www.kmi.co.id PT KMI Wire and Cable Tbk reserves the right to change the data content without prior notification Conductor Inductance (mH/km) Current - Carrying Capacity at 30° C * Short circuit current at 1 sec Nom. Cross Sect. (mm²) DC Resistance at 20°C Max. (Ω/km) AC Resistance at 90°C Max. (Ω/km) in air Max. (A) in ground Max. (A) Conductor Max. (kA) Screen Max. (kA) N2XSEFGbY 3 x (25-300) mm² 3.6/6 kV N2XSEFGbY 3 x (25-300) mm² 3.6/6 kV Cu / XLPE / CTS / PVC / SFWA / PVC Application : For installation in the ground, indoors, cable trunking and outdoors if increased mechanical protection is required or where high-pulling stresses may occur during installation or operation. Special Features on Request • Fire Resistance • Oil Resistance • UV Resistance • Flame Retardant Cat. A, B, C • Flame Retardant Non Category • Anti Termite • Anti Rodent • Low Smoke Zero Halogen Note : Conductor Shape 25 - 300 sqmm supplied in compacted circular stranded (cm) conductor shape Standard Packing 25 - 50 sqmm supplied in wooden drum @ 1000 m 70 - 300 sqmm will be suplied in wooden drum on available length Length Tolerance per drum ± 2% Nom. Cross Section Area Overall Diameter Cable Weight approx. approx. mm² mm kg/km Construction Data 25 38.5 2,603 35 41.5 3,074 50 44.5 3,641 70 48.5 4,536 95 52.0 5,542 120 56.0 6,516 150 59.5 7,593 185 63.0 8,940 240 69.0 11,074 300 75.5 13,395 Electrical Data 25 0.727 0.927 0.342 152 147 3.58 1.03 35 0.524 0.668 0.325 185 175 5.01 1.03 50 0.387 0.494 0.313 219 205 7.15 1.03 70 0.268 0.342 0.296 273 251 10.01 1.03 95 0.193 0.247 0.285 330 299 13.59 1.03 120 0.153 0.196 0.276 379 339 17.16 1.03 150 0.124 0.160 0.268 430 379 21.45 1.03 185 0.0991 0.128 0.262 490 427 26.46 1.03 240 0.0754 0.099 0.255 573 490 34.32 1.37 300 0.0601 0.080 0.252 649 547 42.90 1.37 (Copper Conductor, XLPE Insulated, Copper Tape Screen, Galvanized Steel Flat Wire Armor, PVC Sheathed) Standard Specification : IEC 60502-2 Galvanized Steel Tape Galvanized Steel Flat Wire Armor 16933-01 Rev. 2.0 / 2009
5
Embed
N2XSEFGbY 3 x (25-300) mm² 3.6/6 kVN2XSEFGbY 3 x …files.kabelmetal-indonesia.com/contents/IEC/MV/CPConductor/N2... PT KMI Wire and Cable Tbk reserves the right to change the data
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
www.kmi.co.idPT KMI Wire and Cable Tbk reserves the right to change the data content without prior notification
www.kmi.co.idPT KMI Wire and Cable Tbk reserves the right to change the data content without prior notification
Application :For installation in the ground, indoors, cable trunking and outdoors if increased mechanical protection is required or where high-pulling stresses may occur during installation or operation.
Special Features on Request• FireResistance• OilResistance• UVResistance• FlameRetardantCat.A,B,C• FlameRetardantNonCategory• AntiTermite• AntiRodent• LowSmokeZeroHalogen
Standard Packing25 - 50 sqmm supplied in wooden drum @ 1000 m70 - 300 sqmm will be suplied in wooden drum on available lengthLength Tolerance per drum ± 2%
Application :For installation in the ground, indoors, cable trunking and outdoors if increased mechanical protection is required or where high-pulling stresses may occur during installation or operation.
Special Features on Request• FireResistance• OilResistance• UVResistance• FlameRetardantCat.A,B,C• FlameRetardantNonCategory• AntiTermite• AntiRodent• LowSmokeZeroHalogen
Standard Packing25 - 35 sqmm supplied in wooden drum @ 1000 m50 - 300 sqmm will be suplied in wooden drum on available lengthLength Tolerance per drum ± 2%
Application :For installation in the ground, indoors, cable trunking and outdoors if increased mechanical protection is required or where high-pulling stresses may occur during installation or operation.
Special Features on Request• OilResistance• UVResistance• FlameRetardantCat.A,B,C• FlameRetardantNonCategory• AntiTermite• AntiRodent• LowSmokeZeroHalogen
Application :For installation in the ground, indoors, cable trunking and outdoors if increased mechanical protection is required or where high-pulling stresses may occur during installation or operation.
Special Features on Request• OilResistance• UVResistance• FlameRetardantCat.A,B,C• FlameRetardantNonCategory• AntiTermite• AntiRodent• LowSmokeZeroHalogen
Application :For installation in the ground, indoors, cable trunking and outdoors if increased mechanical protection is required or where high-pulling stresses may occur during installation or operation.