Date Contents Related Product Software Version
1.00 May 2017 First release MX882117C -
2.00 Oct 2017 Added some test procedure. Added IP Data Transfer test procedure.
MX882117C Ver30.60
Application Note
NB-IoT Measurements Radio Communication Analyzer MT8821C
UE Maximum Output Power for UE category NB1 (6.2.2F) ......................................................... 14 3.1.1. Maximum Power Reduction (MPR) for category NB1 (6.2.3F) .................................................... 16 3.1.2. Configured UE transmitted Output Power for UE category NB1 (6.2.5F) .................................... 18 3.1.3. Minimum Output Power for category NB1 (6.3.2F) ...................................................................... 20 3.1.4. General ON/OFF time mask for category NB1(6.3.4F.1) ............................................................. 22 3.1.5. NPRACH time mask for category NB1 (6.3.4F.2) ......................................................................... 22 3.1.6. Power Control Absolute power tolerance for category NB1 (6.3.5F.1) ......................................... 23 3.1.7. Power Control Relative power tolerance for category NB1 (6.3.5F.2) ......................................... 24 3.1.8. Frequency Error for category NB1 (6.5.1F) .................................................................................. 25 3.1.9.
Error Vector Magnitude (EVM) for category NB1 (NPUSCH) (6.5.2.1F.1) ................................. 26 3.1.10. Error Vector Magnitude (EVM) for category NB1 (NPRACH) (6.5.2.1F.1) ................................. 27 3.1.11. Carrier leakage for category NB1 (6.5.2.2F) .............................................................................. 28 3.1.12. In-band emissions for non allocated RB for category NB1 (6.5.2.3F) ........................................ 29 3.1.13. Occupied bandwidth for category NB1 (6.6.1F) ......................................................................... 31 3.1.14. Spectrum Emission Mask for category NB1 (6.6.2.1F) .............................................................. 32 3.1.15. Adjacent Channel Leakage power Ratio for category NB1 (6.6.2.3F) ....................................... 34 3.1.16. RX Measurements ...................................................................................................................... 36 3.1.17.
Reference sensitivity level for UE category NB1 (7.3F.1) ............................................................ 36 3.2.1. Maximum input level for UE category NB1 (7.4F) ........................................................................ 37 3.2.2.
IP Data Transfer Test ................................................................................................... 38 4. IP DATA TRANSFER TEST FOR CATEGORY NB1 ....................................................................................... 38 4.1.
Connection Diagram ................................................................................................................... 38 4.1.1. Application Server Connection and Setting .............................................................................. 40 4.1.2. Client PC Connection and Setting .............................................................................................. 45 4.1.3. Initial Condition Setting .............................................................................................................. 45 4.1.4. Location Registration and Packet Connection .......................................................................... 47 4.1.5. TCP/UDP Throughput .................................................................................................................. 50 4.1.6.
IP DATA APPLICATION ............................................................................................................................ 51 4.2. ping ............................................................................................................................................... 51 4.2.1.
3800 to 5000 MHz (Can be used when installing MT8821C-019 option)
For frequencies below 500 MHz, only the following range meets the specifications:
452.5 to 457.5 MHz (LTE OperatingBand31)
Input level –60 to +35 dBm (Main1/2)
Measurement accuracy ±0.5 dB (–20 to +35 dBm) typ. ±0.3 dB (–20 to +35 dBm) ±0.7 dB (–50 to –20 dBm) ±0.9 dB (–60 to –50 dBm) 400 MHz ≤ Freq. ≤ 3800 MHz 10° to 40°C after calibration
±0.7 dB (–20 to +35 dBm) ±0.9 dB (–50 to –20 dBm) ±1.1 dB (–60 to –50 dBm) 3800 MHz <freq.≤ 5000 MHz 20° to 30°C after calibration
Linearity ±0.2 dB (–40 to 0 dB, ≥–50 dBm) ±0.4 dB (–40 to 0 dB, ≥–60 dBm) 400 to 5000 MHz
7.8.1F Wide band Intermodulation for UE category NB1 Requires External Equipment √*1
√√: Supported | √: Requires external equipment (SPA or SG) | −: Measure by SPA | : Future Support | X: No Support *1: This application note does not explain measurement procedures for appropriate test items.
8
1.3 Operation Bands The MT8821C supports Operation bands 1 to 14, 17 to 46, 65 to 67, 250, 252 and 255.
Table 1.3-1 E-UTRA Channel Numbers and Default UE TX-RX Frequency Separation
(From 3GPP TS36.101 Table 5.7.3-1 and Table 5.7.4-1)
*1: The MT8821C-019 option must be installed in the MT8821C to use operation bands 252 and 255. *2: The TDD band is not supported (under consideration).
10
2. Basic Operations The following test procedures can be used for the MT8821C.
2.1 Connection Diagram
Figure 1.1.1-1 Connection Diagram for Tx and Rx Test (MT8821C)
2.2 Initial Condition Setting This sets the initial condition before measurement. The following test configuration example shows the settings when Operating Band is 1 (UL Channel is 18300, DL Channel is 300), Coexisting Bandwidth is 5 MHz. Adjust the measurement channel and NB Operation Mode to match the test case.
1. Execute PRESET to set default parameter. 2. Execute ULCHAN 18300 to set Common Parameter - Frequency - UL Channel and DL Channel to 18300
and 300, respectively. [NB-Operation Mode is Stand-alone]
3. Execute NBOPEMODE STANDALONE to set Common Parameter - General – NB Operation Mode to Stand-alone
[NB-Operation Mode is Guard-band]
3. Execute NBOPEMODE GUARDBAND to set Common Parameter – General – NB Operation Mode to Guard-band.
4. Execute COEXBANDWIDTH 5MHZ to set Common Parameter - Frequency - Coexisting Bandwidth to 5 MHz.
[NB-Operation Mode is In-band-Same PCI]
3. Execute NBOPEMODE INBAND_SAMEPCI to set Common Parameter - General – NB Operation Mode to In-band-Same PCI.
4. Execute COEXBANDWIDTH 5MHZ to set Common Parameter - Frequency - Coexisting Bandwidth to 5 MHz.
[NB-Operation Mode is In-band-Different PCI]
3. Execute NBOPEMODE INBAND_DIFFPCI to set Common Parameter - General – NB Operation Mode to In-band-Different PCI.
4. Execute COEXBANDWIDTH 5MHZ to set Common Parameter - Frequency - Coexisting Bandwidth to 5 MHz.
2.3 Location Registration and Test Mode Connection This performs UE location registration after setting the initial conditions. After UE location registration, the UE will connect to the Test Mode autonomously.
1. Connect UE and MT8821C. 2. Execute CALLPROC ON to set Common Parameter - Call processing to On.
11
3. Execute CALLSO to clear call processing status. 4. Execute CALLSTAT? to confirm the call processing status is 1 (= Idle). 5. Turn on UE power. 6. Execute CALLSTATIC? to confirm the call processing stationary status is 6 (= Connected). 7. Repeat step 6 when the checked status is not 6 (= Connected).
12
2.4 Test Mode Disconnection After connecting to the Test Mode, disconnection is performed if necessary.
1. Execute CALLSO to disconnect from Test Mode. 2. Execute CALLSTATIC? to confirm the call processing stationary status is 1 (= Idle (Regist)).
2.5 Broadcast Information Update When changing broadcast information, the UE must be notified of the change using the following methods.
A) Turn UE power OFF and ON Turn the UE power OFF and ON to update the broadcast information.
1. Disconnect Test Mode (2.4). 2. Turn off UE power. 3. Turn on UE power. 4. Execute CALLSTATIC? to confirm the call processing status is 6 (= Connected).
Repeat steps 4 when the checked status is not 6 (= Connected).
NOTE 1: This procedure is required to update the broadcast information.
13
3. TRX Measurements (Fundamental Measurements) This chapter describes how to test TRX measurement using GPIB remote control software commands. For details of GPIB commands and manual operation, refer to the NB-IoT operation manual. GPIB commands are in red bold. At Normal UE, the UE power class is assumed to be Class 3. Before starting TRX measurement, do the following to ensure the call processing status is connected.
1. Initial Condition Setting (2.2) 2. Broadcast Information Update (2.5) 3. Location Registration (2.3) 4. Test Mode Connection (2.3)
Then, set the average count for each measurement items to 20 times, except for special conditions.
3.1 TX Measurements The following measurement example assumes Operating Band is 1, and Test Frequency is Mid range.
UE Maximum Output Power for UE category NB1 (6.2.2F) 3.1.1. This chapter describes UL measurement examples when (Modulation, Ntones, Subcarrier Spacing) is (BPSK, 1@0 1@47, 3.75 kHz), (QPSK, 1@0 1@11, 15 kHz) or (QPSK, 3@3) .
1. Execute PWR_MEAS ON to set Power measurement to ON. 2. Execute PWR_AVG 20 to set the average count of Power measurement to 20 times. 3. Execute ILVL 30.0 to set Input Level to +30 dBm. 4. Execute OLVL -74 to set Output Level to -74 dBm. 5. Execute DLIMCS1 -1 to set DL RMC – MCS Index to N/A.
[(BPSK, 1@0 1@47, 3.75 kHz) measurements]
6. Execute ULSC_SPACE 3.75KHZ to set UL RMC Subcarrier Spacing to 3.75 kHz. 7. Execute ULRMC_SC 1 to set UL RMC – Number of Subcarrier to 1. 8. Execute ULSC_START 0 to set UL RMC – Starting Subcarrier to 0. 9. Execute ULIMCS 0 to set UL RMC – MCS Index to 0.
