Top Banner
1 Innovative Offerings for Membrane and Thermal Desalination Plants Asif Sheikh Industry Development Manager Innovations Marketing Desalination Nalco Gulf Ltd, Dubai, UAE
24

NALCO1

Feb 02, 2016

Download

Documents

cvolkan1

Innovative Offerings for
Membrane and Thermal
Desalination Plants
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: NALCO1

1

Innovative Offerings for Membrane and Thermal

Desalination Plants

Asif Sheikh

Industry Development Manager

Innovations Marketing – Desalination

Nalco Gulf Ltd, Dubai, UAE

Page 2: NALCO1

2

www.nalco.com

Page 3: NALCO1

3

Our Global Business Model

Page 4: NALCO1

4

Nalco a Strategic Resource - Creating and Maintaining Value

Page 5: NALCO1

5

Existing Offerings from Chemical Suppliers

Services

Chemicals

Programs

• Antiscalants approved for potable? • Antiscalant selection and dose ? • Global references ?

• Tried & Tested ? • Tailored ? • Case Studies ? • Value Adding / Differentiating ?

• Plant Survey / Audit conducted ? • Performance Reporting in place ? • Membrane Autopsy Services ? • Local on-site Service capabilities / support ? • Troubleshooting and Consultative Expertise ?

Are suppliers Adding Value ? - Asset protection - Maintaining production

and quality - Reducing O&M costs

Page 6: NALCO1

6

Innovative Offerings from Nalco

Antiscalant Chemistries

Equipment

Communication

Platform

Page 7: NALCO1

7

Innovative ANTISCALANT CHEMISTRIES

RO Membrane Desalination ANTISCALANTS

• Phosphorus-Free Scale Inhibitor (PC-1611T)

- Replacement for typical Phosphonate antiscalants

• Calcium Phosphate specific Scale Inhibitor (PC-1521T)

- Reduced need for depressing pH in water reuse applications

MSF and MED Thermal Desalination ANTISCALANT

• High Top-Brine-Temp & High Concentration Ratio Scale Inhibitor (PC-2040T)

T is the TRACER Fluoresence in all Nalco Desalination Antiscalants

that allows for the concentration to be measured instantaneously

Page 8: NALCO1

8 8

Innovative EQUIPMENT

Thermal (3DTfTD) Membrane (3DTfM)

Nalco Global Gateway

Fluorometer

3DT Controller

3DT Technology: Detect - Determine - Deliver

Page 9: NALCO1

9

Innovative COMMUNICATION PLATFORM

enVision: The Power of Information on Demand

Our new web-based data management platform and

system management dashboard to help optimize and

continuously improve your systems’ performance.

Page 10: NALCO1

10

3DTfM

3DT for Membranes

Page 11: NALCO1

11

Page 12: NALCO1

12

Traced RO Antiscalant Dosage Control with 3DTfM

Page 13: NALCO1

13

Normalized Data Trends with Nalco 360

Permeate

Feed Water

Data Download

Trending & Analysis

Page 14: NALCO1

14

Enhanced Normalization Reports

Page 15: NALCO1

15

3DTfTD

3DT for Thermal Desalination

Page 16: NALCO1

16

Nalco’s Innovation Antiscalant for Thermal Desalination Plants

• Most MSF plants operate between a TBT of 95 to 115 degC

• Industry standard antiscalant dosing on MSF plants is 1.5 - 2.5 ppm

• 3-phase pilot MSF trial with Nalco’s Innovation Antiscalant conducted at SWDRI in Saudi Arabia

• Successfully tested at various operating conditions - SWDRI Certificates

• Most aggressive condition was successfully tested at a TBT of 119 degC, CR of 1.9 and down to a dosage of 0.8 ppm

• Significant opportunities for the industry;

- Reduce TCO using Nalco’s 3DTfTD unit to safely optimise PC-2040T antiscalant dose by UP TO 50%

- Increase production at higher TBT operation

16

Page 17: NALCO1

17

3DT for Thermal (3DTfTD) applicable for both MSF & MED Plants

17

Sampling BEFORE

PC-2040T dosing

Sampling AFTER

PC-2040T dosing

Sampling in Distillate

(OPTIONAL)

OR

Make-up Line

(IMPORTANT)

Sampling in

Brine Blowdown

line (IMPORTANT)

Page 18: NALCO1

18 18

EXAMPLE SCHEMATIC for a MSF plant showing PC-2040T Dosing and Fluorometer sampling points

Distillate

Antiscalant Dosing Provision B

based on SW Make-Up Flow

SW Make-UP

Blowdown Fluorometer

Untreated Brine Recycle Fluorometer

Brine Recycle

Treated Brine Recycle Fluorometer

Blowdown

SW Make-Up Fluorometer

Heat Recovery section Heat Rejection section

Stage19

Stage16

Stage1

Page 19: NALCO1

19 19

On-line MONITORING of PC-2040T on MSF plant#1 - REAL CASE

Page 20: NALCO1

20 20

On-line CONTROL of PC-2040T on MSF plant#2 - REAL CASE

Page 21: NALCO1

21

On-line CONTROL of PC-2040T on an MED plant - REAL CASE

BEFORE AFTER

21

Page 22: NALCO1

22

• On-line monitoring of temperatures and turbidity using fluorometer sample points

• On-line monitoring of Brine Blowdown residual concentration of PC-2040T allows for continual verification of Concentration Ratio

• On-line changes in Seawater Turbidity monitoring enables 3DTfTD unit to adjust PC-2040T dose rate

• Connecting the Ball Cleaning system status (ON/OFF) to the 3DTfTD unit enables adjustment of PC-2040T dose rate

• Automatically web-generated reports on a daily basis consisting of various performance and parameter trends

Additional Features of the 3DTfTD unit

22

Page 23: NALCO1

23

Performance Management with Chemistry + Automation

Nalco has built this innovation on the

3D TRASAR technology platform

This combines novel sensor technology,

advanced treatment programs, modern

communication and expert consultancy

Page 24: NALCO1

24 24

enVision: The Power of Information on Demand