PA 2006 M New Castle, DE USA - Telephone: 1-302-427-4000 Paris, France - Telephone: 33-1-30-48-94-60 Brussels, Belgium - Telephone: 32-2-706-0080 Crawley, England - Telephone: 44-1-293-658900 Etten-Leur, Netherlands - Telephone: 31-76-508-7270 Eschborn, Germany - Telephone: 49-6196-400-600 Milano, Italy - Telephone: 39-02-27421-283 Tokyo, Japan - Telephone: 81-3-5479-8418 Barcelona, Spain - Telephone: 34-93-600-9300 Melbourne, Australia - Telephone: 61-3-9553-0813 Stockholm, Sweden - Telephone: 46-8-59-46-92-00 Tokyo, Japan - Telephone: 81-3-5479-8418 Beijing, China - Telephone: 8610-84518918 Shanghai, China - Telephone: 8621-63621888 Guangzhou, China - Telephone: 8620-86266678 Bangalore, India - Telephone: 91-80-28398963 TO CONTACT YOUR LOCAL TA INSTRUMENTS TECHNICAL REPRESENTATIVE VISIT OUR WEBSITE AT WWW. TAINSTRUMENTS . COM TA I NSTRUMENTS WORLDWIDE P RICE L IST Effective January 1, 2006 T HERMAL A NALYSIS AND R HEOLOGY A CCESSORIES , PARTS & S UPPLIES
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
970800.901 Pressure DSC Cell 16,600(For use with the Q2000 / Q20P and Q1000 / Q10P models. It provides heat flowmeasurements at pressures from 1 Pa to 7 Pa).
970814.901 Q Series PDSC Cell Shipping Accessory Kit 1,160(For use with PDSC Cell and Q2000 / Q1000 DSC)
900674.901 DSC Quench Cooling Accessory 1,130(For quench cooling of PDSC to -150°C using liquid nitrogen)
901600.901 Tzero Sample Press Kit 3,990(Includes a Tzero Press and die sets for Tzero aluminum pans; Tzero aluminum hermeticpans; Standard aluminum pans; Standard aluminum hermetic pans respectively. The kitalso includes one box each of Tzero aluminum pans (100) and lids (100)).
900680.902 Sample Encapsulation Press 2,580(For sealing of Standard Series Pans / Lids include High Volume Standard SS Pans / Lids and for sealing of TGA Aluminum Pans / Lids to be used in the Q5000 IR / Q5000 SA. This press is NOT compatible with the latest Tzero pans / lids)
935000.901 Photocalorimeter Accessory (PCA) 34,000(For use with the Q2000 / Q200 DSC and Q1000 / Q100 models to provide photocuringstudies between -50 & 250 °C.)
915064.901 MDSC® Thermal Conductivity Kit 990
970011.901 Accessory Kit, Q1000 / Q100 1,050
970011.902 Accessory Kit, Q10 1,050
Q Series DSC Cooling Accessories
970037.901 Finned Air Cooling System (FACS) 1,710(For programmed air cooling of Q Series DSC Cell from 725 °C to ambient temperature)
970036.901 Quench Cooling Accessory for FACS 1,170(Assists FACS in rapid cooling of Q Series DSC Cell to ambient temperature)
970008.901 Refrigerated Cooling System (RCS90) - 115 V / 60 Hz 9,980(For programmed or quench cooling of the Q Series DSC cell over the temperaturerange 550 to -90°C. Sealed refrigeration system does not require liquid nitrogen).
970008.902 Refrigerated Cooling System (RCS) - 230 V / 50 Hz 9,980
200266.001 RCS Dryer 400(For removal of trace moisture in purge gases)
970508.901 Refrigerated Cooling System (RCS40) - 115 V / 60 Hz 7,000(For programmed or quench cooling of the Q Series DSC cells over the temperaturerange from 400 to -40 °C. Sealed refrigeration system does not require liquid nitrogen.Requires a DSC with QNX module software).
970508.902 Refrigerated Cooling System (RCS40) - 230 V / 50 Hz. 7,000See above comments
970011.903 Accessory Kit, DSC AQ20 / Q20 (Supplied with the AQ20 / Q20 modules) 1,050
271580.001 Tweezers, Curved 40
971126.901 DSC Autosampler Tray 830
970830.901 DSC Autolid II Upgarde Kit (Optional Field Service installation recommended) 725
910824.001 Cell Cleaning Brush 30
DSC Sample Encapsulation
901600.901 Tzero Sample Press Kit 3,990(Includes Tzero Press and die sets for Tzero Aluminum pans; Tzero Aluminum Hermeticpans; Standard pans; Standard Hermetic pans respectively. Also includes one boxeach of Tzero Aluminum pans (100) and lids (100)).
901608.901 Replacement Tzero Standard Die Set 900
901608.902 Replacement Tzero Hermetic Die Set 900
901608.903 Replacement Standard Die Set 900
901608.904 Replacement Hermetic Die Set 900
Tzero Series DSC Sample Pans and Lids(Requires the Tzero Press (PN 901600.901))
Standard Series DSC Sample Pans and Lids(These pans / lids will operate with the Tzero Press or the older Standard Press)
900578.901 Platinum pans (package of 10) 1,300
900786.901 Aluminum pans (package of 200) 175
900779.901 Aluminum lids (package of 200) 175
900793.901 Aluminum pans, hermetic (package of 200) 250
900794.901 Aluminum lids, hermetic (package of 200) 250
900808.901 High pressure pan kit 2,990(includes metal bell jar & lid, crimping tool, 5 reusable SST capsules & 20 seals)
900814.901 High pressure capsule seals (package of 20) 240
900815.901 High pressure capsules (package of 5) 1,010
900825.901 High volume pan kit 3,710(Includes metal bell jar & lid, die set, and 100 pans, lids & seals)
4
200245.001 Pressure Regulator (use in USA only) 550(For use with the RCS Dryer or the LNCS Purge Gas Purifier Unit 4,000 psi input; 40 psi output; CGA)
970400.901 Liquid Nitrogen Cooling System (LNCS) 12,200(For programmed or quench cooling of the Q Series DSC Cells from 550 to -180 °C. It can be automatically refilled from an external LN2 source.
970425.901 LNCS DSC Purge Gas Purifier Unit 3,300(For removal of trace moisture in purge gases. Includes gas dryer unit and appropriateshut-off and by-pass valving)
970347.901 Quench Cooling Accessory (QCA) 1,610For rapid manual cooling of Q Series DSC Cell to subambient temperatures. If used with the Q2000 / Q200 or the Q1000 / Q100 modules the following parts must be added:
970442.001 Inner Manual Lid 160
970283.001 Outer Manual Lid 215
970284.901 Manual Cell Cover 230
Q Series™ Replacement DSC Cells (Replacement Q Series DSC cells do not include silver lids or accessory kits)
970020.901 User replacement Cell for Q2000 / Q1000 DSC 6,930
970520.901 Cell for Q200 / Q100 / AQ20 / Q20, / Q10 DSC modules; 6,410Requires separately priced installation by a TA Service Engineer.
Q Series DSC Field Upgrades
970003.901 Mass Flow Controller Upgrade Kit for Q100 / Q10 DSC 4,500(Includes Field Service Installation)
970004.901 MDSC® Upgrade Kit for Q200 / Q100 DSC 10,700(Includes Field Service Installation)
971000.901 Autosampler Upgrade Kit for Q200 / Q100 DSC 24,000(Includes Field Service Installation)
970777.901 Q2000 / Q200 Upgrade Kit 14,900(Upgrades the functionality of a Q1000 to a Q2000 or a Q100 to a Q200 respectively.The kit includes a Display Retrofit Kit to QNX, Nameplate kit, new Autosampler tray,Autolids Upgrade kit, Tzero Press Kit, and Tzero Hermetic pans and lids (1 box ofeach). Price includes field installation by a TA service engineer. Note: Some olderQ1000 / Q100 models may also need a separately priced upgrade of the Single Board Computer (SBC). Contact your TA Service engineer for information).