10. Execute ULRMC_RU 2 to set UL RMC – Number of Resource Units to 2. 11. Update Broadcast Information (2.5) 12. Execute SWP to measure the power. 13. Execute POWER? AVG to read the TX power measurement result. 14. Confirm the measurement result is 23 dBm (Tolerance +2.7/-2.7 dB). 15. Execute ULSC_START 47 to set UL RMC – Starting Subcarrier to 47. 16. Update Broadcast Information (2.5) 17. Execute steps 12 to 14. [(QPSK, 1@0 1@11, 15 kHz) measurements] 18. Execute ULSC_SPACE 15KHZ to set ULSC_SPACE Subcarrier Spacing to 15 kHz. 19. Execute ULRMC_SC 1 to set UL RMC - Number of Subcarrier to 1. 20. Execute ULSC_START 0 to set UL RMC – Starting Subcarrier to 0. 21. Execute ULIMCS 3 to set UL RMC – MCS Index to 3. 22. Execute ULRMC_RU 1 to set UL RMC – Number of Resource Units to 1. 23. Update Broadcast Information (2.5) 24. Execute steps 12 to 14. 25. Execute ULSC_START 11 to set UL RMC – Starting Subcarrier to 11. 26. Update Broadcast Information (2.5) 27. Execute steps 12 to 14. [(QPSK, 3@3, 15 kHz) measurements] 28. Execute ULSC_SPACE 15KHZ to set ULSC_SPACE Subcarrier Spacing to 15 kHz. 29. Execute ULSC_START 3 to set UL RMC – Starting Subcarrier to 3. 30. Execute ULRMC_SC 3 to set UL RMC - Number of Subcarrier to 3. 31. Execute ULIMCS 5 to set UL RMC – MCS Index to 5. 32. Update Broadcast Information (2.5)
14
33. Execute steps 12 to 14.
NOTE 1: In this example, the Pass/Fail evaluation value is set to the Band 1 default value described in TS36.521-1. Since the evaluation value differs according to the Band, refer to the evaluation value described in TS36.521-1 Table 6.2.2F.3-1.
Figure 3.1.1-1 Example of Measurement Result (5 MHz band)
15
Maximum Power Reduction (MPR) for category NB1 (6.2.3F) 3.1.2. This chapter describes UL measurement examples when (Modulation, Ntones, Subcarrier Spacing) is (QPSK, 1@0 1@47, 3.75 kHz), (BPSK, 1@0 1@11, 15 kHz), (QPSK, 3@0, 3@3, 3@9, 15 kHz), (QPSK, 6@0, 6@6, 15 kHz) or (QPSK, 12@0, 15 kHz).
1. Execute PWR_MEAS ON to set Power measurement to ON. 2. Execute PWR_AVG 20 to set the average count of Power measurement to 20 times. 3. Execute ILVL 30.0 to set Input Level to +30 dBm. 4. Execute OLVL -74 to set Output Level to -74 dBm. 5. Execute DLIMCS1 -1 to set DL RMC – MCS Index to N/A.
[(QPSK, 1@0 1@47, 3.75kHz) measurements]
6. Execute ULSC_SPACE 3.75KHZ to set UL RMC Subcarrier Spacing to 3.75 kHz. 7. Execute ULRMC_SC 1 to set UL RMC – Number of Subcarrier to 1. 8. Execute ULSC_START 0 to set UL RMC – Starting Subcarrier to 0. 9. Execute ULIMCS 3 to set UL RMC – MCS Index to 3.
10. Update Broadcast Information (2.5) 11. Execute SWP to measure the power. 12. Execute POWER? AVG to read the TX power measurement result. 13. Confirm the measurement result is 23 dBm (Upper limit 25.7 dBm/Lower limit 19.3 dBm). 14. Execute ULSC_START 47 to set UL RMC – Starting Subcarrier to 47. 15. Update Broadcast Information (2.5) 16. Execute steps 11 to 13. [(BPSK, 1@0 1@11, 15 kHz) measurements] 17. Execute ULSC_SPACE 15KHZ to set UL RMC Subcarrier Spacing to 15 kHz. 18. Execute ULRMC_SC 1 to set UL RMC - Number of Subcarrier to 1. 19. Execute ULSC_START 0 to set UL RMC – Starting Subcarrier to 0. 20. Execute ULIMCS 0 to set UL RMC – MCS Index to 0. 21. Execute ULRMC_RU 2 to set UL RMC – Number of Resource Units to 2. 22. Update Broadcast Information (2.5) 23. Execute SWP to measure the power. 24. Execute POWER? AVG to read the TX power measurement result. 25. Confirm the measurement result is 23 dBm (Upper limit 25.7 dBm/Lower limit 20.3 dBm). 26. Execute ULSC_START 11 to set UL RMC – Starting Subcarrier to 11. 27. Update Broadcast Information (2.5) 28. Execute steps 23 to 25. [(QPSK, 3@0 3@3 3@9, 15 kHz) measurements] NOTE 1 29. Execute ULSC_SPACE 15KHZ to set UL RMC Subcarrier Spacing to 15 kHz. 30. Execute ULRMC_SC 3 to set UL RMC - Number of Subcarrier to 3. 31. Execute ULSC_START 0 to set UL RMC – Starting Subcarrier to 0. 32. Execute ULIMCS 5 to set UL RMC – MCS Index to 5. 33. Execute ULRMC_RU 1 to set UL RMC – Number of Resource Units to 1. 34. Update Broadcast Information (2.5) 35. Execute SWP to measure the power. 36. Execute POWER? AVG to read the TX power measurement result. 37. Confirm the measurement result is 22.5 dBm (Upper limit 25.7 dBm/Lower limit 19.8 dBm). 38. Execute ULSC_START 3 to set UL RMC – Starting Subcarrier to 3. 39. Update Broadcast Information (2.5) 40. Execute steps 35 to 37. 41. Confirm the measurement result is 23 dBm (Upper limit 25.7 dBm/Lower limit 20.3 dBm). 42. Execute ULSC_START 9 to set UL RMC – Starting Subcarrier to 9. 43. Update Broadcast Information (2.5) 44. Execute steps 35 to 37. [(QPSK, 6@0 6@6, 15 kHz) measurements] NOTE 1 45. Execute ULSC_SPACE 15KHZ to set UL RMC Subcarrier Spacing to 15 kHz.
16
46. Execute ULRMC_SC 6 to set UL RMC - Number of Subcarrier to 6. 47. Execute ULSC_START 0 to set UL RMC – Starting Subcarrier to 0. 48. Execute ULIMCS 5 to set UL RMC – MCS Index to 5. 49. Update Broadcast Information (2.5) 50. Execute SWP to measure the power. 51. Execute POWER? AVG to read the TX power measurement result. 52. Confirm the measurement result is 22 dBm (Upper limit 25.7 dBm/Lower limit 19.3 dBm). 53. Execute ULSC_START 6 to set UL RMC – Starting Subcarrier to 6. 54. Update Broadcast Information (2.5) 55. Execute steps 50 to 52. [(QPSK, 12@0, 15 kHz) measurements] NOTE 1 56. Execute ULSC_SPACE 15KHZ to set UL RMC Subcarrier Spacing to 15 kHz. 57. Execute ULRMC_SC 12 to set UL RMC - Number of Subcarrier to 12. 58. Execute ULSC_START 0 to set UL RMC – Starting Subcarrier to 0. 59. Execute ULIMCS 5 to set UL RMC – MCS Index to 5. 60. Update Broadcast Information (2.5) 61. Execute SWP to measure the power. 62. Execute POWER? AVG to read the TX power measurement result. 63. Confirm the measurement result is 21 dBm (Upper limit 25.7 dBm/Lower limit 18.3 dBm).
NOTE 1: Applicable to UE supporting UL multi-tone transmissions. NOTE 2: In this example, the Pass/Fail evaluation value is set to the Band 1 default value described in
TS36.521-1. Since the evaluation value differs according to the Band, set the evaluation value described in TS36.521-1 Table 6.2.3F.5-1.
Figure 3.1.2-1 Example of Measurement Result
17
Configured UE transmitted Output Power for UE category NB1 (6.2.5F) 3.1.3. This chapter describes a UL measurement example when (Modulation, Ntones, Subcarrier Spacing) is (QPSK, 1@0 1@47, 3.75 kHz), (QPSK, 1@0 1@11, 15 kHz) or (QPSK, 12@0, 15 kHz).
1. Execute PWR_MEAS ON to set Power measurement to ON. 2. Execute PWR_AVG 20 to set the average count of Power measurement to 20 times. 3. Execute ILVL 30.0 to set Input Level to +30 dBm. 4. Execute OLVL -74 to set Output Level to -74 dBm. 5. Execute DLIMCS1 -1 to set DL RMC – MCS Index to N/A.
[(QPSK, 1@0, 1@47, 3.75 kHz) measurements]
6. Execute ULSC_SPACE 3.75KHZ to set UL RMC Subcarrier Spacing to 3.75 kHz. 7. Execute ULRMC_SC 1 to set UL RMC – Number of Subcarrier to 1. 8. Execute ULSC_START 0 to set UL RMC – Starting Subcarrier to 0. 9. Execute ULIMCS 3 to set UL RMC – MCS Index to 3.
