXXXXXXXXX # 7 999 XXXXXXXXXXXX # 8 999 XXXXXXXXXXXX # 9 999 XXXXXXXXXXXX # 10 999 XXXXXXXXXXXX # 11 999 XXXXXXXXXXXX # 12 999 XXXXXXXXXXXX

Condiment Chain [P5-8-2]: Programming fields and related flags.

Field Descriptor Default Explanation

CHAIN # Jump to another chain for programming.

DESCRIPTOR “COND. CHAIN 1” on only on 1st.

Rec.

Enter descriptor for this chain.

TABLE # (12 TABLES MAX) Enter the 3 digit table number to be in this chain

1.5.9. LINKED PLU TABLE.

66 ◆ NEC RSenCounter 4000 Reference Manual 2350REF01

Page 75: NEC4000 Programming

P-MODEP-MODE MENU STRUCTURE

LINKED PLU TABLE [P5-9]

☞ [2][ENTER] or [DOWN ARROW][ENTER]

LINKED PLU TABLE (LPT) [P5-9-2]

● In the LINKED PLU TABLE, a maximum of 12 PLUs can be registered.

● The PLU in the LINKED PLU TABLE will not call another LINKED PLU TABLE.

● Nesting of the LINKED PLU TABLE is not allowed.

P-MODE:LINKED PLU TABLE# DESCRIPTOR999 ABCDEFGHIJKL

Linked PLU Table [P5-9]: Programming fields and related flags.

Field Descriptor Default Explanation

# 1 Enter LPT number.

DESCRIPTOR LINK PLU TBL 1 Display only

P-MODE:LINKED PLU TABLE LINKED PLU TABLE # 999 1-(Memory Allocation) DESCRIPTOR XXXXXXXXXXXX

PLU # DESCRIPTOR # 1 99999999999999 XXXXXXXXXXXXXXXX # 2 99999999999999 XXXXXXXXXXXXXXXX # 3 99999999999999 XXXXXXXXXXXXXXXX # 4 99999999999999 XXXXXXXXXXXXXXXX # 5 99999999999999 XXXXXXXXXXXXXXXX # 6 99999999999999 XXXXXXXXXXXXXXXX # 7 99999999999999 XXXXXXXXXXXXXXXX # 8 99999999999999 XXXXXXXXXXXXXXXX # 9 99999999999999 XXXXXXXXXXXXXXXX # 10 99999999999999 XXXXXXXXXXXXXXXX # 11 99999999999999 XXXXXXXXXXXXXXXX # 12 99999999999999 XXXXXXXXXXXXXXXX

Linked PLU Table [P5-9-2]: Programming fields and related flags.

Field Descriptor Default Explanation

LINKED PLU TABLE # Enter the LPT number to access another LINKED PLU TABLE.

DESCRIPTOR “LNK PLU TBL1” on the 1st. Rec.

only

Enter descriptor.

PLU# (12 PLUS MAX) Enter the PLU to be in this LPT.

2350REF01 NEC RSenCounter 4000 Reference Manual ◆ 67

Page 76: NEC4000 Programming

P-MODEP-MODE MENU STRUCTURE

DISCOUNT CATEGORY [P5-10]

● Maximum 99 fixed.

DISCOUNT CATEGORY [P5-10-1]

P-MODE:DISCOUNT CATEGORY Window 1# DESCRIPTOR99 ABCDEFGHIJKL

Discount Category [P5-10]: Programming fields and related flags.

Field Descriptor Default Explanation

# 1

DESCRIPTOR DISC CAT 1

P-MODE:DISCOUNT CATEGORY Window 2 DISCOUNT CATEGORY # 99 1-99 DESCRIPTOR XXXXXXXXXXXX

Discount Category [P5-10-1]: Programming fields and related flags.

Record

DISCOUNT CATEGORY # 00=DIABLED

DESCRIPTOR ‘DISC CAT 1” on 1st. Rec. only

68 ◆ NEC RSenCounter 4000 Reference Manual 2350REF01

Page 77: NEC4000 Programming

P-MODEP-MODE MENU STRUCTURE

PRINT PLU BY TBL, PRICE LIST, PRICE SCHEDULER [P5-11]

PLU PRICE LIST [P5-12-1] shows the printing format as follows;List plus and its Price, Sub Group number, PLU Property number in ascending order.

PLU BY PLU PROPERTY [P5-12-2] shows the printing format as follows;Group and list all plus together by PLU Property number.

P-MODE :PRINT PLU BY TBL, PRICE LIST, PRICE SCHEDULER1 PLU PRICE LIST2 PLU BY PLU PROPERTY3 PLU BY DISCOUNT CATEGORY4 PLU BY MENU LOOK UP5 PLUS BY PRICE TABLE6 PLUS PRICE TABLE7 PLUS PRICE SCHEDULER

*** PLU PRICE LIST ***TOTAL PLU = 0025/1500 The number of PLU

registered/PLU Mem. Alloc.

NO. PLU #DESCRIPTOR

PRICE SUB GRP#PLU PPTY#

-------------------------------------------------0001 12345678901234 999999.99 999

ABCDEFGHIJKLMNOP 9999 | |0025 12345678901234 999999.99 999

ABCDEFGHIJKLMNOP 9999-------------------------------------------------9999 STA. 10 BAR COUNTER

ANNIE 12/25/1999

*** PLU BY PLU PROPERTY ***TOTAL PLU PPTY = 0055/0100

PPTY# PPTY NAMEPLU #

DESCRIPTOR

-------------------------------------------------0001 APPETIZER

12345678901235 ABCDEFGHIJKLMNOP12345678901236 ABCDEFGHIJKLMNPO43211234567890 FEDCBAGHIJKLMNOP

0002 DRINK09876543214321 POABCDEFGGUHJNAB

| |0055 DESERT 12345678901234 ABCDEFGHIJKLMNOP-------------------------------------------------9999 STA. 10 BAR COUNTER

ANNIE 12/25/1999

2350REF01 NEC RSenCounter 4000 Reference Manual ◆ 69

Page 78: NEC4000 Programming

P-MODEP-MODE MENU STRUCTURE

PLU BY DISCOUNT CATEGORY [P5-12-3] shows the printing format as follows;Group and list all plus together by Discount Category number.

PLU BY Menu Look Up [P5-12-4] shows the printing format as follows;Group and list all plus together by MLU number.

*** PLU BY DISCOUNT CATEGORY***TOTAL DISCOUNT CATEGORY = 99

DC# DC NAMEPLU #

DESCRIPTOR

-------------------------------------------------01 SANDWICH

12345678901235 ABCDEFGHIJKLMNOP12345678901236 ABCDEFGHIJKLMNPO43211234567890 FEDCBAGHIJKLMNOP

02 LARGE DRINK09876543214321 POABCDEFGGUHJNAB

| |99 DESERT 12345678901234 ABCDEFGHIJKLMNOP-------------------------------------------------9999 STA. 10 BAR COUNTER

ANNIE 12/25/1999

*** PLU BY MLU***TOTAL MENU LOOK UP = 999 The number of MLU is from

S-Mode Mem. Alloc.

MLU# MLU NAMEPLU #

DESCRIPTOR

-------------------------------------------------001 SANDWICH

12345678901234 ABCDEFGHIJKLMNOP12345678901236 ABCDEFGHIJKLMNPO43211234567890 FEDCBAGHIJKLMNOP

002 LARGE DRINK09876543214321 POABCDEFGGUHJNAB

| |999 DESERT 12345678901234 ABCDEFGHIJKLMNOP-------------------------------------------------9999 STA. 10 BAR COUNTER

ANNIE 12/25/1999

70 ◆ NEC RSenCounter 4000 Reference Manual 2350REF01

Page 79: NEC4000 Programming

P-MODEP-MODE MENU STRUCTURE

PLU BY PRICE TABLE [P5-12-5] shows the printing format as follows;Group and list all plus together by Price Table number

PRICE Table [P5-12-6] shows the printing format as follows;List plus and its Price, Sub Group number, PLU Property number in ascending order.

*** PLU BY PRICE TABLE ***TOTAL PRICE TABLE = 999

TBL# TABLE NAMEPLU #

DESCRIPTOR

-------------------------------------------------001 BREAKFAST SP

12345678901234 ABCDEFGHIJKLMNOP12345678901236 ABCDEFGHIJKLMNPO43211234567890 FEDCBAGHIJKLMNOP

002 LUNCH SP09876543214321 POABCDEFGGUHJNAB

| |999 HAPPY HR SP 12345678901234 ABCDEFGHIJKLMNOP-------------------------------------------------9999 STA. 10 BAR COUNTER

ANNIE 12/25/1999

*** PLU PRICE TABLE ***TOTAL PRICE TABLE = 999 Price Tables Allocated in S-Mode

TBL# TABLE NAME --------------------------------------- 001 BREAKFAST SPLEVEL 1 $99999.99 LEVEL 5 $99999.99LEVEL 2 $99999.99 LEVEL 6 $99999.99LEVEL 3 $99999.99 LEVEL 7 $99999.99LEVEL 4 $99999.99 LEVEL 8 $99999.99

002 LUNCH SPLEVEL 1 $99999.99 LEVEL 5 $99999.99LEVEL 2 $99999.99 LEVEL 6 $99999.99LEVEL 3 $99999.99 LEVEL 7 $99999.99LEVEL 4 $99999.99 LEVEL 8 $99999.99|| 999 HAPPY HR SPLEVEL 1 $99999.99 LEVEL 5 $99999.99LEVEL 2 $99999.99 LEVEL 6 $99999.99LEVEL 3 $99999.99 LEVEL 7 $99999.99LEVEL 4 $99999.99 LEVEL 8 $99999.99---------------------------------------9999 STA. 10 BAR COUNTER ANNIE 12/25/1999

2350REF01 NEC RSenCounter 4000 Reference Manual ◆ 71

Page 80: NEC4000 Programming

P-MODEP-MODE MENU STRUCTURE

PRICE Scheduler [P5-12-7] shows the printing format as follows;

DOWNLOAD [P5-13]This is the same as Download Application Programs-Inventory [P13-1-6].

*** PLU PRICE SCHEDULER ***DEFAULT LEVEL # : 1 Default level set in

X-Mode

EFFECTIVE# FROM – TO SUN MON TUE WED THU FRI SAT---------------------------------------------------1 08:00-12:00 Y Y Y Y Y Y Y2 12:01-14:00 Y Y Y Y Y Y Y3 14:01-20:00 Y Y Y Y Y Y Y4 00:00-00:00 Y Y Y Y Y Y Y5 00:00-00:00 Y Y Y Y Y Y Y6 00:00-00:00 Y Y Y Y Y Y Y7 00:00-00:00 Y Y Y Y Y Y Y8 00:00-00:00 Y Y Y Y Y Y Y---------------------------------------------------9999 STA. 10 BAR COUNTER

ANNIE12/25/1999

72 ◆ NEC RSenCounter 4000 Reference Manual 2350REF01

Page 81: NEC4000 Programming

P-MODEP-MODE MENU STRUCTURE

INVENTORY [P6]

SPECIAL ITEM STOCK [P6-1-2]

☞ [P6-1-2-1][X/ENTER]

P-MODE :1 SPECIAL ITEM STOCK2345

P-MODE:SPECIAL ITEM STOCK# DESCRIPTOR QTY OUT999 ABCDEFGHIJKLMNOP 999999 YES

Special Item Stock [P6-1-2]: Programming fields and related flags.

Field Descriptor Default Explanation

# 1 Enter the SPECIAL ITEM STOCK number.

DESCRIPTOR PLU Descriptor

QTY

OUT

P-MODE:SPECIAL ITEM STOCK SPECIAL ITEM # 999 0-(Memory Allocation) PLU # 99999999999999 Check Validity DESCRIPTOR XXXXXXXXXXXX display only OUT OF STOCK Y STOCK QTY 999999 RESET AFTER Z1 Y QTY AFTER RESET 999999

Special Item Stock [P6-1-2-1]: Programming fields and related flags.

Field Descriptor Default Explanation

SPECIAL ITEM # 1

PLU#

DESCRIPTOR

OUT OF STOCK N If = Y, then this item will be out of stock regardless of its positive quantity. If = N, then it’s in stock even – stock quantity.

STOCK QTY.

RESET AFTER Z1

N If Y, then reset after Z1 Inventory

QTY AFTER RESET 0

2350REF01 NEC RSenCounter 4000 Reference Manual ◆ 73

Page 82: NEC4000 Programming

P-MODEP-MODE MENU STRUCTURE

MESSAGES [P7]

FIXED SCREEN MESSAGE ON ACTION LINE

The color will follow the TEXT, BACK COLOR of the Action Line. During Recording Macro, the color will be reversed between TEXT and BACK COLOR

SCREEN MESSAGE [P7-2]

SCREEN MESSAGE (SHORT) [P7-2-1]

● 15 messages per screen.

● Field length is 8 characters per message.

● Maximum of 200 messages allocated.

● Screen messages are left justified after trimming off trailing spaces.

P-MODE :MESSAGES1 SCREEN MESSAGE2 RECEIPT/CHECK MESSAGE3 KITCHEN PRINTER MESSAGE4 REPORT MESSAGE5 MONTH AND DAY MESSAGE

7 POLE DISPLAY8

No. P-Mode1 C-↑↓2 P-↑↓3 ENTER

4 EXIT

5 NEXT

6 PREV

R-Mode1 C-↑↓2 P-↑↓3 X/ENTER

4 DONE=EXIT

5 CLEAR

P-MODE :MESSAGES-SCREEN MESSAGE1 SCREEN MESSAGE (SHORT)2 SCREN MESSAGE (LONG)3 ERROR MESSAGE4 DEFAULT SYSTEM COLOR

P-MODE:SCREEN MESSAGE (SHORT)# USER DEFINED INTERNAL

999 ABCDEFGH ABCDEFGH

74 ◆ NEC RSenCounter 4000 Reference Manual 2350REF01

Page 83: NEC4000 Programming

P-MODEP-MODE MENU STRUCTURE

☞ [P7-2-1-1][X/ENTER]

Screen Message [P7-2-1]: Programming fields and related flags.

Field DescriptorDefault to Internal

DescriptorExplanation

# Enter the message number to access.

USER DEFINED

INTERNAL

P-MODE:SCREEN MESSAGE (SHORT) MESSAGE # (1-200) 999 INTERNAL MSG. XXXXXXXX USER DEFINED MSG. XXXXXXXX TEXT COLOR (0-15) 99

Screen Message [P7-2-1-1]: Programming fields and related flags.

RECORD:

MESSAGE #

INTERNAL MSG.

USER DEFINED MSG.

TEXT COLOR

Screen Message [P7-2-1-1]: Programming fields and related flags.

# Desc # Field Descriptor Text Color Used at

1 TABLE # 15 Information Line

2 GUEST # 15 Information Line

3 CHECK # 15 Information Line

4 NO DEST. 15 Information Line

5 EAT IN 15 Information Line

6 TAKE-OUT 15 Information Line

7 TRACK 1 15 Information Line

8 TRACK 2 15 Information Line

9 DRIVE TH 15 Information Line

10 PR LVL 1 15 Status Line

11 PR LVL 2 15 Status Line

12 PR LVL 3 15 Status Line

13 PR LVL 4 15 Status Line

2350REF01 NEC RSenCounter 4000 Reference Manual ◆ 75

Page 84: NEC4000 Programming

P-MODEP-MODE MENU STRUCTURE

14 PR LVL 5 15 Status Line

15 PR LVL 6 15 Status Line

16 PR LVL 7 15 Status Line

17 PR LVL 8 15 Status Line

18 KB LVL 1 15 Status Line

19 KB LVL 2 15 Status Line

20 KB LVL 3 15 Status Line

21 KB LVL 4 15 Status Line

22 KB LVL 5 15 Status Line

23 KP LVL 1 15 X/Enter Status Window

24 KP LVL 2 15 X/Enter Status Window

25 KP LVL 3 15 X/Enter Status Window

26 KP LVL 4 15 X/Enter Status Window

27 KP LVL 5 15 X/Enter Status Window

28 STA# 15 X/Enter Status Window

STA# 15 Trans. Void Window

29 ORDER # 15 Information Line

ORDER # 15 Trans. Void Window

30 TRACK # 15 Information Line

TRACK # 15 Action Line

31 TOTAL 15 Item Line (Customer)

TOTAL 15 PO/RA Window

TOTAL 15 SEAT # Selection Window

32 CHANGE 15 Action Line (Customer)

33 TAXES 15 Item Line

34 PBAL 15 Item Line

35 AMT DUE 15 Action Line

AMT DUE 15 Charge Window

36 CASH 15 Item Line (Customer)

CASH 15 PO/RA Window

CASH 15 Action Line (RA/PO, Adj. Tender)

37 CHECK 15 Item Line (Customer)

CHECK 15 PO/RA Window

CHECK 15 Action Line (RA/PO, Adj. Tender)

38 CHARGE 15 Item Line (Customer)

CHARGE 15 PO/RA Window

Screen Message [P7-2-1-1]: Programming fields and related flags.

# Desc # Field Descriptor Text Color Used at

76 ◆ NEC RSenCounter 4000 Reference Manual 2350REF01

Page 85: NEC4000 Programming

P-MODEP-MODE MENU STRUCTURE

CHARGE 15 Action Line (RA/PO, Adj. Tender)

39 PAID 15 Item Line (Where is "= = = = = =" ???)

40 TRAINING 15 Action Line

41 MGR 15 Action Line

42 GRILL 15 Action Line

43 WASTE 15 Action Line (To be Deleted ? Use Func-tion Desc.)

44 CLOSED 15 Close Screen (Customer)

45 PLUSHIFT 15 PLU Shift Window Title

46 FREE 15 Item Line

47 SERVICED 15 Item Line? SVC Key window

48 TIPS : 15 Charge Window

49 ACCT# : 15 Charge Window

50 AUTH# : 15 Charge Window

51 TENDER : 15 To be Deleted? AMT DUE is used in Charge Window

52 CHGTIP 15 Charge Window

53 BALANCE 15

54 EXPIR. 15 Charge Window

55 REF 15

56 STOCK= 15

57 NON PROD 15

58 GROUP 15 X/ENTER Window

59 TYPE 15 X/ENTER Window

60 SHIFT 15 X/ENTER Window-Title

61 SHIFT1 15 X/ENTER Window

62 SHIFT2 15 X/ENTER Window

63 SHIFT3 15 X/ENTER Window

64 SHIFT4 15 X/ENTER Window

65 SHIFT5 15 X/ENTER Window

66 SHIFT6 15 X/ENTER Window

67 SHIFT7 15 X/ENTER Window

68 SHIFT8 15 X/ENTER Window

69 SHIFT9 15 X/ENTER Window

70 DATE 15 X/ENTER Window

71 SEND TO 15 X/ENTER Window

72 RCEPT 15 X/ENTER Window

Screen Message [P7-2-1-1]: Programming fields and related flags.

# Desc # Field Descriptor Text Color Used at

2350REF01 NEC RSenCounter 4000 Reference Manual ◆ 77

Page 86: NEC4000 Programming

P-MODEP-MODE MENU STRUCTURE

73 JRNAL 15 X/ENTER Window

74 15

75 KP LEVEL 15 X/ENTER Window

76 QS 15 TRANSACTION VOID Window

77 TBL# 15 ADD CHECK / LIST CHECK / COMB. TABLES Window

78 CHK# 15 ADD CHECK / LIST CHECK / COMB. TABLES Window

79 GST# 15 ADD CHECK / LIST CHECK / COMB. TABLES Window

80 OPEN 15 ADD CHECK / LIST CHECK / COMB. TABLES Window

81 ELAPSE 15 ADD CHECK / LIST CHECK / COMB. TABLES Window

82 SERVER 15 ADD CHECK / LIST CHECK / COMB. TABLES Window

83 SEAT# 15 SERVICE BY SEAT# Window

84 SUBTOTAL 15 SERVICE BY SEAT# Window

85 TAX 15 SERVICE BY SEAT# Window

86 SEAT 15 SERVICE BY SEAT# Window

87 RECALL 15 Information Line

88 OPEN 15 Information Line

89 MORE-> 15 Item Line

90 <-MORE 15 Item Line

91 DEBIT 15 Item Line (Customer)

92 G.C. REDM 15 Item Line (Customer)

93 TRACK 1 15 TRANSACTION VOID Window

94 TRACK 2 15 TRANSACTION VOID Window

95 CHECK 15 TRANSACTION VOID Window

96 SELECT : 15 TRANSFER CHECK/Time Keeping

97 FROM : 15 TRANSFER CHECK

98 TO : 15 TRANSFER CHECK

99 SYSTEM 15 R-MODE SIGN ON BY SYSTEM PASS WORD

100 IN 15 TIME KEEPING R-MODE/X-MODE EDIT

101 OUT 15 TIME KEEPING R-MODE/X-MODE EDIT

102 SUMMARY 15 TIME KEEPING

Screen Message [P7-2-1-1]: Programming fields and related flags.

# Desc # Field Descriptor Text Color Used at

78 ◆ NEC RSenCounter 4000 Reference Manual 2350REF01

Page 87: NEC4000 Programming

P-MODEP-MODE MENU STRUCTURE

103 JOB 15 TIME KEEPING R-MODE/X-MODE EDIT

104 BREAK 15 TIME KEEPING R-MODE/X-MODE EDIT

105 REGULAR 15 TIME KEEPING

106 OT 15 TIME KEEPING

107 TOTAL 15 TIME KEEPING

108 HOLIDAY 15 TIME KEEPING

109 PREMIUM 15 TIME KEEPING

110 OPEN 15 TIME KEEPING X-MODE EDIT

111 DESCR. 15 TIME KEEPING X-MODE EDIT

112 MINOR 1 15 TIME KEEPING

113 MINOR 2 15 TIME KEEPING

114 MESSAGE: 15 TIME KEEPING

115 DAY # 15 TIME KEEPING

116 LB 15 SCALE

118 TARE 15 SCALE

119 WEIGHT 15 SCALE

120 PLU # NEW PLU

121 PRICE NEW PLU

122 TIME

123 CANCELLED DT INFORMATION

124 MODIFY DT INFORMATION

125 SERVED DT INFORMATION

126 CONTINUE REPORT CONSOLIDATION

127 STOP REPORT CONSOLIDATION

128 OPEN PLU INQUIRY

129 ORDER # 15 ORDER #

Screen Message [P7-2-1-1]: Programming fields and related flags.

# Desc # Field Descriptor Text Color Used at

2350REF01 NEC RSenCounter 4000 Reference Manual ◆ 79

Page 88: NEC4000 Programming

P-MODEP-MODE MENU STRUCTURE

SCREEN MESSAGE (LONG) [P7-2-2]

☞ [P7-1-2-1][X/ENTER]

● Screen messages are left justified after trimming off trailing spaces.

● Field length is 16 characters per message.

● Maximum of 100 messages allocated.

P-MODE:SCREEN MESSAGE (LONG)# USER DEFINED INTERNAL

999 ABCDEFGHIJKLMNOP ABCDEEFGHIJKLMOP

Screen Message (Long) [P7-2-2]: Programming fields and related flags.

Field Descriptor Default to

Internal Descriptor Explanation

# Enter the message number to access.

USER DEFINED

INTERNAL

P-MODE:SCREEN MESSAGE (LONG) MESSAGE # (1-100) 99 INTERNAL MSG. XXXXXXXXXXXXXXXX USER DEFINED MSG. XXXXXXXXXXXXXXXX TEXT COLOR (0-15) 99

Screen Message (Long) [P7-2-2-1]: Programming fields and related flags.

Field Descriptor Default to

Internal Descriptor Explanation

MESSAGE #

INTERNAL MSG.

USER DEFINED MSG.

TEXT COLOR

80 ◆ NEC RSenCounter 4000 Reference Manual 2350REF01

Page 89: NEC4000 Programming

P-MODEP-MODE MENU STRUCTURE

Screen Message (Long) [P7-2-2-1]: Programming fields and related flags.

# Desc # Field Descriptor Text Color Used at

1 ENTER EMPL. CODE 15

2 SWIPE CARD 15

3 RPTs TO PRINTER 15

4 RPTs TO SCREEN 15

5 UNDER TENDER 15

8 [EXIT] TO LEAVE 15 Action Line

9 SELECT ITEM 15 Action Line

10 ENTER QTY. 15 Action Line

11 TABLE SVC 15 X/ENTER Window

12 QS COUNTER 15 X/ENTER Window

13 DT OT 15 X/ENTER Window

14 DT CSHR 15 X/ENTER Window

15 DT OT CSHR 15 X/ENTER Window

16 CLOSE TIME 15 TRANSACTION VOID Window

17 EMPLOYEE # 15 TRANSACTION VOID Window

18 TRANS.TYPE 15 TRANSACTION VOID Window

19 OPEN TIME 15 TRANSACTION VOID Window

20 ENTER BEGIN CASH 15 BEGIN CASH WINDOW

21 ENTER CASH PULL 15 CASH PULL WINDOW

22 CHECK/ORDER # 15 ADJ. TENDER Window

23 INCORRECT AMOUNT 15 ADJ. TENDER Window

24 WRONG TENDER KEY 15 ADJ. TENDER Window (INCORR. KEY in Receipt Message)

25 NEW TENDER KEY 15 ADJ. TENDER Window (COR-RECT KEY in Receipt Message)

26 ENTER ADV.DEPST 15 ADVANCE DEPOSIT Window

27 SHARED BY? 15 SHARE ITEM Window

28 ENTER NEW TABLE# 15 COMB. TABLES Window

29 COMBINED 15 COMB. TABLES Window

30 FROM CSHR/SVR 15 TRANSFER CHK Window

31 TO CSHR/SVR 15 TRANSFER CHK Window

32 SELECT 15 SVC Window

33 ONE CHK – NO SEATS 15 SVC Window

34 ONE CHK – ALL 15 SVC Window

2350REF01 NEC RSenCounter 4000 Reference Manual ◆ 81

Page 90: NEC4000 Programming

P-MODEP-MODE MENU STRUCTURE

35 SPLIT CHK-SELECT 15 SVC Window

36 SPLIT CHK-ALL 15 SVC Window

37 SPLIT CHK-ITEM 15 SVC Window

38 DECLARE TIPS 15 DECLARE TIP Window/Time Keeping

39 CASH TIPS 15 DECLARE TIP Window

40 ENTER KP MESSAGE 15 KP MESG WINDOW

41 ALPHA OFF !! 15

42 ENTER AMOUNT 15

43 ENTER $ OR % 15

44 ALL CHECKS 15 TRANSFER CHECK

45 SELECTED CHECKS 15 TRANSFER CHECK

46 CHECK TRANSFERRED 15 AFTER TRANSFER CHECK

47 SPLIT CHECK 15 AFTER SPLIT CHECK

48 ENTER SVC 15

49 CSHR/SVR# 15 CHG TIP PAID

50 TIPS PAID OUT 15 CHG TIP PAID

51 OUT OF STOCK 15 Special Inventory

52 (0=N 1=Y) 15 Special Inventory

53 CLOSED DATE 15 TIME KEEPING Z/X

54 SELECT JOB# 15 TIME KEEPING

55 OUT FOR DAY 15 TIME KEEPING

56 ACCUMULATED HRS 15 TIME KEEPING

57 DECLARED TIPS 15 TIME KEEPING

58 SELECT, THEN 15 TIME KEEPING (12 Character Display)

59 INTERRUPTION 15

60 NETWORK ONLINE 15 PRESS [X/TIME] IN OFF MODE

61 WEIGHING… 15 SCALE

62 ENTER WEIGHT 15 SCALE

63 ENTER TARE 15 SCALE

64 PLU PPTY # 15

65 HOLD ITEMS 15

66 HELD ITEMS SENT 15

67 AREA FULL, Z CTS 15

68 ENTER TABLE/CHK 15

69 NO PAPER OR OFF! PRINTER ERROR

Screen Message (Long) [P7-2-2-1]: Programming fields and related flags.

