    DRAWING NO. TITLE CUSTOMER LOCATION JOB #

    Page 1. of 3.

    Air Heaters

    B-12225 24" NDAH ( NAO Duct Air Heater ) Altair Filters International Altron, England 41941

    Flow 500 SCFM Temp 1,652F 900C (1989)

    Digital Temperature Control, Nema 12 Control

    Panel, Piping Train, UV Flame Scanner,

    Sightport, Direct Spark Ignition of Burner --

    Low Fire Start then Temperature Modulation

    B-9172 Hot Gas Generator ( Induced Draft ) Catalytic / FMC Lawrence, KS 18249

    Horizontal Air Heater -- 3 Units (1979)Flow 700 SCFM Temp 1,155F 630C

    Temperature Control with Thermocouple,

    Nema 3 Control Panel, IRI Piping Train,

    UV Flame Scanner, Sightport, Spark Ignited

    Pilot, Pneumatic Temperature Modulation

    C-7502 High Pressure Inline Heater -- 2 Units Industrial Electric-Automation Albuquerque, NM 49818Flow 5,250 SCFM Temp 550F 290C (1998 - 1983) 24354

    Temperature / flame safeguard control and

    pressure housing by customer.

    BURNER / PILOT / IGNITOR by NAO.

    High Energy Capacitor Discharge Ignition of

    Pilot NOTE: High voltage transformer will

    NOT spark above 30 psig (3 Atmospheres).

    A-11635 Rev. 5 Direct Fired Air Heater - Horizontal Geosafe Los Alamos, NM 50669

    Flow 3,600 SCFM Temp 160F 70C (1999)

    Nema 4 Control Panel, Piping Train,

    UV Flame Scanner, High Energy Capacitor

    Discharge Spark Ignited Pilot, Low Fire Burner

    Modulation

  • 7/25/2019 NAO Air Heater Collection

    9/15

    DRAWING NO. TITLE CUSTOMER LOCATION JOB #

    Page 2. of 3.

    B-8336 Rev. 3 NAH-5CH12 ( NAO Horizontal Air Heater ) US Industrial Chemical Deerpark, TX 14631

    Flow 2,000 SCFM Temp 1,900F 1,040C National Petrochemical Corp.

    Temperature Control with Thermocouple, (1976)

    Nema 7 (Explosionproof) Control Panel,

    Burner/Pilot Gas Piping Trains, Air Blower,UV Flame Scanner, Sightport, Spark Ignited

    Pilot, Pneumatic Air/Temperature Modulation

    A-9180 Rev. 4 NHAH ( NAO Horizontal Air Heater ) Jacobs Engineering Compton, CA 42618

    Flow 13,450 SCFM Temp 715F 380C (1989)

    Skid Mounted Unit with Nema 4 (Weatherproof)

    Control Panel, Temperature Control with TC,

    Burner/Pilot Gas Piping Trains (Double Block &

    Bleed per NFPA Code), Air Blower & Ducting,

    UV Flame Scanner, Sightport, Spark Ignited

    Pilot, Pneumatic Air/Temperature Modulation

    A-8852 NHAH-23.2C10-HI (High Temp) Valero Refinery Corpus Christi, TX 41106

    ( NAO Horizontal Air Heater ) (1988)

    Flow 29,800 Lb/Hr Temp 2,700F 1482C

    Retractable Gas Burner/High Pressure Spark

    Ignited Gas Pilot with Packing Glands &

    Isolation Valves, Sightport. CONTROLS and

    GAS TRAINS by customer.

    A-9061 Rev. 4 NHDFAH-25C32 International Paper Georgetown, SC 42099

    ( NAO Horizontal Direct Fired Air Heater ) (1989)

    Flow 13,000 SCFM Temp 1,400F 760C

    High Turndown JET MIX Burner, Retractable

    High Pressure Spark Ignited Gas Pilot with

    Packing Gland & Isolation Valve, Self-Checking

    UV Scanner, Sightport. OTHER CONTROLSand GAS TRAINS by customer.

  • 7/25/2019 NAO Air Heater Collection

    10/15

    DRAWING NO. TITLE CUSTOMER LOCATION JOB #

    Page 3. of 3.

    A-11543 Rev. 3 NHDFAH-8C20 Preheater / Reheater Paramount Petroleum Georgetown, SC 50250

    ( NAO Horizontal Direct Fired Air Heater ) (1999)

    Flow 77,266 Lb/Hr Flue Gas Temp 466F 230C

    Combustion Air Blower with Flue Gas DilutionDuct (NOx Reduction), High Turndown JET

    MIX Burner with Secondary Staged Fuel Tips

    for NOx Reduction, High Pressure Spark Ignited

    Gas Pilot , UV Scanner, Sightport.

    OTHER CONTROLS and GAS TRAINS by customer.

    A-9959 Rev. 5 NHDFAH-5.2C12 Celanese Mexicana Cangrejera, Mexico45068Sheets 1 & 2 of 2 ( NAO Horizontal Direct Fired Air Heater ) (1992)

    Flow 54,091 Lb/Hr Waste Gas

    Temp 800F 430C

    Retractable Gas Burner/High Pressure Spark

    Ignited Gas Pilot with Packing Glands &

    Isolation Valves, Sightport, Air Purged Self-Checking

    UV Scanner in Nema 7 (Explosionproof) Housing,Separate Control Skid with Nema 4 (Weatherproof)

    Control Panel, Temperature Control with TC,

    Burner/Pilot Gas Piping Trains (Double Block &

    Bleed per NFPA Code), and Pilot Air Train

    A-9200 Rev. 6 NHDFAH-5.2C12 ASME CODE Foster Wheeler / Fina Oil Port Arthur, TX 42659

    Sheet 1 of 2 ( NAO Horizontal Direct Fired Air Heater ) (1989)Flow 545,936 Lb/Hr Temp 1,400F 760C

    Cat Cracker Start-up Heater with High Turndown

    JET MIX Burner, Retractable High Pressure

    Spark Ignited Gas Pilot with Packing Gland &

    Isolation Valve, Air Purged Sightports & Self-Checking

    UV Scanner, Blast Connections for Removal of

    Catalyst, Trunnion for Free Floating Support toAllow Thermal Expansion