920247.901 Display Retrofit Kit to QNX 6,500(Kit that upgrades a Q1000 or Q100 to QNX operation with full VGA display capability.It includes Advantage Software with Platinum features. The price includes field installation by a TA Service engineer. Note: This kit requires other items (see kit PN970777.901) for more complete Q2000 / Q200 functionality. Some older Q1000 / Q100models may also need an upgrade of the Single Board Computer (SBC). Contact yourTA Service engineer for information).
7
935002.902 PCA Accessory Kit (replacement only) 7,500TA supplied items required for photocalorimeter operation by customer who already has, or will separately obtain, the Novacure 2100 analyzer and appropriate dual light guide.
935002.903 PCA Accessory Kit (replacement only) 10,500TA supplied items required for photocalorimeter operation by customer who already has, or will separately obtain, the Omnicure S-2000 analyzer and appropriate dual light guide.
200700.001 Radiometer (R2000) 3,000
935006.002 Filter, Internal, 250-450 nm 1,350
935006.001 Filter, Internal, 320-500 nm 1,220
935013.001 Air Filter Kit, Pkg of 10 110
935018.901 Filter, Longpass, 390 nm (Pkg of 2) 375
935019.901 Filter, Longpass, 490 nm (Pkg of 2) 375
935015.901 Filter, Neutral Density, 1 % 265
935016.901 Filter, Neutral Density, 10 % 265
935021.001 Lamp, 100 W, Mercury 1,670
935021.002 Lamp, 200 W, Mercury 1,830
Q5000 IR Accessories
900680.902 Sample Encapsulation Press 2,580(For sealing of Q5000 IR aluminum pans / lids as defined below; requires kit PN 957352.901)
957352.901 Aluminum sealed pan kit 1,990(Consists of 100 pans;100 lids, 30 bails, punch alignment tool; crimp die; crimping tool for use with the Sample Encapsulation Press - see above for part number)
957349.901 TGA / MS Interface Kit 3,500
957011.901 Accessory Kit, Q5000 IR (Supplied with the Q5000 IR module) 5,150
Q5000 IR Sample Pans
957207.903 Platinum sample pans, 50 µL (package of 3) 585
957207.904 Platinum sample pans, 100 µL (package of 3) 655
957329.903 Ceramic sample pans, 100 µL (package of 3) 550
957329.904 Ceramic sample pans, 250 µL (package of 3) 620
957363.901 Aluminum sample pans, 80 µL (package of 100) 345
957362.901 Aluminum Lids (package of 100) 440
957364.901 Stainess Steel Bail (package of 15) 275
957210.902 Kit Sample Pan Quartz (Pkg of 3) - Requires Autosampler Tray PN 957216.901 660
6
900824.901 High volume die set 1,230
900825.902 High volume pans, lids & seals (package of 100) 1,400
900860.901 Hermetic lids with pin hole (package of 50) 375
900796.901 Coated aluminum pans, hermetic (package of 200) 250
900790.901 Coated aluminum lids, hermetic (package of 200) 250
900870.901 Aluminum pans for SFI samples (package of 200) 140
900866.901 Gold pans (package of 10) 820
900868.901 Gold lids (package of 10) 820
900871.901 Gold pans, hermetic (package of 10) 1,150
900872.901 Gold lids, hermetic (package of 10) 820
900867.901 Copper pans (package of 200) 140
900874.901 Graphite pans (package of 10) 355
900873.901 Graphite lids (package of 10) 355
DSC Calibration Materials
970345.901 Kit, Tzero Calibration, Sapphire 175
970370.901 Sapphire, MDSC Calibration 325
915060.901 DSC / DTA temperature calibration kit 1,580
960034.901 Aluminum oxide reference material (calcined alpha) 65
952540.901 TGA / SDT Mass Loss Reference Materials Kit 1,760(Includes 1 gm each of the three material listed below)
952524.901 Mass Loss Reference Material (2% solution) 640
952528.901 Mass Loss Reference Material (49% solution) 640
952532.901 Mass Loss Reference Material (98% solution) 640
960234.901 Zinc Calibration Material 50
900905.901 Calcium oxalate 60
TMA Q400 / 400EM Accessories and Upgrade Kits
944300.901 Mechanical Cooling Accessory (115 V operation) 8,830(For programmed or quench cooling of the Q400/Q400EM/2940 over temperaturerange 400 to -60°C. Sealed refrigeration system does not require liquid nitrogen).
944300.902 Mechanical Cooling Accessory (230 V operation) 8,830
945050.901 TMA Film/Fiber Accessory Kit 3,070(Consisting of film / fiber sample stage, film / fiber probe assembly, vial of cleaved aluminum balls, film clamp assemblies, film clamp fixture, jeweler's screwdriver, and film clamp screws)
944202.901 Dilatometer Accessory Kit 2,500(Consisting of dilatometer probe assembly, three dilatometer sample vials, two vials offilling medium, and a vial of aluminum calibration standard)
952541.901 TGA / SDT ICTAC Curie Point Reference Materials Kit 1,760(Includes 0.5 g each of the six ICTAC certified material listed below)
952541.902 TGA / SDT ICTAC Curie Point Reference Materials Kit for Q5000 IR 1,600(Includes 0.5 g each of the six ICTAC certified material listed below)
952500.901 Replacement ICTAC Certified Curie Point Reference Material 153°C 640
952504.901 Replacement ICTAC Certified Curie Point Reference Material 357°C 640
952508.901 Replacement ICTAC Certified Curie Point Reference Material 554°C 640
952512.901 Replacement ICTAC Certified Curie Point Reference Material 746°C 640
952516.901 Replacement ICTAC Certified Curie Point Reference Material 931°C 640
952520.901 Replacement ICTAC Certified Curie Point Reference Material 1116°C 640
985068.901 Submersion Film / Fiber Tension Clamp Kit 8,290
985069.901 Three Point Bend Clamp Kit (50 mm, Low Friction) 3,160
985070.901 Three Point Bend Clamp Kit (20 mm, Low Friction) 3,300
984486.901 Film Cutting Kit 740
Q800 DMA Replacement Parts
984003.901 Replacement Furnace 4,710
259508.000 Brass tweezers 65
270962.001 Telescoping gage (for 10 mm single cantilever clamps) 95
270962.002 Telescoping gage (for 17 mm single cantilever clamps) 125
985199.901 Control thermocouple (90 mm length) 205
985199.902 Sample thermocouple (130 mm length) 205
984370.901 Furnace inlet ferrule / spring kit 40
270976.002 Filter / Regulator with Auto Drain 1,350
270975.001 Filter Replacement, Auto Drain Regulator 85
Q800 DMA Calibration and Test Materials
12
(Consisting of rheometer sample-forming die set, three rheometer alignment cages, and six rheometer parallel plates)
270134.001 Flow Meter 460For purge gas regulation (14.8 to 148 mL / min) of earlier TMA Q400 / 400EM withoutmass flow control. A digital mass flow controller upgrade is highly recommended -contact TA Service)
944200.901 Accessory Kit Q400 (Supplied with Q400 / Q400 EM modules) 5,000Note: the Flexure Accessory Kit (PN 944203;901) is also supplied with the Q400 EM; a customer wanting to replace the entire Q400 EM Accessory Kit must purchase PN 945250.901 and PN 945203.902.