10. Execute MAXULPWR -10 to set p-Max to -10. 11. Execute ILVL -2.3 to set Input Level to -2.3 dBm. 12. Update Broadcast Information (2.5) 13. Execute SWP to measure power. 14. Execute POWER? AVG to read the TX Power measurement result. 15. Confirm the measurement result is -10 dBm (Tolerance +7.7/-7.7 dB). 16. Execute MAXULPWR 10 to set p-Max to 10. 17. Execute ILVL 16.7 to set Input Level to 16.7 dBm. 18. Update Broadcast Information (2.5) 19. Execute steps 13 to 14. 20. Confirm the measurement result is 10 dBm (Tolerance +6.7/-6.7 dB). 21. Execute MAXULPWR 15 to set p-Max to 15. 22. Execute ILVL 20.7 to set Input Level to 20.7 dBm. 23. Update Broadcast Information (2.5) 24. Execute steps 13 to 14. 25. Confirm the measurement result is 15 dBm (Tolerance +5.7/-5.7 dB). 26. Execute ULSC_START 47 to set UL RMC – Starting Subcarrier to 47. 27. Execute steps 10 to 25. [(QPSK, 1@0, 1@11, 15 kHz) measurements] 28. Execute ULSC_SPACE 15KHZ to set UL RMC Subcarrier Spacing to 15 kHz. 29. Execute ULRMC_SC 1 to set UL RMC – Number of Subcarrier to 1. 30. Execute ULSC_START 0 to set UL RMC – Starting Subcarrier to 0. 31. Execute ULIMCS 3 to set UL RMC – MCS Index to 3. 32. Execute MAXULPWR -10 to set p-Max to -10. 33. Execute ILVL -2.3 to set Input Level to -2.3 dBm. 34. Update Broadcast Information (2.5) 35. Execute SWP to measure power. 36. Execute POWER? AVG to read the TX Power measurement result. 37. Confirm the measurement result is -10 dBm (Tolerance +7.7/-7.7 dB). 38. Execute MAXULPWR 10 to set p-Max to 10. 39. Execute ILVL 16.7 to set Input Level to 16.7 dBm. 40. Update Broadcast Information (2.5) 41. Execute steps 35 to 36. 42. Confirm the measurement result is 10 dBm (Tolerance +6.7/-6.7 dB). 43. Execute MAXULPWR 15 to set p-Max to 15. 44. Execute ILVL 20.7 to set Input Level to 20.7 dBm. 45. Update Broadcast Information (2.5) 46. Execute steps 35 to 36. 47. Confirm the measurement result is 15 dBm (Tolerance +5.7/-5.7 dB). 48. Execute ULSC_START 11 to set UL RMC – Starting Subcarrier to 11. 49. Execute steps 32 to 47.
18
[(QPSK, 12@0, 15 kHz) measurements] NOTE1 50. Execute ULSC_SPACE 15KHZ to set UL RMC Subcarrier Spacing to 15 kHz. 51. Execute ULRMC_SC 12 to set UL RMC – Number of Subcarrier to 12. 52. Execute ULSC_START 0 to set UL RMC – Starting Subcarrier to 0. 53. Execute ULIMCS 5 to set UL RMC – MCS Index to 5. 54. Execute MAXULPWR -10 to set p-Max to -10. 55. Execute ILVL -2.3 to set Input Level to -2.3 dBm. 56. Update Broadcast Information (2.5) 57. Execute SWP to measure power. 58. Execute POWER? AVG to read the TX Power measurement result. 59. Confirm the measurement result is -10 dBm (Tolerance +7.7/-7.7 dB). 60. Execute MAXULPWR 10 to set p-Max to 10. 61. Execute ILVL 16.7 to set Input Level to 16.7 dBm. 62. Update Broadcast Information (2.5) 63. Execute steps 57 to 58. 64. Confirm the measurement result is 10 dBm (Tolerance +6.7/-6.7 dB). 65. Execute MAXULPWR 15 to set p-Max to 15. 66. Execute ILVL 20.7 to set Input Level to 20.7 dBm. 67. Update Broadcast Information (2.5) 68. Execute steps 57 to 58.
NOTE 1: Applicable to UE supporting UL multi-tone transmissions NOTE 2: Change the Pass/Fail evaluation value as described in TS36.521-1. In this example, the value is set
when the Carrier Frequency is 3 GHz or less. When the Carrier Frequency exceeds 3 GHz, refer to the evaluation value to TS36.521-1 Table 6.2.5F.5-1.
Figure 3.1.3-1 Example of Measurement Result
19
Minimum Output Power for category NB1 (6.3.2F) 3.1.4. This chapter describes a UL measurement example when (Modulation, Ntones, Subcarrier Spacing) is (BPSK, 1@0 1@47, 3.75 kHz), (QPSK, 1@0 1@11, 15 kHz) or (QPSK, 12@0, 15 kHz).
1. Execute PWR_MEAS ON to set Power measurement to ON. 2. Execute PWR_AVG 20 to set the average count of Power measurement to 20 times. 3. Execute ILVL -30.0 to set Input Level to -30 dBm. 4. Execute OLVL -74 to set Output Level to -74 dBm. 5. Execute DLIMCS1 -1 to set DL RMC – MCS Index to N/A.
[(BPSK 1@0, 3.75kHz) measurements] NOTE 2
6. Execute ULSC_SPACE 3.75KHZ to set UL RMC Subcarrier Spacing to 3.75 kHz. 7. Execute ULRMC_SC 1 to set UL RMC - Number of Subcarrier to 1. 8. Execute ULSC_START 0 to set UL RMC – Starting Subcarrier to 0. 9. Execute ULIMCS 0 to set UL RMC – MCS Index to 0.
10. Execute ULRMC_RU 2 to set UL RMC – Number of Resource Units to 2. 11. Execute NRSPWR -55 to set nrs-Power to -55. 12. Execute P0_NOMNPUSCH -95 to set p0-NominalNPUSCH to -95. 13. Update Broadcast Information (2.5) 14. Execute SWP to measure the power. 15. Execute CHPWR? AVG to read the Channel Power measurement result. 16. Confirm the measurement result is less than -39 dBm. [(BPSK 1@47, 3.75kHz) measurements] NOTE 3 17. Execute ULSC_START 47 to set UL RMC – Starting Subcarrier to 47. 18. Update Broadcast Information (2.5) 19. Execute steps 14 to 16. [(QPSK 1@0, 15kHz) measurements] NOTE 2 20. Execute ULSC_SPACE 15KHZ to set UL RMC Subcarrier Spacing to 15 kHz. 21. Execute ULRMC_SC 1 to set UL RMC - Number of Subcarrier to 1. 22. Execute ULSC_START 0 to set UL RMC – Starting Subcarrier to 0. 23. Execute ULIMCS 3 to set UL RMC – MCS Index to 3. 24. Execute ULRMC_RU 1 to set UL RMC – Number of Resource Units to 1. 25. Execute NRSPWR -55 to set nrs-Power to -55. 26. Execute P0_NOMNPUSCH -95 to set p0-NominalNPUSCH to -95. 27. Update Broadcast Information (2.5) 28. Execute SWP to measure the power. 29. Execute CHPWR? AVG to read the Channel Power measurement result. 30. Confirm the measurement result is less than -39 dBm. [(QPSK 1@11, 15kHz) measurements] NOTE 3 31. Execute ULSC_START 11 to set UL RMC – Starting Subcarrier to 11. 32. Update Broadcast Information (2.5) 33. Execute steps 28 to 30. [(QPSK 12@0, 15kHz) measurements] NOTE 1 34. Execute ULSC_SPACE 15KHZ to set UL RMC Subcarrier Spacing to 15 kHz. 35. Execute ULRMC_SC 12 to set UL RMC - Number of Subcarrier to 12. 36. Execute ULSC_START 0 to set UL RMC – Starting Subcarrier to 0. 37. Execute ULIMCS 5 to set UL RMC – MCS Index to 5. 38. Execute NRSPWR -55 to set nrs-Power to -55. 39. Execute P0_NOMNPUSCH -95 to set p0-NominalNPUSCH to -95. 40. Update Broadcast Information (2.5) 41. Execute SWP to measure the power. 42. Execute CHPWR? AVG to read the Channel Power measurement result. 43. Confirm the measurement result is less than -39 dBm.
20
NOTE 1: Applicable to UE supporting UL multi-tone transmissions. NOTE 2: Only applicable for low range. NOTE 3: Only applicable for high range.
Figure 3.1.4-1 Example of Measurement Result
21
General ON/OFF time mask for category NB1(6.3.4F.1) 3.1.5.
1. Execute MEASITEM PWRTEMP to set Main Screen to NPUSCH Power Template. 2. Execute ILVL 30.0 to set Input Level to 30 dBm. 3. Execute OLVL -74 to set Output Level to –74 dBm. 4. Execute DLIMCS1 -1 to set DL RMC – MCS Index to N/A. 5. Execute ULSC_SPACE 15KHZ to set UL RMC Subcarrier Spacing to 15 kHz. 6. Execute ULRMC_SC 1 to set UL RMC - Number of Subcarrier to 1. 7. Update Broadcast Information (2.5) 8. Execute SWP to measure power. 9. Execute ONPWR? AVG to read the On Power measurement result.
10. Confirm the measurement result is 23 dBm (Upper limit 25.7 dBm/Lower limit 19.3 dBm). 11. Execute OFFPWR_BEFORE? AVG to read the Off Power (Before) measurement result. 12. Confirm the measurement result is less than –48.5 dBm. 13. Execute OFFPWR_AFTER? AVG to read the Off Power (After) measurement result. 14. Confirm the measurement result is less than –48.5 dBm.
NPRACH time mask for category NB1 (6.3.4F.2) 3.1.6. This chapter describes a NPRACH measurement example.
1. Execute MEASITEM NPRACH to set Measurement Item to NPRACH. 2. Execute NPRACH 1 to set NPRACH preamble format to 1. 3. Execute ILVL 30.0 to set Input Level to 30 dBm. 4. Execute OLVL -74 to set Output Level to -74 dBm. 5. Execute DLIMCS1 -1 to set DL RMC – MCS Index to N/A.
[On Power Measurement]
6. Turn on UE power. 7. Execute CALLSO to clear call processing status. 8. Execute CALLSTAT? to confirm the call processing status is 1 (= Idle). 9. Execute SWPANDPG when call processing is Idle (Regist) and SWP when Connected to measure Power
Template (PRACH). 10. Execute ONPWR? AVG to read the On Power measurement result. 11. Confirm the measurement result is 23 dBm (Upper limit 25.7 dBm/Lower limit 19.3 dBm). [Off Power measurement] 12. Execute ILVL -10.0 to set Input Level to -10 dBm. 13. Execute CALLSO to clear call processing status. 14. Execute CALLSTAT? to confirm the call processing status is 1 (= Idle). 15. Execute SWPANDPG when call processing is Idle (Regist) and SWP when Connected to measure Power
Template (PRACH). 16. Execute OFFPWR_AFTER? AVG to read the Off Power (After) measurement result. 17. Confirm the measurement result is less than -48.5 dBm.
22
Power Control Absolute power tolerance for category NB1 (6.3.5F.1) 3.1.7.
