SURE HEAT Installation and Operating Instructions for NATURAL & L.P. GAS VENTED GAS LOG SETS Model: VMO24NG/VM024LP Sure Heat Manufacturing 1861 West Oak Parkway Marietta, GA 30062 Tel: 800-229-5647 Fax: 770-424-3842 WARNING: It is very important to read the instructions in this manual before starting installation. - Do not attempt to modify or alter the construction of the fireplace or its components. Any modification or alteration may void the warranty of these units. WARNING: Solid fuel shall not be burned in a fireplace where a decorative appliance is installed. WARNING: If the information in this manual is not followed exactly, a fire or explosion may result causing property damage, personal injury or loss of life. - Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance. - WHAT TO DO IF YOU SMELL GAS: • Do not try to light any appliance. • Do not touch any electrical switch; do not use any phone in your building. • Immediately call your gas supplier from a neighbor’s telephone. Follow the gas supplier’s instructions. • If you cannot reach your gas supplier, call the fire department. - Installation and service must be performed by a qualified installer, service agency or the gas supplier. Batteries not included. Batteries required: 3 “AAA’s” for remote and 4 “AA’s” for remote receiver.
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
SURE HEATInstallation and Operating Instructions for
NATURAL & L.P. GASVENTED GAS LOG SETS
Model: VMO24NG/VM024LP
Sure Heat Manufacturing1861 West Oak Parkway
Marietta, GA 30062Tel: 800-229-5647Fax: 770-424-3842
WARNING: It is very important to read the instructions in this manual before starting installation. - Donotattempttomodifyoraltertheconstructionofthefireplaceoritscomponents. Anymodificationoralterationmayvoidthewarrantyoftheseunits. WARNING:Solidfuelshallnotbeburnedinafireplacewhereadecorativeapplianceisinstalled.
- WHAT TO DO IF YOU SMELL GAS: • Donottrytolightanyappliance. • Donottouchanyelectricalswitch;donotuseanyphoneinyourbuilding. • Immediatelycallyourgassupplierfromaneighbor’stelephone.Followthegassupplier’sinstructions. • Ifyoucannotreachyourgassupplier,callthefiredepartment.
IMPORTANT INFORMATION- Duetohightemperatures,theapplianceshouldbelocatedoutoftrafficandawayfromfurnitureanddraperies.- Donotplaceclothingorotherflammablematerialonorneartheappliance.- Childrenandadultsshouldbealertedtothehazardsofhighsurfacetemperatureandshouldstayawaytoavoid burns or clothing ignition.- Youngchildrenshouldbecarefullysupervisedwhentheyareinthesameroomwiththeappliance.- Please retain this manual for future reference.- Theinstallationmustconformwithlocalcodes,orintheabsenceoflocalcodes,withtheNationalFuelGasCode ANSI Z223.1/NFPA 54, or the CSA B149.1, Natural Gas and Propane Installation Code.- Thisappliancemustbeinstalledonlyinasolidfuelfireplacewithaworkingflueandconstructedof non-combustible material.- Installationandrepairshouldbedonebyaqualifiedservicetechnician.- Theapplianceshouldbeinspectedbeforeuseandatleastannuallybyaqualifiedservicetechnician.Morefrequent cleaningmaybenecessaryduetoexcessivedustorcarpetlint.Itisimportantthatthecirculatingairpassageways bekeptclean.- Keepapplianceclearandfreefromcombustiblematerials,gasolineandotherflammablevaporsandliquids.
FIREPLACE SIZING GUIDE:
Opening Front Rear Fireplace Chimney Set Size Height Width Width Depth Opening 24” 18” 28” 20” 15” 50sq.in.
Itisnecessarytoprovideadequatecombustionandventilationair.Airforcombustionandventilationmustnotbeobstruct-ed.Provideadequateclearancearoundairopeninginthecombustionchamberandadequateaccessibilityclearanceforservicing and proper operation.
NEVER obstruct the front opening of the fireplace.
WARNING: Any safety guard remove for servicing and appliance must be replaced before operating the appliance.
Gas Piping and Gas Pressure RequirementsPREPARATION• Checkthetypeofgasthatissuppliedtoyourfireplace.Onlyinstalltheunitthatisequippedtooperateonthegas thatissuppliedtoyourfireplace.• Allgaspipingmustbeinstalledtocomplywithlocalandnationalfuelgascodes.• CompoundsusedonthreadedjointsofgaspipingmustberesistanttotheactionofL.P.gas.• Beforeinstallingtheunit,itisnecessarytoclosethemaingasvalveatthegasmeterorL.P.tank.Ensurethatthere isproperventilationintheareainwhichsystemisoperating.