Replacement 2910 DSC Cells (Accessory kits and instruction manuals not supplied)
900610.905 Replacement Standard DSC Cell - 2910 4,970
900610.920 Replacement Standard DSC-RCS Cell - 2910 4,970
Replacement DSC 2010 Cell
911306.901 Replacement DSC Cell - 2010 (Requires installation by TA Service Engineer) 5,020
DSC 2920 and DSC 2910 Accessories
900674.901 DSC Quench Cooling Accessory 1,130(For programmed cooling operation to -120 °C, and quench cooling to -180 °C. using liquid nitrogen. Includes bell jar, O-ring, and thermal resistor disc)
900680.902 Sample Encapsulation Press 2,580(For crimp and hermetic pan sealing of Standard Series pans / lids. Also required foruse with the High Volume Pans / Lids. Limited availability)
14
980228.902 Glass support cloth (0.2 mm thick, 33 m length) 370
982161.902 ABS sample (3.18 mm thick, 61 mm long, pkg of 5) 50
982161.903 ABS sample (3.18 mm thick, 36 mm long, pkg of 5) 50
982165.903 Polycarbonate sample (1.6 mm thick, 36 mm long, pkg of 5) 50
982165.904 Polycarbonate sample (0.79 mm thick, 36 mm long, pkg of 5) 50
984309.901 Polyethylene terephthalate (PET) film (pkg of 10 pieces, 38 mm long) 50
984313.901 PET fiber (910 mm long) 50
RSA III Temperature Options
403164.901 FCO Mechanical Chiller Panel 7,700NOTE: Requires Customer to Purchase Polycold PGC 152 mechanical Chiller directlyfrom Polycold
402020.951 Waveform and Fast Sampling Option Upgrade (For ARES V5, V6, or V8) 5,240
RSA III DETA: Dielectric Thermal Analysis OptionNOTE: Hewlett Packard #HP4284A LCR Meter is model provided with DETA options including a bridge. Customers mustsupply this bridge if purchasing option without bridge included.
700.02903.4 RSA III Dielectric Thermal Analysis Option, Includes Bridge, 34,200120 VAC 60 HzNOTE: Includes HP4284A LCR Meter and 25 mm Parallel Plates.
700.02903.5 RSA III Dielectric Thermal Analysis Tooling, Bridge Not Included, 12,600120 VAC, 60 HzNOTE: Includes 25 mm Parallel Plates & Interface for customer supplied HP4284ABridge.
Fixtures
708.01456 Three-Point Bending Fixture 2,300
708.01446 Cantilever Bending Fixture 2,920
708.01455 Film/Fiber Fixture 2,300
708.01464 Parallel Plate Fixture 2,920
708.01466.1 8 mm Plates for Parallel Plate Fixture 500
17
DSC Replacement Parts
900155.000 Bell jar for DSC Cells 205
900681.002 Bell jar for DSC Cooling Accessory 305
900530.901 Upper crimping die set assembly 615
900752.901 Lower crimping die assembly 535
258825.000 Spring for lower crimping die 8
900720.000 Die, hermetic sealing 150
900719.000 Preforming tool. For hermetic pans (Beige Press) 120
910824.001 DSC Cell fiberglass cleaning brush 30
900635.000 Silver lid (standard cell) 235
991123.001 Silver Inner lid # 1 (RCS cell) 285
990687.001 Cell Lid, Silver w/Hole #2 285
990686.002 Lid Cooling Can SST # 2 55
990686.001 Lid, Aluminum # 3 55
900969.001 Silver lid (pressure DSC cell) 280
DSC Calibration Materials
915060.901 DSC / DTA temperature calibration kit 1,580
900786.901 Aluminum pans, standard (package of 200) 140
900779.901 Aluminum lids, standard (package of 200) 140
900793.901 Aluminum pans, hermetic (package of 200) 210
900794.901 Aluminum lids, hermetic (package of 200) 210
900867.902 Auto DSC sample pans, copper (package of 200) 235
16
270134.001 Flow Meter 460For purge gas regulation (14.8 - 148 mL / min. air). Stainless steel float, R-2-15-AAAtube, valve location at inlet, In / Out connections at back, brass fittings for 1/4 inch(6.35 mm) I.D. hose, tripod base with level. Also includes 25 feet (7.64 m) of 1/4 inch(6.35 mm) tygon tubing.
270134.002 Dual Flow Meter 690For purge gas regulation (14.8 - 148 mL / min. air). Stainless steel floats, two R-2-15-AAA tubes, valve location at inlet, In / Out connections at back, brass fittingsfor 1/4 inch (6.35 mm) I.D. hose, tripod base with level. Also includes 25 feet (7.64 m) of 1/4 inch (6.35 mm) tygon tubing.
992300.901 Gas Switching Accessory 3,650(Automatically switches between two purge gases with manual override)
Standard Series DSC Sample Pans and Lids
900578.901 Platinum pans (package of 10) 1,300
900786.901 Aluminum pans (package of 200) 175
900779.901 Aluminum lids (package of 200) 175
900793.901 Aluminum pans, hermetic (package of 200) 250
900794.901 Aluminum lids, hermetic (package of 200) 250
900808.901 High pressure pan kit 2,990(includes metal bell jar & lid, crimping tool, 5 reusable SST capsules & 20 seals)
900814.901 High pressure capsule seals (package of 20) 240
900815.901 High pressure capsules (package of 5) 1,010
900825.901 High volume pan kit 3,710(Includes metal bell jar & lid, die set, and 100 pans, lids & seals)
900824.901 High volume die set 1,230
900825.902 High volume pans, lids & seals (package of 100) 1,400
900860.901 Hermetic lids with pin hole (package of 50) 375
900796.901 Coated aluminum pans, hermetic (package of 200) 250
900790.901 Coated aluminum lids, hermetic (package of 200) 250
900870.901 Aluminum pans for SFI samples (package of 200) 140
900866.901 Gold pans (package of 10) 820
900868.901 Gold lids (package of 10) 820
900871.901 Gold pans, hermetic (package of 10) 1,150
900872.901 Gold lids, hermetic (package of 10) 820
900867.901 Copper pans (package of 200) 140
900874.901 Graphite pans (package of 10) 355
900873.901 Graphite lids (package of 10) 355
19
952018.909 Ceramic sample pans, 250 µL (package of 3) 600
952018.910 Ceramic sample pans, 500 µL (package of 3) 690
952323.902 Aluminum sample pans, 100 µL (package of 12) 180
TGA 2950 / 2050 Replacement Parts
259508.000 Brass tweezers 65
952011.906 Set of class M weights (100 mg, 1 g) 1,010
952013.982 Rebuilt TGA 2950 furnace 5,220
952013.980 Damaged Furnace Exchange Credit 1,240
952040.901 Sample hang-down wire 75
952040.902 Tare hang-down wire 75
952068.901 Sample thermocouple 180
952121.001 Work surface tray 180
952011.901 Accessory Kit, TGA 2950 2,840
952110.001 Tube, Hangdown Wire 65
952160.901 Heat Exchanger, TGA 2950 3,020
952240.901 Auto TGA 2950 multiple sample tray kit 1,060
952256.901 Kapton® hangdown loop (strip of 10) 95
952357.901 Furnace tube (quartz) / Seals kit / Instructions for EGA furnace 840
900710.901 Platinum micro sample cups (package of 4) 1,240
900713.901 Platinum macro sample cups (package of 4) 1,280
900711.901 Platinum macro sample cap liners (package of 10) 720
900712.901 Alumina macro sample cup liners (package of 6) 455
900906.901 Aluminum oxide reference material 65
TGA 2950 / 2050 Accessories & Field Upgrades
952431.901 Evolved Gas Furnace (EGA) for TGA 2950 / 2050 4,270Recommended for evolved gas analysis with MS or FTIR. Requires installation by TA Service Staff
852352.901 Evolved Gas Furnace (EGA) for TGA 2950 / 2050 - CE Compliant 7,700Recommended for evolved gas analysis with MS or FTIR. Requires installation by TA Service Staff
270134.901 Flow Meter 460For purge gas regulation (14.8 - 148 mL / min. air). See page 9 for full description
270134.002 Dual Flow Meter 690For purge gas regulation (14.8 - 148 mL / min. air). See page 9 for full description.
992300.901 Gas Switching Accessory - CE Compliant 3,650Automatically switches between two purge gases with manual override provided.Compatible with the TGA 2050, TGA 2950, and SDT 2960.