# Desc # Field Descriptor Text Color Used at

82 ◆ NEC RSenCounter 4000 Reference Manual 2350REF01

Page 91: NEC4000 Programming

P-MODEP-MODE MENU STRUCTURE

ERROR MESSAGE [P7-2-3] 1

ERROR MESSAGE [P7-2-3-1] 1

● Messages are left justified after trimming off trailing spaces.

● Field length is 32 characters per message.

● Maximum of 200 messages allocated.

70 PRINTER IS BUSY! PRINTER ERROR

71 POWER FAIL! PRINTER ERROR

72 BACKUP PRINTER PRINTER ERROR

73 CANCEL PRINT PRINTER ERROR

74 DT CONF. BOARD SCORE BOARD CHECK

75 RS232C COMM.ERR! SCORE BOARD CHECK

76 LAN COMM. ERROR! SCORE BOARD CHECK, PRINTER ERROR

77 RETRY SCORE BOARD CHECK, PRINTER ERROR

78 CANCEL SCORE BOARD CHECK

79 START PREPOLL AUTO PRE-POLL

80 LAN COMM. RE-TRY COMMUNICATION

81 ENT PLU#/PLU KEY PLU INQUIRY

P-MODE:ERROR MESSAGE# USER DEFINED

999 ABCDEFGHIJKLMNOPQRSTUVWXYZ123456

Error Message [P7-2-3]: Programming fields and related flags.

Field DescriptorDefault to Field

Descriptor Message

Explanation

# Enter the message number to access.

USER DEFINED

P-MODE:ERROR MESSAGE ERROR MESSAGE # (1-200) 999 USER ERROR MESSAGE

XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX TEXT COLOR (0-15) 99

Screen Message (Long) [P7-2-2-1]: Programming fields and related flags.

# Desc # Field Descriptor Text Color Used at

2350REF01 NEC RSenCounter 4000 Reference Manual ◆ 83

Page 92: NEC4000 Programming

P-MODEP-MODE MENU STRUCTURE

Error Message [P7-2-3-1]: Programming fields and related flags.

MESSAGE #

INTERNAL MSG.

USER DEFINED MSG.

TEXT COLOR

Error Message [P7-2-3-1]: Programming fields and related flags.

# Desc # Field Descriptor Text Color Used at

1 ERROR 15 Many places

2 OVER LIMIT 15 Many places

3 ENTER NUMBER 15

4 SIGN-ON IN R-MODE 15

5 ENTER AMOUNT 15

6 DRAWER LIMIT 15

7 MANAGER REQUIRED 15 R-Mode

8 COMM. BUSY 15

9 CLOSE DRAWER 15

10 ENTER GRILL 15

11 ENTER SHIFT TYPE 15

12 ENTER SERVE/PARK 15

13 INVALID ENTRY 15 Many places

14 ENTER SEAT# 15

15 BUFFER FULL 15 R-Mode

16 ENTER CONDIMENT 15 Condiment

17 NO DATA 15

18 ALLOCATION OVER 15

19 ENTER DESTINATION 15

20 ENTER # KEY 15

21 ENTER TENT # 15

22 ENTER # OF GUESTS 15

23 INVALID COUPON 15

24 NOT ELIGIBLE 15

25 SHIFT TYPE MISMATCH 15 PLU Sale

26 FINALIZE STORED ORDERS 15

27 CASH DECLARE REQUIRED 15

28 NOT FOUND IN A FILE 15 Many places

84 ◆ NEC RSenCounter 4000 Reference Manual 2350REF01

Page 93: NEC4000 Programming

P-MODEP-MODE MENU STRUCTURE

29 ENTER TIME 15

30 NOT MACRO KEY 15 Macro

31 NOT FUNCTION KEY 15

32 MACRO COUNT OVER 15 Macro

33 NUMERIC ENTRY ERROR 15

34 QUANTITY ENTRY ERROR 15

35 PRESS PLU KEY 15

36 NOT ON KEYBOARD LEVEL1 15 R-Mode

37 NOT ON KEYBOARD LEVEL2 15 R-Mode

38 NOT ON KEYBOARD LEVEL3 15 R-Mode

39 NOT ON KEYBOARD LEVEL4 15 R-Mode

40 NOT ON KEYBOARD LEVEL5 15 R-Mode

41 COMM.ERROR 15

42 ORDER OVER FLOW 15

43 DUPLICATE NUMBER 15

44 TRACK # RECALLED 15

45 OUTDATED DATA IN MASTER 15

46 OUTDATED DATA IN BACK-UP 15

47 ENTER TRACK # 15

48 ENTER STORE 15

49 ENTER JOB # 15

50 TRACK # MISMATCH 15

51 PROCESSING… 15

52 STATUS CLEAR 15

53 OUT OF STOCK 15

54 INPUT QTY 15

55 ENTER SBTL 15

56 FINISH ORDER 15

57 PLEASE WAIT 15

58 PROCESSING…KVS 15

59 KVS ERROR ! 15

60 SYSTEM LOG BUFFER FULL 15

61 TRANSACTION LOG BUFFER FULL 15

62 ENTER TIP 15

63 ENTER ACCT.# 15

64 ENTER AUTH.# 15

Error Message [P7-2-3-1]: Programming fields and related flags.

# Desc # Field Descriptor Text Color Used at

2350REF01 NEC RSenCounter 4000 Reference Manual ◆ 85

Page 94: NEC4000 Programming

P-MODEP-MODE MENU STRUCTURE

65 NO DRAWER ASSIGNED 15

66 ENTER QTY,X/ENTER,$,ITEM 15

67 ENTER CHECK # 15

68 ENTER TABLE # 15

69 ENTER CHK# OR TBL# 15

70 INVALID AUTHORITY LEVEL 15 Many places

71 ENTER CLOCK-IN 15

72 INCORRECT DATA 15

73 CLOSE OPEN CHECKS 15

74 ENTER EXPIR. DATE 15

75 15

76 15

77 PLACE ITEM ON SCALE 15

78 ITEM IS NOT A SCALE ITEM 15

79 ZERO ERROR 15

80 SCALE IS LB.,REG IS KG. 15

81 SCALE IS KG.,REG IS LB. 15

82 WEIGHT IS OVER LIMIT 15

83 NEGATIVE WEIGHT 15

84 MOTION ERROR 15

85 SCALE COMM. ERROR 15

86

87

88 ENTER [SVC] or [TENDER KEY] 15

89 LINKED PLU TABLE NOT ALLOWED 15

90 1

91 PLEASE SWIPE AGAIN 15

92 INVALID CARD 15

93 *** CHANGE ORDER *** 15

94 *** KVS BACK-UP *** 15

95 CARD HAS EXPIRED 15

96 EMPLOYEE # RECALLED 15

97 15

98 15

99 NOT MENU KEY 15

100 INCORRECT REGISTER 15

Error Message [P7-2-3-1]: Programming fields and related flags.

# Desc # Field Descriptor Text Color Used at

86 ◆ NEC RSenCounter 4000 Reference Manual 2350REF01

Page 95: NEC4000 Programming

P-MODEP-MODE MENU STRUCTURE

101 ENTER ACTUAL INVENTORY 15

102 REGISTER BEGIN QUANTITY 15

103 PORT # IS NOT PROGRAMMED 15

104 TIMER IS NOT PROGRAMMED 15

105 UNDER TENDER DISALLOWED 15

106 CTF RECOVERING…(RCV) 15

107 CLOSE TIP ENTRY 15

108 VOID COUPON FIRST 15

109 ENTER AMOUNT or % 15

110 REENTER A COUPON 15

111 CLOSE TIPS BEFORE VOID 15

112 OVER TENDER DISALLOWED 15

113 COND.TBL OVER FLOW 15 Condiment

114 INVALID OPEN TIME 15 Transaction Void

115 INVALID CLOSE TIME 15 Transaction Void

116 INVALID STATION# 15 Transaction Void

117 INVALID EMPL# OF CSHR/SVR 15 Transaction Void

118 INVALID TRANS. TYPE 15 Transaction Void

119 INVALID SELECTION 15

120 VOID ITEM DISC. FIRST 15

121 ALREADY DISCOUNTED 15

120 VOID ITEM DISC. FIRST 15 Voiding Condiment PLU with discount

121 ALREADY DISCOUNTED 15 Discount the discounted item

122 ENTER TRAY SUBTOTAL 15 Tender key on Tray Subto-tal transaction

123 VOID ORDER DISC. FIRST 15

124 VOID SURCHARGE FIRST 15 Surcharge

125 VOID AUTO-COMBO FIRST 15 Auto-combo

126 CHECK RECALLED 15

127 CHECK POLE DISPLAY 15

128 INVALID AUTO-COMBO 15 Auto-combo

129 POLL CTS FROM SYS MASTER 15 Closed Transaction sum-mary Memory Alloc. Full

130 TRANS. LOG BUFFER FULL 15

131 INVALID INTERRUPTION 15 Clerk interruption

Error Message [P7-2-3-1]: Programming fields and related flags.

# Desc # Field Descriptor Text Color Used at

2350REF01 NEC RSenCounter 4000 Reference Manual ◆ 87

Page 96: NEC4000 Programming

P-MODEP-MODE MENU STRUCTURE

132 SETTLE BATCH AFTER THIS TRANS. 15

133 MODEM # NOT PROGRAMMED 15

134 CREDIT TRACKING FILE RECALLED 15

135 OUTDATED DT ORDER IN CS OR OT/CS

15

136 ORDER IN PROCESS 15

137 CHECK ! RS232C CONFIG. 15

138 TYPE OF ORDER? 15

139 SERVE ORDER FIRST

140 LINKED TABLE CALLED ILLEGALLY

141 FOLLOWING STAS ARE NOT ONLINE COMMUNICATION ERROR AT CLOSE-MODE [X/ENTER]

142 NO REPONSE COMMUNICATION ERROR

143 CD ERROR SCANNER

144 TAKE MIN. BREAK, PRESS [CANCEL] 15 CLOCK IN IF UNDER REQUIRED BREAK TIME

Error Message [P7-2-3-1]: Programming fields and related flags.

# Desc # Field Descriptor Text Color Used at

88 ◆ NEC RSenCounter 4000 Reference Manual 2350REF01

Page 97: NEC4000 Programming

P-MODEP-MODE MENU STRUCTURE

DEFAULT SYSTEM COLOR [P7-2-4]

1

RECEIPT/GUEST CHECK MESSAGE [P7-3]

P-MODE:DEFAULT SYTEM COLORWINDOW BACK COLOR :

SCREEN MESSAGE-SHORT (0-15) 99SCREEN MESSAGE-LONG (0-15) 99ERROR MEESAGE (0-15) 99SCREEN BACK COLOR (0-15) 99

WINDOW LINE COLOR :CONDIMENT TABLE WINDOW (0-15) 99MLU TABLE WINDOW (0-15) 99TLU WINDOW (0-15) 99PLU SHIFT WINDOW (0-15) 99

Default System Color [P7-2-4]: Programming fields and related flags.

Field Descriptor TEXT COLOR EXPLANATION

SHORT SCREEN MESSAGE-SHORT

0 Select the color of the background from the pellet list.

SCREEN MESSAGE-LONG

0 Ditto

SCREEN ERROR MESSAGE 0 Ditto

SCREEN BACK COLOR 0 Ditto

CONDIMENT TABLE WINDOW 15 Ditto

MLU TABLE WINDOW 15 Ditto

TLU WINDOW 15 Ditto

PLU SHIFT WINDOW 15 Ditto

P-MODE :MESSAGES-RECEIPT/GUEST CHECK MESSAGES1 RECEIPT/GUEST CHECK HEADER AND FOOTER2 RECEIPT/GUEST CHECK SYSTEM DESCRIPTOR3 CREDIT CARD AGREEMENT MESSAGE (CHARGE)4 CREDIT CARD AGREEMENT MESSAGE (CREDIT)5 GUEST CHECK TRAIL MESSAGE

2350REF01 NEC RSenCounter 4000 Reference Manual ◆ 89

Page 98: NEC4000 Programming

P-MODEP-MODE MENU STRUCTURE

RECEIPT/GUEST CHECK HEADER AND FOOTER [P7-3-1]

RECEIPT/GUEST CHECK SYSTEM MESSAGE [P7-3-2]

1

● Messages are left justified after trimming off trailing spaces.

● 15 messages per screen.

● Field length is 12 characters per message.

● Maximum of 100 messages allocated.

Receipt/Guest Check System Message [P7-3-2-1]

P-MODE:RECEIPT/GUEST CHECK HEADER AND FOOTER

HEADER : XXWELCOME TO THE NEC RSenCounter 4000!XX XXXXXXXXXXXRESTAURANT SYSTEMXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX

FOOTER : XXXXXXXXXXXXXTHANK YOU !XXXXXXXXXXXXXXXX XXXXXXXXXXXXXCOME AGAIN.XXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX

Receipt/Guest Check Header and Footer [P7-3-1]: Programming fields and related flags.

Field Descriptor Default Explanation

HEADER

LINE # 1 Refer to Screen P7-3-1

Enter the Receipt header 40 characters X 6 lines

FOOTER

LINE # 1 Refer to Screen P7-3-1

Enter the Receipt footer 40 characters X 6 lines.

P-MODE:RECEIPT/GUEST CHECK SYSTEM MESSAGE# USER DEFINED INTERNAL

999 ABCDEFGHIJKL ABCDEFGHIJKL

P-MODE:RECEIPT/GUEST CHECK SYSTEM MESSAGE MESSAGE # (1-150) 999 INTERNAL MSG. XXXXXXXXXXXX USER DEFINED MSG. XXXXXXXXXXXX TEXT COLOR (0-15) 99

90 ◆ NEC RSenCounter 4000 Reference Manual 2350REF01

Page 99: NEC4000 Programming

P-MODEP-MODE MENU STRUCTURE

Receipt/Guest Check System Message [P7-3-2]: Programming fields and related flags.

Field Descriptor Default Explanation

# Enter message # to access

USER DEFINED

INTERNAL

Receipt/Guest Check System Message [P7-3-2-1]:Programming fields and related flags.

Desc # Field Descriptor Used at Limit

1 ORDER# QS In Double Width

2 *** COPY *** COMMON

3 TOTAL COMMON

4 CHANGE COMMON

5 TAX COMMON

6 TAXABLE COMMON

7 NON-TAXABLE COMMON

8 TAX TOTAL COMMON

9 BAKED GOODS COMMON

10 TBL# TS 4

11 #GST TS 4

12 CHK# TS 4

13 CHARGE TIP TS RECEIPT

14 ALL TS receipt

15 SEAT # Split check by Seat# 6

16 PARTIAL Split check by Seat#

17 SPLIT RCPT SPLIT PAYMENT RECEIPT

18 STA# TS & QS/TRANSACTION VOID 4

19 / BY Receipt of Share item 4

20 FOR Receipt for Base Qty 4

21 TRAY ORDER# Tray Subtotal

22 TRANS. TYPE: TRANS. VOID

23 QS TRANS. VOID

24 TRACK 1 TRANS. VOID/TRAY SUBTOTAL ON RECALL ORDER

25 TRACK 2 TRANS. VOID/TRAY SUBTOTAL ON RECALL ORDER

26 CHECK TRANS. VOID

2350REF01 NEC RSenCounter 4000 Reference Manual ◆ 91

Page 100: NEC4000 Programming

P-MODEP-MODE MENU STRUCTURE

27 OPEN TIME : TRANS. VOID

28 CLOSE TIME : TRANS. VOID

29 REPORTED TO TRANS. VOID

30 TIME Add Check/Transfer Check 4

31 BALANCE Add Check/Transfer Check 8

32 FROM SERVER# TRANSFER CHECK

33 TO SERVER# TRANSFER CHECK/ CHARGE TIP PAID RECEIPT

34 H=HELD ITEMS TRASFER CHECK

35 RECEIVED BY ADVANCE DEPOSIT

36 RECEIPT# ADVANCE DEPOSIT

37 CHECK/ORDER# ADJUST TENDER CHIT(NEW)

38 AMOUNT ADJ. TENDER RCPT/TS RCPT.

39 INCORR. KEY ADJUST TENDER CHIT

40 CORRECT KEY ADJUST TENDER CHIT

41 CASH BEGIN CASH/CASH PULL(NEW)

42 CASH DECL’N CASH DECLARATION CHIT

43 CHECK DECL’N CHECK DECLARATON CHIT

44 CASH TIP CASH TIP DECLARATION

45 TIPS DECL’D CASH TIP DECLARATION /TK EDIT

46 CHG TIP PAID CHARGE TIP PAID RECEIPT

47 GRS CHRG TPS CHARGE TIP PAID RECEIPT

48 CC TIPS FEE CHARGE TIP PAID RECEIPT

49 NET CHRG TPS CHARGE TIP PAID RECEIPT

50 ACCOUNT# : CREDIT CARD RECEIPT

51 EXP. DATE : CREDIT CARD RECEIPT

52 AUTH# : CREDIT CARD RECEIPT

53 APPROVAL# : CREDIT CARD RECEIPT

54 REFERENCE# : CREDIT CARD RECEIPT

55 CARD CREDIT CARD RECEIPT

56 TOP COPY CREDIT CARD RECEIPT

57 BOTTOM COPY CREDIT CARD RECEIPT

58 MERCHANT CREDIT CARD RECEIPT

59 CUSTOMER CREDIT CARD RECEIPT

60 // CREDIT CARD RECEIPT

61 TIP CREDIT CARD RECEIPT

Receipt/Guest Check System Message [P7-3-2-1]:Programming fields and related flags.

Desc # Field Descriptor Used at Limit

92 ◆ NEC RSenCounter 4000 Reference Manual 2350REF01

Page 101: NEC4000 Programming

P-MODEP-MODE MENU STRUCTURE

62 SIGNATURE CREDIT CARD RECEIPT

63 PRICE CHANGE PRICE EDIT CHIT

64 PPTY DESCR. PRICE EDIT CHIT

65 PPTY# PRICE EDIT CHIT

66 PLU DESCR. PRICE EDIT CHIT

67 PLU# PRICE EDIT CHIT

68 OLD PRICE PRICE EDIT CHIT

69 NEW PRICE PRICE EDIT CHIT

70 TIME EDIT TIME KEEPING EDIT

71 EMPL. FILE# TIME KEEPING EDIT

72 RECORD OF : TIME KEEPING EDIT

73 BEFORE TIME KEEPING EDIT

74 AFTER TIME KEEPING EDIT

75 IN TIME KEEPING EDIT

76 OUT TIME KEEPING EDIT

77 BREAK OUT TIME KEEPING EDIT

78 HOLIDAY TIME KEEPING EDIT

79 MINOR 1 TIME KEEPING EDIT

80 MINOR 2 TIME KEEPING EDIT

81 MESSAGE: TIME KEEPING EDIT

82 REG: TIME KEEPING EDIT 4

83 OT : TIME KEEPING EDIT 4

84 TRAINING TIME KEEPING EDIT

85 PREMIUM TIME KEEPING EDIT

86 TOTAL HOURS TIME KEEPING EDIT

87 CHANGE ORDER When item sent to KP is voided.

88 QTY. KP, FLAG DEPENDENT

89 FC Foreign Currency 2

90 LC Local Currency 2

91 EMPL. EDIT Employee File Edit

92 CHANGED Employee File Edit

93 NAME Employee File Edit

94 ACTIVE Employee File Edit

95 BIRTH DATE Employee File Edit

96 CLASS Employee File Edit

Receipt/Guest Check System Message [P7-3-2-1]:Programming fields and related flags.

Desc # Field Descriptor Used at Limit

2350REF01 NEC RSenCounter 4000 Reference Manual ◆ 93

Page 102: NEC4000 Programming

P-MODEP-MODE MENU STRUCTURE

97 CSHR/SVR # Employee File Edit

98 SOC. SEC.# Employee File Edit

99 KEY CODE Employee File Edit

100 PHONE # Employee File Edit

101 AUTH. LEVEL Employee File Edit

102 AT TIME KPG Employee File Edit

103 TIP DECL’N Employee File Edit

104 JOB DECL’N Employee File Edit

105 PAY RATE EDT Employee Pay Rate Edit

106 INTERRUPT BY CLERK INERRUPT

107 AUTO SAVED AUTO INTERRUPT

108 SPLIT FROM SPLIT CHECK

109 BRK TIME KEEPING 4

110 JOB DESCR. TIME KEEPINT

111 JOB CODE EMPLOYEE FILE EDIT

112 RATE CODE EMPLOYEE FILE EDIT

113 DAY # TIME KEEPING EDIT

114 SPLIT PAY Split Payment (CC Settlement form)

115 QUEUED ORDER

116 Lb21

117 kgs.

118 EMPL. LIST

119 CSHR/SVR LIST

120 INACTIVE

121 POWER FAIL POWER FAIL

122 SYSTEM RECEIPT FOOTER WHEN THE “SYS-TEM” SIGNS ON.

123 KVS BACK-UP KVS BACK UP PRINT

124 PRICE NEW PLU

Receipt/Guest Check System Message [P7-3-2-1]:Programming fields and related flags.

Desc # Field Descriptor Used at Limit

94 ◆ NEC RSenCounter 4000 Reference Manual 2350REF01

Page 103: NEC4000 Programming

P-MODEP-MODE MENU STRUCTURE

CREDIT CARD AGREEMENT MESSAGE (CHARGE) [P7-3-3]

● Field length is 40 characters per line.

● Maximum of 6 lines are allocated.

CREDIT CARD AGREEMENT MESSAGE (CREDIT) [P7-3-4]

● Field length is 40 characters per line.

● Maximum of 12 lines are allocated.

P-MODE:CREDIT CARD AGREEMENT MSG. (CHARGE)

I hereby approve all charges, and by signing this document have agreed to the charges, and full payment of these charges for which I am billed. XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX

Credit Card Agreement Message [P7-3-3]: Programming fields and related flags.

Field Descriptor(40 characters/line) Default Exp.

LINE 1 I hereby approve all charges, and by Enter the message to print on the bottom of integrated the credit card receipt.

LINE 2 signing this document have agreed to the

LINE 3 charges, and full payment of these

LINE 4 charges for which I am billed.

LINE 5

LINE 6

P-MODE:CREDIT CARD AGREEMENT MSG. (CREDIT)

I request that the above cardholder account be credited with the amount shown hereon because of the return of, or adjustments on, the goods, services and/or other items of value originally charged to this account and I authorize the bank to which this credit slip is delivered to charge my account in accordance with my agreement with such bank.XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX

2350REF01 NEC RSenCounter 4000 Reference Manual ◆ 95

Page 104: NEC4000 Programming

P-MODEP-MODE MENU STRUCTURE

GUEST CHECK TRAIL MESSAGE [P7-3-5]

Credit Card Agreement Message [P7-3-4] Programming fields and related flags.

Field Descriptor(40 characters/line) Default Exp.

LINE 1 I request that the above cardholder Enter the message to print on the bottom of the inte-grated credit card refund.LINE 2 account be credited with the amount

LINE 3 shown hereon because of the return of,

LINE 4 or adjustments on, the goods, services

LINE 5 and/or other items of value originally

LINE 6 charged to this account and I authorize

LINE 7 the bank to which this credit slip is

LINE 8 delivered to charge my account in

LINE 9 accordance with my agreement with such

LINE10 bank.

LINE11

LINE12

1P-MODE:GUEST CHECK TRAIL MESSAGE23 XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX4 TIP:_________________________XXXXXXXXXXX5 XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX6 TOTAL:_______________________XXXXXXXXXXX7 XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX8 SIGNATURE:___________________XXXXXXXXXXX9 XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX0 APPROVAL:____________________XXXXXXXXXXX1 XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX2 XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX3 4 5 6 7

96 ◆ NEC RSenCounter 4000 Reference Manual 2350REF01

Page 105: NEC4000 Programming

P-MODEP-MODE MENU STRUCTURE

KITCHEN PRINTER MESSAGE [P7-4]

KITCHEN PRINTER MESSAGE [P7-4-1]

Guest Check Trail Message [P7-3-5]: Programming fields and related flags.

Field Descriptor Default Exp.

LINE 1 Enter the message to print on the bottom of the soft check when SVC-W/TRAIL function code #315 is used.

LINE 2 TIP:_________________________

LINE 3

LINE 4 TOTAL:_______________________

LINE 5

LINE 6 SIGNATURE:___________________

LINE 7

LINE 8 APPROVAL:____________________

LINE 9

LINE10

P-MODE :1 KP HEADER AND FOOTER2 KP GROUP DESCRIPTOR

P-MODE:KP HEADER AND FOOTER

HEADER :WELCOME TO THE NEC RSenCounter 4000!

RESTAURANT SYSTEM XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX

FOOTER :THANK YOU !COME AGAIN.

XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX

2350REF01 NEC RSenCounter 4000 Reference Manual ◆ 97

Page 106: NEC4000 Programming

P-MODEP-MODE MENU STRUCTURE

KP GROUP DESCRIPTOR [P7-4-2]

● 15 KPGs messages per screen.

● Field length is 12 characters per message.

● Maximum of 30 messages.

KP GROUP DESCRIPTOR [P7-4-2-1]

Kitchen printer Message [P7-4-1]: Programming fields and related flags.

Field Descriptor(40 characters/line) Default Explanation

HEADER

LINE # 1 WELCOME TO THE NEC RSenCounter 4000!

Enter KP. header 40 characters x 4 lines

LINE # 2 RESTAURANT SYSTEM

LINE # 3

LINE # 4

FOOTER

LINE # 1 THANK YOU ! Enter KP. footer 40 chrs. x 4 lines.

LINE # 2 COME AGAIN.

LINE # 3

LINE # 4

P-MODE:KP GROUP DESCRIPTOR 1/2# DESCRIPTOR99 ABCDEFGHIJKL

KP Group Descriptor [P7-4-2]: Programming fields and related flags.

Field Descriptor (12 characters/message) Default Explanation

# Enter the message number to access.

DESCRIPTOR

P-MODE:KP GROUP DESCRIPTOR KPG # (1-30) 99 DESCRIPTOR XXXXXXXXXXXX

KP GROUP DESCRIPTOR [P7-4-2-1]: Programming fields and related flags.

Field Descriptor(12 characters/message) Default Explanation

KPG #

DESCRIPTOR Enter the "name" of the Kitchen Printer Groups.

98 ◆ NEC RSenCounter 4000 Reference Manual 2350REF01

Page 107: NEC4000 Programming

P-MODEP-MODE MENU STRUCTURE

REPORT MESSAGE [P7-5]

● 15 messages per screen.

● Field length is 12 characters per message.

● Maximum of 200 messages allocated.

REPORT MESSAGE [P7-5-1]

P-MODE:REPORT MESSAGE Window 1/24# USER DEFINED INTERNAL

999 ABCDEFGHIJKL ABCDEFGHIJKL

Report Message [P7-5]: Programming fields and related flags.

