Top Banner
NebuTech ® nebulizer from Salter To help you and your patients Striving to be #1 IN PATIENT SATISFACTION breathe easy
10

NebuTech Striving to be nebulizer from Salter SATISFACTION...2. Data on file. Salter Labs; Arvin, CA. 3. Timmons I. Comparison of the efficacy of two nebulizers in treating acute exacerbation

Jul 28, 2020

Download

Documents

dariahiddleston
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: NebuTech Striving to be nebulizer from Salter SATISFACTION...2. Data on file. Salter Labs; Arvin, CA. 3. Timmons I. Comparison of the efficacy of two nebulizers in treating acute exacerbation

NebuTech® nebulizer from SalterTo help you and your patients

Striving to be

#1 IN PATIENT SATISFACTION

breathe easy

Page 2: NebuTech Striving to be nebulizer from Salter SATISFACTION...2. Data on file. Salter Labs; Arvin, CA. 3. Timmons I. Comparison of the efficacy of two nebulizers in treating acute exacerbation

2

Let NebuTech go to work for you and your patients today.

Performance Versatility Efficiency

NebuTech® nebulizer from Salter

Page 3: NebuTech Striving to be nebulizer from Salter SATISFACTION...2. Data on file. Salter Labs; Arvin, CA. 3. Timmons I. Comparison of the efficacy of two nebulizers in treating acute exacerbation

3

Seconds into Inhalation (1.5 Seconds per Cycle)

Aerosol Delivery NebuTech vs AeroEclipse II

Dens

ity (%

)/Pa

tient

Flo

w (L

PM)

First 250 mL of inhalation 249 ± 40

469 ± 64

73 ± 20

309 ± 33

First One-Third of Inhalation

End of Inhalation

Total Drug Dose (µg/min)

Entire inhalation cycle

00.0 0.5 1.0 1.5

NebuTech AeroEclipse II

NebuTech AeroEclipse II

51015202530354045

DesignInnovative technology makes the difference when choosing the right nebulizer. NebuTech sets itself apart:

• Front-loaded bolus dosing during critical first one-third of each breath1

Performance

Seconds into Inhalation (1.5 Seconds per Cycle)

Aerosol Delivery NebuTech vs AeroEclipse II

Dens

ity (%

)/Pa

tient

Flo

w (L

PM)

First 250 mL of inhalation 249 ± 40

469 ± 64

73 ± 20

309 ± 33

First One-Third of Inhalation

End of Inhalation

Total Drug Dose (µg/min)

Entire inhalation cycle

00.0 0.5 1.0 1.5

NebuTech AeroEclipse II

NebuTech AeroEclipse II

51015202530354045

• Increased drug deposition deep into the lungs1

• High quality of aerosol – 80% of particles in the respirable range (<5 microns)2

Page 4: NebuTech Striving to be nebulizer from Salter SATISFACTION...2. Data on file. Salter Labs; Arvin, CA. 3. Timmons I. Comparison of the efficacy of two nebulizers in treating acute exacerbation

4

PerformanceOutcomesIn two recent large hospital evaluations, NebuTech performed extremely well compared with AeroEclipse II across several critical performance factors1,3:

• Significantly fewer number of patient treatments3

Median Number of Treatments in Emergency Department

Num

ber o

f Tre

atm

ents

2.7NebuTech AeroEclipse II

2.82.93.03.13.23.33.43.53.6

Length of Emergency Department Stay

Hour

s of

ED

Stay

0NebuTech AeroEclipse II

0.51.01.52.02.53.03.5

14.3% fewer patient treatments with NebuTech

3.0

2.53.1

3.5

19.4% reduction in length of stay with NebuTech

Median Number of Treatments in Emergency Department

Num

ber o

f Tre

atm

ents

2.7NebuTech AeroEclipse II

2.82.93.03.13.23.33.43.53.6

Length of Emergency Department Stay

Hour

s of

ED

Stay

0NebuTech AeroEclipse II

0.51.01.52.02.53.03.5

14.3% fewer patient treatments with NebuTech

3.0

2.53.1

3.5

19.4% reduction in length of stay with NebuTech

• Reduced overall length of patient stay,3 which can help reduce per-shift treatment time of healthcare professional

• Helps lower patient readmission rates due to improved drug delivery and home care adaptability1

Page 5: NebuTech Striving to be nebulizer from Salter SATISFACTION...2. Data on file. Salter Labs; Arvin, CA. 3. Timmons I. Comparison of the efficacy of two nebulizers in treating acute exacerbation

5

Treatment Time

Num

ber o

f Min

utes

0NebuTech AeroEclipse II

123456789

10

4

850% shortertreatment time with NebuTech

SpeedTreatment time is important to both you and your patient. In two independent evaluations, NebuTech delivered an advantage compared with other competing products3,4:

• Significantly shorter treatment times, with an average of 4 minutes per treatment3