TGA 2950 / 2050 Sample Pans
952018.906 Platinum sample pans, 100 µL (package of 3) 655
952018.907 Ceramic sample pans, 100 µL (package of 3) 540
952018.908 Platinum sample pans, 50 µL (package of 3) 560
960034.901 Aluminum oxide reference material (calcined alpha) 65
952540.901 TGA / SDT Mass Loss Reference Materials Kit 1,760(Includes 1 gm each of the three material listed below)
952524.901 Mass Loss Reference Material (2% solution) 640
952528.901 Mass Loss Reference Material (49% solution) 640
952532.901 Mass Loss Reference Material (98% solution) 640
900905.901 Calcium oxalate 60
960234.901 Zinc Standard Material 50
960014.901 Calibration weights set 195
TMA 2940 Accessories
944300.901 Mechanical Cooling Accessory (115 V operation) 8,830For programmed or quench cooling of the TMA 2940 over temperature range 400 to -60 °C. Sealed refrigeration system does not require liquid nitrogen.
944300.902 Mechanical Cooling Accessory (230 V operation) 8,830
945050.901 Film/Fiber Accessory Kit 3,070(Consisting of film / fiber sample stage, film / fiber probe assembly, vial of cleavedaluminum balls, film clamp assemblies, film clamp fixture, jeweler's screwdriver (2 mm), and ten film clamp screws (#0-80))
944202.901 Dilatometer Accessory Kit 2,500(Consisting of dilatometer probe assembly, three dilatometer sample viles, two vials offilling medium, and a vial of aluminum calibration standard)
944204.901 Parallel Plate Rheometer Accessory Kit 2,960(Consisting of rheometer sample-forming die set, three rheometer alignment cages,and six rheometer parallel plates)
270134.001 Flow Meter 460For purge gas regulation (14.8 - 148 mL / min. air).
TMA 2940 Replacement Parts
944120.901 Sample stage 655
944122.901 Expansion probe assembly 1,520
944123.901 Macro-expansion probe assembly 1,520
944124.901 Dilatometer probe assembly 1,520
941143.000 Dilatometer sample vile 210
944125.901 Hemispherical probe assembly 1,520
944126.901 Penetration probe assembly 1,520
20
952528.901 Mass Loss Reference Material (49% solution) 640
952532.901 Mass Loss Reference Material (98% solution) 640
900905.901 Calcium oxalate 60
SDT 2960 Accessories
270134.001 Flow Meter 460For purge gas regulation (14.8 - 148 mL / min. air). Stainless steel float, R-2-15-AAAtube, valve location at inlet, In / Out connections at back, brass fittings for 1/4 inch(6.35 mm) I.D. hose, tripod base with level. Also includes 25 feet (7.64 m) of 1/4 inch(6.35 mm) tygon tubing.
270134.002 Dual Flow Meter 690For purge gas regulation (14.8 - 148 mL / min. air). Stainless steel floats, two R-2-15-AAA tubes, valve location at inlet, In / Out connections at back, brass fittings for 1/4 inch (6.35 mm) I.D. hose, tripod base with level. Also includes 25 feet (7.64 m) of 1/4 inch (6.35 mm) tygon tubing.
992300.901 Gas Switching Accessory - CE Compliant 3,650(Automatically switches between two purge gases with manual override)
SDT 2960 Sample Pans
960070.901 Alumina sample cups; 90 µL (package of 3) 130
960072.901 Alumina sample cups;40 µL (package of 3) 130
960148.901 Platinum sample cups; 40 µL (package of 3) 260
960149.901 Platinum sample cups; 110 µL (package of 3) 350
960239.901 Alumina lids; package of 3 (for use with p/n 960070.901) 75
984449.901 Submersion Film / Fiber Tension Clamp Kit 3,980
984486.901 Film Cutting Kit 740
DMA 2980 Replacement Parts
259508.000 Brass tweezers 65
270962.001 Telescoping gage (for 10 mm single cantilever clamps) 95
270962.002 Telescoping gage (for 17 mm single cantilever clamps) 125
984370.901 Furnace inlet ferrule / spring kit 40
984074.001 Compression Disc (40 mm) 285
984075.001 Compression Disc (15 mm) 45
984278.001 Service manual, DMA 2980 345
270976.001 Filter / Regulator with Auto Drain 1,350
270975.001 Filter Replacement, Auto Drain Regulator 85
980228.902 Glass support cloth (0.205 mm thick, 32.92 m length) 370
984287.901 Control thermocouple (89 mm length) 190
984286.901 Sample thermocouple (130 mm length) 190
DMA 2980 Calibration and Test Materials
982161.902 ABS sample (3.18 mm thick, 61 mm long, pkg of 5) 50
982161.903 ABS sample (3.18 mm thick, 36 mm long, pkg of 5) 50
982165.903 Polycarbonate sample (1.59 mm thick, 36 mm long, pkg of 5) 50
982165.904 Polycarbonate sample (0.79 mm thick, 36 mm long, pkg of 5) 50
984309.901 Polyethylene terephthalate (PET) film (pkg of 10 pieces, 38 mm long) 50
984313.901 PET fiber (910 mm long) 50
DEA 2970 Accessories and Replacement Parts
270134.003 Flow Meter 460For purge gas regulation (0.16-1.7 L / min. air). SS float, valve location at inlet, In /Out connections at back, brass fittings for 1/4 inch (6.35 mm) Id. hose, tripod basewith level. Includes 25 feet (6.7 m) of 1/4 inch (6.35 mm) tygon tubing).
901315.901 Parallel Plate Ram Kit (range -150 to 500 °C) 4,250Accessory kit contains a parallel plate assembly, 10 bottom parallel plate sensors, 10top parallel plate sensors, 20 sets of drip pans, 30 spring probes, reference samplesand tweezers.
901316.901 Single Surface Ram Kit (range -150 to 500 °C) 4,250Accessory kit contains a single surface ram assembly, 10 single surface sensors,20 sets of drip pans, 60 pointed spring probes, reference samples and tweezers.
901402.901 Sputter Coated (thin film) Accessory Kit (range -150 to 500 °C) 1,740Accessory kit contains 10 bottom parallel plates, 10 top parallel thin film sensors, sputter coated mask, 20 sets of drip pans, PET reference samples, and tweezers.
926205.802 Upgrade Kit Advantage Software 1,500(Upgrades 29XX modules, using OS/2 and Thermal Solutions software to the latestversion of Advantage software. Some 29XX modules may also need a GPIP boardupgrade - contact your TA Representative for information and pricing).
925003.901 HP Color Inkjet Printer - 115 V / 60 Hz 550
925003.902 HP Color Inkjet Printer - 230 V / 50 Hz 570
General Information
Minimum order requirements: $100. All prices f.o.b. shipping point. Prices and specifications arethose in effect at the time of printing and are subject to change without notice. International pricesare additional in most countries. All orders are subject to final acceptance.N
27
403017.901 ARES Photo-Curing Option: 14,700Accessory for rheological characterization of UV curable materials.Includes upper tool with removable 20 mm quartz plate, lower disposabletool, with 20 mm stainless steel plate (for ambient operation), light source mount and collimator, polycarbonate UV light Shield, 5 mmlight guide, remote radiometer/dosimeter, Waveform & Fast Samplinginterface cable for triggering light source (for Exfo Novacure only), two pair UV safety glasses, trimming tool. Optional disposable acrylicupper and aluminum lower plates are available for rigid UV coatings.Option can be used with the ARES Peltier Plate (-30°C to 150°C) and Bath(-10°C to 140°C) temperature control systems for samples that can beremoved after curing.Notes: Accessory does not include UV light source. Customer must supply ExfoNovacure UV light source separately to interface with option. Necessary data acquisition rates, and light source shutter and exposure time control trigger, are onlyavailable when option used with ARES Waveform and Fast Sampling Option (part# 402020.901 or 402020.951). Minimum instrument requirements: Orchestratorversion 7.0, ARES firmware version 8 or 15.