Field Descriptor(12 characters) Default Explanation

# Enter the message number to access.

USER DEFINED "Programmed"

INTERNAL RSenCounter 4000 "Default"

P-MODE:REPORT MESSAGE MESSAGE # (1-350) 999 INTERNAL MSG. XXXXXXXXXXXX USER DEFINED MSG. XXXXXXXXXXXX

Report Message [P7-5-1]: Programming fields and related flags.

Field Descriptor(12 characters) Default Explanation

MESSAGE #

INTERNAL MSG.

USER DEFINED MSG. Default to internal

descriptor

2350REF01 NEC RSenCounter 4000 Reference Manual ◆ 99

Page 108: NEC4000 Programming

P-MODEP-MODE MENU STRUCTURE

Report Message [P7-5-1]: Programming fields and related flags.

# Field Descriptor Used at Length

1 CONSOLIDATED All the 'FROM-TO' range report

2 ALL All the CONSOLIDATED REPORTS for the all stations

3 STATION GRP. All the Station Group Reports

4 RANGE NEW

5 STA# EVERYWHERE 4

6 COUNT FIN, CASHIER, SHIFT,ITE/PLU, NON PROD PLU, PRICE TABLE BY LEVEL, SUB GRP, MAJ GRP, PMIX, COUPON, AT-COMBO

6

7 TOTAL FIN, CASHIER, SHIFT, BUS. FLASH, SALES REP. BY CSHR/SVR, PMIX, MAJ GRP BY SUB GRP, SUB GRP, MAJ GRP, ITEM/PLU NON, NON PROD PLU, PRICE TABLE BY LEVEL, SALES & LABOR%, CASH PULL, SP. ITEM STOCK,

6

8 TBL SERVICE: FIN, CASHIER, SHIFT

9 AVG.$/GUEST FIN, CASHIER, SHIFT, CLOSED TRANS. SUM-MARY

10 AVG.$/CHECK FIN, CASHIER, SHIFT

11 BEGIN CHECK FIN, CASHIER, SHIFT

12 AVG. TIME FIN, CASHIER, SHIFT, DT SERVICE TIME, CLOSED TRANS. SUMMARY

13 SERVICE FIN, CASHIER, SHIFT

14 TRANSFER IN FIN, CASHIER, SHIFT

15 TRANSFER OUT FIN, CASHIER, SHIFT

16 PAID CHECK FIN, CASHIER, SHIFT

17 OPEN CHECKS FIN, CASHIER, SHIFT

18 DPST UNUSED FIN, CASHIER, SHIFT, DRAWER TOTAL, DRAWER A/B

19 SALES : FIN, CASHIER, SHIFT, SALES BY CASHIER, ITEM/PLU SLS VS. COST

20 ITEM SALES FIN, CASHIER, SHIFT

21 PROMO ITEM FIN, CASHIER, SHIFT

22 PROMO SALE FIN, CASHIER, SHIFT

23 NET CPN TL FIN, CASHIER, SHIFT

24 NET AT-COMBO FIN, CASHIER, SHIFT

25 -PLU/ITEM TL FIN, CASHIER, SHIFT

26 ADJUSTED PLU FIN, CASHIER, SHIFT, ITEM/PLU, IITEM SALES VS. COST%, ITEM/PLU VS.COST, NON PROD PLU

27 AT-COMBO TL FIN, CASHIER, SHIFT, AT-COMBO

28 VEND. CPN.TL FIN, CASHIER, SHIFT

29 NET SALES FIN, CASHIER, SHIFT, BUS FLASH, CLOSED TRANS. SUMMARY, STATION

100 ◆ NEC RSenCounter 4000 Reference Manual 2350REF01

Page 109: NEC4000 Programming

P-MODEP-MODE MENU STRUCTURE

30 TAX TOTAL FIN, CASHIER, SHIFT, BUS FLASH, CLOSED TRANS. SUMMARY

31 NON PROD SL FIN, CASHIER, SHIFT, BUS FLASH

32 NON PROD SL2 FIN, CASHIER, SHIFT, BUS FLASH

33 NON PROD SL3 FIN, CASHIER, SHIFT, BUS FLASH

34 GROSS SALES FIN, CASHIER, SHIFT, BUSINESS FLASH, STA-TION

35 YESTERDAY GT FIN, CASHIER, SHIFT

36 GROSS SLS GT FIN, CASHIER, SHIFT

37 SALES RCPTS: FIN, CASHIER, SHIFT

38 G.C. CHANGE FIN, CASHIER, SHIFT

39 GROSS RCPTS FIN, CASHIER, SHIFT

40 GRS CHRG TPS FIN, CASHIER, SHIFT

41 DRAWER: FIN, CASHIER, SHIFT

42 CASH/DRWR TL FIN, CASHIER, SHIFT, DRAWER TOTAL, DRAWER A/B

43 CSH DECLARE FIN, CASHIER, SHIFT

44 OVER/SHORT FIN, CASHIER, SHIFT

45 RECD BY R/A FIN, CASHIER, SHIFT

46 PAID BY P/O FIN, CASHIER, SHIFT

47 CHCK/DRWR TL FIN, CASHIER, SHIFT,DRAWER TOTAL

48 CHK DECLARE FIN, CASHIER, SHIFT

49 CHRG/DRWR TL FIN, CASHIER, SHIFT, DRAWER TOTAL, DRAWER A/B

50 *DRWR TL HM$ FIN, CASHIER, SHIFT

51 RECD ACCT TL FIN, CASHIER, SHIFT, DRAWER TOTAL, DRAWER A/B.

52 PAID OUT TL FIN, CASHIER, SHIFT, DRAWER TOTAL, DRAWER A/B.

53 CASH DEPOSIT Future use

54 CHCK DEPOSIT Future use

55 CHRG DEPOSIT Future use

56 DPST FWRD FIN, CASHIER, SHIFT

57 DRAWER MEMO: FIN, CASHIER, SHIFT

58 TIPS: FIN, CASHIER, SHIFT, (T&A)

59 ACNTBLE SLS FIN, CASHIER, SHIFT

60 EST. TIPS FIN, CASHIER, SHIFT

61 CC TIPS FEE FIN, CASHIER, SHIFT

62 NET CHRG TPS FIN, CASHIER, SHIFT

Report Message [P7-5-1]: Programming fields and related flags.

# Field Descriptor Used at Length

2350REF01 NEC RSenCounter 4000 Reference Manual ◆ 101

Page 110: NEC4000 Programming

P-MODEP-MODE MENU STRUCTURE

63 CASH TIPS FIN, CASHIER, SHIFT

64 TOTAL TIPS FIN, CASHIER, SHIFT

65 TIP % FIN, CASHIER, SHIFT

66 CHRG TPS PAID FIN, CASHIER, SHIFT, DRAWER TOTAL, DRAWER A/B

67 TIPS RCVABLE CASHIER

68 TIPS PAYABLE FIN, CASHIER, SHIFT

69 MEMO: FIN, CASHIER, SHIFT

70 ORDERS FIN, CASHIER, SHIFT, T.P., OPEN TRACK (Not Used), INTERRUPTED ORDER, SALES & LABOR%, BUS FLASH

8

71 NO TAX SLS FIN, CASHIER, SHIFT

72 TX EXMPT SLS FIN, CASHIER, SHIFT

73 TAX 1 SLS FIN, CASHIER, SHIFT

74 TAX 2 SLS FIN, CASHIER, SHIFT

75 TAX 3 SLS FIN, CASHIER, SHIFT

76 TAX 4 SLS FIN, CASHIER, SHIFT

77 TAX 5 SLS FIN, CASHIER, SHIFT

78 TAX 6 SLS FIN, CASHIER, SHIFT

79 GRS CC FEE FIN

80 NET CC FEE FIN

81 SLS & AVGS : FIN, CASHIER, SHIFT

82 AVG.$/ITEM FIN, CASHIER, SHIFT

83 AVG.#ITEM/O FIN, CASHIER, SHIFT

84 AVG.$/ORDER FIN, CASHIER, SHIFT, CLOSED TRANS. SUM-MARY

85 EAT IN SLS FIN, CASHIER, SHIFT, STATION

86 TAKE OUT SLS FIN, CASHIER, SHIFT, STATION

87 TRACK 1 SLS FIN, CASHIER, SHIFT, STATION

88 TRACK 2 SLS FIN, CASHIER, SHIFT, STATION

89 AVG.$/SALE FIN, CASHIER, SHIFT, STATION

90 D. THRU SLS FIN, CASHIER, SHIFT, STATION

91 COUPON TRANS FIN, CASHIER, SHIFT, STAITON

92 AVG.CPN.SLS FIN, CASHIER, SHIFT, STATION

93 COUPON% SLS FIN, CASHIER, SHIFT

94 PRICE CHANGE FIN, CASHIER, SHIFT

95 T. KPG EDIT FIN, CASHIER, SHIFT

96 POWER UP FIN, CASHIER, SHIFT

Report Message [P7-5-1]: Programming fields and related flags.

# Field Descriptor Used at Length

102 ◆ NEC RSenCounter 4000 Reference Manual 2350REF01

Page 111: NEC4000 Programming

P-MODEP-MODE MENU STRUCTURE

97 BALANCING: FIN, CASHIER, SHIFT

98 PROMO TL FIN, CASHIER, SHIFT

99 COUPON TL FIN, CASHIER, SHIFT, DRAWER TOTAL, DRAWER A/B, COUPON

100 DISCOUNT TL FIN, CASHIER, SHIFT, STATION

106 OPEN CS CANC FIN, CASHIER, SHIFT

107 -PLU/ITEM CASHIER

108 NEGATIVE TAX FIN, CASHIER, SHIFT

109 NEGATIVE SLS FIN, CASHIER, SHIFT

110 DAILY GT FIN, CASHIER, SHIFT

111 NON RESET GT FIN, CASHIER, SHIFT

112 TRAINING GT FIN, CASHIER, SHIFT

113 ***BAL TTL 1 FIN, CASHIER, SHIFT

114 ***BAL TTL 2 FIN, CASHIER, SHIFT

115 ***BAL TTL 3 FIN, CASHIER, SHIFT

116 ITEM DISC.TL Cashier

117 ORD. DISC.TL CASHIER

118 SURCHARGE TL CASHIER, BUS FLASH

119 SLS REPORT 1 CASHIER, SALES BY CASHIER

120 SLS REPORT 2 CASHIER, SALES BY CASHIER

121 SLS REPORT 3 CASHIER, SALES BY CASHIER

122 SLS REPORT 4 CASHIER, SALES BY CASHIER

123 SLS REPORT 5 CASHIER, SALES BY CASHIER

124 SLS REPORT 6 CASHIER, SALES BY CASHIER

125 SLS REPORT 7 CASHIER, SALES BY CASHIER

126 SLS REPORT 8 CASHIER, SALES BY CASHIER

127 SLS REPORT 9 CASHIER, SALES BY CASHIER

128 SLS REPT. TL CASHIER

129 CSHR/SVR# SALES REP BY CASHIER/SERVER

130 NAME SALES REP BY COST, T&A 6

131 SALES ITEM/PLU, ITEM SALES VS. COST 8

Report Message [P7-5-1]: Programming fields and related flags.

# Field Descriptor Used at Length

2350REF01 NEC RSenCounter 4000 Reference Manual ◆ 103

Page 112: NEC4000 Programming

P-MODEP-MODE MENU STRUCTURE

132 AVG. PROD PROJ, TIME PERIOD, SALES LABOR%, SALES BY CASHIER

4

133 PERIOD T&A, BUS FLASH 8

134 PREV. GRS GT BUS FLASH

135 RUNNING GT BUS FLASH

136 DESCRIPTOR ITEM/PLU, SUB GRP, MAJ GRP, PRICE TBL BY LEVEL, NON PROD PLU, MAJ GRP BY SUB GRP, ITEM/PLU BY SUB GRP, COUPON, AT-COMBO, ITEM PLU SALES VS. COST, SP ITEM STOCK

137 PLU# ITEM/PLU, NON PROD. PLU, SP. ITEM STOCK 6

138 SOLD ITEM/PLU, PRICE TABLE BY LEVEL, NON PROD PLU

139 +PLU TTL ITEM/PLU, IITEM SALES VS. COST%, ITEM/PLU VS.COST, NON PROD PLU

140 -PLU TTL ITEM/PLU BY SUB GRP

141 SG# ITEM/PLU BY SUB GRP 3

142 PLU DESCR. ITEM/PLU BY SUB GRP

143 COST ITEM SALES VS. COST%, T&A 5

144 +PLU COST ITEM SALES VS. COST%

145 -PLU COST ITEM SALES VS. COST%

146 ADJ.PLU COST ITEM/PLU VS. COST

147 P.TBL# PRICE TBL BY LEVEL 6

148 L# PRICE TBL BY LEVEL 2

149 SUB GRP TTL ITEM/PLU BY SUB GRP,SUB GROUP(SUB GROUP TL?)

150 MG# MAJ GRP BY SUB GRPREP 3

151 MAJ GRP TTL MAJ GRP, T.P. REP BY MAJ GRP

152 PRODUCT PMIX

153 UNIT DESCR. PMIX

154 TIME PMIX, PROD PROJ, T.P., DT SERVICE TIME, OPEN TRACK, INTERRUPTED ORDER,SALES LABOR%, CASH PULL

5

155 UNIT#PC PMIX 8

156 PMX GRP TTL PMIX

157 SORT# COUPON

158 CLU# COUPON

159 AUTO-COMBO# AT-COMBO

160 PROD. PROJ. PROD PROJ

161 WEEK1 PROD PROJ 5

162 WEEK2 PROD PROJ 5

Report Message [P7-5-1]: Programming fields and related flags.

# Field Descriptor Used at Length

104 ◆ NEC RSenCounter 4000 Reference Manual 2350REF01

Page 113: NEC4000 Programming

P-MODEP-MODE MENU STRUCTURE

163 WEEK3 PROD PROJ 5

164 WEEK4 PROD PROJ 5

165 MAJ GRP T.P REP BY MAJ GRP

166 OVER DT SEVICE TIME 4

167 ORDER DT SEVICE TIME 5

168 LINE DT SEVICE TIME 5

169 SERVE DT SEVICE TIME 5

170 TRACK# OPEN TRACK 8

171 #GST OPEN TRACK, CLOSED TRANS. SUMMARY. 4

172 CSHR/SVR OPEN TRACK, CLOSED TRANS. SUMMARY. 8

173 BALANCE OPEN TRACK, INTERRUPTED ORDER 8

174 OPEN ORDERS OPEN TRACK

175 TBL# OPEN TRACK, INTERRUPTED ORDER 4

176 ORD# OPEN TRACK, CLOSED TRANS. SUMMARY. 4

177 TRK#/ORD# INTERRUPTED ORDER 10

178 GRS SLS CLOSED XACTION SUMMARY 8

179 SVC TIME CLOSED TRANS SUMMARY 8

180 TEND.TYPE CLOSED TRANS SUMMARY 10

181 RCPTS CLOSED TRANS SUMMARY 6

182 CHRG TPS CLOSED XACTION SUMMARY 8

183 CASHIER CLOSE XACTION SUMM., CASH PULL 8

184 GRS RCPTS TL CLOSED XACTION SUMMARY

185 GRS SLS TL CLOSED XACTION SUMMARY

186 DRAWER A DRAWER A/B

187 DRAWER B DRAWER A/B

188 EMPL# T&A 5

189 SOC.SEC# T&A 8

190 (JOB) T&A 8

191 TOTAL HOUR NEW

192 REG T&A 4

193 OT T&A 4

194 TIPS NEW 6

195 BRK T&A 4

196 OUT T&A 4

197 HR T&A 3

198 HOLIDAY T&A 7

Report Message [P7-5-1]: Programming fields and related flags.

# Field Descriptor Used at Length

2350REF01 NEC RSenCounter 4000 Reference Manual ◆ 105

Page 114: NEC4000 Programming

P-MODEP-MODE MENU STRUCTURE

199 PREMIUM T&A 7

200 TIPS DECL'D T&A

201 LABOR SALES & LABOR% 12

202 LB/ORDER SALES & LABOR% 8

203 SPMH SALES & LABOR% 6

204 TPMH NEW 6

205 DATE CASHI PULL 6

206 CASH PULL TL CASH PULL

207 STOCK QTY SP. ITEM STOCK

208 OUT? SP. ITEM STOCK 6

209 STOCK VALUE SP. ITEM STOCK

210 Y SP. ITEM STOCK 6

211 M Time keeping 1

212 VAT TOTAL FIN., CASHIER, SHIFT

213 NON PROD TL FIN., CASHIER, SHIFT, BUS FLASH

214 Overwritten LOG PRINTING (RING BUFFER)

215 BY VIDEO

216 CNT

217 PREP.

218 PRI.

219 RUSH

220 CLEARED

221 FULL, Z CTS

350

Report Message [P7-5-1]: Programming fields and related flags.

# Field Descriptor Used at Length

106 ◆ NEC RSenCounter 4000 Reference Manual 2350REF01

Page 115: NEC4000 Programming

P-MODEP-MODE MENU STRUCTURE

MONTH AND DAY MESSAGE [P7-6]

● 15 messages per screen.

● Field length is 6 characters per message.

● Maximum of 30 messages allocated.

MONTH AND DAY MESSAGE [P7-6-1]

P-MODE:MONTH AND DAY MESSAGE Window 1/2# USER DEFINED INTERNAL99 ABCDEF ABCDEF

Month and Day Message [P7-6]: Programming fields and related flags.

Field Descriptor Default Explanation

# Enter the message number to access.

USER DEFINED JAN. – DEC. SUN.-SAT

INTERNAL

P-MODE:MONTH AND DAY MESSAGE MESSAGE # (1-30) 99 INTERNAL MSG. XXXXXX USER DEFINED MSG. XXXXXX

Month and Day Message [P7-6-1]: Programming fields and related flags.

Field Descriptor Default Explanation

MESSAGE #

INTERNAL MSG. JAN. – DEC. SUN.-SAT

USER DEFINED MSG. Default to internal descriptor

2350REF01 NEC RSenCounter 4000 Reference Manual ◆ 107

Page 116: NEC4000 Programming

P-MODEP-MODE MENU STRUCTURE

Month and Day Message [P7-6-1] Programming fields and related flags.

# Field Descriptor Explanation

1 JAN.

2 FEB.

3 MAR.

4 APR.

5 MAY.

6 JUN.

7 JUL.

8 AUG.

9 SEP.

10 OCT.

11 NOV.

12 DEC.

13 SUN.

14 MON.

15 TUE.

16 WED.

17 THU.

18 FRI.

19 SAT.

20

|

30

108 ◆ NEC RSenCounter 4000 Reference Manual 2350REF01

Page 117: NEC4000 Programming

P-MODEP-MODE MENU STRUCTURE

POLE DISPLAY MESSAGE [P7-7]P-MODE:POLE DISPLAY MESSAGE MESSAGE # 1 HOW LONG (SECONDS) 99 LINE 1 XXXXXXXXXXXXXXXXXXXX LINE 2 XXXXXXXXXXXXXXXXXXXX

MESSAGE # 2 HOW LONG (SECONDS) 99 LINE 1 XXXXXXXXXXXXXXXXXXXX LINE 2 XXXXXXXXXXXXXXXXXXXX

Pole Display Message [P7-7]: Programming fields and related flags.

Field Descriptor Default Explanation

MESSAGE 1

HOW LONG (SECONDS) 0 Enter the number of seconds to display message 1 before switching to message 2.

LINE 1-LINE 2 Enter a message to be displayed.

MESSAGE 2

HOW LONG (SECONDS) 00 Enter the number of sec.oncdsto display message 2 before switching to message 2.

LINE 1-LINE 2 Enter a message to be displayed.

2350REF01 NEC RSenCounter 4000 Reference Manual ◆ 109

Page 118: NEC4000 Programming

P-MODEP-MODE MENU STRUCTURE

KEYBOARD SYSTEM [P8]

EDIT FUNCTION KEY FROM KEYBOARD [P8-1]

☞ [1][Enter]

EDIT FUNCTION KEY FROM KEYBOARD [P8-1-1]

Example: If [CASH] Key is pressed [P8-1-1-CASH];

● [EXIT] will bring you back to EDIT FUNCTION KEY FROM KEYBOARD [P8-1].

● [PREV REC] [NEXT REC] will step through other function keys.

P-MODE :KEYBOARD SYSTEM1 EDIT FUNCTION KEY FROM KEYBOARD2 EDIT FUNCTION KEY FROM A LIST3 EDIT MACRO KEY4 TIME ACTIVATE KEYS5 TLU KEYS6 MLU KEYS

P-MODE:EDIT FUNCTION KEY FROM KEYBOARD# DESCRIPTOR INTERNAL NAME9 ABCDEFGHIJKL KEY BRD LVL X

P-MODE :EDIT FUNCTION KEY FROM KEYBOARD# DESCRIPTOR INTERNAL NAME1 BREAK FAST KEY BRD LVL 12 LUNCH KEY BRD LVL 23 DINNER KEY BRD LVL 34 SUN. BRUNCH KEY BRD LVL 45 MANAGER KEY BRD LVL 5

Edit Function Key From Keyboard [P8-1]: Programming fields and related flags.

Field Descriptor(12 characters) Default Explanation

# 1 Keyboard level #

DESCRIPTOR Display user-defined keyboard descriptor in Function key

INTERNAL NAME Internal name of Function key

P-MODE:EDIT FUNCTION KEY FROM KEYBOARD KB LEVEL 1 BREAKFAST

PRESS THE KEY TO BE PROGRAMMED

P-MODE:FUNCTION KEY FUNCTION CODE # 50 INTERNAL NAME CASH DESCRIPTOR CASH TEXT COLOR (0-15) 0 MGR REQUIRED N TAX 123456 Y Y N N N N

110 ◆ NEC RSenCounter 4000 Reference Manual 2350REF01

Page 119: NEC4000 Programming

P-MODEP-MODE MENU STRUCTURE

EDIT FUNCTION KEY FROM A LIST [P8-2]

☞ [50][ENTER] For an example. (CASH)

EDIT FUNCTION KEY FROM A LIST [P8-2-1]

● Refer to the Function key Specification for the rest of function keys.

EDIT MACRO KEY [P8-3]The number of Macro keys is allocatable.

Macro Programming is started by pressing “MACRO SET” and ended with “MACRO SET” key. The first entry of “MACRO SET” key will prompt a user to assign a MACRO Number to hold all the key sequences between the first and the second “MACRO SET” including the Key Lock Switches.The following screen shows how to edit a Macro Key programmed by MACRO SET.

☞ [2][ENTER] or [DOWN ARROW][ENTER] (to edit MACRO #2)

P-MODE:EDIT FUNCTION KEY# USER DEFINED INTERNAL999 ABCDEFGHIJKL ABCDEFGHIJKL

Edit Function Key From a List [P8-2]: Programming fields and related flags.

Field Descriptor(12 characters) Default Explanation

# 1 Enter number to access specific FUNC-TION KEY.

USER DEFINED Programmed descriptor

INTERNAL Default descriptor

P-MODE:FUNCTION KEY FUNCTION CODE # 50 INTERNAL NAME CASH DESCRIPTOR CASH TEXT COLOR (0-15) 0 MGR REQUIRED N TAX 123456 Y Y N N N N

1P-MODE:EDIT MACRO KEY2 # DESCRIPTOR3 99 ABCDEFGHIJKL

Edit Macro Key [P8-3]: Programming fields and related flags.

Field Descriptor Default Explanation

#

DESCRIPTOR

2350REF01 NEC RSenCounter 4000 Reference Manual ◆ 111

Page 120: NEC4000 Programming

P-MODEP-MODE MENU STRUCTURE

MACRO KEY EDIT [P8-3-2]

● 1 CODE # is checked on PLU Validity, other keys will be checked on range. Item #14-#39 will be shown on Row 6-18 of 2/3 and 3/3. Check on the buffer full for maximum of 39 items on “INSERT”

● 2 TYPE selections are shown in COLUMN 43-52

One Macro can hold up to 39 keystrokes excluding [MACRO SET]. Information to be displayed after each key sequence will be;

● Important: Macro set P/R/X/Z/Close will be imposed if there is a change in Mode when key is depressed.[Macro set P] which is associated with the last [MACRO END] will not be recorded as part of the Macro.

P-MODE: EDIT MACRO KEY (1/3) MACRO # 99 1-(Memory Allocation) DESCRIPTOR XXXXXXXXXXXX Line 1-4 display only for

2/3-3/3 MGR REQUIRED Y# TYPE CODE # DESCRIPTOR TYPE 1, 2

1 9 99999999999999 XXXXXXXXXXXXXXXX 1=PLU 2 9 99999999999999 XXXXXXXXXXXXXXXX 2=PLU SFT 3 9 99999999999999 XXXXXXXXXXXXXXXX 3=FUNC 4 9 99999999999999 XXXXXXXXXXXXXXXX 4=MACRO 5 9 99999999999999 XXXXXXXXXXXXXXXX 5=TLU 6 9 99999999999999 XXXXXXXXXXXXXXXX 6=MLU7 9 99999999999999 XXXXXXXXXXXXXXXX 8=INSERT8 9 99999999999999 XXXXXXXXXXXXXXXX 9=DELETE9 9 99999999999999 XXXXXXXXXXXXXXXX 0=IGNORE

10 9 99999999999999 XXXXXXXXXXXXXXXX 11 9 99999999999999 XXXXXXXXXXXXXXXX 12 9 99999999999999 XXXXXXXXXXXXXXXX 13 9 99999999999999 XXXXXXXXXXXXXXXX

Line # :1-39Type of key :PLU/FNC/PLU SHIFT/MLU/TLU/MACROCorresponding CODE# to Type of key pressed.Corresponding Descriptor of a key pressed.

TYPE : 1=PLU2=PLU SFT3=FUNC4=MACRO5=TLU6=MLU8=INSERT9=DELETE0=IGNORE

112 ◆ NEC RSenCounter 4000 Reference Manual 2350REF01

Page 121: NEC4000 Programming

P-MODEP-MODE MENU STRUCTURE

TIME ACTIVATE KEY [P8-4]

● 1 CODE is either MACRO or FUNCTION CODE

● 2 DESCRIPTOR is a USER DEFINED descriptor of Macro or Function key to run.

Edit Macro Key [P8-3-2]: Programming fields and related flags.

Field Descriptor Default Explanation

MACRO #

DESCRIPTOR

MGR REQUIRED N

# LINE # 1-39

TYPE 1

CODE # 0 Corresponding CODE #

Relating to type

P-MODE:TIME ACTIVATE KEY# DESCRIPTOR CODE TYPE 1, 2

99 ABCDEFGHIJKL 123 MACRO 99=1-15, TYPE=MACRO/FUNCTION

Time Activate Key [P8-4]: Programming fields and related flags.

Field Descriptor Default Explanation

#

DESCRIPTOR Display corresponding Code #’s descriptor

CODE

TYPE

2350REF01 NEC RSenCounter 4000 Reference Manual ◆ 113

Page 122: NEC4000 Programming

P-MODEP-MODE MENU STRUCTURE

TIME ACTIVATE KEY [P8-4-1]

Feature to run should be one of FNC or Macro Key Descriptor after CODE # is one from this MACRO 002 as example.

If both FROM and TO time is 00:00, then this period will be ignored (not be checked).