Page 3
IMPORTANT INFORMATIONTheminimuminletgassupplypressureis5.5incheswatercolumnfornaturalgasand11.0incheswatercolumnforpropane.Themaximumallowableinletgassupplypressureis10.5incheswatercolumnfornaturalgasand13.0incheswatercolumnforpropane.If this appliance is to be supplied withL.P.gasthetankorbottlesupplyingthegasmusthavearegulatorthatreducesgaspressurebetween11and13incheswatercolumn.
WARNING: Thisappliancemustbeisolatedfromthegassupplypipingsystembyclosingits individual manual shutoff valve during any pressure testing of the gas supply piping systemattestpressuresequaltoorlessthan1/2PSIG.
Set Natural Gas L.P. Gas 24” 60,000BTUs 60,000BTUs
INSTALLATION TO EXISTING GAS LINE IN FIREPLACEAmanualON/OFFvalveshouldbepresentwithineasyreachoftheGaslogset.Ifamanualvalveisnotpresent,onemustbeinstalledpriortothegasloginstallation.
INSTALLATION IN A MASONRY FIREPLACEA1/2”gassupplylinemustbeprovidedtothefireplace.MostinstallationsrequiredrillinganaccessholethroughtheMasonrywall.Thesupplylineshouldbesecuredandsealedbymortarwithintheaccesshole.ThesupplylineshouldalsohaveanON/OFFvalveinthewallorinsidethefireplace.
BURNER SYSTEM LOCATION1. TheBurnerSystemshouldbelocatedtowardsthebackandcenteredinthecombustionchamber oftheventedfireplace.TheBurnerSystemshouldbecenteredfromlefttoright,withaboutan inch of space on either side.
CONNECTING GAS SUPPLY TO BURNER PAN AND LOG GRATE PLACEMENT1. Place Burner System in proper location.
A. Spread granules over the installed burner pan. Granulesshouldnotfilluptheentirepan.The granules should stop 3/4” - 1” from the top of the pan.SlopetheGranulesdowntowardthefront ofthepanwithoutoverflowingthemoverthe frontlipoftheburnerpan.(See Figure 3)
B. Spreadglowingembersoverthetopofthe granules,coveringtheentiresurfacearea, concentrating on the front and sides of the burner pan for the most realistic burning effect. (See Figure 3)
IMPORTANT INFORMATION
Gas SupplyStub
Gas Inlet Fitting
Flared Tubing
Figure 2
Figure 3
GlowingEmbers Granules
Page 5
IMPORTANT INFORMATIONLOG PLACEMENT
Place burner system in middle of fireplace.
Place Back Main Log on back of Burner Frame
Arrange Three (3) Top Logs over the Main Logs.
Place Front Main Log in front of burner system.
Place Middle Main Log in position. Make sure the log notch is placed
over the burner.
Arrange Two (2) Cover Logs in front of Control Valve and Remote Sensor.
IMPORTANT INFORMATIONFOR YOUR SAFETY READ BEFORE LIGHTING
WARNING: If you do not follow these instructions exactly, a fire or explosion may resultcausing property damage, personal injury or loss of life.
A. Thisapplianceisequippedwithanignitiondevice(piezo)whichlightsthepilotautomatically.If thepiezofailtolightthepilot,turnto“Match Lighting”InstructionsonPage9.
B. BEFORELIGHTINGtheunit,smellaroundtheapplianceareaforgas.Besuretosmellnextto thefloorbecausesomegasisheavierthanairandwillsettleonthefloor.
WHAT TO DO IF YOU SMELL GAS:
• Do not try to light any appliance. • Do not touch any electrical switch. • Do not use any telephone in your building. • Immediately call your gas supplier from a neighbor’s telephone. • Follow the gas supplier’s instructions. • If you cannot reach your gas supplier, call the fire department. • Installation and service must be performed by a qualified installer, service agency or the gas supplier.
C. Use only your hand to push in or turn the Pilot Control Knob.Neverusetools.Iftheknobwillnot pushinorturnbyhand,donottrytorepair,callaqualifiedservicetechnician.