This chapter describes a UL measurement example when (Modulation, Ntones, Subcarrier Spacing) is (QPSK, 1@0, 3.75 kHz), (QPSK, 1@0, 15 kHz) or (QPSK, 12@0, 15 kHz).
1. Execute MEASITEM PCT to set Measurement Item to Power Control Tolerance. 2. Execute ILVL 10.0 to set Input Level to 10 dBm. 3. Execute OLVL -74 to set Output Level to -74 dBm. 4. Execute DLIMCS1 -1 to set DL RMC – MCS Index to N/A. 5. Execute PCT_TYPE ABS to set Power Control Tolerance to Absolute Power.
[Test point 1] [(QPSK, 1@0, 3.75 kHz) measurements]
6. Execute ULSC_SPACE 3.75KHZ to set UL RMC Subcarrier Spacing to 3.75 kHz. 7. Execute ULRMC_SC 1 to set UL RMC – Number of Subcarrier to 1. 8. Execute ULSC_START 0 to set UL RMC – Starting Subcarrier to 0. 9. Execute ULIMCS 3 to set UL RMC – MCS Index to 3.
10. Execute NRSPWR 20 to set nrs-Power to 20. 11. Execute P0_NOMNPUSCH -124 to set p0-NominalNPUSCH to -124. 12. Update Broadcast Information (2.5) 13. Execute SWP to measure power. 14. Execute PCTPWR? to read the Absolute Power (dBm) measurement result. 15. Confirm the measurement result is -25 dBm (Tolerance +10.0/-10.0 dB). [(QPSK, 1@0, 15 kHz) measurements] 16. Execute ULSC_SPACE 15KHZ to set UL RMC Subcarrier Spacing to 15 kHz. 17. Execute ULRMC_SC 1 to set UL RMC – Number of Subcarrier to 1. 18. Execute ULSC_START 0 to set UL RMC – Starting Subcarrier to 0. 19. Execute ULIMCS 3 to set UL RMC – MCS Index to 3. 20. Update Broadcast Information (2.5) 21. Execute SWP to measure power. 22. Execute PCTPWR? to read the Absolute Power (dBm) measurement result. 23. Confirm the measurement result is -19 dBm (Tolerance +10.0/-10.0 dB). [(QPSK, 12@0, 15 kHz) measurements] NOTE 1 24. Execute ULRMC_SC 12 to set UL RMC - Number of Subcarrier to 12. 25. Execute ULIMCS 5 to set UL RMC – MCS Index to 5. 26. Update Broadcast Information (2.5) 27. Execute SWP to measure power. 28. Execute PCTPWR? to read the Absolute Power (dBm) measurement result. 29. Confirm the measurement result is -8.2 dBm (Tolerance +10.0/-10.0 dB). [Test point 2] [(QPSK, 1@0, 3.75 kHz) measurements]
1. Execute ULSC_SPACE 3.75KHZ to set UL RMC Subcarrier Spacing to 3.75 kHz. 2. Execute ULRMC_SC 1 to set UL RMC – Number of Subcarrier to 1. 3. Execute ULSC_START 0 to set UL RMC – Starting Subcarrier to 0. 4. Execute ULIMCS 3 to set UL RMC – MCS Index to 3. 5. Execute NRSPWR 3 to set nrs-Power to 3. 6. Execute P0_NOMNPUSCH -94 to set p0-NominalNPUSCH to -94. 7. Update Broadcast Information (2.5) 8. Execute SWP to measure power. 9. Execute PCTPWR? to read the Absolute Power (dBm) measurement result.
10. Confirm the measurement result is -12 dBm (Tolerance +10.0/-10.0 dB). [(QPSK, 1@0, 15 kHz) measurements] 11. Execute ULSC_SPACE 15KHZ to set UL RMC Subcarrier Spacing to 15 kHz.
23
12. Execute steps 8 to 33. 13. Execute ULRMC_SC 1 to set UL RMC – Number of Subcarrier to 1. 14. Execute ULSC_START 0 to set UL RMC – Starting Subcarrier to 0. 15. Execute ULIMCS 3 to set UL RMC – MCS Index to 3. 16. Update Broadcast Information (2.5) 17. Execute SWP to measure power. 18. Execute PCTPWR? to read the Absolute Power (dBm) measurement result. 19. Confirm the measurement result is -6 dBm (Tolerance +10.0/-10.0 dB). [(QPSK, 12@0, 15 kHz) measurements] NOTE1 20. Execute ULRMC_SC 12 to set UL RMC - Number of Subcarrier to 12. 21. Execute ULIMCS 5 to set UL RMC – MCS Index to 5. 22. Update Broadcast Information (2.5) 23. Execute SWP to measure power. 24. Execute PCTPWR? to read the Absolute Power (dBm) measurement result. 25. Confirm the measurement result is 4.8 dBm (Tolerance +10.0/-10.0 dB).
Power Control Relative power tolerance for category NB1 (6.3.5F.2) 3.1.8. *This is not supported yet. It will be supported in future.
24
Frequency Error for category NB1 (6.5.1F) 3.1.9. This chapter describes UL measurement examples when (Modulation, Ntones, Subcarrier Spacing) is (QPSK, 1@0, 3.75kHz), (QPSK, 1@0 15kHz), (QPSK, 3@0 15kHz), (QPSK, 6@0 15kHz) or (QPSK, 12@0 15kHz).
1. Execute MOD_MEAS ON to set Modulation analysis to ON. 2. Execute MOD_AVG 20 to set the average count of Modulation Analysis to 20 times. 3. Execute ILVL 30.0 to set Input Level to +30 dBm. 4. Execute OLVL -101.5 to set Output Level to -101.5 dBm.
[(QPSK, 1@0 3.75 kHz) measurements]
5. Execute ULSC_SPACE 3.75KHZ to set UL RMC Subcarrier Spacing to 3.75 kHz. 6. Execute ULRMC_SC 1 to set UL RMC - Number of Subcarrier to 1. 7. Execute ULIMCS 3 to set UL RMC – MCS Index to 3. 8. Execute DLIMCS1 4 to set DL RMC – MCS Index to 4. 9. Update Broadcast Information (2.5)
10. Execute SWP to perform Modulation Analysis measurement. 11. Execute WORST_CARRFERR? HZ to read the Carrier Frequency Error (Hz) measurement result. 12. Execute WORST_CARRFERR? PPM to read the Carrier Frequency Error (ppm) measurement result. 13. Confirm the measurement result is less than (0.1 PPM + 15Hz) [(QPSK, 1@0 15 kHz) measurements] 14. Execute ULSC_SPACE 15KHZ to set UL RMC Subcarrier Spacing to 15 kHz. 15. Update Broadcast Information (2.5) 16. Execute steps 9 to 13. [(QPSK, 3@0 15 kHz) measurements] NOTE 1 17. Execute ULRMC_SC 3 to set UL RMC - Number of Subcarrier to 3. 18. Execute ULIMCS 5 to set UL RMC – MCS Index to 5. 19. Update Broadcast Information (2.5) 20. Execute steps 9 to 13. [(QPSK, 6@0 15 kHz) measurements] NOTE 1 21. Execute ULRMC_SC 6 to set UL RMC - Number of Subcarrier to 6. 22. Execute ULIMCS 5 to set UL RMC – MCS Index to 5. 23. Update Broadcast Information (2.5) 24. Execute steps 9 to 13. [(QPSK, 12@0 15 kHz) measurements] NOTE 1 25. Execute ULRMC_SC 12 to set UL RMC - Number of Subcarrier to 12. 26. Execute ULIMCS 5 to set UL RMC – MCS Index to 5. 27. Update Broadcast Information (2.5) 28. Execute steps 9 to 13.
NOTE 1: Applicable to UE supporting UL multi-tone transmissions.
Figure 3.1.9-1 Example of Measurement Result
25
Error Vector Magnitude (EVM) for category NB1 (NPUSCH) (6.5.2.1F.1) 3.1.10. This chapter describes UL measurement examples when (Modulation, Ntones, Sub-carrier spacing) is (QPSK, 1@0, 1@47, 3.75 kHz), (QPSK, 1@0 1@11, 15 kHz) or (QPSK, 12@0, 15kHz).
1. Execute MOD_MEAS ON to set Modulation analysis to ON. 2. Execute MOD_AVG 20 to set the average count of Modulation Analysis to 20 times. 3. Execute OLVL_EPRE -110 to set Output Level to -110 dBm/15 kHz. 4. Execute DLIMCS1 -1 to set DL RMC – MCS Index to N/A.
[Test point 1] [(QPSK, 1@0 1@47, 3.75 kHz) measurements]
5. Execute ULSC_SPACE 3.75KHZ to set UL RMC Subcarrier Spacing to 3.75 kHz. 6. Execute ULRMC_SC 1 to set UL RMC - Number of Subcarrier to 1. 7. Execute ULSC_START 0 to set UL RMC – Starting Subcarrier to 0. 8. Execute ULIMCS 3 to set UL RMC – MCS Index to 3. 9. Execute ILVL 30.0 to set Input Level to +30 dBm.