If Station is busy at the time of Time Activated Key is triggered, then it will be ignored, it will not be queued.

TLU KEY PROGRAMMING [P8-5]The number of TLU keys is allocatable.

P-MODE:TIME ACTIVATE KEY TIME ACTIVATE KEY # (1-15) 99 RUN (0=FUNC, 1=MACRO) 9 CODE # 999 (0-350 or 0-Allocation # of

Macro) DESCRIPTOR XXXXXXXXXXXXX

RUN FROM TO SUNDAY Y HH:MM HH:MM MONDAY Y HH:MM HH:MM TUESDAY Y HH:MM HH:MM WEDNESDAY Y HH:MM HH:MM THURSDAY Y HH:MM HH:MM FRIDAY Y HH:MM HH:MM SATURDAY Y HH:MM HH:MM

RUN AT EVERY (0-999) 999 MIN.

Time Activate Key [P8-4-1]: Programming fields and related flags.

Field Descriptor Default Explanation

TIME ACTIVATE KEY # Enter Key Code # to access another key

RUN FUNC Select one to run the below schedule.

CODE # 0 Enter the specific code# to run.

DESCRIPTOR Display corresponding Code #’s descrip-tor

RUN

FROM 99:99 Header to show starting time

TO 99:99 Header to show ending time.

RUN AT EVERY 99 MIN. 0 0=activated only once at FROM time.

P-MODE:TLU KEY # DESCRIPTOR

999 ABCDEFGHIJKL

TLU Key Programming [P8-5]: Programming fields and related flags.

Field Descriptor Default Explanation

# ‘TLU 1’ to the 1st. Rec. Enter number to access specific TLU

DESCRIPTOR TLU’s descriptor

114 ◆ NEC RSenCounter 4000 Reference Manual 2350REF01

Page 123: NEC4000 Programming

P-MODEP-MODE MENU STRUCTURE

TLU KEY PROGRAMMING [P8-5-1]

● 1 Item #10-#18 will be shown on Row 8-16 of 2/2

● 2 TYPE selections are shown in COLUMN 43-52

One TLU can hold up to 18 ITEMs.Information to be displayed after each key sequence will be;

MLU KEY PROGRAMMING [P8-6]# of MLU keys is allocatable.

P-MODE:TLU KEY PROGRAMMING 1/2 TLU # 999 0-(Memory Allocation) DESCRIPTOR XXXXXXXXXXXX MGR REQUIRED Y BACK GROUND COLOR (0-15) 99

# TYPE CODE # DESCRIPTOR TYPE 1, 2

1 9 99999999999999 XXXXXXXXXXXXXXXX 1=PLU2 9 99999999999999 XXXXXXXXXXXXXXXX 2=PLU SFT 3 9 99999999999999 XXXXXXXXXXXXXXXX 3=FUNC 4 9 99999999999999 XXXXXXXXXXXXXXXX 4=MACRO 5 9 99999999999999 XXXXXXXXXXXXXXXX 5=TLU 6 9 99999999999999 XXXXXXXXXXXXXXXX 6=MLU7 9 99999999999999 XXXXXXXXXXXXXXXX8 9 99999999999999 XXXXXXXXXXXXXXXX9 9 99999999999999 XXXXXXXXXXXXXXXX 0=IGNORE

Line # :1-18Type of key :PLU/FNC/PLU SHIFT/MLU/TLU/MACRO/ALPHACorresponding CODE# to Type of key pressed.Corresponding Descriptor of a key pressed.

TLU Key Programming [P8-5-1]: Programming fields and related flags.

Field Descriptor Default Explanation

TLU # Enter number to access another TLU

DESCRIPTOR Descriptor of this TLU.

MGR REQUIRED N

TYPE 0 Select one of them from the list.

CODE # 0 Corresponding Key code.

BACK GROUND COLOR Select the color for this table from the color pallet list.

P-MODE:MLU KEY # DESCRIPTOR

999 ABCDEFGHIJKL

MLU Key Programming [P8-6]: Programming fields and related flags.

Field Descriptor Default Explanation

# Enter number to access specific MLU

DESCRIPTOR MLU’s Descriptor

2350REF01 NEC RSenCounter 4000 Reference Manual ◆ 115

Page 124: NEC4000 Programming

P-MODEP-MODE MENU STRUCTURE

MLU KEY PROGRAMMING [P8-6-1]P-MODE:MLU KEY PROGRAMMING MLU # 999 0-(Memory Allocation) DESCRIPTOR XXXXXXXXXXXX MGR REQUIRED Y POP UP AFTER SELECTION Y BACK GROUND COLOR (0-15) 99

MLU Key Programming [P8-6-1]: Programming fields and related flags.

Field Descriptor Default Explanation

MLU # Enter number to access another MLU

DESCRIPTOR ‘MLU 1’ to only 1st. Rec.

Descriptor of this MLU.

MGR REQUIRED N

POP UP AFTER SELECTION N If Y, then this MLU will be called again after selection and EXIT will make disap-pear this MLU, however the PLU selected has a table linked, then exit MLU window and display linked table.

BACK GROUND COLOR 0 Select the background color for this MLU table from the pallet list.

116 ◆ NEC RSenCounter 4000 Reference Manual 2350REF01

Page 125: NEC4000 Programming

P-MODEP-MODE MENU STRUCTURE

COUPON AND AUTO-COMBO [P9]

COUPON AND AUTO-COMBO OPTION [P9-1]

P-MODE :COUPON AND AUTO-COMBO1 COUPON AND AUTO-COMBO OPTION2 COUPON3 AUTO-COMBO

P-MODE:COUPON AND AUTO-COMBO OPTION ENABLE AUTO-COMBO Y ALLOW CPN. OR ITEM DISC. ON AUTO-COMBO Y

Coupon and Auto-Combo Option [P9-1]: Programming fields and explanations

Field Descriptor Default Explanation

ENABLE AUTO-COMBO N IF = Y, then • Upon SUBTOTAL or DESTINATION key

entry, the system looks for all AUTO-COMBOs with “AT SUBTOTAL”.[1-28][AUTO-COMBO] is also allowed to apply a certain AUTO-COMBO if this AUTO-COMBO is selected MANUALLY. If AUTO-COMBO entered manually is set to DISABLED, then Error Message “DIS-ABLED”If there is no match found on AUTO-COMBO by manual key entry or SUBTO-TAL KEY, then Error Message “ NO MATCH”

• If AUTO-COMBO is set to INDIVIDUAL, then this AUTO-COMBO only run by [1-28][AUTO-COMBO].

• If AUTO-COMBO is set to DISABLED, then this AUTO-COMBO will not be run at all.

[PLU][PLU]SBTL (search, and apply AUTO-COMBO, or Error Message NO MATCH)[PLU][PLU]SBTL (search, and apply AUTO-COMBO, or Error Message NO MATCH)

ALLOW CPN. OR ITEM DISC. ON AUTO-COMBO

N ALLOW COUPON OR ITEM DISCOUNT ON AUTO-COMBO Y/N = N • IF = NO, then AUTO-COMBO will not be

given to the items to which a COUPON or ITEM DISCOUNT is already applied to, or vice versa.

• If = Y, then this may not give a practical result.

It does not allow both coupon and item discount on the same item.

2350REF01 NEC RSenCounter 4000 Reference Manual ◆ 117

Page 126: NEC4000 Programming

P-MODEP-MODE MENU STRUCTURE

COUPON [P9-2]

COUPON [P9-2-1]

P-MODE:COUPON# DESCRIPTOR CLU #

999 ABCDEFGHIJKLMNOP 12345678901234

Coupon [P9-2]: Programming fields and explanations

Field Descriptor Default Explanation

# 1 Physical Mem. #

DESCRIPTOR 1stRec.=‘COU-PON 1’

CPN DESCRIPTOR

CLU# Coupon Look Up Number

P-MODE:COUPON (1/2)# 999 1-(Memory Allocation)CLU # 99999999999999DESCRIPTOR (12th.=^) XXXXXXXXXXXXXXXXTEXT COLOR ^ 99ACTIVE YMGR REQUIRED YTAX 123456 Y Y Y Y Y YEXCLUSIVE YREPEATABLE # (0-99) 99NET ITEMS YACTION (0=$OFF, 1 =%OFF, 2=REPLACE, 3=OPEN$, 4=OPEN%, 5=2nd.EOL)

9

%OFF/2nd.EOL/OPEN% HALO 999.99 MAX.CPN. AMT. ALLOWED XXX9999999.99 XXX= System

Currency Mark $OFF/REPLACE/OPEN$ HALO XXX999999.99MIN. PURCHASE REQUIRED XXX9999999.99SORT # (1-99) 99

118 ◆ NEC RSenCounter 4000 Reference Manual 2350REF01

Page 127: NEC4000 Programming

P-MODEP-MODE MENU STRUCTURE

● *7 = Type Selections are shown on Col. 43-52

● *9 = Show “NET” on the first item, if ACTION=0, 2, or 3, NET=Y, AND SELECT=ALL

● *10 = Available Type and Line are only DC and Line 7 only, if ACTION=Second EOL

Coupon [P9-2-1]: Programming fields and explanations (page 1)

Field Descriptor Default Explanation

# 1 Physical Mem. #

CLU# 0 Coupon Look Up Number

DESCRIPTOR 1stRec.=‘COU-PON 1’

CPN DESCRIPTOR - 12 characters

TEXT COLOR 15 Color palette, 0-15

ACTIVE N INACTIVE

MGR REQUIRED N Requires a manager to process this coupon

TAX123456 NNNNNN

EXCLUSIVE Y If =Y, then this coupon can not be entered if another coupon has been previously entered or this coupon has been entered previously, then another coupon can not be entered.

REPEATABLE # 0 The maximum number of times this coupon can be executed by one coupon tendering.

NET ITEMS Y Reflect CPN.$ on items. See details.

● If either FROM or TO Date is 00/00/0000, then this coupon becomes inactive.

● If both FROM and TO time is 00:00, then this period will be ignored.

P-MODE:COUPON 2/2 # 999 CLU # 99999999999999 DESCRIPTOR XXXXXXXXXXXXXXXX SELECT (0=ALL,1=ANY) 9

TYPE PLU/DC # DESCRIPTOR QTY NET 9 99999999999999 XXXXXXXXXXXXXXXX 99 TYPE *7,9,10

9 99999999999999 XXXXXXXXXXXXXXXX 99 1=PLU9 99999999999999 XXXXXXXXXXXXXXXX 99 2=DC9 99999999999999 XXXXXXXXXXXXXXXX 99 0=Delete9 99999999999999 XXXXXXXXXXXXXXXX 99

DATES (0=ALL,1=PERIOD) 9 If DATES=1PERIOD FROM MM/DD/YYYY TO MM/DD/YYYY

DAYS (0=ALL,1=SELECT) 9

SELECT SUN MON TUE WED THU FRI SATY Y Y Y Y Y Y

TIME FROM HH:MM TO HH:MM

2350REF01 NEC RSenCounter 4000 Reference Manual ◆ 119

Page 128: NEC4000 Programming

P-MODEP-MODE MENU STRUCTURE

ACTION : 0 How the coupon will "act".

% OFF/2ND.EOL/OPEN% HALO 0 Coupon % If OPEN 5, then interpreted as HALO for entry.

MAX. CPN. AMT. ALLOWED 0 Accept %OFF /OPEN%/2nd. EOL, and ACTION:NET ITEM = NO

$ OFF/REPLACE/OPEN$ HALO 0 Coupon value or Base Price to calculate Coupon Value.If OPEN $, then interpreted as HALO

MIN. PURCHASE REQUIRED 0 Minimum Purchase Amount per sales trans-action required for this coupon to be accepted. This amount will not include TAX.

SORT # 1 Used in report

SELECT 0 ALL = needs all the items and QTY. speci-fied in the list.ANY = one of any items and QTY. specified in the list.

TYPE 0

PLU/DC # 0 PLU or Discount Category

DESCRIPTOR Corresponding Descriptor of above item.

QTY 0 Quantity required for this Item.

DATES 0 If ALL, this coupon is always accepted if it is not Inactive.

PERIOD FROM 00/00/0000 Available when DATES=1

TO 00/00/0000 Available when DATES=1

DAYS 0

SELECT SUN-SAT N Available when DAY=1

TIME

FROM 00:00

TO 23:59

Coupon [P9-2-1]: Programming fields and explanations (page 1)

Field Descriptor Default Explanation

120 ◆ NEC RSenCounter 4000 Reference Manual 2350REF01

Page 129: NEC4000 Programming

P-MODEP-MODE MENU STRUCTURE

1) CASE IF ACTION = $ OFFMAX.CPN.$99999.99 is disabled if NET ITEMS = Y, 2ND.EOL, REPLACE, $ OFF, or OPEN $ is selected.

If SELECT =ALL and NET=Y, then display (NET) on the right of QTY of the first item.

2) CASE IF ACTION = % OFFMAX.CPN.$99999.99 is disabled if NET ITEMS = Y, 2ND.EOL, REPLACE, $ OFF, or OPEN $ is selected.

3) CASE IF ACTION = REPLACE MAX.CPN.$99999.99 is disabled if NET ITEMS = Y, 2ND.EOL, REPLACE, $ OFF, or open $ is selected.

If SELECT =ALL and NET=Y, then display (NET) on the right of QTY of the first item.

4) CASE IF ACTION = 2ND.EOLMAX.CPN.$99999.99 is disabled if NET ITEMS = Y, 2ND.EOL, REPLACE, $ OFF, or open $ is selected.

*1 SELECT will default to “ANY” and List only accept one Line with Quantity greater than 1.

CPN.$ = 2ND. Equal or Lesser Value x % set in the above screen.

Example:Second EOL by 100% : Apply a coupon to the second same item or lesser item that matches the defi-nition. For buy 1, get 1 free, then the higher priced item is charged, and the lower item is replaced with FREE from its descriptor.

Applied to the second highest price item in SUB Discount Category that matches the coupon defini-tion.

5) CASE IF ACTION = OPEN $MAX.CPN.$99999.99 is disabled if NET ITEMS = Y, 2ND.EOL, REPLACE, $ OFF, or OPEN $ is set.Action Open $ amount field is interpreted as HALO $ for entry.

If SELECT =ALL and NET=Y, then display (NET) on the right of QTY of the first item.

● SELECT =ALLIF NET = Y, then the first item will be netted.Display (NET) on the first item.

● SELECT =ANYIF NET = Y, then the first applicable item will be netted.

6) CASE IF ACTION = OPEN % MAX.CPN.$99999.99 is disabled if NET ITEMS = Y, 2ND.EOL, REPLACE, $ OFF, or OPEN $ is set.

Action Open % field is interpreted as HALO %

ORDER: SUB 2.19SUB 1.99 This becomes FreeCOKE .99FREE -1.99Total 3.18

$999999.99

% 999.99

2350REF01 NEC RSenCounter 4000 Reference Manual ◆ 121

Page 130: NEC4000 Programming

P-MODEP-MODE MENU STRUCTURE

AUTO COMBO PROGRAMMING [P9-3]

● A maximum of 30 AUTO-COMBOs (Mem. Alloc.) are available. (2 Pages)

☞ [ENTER]

AUTO COMBO PROGRAMMING [P9-3-1]

PAGE (1/2)

● *1 Limit DESCRIPTOR to 10 characters and display only

● *23 Type Selection is shown on Col.43-52

● *3 PRICE/@ fields are only available in METHOD = REPLACE

P-MODE:AUTO-COMBO# DESCRIPTOR RUN99 ABCDEFGHIJKLMNOP AT SUBTOTAL

Auto-Combo [P9-3]

Field Descriptor Default Explanation

# 1 Physical Mem. #

DESCRIPTOR 1stRec.=‘COUPON 1’ CPN DESCRIPTOR

RUN MANUALLY Select Disabled, At Subtotal, or Manually

P-MODE:AUTO COMBO PROGRAMMING (1/2) AUTO-COMBO # (1-30) 99 DESCRIPTOR ( XXXXXXXXXXXXXXXX TEXT COLOR 99

TYPE PLU/DC # DESCR. QTY PRICE/@ 9 99999999999999 XXXXXXXXXX 99 999999.99 TYPE *1, 2, 3 9 99999999999999 XXXXXXXXXX 99 999999.99 1=PLU 9 99999999999999 XXXXXXXXXX 99 999999.99 2=DC 9 99999999999999 XXXXXXXXXX 99 999999.99 0=DELETE 9 99999999999999 XXXXXXXXXX 99 999999.99 AUTO-COMBO VALUE 9999999.99 This shows a sum of

each line of QTY x PRICE/@

RUN (0=DISABLED,1=AT SBTL,2=MANUALLY) 9

● If either FROM or TO Date is 00/00/0000, then this coupon becomes inactive.

● If both FROM and TO time is 00:00, then this period will be ignored.

P-MODE:AUTO COMBO PROGRAMMING (2/2)AUTO-COMBO # 99DESCRIPTOR XXXXXXXXXXXXXXXX

DATES (0=ALL,1=PERIOD) 9 If DATES=1PERIOD: FROM MM/DD/YYYY

TO MM/DD/YYYY DAYS (0=ALL,1=SELECT) 9 If DATES=1

SELECT: SUN MON TUE WED THU FRI SATY Y Y Y Y Y Y

TIME FROM HH:MM TO HH:MM

122 ◆ NEC RSenCounter 4000 Reference Manual 2350REF01

Page 131: NEC4000 Programming

P-MODEP-MODE MENU STRUCTURE

Auto-Combo [P9-3-1]: Page 1/2

AUTO-COMBO # 1

DESCRIPTOR 1st. Rec. =‘AUTO COMBO 1’

Descriptor of this Auto-Combo

TEXT COLOR 15 Color of coupon

TYPE 0

PLU/DC # 0

DESCR. 12 char Corresponding Descriptor of above item.

QTY 0 Quantity required for this item.

PRICE/@ This is only available when METHOD = 0

AUTO-COMBO VALUE Sum of items above.

RUN MANUALLY Select Disabled, At Subtotal, or Manually

Auto-Combo [P9-3-1]: Page 2/2

Field Descriptor Default Explanation

AUTO-COMBO # 1

DESCRIPTOR 1st. Rec. =‘AUTO COMBO 1’

Descriptor of this Auto-Combo

DATES 0 If ALL, this coupon is always accepted if it is not Inactive.

PERIOD FROM 00/00/0000 Available when DATES=1

TO 00/00/0000 Available when DATES=1

DAYS 0

SELECT SUN-SAT N Available when DAY=1

TIME

FROM 00:00

TO 23:59

2350REF01 NEC RSenCounter 4000 Reference Manual ◆ 123

Page 132: NEC4000 Programming

P-MODEP-MODE MENU STRUCTURE

HUMAN RESOURCES [P10]

EMPLOYEE FILE [P10-1]Allocatable up to 999 employees.

☞ [1]ENTER

P-MODE :HUMAN RESOURCES1 EMPLOYEE FILE2 TIME & ATTENDANCE3 JOB CODE TABLE4 PAY RATE TABLE5 AUTHORITY LEVELS6 PRINT EMPLOYEE LIST

P-MODE:EMPLOYEE FILE# NAME STATUS999 ABCDEFGHIJKL ACTIVE STATUS=ACTIVE/INACT.

P-MODE :EMPLOYEE FILE# NAME STATUS001 ZACHARY ACTIVE002 ANNIE ACTIVE003 ETHAN ACTIVE004 SAM ACTIVE005 HANK ACTIVE006 WILLIE INACTIVE007 CARTER INACTIVE

Employee File [P10-1]: Programming fields and related flags.

Field Descriptor Default Explanation

# Employee file #

NAME ‘EMPLOYEE 1’ for the 1st. Rec.

Employee name

STATUS ACTIVE ACTIVE or INACTIVE

124 ◆ NEC RSenCounter 4000 Reference Manual 2350REF01

Page 133: NEC4000 Programming

P-MODEP-MODE MENU STRUCTURE

EMPLOYEE FILE [P10-1-1/999]

● *1 Check on duplication and # is in Memory allocation

● *2 XXX=System Currency Mark, Available fields are Code field only.

● KEY CODE field will accept Employee card swipe if MCR is available.

P-MODE:EMPLOYEE FILE (1/2)# 999 1-Mem. Alloc.EMPLOYEE NAME XXXXXXXXXXXXACTIVE YBIRTH DATE MM/DD/YYYYCSHR/SVR # 999 1-Mem. Alloc.SS # 9999999999KEY CODE 9999999999PHONE # 9999999999AUTHORITY LEVEL (1-30) 99

#

JOB CODE

RATE CODE

1

01 XXXXXXXXXXXX 99 XXX9999.99 *2

2

01 XXXXXXXXXXXX 99 XXX9999.99 *2

3

01 XXXXXXXXXXXX 99 XXX9999.99 *2

4

01 XXXXXXXXXXXX 99 XXX9999.99 *2

P-MODE:EMPLOYEE FILE (2/2) # 999 EMPLOYEE NAME XXXXXXXXXXXX COMPUL. TIP ENTRY AT CLOCK OUT Y COMPUL. JOB CODE ENTRY AT CLOCK IN Y ELIGIBLE FOR HOLIDAY PAY Y

Employee File [P10-1-1]: Programming fields and related flags.

# Employee file #

EMPLOYEE NAME ‘EMPLOYEE 1’ for the 1st. Rec.

Employee name

ACTIVE Y

BIRTH DATE 00/00/0000

CLASS 0

CSHR/SVR # 0

SS # 0 Social Security Number

KEY CODE 1 Sign on Key Code

PHONE # 0 Phone number

AUTHORITY LEVEL (1-30) 1

JOB CODE “1” for the 1st. Rec.

Pick from the list

RATE CODE “1” for the 1st. Rec.

Pick from the list

2350REF01 NEC RSenCounter 4000 Reference Manual ◆ 125

Page 134: NEC4000 Programming

P-MODEP-MODE MENU STRUCTURE

TIME & ATTENDANCE [P10-2]

GLOBAL OPTIONS [P10-2-1]

● “PAY PERIOD DATES: TO MM/DD/YYYY”The date programmed here is used in X/Z mode Time and Attendance Screen.The date for the new period will be prompted at Z2 Time Keeping Period.

Employee File [P10-1-1]: Programming fields and related flags.

Field Descriptor Default Explanation

Record: Page 2/2

# Employee file #

EMPLOYEE NAME ‘EMPLOYEE 1’ for the 1st. Rec.

Employee name

COMPUL. TIP ENTRY AT CLOCK OUT

N Prompt for TIP entry at clock out.

COMPUL. JOB CODE ENTRY AT CLOCK IN

N If Y, must enter job code at clock in.

ELIGIBLE FOR HOLIDAY PAY N

P-MODE :HUMAN RESOURCES-TIME & ATTENDANCE1 GLOBAL OPTIONS2 HOLIDAY PAY PROGRAMMING3 PREMIUM HOUR PAY PROGRAMMING4 MINOR WORKING HOUR DEFINITION 15 MINOR WORKING HOUR DEFINITION 2

P-MODE:GLOBAL OPTIONS BREAKS (0=DISABLED,1=PAID,3=UNPAID) 9 AUTO RE-CLOCK-IN AT TIME KEEPING Z1 Y # OF LAST DIGITS OF KEY CODE (0-10) 99 TIP REPORTING % OF SALES 99.99 OVERTIME BASIS (0=DAILY,1=WEEKLY) 9 AT FACTOR OF 9.99 OVERTIME STARTS FROM : If TO Date is 00/00/0000,

then no “PAY PERIOD CLOSING DATE ” on screen at TK Z1/Z2/X.

DAY (HOURS) 99 WEEK (HOURS) 99 PAY PERIOD 9 (0=NO,1=WK,2=BI-WK,3=SEMI-MO.,4=MO.) 9

TO MM/DD/YYYY S-Mode:Mem Allocate. LABOR WEEK BEGINS ON 9 If PAY PERIOD=WK or

BI-WK, then day of “TO MM/DD/YYYY” and LABOR WEEK BEGINS ON has to be synchronized.

(0=SU,1=M,2=T,3=W,4=T,5=F,6=SA)

MINIMUM BREAK PERIOD (0-255) 999

126 ◆ NEC RSenCounter 4000 Reference Manual 2350REF01

Page 135: NEC4000 Programming

P-MODEP-MODE MENU STRUCTURE

HOLIDAY PAY PROGRAMMING [P10-2-2]

☞ [1][ENTER] or [ENTER]

Global Options [P10-2-1]: Programming fields and related flags.

Field Descriptor Default Explanation

BREAKS 1 DISABLED will only allow to select “OUT” and treated as PAID Breaks.

AUTO RE-CLOCK-IN AT TIME KEEPING Z1

Y If=Y, Z1 will clock back in active employees.

# OF LAST DIGITS OF KEY CODE

1

TIP REPORTING% OF SALES 0

OVERTIME BASIS :

1

AT FACTOR OF 0.0

OVERTIME STARTS FROM;

DAY (HOURS) 0.0

WEEK (HOURS) 0.0

PAY PERIOD Use Selection made in S-Mode Memory allocation. You cannot change selection here. This displays what is set in S-mode.

TO 00/00/0000 Enter the date for the last date of the PAY PERIOD.

LABOR WEEK BEGINS 0 Selection from the list.

MINIMUM BREAK PERIOD (0-255)

0 Requires an employee to be clocked out for a required time in minutes.

P-MODE:HOLIDAY PAY Page 1/2# DESCRIPTOR HOLIDAY Time 99 ABCDEFGHIJKL MM/DD/YY 99:99-99:99 99=1-15

P-MODE :HOLIDAY PAY# DESCRIPTOR HOLIDAY TIME99 ABVDEFGHIJKL MM/DD/YY 99:99-99:991 N.YEAR’S EVE 12/31/99 16:00 - 24:002 N.YEAR’S DAY 01/01/00 00:00 - 24:003 PRSDN’T DAY 02/10/00 00:00 - 23:59

2350REF01 NEC RSenCounter 4000 Reference Manual ◆ 127

Page 136: NEC4000 Programming

P-MODEP-MODE MENU STRUCTURE

HOLIDAY PAY PROGRAMMING [P10-2-2-1]

● *1 No duplicate date registration is allowed.

● *2 24:00 equals 23:59:59

● If Date is 00/00/0000, then this date is not considered as a holiday

● If both FROM and TO times are 00:00, then this time period will not be checked.

JOB CODE TABLE [P10-3]4 Pages (30 Job Codes) PAGE 1/2

● *1 IN LABOR CALC. =INCLUDED IN LABOR CALCULATION

☞ [ENTER]

P-MODE:HOLIDAY PAY PROGRAMMING# 99HOLIDAY NAME XXXXXXXXXXXXDATE MM/DD/YYYYAPPLICABLE TIME : FROM HH:MM TO HH:MMHOLIDAY FACTOR 99.99

P-MODE:JOB CODE TABLE# DESCRIPTOR IN LABOR CALC. AUTH.# *1 99 ABCDEFGHIJKL YES 99 99=1-30

P-MODE :JOB CODE TABLE# DESCRIPTOR IN LABOR CALC. AUTH.#01 JOB 1 YES 102 SERVER YES 203 SHIFT MGR NO 104 CASHIER 1 YES 205 CASHIER 2 YES 30

P-MODE :JOB CODE TABLE# DESCRIPTOR IN LABOR CALC.16 JOB 2 YES AUTH.#17 SERVER X YES 7| 10|30 TRAINING NO 0

Job Code Table [P10-3]: Programming fields and related flags.