403017.902 ARES UV-Curing Option: 36,000Accessory for rheological characterization of UV curable materials.Includes Exfo Novacure UV light source with high-pressure mercury lampand built-in radiometer, upper tool with removable 20 mm quartz plate,lower disposable tool with 20 mm stainless steel plate (for ambient operation), light source mount and collimator, polycarbonate UV lightShield, 5 mm light guide, remote radiometer & dosimeter, Waveform &Fast Sampling interface cable for triggering light source, two pair UV safety glasses, trimming tool. Optional disposable acrylic upper andaluminum lower plates are available for rigid UV coatings. Option can beused with the ARES Peltier Plate (-30°C to 150°C) and Bath (-10°C to140°C) temperature control systems for samples that can be removedafter curing.Notes: Necessary data acquisition rates, and light source shutter and exposure timecontrol trigger, are only available when option is used with ARES Waveform and FastSampling Option (part# 402020.901 or 402020.951). Minimum instrument requirements:Orchestrator version 7.0, ARES firmware version 8 or 15.
ARES UV & Photo-Curing Accessories
403153.001 Upper 20 mm Quartz Plate for ARES-UV Option 340Note: For use with ARES-UV Curing Option and Photo-curing Option upper plate fixture.
403171.002 Lower 20 mm Stainless Steel Plate for ARES-UV Option 50Note: For use with ARES-UV Curing and Photo-curing Option upper quartz plate and fixture.
403064.901 Package of 10 disposable 20 mm diameter acrylic plates 310for use with ARES-UV Curing Option and Photo-curing Option upper platefixture.Note: Not for use with standard disposable plate fixture.
403065.901 Package of 10 disposable 20 mm aluminum plates 310for ARES disposable plate fixture. Note: For use with ARES-UV Curing and Photo-curing Option upper quartz plate and fixture
26
ARES Rheometers
ARES Temperature Control Options Price US $ / €
700.03382.6 FCO Liquid Nitrogen Controller Option for ARES V6 and V8 Only 16,300
403164.901 FCO Mechanical Chiller Panel 7,700NOTE: Requires Customer to Purchase Polycold PGC 152 mechanical Chiller directlyfrom Polycold
700.03382.8 Sealed Recirculating Fluids Bath 10,400NOTE: Requires ARES Computer Controlled Circulator (Part#'s 700.02750.3 or403197.902) for temperature control
403197.901 ARES Computer Controlled Circulator, 110 VAC, 60 Hz 6,880NOTE: Use for temperature contorl of Sealed Recirculating Bath, 700.03382.8
403197.902 ARES Computer Controlled Circulator, 230 VAC, 50 Hz 6,880NOTE: Use for temperature contorl of Sealed Recirculating Bath, 700.03382.8
402020.951 Waveform and Fast Sampling Option Upgrade (For ARES V5, V6, or V8) 5,240
700.02945.1 Optical Analysis Module, OAM II 35,900NOTE: Requires Optical Parallel Plate or Couette Separately. Adjustable height supportrequired for FCO systems used with OAM II (part# 700.03336)
708.01442 Optical Parallel Plate; includes: 5,79038.1 mm upper and lower glass parallel plates for use with OAMII
708.01439 Optical Couette Kit; includes: 12,60030 mm OD Upper stainless bob and 34 mm ID stainless/glass cup; for use with OAMIIat ambient use only; requires V5.xx.xx or higher firmware and 2KFRTN1 transducer
700.03336 OAMII Adjustable FCO Height Support 1,840
700.03188.1 Electro-Rheological Analysis Option for 2KFRT Transducers 31,300
700.03188.4 Electro-Rheological Analysis Option for 1KFRT Transducers 31,300
Rheometers
29
Stainless Steel Upper Cones for Force Convection OvenNOTE: Requires Lower Plate of same diameter.
708.00961 Stainless Steel, 25 mm 0.02 rad Cone (1.146 deg) 1,630
708.00962 Stainless Steel, 25 mm 0.04 rad Cone (2.29 deg) 1,630
708.01003 Stainless Steel, 25 mm 0.1 rad Cone (5.73 deg) 1,630
708.00963 Stainless Steel, 50 mm 0.02 rad Cone (1.146 deg) 1,660
708.00964 Stainless Steel, 50 mm 0.04 rad Cone (2.29 deg) 1,660
Titanium Upper Cones for Bath, Peltier Plate, & Force Convection OvenNOTE: Requires Lower Plate for Temperature Control System of Interest.
708.00954 Titanium, 25 mm 0.02 rad Cone (1.146 deg) 1,940
708.00959 Titanium, 25 mm 0.04 rad Cone (2.29 deg) 1,940
708.01004 Titanium, 25 mm 0.1 rad Cone (5.73 deg) 1,290
708.00955 Titanium, 50 mm 0.02 rad Cone (1.146 deg) 1,970
708.00960 Titanium, 50 mm 0.04 rad Cone (2.29 deg) 1,970
708.01031 Titanium, Upper Disposable Plate Fixture 2,320NOTE: Recommended for ARES-LS1 and ARES-RFS w/1KFRT Transducer
700.02648 Disposable Plate Sample Mold, A Six cavity stainless steel mold 3,220for use with disposable 25 mm plates. Molds 6.35 mm thick samples andis specifically designed for molding elastomers
ARES DETA: Dielectric Thermal Analysis OptionsNOTE: Hewlett Packard #HP4284A LCR Meter is model provided with DETA options including a bridge. Customers mustsupply this bridge if purchasing option without bridge included.
700.02903 ARES Dielectric Thermal Analysis Option, 34,200Includes Bridge,120 VAC 60 HzNOTE: Includes HP4284A LCR Meter and 25 mm Parallel Plates.
700.02903.1 ARES Dielectric Thermal Analysis Tooling, 12,800Bridge Not Included, 120 VAC, 60 HzNOTE: Includes 25 mm Parallel Plates & Interface for customer supplied HP4284A Bridge.
700.02903.3 ARES Dielectric Thermal Analysis Tooling, 12,800Bridge Not Included, 220 VAC, 50 HzNOTE: Includes 25 mm Parallel Plates & Interface for customer supplied HP4284A Bridge.
Stainless Steel Parallel Plates Sets for use with Force Convection OvenNOTE: Titanium Upper Tools Required fro ARES-LS1 and ARES-RFS
708.01517 Stainless Steel, 8 mm Parallel Plate Set; upper and lower 2,570
708.00966.1 Stainless Steel, 25 mm Parallel Plate Set; upper and lower, 2,900Includes melt ring
708.01081 Stainless Steel, 40 mm Parallel Plate Set; upper and lower 3,320
708.00968.1 Stainless Steel, 50 mm Parallel Plate Set; upper and lower 2,390
708.00972.1 Stainless Steel, Serrated 25 mm Parallel Plate Set; upper and lower 3,560
Individual Stainless Steel Parallel Plates for Force Convection Oven
708.00965.U Stainless Steel, 25 mm Upper Plate 1,200
708.00965.L Stainless Steel, 25 mm Lower Plate 1,310
708.00967.U Stainless Steel, 50 mm Upper Plate 1,070
708.00967.L Stainless Steel, 50 mm Lower Plate 1,200
Titanium Parallel Plates for Bath, Peltier Plate & Force Convection OvenNOTE: Titanium Upper Geometries are Required for use with ARES-LS1 & ARES-RFS configured with1KFRT Transducer.
708.00952 25mm upper parallel plate; titanium 1,940NOTE: Can use in FCO with lower 25 mm Stainless Steel Fixture, part#708.00965.L
708.00953 50mm upper parallel plate; titanium 1,970NOTE: Can use in FCO with lower 50 mm Stainless Steel Fixture, part#708.00967.L
Invar Parallel Plates/Cones for Force Convection Oven
708.01026.1 Invar, 8.0 mm Parallel Plate Set; upper and lower 3,010
708.01020.1 Invar, 25 mm Parallel Plate Set; upper and lower 2,740
708.01023.1 Invar, 50 mm Parallel Plate Set; upper and lower 3,100
708.01042 Invar, 25 mm 0.1 rad Cone (5.73 deg) 1,070
708.01440 Linear Tack Testing Tool for use with ARES and FRTN transducers 2,300
708.01458 Linear Film/Fiber Testing Tool; for use with ARES and FRTN 2,300transducers (stress/strain)
708.00991 Film/Fiber Testing Tool; for dynamic testing of films using 2KFRT transducer 3,870
708.01121.1 27 mm Ambient Couette Testing Package; 6,050For ambient testing of fluids on ARES without fluids bath, includes: 25mm Diameter Titanium Bob (part# 401.00710.3) 27 mm DiameterStainless Cup (part# 401.00709.20 and PRT)
401.00710.3 Replacement 25 mm titanium bob 2,550
ARES Testing Packages and Sample PreparationNOTE: Testing packages offer sets of tools and accessories for specific applications.