10. Update Broadcast Information (2.5) 11. Wait about 200ms until the UE power becomes the maximum output power. 12. Execute SWP to measure Modulation Analysis. 13. Execute EVM? AVG to read the EVM measurement result. 14. Confirm the measurement result is less than 17.5%. 15. Execute RSEVM? AVG to read the Reference Signal EVM measurement result. 16. Confirm the measurement result is less than 17.5%. 17. Execute ULSC_START 47 to set UL RMC – Starting Subcarrier to 47. 18. Update Broadcast Information (2.5) 19. Execute steps 11 to 16 [(QPSK, 1@0 1@11, 15 kHz) measurements] 20. Execute ULSC_SPACE 15KHZ to set UL RMC Subcarrier Spacing to 15 kHz. 21. Execute ULRMC_SC 1 to set UL RMC - Number of Subcarrier to 1. 22. Execute ULSC_START 0 to set UL RMC – Starting Subcarrier to 0. 23. Execute ULIMCS 3 to set UL RMC – MCS Index to 3. 24. Update Broadcast Information (2.5) 25. Execute steps 11 to 16. 26. Execute ULSC_START 11 to set UL RMC – Starting Subcarrier to 11. 27. Update Broadcast Information (2.5) 28. Execute steps 11 to 16. [(QPSK, 12@0, 15 kHz) measurements] NOTE 1 29. Execute ULSC_SPACE 15KHZ to set UL RMC Subcarrier Spacing to 15 kHz. 30. Execute ULRMC_SC 12 to set UL RMC - Number of Subcarrier to 12. 31. Execute ULSC_START 0 to set UL RMC – Starting Subcarrier to 0. 32. Execute ULIMCS 5 to set UL RMC – MCS Index to 5. 33. Update Broadcast Information (2.5) 34. Execute steps 11 to 16. [Test point 2] [(QPSK, 1@0 1@47, 3.75 kHz) measurements]
1. Execute ULSC_SPACE 3.75KHZ to set UL RMC Subcarrier Spacing to 3.75 kHz. 2. Execute ULRMC_SC 1 to set UL RMC - Number of Subcarrier to 1. 3. Execute ULSC_START 0 to set UL RMC – Starting Subcarrier to 0. 4. Execute ULIMCS 3 to set UL RMC – MCS Index to 3. 5. Execute NRSPWR 21 to set nrs-Power to 21. 6. Execute P0_NOMNPUSCH -115 to set p0-NominalNPUSCH to -115. 7. Execute ILVL 30.0 to set Input Level to +30 dBm. 8. Update Broadcast Information (2.5) 9. Wait about 200 ms until the UE power becomes the maximum output power.
26
10. Execute SWP to measure Modulation Analysis. 11. Execute EVM? AVG to read the EVM measurement result. 12. Confirm the measurement result is less than 17.5%. 13. Execute RSEVM? AVG to read the Reference Signal EVM measurement result. 14. Confirm the measurement result is less than 17.5%. 15. Execute ULSC_START 47 to set UL RMC – Starting Subcarrier to 47. 16. Update Broadcast Information (2.5) 17. Execute steps 9 to 14 at Test point2. [(QPSK, 1@0 1@11, 15 kHz) measurements] 18. Execute ULSC_SPACE 15KHZ to set UL RMC Subcarrier Spacing to 15 kHz. 19. Execute ULRMC_SC 1 to set UL RMC - Number of Subcarrier to 1. 20. Execute ULSC_START 0 to set UL RMC – Starting Subcarrier to 0. 21. Execute ULIMCS 3 to set UL RMC – MCS Index to 3. 22. Update Broadcast Information (2.5) 23. Execute steps 9 to 14 at Test point2. 24. Execute ULSC_START 11 to set UL RMC – Starting Subcarrier to 11. 25. Update Broadcast Information (2.5) 26. Execute steps 9 to 14 at Test point2. [(QPSK, 12@0, 15 kHz) measurements] NOTE1 27. Execute ULSC_SPACE 15KHZ to set UL RMC Subcarrier Spacing to 15 kHz. 28. Execute ULRMC_SC 12 to set UL RMC - Number of Subcarrier to 12. 29. Execute ULSC_START 0 to set UL RMC – Starting Subcarrier to 0. 30. Execute ULIMCS 5 to set UL RMC – MCS Index to 5. 31. Update Broadcast Information (2.5) 32. Execute steps 9 to 14 at Test point2.
NOTE 1: Applicable to UE supporting UL multi-tone transmissions.
Error Vector Magnitude (EVM) for category NB1 (NPRACH) (6.5.2.1F.1) 3.1.11.
1. Execute MEASITEM NPRACH to set Measurement Item to NPRACH. 2. Execute OLVL_EPRE -110 to set Output Level to -110 dBm/15 kHz. 3. Execute ILVL 30.0 to set Input Level to +30 dBm. 4. Execute DLIMCS1 -1 to set DL RMC – MCS Index to N/A. 5. Execute NPRACH 1 to set NPRACH preamble format to 1. 6. Turn on UE power. 7. Execute CALLSO to clear call processing status. 8. Execute CALLSTAT? to confirm the call processing status is 1 (= Idle). 9. Execute SWPANDPG to measure Modulation Analysis (NPRACH).
10. Execute EVM? AVG to read the EVM measurement result. 11. Confirm the measurement result is less than 17.5%.
27
Carrier leakage for category NB1 (6.5.2.2F) 3.1.12. This chapter describes a UL measurement example when (Modulation, Ntones, Subcarrier Spacing) is (QPSK, 1@0 1@47, 3.75 kHz) or (QPSK, 1@0 1@11, 15 kHz).
1. Execute MOD_MEAS ON to set Modulation analysis to ON. 2. Execute MOD_AVG 20 to set the average count of Modulation Analysis to 20 times. 3. Execute OLVL -74 to set Output Level to -74 dBm. 4. Execute DLIMCS1 -1 to set DL RMC – MCS Index to N/A.
[Test point 1] [(QPSK, 1@0 1@47, 3.75 kHz) measurements]
5. Execute ULSC_SPACE 3.75KHZ to set UL RMC Subcarrier Spacing to 3.75 kHz. 6. Execute ULRMC_SC 1 to set UL RMC - Number of Subcarrier to 1. 7. Execute ULSC_START 0 to set UL RMC – Starting Subcarrier to 0. 8. Execute ULIMCS 3 to set UL RMC – MCS Index to 3. 9. Update Broadcast Information (2.5)
10. Execute ILVL 30 to set Input Level to 30 dBm. 11. Execute SWP to measure Modulation Analysis. 12. Execute CARRLEAK? MAX to read the Carrier Leakage measurement result. 13. Confirm the measurement result is less than -24.2 dBc. 14. Execute ULSC_START 47 to set UL RMC – Starting Subcarrier to 47. 15. Update Broadcast Information (2.5) 16. Execute steps 11 to 13. [QPSK, 1@0 1@11, 15 kHz] 17. Execute ULSC_SPACE 15KHZ to set UL RMC Subcarrier Spacing to 15 kHz. 18. Execute steps 6 to 13. 19. Execute ULSC_START 11 to set UL RMC – Starting Subcarrier to 11. 20. Update Broadcast Information (2.5) 21. Execute steps 11 to 13.
[Test point 2] [(QPSK, 1@0 1@47, 3.75 kHz) measurements]
1. Execute ULSC_SPACE 3.75KHZ to set UL RMC Subcarrier Spacing to 3.75 kHz. 2. Execute ULRMC_SC 1 to set UL RMC - Number of Subcarrier to 1. 3. Execute ULSC_START 0 to set UL RMC – Starting Subcarrier to 0. 4. Execute ULIMCS 3 to set UL RMC – MCS Index to 3. 5. Execute NRSPWR 21 to set nrs-Power to 21. 6. Execute P0_NOMNPUSCH -105 to set p0-NominalNPUSCH to -105. 7. Update Broadcast Information (2.5) 8. Execute ILVL 3.2 to set Input Level to 3.2 dBm. 9. Wait about 200ms until the UE power becomes 3.2 dBm.
10. Execute SWP to measure Modulation Analysis. 11. Execute CARRLEAK? MAX to read the Carrier Leakage measurement result. 12. Confirm the measurement result is less than -19.2 dBc. 13. Execute ULSC_START 47 to set UL RMC – Starting Subcarrier to 47. 14. Update Broadcast Information (2.5) 15. Execute steps 9 to 12. [QPSK, 1@0 1@11, 15 kHz] 16. Execute ULSC_SPACE 15KHZ to set UL RMC Subcarrier Spacing to 15 kHz. 17. Execute steps 2 to 12. 18. Execute ULSC_START 11 to set UL RMC – Starting Subcarrier to 11. 19. Update Broadcast Information (2.5) 20. Execute steps 9 to 12.
28
In-band emissions for non allocated RB for category NB1 (6.5.2.3F) 3.1.13. This chapter describes a UL measurement example when (Modulation, Ntones, Subcarrier Spacing) is (QPSK, 1@0 1@47, 3.75 kHz) or (QPSK, 1@0 1@11, 15 kHz).
1. Execute MOD_MEAS ON to set Modulation analysis to ON. 2. Execute MOD_AVG 20 to set the average count of Modulation Analysis to 20 times. 3. Execute DLIMCS1 -1 to set DL RMC – MCS Index to N/A.
[Test point 1] [(QPSK, 1@0 1@47, 3.75 kHz) measurements]
4. Execute ULSC_SPACE 3.75KHZ to set UL RMC Subcarrier Spacing to 3.75 kHz. 5. Execute ULRMC_SC 1 to set UL RMC - Number of Subcarrier to 1. 6. Execute ULSC_START 0 to set UL RMC – Starting Subcarrier to 0. 7. Execute ULIMCS 3 to set UL RMC – MCS Index to 3. 8. Execute ILVL 30 to set Input Level to 30 dBm. 9. Execute OLVL -60 to set Output Level to -60 dBm.