Field Descriptor Default Explanation

#

DESCRIPTOR ‘JOB 1’ to the 1st. Rec.30th Recs. holds “TRAINING”

IN LABOR CALC. Y If=Y, then this job code will be included in the sales labor % Rep.

128 ◆ NEC RSenCounter 4000 Reference Manual 2350REF01

Page 137: NEC4000 Programming

P-MODEP-MODE MENU STRUCTURE

JOB CODE TABLE [P10-3-1]

PAY RATE TABLE [P10-4]4 Pages (15 PAY RATES x 4=60)

Page 1/4 to 4/4 page

☞ [1][ENTER] or [ENTER]

P-MODE:JOB CODE TABLE JOB CODE # (1-30) 99 DESCRIPTOR XXXXXXXXXXXX INCLUDE IN SALES LABOR CALCULATION Y AUTHORITY LEVEL (0-30) 0

Job Code Table [P10-3-1]: Programming fields and related flags.

Field Descriptor Default Explanation

JOB CODE #

DESCRIPTOR ‘JOB 1’ to the 1st. Rec.

30th Recs. holds “TRAINING”

12 characters

INCLUDE IN SALES LABOR CALCULATION

Y If=Y, then this job code will be included in the sales labor % Rep.

AUTHORITY # 1 When an employee clocks in at the time clock, a new authority level will depend on the Job Code Authorization number.

P-MODE:PAY RATE TABLE# DESCRIPTOR RATE/HOUR99 ABCDEFGHIJKL $$$9999.99 99=1-60

P-MODE :PAY RATE TABLE# DESCRIPTOR RATE/HOUR.01 JOB 1 $ 6.5002 SERVER $ 7.0003 SHIFT MGR $ 15.0004 CASHIER 1 $ 12.0005 CASHIER 2 $ 12.50

Pay Rate Table [P10-4]: Programming fields and related flags.

Field Descriptor Default Explanation

#

DESCRIPTOR ‘PAY RATE 1’ to the 1st. Rec.

RATE/HOUR

2350REF01 NEC RSenCounter 4000 Reference Manual ◆ 129

Page 138: NEC4000 Programming

P-MODEP-MODE MENU STRUCTURE

PAY RATE TABLE [P10-4-1/60]

AUTHORITY LEVEL [P10-5](2x15=30 levels) Page 1/2

☞ [ENTER]

P-MODE:PAY RATE TABLE. PAY RATE # (1-60) 99 DESCRIPTOR XXXXXXXXXXXX PAY RATE PER HOUR XXX9999.99 XXX=System Currency

Mark

Pay Rate Table [P10-4-1]: Programming fields and related flags.

Field Descriptor Default Explanation

PAY RATE #

DESCRIPTOR ‘PAY RATE 1’ to the 1st. Rec.

PAY RATE PER HOUR $6 to the 1st. Rec.The rest is

$0.0

Currency descriptor

P-MODE:AUTHORITY LEVEL# DESCRIPTOR99 ABCDEFGHIJKL

P-MODE :AUTHORITY LEVEL# DESCRIPTOR01 STORE OWNER02 STORE MGR.03 SHIFT MGR.04 CASHIER05 SERVER

Authority Level [P10-5]: Programming fields and related flags. 1/3

Field Descriptor DefaultAuth. 1

Default for Auth. 2-30 Explanation

# 1

DESCRIPTOR MANAGER

130 ◆ NEC RSenCounter 4000 Reference Manual 2350REF01

Page 139: NEC4000 Programming

P-MODEP-MODE MENU STRUCTURE

Authority Level [P10-5-1]

GLOBAL [P10-5-1-1]

● *1 If = Y, then this will allow to perform function keys set MGR.=Y without going to X-Mode.

X-MODE EDIT [P10-5-1-2]

P-MODE EDIT [P10-5-1-3]

P-MODE EDIT - EMPLOYEE [P10-5-1-4]

P-MODE :AUTHORITY LEVEL-STORE OWNER1 GLOBAL2 X-MODE EDIT3 P-MODE EDIT - PLU4 P-MODE EDIT - EMPLOYEE5 P-MODE EDIT - MISCELLANEOUS6 TRANSACTION7 TABLE SERVICE OPERATION8 TIME CLOCK9 REPORT10 CREDIT CARD

P-MODE:AUTHORITY LEVEL-GLOBAL AUTH. LEVEL # (1-30) 99 DESCRIPTOR XXXXXXXXXXXX ALLOW ADJUST CLOSED CHECK TENDER Y ALLOW MANAGER REQUIRED FUNCTION Y *1 ALWAYS OPEN DRAWER (0=NONE,1=A,2=B) 9

P-MODE:AUTHORITY LEVEL-X-MODE EDIT AUTH. LEVEL # 99 DESCRIPTOR XXXXXXXXXXXX ALLOW CASH/CHECK DECLARATION Y ALLOW KEYBOARD, PRICE, & KP LEVEL SET Y ALLOW TIME CLOCK EDIT Y ALLOW DRAWER ASSIGN Y ALLOW SYSTEM STATUS TABLE EDIT Y ALLOW FILE MAINTANANCE Y

P-MODE:AUTHORITY LEVEL-P-MODE EDIT-PLU AUTH. LEVEL # 99 DESCRIPTOR XXXXXXXXXXXX ALLOW PLU/PLU PPTY EDIT Y ALLOW ONLY PLU PRICE EDIT Y ALLOW COND./TLU/MLU/L. PLU TBL EDIT Y

P-MODE:AUTHORITY LEVEL-P-MODE EDIT-EMPLOYEE AUTH. LEVEL # 99 DESCRIPTOR XXXXXXXXXXXX ALLOW AUTHORITY LEVEL EDIT Y ALLOW EMPLOYEE FILE EDIT Y ALLOW JOB CODE EDIT Y ALLOW PAY RATE EDIT Y ALLOW H. RESOURCE OPTION FLAGS EDIT Y

2350REF01 NEC RSenCounter 4000 Reference Manual ◆ 131

Page 140: NEC4000 Programming

P-MODEP-MODE MENU STRUCTURE

P-MODE EDIT - MISCELLANEOUS [P10-5-1-5]

TRANSACTION [P10-5-1-6]

TABLE SERVICE OPERATION [P10-5-1-7]

TIME CLOCK [P10-5-1-8]

P-MODE:AUTHORITY LEVEL-P-MODE EDIT-MISCELLANEOUS AUTH. LEVEL # 99 DESCRIPTOR XXXXXXXXXXXX ALLOW EDIT SYSTEM CONFIGURATION EDIT Y ALLOW SYSTEM OPTION EDIT Y ALLOW FUNCTION KEY EDIT Y ALLOW CPN. AND AUTO-COMBO OPTION EDIT Y ALLOW ALL OTHER P-MODE EDITS Y

P-MODE:AUTHORITY LEVEL-TRANSACTION AUTH. LEVEL # 99 DESCRIPTOR XXXXXXXXXXXX DEFAULT KEYBOARD LEVEL (0,1,2,3,4,5) 9 ALLOW DESTINATION CHANGE Y ALLOW PRICE TABLE OVER-RIDE Y ALLOW PLU PRICE OVER-RIDE Y ALLOW NO SALE,R/A & P/O Y ENABLE OPERATOR / CLERK INTERRUPT Y ALLOW CANC. OF DT Q’D ORDER IN X MODE Y

P-MODE:AUTHORITY LEVEL-T.S. OPERATION AUTH. LEVEL # 99 DESCRIPTOR XXXXXXXXXXXX ENFORCE CHECK CREATION Y ENFORCE SEAT# ENTRY FOR EACH ITEM Y ALLOW CANCEL AFTER RECALL Y ALLOW VOIDS OF SERVICED ITEMS Y ALLOW EDIT ANY SOFT CHECKS Y ALLOW COMBINE OWN SOFT CHECKS Y ALLOW COMBINE ANY SOFT CHECKS Y ALLOW TRANSFER OF CHECKS Y ALLOW TABLE# CHANGE IN R-MODE Y ALLOW PAYMENT OF OWN SOFT CHECKS Y ALLOW PAYMENT OF ANY SOFT CHECKS Y

P-MODE:AUTHORITY LEVEL-TIME CLOCK AUTH. LEVEL # 99 DESCRIPTOR XXXXXXXXXXXX ALLOW CLOCK-IN / OUT ENTRY ONLY Y MGR REQUIRED ON CLOCK-IN Y MGR REQUIRED ON JOB CODE CHANGE Y ENFORCE CLOCK-IN BEFORE SALES ENTRY Y ENFORCE OUT FOR BREAK OR OUT ENTRY Y ENFORCE TIME CLOCK VIA EMPLOYEE CARD Y ENFORCE CSHR SGN-ON VIA EMPLOYEE CARD Y ALLOW CLOCK-OUT IF OPEN CHECKS/ORDERS Y

132 ◆ NEC RSenCounter 4000 Reference Manual 2350REF01

Page 141: NEC4000 Programming

P-MODEP-MODE MENU STRUCTURE

REPORT [P10-5-1-9]

CREDIT CARD [P10-5-1-10]

P-MODE:AUTHORITY LEVEL-REPORT AUTH. LEVEL # 99 DESCRIPTOR XXXXXXXXXXXX ALLOW X1 REPORTS Y ALLOW X2 REPORTS Y ALLOW Z1 REPORTS Y ALLOW Z2 REPORTS Y ALLOW PRE-POLL Y ALLOW PRINT & RESET SYSTEM LOG Y

P-MODE:AUTHORITY LEVEL-CREDIT CARD AUTH. LEVEL # 99 DESCRIPTOR XXXXXXXXXXXX

ALLOW POST TRANSACTIONS IN X-MODE Y ALLOW FORCE AUTH Y ALLOW Z-MODE CC BATCH COMMANDS Y ALLOW MANUAL CREDIT CARD # ENTRY Y ALLOW TIP EDIT OF OWN SOFT CHECKS Y ALLOW TIP EDIT OF ANY SOFT CHECKS Y

2350REF01 NEC RSenCounter 4000 Reference Manual ◆ 133

Page 142: NEC4000 Programming

P-MODEP-MODE MENU STRUCTURE

Authority Level [P10-5-1]: Programming fields and related flags.

Field Descriptor Default Auth. 1

Default for Auth. 2-30 Explanation

GLOBAL

AUTH. LEVEL # 1

DESCRIPTOR MANAGER

ALLOW ADJUST CLOSED CHECK TENDER Y N

ALLOW MANAGER REQUIRED FUNCTION Y N

ALWAYS OPEN DRAWER 0 0 If 0, then do not allow TENDER KEYs

X-MODE EDIT

# 1

DESCRIPTOR MANAGER

ALLOW CASH/CHECK DECLARATION Y N

ALLOW KEYBOARD, PRICE, & KP LEVEL SET

Y N

ALLOW TIME CLOCK EDIT Y N

ALLOW DRAWER ASSIGN Y N

ALLOW SYSTEM STATUS TABLE EDIT Y N

ALLOW FILE MAINTANANCE Y N

P-MODE EDIT – PLU

# 1

DESCRIPTOR MANAGER

ALLOW PLU/PLU PPTY EDIT Y N

ALLOW ONLY PLU PRICE EDIT N N

ALLOW COND./TLU/MLU/L.PLU TBL EDIT Y N

P-MODE EDIT – EMPLOYEE

# 1

DESCRIPTOR MANAGER

ALLOW AUTHORITY LEVEL EDIT Y N

ALLOW EMPLOYEE FILE EDIT Y N

ALLOW JOB CODE EDIT Y N

ALLOW PAY RATE EDIT Y N

ALLOW H. RESOURCE OPTION FLAGS EDIT

Y N

134 ◆ NEC RSenCounter 4000 Reference Manual 2350REF01

Page 143: NEC4000 Programming

P-MODEP-MODE MENU STRUCTURE

P-MODE EDIT – MISCELLANEOUS

# 1

DESCRIPTOR MANAGER

ALLOW EDIT SYSTEM CONFIGURATION EDIT

Y N

ALLOW SYSTEM OPTION EDIT Y N

ALLOW FUNCTION KEY EDIT Y N

ALLOW CPN. AND AUTO-COMBO OPTION EDIT

Y N

ALLOW ALL OTHER P-MODE EDITS Y N

TRANSACTION

# 1

DESCRIPTOR MANAGER

DEFAULT KEYBOARD LEVEL 1 1

ALLOW DESTINATION CHANGE Y N

ALLOW PRICE TABLE OVER-RIDE Y N

ALLOW PLU PRICE OVER-RIDE Y N

ALLOW NO SALE, R/A & P/O Y N

ENABLE OPERATOR / CLERK INTERRUPT N N

ALLOW CANC. OF DT Q’D ORDER IN X MODE

N N ORDER # + [CANCEL] in X-mode at DT CSHR or DT OT CSHR

TABLE SERVICE OPERATION

# 1

DESCRIPTOR MANAGER

ENFORCE CHECK CREATION N N

ENFORCE SEAT# ENTRY FOR EACH ITEM N N

ALLOW CANCEL AFTER RECALL Y N

ALLOW VOIDS OF SERVICED ITEMS Y N

ALLOW EDIT ANY SOFT CHECKS Y N

ALLOW COMBINE OWN SOFT CHECKS Y Y

ALLOW COMBINE ANY SOFT CHECKS Y N

ALLOW TRANSFER OF CHECKS Y N

ALLOW TABLE# CHANGE IN R-MODE Y N

Authority Level [P10-5-1]: Programming fields and related flags.

Field Descriptor Default Auth. 1

Default for Auth. 2-30 Explanation

2350REF01 NEC RSenCounter 4000 Reference Manual ◆ 135

Page 144: NEC4000 Programming

P-MODEP-MODE MENU STRUCTURE

ALLOW PAYMENT OF OWN SOFT CHECKS Y Y

ALLOW PAYMENT OF ANY SOFT CHECKS Y N

TIME CLOCK

# 1

DESCRIPTOR MANAGER

ALLOW CLOCK-IN / OUT ENTRY ONLY N N

MGR. REQUIRED CLOCK - IN N Y

MGR. REQUIRED ON JOB CODE CHANGE N Y

ENFORCE CLOCK-IN BEFORE SALES ENTRY

N Y

ENFORCE OUT FOR BREAK OR OUT ENTRY

N Y

ENFORCE TIME CLOCK VIA EMPLOYEE CARD

N N

ENFORCE CSHR SIGN-ON VIA EMPLOYEE CARD

N N

ALLOW CLOCK-OUT IF OPEN CHECKS/ORDERS

N N

REPORT

# 1

DESCRIPTOR MANAGER

ALLOW X1 REPORTS Y N

ALLOW X2 REPORTS Y N

ALLOW Z1 REPORTS Y N

ALLOW Z2 REPORTS Y N

ALLOW PRE-POLL Y N

ALLOW PRINT & RESET SYSTEM LOG Y N

CREDIT CARD

ALLOW POST TRANSACTIONS IN X-MODE Y N

ALLOW FORCE AUTH Y N

ALLOW Z-MODE CC BATCH COMMANDS Y N

ALLOW MANUAL CREDIT CARD # ENTRY Y Y

ALLOW TIP EDIT OF OWN SOFT CHECKS Y y

ALLOW TIP EDIT OF ANY SOFT CHECKS y N

Authority Level [P10-5-1]: Programming fields and related flags.

Field Descriptor Default Auth. 1

Default for Auth. 2-30 Explanation

136 ◆ NEC RSenCounter 4000 Reference Manual 2350REF01

Page 145: NEC4000 Programming

P-MODEP-MODE MENU STRUCTURE

PRINT EMPLOYEE LIST [P10-6]

PERIPHERALS [P11]

CREATE/EDIT PRINTER LIST (1-30) [P11-1]

● Two pages of this list to accommodate maximum of 30 printers.

☞ [1][Enter] or [Down arrow] [Enter]

CREATE/EDIT PRINTER LIST [P11-1-1]

RECEIPT/REPORT/LOG PRINTER ASSIGNMENT [P11-2]

P-MODE :PRINT EMPLOYEE LIST1 ACTIVE EMPLOYEES LIST2 INACTIVE EMPLOYEES LIST3 ALL EMPLOYEE LIST4 CASHIER/SERVER LIST

P-MODE :PERIPHERALS1 CREATE/EDIT LIST2 RECEIPT/REPORT/LOG PRINTER ASSIGNMENT3 CREATE/EDIT KITCHEN PRINTER TABLE4 KP TABLE ASSIGNMENT TO KP LEVEL5 KVS PROGRAMMING6 SCALE7 CREDIT CARD INTERFACE8 SCANNER

P-MODE:CREATE/EDIT PRINTER LIST # DESCRIPTOR MODEL STA.-PORT 99 ABCDEFGHIJKL ABCDEFGHIJKL 88-7

P-MODE:CREATE/EDIT PRINTER LIST # DESCRIPTOR MODEL STA.-PORT01 ABCDEFGHIJKL EPSON TM-T80 01 - 302 BAR RECEIPT EPSON TM-T80 02 - 503 KITCHEN HOT EPSON TM300 03 - 104 FLOOR RCPT EPSON TM-T88 04 - 105

P-MODE:CREATE/EDIT PRINTER LIST PRINTER # (1-30) 99 DESCRIPTOR XXXXXXXXXXXX STATION (0-24) 99 PORT # (0-5) 9

PRINTER MODEL (0- ) 9 (0=EPSON TM-T88 ) (1=EPSON TM-200 ) (2=CITIZEN 3541 ) (3=FUTURE USE )

P-MODE:RECEIPT/LOG/SLIP PRINTER ASSIGNMENT# DESCRIPTOR99 ABCDEFGHIJKL 99=1-24 STA. LIST

2350REF01 NEC RSenCounter 4000 Reference Manual ◆ 137

Page 146: NEC4000 Programming

P-MODEP-MODE MENU STRUCTURE

☞ [1][Enter] or [Enter]

RECEIPT/REPORT/LOG PRINTER ASSIGNMENT [P11-2-1]

● *5 0 = NO CONNECTION

● *6 “9” Reserved for the future use.

● *8 Refer to CTS (CLOSED TRANSACTION SUMMARY) [P4-5-8] on page 42.

● First selection in the printer list is “NONE”

● *2 Divide Journal into SYSTEM LOG and TRANS. LOG. If Memory is not allocated, then directly output to the printer.

P-MODE :RECEIPT/LOG/SLIP PRINTER ASSIGNMENT---#--DESCRIPTOR--- 1 STATION 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15

Receipt/Report/Log Printer Assignment [P11-2]: Programming fields and related flags.

Field Descriptor Default Explanation

# Enter Station Number

DESCRIPTOR Station Descriptor

P-MODE:RECEIPT/REPORT/LOG PRINTER ASSIGNMENT STATION # (1-24) 99 DESCRIPTOR XXXXXXXXXXXX

RECEIPT: DEFAULT (0-30) 99 *5BACK UP (0-30) 99 *5

REPORT: *6,8DEFAULT (0-30) 99 *5BACKUP (0-30) 99 *5

SYS. LOG: (0=PRT,1=EJ) 9DEFAULT (0-30) 99 *5BACK UP (0-30) 99 *5

TRANS.LOG:(0=PRT,1=EJ) 9DEFAULT (0-30) 99 *5BACK UP (0-30) 99 *5

138 ◆ NEC RSenCounter 4000 Reference Manual 2350REF01

Page 147: NEC4000 Programming

P-MODEP-MODE MENU STRUCTURE

● Same for station 1-24

● Transaction and System Log RoutingIf memory is allocated for Transaction and/or System log, each station will start buffering infor-mation in the allocated area.

Once its memory is filled up, then the station will prompt to clear or output to the designated peripheral programmed here.

If memory is not allocated, then the station will output its information directly to the peripheral programmed here.

CREATE/EDIT KITCHEN PRINTER TABLE [P11-3](1-Mem. Alloc. 30 max)

● *1 One page lists up to 15 KP Tables, # of pages depends on memory allocation.

Receipt/Report/Log Printer Assignment [P11-2-1]: Programming fields and related flags.

Field Descriptor Default Explanation

STATION # Own station #

DESCRIPTOR Station Descriptor

RECEIPT: DEFAULT (STATION 1 PORT 1)

BACK UP 0

REPORT: DEFAULT (STATION 1 PORT 1)

BACK UP 0

SYS LOG: 0

DEFAULT 0

BACK UP 0

TRANS LOG: 0

DEFAULT 0

BACK UP 0

P-MODE:CREATE/EDIT KITCHEN PRINTER TABLE# DESCRIPTOR99 ABCDEFGHIJKL 99=1-(MEM. ALLOC. )KP

TBL LIST

P-MODE :CREATE/EDIT KITCHEN PRINTER TABLE# DESCRIPTOR01 CNTR LUNCH02 DT LUNCH03 PHONE ORDER04 CNTR BKFST05 SLOW PERIO

2350REF01 NEC RSenCounter 4000 Reference Manual ◆ 139

Page 148: NEC4000 Programming

P-MODEP-MODE MENU STRUCTURE

☞ [1][Enter] or [Enter]

KP TABLE [P11-3-1]

● *1,2 Also refer to the KITCHEN REQUISITION [P4-5-3] on page 37.

● *2 Condiment(s) following the Main item are grouped together.

● *2 Selections are listed at Col. 43 to 52

● 1 KP Table (4 page screen) can hold up to 8 kitchen printers.

● 30 KPGs are available to choose from.

Create/Edit Kitchen Printer Table [P11-3]: Programming fields and related flags.

Field Descriptor Default Explanation

# Enter KP TBL #

DESCRIPTOR KP TBL descriptor

P-MODE:CREATE/EDIT KITCHEN PRINTER TABLE (1/4) KP TBL # 99 1-(Memory Allocation Max.30) DESCRIPTOR XXXXXXXXXXXX # 1 GRILLABCDEFG SELECT (0=NONE,1=FROM,2=EXCEPT) 9 RANGE *2 KPGs # 99 99 99 99 99 99 99 99 99 99 KPGs=1-30 TO KP 99 KP=1-30 BACK UP 99 BKUP=0-30 PRINT/CUT BY KPG Y *1 # 2 GRILLABCDEFG SELECT (0=NONE,1=FROM,2=EXCEPT) 9 KPGs # 99 99 99 99 99 99 99 99 99 99 TO KP 99 BACK UP 99 PRINT/CUT BY KPG Y CUT BY ITEM Y

Example: KPG KPG KPGMain Item 01 01 01

Condiment 00 01 02Grouped Grouped Cut after the main item

P-MODE:CREATE/EDIT KITCHEN PRINTER TABLE (4/4) KP TBL # 99 DESCRIPTOR XXXXXXXXXXXX # 7 GRILLABCDEFG SELECT (0=NONE,1=FROM,2=EXCEPT) 9 RANGE *2 KPGs # 99 99 99 99 99 99 99 99 99 99 KPGs=1-30 TO KP 99 KP=1-30 BACK UP 99 BKUP=0-30 PRINT/CUT BY KPG Y *1 # 8 GRILLABCDEFG SELECT (0=NONE,1=FROM,2=EXCEPT) 9 KPGs # 99 99 99 99 99 99 99 99 99 99 TO KP 99 BACK UP 99 PRINT/CUT BY KPG Y

140 ◆ NEC RSenCounter 4000 Reference Manual 2350REF01

Page 149: NEC4000 Programming

P-MODEP-MODE MENU STRUCTURE

● 10 Kitchen Printer Groups can be assigned to one KP if “FROM” is selected.

● If “PRINT/CUT BY KPG=Y”, then above KPGs will be printed from left KPG to right KPG.

● First Selection in the printer list is “NONE”

● Same for the station 1-24

KP TABLE ASSIGNMENT TO KP LEVEL [P11-4]Page 1 for STA#1-14, Page 2 for STA#15-24.

● Points to own station by default

☞ [Enter]

Create/Edit Kitchen Table Printer [P11-3-1]: Programming fields and related flags. Page 1/4-4/4

Field Descriptor Default Explanation

KP TBL # Max # depends on Memory Allocation

DESCRIPTION Enter KP Table descriptor.

# 1 (same for #2 to 8)

(Virtual KP descriptor)

SELECT 1

KPGs # 0 Register up to 10 KP groups.

TO KP 0 Define Main KP for this KPGs.

BACK UP 0 Define backup KP for this KPGs

PRINT/CUT BY KPG N If printer with no cut feature, then cut will be ignored, just print by KPG

P-MODE:KP TABLE ASSIGNMENT TO KP LEVEL# DESCRIPTOR KP LVL 1 KP LVL 299 ABCDEFGHIJKL 88 88 99=1-24 STA. LIST,

88=1-(MEM. ALLOC. 30)

P-MODE :KP TABLE ASSIGNMENT TO KP LEVEL# DESCRIPTOR KP LVL 1 KP LVL 201 COUNTER 1 1 202 COUNTER 2 5 603 T OT 12 11

KP Table Assignment to KP Level [P11-4]: Programming fields and related flags.

Field Descriptor Default Explanation

# Enter station number

DESCRIPTOR Station Descriptor

KP LVL 1 Display assigned KP TBL #

KP LVL 2 Display assigned KP TBL #

2350REF01 NEC RSenCounter 4000 Reference Manual ◆ 141

Page 150: NEC4000 Programming

P-MODEP-MODE MENU STRUCTURE

KP TABLE ASSIGNMENT TO KP LEVEL [P11-4-1]

● *1 Table Descriptor is display only

KVS PROGRAMMING [P11-5]

P-MODE:KP TABLE ASSIGNMENT TO KP LEVEL STATION # (1-24) 99 DESCRIPTOR XXXXXXXXXXXX

KP LEVEL KP TBL # DESCRIPTOR LEVEL 1 99 XXXXXXXXXXXX (0-Allocation # of KP Tbl) LEVEL 2 99 XXXXXXXXXXXX *1 LEVEL 3 99 XXXXXXXXXXXX LEVEL 4 99 XXXXXXXXXXXX LEVEL 5 99 XXXXXXXXXXXX

KP Table Assignment to KP Level [P11-4-1]: Programming fields and related flags.

Field Descriptor Default Explanation

STATION #

DESCRIPTOR Station Descriptor

KP LEVEL

KP TBL # LEVEL 1-5 = KP TABLE 1

DESCRIPTOR KP TBL DESCRIPTOR

P-MODE:KVS PROGRAMMINGENABLE KVS Y Y/N METHOD(0=TENDER, 1=SBTL 9 0-3 2=ITEM DELAY, 3=NO ITEM DELAY) KVS BACK UP PRINTER # (0-30) 99 0-30# OF KVS RETIRES 6

KVS Programming [P11-5-1]: Programming fields and related flags.

Field Descriptor Default Explanation

ENABLE KVS N Fixed LAN address =Station # 25

METHOD 2 ITEM DELAY is one item delay.

NO ITEM DELAY method will fol-low the same way as DT Order Con-firmation Board (P11-9-8).