708.01333.2 Advanced Melt Add-On Package; 6,100Includes: Designed for use with Melt Rheology Starter Package StainlessSteel 50 mm Parallel Plate Set (part#708.00968.1) Stainless Steel 25 mmSerrated Plate Set (part#708.00972.1) Stainless Steel 50 mm 0.04 radCone (part#708.00964)
708.01333.3 Thermoset Testing Package; 5,900Includes: Torsion Retangular Fixture (part#708.01495) Disposable PlateFixture (part#708.01015) One Pair 8 mm Aluminum Disposable Plates OnePair 25 mm Aluminum Disposable Plates
708.01476 Fluid Rheology Starter Package for Sealed Bath (Version 2); 6,800Includes: Mixed Metal, 50 mm Titanium Upper & Stainless Lower ParallelPlate Set (part#708.01470),Titanium Upper 50 mm 0.04 rad Cone (part #708.00960) 34 mm Couette Testing Package (part #708.01473)
30
700.02678 Aluminum, 42 mm Disposable Cup, 1 piece 120
401.00756 Combined Melts/Solids Upper Plate; 1208mm and 25mm testing surfaces; for Asphalt Testing use with 708.01015and 700.02678
Aluminum Disposable Cones
700.02451.2 Aluminum, 25 mm 0.02 rad Disposable Cone; 10 pieces 440
700.02451.1 Aluminum, 25 mm 0.1 rad Disposable Cone; 10 pieces 440
700.02451.3 Aluminum, 50 mm 0.04 rad Disposable Cone; 10 pieces 440
Insulated Polyphenylene Sulfide (PPS) Plates and Cones for use with Peltier Plate & BathNOTE: PPS Geometries provide thermal insulation for Peltier and Bath heating systems. Maximum use temperature forthe PPS geometries is 150 °C. Stainless Steel and Titanium Upper Geometries can also be used w/Peltier and Bath.
708.01412 Peltier Shear Testing Tool Set, with Polyphenylene Sulfide (PPS) 3,370Upper Cones and Plates on Stainless Steel Shaft, Max Temp = 150 °C.Set Includes: 25 mm & 50 mm Plates, 25 mm 0.1 rad Cone, & 50 mm 0.04 rad Cone
ARES Sealed Bath Plates and Cones NOTE: Sealed lower bath tools are threaded and screw into ARES Bath and are NOT compatible with older tapered style Bath (Version 1).
708.01469 Mixed Metal, 25 mm Titanium Upper & Stainless Lower Parallel Plate Set 2,490
708.01470 Mixed Metal, 50 mm Titanium Upper & Stainless Lower Parallel Plate Set 2,630
708.01471 Stainless Steel, 25 mm Lower Plate for ARES Sealed Bath 1,450
708.01472 Stainless Steel, 50 mm Lower Plate for ARES Sealed Bath 1,560
ARES Sealed Bath Concentric Cylinders Packages and Geometries NOTE: Sealed lower bath tools are threaded and screw into ARES Bath and are NOT compatible with older tapered styleBath (Version 1).
708.01473 34 mm Couette Testing Package; 2,850Includes: 32 mm dia. Titanium Bob w/Recessed End (part# 401.00600.3) 34 mm dia.Stainless Steel Cup (part#400.10949)
400.10949 Stainless Steel 34 mm Diameter Replacement Cup for Sealed Bath 1,640
401.00600.3 Titanium, 32 mm Diameter replacement Recessed End Bob for Sealed Bath 1,630
708.01474 17 mm Couette Testing Package; 2,850Includes: 16.5 mm dia. Titanium Bob w/Recessed End (part# 401.00614.1) 17 mm dia.Stainless Steel Cup (part#401.01286)
401.01286 Stainless Steel 17 mm Diameter Replacement Cup for Sealed Bath 1,560
708.01475 Double Wall Couette Package; 5,750includes: 34 mm OD/27.95 mm ID stainless cup 32 mm OD/29.5 mm ID titanium bob
708.01228 Stainless Steel 18 mm Vane Fixture 2,510(for Use with 34 mm Stainless Steel Cup part#400.10949)
545801.901 AR2000 Upper Heated Plate System (for use with Peltier Plate) 7,250Note: AR2000 Instruments with serial numbers prior to 4F…. will require UHP MountingKit & Installation, part#545805.901, at an additional cost of $1,900.00 (price includesinstallation by TA Service Engineer). Option requires Rheology Advantage v5.1 (P/N 595120.801).
545802.901 AR2000 Dry Asphalt system 8,850Note: AR2000 Instruments with serial numbers prior to 4F…. will require UHP MountingKit & Installation,
545808.901 AR-G2 & AR2000 UHP & Dry Asphalt Low Temperature Cooloing Option 690Note: This cooling option is required when cooling with fluid circulator below temperatures of 5°C. Customer must supply fluid circulator.
545807.901 AR-G2 & AR2000 UHP & Dry Asphalt Standard Cooloing Option 990Note: This cooling option is required when cooling with fluid circulator above temperatures of 5°C. Customer must supply fluid circulator.
545809.901 AR-G2 &AR2000 UHP and Dry Asphalt Vortex Cooler 1,470NOTE: Requires Low Temperature Cooling Option part# 545808.901
Peltier Concentric Cylinder Jacket for AR-G2 & AR2000 Only
545611.901 AR-G2 & AR2000 Smart Swap Concentric Cylinder Peltier Jacket 4,920NOTE: Does not include cup and rotor
32
708.01477 Advanced Fluids Add-on Package for Sealed Bath (Version 2); 6,010Includes: Mixed Metal, 25 mm Titanium Upper & Stainless Lower ParallelPlate Set, Titanium Upper 25 mm 0.04 rad Cone 17 mm Couette TestingPackage
708.01444 ARES Melt Sample Preparation Kit; 3,050Includes: 8 mm, 25 mm punch & die set (to 3 mm thick) Aluminum scraping tool for trimming sample Brass brush for cleaning platesPrecision knife for sample trimming
ARES Air and Calibration Accessories
700.02657.2 Air Dryer 2,580
613.06404 Replacement F73C Green Coalescing Filter Element for Air Dryer 110
613.06406 Replacement F73G 5 micron Filter Element for Air Dryer 10
595120.601 Rheology Advantage Upgrade from Rheology Solutions 1,740
35
545009.901 AR1000/AR550 Concentric Cylinder Double Gap System 5,960Rotor Inner rad = 20.38 mm, RotorOuter rad = 21.96 mm, Rotor Height = 59.5 mm, Cup Inner rad =20 mm, Volume = 6.48 ml
Circulators (Computer Controlled)
500020.901 Computer Controlled Circulator, Model FS18 [US] 7,340For use with CSA II & AR1000/AR550 Concentric Cylinders.
575004.901 Computer Controlled Circulator, Model FS18 [UK] 7,090For use with CSA II & AR1000/AR550 Concentric Cylinders.
500027.901 Computer Controlled Circulator, Model F30C [US] 7,140For Temp Control of AR1000/AR550 Concentric Cylinders
ETC Environmental Test Chamber & KitsETC system requires the chamber & one or more Accessory Kit. The flow meter kit, part# 543311.901, is required if cooling accessory is not specified.
AR-G2 ETC
543401.901 AR-G2 Environmental Test Chamber 10,200
AR-G2 Peltier Concentric Cylinder Temperature SystemsNOTE: AR-G2 Concentric Cylinder Systems include Peltier Jacket and cup and rotor for measurements.
