15 16 17 18 19 20 21 22 23 24 25 1 2 3 4 5 13 12 10 6 8 9 11 14 7 4,106 3,000 8,883 5,800 7,100 5,932 4,150 1,000 250 1,700 11,584 600 900 300 3600 900 900 900 450 2700 450 900 900 900 3600 1800 26.93 m 2 fenced bin store with wash down facilities with drain (10m 2 ) 2 x 3000L water tanks rendered blockwork timber battens over blockwork acoustic perspex sign with max. protrusion of 100mm 32.99 90°0'0" 20.72 32.99 90°0'0" 20.72 90°0'0" 90°0'0" 16.09 130°57'56" 24.76 128°0'3" 25.35 79°57'29" 29.45 111°4'32" 27.59 25.87 26.05 26.01 25.85 25.87 25.89 26.01 26.03 25.95 25.98 25.95 25.97 26.05 25.79 25.88 26.07 26.07 26.08 25.90 25.99 25.78 25.83 25.78 25.82 25.85 25.86 25.85 25.62 25.68 25.77 25.78 25.83 25.82 25.81 25.86 28.00 26.17 26.08 25.95 25.64 25.70 25.82 25.89 26.01 26.07 26.11 26.17 25.83 25.68 26.28 26.01 25.97 25.97 25.93 26.10 25.96 26.09 26.14 26.07 26.11 26.11 26.04 25.97 25.99 25.9 25. 74 25.75 25.84 25.94 25.82 25.65 25.76 25.82 25.74 26.38 25.98 25.90 26.11 26.14 25.96 26.00 25.89 25.86 25.85 25.91 26.40 26.16 26.16 26.42 26.41 26.57 26.56 26.59 26.57 26.56 26.46 26.51 26.44 26.50 26.47 26.50 26.52 26.51 26.44 26.36 26.43 26.33 26.19 26.08 26.03 25 .94 26.04 25.99 25.98 26.00 26.07 26.46 26.33 26.26 26.25 26.36 26.47 26.50 26.50 26.49 26.24 26.31 26.31 26.32 25.93 26.02 25.79 25.77 25.84 25.73 25.84 25.55 25.50 25.66 25.69 25.79 25.93 25.88 26.14 26.13 26.03 25.91 25.80 25.86 25.91 25.94 25.94 25.35 25.22 25.08 25.04 24.93 24.99 24.86 24.92 24.88 24.80 25.02 24.97 24.95 24.98 25.21 25.10 25.51 25.54 25.47 25.86 25.87 25.81 25.80 25.80 25.86 25.40 25.30 25.26 25.25 25.36 24.75 24.76 24.74 24.75 24.69 24.74 24.74 24.77 24.74 24.77 24.77 24.76 25.57 25.20 24.89 24.73 24.75 24.70 24.73 23.59 24.11 24.54 24.39 24.55 24.58 24.66 24.67 24.76 24.51 24.48 24.56 24.29 23.50 24.10 23.77 24.70 24.63 24.66 24.73 24.72 24.73 24.59 24.50 24.38 24.40 24.23 24.24 24.21 24.14 24.15 24.19 24.54 24.47 24.43 24.28 24.31 23.85 24.27 24.14 23.74 23.79 23.70 23.66 23.68 23.81 23.73 23.88 23.97 23.97 24.00 23.95 24.83 24.90 24.88 24.84 24.84 24.81 24.96 25.91 25.53 25.54 24.86 25.50 24.89 26.21 24.97 25.07 25.08 25.46 25.41 25.39 26.54 25.34 Power Pole Street Sign Sewer I.O. Power Pole Ref Nail At Base Of Kerb A.H.D. level 25.30m (Established from S.S.M. MULLALOO 32A using data supplied by the Geodetic Section of Landgate) Brick Paved Brick Paved Brick Paved Concrete Path Concrete Path Concrete Path Concrete Crossover Concrete Crossover Concrete Path Drainage M/H (Top Lid 23.77) (Bottom Pit 22.55) Verge Tree Ø 0.03m Ht 2.0m Pipe Ø 0.4m (Bottom 22.70) Pipe Ø 0.4m (Bottom 22.73) 24.28 24.67 24.81 TF [ Grass Hydrant (Metal) H Closest Wire To Boundary Bitumen Forrest Road Semi-Mount