82%

in less than 3 minutes

• 82% of treatments completed in less than 3 minutes4

Page 6: NebuTech Striving to be nebulizer from Salter SATISFACTION...2. Data on file. Salter Labs; Arvin, CA. 3. Timmons I. Comparison of the efficacy of two nebulizers in treating acute exacerbation

6

PEP

MASK8350

FILTER

Patient-friendly add-on features provide a flexible and improved respiratory experience that is unique to each patient. NebuTech provides unmatched ease of use:

• NebuTech allows for multiple patient settings, options, and positions:

- For ED, acute care, ICU, EMS, and in-home therapy

- Optional mask, filter, and positive expiratory pressure (PEP) therapy

- Allows up to 45-degree angle to accommodate changing postures or flat horizontal position

• Filter option provides RT protection from exhaled medications2

Versatility

Page 7: NebuTech Striving to be nebulizer from Salter SATISFACTION...2. Data on file. Salter Labs; Arvin, CA. 3. Timmons I. Comparison of the efficacy of two nebulizers in treating acute exacerbation

7

NebuTech makes it easy to provide consistency in care:

• Spans the full continuum of patient care:

- Pediatrics to elderly

- Similar product from hospital to home, which helps ensure better patient compliance with treatments

Page 8: NebuTech Striving to be nebulizer from Salter SATISFACTION...2. Data on file. Salter Labs; Arvin, CA. 3. Timmons I. Comparison of the efficacy of two nebulizers in treating acute exacerbation

8

EfficiencyHospitals today not only demand products that deliver improved patient outcomes, they need these results in a cost-efficient manner. NebuTech offers the efficiency you need:

• Less medicine waste with one-way valving2 and closed-chamber system

• More drug to patient faster1,4

• Reduced treatment time1,3,4

• Enhanced productivity and workflow: RT staff saves time for other value-added patient-focused activities1,4

Lower Per-Shift Treatment Time for Required Procedures4

Hour

s Ne

eded

for R

equi

red

Proc

edur

es

0NebuTech VixOne

0.51

1.52

2.53

3.54

4.55

3.6

4.723.4% reduction in per-shift treatment timewith NebuTech

Page 9: NebuTech Striving to be nebulizer from Salter SATISFACTION...2. Data on file. Salter Labs; Arvin, CA. 3. Timmons I. Comparison of the efficacy of two nebulizers in treating acute exacerbation

9

PART NO. UNITS DESCRIPTION

8960-7-50** 50 Disposable nebulizer, mouthpiece, and 7’ supply tube

8980-0-25*** 25 Disposable filter

1301-0-25 25 Salter SafetyTM PEP device with nose clip

1301-0-10 10 Salter SafetyTM PEP device with nose clip

8960-PEP-7-25 25 Disposable nebulizer, mouthpiece, 7’ supply tube, and Salter SafetyTM PEP device with nose clip

PART NO. UNITS DESCRIPTION

8660-7-50** 50 Reusable nebulizer, mouthpiece, and 7’ supply tube

8680-0-25*** 25 Filter only (reusable)

8685-0-1 1 Replacement filter pads (30 filters per bag)

8672-7-25 25 Reusable nebulizer, mouthpiece, 7’ supply tube, and Salter SafetyTM PEP device with nose clip

1301-0-10 10 Salter SafetyTM PEP device with nose clip

NebuTech Ordering Information

Call today for more information or to schedule a NebuTech evaluation. 661-854-3166 • 1-800-421-0024 • 1-800-235-4203

Striving to be

#1 IN PATIENT SATISFACTION

U.S. Patent No. *RE33,717, 5,584,28; **6,176,234 ***Other U.S. and worldwide patents pending.

NebuTech Nebulizer* for Hospitals

NebuTech Nebulizer* for Home

Page 10: NebuTech Striving to be nebulizer from Salter SATISFACTION...2. Data on file. Salter Labs; Arvin, CA. 3. Timmons I. Comparison of the efficacy of two nebulizers in treating acute exacerbation

Printed in U.S.A. SLML-98

100 W. Sycamore Road – Arvin, CA 93203Phone: 661-854-3166, 1-800-421-0024, 1-800-235-4203Fax: 661-854-3850Toll-Free Fax: 1-800-628-4690E-mail: [email protected]

References:1. Misra C. Improved aerosol delivery characteristics of a breath enhanced nebulizer over a breath actuated nebulizer. 2. Data on file. Salter Labs; Arvin, CA. 3. Timmons I. Comparison of the efficacy of two nebulizers in treating acute exacerbation of COPD in the emergency department. Respir Ther. 2013;8(6). In press. 4. Hoisington ER, Chatburn RL, Stoller JK. A comparison of respiratory care workload with 2 different nebulizers. Respir Care. 2009;54(4):495-499.

Looking for a quality and trusted aerosol performance? See how NebuTech can help you, your patients, and your department.

Striving to be

#1 IN PATIENT SATISFACTION

Performance Versatility Efficiency

NebuTech® nebulizer from SalterTo help you and your patients