546001.901 AR-G2 Peltier Concentric Cylinder Conical DIN System 9,380Rotor rad = 14 mm, Rotor Height = 42 mm, Cup rad =15mm, Sample Volume = 19.6 ml
546002.901 AR-G2 Peltier Concentric Cylinder Recessed End Bob System 9,380Rotor rad = 14 mm, Rotor Height = 42 mm, Cup rad =15mm, Sample Volume = 6.65 ml
546004.901 AR-G2 Peltier Concentric Cylinder Vaned Rotor System 9,380Rotor rad = 14 mm, Rotor Height = 42 mm, Cup rad =15mm, Sample Volume = 28.72 ml
546003.901 AR-G2 Peltier Concentric Cylinder Double Gap System 9,380Rotor Inner rad = 20.38 mm, RotorOuter rad = 21.96 mm, Rotor Height = 59.5 mm, Cup Inner rad =20 mm, Sample Volume = 6.48 ml
546006.901 AR-G2 Peltier Concentric Cylinder Torsion Submersion System 10,200
AR2000 Peltier Concentric Cylinder Temperature SystemsNOTE: AR2000 Concentric Cylinder Systems include Peltier Jacket and cup and rotor for measurements.
545601.901 AR2000 Peltier Concentric Cylinder Conical DIN System 9,100Rotor rad = 14 mm, Rotor Height = 42 mm, Cup rad =15mm, Volume = 19.6 ml
545602.901 AR2000 Peltier Concentric Cylinder Recessed End Bob System 9,100Rotor rad = 14 mm, Rotor Height = 42 mm, Cup rad =15mm, Volume = 6.65 ml
545604.901 AR2000 Peltier Concentric Cylinder Vaned Rotor System 9,100Rotor rad = 14 mm, Rotor Height = 42 mm, Cup rad =15mm, Volume = 28.72 ml
545603.901 AR2000 Peltier Concentric Cylinder Double Gap System 9,100Rotor Inner rad = 20.38 mm, Rotor Outer rad = 21.96 mm, Rotor Height = 59.5 mm, Cup Inner rad =20 mm, Sample Volume = 6.48 ml
545606.901 AR2000 Peltier Concentric Cylinder Torsion Submersion System 1,020
AR1000/AR550 Concentric Cylinder Temperature Systems, Circulator Temp Control
545002.901 AR1000/AR550 Concentric Cylinder Fluid Jacket 2,400NOTE: AR1000/AR550 Concentric Cylinder Systems include Fluid Jacket and cup & rotorfor measurements. Requires Computer controlled circulator for temperature control,part#500027.901 or part#575008.901
545006.901 AR1000/AR550 Concentric Cylinder Conical DIN System 5,960Rotor rad = 14 mm, Rotor Height = 42 mm, Cup rad =15mm, Volume = 19.6 ml
545007.901 AR1000/AR550 Concentric Cylinder Recessed End Bob System 5,960Rotor rad = 14 mm, Rotor Height = 42 mm, Cup rad =15mm, Volume = 6.65 ml
545008.901 AR1000/AR550 Concentric Cylinder Vaned Rotor System 5,960Rotor rad = 14 mm, Rotor Height = 42 mm, Cup rad =15mm, Volume = 28.72 ml
37
545027.001 Stainless Steel, Recessed End Rotor, rad = 14 mm (For AR2000/1000/550 ) 2,120
545025.001 Stainless Steel, Vaned Rotor, rad = 14 mm (For AR2000/1000/550) 1,740
545028.001 AR2000/1000/550 Wide Gap Vaned Rotor with Heat Break 2,080
545031.001 HA Aluminum Double Gap Rotor, 1,320Inner rad = 20.38 mm, Outer Rad = 21.96 (For AR2000/1000/550)
545035.001 Stainless Steel, Double Gap Rotor, 1,370Inner rad = 20.38 mm, Outer Rad = 21.96 (For AR2000/1000/550)
AR-G2 & AR2000 Peltier Concentric Cylinder Cups
545622.001 AR-G2 & AR2000 HA AL Std. Concentric Cylinder Cup, rad = 30 mm 1,770
545630.001 AR-G2 & AR2000 SST Std. Concentric Cylinder Cup, rad = 30 mm 1,800
545612.901 AR-G2 & AR2000 HA AL Double Gap Concentric Cylinder Cup, 1,970Inner rad = 20 mm
545613.901 AR-G2 & AR2000 SST Double Gap Concentric Cylinder Cup, 2,120Inner rad = 20 mm
545626.001 AR-G2 & AR2000 Split cover for Concentric Cylinders 1,330
545615.901 Peltier Concentric Cylinder 44 mm Dia. Cup 1,300
545642.001 Peltier Concentric Cyl. SST Blank Plug for Double Gap Cup 795
545610.901 AR-G2 & AR2000 SST Grooved Concentric Cylinder Cup 3,950
Stainless Steel Peltier Plate Geometries with Composite Heat BreakNote: Upper Plates for Use with lower Peltier Plate
512080.902 Stainless Steel, Composite HB: 8 mm, NST 1,420
512200.902 Stainless Steel, Composite HB: 20 mm, NST 1,420
512200.901 Stainless Steel, Composite HB: 20 mm 1,420
512250.902 Stainless Steel, Composite HB: 25 mm, NST 1,420
512400.901 Stainless Steel, Composite HB: 40 mm 1,480
512600.901 Stainless Steel, Composite HB: 60 mm 1,530
Note: Following Smart Swap geometries for use with AR-G2 only.
512080.906 AR-G2, Stainless Steel, Composite HB: 8 mm, NST 1,630
512200.906 AR-G2, Stainless Steel, Composite HB: 20 mm, NST 1,630
512200.905 AR-G2, Stainless Steel, Composite HB: 20 mm 1,710
512250.906 AR-G2, Stainless Steel, Composite HB: 25 mm, NST 1,630
512400.905 AR-G2, Stainless Steel, Composite HB: 40 mm 1,890
512600.905 AR-G2, Stainless Steel, Composite HB: 60 mm 1,890
Titanium Peltier Plate Geometries with Solvent TrapNote: Upper Plates for Use with lower Peltier Plate
520400.901 Titanium, 40 mm Plate 2,400
520600.901 Titanium, 60 mm Plate 2,550
Note: Following Smart Swap geometries for use with AR-G2 only.
520600.905 AR-G2 Smart Swap, Titanium, 60 mm Plate 2,100Note: Geometry has stainless steel shaft
520604.905 AR-G2 Smart Swap, Titanium, 60 mm, 1 Deg Cone 2,150Note: Geometry has stainless steel shaft
520606.905 AR-G2 Smart Swap, Titanium, 60 mm, 2 Deg Cone, ST 2,150Note: Geometry has stainless steel shaft
Acrylic Peltier Cone Geometries with NO Solvent Trap (NST)Note: Upper Cones for Use with lower Peltier Plate
516204.902 Acrylic, 20 mm, 1 degree Cone, NST 685
516206.902 Acrylic, 20 mm, 2 degree Cone, NST 685
516207.902 Acrylic, 20 mm, 4 degree Cone, NST 685
43
543330.001 SST, 25 mm Single Piece Upper AR2000 ETC Plate 685(Full Shaft, use with 527250.904)
543331.001 SST, 40 mm Single Piece Upper AR2000 ETC Plate 710(Full Shaft, use with 527400.905 )
Stainless Steel Stepped (lower) and Non-Stepped (upper) Screw-in ETC PlatesNote: For Use with Upper ETC Shaft (AR2000 Part#543112.901, AR1000/550 Part# 543319.901) or ETM upper Shaft
527080.904 SST, 8 mm Stepped Lower ETC Plate (use with 527080.903) 120
527250.903 SST, 25 mm Non-Stepped Upper ETC Plate (use with 527250.904) 120
527250.904 SST, 25 mm Stepped Lower ETC Plate (use with 527250.903) 120
527400.903 SST, 40 mm ETC Plate, Use for upper and lower (2 required) 120
527250.905 SST, Cross Hatched, 25 mm Non-Stepped Upper ETC Plate 275(use with 527250.906)
527250.906 SST, Cross Hatched, 25 mm Stepped Lower ETC Plate (use with 527250.905) 275
527400.905 SST, Cross Hatched 40 mm ETC Plate, Use for upper and lower (2 required) 275
Aluminum Steped Upper Cone Geometry for ETC and ETMNote: For Use with Upper ETC Shaft (AR2000 Part#543112.901, AR1000/550 Part# 543319.901. For correct operationcones require a matched plate [eg 523406.903 4cm2° cone requires 523400.903 4cm plate]
523206.904 AL, 20 mm, 2 deg Cone for ETC & ETM 145
523207.904 AL, 20 mm, 4 deg Cone for ETC & ETM 145
523406.903 AL, 40 mm, 2 deg Cone for ETC & ETM 145
523407.903 AL, 40 mm, 4 deg Cone for ETC & ETM 145
523408.901 AL, 40 mm, 5.6 deg Cone for ETC & ETM 180
Aluminum Steped Plates Cone Geometry for ETM (Compatible with ETC)Note: ETM Stepped plates are compatible with ETC. However, they are NOT annodized and only are available in stepped version.