Semi-Mount Concrete Ramp Nil Grass Grass Grass Grass Grass Grass Carport UMR Galv. Pergola #5 Brick & Tile On Slab Approx House F/L @ Front Door 23.67 Concrete Driveway L/stone Ret. Wall Timber Ret. Wall (top&gl) Concrete Ramp Nil Nil Sewer M/H (24.87) Pipe Ø 0.4m (Bottom 23.23) Gully Pit (Top Lid 24.79) (Bottom Pit 23.04) Mountable Mountable Mountable Mountable Flush 25.45 Biutmen Biutmen 25.43 Drainage M/H (Top Lid 25.10) (Bottom Pit 22.92) Pipe Ø 0.4m (Bottom 23.70) Pipe Ø 0.4m (Bottom 23.72) 25.50 Median Strip Median Strip Semi-Mount Semi -Mount Semi -Mount Street Sign stay anchor Metal Bar Light & Power Pole (H/T) Light & Power Pole (H/T) Closest Wire To Boundary High Tension Power Wire Closest Wire To Boundary Stay Wire Stay Wire Concrete Path Concrete Path stay anchor Stay Wire Grass & Bush Bush 25.77 25.89 27.74 TF [ ] 26.26 Bush Bush PEG FND PEG GONE PEG GONE PEG GONE PEG GONE PEG GONE 26.05 TF TR 26.18 TR TF TR 26.07 L/stone Ret. Wall 27.98 TF Brick & Tile On Slab -Clear Brick & Tile On Slab -Clear Tree Ø 0.7m Ht 6.0m Tree Ø 0.3m Ht 5.0m Tree Ø 0.7m Ht 15.0m Tree Ø 0.3m Ht 5.0m Tree Ø 0.4m Ht 5.0m Tree Ø 0.5m Ht 8.0m Verge Tree Ø 0.10m Ht 3.0m Verge Tree Ø 0.20m Ht 3.0m Verge Tree Ø 0.20m Ht 3.0m Tree Ø 0.5m Ht 6.0m Tree Ø 0.6m Ht 6.0m Tree Ø 0.2m Ht 8.0m Tree Ø 0.7m Ht 8.0m Tree Ø 0.2m Ht 3.0m Verge Tree Ø 0.25m Ht 3.0m Verge Tree Ø 0.20m Ht 3.0m Tree Ø 0.7m Ht 15.0m Tree Ø 0.8m Ht 10.0m Verge Tree Ø 0.30m Ht 5.0m Verge Tree Ø 0.40m Ht 5.0m Verge Tree Ø 0.20m Ht 2.0m Verge Tree Ø 0.30m Ht 5.0m Verge Tree Ø 0.30m Ht 5.0m Verge Tree Ø 0.60m Ht 5.0m Verge Tree Ø 0.20m Ht 5.0m Sewer Junction Inv: 22.4 Depth: 2.6 NOTE: UP BEWARE: Deep sewer junction. Check With Water Corp BUILDER and PLUMBER check GRADE. NOTE: Approx. Sewer Clearance Line (This line is NOT an easement) Setbacks MUST be confirmed by Water Corp. before any design work is undertaken. This line is NOT definitive. Sewer Junction Inv: 22.7 Depth: 2.8 NOTE: UP BEWARE: Deep sewer junction. Check With Water Corp BUILDER and PLUMBER check GRADE. Sewer Junction Inv: 21.5 Depth: 2.8 NOTE: UP BEWARE: Deep sewer junction. Check With Water Corp BUILDER and PLUMBER check GRADE. NOTE: Approx. Sewer Clearance Line (This line is NOT an easement) Setbacks MUST be confirmed by Water Corp. before any design work is undertaken. This line is NOT definitive. R. O. W Marmion Avenue Bitumen 24 . 