WARNING: THE USE OF FORCE OR ATTEMPTED REPAIR MAY RESULT IN A FIRE OR EXPLOSION
D. Donotusethisapplianceifanyparthasbeenunderwater.Immediatelycallaqualifiedservice technician to inspect the appliance and replace any part of the control system and any gas controlwhichhasbeenunderwater.
PIEZO
Page 7
REMOTE CONTROL INFORMATION
TECHNICAL DATAREMOTE CONTROL:
Supply voltage:4.5V(three1.5V“AAA”batteries)Ambient Temperature Ratings:
0-60ºC(32-140ºF)Radio frequency:
315MHz
RECEIVER:Supply voltage:
6.0V(four1.5V“AA”batteries)Ambient temperature ratings:
0-60°C(32-140°F)Radio frequency:
315MHz
THIS DEVICE COMPLIES WITH PART 15 OF THE FCC RULES. OPERATION IS SUBJECT TO THE FOLLOWING TWO CONDITIONS:
1). Thisdevicemaynotcauseharmfulinterference,AND2). Thisdevicemustacceptanyinterferencereceived,including interference that may cause undesired operation.
ATTENTION:- Turn“OFF”maingassupplyoftheapplianceduringinstallationor maintenance of the receiver. - Placethereceiver’s3positionsliderswitchinthe“OFF”position during installation or maintenance.- Turn“OFF”maingassupplyoftheappliancepriortoremovingor reinserting the batteries in the receiver.
COMMUNICATION BETWEEN THE REMOTE CONTROL
AND THE RECEIVER
Toprogramthetransmittertothereceiver,move the three positions slider of the receiver intheREMOTEpositionanddepresstheON/OFFkeyofthetransmitter.TheSystem
Install three (3) “AAA” batteries into the remote control as
shown on the left.
LIGHTING INSTRUCTIONS1. STOP!Readthesafetyinformationlabelfoundontheunit.2. Makesuretheswitch(NotthePilot Control Knob)isturnedto“OFF”(See Figure 4)3. Turnoffallelectricalpowertotheunit.4. Push in Pilot Control Knobslightlyandturnclockwiseto“OFF”.5. Waitfive(5)minutestoclearoutanygas.Thensmellforgas,includingnearthefloor. • Ifyousmellgas,STOP!Follow“B”ontheSafetyInformationlabel. • Ifyoudon’tsmellgascontinueontothenextstep.6. Thepilotislocatedbythemainburner.7. Push in the Pilot Control Knobslightlyandturncounter-clockwiseto“Pilot”.8. Hold the Pilot Control Knobslightlyandturncounter-clockwiseto“Pilot”.9. ContinueholdingthePilot Control Knobforuptoone(1)minutebeforereleasing.Theknobwillpopbackoutupon release. Pilot should remain lit. If it goes out repeat steps 5 through 8. • Ifknobdoesnotpopoutwhenreleased,stopandimmediatelycallyourservicetechnician. • Ifthepilotwillnotstaylitafterseveraltries,turnthegascontrolknobto“OFF”andcallyourservicetechnician.10. Push in the Pilot Control Knobandturncounter-clockwiseto“ON”.11. It will take 2-3 minutes for thermocouple to heat up and flame to appear.12. ThisvalveisequippedwithaHI/LOfeature.Setunittodesiredflameheight.Thevalveisalsoequippedwitha safetylockoutfeaturethatwillpreventtherelightingofthepilotafteritisextinguished.Youmustwaitone(1)minute for valve to reset itself before relighting the pilot.13. Thenmoveswitchtoremote.Youwillthenbeabletoswitchtheunit“ON”or“OFF”usingtheremote.14. Tooperateunitwithremote: a. Makesureswitchisturnedto“REMOTE” b. MakesurePilot Control Knobisswitchedto“ON” c. Press button oncetoturnunit“ON”.Youwillhearasoftbeepthantheflamewillappear. d. Toturntheunit“OFF”.Pressthebuttonontheremoteonceafterfive(5)secondstheflamewilldisappearand theunitwillturnoff(NOTE:thepilotlightwillremainon).