10. Update Broadcast Information (2.5) 11. Wait about 200ms. 12. Execute SWP to measure Modulation Analysis. 13. Execute INBANDE_GEN? MAX to read the In-Band Emissions (General) measurement result. 14. Execute INBANDE_IMG? MAX to read the In-Band Emissions (IQ Image) measurement result. 15. Execute INBANDE_LEAK? MAX to read the In-Band Emissions (Carrier Leakage) measurement result. 16. Execute INBANDE_GENUL? to read the In-Band Emissions (General) limit value. 17. Confirm the In-Band Emissions (General) measurement result is less than the In-Band Emissions (General)
limit value. 18. Confirm the In-Band Emissions (IQ Image) measurement result is less than -24.2dB. 19. Confirm the In-Band Emissions (Carrier Leakage) measurement result is less than -24.2 dBc. 20. Execute ILVL -10 to set Input Level to -10 dBm. 21. Execute OLVL -30 to set Output Level to -30 dBm. 22. Wait about 200ms. 23. Execute steps 12 to 16. 24. Confirm the In-Band Emissions (General) measurement result is less than the In-Band Emissions (General)
limit value. 25. Confirm the In-Band Emissions (IQ Image) measurement result is less than -24.2dB. 26. Confirm the In-Band Emissions (Carrier Leakage) measurement result is less than -19.2 dBc. 27. Execute ILVL -10 to set Input Level to -10 dBm. 28. Execute OLVL -12 to set Output Level to -12 dBm. 29. Wait about 200ms until the UE power becomes -36.8 dBm. 30. Execute steps 12 to 16. 31. Confirm the In-Band Emissions (General) measurement result is less than the In-Band Emissions (General)
limit value. 32. Confirm the In-Band Emissions (IQ Image) measurement result is less than -24.2dB. 33. Confirm the In-Band Emissions (Carrier Leakage) measurement result is less than -9.2 dBc. 34. Execute ULSC_START 47 to set UL RMC – Starting Subcarrier to 47. 35. Execute steps 8 to 33. [(QPSK, 1@0 1@11, 15 kHz) measurements] 36. Execute ULSC_SPACE 15KHZ to set UL RMC Subcarrier Spacing to 15 kHz. 37. Execute steps 8 to 33. 38. Execute ULSC_START 11 to set UL RMC – Starting Subcarrier to 11. 39. Execute steps 8 to 33. [Test point 2]
1. Execute MOD_MEAS ON to set Modulation analysis to ON. 2. Execute MOD_AVG 20 to set the average count of Modulation Analysis to 20 times.
29
[(QPSK, 1@0 1@47, 3.75kHz) measurements]
3. Execute ULSC_SPACE 3.75KHZ to set UL RMC Subcarrier Spacing to 3.75 kHz. 4. Execute ULRMC_SC 1 to set UL RMC - Number of Subcarrier to 1. 5. Execute ULSC_START 0 to set UL RMC – Starting Subcarrier to 0. 6. Execute ULIMCS 3 to set UL RMC – MCS Index to 3. 7. Execute ILVL 30 to set Input Level to 30 dBm. 8. Execute OLVL -60 to set Output Level to -60 dBm. 9. Execute NRSPWR 21 to set nrs-Power to 21.
10. Execute P0_NOMNPUSCH -105 to set p0-NominalNPUSCH to -105. 11. Update Broadcast Information (2.5) 12. Wait about 200 ms. 13. Execute SWP to measure Modulation Analysis. 14. Execute INBANDE_GEN? MAX to read the In-Band Emissions (General) measurement result. 15. Execute INBANDE_IMG? MAX to read the In-Band Emissions (IQ Image) measurement result. 16. Execute INBANDE_LEAK? MAX to read the In-Band Emissions (Carrier Leakage) measurement result. 17. Execute INBANDE_GENUL? to read the In-Band Emissions (General) limit value. 18. Confirm the In-Band Emissions (General) measurement result is less than the In-Band Emissions (General)
limit value. 19. Confirm the In-Band Emissions (IQ Image) measurement result is less than -24.2 dB. 20. Confirm the In-Band Emissions (Carrier Leakage) measurement result is less than -24.2 dBc. 21. Execute ILVL -10 to set Input Level to -10 dBm. 22. Execute OLVL -30 to set Output Level to -30 dBm. 23. Wait about 200 ms. 24. Execute steps 13 to 17 at Test point 2. 25. Confirm the In-Band Emissions (General) measurement result is less than the In-Band Emissions (General)
limit value. 26. Confirm the In-Band Emissions (IQ Image) measurement result is less than -24.2 dB. 27. Confirm the In-Band Emissions (Carrier Leakage) measurement result is less than -19.2 dBc. 28. Execute ILVL -10 to set Input Level to -10 dBm. 29. Execute OLVL -12 to set Output Level to -12 dBm. 30. Wait about 200 ms until the UE power becomes -36.8 dBm. 31. Execute steps 13 to 17 at Test point 2. 32. Confirm the In-Band Emissions (General) measurement result is less than the In-Band Emissions (General)
limit value. 33. Confirm the In-Band Emissions (IQ Image) measurement result is less than -24.2 dB. 34. Confirm the In-Band Emissions (Carrier Leakage) measurement result is less than -9.2 dBc. 35. Execute ULSC_START 47 to set UL RMC – Starting Subcarrier to 47. 36. Execute steps 7 to 34 at Test point 2. [(QPSK, 1@0 1@11, 15 kHz) measurements] 37. Execute ULSC_SPACE 15KHZ to set UL RMC Subcarrier Spacing to 15 kHz. 38. Execute steps 7 to 34 at Test point 2. 39. Execute ULSC_START 11 to set UL RMC – Starting Subcarrier to 11. 40. Execute steps 7 to 34 at Test point 2.
30
Occupied bandwidth for category NB1 (6.6.1F) 3.1.14. This chapter describes a UL measurement example when (Modulation, Ntones, Subcarrier Spacing) is (QPSK, 1@0, 3.75 kHz), (QPSK, 1@0, 15 kHz) or (QPSK, 12@0, 15 kHz).
1. Execute OBW_MEAS ON to set Occupied Bandwidth measurement to ON. 2. Execute OBW_AVG 20 to set the average count of Occupied Bandwidth to 20 times. 3. Execute ILVL 30.0 to set Input Level to +30 dBm. 4. Execute OLVL -74 to set Output Level to -74 dBm. 5. Execute DLIMCS1 -1 to set DL RMC – MCS Index to N/A.
[(QPSK, 1@0, 3.75 kHz) measurements]
6. Execute ULSC_SPACE 3.75KHZ to set UL RMC Subcarrier Spacing to 3.75 kHz. 7. Execute ULRMC_SC 1 to set UL RMC - Number of Subcarrier to 1. 8. Execute ULIMCS 3 to set UL RMC – MCS Index to 3. 9. Update Broadcast Information (2.5)
10. Execute SWP to measure the Occupied Bandwidth. 11. Execute OBW? to read the OBW measurement result. 12. Confirm the measurement result is less than 200 kHz. [(QPSK, 1@0, 15 kHz) measurements] 13. Execute ULSC_SPACE 15KHZ to set UL RMC Subcarrier Spacing to 15 kHz. 14. Update Broadcast Information (2.5) 15. Execute steps 10 to 12. [(QPSK, 12@0, 15 kHz) measurements] NOTE 1 16. Execute ULRMC_SC 12 to set UL RMC - Number of Subcarrier to 12. 17. Execute ULIMCS 5 to set UL RMC – MCS Index to 5. 18. Update Broadcast Information (2.5) 19. Execute steps 10 to 12.
NOTE 1: Applicable to UE supporting UL multi-tone transmissions.
Figure 3.1.13-1 Example of Measurement Result
31
Spectrum Emission Mask for category NB1 (6.6.2.1F) 3.1.15. This chapter describes UL measurement examples when (Modulation, Ntones, Subcarrier Spacing) is (QPSK, 1@0 1@47, 3.75 kHz), (QPSK, 1@0 1@11, 15 kHz), (QPSK, 3@0 3@3 3@9, 15 kHz), (QPSK, 6@0 6@6, 15kHz) or (QPSK, 12@0, 15 kHz).
1. Execute SEM_MEAS ON to set Spectrum Emission Mask measurement to ON. 2. Execute SEM_AVG 20 to set the average count of Spectrum Emission Mask to 20 times. 3. Execute ILVL 30.0 to set Input Level to +30 dBm. 4. Execute OLVL -74 to set Output Level to -74 dBm. 5. Execute DLIMCS1 -1 to set DL RMC – MCS Index to N/A.
[(QPSK, 1@0 1@47, 3.75 kHz) measurements]
6. Execute ULSC_SPACE 3.75KHZ to set UL RMC Subcarrier Spacing to 3.75 kHz. 7. Execute ULRMC_SC 1 to set UL RMC - Number of Subcarrier to 1. 8. Execute ULSC_START 0 to set UL RMC – Starting Subcarrier to 0. 9. Execute ULIMCS 3 to set UL RMC – MCS Index to 3.
10. Update Broadcast Information (2.5) 11. Execute SWP to measure the Spectrum Emission Mask. 12. Execute SEMPASS? to check that the SEM Pass/Fail judgement is Pass. 13. Execute ULSC_START 47 to set UL RMC – Starting Subcarrier to 47. 14. Update Broadcast Information (2.5) 15. Execute steps 11 to 12. [(QPSK, 1@0 1@11, 15 kHz) measurements] 16. Execute ULSC_SPACE 15KHZ to set UL RMC Subcarrier Spacing to 15 kHz. 17. Execute ULRMC_SC 1 to set UL RMC - Number of Subcarrier to 1. 18. Execute ULSC_START 0 to set UL RMC – Starting Subcarrier to 0. 19. Execute ULIMCS 3 to set UL RMC – MCS Index to 3. 20. Update Broadcast Information (2.5) 21. Execute steps 11 to 12. 22. Execute ULSC_START 11 to set UL RMC – Starting Subcarrier to 11. 23. Update Broadcast Information (2.5) 24. Execute steps 11 to 12. [(QPSK, 3@0 3@3 3@9, 15 kHz) measurements] NOTE 1 25. Execute ULRMC_SC 3 to set UL RMC - Number of Subcarrier to 3. 26. Execute ULSC_START 0 to set UL RMC – Starting Subcarrier to 0. 27. Execute ULIMCS 5 to set UL RMC – MCS Index to 5. 28. Update Broadcast Information (2.5) 29. Execute steps 11 to 12. 30. Execute ULSC_START 3 to set UL RMC – Starting Subcarrier to 3. 31. Update Broadcast Information (2.5) 32. Execute steps 11 to 12. 33. Execute ULSC_START 9 to set UL RMC – Starting Subcarrier to 9. 34. Update Broadcast Information (2.5) 35. Execute steps 11 to 12. [(QPSK, 6@0 6@6, 15 kHz) measurements] NOTE 1 36. Execute ULRMC_SC 6 to set UL RMC - Number of Subcarrier to 6. 37. Execute ULSC_START 0 to set UL RMC – Starting Subcarrier to 0. 38. Execute ULIMCS 5 to set UL RMC – MCS Index to 5. 39. Update Broadcast Information (2.5) 40. Execute steps 11 to 12. 41. Execute ULSC_START 6 to set UL RMC – Starting Subcarrier to 6. 42. Update Broadcast Information (2.5) 43. Execute steps 11 to 12. [(QPSK, 12@0 15 kHz) measurements] NOTE 1
32
44. Execute ULRMC_SC 6 to set UL RMC - Number of Subcarrier to 6. 45. Execute ULSC_START 0 to set UL RMC – Starting Subcarrier to 0. 46. Execute ULIMCS 5 to set UL RMC – MCS Index to 5. 47. Update Broadcast Information (2.5) 48. Execute steps 11 to 12.