KVS BACK UP PRINTER # 0

# OF KVS RETIRES 6

142 ◆ NEC RSenCounter 4000 Reference Manual 2350REF01

Page 151: NEC4000 Programming

P-MODEP-MODE MENU STRUCTURE

SCALE [P11-6]

☞ [Enter]

SCALE [P11-6-1]

☞ 2 [Enter]

P-MODE :SCALE1 SCALE INTERFACE2 SCALE TARE WEIGHT

P-MODE:SCALE INTERFACE PORT # (0-5) 0 ENABLE SCALE N SCALE TYPE (0=NCI, 1=TERAOKA) 0 PRINT FORMAT (0=US, 1=AU) 0 SCALE AUTO Y ALLOW MANUAL WEIGHT ENTRY N

BASE WEIGHT (0=POUNDS, 1=KILOGRAMS) 0 ROUND SCALE FRACTIONS 1 (0=DOWN, 1=NORMAL, 2=UP) DECIMAL POINT FOR WEIGHT 3 POSITION SCALE DECIMAL IN X/Z REPORTS 0 (0=NONE, 1=FIRST, 2=SECOND, 3=THIRD)

Scale [P11-6-1]: Programming fields and related flags.

Field Descriptor Default Explanation

PORT # (0-5) 0 0-5

ENABLE SCALE N

SCALE TYPE 0 0=NCI, 1=TERAOKA

PRINT FORMAT 0 0=US, 1=AU

SCALE AUTO Y

ALLOW MANUAL WEIGHT ENTRY

N

BASE WEIGHT 0 0=POUNDS, 1=KILOGRAMS

ROUND SCALE FRACTIONS N 0=DOWN, 1=NORMAL, 2=UP

DECIMAL POINT FOR WEIGHT 3

POSITION SCALE DECIMAL IN X/Z REPORTS

0 0=NONE, 1=FIRST, 2=SECOND, 3=THIRD

2350REF01 NEC RSenCounter 4000 Reference Manual ◆ 143

Page 152: NEC4000 Programming

P-MODEP-MODE MENU STRUCTURE

TARE WEIGHT TABLE [P11-6-2]

☞ [Enter]

CREDIT CARD INTERFACE [P11-7]

P-MODE:TARE WEIGHT TABLE----#--DESCRIPTOR-- --TARE WEIGHT— 1 0.000 2 0.000 3 0.000 4 0.000 5 0.000 6 0.000 7 0.000 8 0.000 9 0.000 10 0.000 11 0.000 12 0.000 13 0.000 14 0.000 15 0.000

P-MODE:TARE WEIGHT TABLE # 1 DESCRIPTOR TARE WEIGHT 0.000

Tare Weight Table [P11-6-2]: Programming fields and related flags.

Field Descriptor Default Explanation

DESCRIPTOR 12 characters

TARE WEIGHT 0.000

P-MODE :CREDIT CARD INTERFACE1 OPTION2 CREDIT CARD MODEM LIST3 STATION ASSIGNMENT TO CC MODEM4 CREDIT CARD TYPE CONFIGURATION5 TERMINAL MODE

144 ◆ NEC RSenCounter 4000 Reference Manual 2350REF01

Page 153: NEC4000 Programming

P-MODEP-MODE MENU STRUCTURE

CREDIT CARD INTERFACE (P11-7-1]

CREDIT CARD MODEM LIST [P11-7-2]

☞ [1][Enter] or [Down arrow] [Enter]

Credit Card Modem List [P11-7-2-1]

● Note: Upon [EXIT], if there is more than 1 CC Modem is assigned to one station, then ‘INVALID ENTRY [013]”

P-MODE:OPTION ALLOW TIPS ENTRY (RESTAURANT) Y SEND REFERENCE N PRINT CUSTOMER COPY Y PRINT ITEMS ON RECEIPT Y PRINT # OF CC SETTLEMENT COPIES 9 PRINT CC DETAIL AT BATCH SETTLEMNT Y PRINT X ON ACCOUNT NUMBER Y PRINT EXP. DATE Y

Credit Card Interface [P11-7-1]: Programming fields and related flags.

Field Descriptor Default Explanation

ALLOW TIPS ENTRY (RESTAURANT) N

SEND REFERENCE N

PRINT CUSTOMER COPY Y

PRINT ITEMS ON RECEIPT Y

PRINT # OF CC SETTLEMENT COPIES 0

PRINT CC DETAIL AT BATCH SET-TLEMENT

N

PRINT X ON ACCOUNT NUMBER N

PRINT EXP. DATE N

P-MODE:CREDIT CARD MODEM LIST# DESCRIPTOR STA.-PORT9 ABCDEFGHIJKL 99-5

P-MODE:CREDIT CARD MODEM LIST CREDIT CARD MODEM # (1-9) 9 DESCRIPTOR XXXXXXXXXXXX STATION (0-24) 99 PORT # (0-5) 9

2350REF01 NEC RSenCounter 4000 Reference Manual ◆ 145

Page 154: NEC4000 Programming

P-MODEP-MODE MENU STRUCTURE

CREDIT CARD MODEM ASSIGNMENT [P11-7-3]

Credit Card Modem Assignment [P11-7-3-X]

CREDIT CARD TYPE CONFIGURATION [P11-7-4]

Page 1/2 for 01-16 and Page 2/2 for 17-32Example:

P-MODE:STATION ASSIGNMENT TO CC MODEM# DESCRIPTOR MODEM99 ABCDEFGHIJKL TAKE OUT9012 (10-3)

Credit Card Modem Assignment [P11-7-3]: Programming fields and related flags.

Field Descriptor Default Explanation

STATION # Enter Station Number

DESCRIPTOR Station Descriptor

MODEM DATATRAN 1 Modem Descriptor

PP PORT 0 PIN PAD PORT

P-MODE:STATION ASSIGNMENT TO CC MODEM STATION # (1-24) 99 DESCRIPTOR STATION 1 Display only from CC

modem list See “CREDIT CARD MODEM LIST [P11-7-2]” on page 145.

MODEM: ENABLE CREDIT CARD INTERFACE Y Enable ‘SWIPE A CARD’ USE MODEM # (1-9) 9

RESPONSE TIME OUT (SECS) 999 (Max 180 seconds) LOG PRINTER # (0-30) 99

Credit Card Modem Assignment [P11-7-3-x]: Programming fields and related flags.

Field Descriptor Default Explanation

MODEM:

ENABLE CREDIT CARD INTERFACE N

USE CC MODEM # (1-9) 1

RESPONSE TIME OUT (SECS) 120

LOG PRINTER # (0-30) 0

P-MODE:CREDIT CARD TYPE CONFIGURATION# DESCRIPTOR START-END LENGTH TYPE#

01 AMEX 34 - 15 2 02 AMEX 37 - 15 2 03 VISA 4 - 13 3 04 VISA 4 - 16 3 05 MASTER 5 - 16 5 06 DEBIT 16 9 07 HOUSE 9999- 9 0

146 ◆ NEC RSenCounter 4000 Reference Manual 2350REF01

Page 155: NEC4000 Programming

P-MODEP-MODE MENU STRUCTURE

Credit Card Type Configuration [P11-7-4-X]

● Type Configuration Table (Refer to Data Tran Programmer’s Reference Manual page 56, B)

TERMINAL MODE [P11-7-5]

[AT&UP96]

● The number of characters are limited to 120.

☞ [ENTER]

P-MODE:CREDIT CARD TYPE CONFIGURATION CARD CONFIGURATION # (1-30) 99 ASSIGNED CHARGE KEY CODE# (60-69) 999 DESCRIPTOR :AMEX Display only based on

Charge Fnc. Code

CARD DEFINITION: ACCOUNT NUMBER START 9999 END 9999 ACCOUNT NUMBER LENGTH 99 TYPE# ASSIGNED BY INTERFACE 99

Credit Card Type Configuration [P11-7-4-x]: Programming fields and related flags.

Field Descriptor Default Explanation

CARD CONFIGURATION # Card registration number from 01 to 30.

ASSIGNED CHARGE KEY CODE# (60-69) Enter #60-69, which you would like to report to.

DESCRIPTOR : Display only from Charge function Key.

CARD DEFINITION:

ACCOUNT NUMBER START Register maximum 4 digits of Account num-ber from a left.Example: 30 35 means Account number starting with 30, 31, 32, 33, 34, and 35 will fall in this category if the length of its account number matches that specified in LENGTH. Blank in the START field will be interpreted as a wild card. Blank in the END field will be interpreted as showing no range, in short, only START field will be the applicable field.

END

ACCOUNT NUMBER LENGTH Length of a Account number for this Card Type.

TYPE# ASSIGNED BY INTERFACE The number registered here will link to MEDIA TYPE field in a Function Key (KEY-CODE#60 to #69)

P-MODE:TERMINAL MODE

CC MODEM:24-3 EAT IN DTRAN AT&UP96

[ENTER] TO START COMMUNICATION

2350REF01 NEC RSenCounter 4000 Reference Manual ◆ 147

Page 156: NEC4000 Programming

P-MODEP-MODE MENU STRUCTURE

● Issued command would return a response (MAX 240 CHRS) like this from DATA TRAN. This response would be printed to receipt and journal

● Used for DataTran communication only. Do not use Terminal Mode unless instructed to do so by a CRS or DataCap representative.

SCANNER [P11-8]

☞ [Enter]

SCANNER INTERFACE [P11-8-1]

☞ 2 [Enter]

P-MODE:TERMINAL MODE CC MODEM:24-3 EAT IN DTRAN AT&UP96

[ENTER] TO START COMMUNICATION NDC CHK --- --- Ver:3.56 OK OFF OFF OFF

P-MODE:SCALE1 SCANNER INTERFACE2 EAN13 INF. EMBEDDED BAR CODE

P-MODE:SCANNER INTERFACE PORT # (0-5) 0 DATA BIT LENGTH (7 OR 8) 7 STOP BIT LENGTH (1 OR 2) 2 PARITY (0=NO, 1=ODD, 2=EVEN) 2

Scanner Interface [P11-8-1]: Programming fields and related flags.

Field Descriptor Default Explanation

PORT # (0-5) 0 0-5

DATA BIT LENGTH 7 7 OR 8

STOP BIT LENGTH () 2 1 OR 2

PARITY 2 0=NO, 1=ODD, 2=EVEN

148 ◆ NEC RSenCounter 4000 Reference Manual 2350REF01

Page 157: NEC4000 Programming

P-MODEP-MODE MENU STRUCTURE

EAN13 INF. EMBEDDED BAR CODE [P11-8-2]

OTHER PERIPHERAL CONFIGURATIONS [P11-15]

POLLING MODEM CONNECTION [P11-15-1]

P-MODE:EAN13 INF. EMBEDDED BAR CODE

ITEM (=PLU) LENGTH 0 LEN. OF EMBEDED INF. (10ITEM LEN.) 0 EMBEDDED INF. (0=PRICE,1=WEIGHT) 0 DECIMAL POINT (0-3) 0 PRICE CHECK DIGIT IN BAR CODE N

EAN13 Inf. Embedded Bar Code [P11-8-2]: Programming fields and related flags.

Field Descriptor Default Explanation

ITEM (=PLU) LENGTH 0

LEN. OF EMBEDED INF. 0 10 ITEM LEN.

EMBEDDED INF. 0 0=PRICE, 1=WEIGHT

DECIMAL POINT 0 0-3

PRICE CHECK DIGIT IN BAR CODE

N

P-MODE :OTHER PERIPHERAL CONFIGURATIONS1 POLLING MODEM CONNECTION2 USER CARD DEFINITION3 EMPLOYEE CARD CONFIGURATION

6 DOWNLOAD LOGO TO TM-T887 POLE DISPLAY8 DRIVE THRU ORDER CONFIRMATION BOARD

P-MODE:POLLING MODEM CONNECTIONSTORE ID # 999999 Display onlySTORE NAME XXXXXXXXXXXX Display only

STATION # (0-24) 99DESCRIPTOR XXXXXXXXXXXX Display onlyPORT # (0-5) 9

BAUD RATE (0=2.4K, 1=4.8K 9 If PORT #=3, then accept 0-4, otherwise only accept 0-3. 2=9.6K, 3=19.2K, 4=38.4K)

2350REF01 NEC RSenCounter 4000 Reference Manual ◆ 149

Page 158: NEC4000 Programming

P-MODEP-MODE MENU STRUCTURE

USER CARD DEFINITION [P11-15-2]

EMPLOYEE CARD CONFIGURATION [P11-15-3]

Polling Modem Connection [P11-15-1]: Programming fields and related flags.

Field Descriptor Default Explanation

STORE ID # : 0 Just display information

STORE NAME : Just display information

STATION # Select station from the list

DESCRIPTOR DISPLAY ONLY

PORT # 0 Enter the port number to which a polling modem is connected

BAUD RATE 2 Port 3 can go up to 38400 bps

P-MODE:USER CARD DEFINITIONFIND THE DEFINITION ON TRACK 1 OR 2 9AT COLUMN # 99

DEFINITION: (CLEAR TO EDIT)EMPLOYEE CARD ID # 9

User Card Definition [P11-15-2]: Programming fields and related flags.

Field Descriptor Default Explanation

FIND THE DEFINITION ON TRACK 1 OR 2

0

AT COLUMN # 0

DEFINITION: (CLEAR TO EDIT)

EMPLOYEE CARD ID # 1

P-MODE:EMPLOYEE CARD CONFIGURATION USE EMPLOYEE CARD Y

CARD FORMAT: READ TRACK 1 OR 2 9 EMPL. KEY CODE: STARTING COLUMN 99 # OF DIGITS 99 USE CARD ID Y STARTING COLUMN 99 # OF DIGITS 99 CARD ID # 9999999999 USE EXP. DATE (MM/YY) Y STARTING COLUMN 99

150 ◆ NEC RSenCounter 4000 Reference Manual 2350REF01

Page 159: NEC4000 Programming

P-MODEP-MODE MENU STRUCTURE

● Note: Configuring Employee Card, Universal Card 1To determine a card upon a swipe, the following fixed code is assigned at the column 1.

● # assignment : “EMPLOYEE CARD” =1

DOWNLOAD LOGO TO TM-T88 [P11-15-6]

Employee Card Configuration [P11-15-3]: Programming fields and related flags.

Field Descriptor Default Explanation

USE EMPLOYEE CARD N If N, then when a employee card is swiped, it will not read the card.

CARD FORMAT:

READ TRACK 1 OR 2 2

EMPL. KEY CODE :

STARTING COLUMN

# OF DIGITS

USE CARD ID N

STARTING COLUMN

# OF DIGITS

CARD ID # 0

USE EXP. DATE (MM/YY)

STARTING COLUMN

P-MODE:DOWNLOAD LOGO TO TM-T88 PORT # (1-5) 0

PRINTING FORMAT (0=NORMAL, 0 1=D.WIDTH, 2=D.HEIGHT, 3=DW&DH)

ARE YOU SURE? N

Download Logo to TM-T88 [P11-15-6]: Programming fields and related flags.

Field Descriptor Default Explanation

PORT# 0 Enter the port number to which the printer is connected

PRINTING FORMAT 0 0=NORMAL, 1=D.WIDTH, 2=D.HEIGHT, 3=DW&DH

ARE YOU SURE? N To download, change to Y and press ENTER, then EXIT.

2350REF01 NEC RSenCounter 4000 Reference Manual ◆ 151

Page 160: NEC4000 Programming

P-MODEP-MODE MENU STRUCTURE

POLE DISPLAY [P11-15-7]

DRIVE THRU ORDER CONFIRMATION BOARD (OCB) [P11-15-8]

● Reflect [ERROR CORR.] and Condiments in voiding.

P-MODE:POLE DISPLAY PORT # (0-5) 9

Pole Display [P11-15-7]: Programming fields and related flags.

Field Descriptor Default Explanation

PORT# 0 Enter port# to which a poll display is con-nected.

P-MODE:DRIVE THRU ORDER CONFIRMATION BOARD STA# 0 PORT # (0-5) 0

BAUD RATE (0=2.4K, 1=4.8K, 2 If PORT #= ‘3’, then allow 0-4, otherwise only allow 0-3 1=9.6K, 2=19.2K, 3=38.4K)

Drive Thru Order Confirmation Board [P11-15-8]: Programming fields and related flags.

Field Descriptor Default Explanation

STA# 0 Station OC board is connected to.

PORT# 0 Enter the port number to which a DT Order Confirmation display is connected.

4BAUD RATE (0=2.4K, 1=2.4K, 2=9.6K, 3=19.2K, 4=38.4K)

2

152 ◆ NEC RSenCounter 4000 Reference Manual 2350REF01

Page 161: NEC4000 Programming

P-MODEP-MODE MENU STRUCTURE

Time over if there is no response from the OCB in 500ms after a transmission from the station.

Refresh Command will be issued to OCB on VOID or CONDIMENT insertion by cursor.If all items are voided, then [REFRESH] [NO DATA] is sent to OCB.

Example of Data Layout for $100.002710h=10000

Data Type 1

Data Type 2

Communication Format

Item Data Type Length (Byte) Note

Data Type 1 Byte 1 Refer to Data Type 1Data Type 2 Byte 1 Refer to Data Type 2Descriptor Chr 21 (20 characters max)Reserved Chr 1 Future useQty/Weight Long 4 Refer to Data LayoutAmount Long 4 DittoTax Total Long 4 DittoTotal Long 4 DittoColor Byte 1 0-15Indent Byte 1 0=Yes, 1=No

Total 42 bytes 1

Data (High) 00Data (High) 00Data (Low) 27Data (Low) 10

Number Definition0 Normal1 Void2 Refund3 Error Correct4 Subtotal5 Tender6 Cancel7 Refresh

Number Definition0 No Data1 Main Item2 Condiment3 Item Discount4 Surcharge5 Order Discount6 Store Coupon7 Vendor Coupon8 Auto-Combo9 Reserved (Future use)10 Message

2350REF01 NEC RSenCounter 4000 Reference Manual ◆ 153

Page 162: NEC4000 Programming

P-MODEP-MODE MENU STRUCTURE

Example 1 :Main PLU

Example 1 :Subtotal

PRINT A LIST BY STATION [P11-16]

● ALL STATIONS = ACTIVE STATIONS

● BY STATION GROUP= ALL STATIONS in the designated group regardless of ACTIVE or INACTIVE.

● BY STATION NUMBER = ALL STATIONS in the designated range regardless of ACTIVE or INACTIVE.

● Use fixed Peripheral Descriptor for the following equipment. Pole Display / Scale / DT Order CFB / Scanner / POLL Modem

● Use the programmable Peripheral Descriptor for the following equipment. Printer # 1-30Credit Card Modem 1-9

Number DefinitionData Type 1 0Data Type 2 1Descriptor HamburgerReserved 0Qty 2Amount 700Tax Total 35Total 735Color 15Indent 0

Number DefinitionData Type 1 4Data Type 2 0Descriptor SubtotalReserved 0Qty 0Amount 0Tax Total 35Total 735Color 15Indent 0

P-MODE :PRINT A LIST BY STATION1 ALL STATIONS2 BY STATION GROUP3 BY STATION NUMBER

154 ◆ NEC RSenCounter 4000 Reference Manual 2350REF01

Page 163: NEC4000 Programming

P-MODEP-MODE MENU STRUCTURE

PRINT A LIST BY PERIPHERAL [P11-17]

● Notes on the above menu and descriptors referenced to are the same as PRINT A LIST BY STA-TION [P11-16] on page 154.

● If no peripheral is assigned to a port (means xx-x = 0-00), then do not print the line.

● There are 3 formats in this list;1) PRINTER LIST & CC MODEM LIST2) SCANER, POLE DISPLAY, & SCALE3) DT ORDER CFB, POLL MODEM, & CC MODEM ASN

#

S PERIPHERALS/PRINT A LIST BY STATIONS RANGE :01-24 ALL/STATION GROUP:COUNTER/RANGE:01-06

S SUCCCESSFUL STA: (01 02 03 04 05 06 07 08 09 10 11 12 13 14 15)

S COMM. ERROR STA: (16 17 18 19 20 21 22 23 24)

--------------------------------------------------------P STA # 01 FLOORabcdefg STA descriptor following station numberP PORT 1 PRINTER 1

PORT 2 POLE DISPLAY PORT 3 POLL MODEM PORT 4 SCALE PORT 5 DT ORDER CFB--------------------------------------------------------STA # 02 BAR COUNTER PORT 1 PRINTER 2 PORT 1 PRINTER 3 Note 1: If print as shown if the Same port is used by

mistake PORT 2 PRINTER 4 PORT 3 SCALE PORT 4 POLE DISPLAY PORT 5 PRINTER 7 |--------------------------------------------------------STA # 24 BAR COUNTER PORT 1 PRINTER 5 PORT 2 PRINTER 6 PORT 3 SCALE-------------------------------------------------------- Note 2: If there is nothing attached then do not print.

P-MODE :PRINT A LIST BY PERIPHERAL1 ALL STATIONS2 BY STATION GROUP3 BY STATION NUMBER

2350REF01 NEC RSenCounter 4000 Reference Manual ◆ 155

Page 164: NEC4000 Programming

P-MODEP-MODE MENU STRUCTURE

#

S PERIPHERALS/PRINT A LIST BY PERIPHERALS RANGE :01-24 ALL/STATION GROUP:COUNTER/

RANGE:01-06S SUCCCESSFUL STA:

(01 02 03 04 05 06 07 08 09 10 11 12 13 14 15)

S COMM. ERROR STA: (16 17 18 19 20 21 22 23 24)

--------------------------------------------------------------PRINTER LIST (STA - PORT#) 1 FLOOR RCPT (FLOOR STATIO –1) 23-1 |30 BAR COUNTER (BAR MACHINE –3) 2-3--------------------------------------------------------------CC. MODEM (STA - PORT#) 1 COUNTER TRML (CNTR STATION -1) 24-1 | 9 BAR COUNTER (BAR MACHINE –4) 2-4

--------------------------------------------------------------SCANNER (STA - PORT#) (PHONE ORDER -1) 1-1 (BAR MACHINE –2) 2-2 (TAKE OUT STA -2) 3-2 | (CNTR STATION -2) 24-2--------------------------------------------------------------POLE DISPLAY (STA - PORT#) (PHONE ORDER -2) 1-2 (BAR MACHINE –1) 2-1 (TAKE OUT STA -3) 3-3 | (CNTR STATION -3) 24-3--------------------------------------------------------------SCALE (STA - PORT#) SAME AS ABOVE--------------------------------------------------------------POLL MODEM (STA - PORT#) 1 PHONE ORDER (PHONE ORDER –3) 1-524 CNTR STATION (TAKE OUT STA -1) 3-1--------------------------------------------------------------DT ORDER CFB (STA - PORT#) 1 PHONE ORDER ->(PHONE ORDER –3) 1-3 2 BAR MACHINE ->(PHONE ORDER –3) 1-3 | 24 CNTR STATION ->(PHONE ORDER –4) 1-4-------------------------------------------------------------- CC MODEM ASN (STA - PORT#) 1 PHONE ORDER ->(CNTR STATION -1) 24-1 2 BAR MACHINE ->(BAR MACHINE -4) 2-4 | 24 CNTR STATION ->(CNTR STATION -1) 24-1

156 ◆ NEC RSenCounter 4000 Reference Manual 2350REF01

Page 165: NEC4000 Programming

P-MODEP-MODE MENU STRUCTURE

RS-232 WIRING DIAGRAMS

Item SpecificationCash Drawer 2 ports

Connector type: Modular RJ-11Recommended Cash drawer: 24VDC, 1AOn/Off pulse : 100 msec

Pin Number Pin Name Input/Output Notes1 Signal GND I2 DRV I Drive Signal3 N.C. -4 Signal GND I5 STATUS I Open/Close Status6 +24V O Drive Voltage

Item SpecificationRS-232C 3 ports (standard)

2 Ports (option) . . with installed expansion boardConnector Type: Modular RJ-45

Pin Number Pin Name Input/Output Notes1 DTR O 2 DSR I3 TXD O4 RXD I5 RTS O6 CTS I7 Signal GND I8 CD I

2350REF01 NEC RSenCounter 4000 Reference Manual ◆ 157

Page 166: NEC4000 Programming

P-MODEP-MODE MENU STRUCTURE

TRAINING [P12]

TRANSACTION OPTION [P12-1]

REPORT OPTION [P12-2]

PRINTING OPTION [P12-3]

P-MODE :TRAINING1 TRANSACTION OPTION2 REPORT OPTION3 PRINTING OPTION

P-MODE:TRAINING/TRANSACTION OPTION OPEN DRAWER IN TRAINING MODE Y ALLOW REAR DISPLAY IN TRAINING Y INCREMENT TRANSACTION NUMBER Y MGR REQUIRED ON TRAINING Y

P-MODE:TRAINING/REPORT OPTION DESIGNATED TRAINING CASHIER FILE # 999 PRINT TRAINING GT ON X REPORT Y PRINT TRAINING GT ON Z REPORT Y PRINT TRAINING ON TRANS. LOG Y

P-MODE:TRAINING/PRINTING OPTION PRINT KP IN TRAINING MODE Y PRINT SYSTEM DESCRIPTOR "TRAINING" Y

Transaction/Report/Printing Option [P12-1/2/3]: Programming fields and related flags.

Field Descriptor Default Explanation

TRANSACTION OPTION

OPEN DRAWER IN TRAINING MODE N

ALLOW REAR DISPLAY IN TRAINING N

INCREMENT TRANSACTION NUMBER N

MGR REQUIRED ON TRAINING Y

REPORT OPTION

DESIGNATED TRAINING CASHIER FILE # 0

PRINT TRAINING GT ON X REPORT Y

PRINT TRAINING GT ON Z REPORT Y

PRINT TRAINING ON TRANS. LOG Y

PRINTING OPTION

PRINT KP IN TRAINING MODE N

PRINT SYSTEM DESCRIPTOR “TRAINING” Y

158 ◆ NEC RSenCounter 4000 Reference Manual 2350REF01

Page 167: NEC4000 Programming

P-MODEP-MODE MENU STRUCTURE

UTILITY [P13]

DOWNLOAD PROGRAM [P13-1] OR AFTER [P12-1-2]

DOWNLOAD APPLICATION PROGRAMS-All [P13-1-1]

DOWNLOAD APPLICATION PROGRAMS BY STATION GROUP [P13-1-2] / [P12-3]

DOWNLOAD APPLICATION PROGRAMS BY STATION NUMBER [P13-1-1-3] / [P12-3]

P-MODE :UTILITY1 DOWNLOAD APPLICATION PROGRAMS2 Z1 & PRE-POLL Z1 STRINGS3 Z2 & PRE-POLL Z2 STRINGS4 PROGRAM PRINT

P-MODE DOWNLOAD APPLICATION PROGRAMS 1/2 1 SYSTEM CONFIGURATION2 REPORT GROUPS AND TIME PERIODS3 TAXES4 SYSTEM OPTION5 PLU6 INVENTORY7 MESSAGES8 KEYBOARD SYSTEM9 COUPON AND AUTO-COMBO10 HUMAN RESOURCES11 PERIPHERALS12 TRAINING13 PRE-POLL STRING AND SCHEDULER14 X-MODE DATA15 GRAPHIC PRINTER LOGO16 ALL

P-MODE :DOWNLOAD APPLICATION PROGRAMS-ALL 2/2 1 ALL STATIONS2 BY STATION GROUP3 BY STATION NUMBER

P-MODE:ALL-BY STATION GROUP DOWNLOAD TO STATION GROUP (1-24) 99

Download by Station Group [P13-1-1-2] Programming fields and related flags.

Field Descriptor Default Explanation

DOWNLOAD TO STATION GROUP 0 Select the station group to download program(s) from the list.