Makesureswitchis turned to “OFF” whenlighting;and “REMOTE” to use
• PushthePilot Control Knob in fully and hold it in. • Immediatelylightthepilotwithamatch.ContinuetoholdthePilot Control Knobinforaboutone(1)minute. • Afterone(1)minute,releasetheknobanditwillpopbackout.Thepilotshouldremainlit.Ifitgoesout,repeat steps 2 through 8. • Ifthecontrolknobdoesnotpopoutwhenrelease,STOP and immediately call your service technician or gas supplier. • Ifthepilotwillnotstaylitafterseveraltries,turnthePilot Control Knobclockwiseto“OFF”andcallyourservice technician or gas supplier.
TO TURN GAS OFF TO APPLIANCE1. Turntheswitchto“OFF”2. Push in the Pilot Control Knobslightlyandturnclockwiseto“OFF”.DO NOT FORCE.
Page 9
IMPORTANT INFORMATIONMAINTENANCE OF THE SYSTEM- Undernormaluse,thisunitwillrequireonlylimitedcleaning.- Tocleantheunit,firstturnthePilotControlKnobto“OFF”andallowthesystemtocooldown.- Thelogsandgratecangetveryhot.Handleonlywhenthesystemiscool.- Keepthecontrolvalve,logsandburnerareacleanbyvacuumingorbrushingatleasttwiceayear.- Visuallyinspectthepilot.Dustorblowawayanydustorlintaccumulating.- Sufficientspacemustbeprovideddaroundthisappliancetoprovideairforcombustionandventilation.Keepthe front of the appliance clear of all obstacles and materials.- Donotstoreorusegasolineorotherflammablevaporsandliquidsinthevicinityofthisoranyotherappliance.- Duringthemanufacturingprocessthisapplianceistreatedwithcertaincoloringagents.Theseagentsarenot harmful,butmayproduceannoyingsmellandsmokeastheyareburnedoff.Thisisatemporaryoccurrencethat ceasesaftertwo(2)tothree(3)hoursofuse.
For further assistance, please contact our Customer Service Department at 800-229-5647
FINAL CHECKS
Things To Do:1. Useonlythetypeofgasforwhichyoursystemisdesigned.Thetypeofgasthesystemisequippedforisstamped on the rating plate.2. Install appliance and all gas piping according to local codes.3. Disconnect or isolate the system during line pressure testing.4. Makesure1/2”gaslineisruntothefireplacetoensuresufficientgasvolumetotheappliance.5. Installthesystemonlyinafireplacesuitableforburningsolidfuel.6. UsepipesealantonthreadedjointsofgaspipingthatisresistanttotheactionofLPgas.7. Installamanualshutoffvalve,unionand1/8”NPTpluggedpressuretapaheadofcontrols.8. Usemildsoapandwatersolutionwhencheckingforleaks.9. Keeptheareaaroundtheapplianceclearandfreeofcombustiblematerials,gasolineandanyflammable orexplosivematerial.10. Followthelightingandoperationproceduresgiveninthismanual.11. Periodicallyinspectthepilotandburnerflame.12. Clean the appliance as described in this manual.13. Keep the logs properly positioned.
Things NOT To Do:1. DoNOTmodifyoralterthisapplianceinanyway.2. DoNOTusethisappliancewithanygasotherthanthatforwhichitisequipped.3. DoNOTinstalltheapplianceinanyareawheregasolineoranyflammablematerialisusedorstored.4. DoNOTuseopenflametocheckforleaks.5. DoNOToperatethissystemwithglassdoorsintheCLOSEDposition.6. DoNOTblockorrestrictanygrillesofafactorybuildfireplaceinwhichtheapplianceisinstalled.7. DoNOTburnsolidfuelsinafireplacewherethisapplianceisinstalled.
Page 10
TROUBLESHOOTINGProblem Cause Corrective Action1. Nopilotignition -pilotvalvenoton • TurnvalvetoPILOTanddepress, keepmatchnearpilotburneruntil ignition.
-gaslinenotclear • Inspectsupplylinesfortubekinks or obstructions.
-airingasline • turnvalvetoPILOTanddepress,keep match near pilot burner until ignition.
Forrepair,replacement,orservicetodefectivepart/partspleasecontactourCustomerServiceHotlinenumberbelow.Thereafterwithvalidwarrantyregistrationandproofofpurchase,calltheCustomerService Hotline for authorization to ship defective part prepaid and insured in original carton to Sure HeatManufacturing,1861WestOakParkway,Marietta,GA30062.Goodsreturnedimproperlypackagedarethesoleresponsibilityofpurchaser.