NOTE 1: The allowed MPR for the UE applied maximum output power is described in clause [6.2.3F.3] in TS 36.521-1.
Figure 3.1.14-1 Example of Measurement Result
33
Adjacent Channel Leakage power Ratio for category NB1 (6.6.2.3F) 3.1.16. This chapter describes UL measurement examples when (Modulation, Ntones, Subcarrier Spacing) is (QPSK, 1@0 1@47, 3.75 kHz), (QPSK, 1@0 1@11, 15 kHz), (QPSK, 3@0 3@3 3@9, 15 kHz), (QPSK, 6@0 6@6, 15kHz) or (QPSK, 12@0, 15 kHz).
1. Execute ACLR_MEAS ON to set Adjacent channel leakage power measurement to ON. 2. Execute ACLR_AVG 20 to set the average count of ACLR to 20 times. 3. Execute ILVL 30.0 to set Input Level to +30 dBm. 4. Execute OLVL -74 to set Output Level to -74 dBm. 5. Execute DLIMCS1 -1 to set DL RMC – MCS Index to N/A.
[(QPSK, 1@0 1@47, 3.75 kHz) measurements]
6. Execute ULSC_SPACE 3.75KHZ to set UL RMC Subcarrier Spacing to 3.75 kHz. 7. Execute ULRMC_SC 1 to set UL RMC - Number of Subcarrier to 1. 8. Execute ULSC_START 0 to set UL RMC – Starting Subcarrier to 0. 9. Execute ULIMCS 3 to set UL RMC – MCS Index to 3.
10. Update Broadcast Information (2.5) 11. Execute SWP to measure the Adjacent Channel Power. 12. Execute MODPWR? G_LOW1,AVG to read the GSM -5 MHz ACLR measurement result. 13. Execute MODPWR? G_UP1,AVG to read the GSM +5 MHz ACLR measurement result. 14. Execute MODPWR? LOW1,AVG to read the UTRA -5 MHz ACLR measurement result. 15. Execute MODPWR? UP1,AVG to read the UTRA +5 MHz ACLR measurement result. 16. Confirm the GSM -5 MHz ACLR measurement result is less than 19.2 dB. 17. Confirm the GSM +5 MHz ACLR measurement result is less than 19.2 dB. 18. Confirm the UTRA -5 MHz ACLR measurement result is less than 36.2 dB. 19. Confirm the UTRA +5 MHz ACLR measurement result is less than 36.2 dB. 20. Execute ULSC_START 47 to set UL RMC – Starting Subcarrier to 47. 21. Update Broadcast Information (2.5) 22. Execute steps 11 to 19. [(QPSK, 1@0 1@11, 15 kHz) measurements] 23. Execute ULSC_SPACE 15KHZ to set UL RMC Subcarrier Spacing to 15 kHz. 24. Execute ULRMC_SC 1 to set UL RMC - Number of Subcarrier to 1. 25. Execute ULSC_START 0 to set UL RMC – Starting Subcarrier to 0. 26. Execute ULIMCS 3 to set UL RMC – MCS Index to 3. 27. Update Broadcast Information (2.5) 28. Execute steps 11 to 19. 29. Execute ULSC_START 11 to set UL RMC – Starting Subcarrier to 11. 30. Update Broadcast Information (2.5) 31. Execute steps 11 to 19. [(QPSK, 3@0 3@3 3@9, 15 kHz) measurements] NOTE 1 32. Execute ULRMC_SC 3 to set UL RMC - Number of Subcarrier to 3. 33. Execute ULSC_START 0 to set UL RMC – Starting Subcarrier to 0. 34. Execute ULIMCS 5 to set UL RMC – MCS Index to 5. 35. Update Broadcast Information (2.5) 36. Execute steps 11 to 19. 37. Execute ULSC_START 3 to set UL RMC – Starting Subcarrier to 3. 38. Update Broadcast Information (2.5) 39. Execute steps 11 to 19. 40. Execute ULSC_START 9 to set UL RMC – Starting Subcarrier to 9. 41. Update Broadcast Information (2.5) 42. Execute steps 11 to 19. [(QPSK, 6@0 6@6, 15 kHz) measurements] NOTE 1 43. Execute ULRMC_SC 6 to set UL RMC - Number of SC to 6. 44. Execute ULSC_START 0 to set UL RMC – Starting Subcarrier to 0.
34
45. Execute ULIMCS 5 to set UL RMC – MCS Index to 5. 46. Update Broadcast Information (2.5) 47. Execute steps 11 to 19. 48. Execute ULSC_START 6 to set UL RMC – Starting Subcarrier to 6. 49. Update Broadcast Information (2.5) 50. Execute steps 11 to 19. [(QPSK, 12@0, 15 kHz) measurements] NOTE 1 51. Execute ULRMC_SC 12 to set UL RMC - Number of SC to 12. 52. Execute ULSC_START 0 to set UL RMC – Starting Subcarrier to 0. 53. Execute ULIMCS 5 to set UL RMC – MCS Index to 5. 54. Update Broadcast Information (2.5) 55. Execute steps 11 to 19.
NOTE 1: Applicable to UE supporting UL multi-tone transmissions.
Figure 3.1.15-1 Example of Measurement Result
35
RX Measurements 3.1.17.The following test procedure can be used for the MT8821C.
Reference sensitivity level for UE category NB1 (7.3F.1) 3.2.1.
1. Execute ALLMEASITEMS_OFF to set all fundamental measurement items to OFF. 2. Execute TPUT_MEAS ON to set Throughput measurement to ON. 3. Execute TPUT_SAMPLE 10000 to set Rx Measurement Parameter - Throughput - Number of Samples to 10000. 4. Execute ULSC_SPACE 15KHZ to set UL RMC – Subcarrier Spacing to 15 kHz. 5. Execute ULRMC_SC 1 to set UL RMC – Number of Subcarrier to 1. 6. Execute ULSC_START 0 to set UL RMC – Starting Subcarrier to 0. 7. Execute ULIMCS 0 to set UL RMC – MCS Index to 0. 8. Execute ULRMC_RU 2 to set UL RMC – Number of Resource Units to 2. 9. Execute ILVL 30.0 to set Input Level to +30 dBm.
10. Execute OLVL -107.5 to set Output level to -107.5 dBm. 11. Update Broadcast Information (2.5) 12. Execute SWP to measure the Throughput. 13. Execute TPUT? PER to read the Throughput measurement result (%). 14. Confirm the Throughput measurement result is more than 95%.
Figure 3.2.1-1 Example of Measurement Result
36
Maximum input level for UE category NB1 (7.4F) 3.2.2.
1. Execute ALLMEASITEMS_OFF to set all fundamental measurement items to OFF. 2. Execute TPUT_MEAS ON to set Throughput measurement to ON. 3. Execute TPUT_SAMPLE 10000 to set Rx Measurement Parameter - Throughput - Number of Samples to 10000. 4. Execute ULSC_SPACE 15KHZ to set UL RMC – Subcarrier Spacing to 15 kHz. 5. Execute ULRMC_SC 1 to set UL RMC – Number of Subcarrier to 1. 6. Execute ULSC_START 0 to set UL RMC – Starting Subcarrier to 0. 7. Execute ULIMCS 0 to set UL RMC – MCS Index to 0. 8. Execute ULRMC_RU 2 to set UL RMC – Number of Resource Units to 2. 9. Execute ILVL 17.3 to set Input Level to +17.3 dBm.
10. Execute OLVL -25.7 to set Output level to -25.7 dBm. 11. Update Broadcast Information (2.5) 12. Execute SWP to measure the Throughput. 13. Execute TPUT? PER to read the Throughput measurement result (%). 14. Confirm the Throughput measurement result is more than 95%.
NOTE 1: When the Carrier Frequency exceeds 3 GHz, the required test Rx power value is not defined in TS36.521(2017-03).
Figure 3.2.2-1 Example of Measurement Result
37
IP Data Transfer Test 4.
IP Data Transfer Test for Category NB1 4.1. The IP data transfer between an application server connected to the MT8821C and the UE can be tested by installing the 17C-006 IP Data Transfer option in the MT8821C. The following test procedure is based on hands-on operation. Refer to the LTE measurement software operation manual for the basic operation and remote commands.
4.1.1.2. Connection Diagram for IP Data Verification using MT8821C
Figure 4.1.1-2 Connection Diagram for IP Data Transfer (MT8821C, using internal server)
<Required Equipment> Category NB1 mobile terminal supporting IP connection
RF cable to connect MT8821C and Category NB1mobile terminal
Client PC (if DUT is modem type or using tethering function) Crossover cable to connect MT8821C and application server
38
UDP/TCP Throughput measurement software (installed in application server and client PCs)*1
*1: This test uses the open-source software Iperf to measure throughput. It can be downloaded from the Internet. After downloading, copy the execute file (Iperf.exe) to the root of the C: drives in the application server and client PCs.
* Windows is registered trademark of Microsoft Corporation in the USA and other countries. NOTES: There is no need to connect the server PC and MT8821C with a router when testing IP data transfer
using IPv6. Connect the server PC and MT8821C as shown above. The IPv6 address is assigned automatically to the UE in use. A UE not supporting automatic IPv6
address assignment uses the IP address set at IPv6Client IP Address of the MT8821C. Check that the UE supports IPv6 before testing IP data transfer using IPv6. Connect the UE and
MT8821C to check the PDN Type on the UE Report screen. The UE supports IPv6 when either IPv4v6 or IPv6 is displayed in PDN Type on the UE Report screen.