P-MODE:ALL-BY STATION NUMBER DOWNLOAD TO STATION NUMBER : FROM (1-24) 99 TO (1-24) 99

2350REF01 NEC RSenCounter 4000 Reference Manual ◆ 159

Page 168: NEC4000 Programming

P-MODEP-MODE MENU STRUCTURE

Z1 AND PRE-POLL Z1 STRINGS [P13-2]

● Maximum of 10 strings.

Z1 & PRE-POLL Z1 STRINGS # 1 [P13-2-1]

Download Application Programs by Station Number [P13-1-1-3]: Programming fields and related flags.

Field Descriptor Default Explanation

DOWNLOAD TO STATION NUMBER :

FROM 0

TO 0

P-MODE:Z1 AND PRE-POLL Z1 STRINGS# DESCRIPTOR REPORT RANGE99 ABCDEFGHIJKL PP.Z1 01-24

P-MODE:Z1 AND PRE-POLL Z1 STRINGS# DESCRIPTOR REPORT RANGE01 DAILY SALES PP. Z1 01-2402 D. GROUPS PP. Z1 01-2403 DAILY T.K. Z1 01-2404 D. FINANCIAL Z1 01-2405 D. LOG Z1 01-24

P-MODE:Z1 & PRE-POLL Z1 STRINGS (1/2) SCHEDULE # (1-10) 99 DESCRIPTOR XXXXXXXXXXXX REPORT TYPE (0=Z1, 1=PRE-POLL Z1) 9 RANGE(0=SYS.WIDE,1=STA.GRP., 2=STA.) 9 STATION (0-24) START 99 END 99 Skip on RANGE=0 or 1 STA. GRP.(0-24) 99 Skip on RANGE=0 or 2 RUN AT (99:99=DISABLED) 99:99 PRINT REPORT Y 1 FINANCIAL Y 2 CASH DEPOSIT Y 3 DAY SHIFT Y 4 CASHIER/SERVER Y 5 ITEM/PLU Y 6 PLU PRICE TABLE BY LEVEL Y 7 SUB GROUP Y 8 MAJOR GROUP Y 9 PRODUCT MIX GROUP Y

160 ◆ NEC RSenCounter 4000 Reference Manual 2350REF01

Page 169: NEC4000 Programming

P-MODEP-MODE MENU STRUCTURE

P-MODE:Z1 & PRE-POLL Z1 STRINGS (2/2) SCHEDULE # 99 Display only DESCRIPTOR XXXXXXXXXXXX 10 DT SERVICE TIME (MASTER ONLY) Y 11 COUPONS Y 12 AUTO-COMBO Y 13 TIME PERIOD ALL SALES Y 14 TIME PERIOD EAT-IN Y 15 TIME PERIOD TAKE-OUT Y 16 TIME PERIOD TRACK 1 Y 17 TIME PERIOD TRACK 2 Y 18 TIME PERIOD DT Y

20 TRANSACTION LOG Y Skip on REPORT TYPE=1 21 SYSTEM LOG Y 22 23 TIME & ATTENDANCE Y 24 SALES & LABOR % Y

Pre-Poll Z1 Strings [P13-2]: Programming fields and related flags.

Field Descriptor Default Explanation

# Select Schedule #

DESCRIPTOR ‘Z1 REPT STRING’ for the

1st Rec.

REPORT

RANGE Shown as 99-99

2350REF01 NEC RSenCounter 4000 Reference Manual ◆ 161

Page 170: NEC4000 Programming

P-MODEP-MODE MENU STRUCTURE

● Note 1:Pre-Poll of Z1 or Z2 will not be allowed more than number of times set in the S-Mode Memory allocation. Pre-polled data is polled and cleared by either PC or Manually at NEC RSenCounter 4000.

Pre-polled Data is polled in FIFO fashion.

If RUN AT time is 00:00, then this string will not run.

A time activated string will not be queued, if the station is busy (such as during edit, taking report, or etc.) when it is activated.

Z2 AND PRE-POLL Z2 STRINGS [P13-3]

● Maximum of 7 strings.

Pre-Poll Z1 Strings [P13-2-1]: Programming fields and related flags.

Field Descriptor Default Explanation

SCHEDULE #

DESCRIPTOR ‘Z1 REPT STRING 1’ for the

1st Rec.

REPORT TYPE 0 This will decide which menu to display. Note 1

REPORT RANGE 0

STA. GRP. 0

STATION 0

RUN AT 99:99 99:99 disable auto report taking.

PRINT REPORT Y If Y, then refer to RECEIPT/REPORT/LOG PRINTER ASSIGNMENT [P11-2] on page 137.

Refer to the above menu for a kind of reports available.

N

1P-MODE:Z2 AND PRE-POLL Z2 STRINGS2 # DESCRIPTOR REPORT RANGE 3 9 ABCDEFGHIJKL PP.Z2 01-24 9=1-5

P-MODE :Z2 AND PRE-POLL Z2 STRINGS # DESCRIPTOR REPORT RANGE01 WEEKLY SALES PP. Z2 01-2402 WEEKLY GROUP PP. Z2 01-2403 PERIOD T.K. 01-0104 W. FINANCIAL Z2 01-2405 W. DT Z2 01-24

162 ◆ NEC RSenCounter 4000 Reference Manual 2350REF01

Page 171: NEC4000 Programming

P-MODEP-MODE MENU STRUCTURE

Z2 & PRE-POLL Z2 STRINGS # 1 [P13-3-1]

Z2 and Pre-Poll Z2 Strings [P13-3]: Programming fields and related flags.

Field Descriptor Default Explanation

# Select Schedule #

DESCRIPTOR ‘Z2 REPT STRING ’ for the

1st Rec.

REPORT

RANGE Shown as 99-99

P-MODE:Z2 & PRE-POLL Z2 STRINGS (1/2) SCHEDULE # (1-5) 99 DESCRIPTOR XXXXXXXXXXXX REPORT TYPE (0=Z2, 1=PRE-POLL Z2) 9 RANGE(0=SYS.WIDE,1=STA.GRP., 2=STA.) 9 STATION (0-24) START 99 END 99 Skip on RANGE=0 or 1 STA. GRP.(0-24) 99 Skip on RANGE=0 or 2 PRINT REPORT Y 1 FINANCIAL Y 2 BUSINESS FLASH RPT. (ONLY MASTER) Y 3 CASHIER/SERVER Y 4 ITEM/PLU Y 5 PLU PRICE TABLE BY LEVEL Y 6 SUB GROUP Y 7 MAJOR GROUP Y 8 PRODUCT MIX GROUP Y 9 DT SERVICE TIME Y

P-MODE:Z2 & PRE-POLL Z2 STRINGS (2/2) SCHEDULE # 99 Display only DESCRIPTOR XXXXXXXXXXXX 10 COUPONS Y 11 AUTO-COMBO Y 13 TIME PERIOD ALL SALES Y 14 TIME PERIOD EAT-IN Y 15 TIME PERIOD TAKE-OUT Y 16 TIME PERIOD TRACK 1 Y 17 TIME PERIOD TRACK 2 Y 18 TIME PERIOD DT Y 19 20 SALES & LABOR % Y

2350REF01 NEC RSenCounter 4000 Reference Manual ◆ 163

Page 172: NEC4000 Programming

P-MODEP-MODE MENU STRUCTURE

Z2 and Pre-Poll Z2 Strings [P13-3-1]: Programming fields and related flags.

Field Descriptor Default Explanation

SCHEDULE #

DESCRIPTOR

REPORT TYPE 0 This will decide which menu to display

REPORT RANGE 0

STA. GRP. 0

STATION 0

PRINT REPORT Y If Y, then refer to RECEIPT/REPORT/LOG PRINTER ASSIGNMENT [P11-2] on page 137.

Refer to the above menu for a kind of reports available.

164 ◆ NEC RSenCounter 4000 Reference Manual 2350REF01

Page 173: NEC4000 Programming

P-MODEP-MODE MENU STRUCTURE

PROGRAM PRINT [P13-4]

SYSTEM CONFIGURATION [P13-4-1]

REPORT GROUPS AND TIME PERIOD [P13-4-2]

P-MODE :PROGRAM PRINT1 SYSTEM CONFIGURATION2 REPORT GRUOPS AND TIME PERIOD3 TAXES4 SYSTEM OPTION5 PLU6 INVENTORY7 MESSAGES8 KEYBOARD SYSTEM9 COUPON AND AUTO-COMBO10 HUMAN RESOURCES11 PERIPHERALS12 TRAINING13 PRE-POLL AND Z STRINGS

15 MEMORY ALLOCATION16 ALL PROGRAMS

------------------------------------------------------------------------------*** SYSTEM CONFIGURATION ***

1. SYSTEM WIDE FEATURE

[P1-1][1/2] (2, 2)-(41, 18) [P1-1][2/2] (2, 2)-(41, 2)------------------------------------------------------------------------------ <--- Print Fixed Line (Not Cut)2. STATION GROUP

# DESCRIPTOR 1 XXXXXXXXXXXX 2 XXXXXXXXXXXX | | 24 XXXXXXXXXXXX------------------------------------------------------------------------------3. STATION REGISTRATION

[P1-3-1] (2, 2)-(41, 15) Print for 24 Stations------------------------------------------------------------------------------ Space between Records4. MASTER & BACK UP ASSIGNMENT

[P1-4] (2, 2)-(41, 7)------------------------------------------------------------------------------

P-MODE:PROGRAM PRINT-REPORT GROUPS AND TIME PERIOD1 SUB GROUP2 MAJOR GROUP3 PRODUCT MIX GROUP4 TIME PERIOD

2350REF01 NEC RSenCounter 4000 Reference Manual ◆ 165

Page 174: NEC4000 Programming

P-MODEP-MODE MENU STRUCTURE

SUB GROUP [P13-4-2-1] 1-(999)

MAJOR GROUP [P13-4-2-2] 1-(99)

PRODUCT MIX GROUP [P13-4-2-3] 1-(99)

---------------------------------------------------------------------------*** SUB GROUP ***TOTAL SUB GROUP = 999

# DESCRIPTOR MAJ GRP SALES RPT1 XXXXXXXXXXXX 99 92 XXXXXXXXXXXX 99 9: : : :

999 XXXXXXXXXXXX 99 9 1-(Memory Allocation)---------------------------------------------------------------------------

---------------------------------------------------------------------------*** MAJOR GROUP ***TOTAL MAJOR GROUP = 99

# DESCRIPTOR ON RCPT. ON T.P.RPT1 XXXXXXXXXXXX Y Y2 XXXXXXXXXXXX Y Y: : : :

99 XXXXXXXXXXXX Y Y 1-(Memory Allocation)---------------------------------------------------------------------------

---------------------------------------------------------------------------*** PRODUCT MIX GROUP ***TOTAL PRODUCT MIX GROUP = 99

# DESCRIPTOR PCS/UNIT UNIT DESC1 XXXXXXXXXXXX 99 XXXX2 XXXXXXXXXXXX 99 XXXX: : : :

99 XXXXXXXXXXXX 99 XXXX 1-(Memory Allocation)---------------------------------------------------------------------------

166 ◆ NEC RSenCounter 4000 Reference Manual 2350REF01

Page 175: NEC4000 Programming

P-MODEP-MODE MENU STRUCTURE

TAXES [P13-4-3]

(1-6)

---------------------------------------------------------------------------*** TAXES ***

1.TAX CONFIGURATION

[P3-1-1] (2, 2)-(41, 9) Do not print s space lineLine Feed between TAX Records

--------------------------------------------------------------------------- Print this separator2.TAX TABLE PROGRAMMING

TAX TABLE 1 [P3-2-1][1/2] (2, 2)-(41, 12) [P3-2-1][2/2] (2, 6)-(41, 12)

TAX TABLE 2 [P3-2-1][1/2] (2, 2)-(41, 12) [P3-2-1][2/2] (2, 6)-(41, 12)

---------------------------------------------------------------------------4.TAX OPTION [P3-3] (2, 2)-(41, 3)

2350REF01 NEC RSenCounter 4000 Reference Manual ◆ 167

Page 176: NEC4000 Programming

P-MODEP-MODE MENU STRUCTURE

SYSTEM OPTION [P13-4-4]---------------------------------------------------------------------------*** SYSTEM OPTION ***

1.GLOBAL OPTION

[P4-1] (2, 2)-(41, 15)---------------------------------------------------------------------------2.TRANSACTION OPTION

[P4-2] (2, 2)-(41, 14) Do not print a space line.---------------------------------------------------------------------------3. TABLE SERVICE OPTION

[P4-3] (2, 2)-(41, 5)---------------------------------------------------------------------------4.DRAWER & TENDER OPTION

[P4-4] (2, 2)-(41, 17)---------------------------------------------------------------------------5.PRINT FORMAT AND OPTION

1.RECEIPT OPTION [P4-5-1] (2, 2)-(41, 6)

2.RECEIPT FORMAT [P4-5-2] (2, 2)-(41, 15)

3.KITCHEN REQUISTION [P4-5-3] (2, 2)-(41, 15) Do not print a space line.

4.REPORT [P4-5-4] (2, 2)-(41, 15)

5.CLOSED TRANSACTION LOG [P4-5-5] (2, 2)-(41, 2)

6.SYSTEM LOG [P4-5-6] (2, 2)-(41, 14)---------------------------------------------------------------------------6.CLOSING OPTION

[P4-6] (2, 2)-(41, 9)---------------------------------------------------------------------------7.DISPLAY OPTION

[P4-7] (2, 2)-(41, 2)----------------------------------------8.SCREEN CONFIGURATION

1.ORDER/CHECK INFORMATION LINE [P4-8-1] (2, 2)-(41, 8)

2.ITEM LINE [P4-8-2] (2, 2)-(41, 9)

3.ACTION LINE [P4-8-3] (2, 2)-(41, 3)

4.SERVICE INFORMATION LINE [P4-8-4] (2, 2)-(41, 3)

5.STATUS LINE [P4-8-5] (2, 2)-(41, 3)

6.TENDER INFORMATION LINE [P4-8-6] (2, 2)-(41, 6)

168 ◆ NEC RSenCounter 4000 Reference Manual 2350REF01

Page 177: NEC4000 Programming

P-MODEP-MODE MENU STRUCTURE

PLU [P13-4-5]

(1-200)

Title: PLU PROPERTY

Title: PLU

P-MODE :PROGRAM PRINT-PLU1 PLU2 PLU PROPERTY3 PLU SHIFT TYPE4 PLU PRICE TABLE5 PLU BY PRICE TABLE6 PLU PRICE SCHEDULE7 PLU PRICE LIST8 CONDIMENT TABLE9 CONDIMENT CHAIN10 LINKED PLU TABLE11 DISCOUNT CATEGORY12 PLUS RECEIPT DESCRIPTOR

*** PLU SHIFT ***TOTAL PLU SHIFT = 200

# DESCRIPTOR VALUE TYPE COLOR1 XXXXXXXXXXXX 999999 9 992 XXXXXXXXXXXX 999999 9 99: : : : :

200 XXXXXXXXXXXX 999999 9 99 1-(Memory Allocation)

*** PLU PROPERTY ***TOTAL PLU PROPERTY = 2500

[P5-2][1/3] (2, 2)-(41, 17) Do not print a space line.[P5-2][2/3] (2, 5)-(41, 15) Do not print a space line.[P5-2][3/3] (2, 5)-(41, 12) Do not print a space line.

Line feed between records.

*** PLU ***TOTAL PLU = 2500/2500 # of PLU Registered/PLU

Mem. Alloc.0001 PLU # 99999999999999[P5-3-1-1/2500][1/2] (2, 3)-(41, 18) Do not print a space line.[P5-3-1-1/2500][2/2] (2, 5)-(41, 5) Line Feed between records.

1 2 3 4

*** OPTIONAL PLU RECEIPT DESCRIPTOR ***TOTAL PLU RECEIPT DESCRIPTOR = 999

# DESCRIPTOR1 XXXXXXXXXXXXXXXXXXXXXXXX2 XXXXXXXXXXXXXXXXXXXXXXXX: :999 XXXXXXXXXXXXXXXXXXXXXXXX

2350REF01 NEC RSenCounter 4000 Reference Manual ◆ 169

Page 178: NEC4000 Programming

P-MODEP-MODE MENU STRUCTURE

Title: EDIT KP/KVG DESCRIPTOR 1-(999)

*** KP/KVS DESCRIPTOR ***TOTAL KP/KVG DESCRIPTOR = 999

# DESCRIPTOR 1 XXXXXXXXXXXX 2 XXXXXXXXXXXX : : 999 XXXXXXXXXXXX

*** PLU PRICE TABLE ***TOTAL PLU PRICE TABLE = 999

[P5-5] (2, 2)-(41, 12) Do not print a space line.

*** PLU PRICE LEVEL SCHEDULER ***

[P5-6] (2, 2)-(41, 13) Do not print a space line.

*** CONDIMENT TABLE ***TOTAL CONDIMENT TABLE = 999

[P5-7][1/3] (2, 2)-(41, 17) Line Feed between records. [P5-7][2/3] (2, 9)-(41, 17)[P5-7][3/3] (2, 9)-(41, 17)

*** CONDIMENT CHAIN ***TOTAL CONDIMENT CHAIN = 999

[P5-8-1/999] (2, 2)-(41, 17) Do not print a space line.Line Feed between records.

*** LINKED PLU TABLE ***TOTAL LINKED PLU TABLE = 999/999

[P5-9-1/999] (2, 2) - (41, 17) Do not print a space line.Line Feed between records.

*** DISCOUNT CATEGORY ***

# DESCRIPTOR 1 XXXXXXXXXXXX 2 XXXXXXXXXXXX : : 99 XXXXXXXXXXXX

170 ◆ NEC RSenCounter 4000 Reference Manual 2350REF01

Page 179: NEC4000 Programming

P-MODEP-MODE MENU STRUCTURE

INVENTORY [P13-4-6]

MESSAGES [P13-4-7]

*** SPECIAL ITEM STOCK ***TOTAL SPECIAL ITEM STOCK = 999

[P6-1-2-1] (2, 2)-(41, 8)

*** MESSAGES ***

1.SCREEN MESSAGE

1.SCREEN MESSAGE (SHORT)

# USER DEFINED MSG. TEXT COLOR1 XXXXXXXX 992 XXXXXXXX 99: : :

200 XXXXXXXX 99

2.SCREEN MESSAGE (LONG)

# USER DEFINED MSG. TEXT COLOR1 XXXXXXXXXXXXXXXX 992 XXXXXXXXXXXXXXXX 99: : :

100 XXXXXXXXXXXXXXXX 99

3.SCREEN ERROR MESSAGE

# USER ERROR MSG. CLR1 XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX 99

200 XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX 99

4.DEFAULT SYSTEM COLOR[P7-1-4] (2, 2)-(41, 12)---------------------------------------------------------------------------------------------2.RECEIPT/CHECK MESSAGE

1.RECEIPT/GUEST CHECK HEADER AND FOOTER

[P7-2-1] (2, 3)-(41, 17) Do not print a space line.

2.RECEIPT/GUEST CHECK SYSTEM MESSAGE# USER DEFINED MSG.1 XXXXXXXXXXXX2 XXXXXXXXXXXX: :

150 XXXXXXXXXXXX

3.CREDIT CARD AGREEMENT MESSAGE (CHARGE)

[P7-2-3] (2, 3)-(41, 8)

4.CREDIT CARD AGREEMENT MESSAGE (CREDIT)

[P7-2-4] (2, 3)-(41, 14)

5.GUEST CHECK TAIL MESSAGE

[P7-2-5] (2, 3)- (41, 12)---------------------------------------------------------------------------------------------

2350REF01 NEC RSenCounter 4000 Reference Manual ◆ 171

Page 180: NEC4000 Programming

P-MODEP-MODE MENU STRUCTURE

3. KITCHEN PRINTER MESSAGE

1.KP HEADER AND FOOTER

[P7-3-1] (2, 3)-(41, 13) Do not print a space line.

2.KP GROUP DESCRIPTOR

# DESCRIPTOR1 XXXXXXXXXXXX2 XXXXXXXXXXXX: :

30 XXXXXXXXXXXX--------------------------------------------------------------------------------------------- 4.REPORT MESSAGE

# USER DEFINED MSG.1 XXXXXXXXXXXX2 XXXXXXXXXXXX : :

350 XXXXXXXXXXXX--------------------------------------------------------------------------------------------- 5.MONTH AND TAX MESSAGE

# USER DEFINED MSG1 XXXXXX2 XXXXXX: :

30 XXXXXX---------------------------------------------------------------------------------------------

7.POLE DISPLAY MESSAGE

[P7-6] (2, 2)-(41, 10) Do not print a space line.

172 ◆ NEC RSenCounter 4000 Reference Manual 2350REF01

Page 181: NEC4000 Programming

P-MODEP-MODE MENU STRUCTURE

KEYBOARD SYSTEM [P13-4-8]P-MODE :KEYBOARD SYSTEM1 FUNCTION KEY2 MACRO KEY3 TLU KEY4 MLU KEY5 TIME ACTIVATE KEY6 KEYBOARD LEVEL 17 KEYBOARD LEVEL 28 KEYBOARD LEVEL 39 KEYBOARD LEVEL 410 KEYBOARD LEVEL 5

*** FUNCTION KEY ***

[P8-2-1/249] (2, 2)-(41, 18) Print Function # 0 - 249Do not print Ptn = 0Print by Ptn

*** MACRO KEY ***TOTAL MACRO KEY = 99

[P8-3-2][1/3] (2, 2)-(41, 18)[P8-3-2][2/3] (2, 6)-(41, 18)[P8-3-2][3/3] (2, 6)-(41, 18) Do not print a line with

TYPE=0

*** TIME ACTIVATE KEY ***

[P8-4-1] (2, 2)-(41, 16) Do not print a space line.

*** TLU KEY ***TOTAL TLU KEY = 999

[P8-5-1][1/2] (2, 2)-(41, 16) Do not print a space line.[P8-5-1][2/2] (2, 8)-(41, 16)

*** MLU KEY ***TOTAL MLU KEY = 999

# DESCRIPTOR MGR POPUP BK COLOR1 XXXXXXXXXXXX Y Y 992 XXXXXXXXXXXX Y Y 99: : : : :

999 XXXXXXXXXXXX Y Y 99

*** KEYBOARD LEVEL 1 *** *** KEYBOARD LEVEL 5 ***

# TYPE CODE DESCRIPTOR 1 PLU 99999999999999 XXXXXXXXXXXXXXXX TYPE=FIXED DESCRIPTOR; 2 SHFT 99999999999999 XXXXXXXXXXXXXXXX PLU/SHFT/FUNC/MACR/TLU/

MLU/ : : :132 FUNC 99999999999999 XXXXXXXXXXXXXXXX

2350REF01 NEC RSenCounter 4000 Reference Manual ◆ 173

Page 182: NEC4000 Programming

P-MODEP-MODE MENU STRUCTURE

COUPON AND AUTO-COMBO [P13-4-9]*** COUPON AND AUTO-COMBO ***

1.COUPON AND AUTO-COMBO OPTION

[P9-1] (2, 2)-(41, 3)

-------------------------------------------------2.COUPONTOTAL COUPON = 999

[P9-2-1][1/2] (2, 2)-(41, 18)[P9-2-1][2/2] (2, 6)-(41, 18) Do not print a space line.

Line Feed between records.-------------------------------------------------3.AUTO COMBOTOTAL AUTO COMBO = 99

[P9-3-1][1/2] (2, 2)-(41, 16) Do not print a space line.[P9-3-1][2/2] (2, 5)-(41, 13) Do not print a space line.

Line Feed between records.

174 ◆ NEC RSenCounter 4000 Reference Manual 2350REF01

Page 183: NEC4000 Programming

P-MODEP-MODE MENU STRUCTURE

HUMAN RESOURCES [P13-4-10]*** HUMAN RESOURCES ***

1.TIME & ATTENDANCE

1.GLOBAL OPTIONS

[P10-1-1] (2, 2)-(41, 15)

2.HOLIDAY PAY PROGRAMMING

[P10-1-2] (2, 2)-(41, 8) Print for 15 Holidays

-------------------------------------------------2.EMPLOYEE FILETOTAL EMPLOYEE = 999

[P10-2][1/2] (2, 2)-(41, 18) Do not print a space line.[P10-2][2/2] (2, 5)-(41, 9) Do not print a space line.------------------------------------------------- Line Feed between records.3.JOB CODE TABLE

# DESCRIPTOR IN LABOR CALC.1 XXXXXXXXXXXX Y2 XXXXXXXXXXXX Y: : :

30 XXXXXXXXXXXX Y-------------------------------------------------4.PAY RATE TABLE

# DESCRIPTOR PAY RATE PER HOUR1 XXXXXXXXXXXX XXX9999.99 XXX9999.99 XXX=[Sys-

Wide.CurrMrk]($)2 XXXXXXXXXXXX XXX9999.99: : :

60 XXXXXXXXXXXX XXX9999.99-------------------------------------------------5.AUTHORITY LEVELS[P10-5-1] (2, 2)-(41, 3) Print for 30 Auth. Levels

AUTHORITY LEVEL-GLOBAL[P10-5-1-1] (2, 4)-(41, 6)AUTHORITY LEVEL-X-MODE EDIT[P10-5-1-2] (2, 4)-(41, 8)AUTHORITY LEVEL-P-MODE EDIT-PLU[P10-5-1-3] (2, 4)-(41, 6)AUTHORITY LEVEL-P-MODE EDIT-EMPLOYEE[P10-5-1-4] (2, 4)-(41, 8)AUTHORITY LEVEL-P-MODE EDIT-MISC.[P10-5-1-5] (2, 4)-(41, 8) Do not print a space line.AUTHORITY LEVEL-TRANSACTION[P10-5-1-6] (2, 4)-(41, 9)AUTHORITY LEVEL-TABLE SERVICE OPERATION[P10-5-1-7] (2, 4)-(41, 14)AUTHORITY LEVEL-TIME CLOCK[P10-5-1-8] (2, 4)-(41, 11)AUTHORITY LEVEL-REPORT[P10-5-1-9] (2, 4)-(41, 9)AUTHORITY LEVEL-CREDIT CARD[P10-5-10] (2, 4)-(41, 8)

Line Feed between lines.

2350REF01 NEC RSenCounter 4000 Reference Manual ◆ 175

Page 184: NEC4000 Programming

P-MODEP-MODE MENU STRUCTURE

PERIPHERALS [P13-4-11]*** PERIPHERALS ***

1.CREATE/EDIT PRINTER LIST

# DESCRIPTOR MODEL STA-PORT1 XXXXXXXXXXXX EPSON TM-T88 99-92 XXXXXXXXXXXX CITIZEN 3541 99-9: : : :

30 XXXXXXXXXXXX EPSON TM-T88 99-9

----------------------------------------2.RECEIPT/SLIP/REPORT/LOG PRINTER ASSIGN

[P11-2-1/30] (2, 2)-(41, 18) Print 24 Stations.Line Feed between records.

----------------------------------------3.CREATE/EDIT KITCHEN PRINTER TABLE Print for 30 Tables.

[P11-3-1][1/4] (2, 2)-(41, 18) Do not print a space line.[P11-3-1][2/4] (2, 4)-(41, 18) Do not print a space line.[P11-3-1][3/4] (2, 4)-(41, 18) Do not print a space line.[P11-3-1][4/4] (2, 4)-(41, 18) Do not print a space line.