5 24.5 25.0 25 .0 25.5 25.5 26.0 26.0 26.5 26.5 26.0 26.0 26.0 26.0 26.0 26.0 26 .0 25.5 25.0 25 .5 Median Strip outdoor play space 2 UNENCUMBERED 307.96sqm outdoor play space 1 UNENCUMBERED 81.81sqm bin store LANDSCAPING DRIVEWAY FOOTPATH BUILDING FOOTPRINT OUTDOOR PLAYSCAPE SITE COVERAGE - 575.04sqm / 35.17% GFA - 688.83sqm / 42.13% HARDSTAND - 639.33sqm / 39.10% LANDSCAPING(excluding playspace) - 174.78sqm / 10.69% 82 PLACES 14 STAFF OUTDOOR SPACE: REQUIRED - 574.00sqm UNENCUMBERED - 629.61sqm CAR PARKING: 2.6x4.9m min - 11 2.6x5.4m min - 5 2.6x5.4m min (tandem) - 8 2.4x4.9m min (DISABLED) - 1 dry court crossover FORREST ROAD carpark staff 5400 x 2600 1 of 13 staff 5400 x 2600 2 of 13 staff 5400 x 2600 3 of 13 staff 5400 x 2600 4 of 13 staff 5400 x 2600 5 of 13 staff 5400 x 2600 6 of 13 staff 5400 x 2600 7 of 13 staff 5400 x 2600 8 of 13 staff 4900 x 2600 9 of 13 staff 4900 x 2600 10 of 13 staff 4900 x 2600 11 of 13 staff 4900 x 2600 12 of 13 staff 4900 x 2600 13 of 13 visitor 5400 x 2600 5 of 11 visitor 5400 x 2600 4 of 11 visitor 5400 x 2600 3 of 11 visitor 5400 x 2600 2 of 11 visitor 5400 x 2600 1 of 11 disabled 5400 x 2400 visitor 4900 x 2600 6 of 11 visitor 4900 x 2600 7 of 11 visitor 4900 x 2600 8 of 11 visitor 4900 x 2600 9 of 11 visitor 4900 x 2600 10 of 11 visitor 4900 x 2600 11 of 11 proposed childcare FFL: 26.150(tbc) bikes ramp SIGN 1.8m ACOUSTIC FENCE 1.5m POOL FENCE (AS PER ACOUSTIC REPORT) N Proposed Site Plan Scale 1:200 Use written dimensions only. Do not scale drawings from plans Building zone is to be cleared of any vegetation and trees to suit - check on site. All survey data taken from DWG/PDF copy by others. Cyber Drafting & Design take no responsibilty of the proposed slab & pad levels due to the possibility of in- accurancy of the discloure plan. Verify all bearing and dimensions on site prior to construction. All missing pegs to be re-instated prior to any construction. Notify head contractor immediately of any descrepencies in setout dimensions. Do not strat construction until all boundaries are confirmed. Ensure all drawings and accompanying details and/or specifcations have been stamped as 'Approved' by the relevant local authorities prior to use. All site drainage to be graded to rubble pits or approved site drainage pits at a min grade of 1:100 (1%) and connected to legal point of discharge in compliance with AS/NZ 3500 &/or NCC BCA vol. 2. parts 3.1.2 & 3.5.2 notes: site: Lot 523 number: 1-3 street: Forrest Road locality: Padbury WA 6025 city: Joondalup plan: 9938 property description area: 1635m² (1051m² / 583m²) PRELIMINARY DRAWINGS - NOT FOR CONSTRUCTION. I/ WE APPROVE THESE DRAWINGS TO BE CORRECT AS PER CONTRACT rev. Coulston Group date description client details: N2 SIGNATURE SIGNATURE drawn: - 2 of 7 DATE DATE Sheet Size PROPOSED SITE PLAN 17085 designed: A2 sheets in set drawing scales checked: fasade type orientation drawing job number wind rating drawing title drawn date: JM RT Dimensions shall not be obtained by scaling. All dimensions are in