523200.904 AL, 20 mm ETM Plate, Stepped (compatible with ETC) 85
523250.904 AL, 25 mm ETM Plate, Stepped (compatible with ETC) 100
523400.903 AL, 40 mm ETM Plate, Stepped (compatible with ETC) 75
Aluminum ETC Disposable PlatesNote: For Use with Upper ETC Shaft (AR2000 Part#543, AR1000/550 Part# 543) or ETM upper Shaft
523250.927 Aluminum 25 mm ETC Disposable Plates, Package of 100 790
523400.927 Aluminum 40 mm ETC Disposable Plates, Package of 100 1,020
523250.928 Aluminum 25 mm ETC Disposable Plates with Drip Chanel, Package of 100 1,100
ETC Accessories
543097.911 ETC Melt Rings for 25 mm Lower Stepped ETC Plate, Package of 50 370
42
513207.905 AR-G2, HA Aluminum, 20 mm, 4 deg Cone 1,580
513404.905 AR-G2, HA Aluminum, 40 mm, 1 deg Cone 1,640
513406.905 AR-G2, HA Aluminum, 40 mm, 2 deg Cone 1,640
513407.905 AR-G2, HA Aluminum, 40 mm, 4 deg Cone 1,640
513603.905 AR-G2, HA Aluminum, 60 mm, 0.5 deg Cone 1,650
513604.905 AR-G2, HA Aluminum, 60 mm, 1 deg Cone 1,730
513606.905 AR-G2, HA Aluminum, 60 mm, 2 deg Cone 1,730
513607.905 AR-G2, HA Aluminum, 60 mm, 4 deg Cone 1,730
Hard Annodized Aluminum (HA AL) Peltier Plate Geometries with Solvent TrapNote: Upper Plate for Use with lower Peltier Plate
513200.901 HA AL, 20 mm Plate 1,420
513400.901 HA AL, 40 mm Plate 1,480
513600.901 HA AL, 60 mm Plate 1,510
Note: Following Smart Swap geometries for use with AR-G2 only.
513200.905 AR-G2, HA Aluminum, 20 mm Plate 1,580
513400.905 AR-G2, HA Aluminum, 40 mm Plate 1,590
513600.905 AR-G2, HA Aluminum, 60 mm Plate 1,640
Solvent Trap, Purge Gas, and Thermal Covers for Peltier Plate and Concentric Cylinder
529607.901 Hard Annodized Split Solvent Trap Cover for Solvent Trap Geometries 1,130
529609.901 Peltier Plate Purge Gas Cover 1,370
529608.901 Purge Gas Location Ring for use with Purge Gas Cover 1,180
529750.901 25 mm Plate Insulating Thermal Cover for Peltier Plate 2,800
545609.901 Peltier Concentric Cylinder Solvent Trap. 900Note: Not for use with Double Wall Concentric Cylinder system
AR-G2/AR2000/AR1000/AR5500 ETC & ETM Screw-In Cone and Plate Geometries
Hard Annodized Aluminum Stepped (lower) and Non-Stepped (upper) ETC PlatesNote: For Use with Upper ETC Shaft (AR2000 Part#543112.901, AR1000/550 Part# 543319.901 and/or Lower ETC Fixture
526080.904 HA AL, 8 mm Stepped Lower ETC Plate (2 required) 65
526250.903 HA AL, 25 mm Non-Stepped Upper ETC Plate (use with 526250.904) 50
526250.904 HA AL, 25 mm Stepped Lower ETC Plate (use with 526250.903) 85
526400.903 HA AL, 40 mm ETC Plate, Use for upper and lower (2 required) 65
AR2000 Stainless Steel Upper ETC Plates, Single Piece Geometries
527080.903 SST, 8 mm Single Piece Upper AR2000 ETC Plate 895(Full Shaft, use with 527080.904)
45
Quartz Geometries
524400.902 Quartz, 40 mm Parallel Plate, AR2000, AR1000, & AR550 Only 1,610
Ambient Disposable Plate System Note: Clip-on System for AR Series Peltier Plate, Temperature is NOT controlled by the Peltier Plate
585037.901 CSA & CSA II Replacement Solenoid Valve 475
554007.901 Asphalt Sample Molds, 1 Pair 90
Peltier, UHP, Dry Asphalt Sys Replacement Parts
575001.901 Temperature Controlled Peltier Water Bath [UK] 1,700
250001.001 Submersible Pump for Peltier Temp Systems [US] (Temporary Use Only) 265
575002.901 Submersible Pump for Peltier Temp Systems [UK] (Temporary Use Only) 250
44
Upper Heated Plate, CSA, & Dry Asphalt System Screw-in PlatesNOTES: Screw-in Parallel Plate for use with following Systems: 1)CSA/CSA II: Lower Plate only, 2) AR-G2 & AR2000UHP with Std. Peltier Plate: Upper plate Only and 3)AR-G2 & AR2000 Dry Asphalt System: For Upper and lower use (Two of these parts are required to replace both upper and lower).
554001.901 Stainless Steel, 8 mm Screw-in Parallel Plates for CSA, UHP, & Dry Asphalt 515
554008.901 Stainless Steel, 12 mm Screw-in Parallel Plates for CSA, UHP, & Dry Asphalt 515
554002.901 Stainless Steel, 25 mm Screw-in Parallel Plates for CSA, UHP, & Dry Asphalt 515
554019.902 HA Aluminum, 8 mm Screw-in Parallel Plates for CSA, UHP, & Dry Asphalt 500
554020.902 HA Aluminum, 25 mm Screw-in Parallel Plates for CSA, UHP, & Dry Asphalt 500
545712.901 AR-G2, Replacement Rotor for Starch Pasting Cell 1,520
545713.901 AR-G2, HA AL Conical Rotor For Starch Pasting Cell 1,890
545701.901 AR2000 Starch Pasting Cell 8,000
545723.001 Replacement cup for Starch Pasting Cell 295
545751.001 Replacement Rotor for Starch Pasting Cell, AR2000 Only 1,220
545761.001 HA AL Conical Rotor For Starch Pasting Cell, AR2000 Only 1,680
AR2000 Smart Swap Interfacial Rheology Systems & Accessories
545902.901 Dynamic Interfacial Rheology System for AR-G2 3,900
545901.901 Interfacial Viscosity Bicone System for AR2000 3,000Note:Includes 45 mm dia Teflon cup, 34 mm diameter and 10° angle stainless steelbicone geometry, and cover.
545922.001 45 mm Diameter Teflon Interfacial Cup for AR2000 and AR-G2 625
545931.001 34 mm 10° Stainless Steel Bicone Geometry 835
575101.901 High Viscosity Standard Oil, Nominal Viscosity 17 Pa.s (N4000) [UK] 115
Rheology Text Books
575105.901 A Handbook of Elementary Rheology, Howard A. Barnes 70
575103.901 Introduction to Rheology, H.A. Barnes, J.F. Hutton and K. Walters 105
General Information
Minimum order requirements: $100. All prices f.o.b. shipping point. Prices and specifications arethose in effect at the time of printing and are subject to change without notice. International pricesare additional in most countries. All orders are subject to final acceptance.N