---------------------------------------- Line Feed between records.4.KP TABLE ASSIGNMENT TO KP LEVEL Print for 24 Stations.

[P11-4-1] (2, 2)-(41, 10) Do not print a space line.---------------------------------------- Line Feed between records.5.DOWNLOAD LOGO TO TMT-88

[P11-5] (2, 2)-(41, 7) Do not print a space line.----------------------------------------6.OTHER PERIPHERAL CONFIGURATIONS

1.POLLING MODEM CONNECTION

[P11-9-1] (2, 2)-(41, 10) Do not print a space line.

2.USER CARD DEFINITION

[P11-9-2] (2, 2)-(41, 8) Do not print a space line.

3.EMPLOYEE CARD CONFIGURATION

[P11-9-3] (2, 2)-(41, 14) Do not print a space line.

7.POLE DISPLAY

[P11-9-7] (2, 2)-(41, 2)

176 ◆ NEC RSenCounter 4000 Reference Manual 2350REF01

Page 185: NEC4000 Programming

P-MODEP-MODE MENU STRUCTURE

TRAINING [P13-4-12]

Z & PRE-POLL STRINGS [P13-4-13]

*** TRAINING ***

1.TRAINING/TRANSACTION OPTION

[P12-1] (2, 2)-(41, 5)---------------------------------------------------------------------------------------2.REPORT OPTION

[P12-2] (2, 2)-(41, 5)---------------------------------------------------------------------------------------3.PRINTING OPTION

[P12-3] (2, 2)-(41, 3)

*** Z & PRE-POLL STRINGS ***

1.Z1 & PRE-POLL Z1 STRINGS Print for 10 Strings.

[P13-2-1][1/2] (2, 2)-(41, 18)[P13-2-1][2/2] (2, 4)-(41, 18)

2.Z2 & PRE-POLL Z2 STRINGS Print for 5 Strings.

[P13-3-1][1/2] (2, 2)-(41, 18) Do not print a space line.[P13-3-1][2/2] (2, 4)-(41, 15)

2350REF01 NEC RSenCounter 4000 Reference Manual ◆ 177

Page 186: NEC4000 Programming

P-MODEP-MODE MENU STRUCTURE

178 ◆ NEC RSenCounter 4000 Reference Manual 2350REF01

Page 187: NEC4000 Programming

Index

Reference Manual Index � 1

AACTION LINE (Line 19), P4-8-3. . . . .45ALL MESSAGES, S6-10-1. . . . .16AUTHORITY LEVEL, P10-5. . . . .130Authority Level, P10-5-1. . . . .131AUTO COMBO PROGRAMMING,

P9-3. . . . .122Auto Combo Programming, P9-3-1. . . . .122

CCLEAR RAM AND INSTALL DEFAULT

PROGRAM, S6-1. . . . .15CLEAR TOTAL AND COUNTERS,

S6-2. . . . .15CLOSING OPTION, P4-6. . . . .43COMMON CONFIGURATION, S3-1. . . . .6CONDIMENT CHAIN, P5-8. . . . .66CONDIMENT CHAIN, P5-8-2. . . . .66CONDIMENT TABLE, P5-7. . . . .64CONDIMENT TABLE, P5-7-1. . . . .64COUPON AND AUTO-COMBO OPTION,

P9-1. . . . .117COUPON AND AUTO-COMBO,

P13-4-9. . . . .174COUPON AND AUTO-COMBO, P9. . . . .117COUPON, P9-2. . . . .118COUPON, P9-2-1. . . . .118CREATE OR EDIT PLU, P5-1-1. . . . .47CREATE OR EDIT PLU, P5-1-1-1. . . . .48CREATE PLU BY RANGE, P5-1-2. . . . .50CREATE/EDIT KITCHEN PRINTER

TABLE, P11-3. . . . .139CREATE/EDIT PRINTER LIST (1-30),

P11-1. . . . .137Create/Edit Printer List, P11-1-1. . . . .137CREDIT CARD AGREEMENT MESSAGE

(CHARGE), P7-3-3. . . . .95CREDIT CARD AGREEMENT MESSAGE

(CHARGE), S6-10-7. . . . .16CREDIT CARD AGREEMENT MESSAGE

(CREDIT), P7-3-4. . . . .95

CREDIT CARD AGREEMENT MESSAGE(CREDIT), S6-10-8. . . . .16

Credit Card Interface (P11-7-1]. . . . .145CREDIT CARD INTERFACE,

P11-7. . . . .144CREDIT CARD MODEM ASSIGNMENT,

P11-7-3. . . . .146Credit Card Modem Assignment,

P11-7-3-X. . . . .146CREDIT CARD MODEM LIST,

P11-7-2. . . . .145Credit Card Modem List, P11-7-2-1. . . . .145Credit Card Type Configuration,

P11-7-4. . . . .146Credit Card Type Configuration,

P11-7-4-X. . . . .147CREDIT CARD, P10-5-1-10. . . . .133CTS (CLOSED TRANSACTION

SUMMARY), P4-5-8. . . . .42

DDEFAULT SYSTEM COLOR, P7-2-4. . . . .89DELETE PLU BY RANGE, P5-1-4. . . . .52DELETE PLU, P5-1-3. . . . .50Delete PLU, P5-1-3-1. . . . .51DISCOUNT CATEGORY, P5-10. . . . .68DISCOUNT CATEGORY, P5-10-1. . . . .68DISPLAY OPTION, P4-7. . . . .44Download Application Programs by Station

Group, P13-1-2 / P12-3. . . . .159Download Application Programs by Station

Number, P13-1-1-3 / P12-3. . . . .159Download Application Programs-All,

P13-1-1. . . . .159DOWNLOAD LOGO TO TM-T88,

P11-15-6. . . . .151

Page 188: NEC4000 Programming

Index

2 � Index Reference Manual

DOWNLOAD PROGRAM, P13-1/P12-1-2. . . . .159

DOWNLOAD PROGRAMS, S5. . . . .13DOWNLOAD SYSTEM CONFIGURATION,

P1-5. . . . .23DOWNLOAD, P5-13. . . . .72DRAWER AND TENDER OPTION,

P4-4. . . . .35Drive Thru Order Confirmation Board (OCB),

P11-15-8. . . . .152

EEAN13 Inf. Embedded Bar Code,

P11-8-2. . . . .149EDIT FUNCTION KEY FROM A LIST,

P8-2. . . . .111EDIT FUNCTION KEY FROM A LIST,

P8-2-1. . . . .111EDIT FUNCTION KEY FROM

KEYBOARD, P8-1. . . . .110Edit Function Key From Keyboard,

P8-1-1. . . . .110EDIT KP/KVG DESCRIPTOR. . . . .170EDIT KP/KVS DESCRIPTOR, P5-1-8. . . . .54EDIT KP/KVS DESCRIPTOR,

P5-1-8-1. . . . .55EDIT MACRO KEY, P8-3. . . . .111EDIT MEMORY ALLOCATION TABLE,

S3. . . . .6EDIT OPTIONAL PLU RECEIPT

DESCRIPTOR, P5-1-7. . . . .54EDIT OPTIONAL PLU RECEIPT

DESCRIPTOR, P5-1-7-1. . . . .54EDIT SYSTEM CONFIGURATION. . . . .19EMPLOYEE CARD CONFIGURATION,

P11-15-3. . . . .150EMPLOYEE FILE, P10-1. . . . .124EMPLOYEE FILE, P10-1-1/999. . . . .125ERROR MESSAGE, P7-2-3. . . . .83ERROR MESSAGE, P7-2-3-1. . . . .83

FFixed Screen Message on Action Line. . . . .74

GGLOBAL OPTION, P4-1. . . . .31GLOBAL OPTIONS, P10-2-1. . . . .126GLOBAL, P10-5-1-1. . . . .131GUEST CHECK TRAIL MESSAGE,

P7-3-5. . . . .96GUEST CHECK TRAIL MESSAGE,

S6-10-9. . . . .16

HHOLIDAY PAY PROGRAMMING,

P10-2-2. . . . .127HOLIDAY PAY PROGRAMMING,

P10-2-2-1. . . . .128HUMAN RESOURCES, P10. . . . .124HUMAN RESOURCES, P13-4-10. . . . .175

IINITIALIZATION, S6. . . . .15INSTALL DEFAULT FUNCTION KEYS,

S6-11. . . . .16INSTALL DEFAULT KEYBOARD,

S6-12. . . . .16INSTALL DEFAULT MESSAGES,

S6-10. . . . .15Installation Procedure. . . . .14INVENTORY, P13-4-6. . . . .171INVENTORY, P6. . . . .73ITEM LINE (line 2-17), P4-8-2. . . . .45

JJOB CODE TABLE, P10-3. . . . .128Job Code Table, P10-3-1. . . . .129

KKEY ASSIGNMENT, S4. . . . .11KEY BOARD LEVEL 1 Selected,

S4-1. . . . .11Key Location 1, P5-1-9-1-1. . . . .56

Page 189: NEC4000 Programming

Index

Reference Manual Index � 3

KEY STROKE HISTORY, P4-5-7. . . . .42KEYBOARD LEVEL PROGRAMMING,

S4-1-1. . . . .12KEYBOARD SYSTEM, P13-4-8. . . . .173KEYBOARD SYSTEM, P8. . . . .110KITCHEN PRINTER MESSAGE,

P7-4. . . . .97Kitchen Printer Message, P7-4-1. . . . .97KITCHEN PRINTER MESSAGE,

S6-10-10. . . . .16KITCHEN REQUISITION, P4-5-3. . . . .37KP GROUP DESCRIPTOR, P7-4-2. . . . .98KP GROUP DESCRIPTOR, P7-4-2-1. . . . .98KP TABLE ASSIGNMENT TO KP LEVEL,

P11-4. . . . .141KP Table Assignment to KP Level,

P11-4-1. . . . .142KP TABLE, P11-3-1. . . . .140KVS PROGRAMMING, P11-5. . . . .142

LLINKED PLU TABLE (LPT), P5-9-2. . . . .67Linked PLU Table, P5-9. . . . .67LOCAL STATION, S3-4. . . . .10

MMACRO KEY EDIT, P8-3-2. . . . .112MAJOR GROUP Record, P2-1-1. . . . .24MAJOR GROUP, P13-4-2-2. . . . .166MAJOR GROUP, P2-1. . . . .24MASTER AND BACK UP ASSIGNMENT,

P1-4. . . . .23MASTER AND BACK UP ASSIGNMENT,

S2-4. . . . .5MENU KEY RELOCATION – Keyboard

Level 1, P5-1-9-1. . . . .56Menu Key Relocation, P5-1-8-1-1. . . . .57MENU KEY RELOCATION, P5-1-9. . . . .55Menu Structure. . . . .19MESSAGES, P13-4-7. . . . .171MESSAGES, P7. . . . .74

MLU KEY PROGRAMMING, P8-6. . . . .115MLU KEY PROGRAMMING,

P8-6-1. . . . .116MONTH AND DAY MESSAGE,

P7-6. . . . .107MONTH AND DAY MESSAGE,

P7-6-1. . . . .107

OORDER/CHECK INFORMATION LINE

(Line 1), P4-8-1. . . . .44OTHER PERIPHERAL

CONFIGURATIONS, P11-15. . . . .149

PP1. . . . .19P10. . . . .124P10-1. . . . .124P10-1-1/999. . . . .125P10-2. . . . .126P10-2-1. . . . .126P10-2-2. . . . .127P10-2-2-1. . . . .128P10-3. . . . .128P10-3-1. . . . .129P10-4. . . . .129P10-4-1/60. . . . .130P10-5. . . . .130P10-5-1. . . . .131P10-5-1-1. . . . .131P10-5-1-10. . . . .133P10-5-1-2. . . . .131P10-5-1-3. . . . .131P10-5-1-4. . . . .131P10-5-1-5. . . . .132P10-5-1-6. . . . .132P10-5-1-7. . . . .132P10-5-1-8. . . . .132P10-5-1-9. . . . .133P10-6. . . . .137

Page 190: NEC4000 Programming

Index

4 � Index Reference Manual

P1-1. . . . .19P11. . . . .137P11-1. . . . .137P11-1-1. . . . .137P11-15. . . . .149P11-15-1. . . . .149P11-15-2. . . . .150P11-15-3. . . . .150P11-15-6. . . . .151P11-15-7. . . . .152P11-15-8. . . . .152P11-16. . . . .154P11-17. . . . .155P11-2. . . . .137P11-2-1. . . . .138P11-3. . . . .139P11-3-1. . . . .140P11-4. . . . .141P11-4-1. . . . .142P11-5. . . . .142P11-6. . . . .143P11-6-1. . . . .143P11-6-2. . . . .144P11-7. . . . .144P11-7-1. . . . .145P11-7-2. . . . .145P11-7-2-1. . . . .145P11-7-3. . . . .146P11-7-3-X. . . . .146P11-7-4. . . . .146P11-7-4-X. . . . .147P11-7-5. . . . .147P11-8. . . . .148P11-8-1. . . . .148P11-8-2. . . . .149P1-2. . . . .21P12. . . . .158P1-2-1. . . . .21P12-1. . . . .158

P12-1-2. . . . .159P12-2. . . . .158P12-3. . . . .158, 159P1-3. . . . .21P13. . . . .159P1-3-1. . . . .22P13-1. . . . .159P13-1-1. . . . .159P13-1-1-3. . . . .159P13-1-2. . . . .159P13-2. . . . .160P13-2-1. . . . .160P13-3. . . . .162P13-3-1. . . . .163P13-4. . . . .165P13-4-1. . . . .165P13-4-10. . . . .175P13-4-11. . . . .176P13-4-12. . . . .177P13-4-13. . . . .177P13-4-2. . . . .165P13-4-2-1. . . . .166P13-4-2-2. . . . .166P13-4-2-3. . . . .166P13-4-3. . . . .167P13-4-4. . . . .168P13-4-5. . . . .169P13-4-6. . . . .171P13-4-7. . . . .171P13-4-8. . . . .173P13-4-9. . . . .174P1-4. . . . .23P1-5. . . . .23P2. . . . .24P2-1. . . . .24P2-1-1. . . . .24P2-2. . . . .25P2-2-1. . . . .25P2-3. . . . .26

Page 191: NEC4000 Programming

Index

Reference Manual Index � 5

P2-3-1. . . . .26P2-4. . . . .27P2-5. . . . .27P3. . . . .28P3-1. . . . .28P3-1-1. . . . .28P3-2. . . . .29P3-2-1. . . . .29P3-3. . . . .30P4. . . . .31P4-1. . . . .31P4-2. . . . .33P4-3. . . . .34P4-4. . . . .35P4-5. . . . .36P4-5-1. . . . .36P4-5-2. . . . .36P4-5-3. . . . .37P4-5-4. . . . .39P4-5-5. . . . .40P4-5-6. . . . .41P4-5-7. . . . .42P4-5-8. . . . .42P4-6. . . . .43P4-7. . . . .44P4-8. . . . .44P4-8-1. . . . .44P4-8-2. . . . .45P4-8-3. . . . .45P4-8-4. . . . .46P4-8-5. . . . .46P4-8-6. . . . .46P5. . . . .47P5-1. . . . .47P5-10. . . . .68P5-10-1. . . . .68P5-1-1. . . . .47P5-11. . . . .69P5-1-1-1. . . . .48

P5-1-2. . . . .50P5-12-1. . . . .69P5-12-2. . . . .69P5-12-3. . . . .70P5-12-4. . . . .70P5-12-5. . . . .71P5-12-6. . . . .71P5-12-7. . . . .72P5-1-3. . . . .50P5-13. . . . .72P5-1-3-1. . . . .51P5-1-4. . . . .52P5-1-5. . . . .52P5-1-6. . . . .53P5-1-6-1. . . . .53P5-1-7. . . . .54P5-1-7-1. . . . .54P5-1-8. . . . .54P5-1-8-1. . . . .55P5-1-8-1-1. . . . .57P5-1-9. . . . .55P5-1-9-1. . . . .56P5-1-9-1-1. . . . .56P-5-2. . . . .58P5-2-1. . . . .58P5-3. . . . .60P5-3-1. . . . .61P5-4. . . . .61P5-4-1. . . . .62P5-4-1-1. . . . .62P5-5. . . . .62P5-5-1. . . . .63P5-6. . . . .63P5-7. . . . .64P5-7-1. . . . .64P5-8. . . . .66P5-8-2. . . . .66P5-9. . . . .67P5-9-2. . . . .67

Page 192: NEC4000 Programming

Index

6 � Index Reference Manual

P6. . . . .73P6-1-2. . . . .73P7. . . . .74P7-2. . . . .74P7-2-1. . . . .74P7-2-2. . . . .80P7-2-3. . . . .83P7-2-3-1. . . . .83P7-2-4. . . . .89P7-3. . . . .89P7-3-1. . . . .90P7-3-2. . . . .90P7-3-2-1. . . . .90P7-3-3. . . . .95P7-3-4. . . . .95P7-3-5. . . . .96P7-4. . . . .97P7-4-1. . . . .97P7-4-2. . . . .98P7-4-2-1. . . . .98P7-5. . . . .99P7-5-1. . . . .99P7-6. . . . .107P7-6-1. . . . .107P7-7. . . . .109P8. . . . .110P8-1. . . . .110P8-1-1. . . . .110P8-2. . . . .111P8-2-1. . . . .111P8-3. . . . .111P8-3-2. . . . .112P8-4. . . . .113P8-4-1. . . . .114P8-5. . . . .114P8-5-1. . . . .115P8-6. . . . .115P8-6-1. . . . .116P9. . . . .117

P9-1. . . . .117P9-2. . . . .118P9-2-1. . . . .118P9-3. . . . .122P9-3-1. . . . .122PAY RATE TABLE, P10-4. . . . .129Pay Rate Table, P10-4-1/60. . . . .130PERIPHERALS, P11. . . . .137PERIPHERALS, P13-4-11. . . . .176PLU. . . . .169PLU ACCESS FROM KEYBOARD,

P5-1-5. . . . .52PLU ACCESS FROM PLU LIST,

P5-1-6. . . . .53PLU ACCESS FROM PLU LIST,

P5-1-6-1. . . . .53PLU BY DISCOUNT CATEGORY,

P5-12-3. . . . .70PLU BY Menu Look Up, P5-12-4. . . . .70PLU BY PLU PROPERTY, P5-12-2. . . . .69PLU BY PRICE TABLE, P5-12-5. . . . .71PLU PRICE EDIT, P5-4. . . . .61PLU Price Edit, P5-4-1-1. . . . .62PLU PRICE LEVEL SCHEDULER,

P5-6. . . . .63PLU PRICE LIST, P5-12-1. . . . .69PLU PRICE TABLE, P5-5. . . . .62PLU PROGRAMMING, P5. . . . .47PLU PROPERTY. . . . .169PLU PROPERTY, P-5-2. . . . .58PLU SHIFT, P5-3. . . . .60PLU Shift, P5-3-1. . . . .61PLU, P13-4-5. . . . .169PLU, P5-1. . . . .47PLU, P5-2-1. . . . .58P-MODE. . . . .19P-MODE EDIT - EMPLOYEE,

P10-5-1-4. . . . .131P-MODE EDIT - MISCELLANEOUS,

P10-5-1-5. . . . .132

Page 193: NEC4000 Programming

Index

Reference Manual Index � 7

P-MODE EDIT, P10-5-1-3. . . . .131P-MODE MENU STRUCTURE. . . . .19POLE DISPLAY MESSAGE, P7-7. . . . .109POLE DISPLAY, P11-15-7. . . . .152POLLING MODEM CONNECTION,

P11-15-1. . . . .149PRICE EDIT, P5-4-1. . . . .62PRICE Scheduler, P5-12-7. . . . .72PRICE Table, P5-12-6. . . . .71PRICE TABLE, P5-5-1. . . . .63PRINT A LIST BY PERIPHERAL,

P11-17. . . . .155PRINT A LIST BY STATION,

P11-16. . . . .154PRINT EMPLOYEE LIST, P10-6. . . . .137PRINT FORMAT AND OPTION,

P4-5. . . . .36PRINT PLU BY TBL, PRICE LIST, PRICE

SCHEDULER, P5-11. . . . .69PRINTING OPTION, P12-3. . . . .158PRODUCT MIX GROUP, P13-4-2-3. . . . .166PRODUCT MIX GROUP, P2-3. . . . .26PRODUCT MIX GROUP, P2-3-1. . . . .26PROGRAM PRINT, P13-4. . . . .165

RRECEIPT FORMAT, P4-5-2. . . . .36RECEIPT OPTION, P4-5-1. . . . .36RECEIPT/CHECK HEADER AND FOOTER,

S6-10-6. . . . .16RECEIPT/CHECK SYSTEM DESCRIPTOR,

S6-10-5. . . . .16RECEIPT/GUEST CHECK HEADER AND

FOOTER, P7-3-1. . . . .90RECEIPT/GUEST CHECK MESSAGE,

P7-3. . . . .89RECEIPT/GUEST CHECK SYSTEM

MESSAGE, P7-3-2. . . . .90Receipt/Guest Check System Message,

P7-3-2-1. . . . .90

RECEIPT/REPORT/LOG PRINTER ASSIGNMENT, P11-2. . . . .137

Receipt/Report/Log Printer Assignment, P11-2-1. . . . .138

REPORT GROUPS AND TIME PERIOD,P13-4-2. . . . .165

REPORT GROUPS AND TIME PERIODS,P2. . . . .24

REPORT MESSAGE, P7-5. . . . .99REPORT MESSAGE, P7-5-1. . . . .99REPORT MESSAGE, S6-10-11. . . . .16REPORT OPTION, P12-2. . . . .158REPORT, P10-5-1-9. . . . .133REPORT, P4-5-4. . . . .39RS-232 Wiring Diagrams. . . . .157

SS1. . . . .1S2. . . . .1S2-1. . . . .1S2-2. . . . .3S2-2-1. . . . .3S2-3. . . . .4S2-3-1. . . . .4S2-4. . . . .5S3. . . . .6S3-1. . . . .6S3-2. . . . .9S3-3. . . . .9S3-4. . . . .10S4. . . . .11S4-1. . . . .11S4-1-1. . . . .12S5. . . . .13S5-1. . . . .13S5-1-2. . . . .14S5-1-3. . . . .14S6. . . . .15S6-1. . . . .15S6-10. . . . .15

Page 194: NEC4000 Programming

Index

8 � Index Reference Manual

S6-10-1. . . . .16S6-10-10. . . . .16S6-10-11. . . . .16S6-10-2. . . . .16S6-10-5. . . . .16S6-10-6. . . . .16S6-10-7. . . . .16S6-10-8. . . . .16S6-10-9. . . . .16S6-11. . . . .16S6-12. . . . .16S6-2. . . . .15S6-3. . . . .15S6-3 - S6-9. . . . .15S6-4. . . . .15S6-5. . . . .15S6-6. . . . .15S6-7. . . . .15S6-8. . . . .15S6-9. . . . .15S7. . . . .17S8. . . . .17SCALE, P11-6. . . . .143Scale, P11-6-1. . . . .143Scanner Interface, P11-8-1. . . . .148SCANNER, P11-8. . . . .148SCREEN CONFIGURATION, P4-8. . . . .44SCREEN MESSAGE (LONG), P7-2-2. . . . .80SCREEN MESSAGE (SHORT),

P7-2-1. . . . .74SCREEN MESSAGE, P7-2. . . . .74SCREEN SYSTEM DESCRIPTOR, S6-10-

2. . . . .16SERVICE INFORMATION LINE, P4-8-

4. . . . .46S-Mode Installation Procedure. . . . .14S-Mode Menu Structure. . . . .1SPECIAL ITEM STOCK, P6-1-2. . . . .73STATION 1, P1-2-1. . . . .21STATION 1, P1-3-1. . . . .22

STATION 1, S2-2-1. . . . .3STATION 1, S2-3-1. . . . .4STATION GROUP, P1-2. . . . .21STATION GROUP, S2-2. . . . .3Station Number Assignment, S1. . . . .1STATION REGISTRATION, P1-3. . . . .21STATION REGISTRATION, S2-3. . . . .4STATUS LINE, P4-8-5. . . . .46SUB GROUP, P13-4-2-1. . . . .166SUB GROUP, P2-2. . . . .25SUB GROUP, P2-2-1. . . . .25SYSTEM CONFIGURATION,

P13-4-1. . . . .165System Configuration, S2. . . . .1SYSTEM LOG, P4-5-6. . . . .41SYSTEM MASTER, S3-2. . . . .9SYSTEM OPTION, P13-4-4. . . . .168SYSTEM OPTION, P4. . . . .31SYSTEM PASSWORD, S7. . . . .17SYSTEM SOFTWARE, S5-1. . . . .13SYSTEM SOFTWARE-BY RANGE,

S5-1-3. . . . .14SYSTEM SOFTWARE-BY STATION

GROUP, S5-1-2. . . . .14System Test Software. . . . .14SYSTEM TEST, S8. . . . .17SYSTEM WIDE FEATURES, P1-1. . . . .19SYSTEM WIDE FEATURES, S2-1. . . . .1

TTABLE SERVICE OPERATION,

P10-5-1-7. . . . .132TABLE SERVICE OPTION, P4-3. . . . .34Tare Weight Table, P11-6-2. . . . .144TAX 1, P3-1-1. . . . .28TAX CONFIGURATION, P3-1. . . . .28TAX OPTION, P3-3. . . . .30TAX TABLE PROGRAMMING,

P3-2. . . . .29

Page 195: NEC4000 Programming

Index

Reference Manual Index � 9

TAX TABLE PROGRAMMING, P3-2-1. . . . .29

TAXES, P13-4-3. . . . .167TAXES, P3. . . . .28TENDER INFORMATION (Line 17),

P4-8-6. . . . .46Terminal Mode, P11-7-5. . . . .147Test Software. . . . .14TIME & ATTENDANCE, P10-2. . . . .126TIME ACTIVATE KEY, P8-4. . . . .113Time Activate Key, P8-4-1. . . . .114TIME CLOCK, P10-5-1-8. . . . .132TIME PERIOD by MANUAL

CONFIGURATION, P2-5. . . . .27TIME PERIODS AUTO CONFIGURATION,

P2-4. . . . .27TLU KEY PROGRAMMING, P8-5. . . . .114TLU KEY PROGRAMMING,

P8-5-1. . . . .115TRACKING MASTER, S3-3. . . . .9TRAINING, P12. . . . .158TRAINING, P13-4-12. . . . .177TRANSACTION LOG, P4-5-5. . . . .40TRANSACTION OPTION, P12-1. . . . .158TRANSACTION OPTION, P4-2. . . . .33TRANSACTION, P10-5-1-6. . . . .132

UUSER CARD DEFINITION,

P11-15-2. . . . .150UTILITY, P13. . . . .159

XX-MODE EDIT, P10-5-1-2. . . . .131

ZZ & PRE-POLL STRINGS, P13-4-13. . . . .177Z1 & PRE-POLL Z1 STRINGS # 1,

P13-2-1. . . . .160Z1 AND PRE-POLL Z1 STRINGS,

P13-2. . . . .160

Z2 & PRE-POLL Z2 STRINGS # 1, P13-3-1. . . . .163

Z2 AND PRE-POLL Z2 STRINGS, P13-3. . . . .162

Page 196: NEC4000 Programming

Index

10 � Index Reference Manual

Page 197: NEC4000 Programming
Page 198: NEC4000 Programming