Figure 4.1.1-2 UE Report Screen (MT8821C)
39
Application Server Connection and Setting 4.1.2. With the MT8821C powered-down (OFF), use a crossover Ethernet cable to connect the 1000Base-TX/100Base-TX/10Base-T port on the back panel of the MT8821C to the application server. Set TCP/IP of the internal Application Server. 4.1.2.1. IPv4 Setting TCP/IP of Application Server.
1. Open the Control Panel – Network and Sharing Center – Change adapter setting, and double–click the Application Server1(Phone1). *Application Server2 is for Phone2.
2. Open the Local Area Connection Properties window at the Application Serve1 and put a checkmark in the Internet Protocol (TCP/IP) checkbox.
Figure 4.1.2.1-2 Local Area Network Connection Properties
40
3. Double-click Internet Protocol (TCP/IP) to open the Internet Protocol (TCP/IP) Properties window.
Figure 4.1.2.1-3 Internet Protocol (TCP/IP) Properties Window
4. Choose [Use the following IP address] and set [IP address] and [Subnet mask] as follows:
IP address: 192.168.20.10 Subnet mask: 255.255.255.0 NOTE: For Phone1 and/or Phone2, set the same Application Server IP addresses in Call Processing→
Packet→[Server IP Address] parameter. Set Phone1 [Server IP Address] to Application Server1 IP address and set Phone2 [Server IP Address] to Application Server2 IP address.
Figure 4.1.2.1–4 Server IPv4 Address Setting Screen (MT8821C)
5. Click [OK] to close the Internet Protocol (TCP/IP) Properties window.
41
6. Select the [Advanced] tab at the Local Area Connection Properties window and disable the Windows firewall.
Figure 4.1.2.1-5 Advanced Tab of Local Area Network Connection Properties Window
7. Click [OK] to close the window. 8. Start the MT8821C. 9. Select and load the NB-IoT measurement software to Phone1.
10. After loading, start the NB-IoT measurement software on Phone1.
42
4.1.2.2. IPv6 Set TCP/IP of Application Server.
NOTE: The TCP/IP version 6 installation procedure is not required. Disable the Windows firewall.
1. Open the Control Panel – Network and Sharing Center – Change adapter setting, and double-click the
Application Server1(Phone1). *Application Server2 is for Phone2.
Figure 4.1.2.2-1 Change Adapter Setting Window (MT8821C) 2. Double-click [Internet Protocol Version 6 (TCP/IPv6)] to open the Internet Protocol Version 6 (TCP/IPv6)
properties screen.
Figure 4.1.2.2-2 Local Area Connection Properties Screen (MT8821C)
43
Figure 4.1.2.2-3 Internet Protocol Version 6 (TCP/IPv6) Properties Screen (MT8821C)
3. Select [Use following IPv6 address] and set [IPv6 address] and [Subnet prefix length] as described below. The IPv6 address set by this procedure matches the IP address set at [IPV6 Server IP Address ] of the MT8821C. To check [IPV6 Server IP Address ] of the MT8821C, refer to Figure 4.1.2.2.2-4. IPv6 address: 2001::2 Subnet prefix length: 64
NOTE: Places in the address with contiguous 0s are abbreviated as::. For example, IPv6 Server IP Address
2001:0000:0000:0000:0000:0000:0000:0002 is abbreviated to 2001::2. For Phone1 and/or Phone2, set the same IPv6 addresses in Call Processing→Packet→[IPv6 Server IP
Address] parameter. Set Phone1 [IPv6 Server IP Address] to Application Server1 IPv6 address and set Phone2 [IPv6 Server IP Address] to Application Server2 IPv6 address.
Figure 4.1.2.2.2-4 Server IPv6 Address Setting Screen (MT8821C)
4. Click [OK] and close the properties screen for Internet Protocol Version 6 (TCP/IPv6).
44
Client PC Connection and Setting 4.1.3. The client PC connection and setting depend on the mobile terminal. Set according to the connection method used.
Initial Condition Setting 4.1.4. The following illustrates how to set-up the measurement condition for Peak Data Rate. TS36.306 4.1c defines a transmittable data size for the respective UE Categories. 4.1.4.1. IPv4
1. Execute [Preset] to Initialize. 2. Set [Channel Coding] to Packet.
Figure 4.1.4.1-1 Channel Coding Setting at Common Parameter Screen (MT8821C)
3. Set [Client IPv4 Address] to 192.168.10.11.
Figure 4.1.4.1-2 lient IP Address Setting at Call Processing Parameter Screen (MT8821C)
45
4. Set [Throughput] at the Fundamental Measurement Parameter screen to On.
Figure 4.1.4.1-3 Throughput Measurement Setting at Fundamental Measurement Parameter Screen
(MT8821C) 4.1.4.2. IPv6 This measurement can be performed using the same procedure as in Chapter 4.1.4.1, by substituting the following steps.
1. Set [IPv6 Server IP Address] to 2001::2. 2. Set [IPv6 Client IP Address] to 2001::1.
Location Registration and Packet Connection 4.1.5.4.1.5.1. IPv4 Perform UE location registration and packet connection.
1. Connect the UE to the MT8821C. 2. Switch on the UE. 3. Wait for packet communication from the mobile terminal to be established.
The MT8821C Call Processing status changes from IdleRegistrationConnected. 4. Press Single to set Input level near to the Tx power measurement result.
Run the Ping command from the Command Prompt window of the client or application server to confirm the IP connection. The following figure shows the result for the application server.
Figure 4.1.5.1-1 Ping Result at Application Server
5. Change UL RMC and DL RMC of the Common Parameter Setting screen to change the Transport Block Size
(TBS).
Figure 4.1.5.1-2 UL/DL RMC Settings at Common Parameter Setting Screen (MT8821C)
47
6. Press [Single] to confirm that the MT8821C downlink signal can be decoded at the UE by using the DL
Throughput and the Block Error Rate results of the Fundamental Measurement screen. If there is an error, change the RMC settings or Level setting, and repeat steps 5 and 6.
Figure 4.1.5.1-3 Throughput Measurement Result at Fundamental Measurement Parameter Screen
(MT8821C)
48
4.1.5.2. IPv6 This measurement can be performed using the same settings as in Chapter 4.1.5.1, by substituting the following steps.
4. Open Command Prompt at the client PC and run the “ipconfig” command. As shown at the following
Command Prompt screen, the IPv6 address of the UE starts with the prefix 2001 and has a different
Interface ID from the Local Link address. NOTES: Interface ID specifies the least-significant 64 bits of the IPv6 address. The IP address starting with 2001::xxxx:xxxx:xxxx:xxxx at the Command Prompt screen shown below, is
called the global address. On the other hand, the IP address starting with fe80::xxxx:xxxx:xxxx:xxxx is called the local link address.
A UE not supporting automatic IPv6 address assignment uses the IP address set at IPv6Client IP Address of the MT8821C.
Figure 4.1.5.2-1 Client PC IP Configuration
5. Run the Ping command at the Command Prompt screen of the server PC to confirm the connection status.
Figure 4.1.5.2-2 Result of Pinging to Client PC from Server PC
49
TCP/UDP Throughput 4.1.6.*This is not supported yet. It will be supported in future.
50
IP Data Application 4.2.
This chapter describes ping execution and TCP/UDP throughput verification using Iperf in the MT8821C NB-IoT measurement software.
ping 4.2.1. The following procedure describes the ping execution sequence for an IPv4 Packet-connected UE. The ping command is as follows.
ping 192.168.20.11 -w 40000 -l 32 -S 192.168.20.10 1. Perform IPv4 connection procedure in chapter 4.1.5 and 4.1.6 to establish UE Packet connection. 2. Execute PINGDSTIP S1,192,168,20,11 to set PING - Destination IPv4 Address of server 1 to 192.168.20.11. 3. Execute PINGIP S1,IPV4 to set PING - IP Type of server 1 to IPv4. 4. Execute PINGW S1,40000 to set PING - Interval of server 1 to 40000. 5. Execute PINGL S1,32 to set PING - Buffer Size of server 1 to 32 byte. 6. Execute RSLTAREA IPDATATAB to open IP Data tab. 7. Execute PINGSINGLS S1 to execute ping. 8. Confirm the result of the ping on the screen.
NOTE: Use Application Server1,2 IP address described in chapter 4.1.2 as the server address where the
ping is sent. The server address is specified by the “-s” option in the ping command.
Iperf 4.2.2.*This is not supported yet. It will be supported in future.
51
Anritsu Company 1155 East Collins Blvd., Suite 100, Richardson, TX 75081, U.S.A.Toll Free: 1-800-267-4878Phone: +1-972-644-1777Fax: +1-972-671-1877
• RussiaAnritsu EMEA Ltd. Representation Office in RussiaTverskaya str. 16/2, bld. 1, 7th floor.Moscow, 125009, RussiaPhone: +7-495-363-1694Fax: +7-495-935-8962
• SpainAnritsu EMEA Ltd.Representation Office in SpainEdificio Cuzco IV, Po. de la Castellana, 141, Pta. 528046, Madrid, SpainPhone: +34-915-726-761Fax: +34-915-726-621
• United Arab EmiratesAnritsu EMEA Ltd. Dubai Liaison Office
• P.R. China (Shanghai)Anritsu (China) Co., Ltd.Room 2701-2705, Tower A, New Caohejing International Business CenterNo. 391 Gui Ping Road Shanghai, 200233, P.R. ChinaPhone: +86-21-6237-0898Fax: +86-21-6237-0899
• P.R. China (Hong Kong)Anritsu Company Ltd.Unit 1006-7, 10/F., Greenfield Tower, Concordia Plaza,No. 1 Science Museum Road, Tsim Sha Tsui East, Kowloon, Hong Kong, P.R. ChinaPhone: +852-2301-4980Fax: +852-2301-3545
• JapanAnritsu Corporation
Phone: +81-46-296-6509Fax: +81-46-225-8352
8-5, Tamura-cho, Atsugi-shi, Kanagawa, 243-0016 Japan