millimeters unless noted otherwise. Setout dimensions shall be verified on site prior to any work being carried out. Any problems shall be directed to the builder for clarification & correction as shown CLIENT 6/10/2017 JODIE MARK e. [email protected]p. 07 3393 9159 6/1631 WYNNUM ROAD, TINGALPA QLD 4173 PH: (07) 3393 9159 ABN: 25 890 335 667 BSA: 1134977 1-3 Forrest Road Padbury WA 6025 RP: 9938 - local council: Joondalup C 17/08/17 DA Plans D 18/08/17 Fencing Updated F 06/10/17 Updated DA Plans E 21/09/17 Updated DA Plans
8
Embed
N PRELIMINARY DRAWINGS - NOT FOR · PDF filePEG FND PEG GONE PEG GONE PEG GONE PEG GONE PEG GONE 26. 05 TF TR 26. 18 ... Do not scale drawings from ... accurancy of the discloure plan
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
1516
1718
1920
2122
2324
25
12
34
5
1312
106
89
1114 7
4,106
3,00
0
8,88
3
5,800 7,100
5,932
4,150 1,000 250
1,700
11,584
600
900
300
3600 900 900 900 450 2700 450 900 900 900 3600
1800
26.93 m2
fenced bin store withwash down facilities withdrain (10m2)
2 x 3000L water tanks
rendered blockwork timber battens over blockwork acoustic perspex
sign with max. protrusion of 100mm
32.9
9
90 °0 '0 "
20.72
32.9
9
90 °0 '0 "
20.7290
°0'0"
90 °0 '0 "
16.0913
0°57
'56 "
24.76
1 2 8 °0 '3 "
25.3
5
79 °57 '29 "
29.45
111°4'32"
27
.59
2 5 .87
2 6 .0 5
26.01
25.85
25
.87
25
.89
2 6 .01 2 6 .0 3
25
.95
2 5 .9 8
2 5 .95
2 5 .97
2 6 .05
2 5 .79
2 5 .88
26
.07
2 6 .07
2 6 .08
2 5 .9 0
2 5 .99
2 5 .78
25.83
25
.78
2 5 .82
25.85 25.86 25.85
25 .62
2 5 .68
25
.77
25
.78
25.83
25.82
25 .81
2 5 .86
28
.0026
.17
26.08
25
.95
2 5 .64
2 5 .70
2 5 .82
2 5 .89
2 6 .01
26.07
26.11
26
.17
25.83
25.68
26
.28
2 6 .01
2 5 .97
2 5 .97
2 5 .93
26
.10
2 5 .96
2 6 .09
26
.14
2 6 .07
2 6 .11
2 6 .11
2 6 .04
2 5 .97
2 5 .992 5 .9
92 5 .9
9
2 5 .7 4
25
.75
25
.84
25
.94
25
.8225
.65
25
.76
2 5.8
2
2 5 .7 4
2 6 .38
2 5 .98
25
.90
2 6 .11
2 6 .14 2 5 .9
6
2 6 .0 0
2 5 .8 9
25
.86
2 5 .8 525
.91
2 6 .4 0
2 6 .1 6
2 6 .1 6
2 6 .4 2
2 6 .4 12 6 .5 7
2 6 .5 62 6 .5 9
2 6 .5 7
2 6 .5 6
2 6 .4 6 2 6 .5 1
2 6 .4 4
2 6 .50 2 6 .4
7
2 6 .50
2 6 .52
2 6 .51
2 6 .44
2 6 .36
2 6 .4 32 6 .3 3
26
.19
26
.08
26
.03
25
.94
26
.04
2 5 .9 9
2 5 .9 8
2 6 .002 6 .0
7
2 6 .46
2 6 .33
2 6 .26 2 6 .2
5
2 6 .36
2 6 .47
2 6 .50
2 6 .50
2 6 .49
2 6 .2 4
2 6 .3 1
2 6 .31
2 6 .32
2 5 .93
2 6 .0 2
25.79 25.7725.84
25.73
25 .84
2 5 .55
2 5 .502 5 .6
6
2 5 .692 5 .7
92 5 .9
3
2 5 .88
2 6 .14
2 6 .13 2 6 .0
3
2 5 .91
2 5 .8 0
2 5 .8 6
2 5 .91
2 5 .94
2 5 .94
25
.35
25
.22
2 5 .0 8 25.04
24.93
24.99
24.86
24
.92
24.88
24.80
25.02
24.97
24.9524.9825.21
25.10
25.51 25.54
25.47
25
.86
25.87
25.81
25
.80
25.80
25.86 25.40
25.30
25 .26
25
.25
25
.36
2 4 .75
24.762 4 .7 4
2 4 .7 52 4 .6 9
2 4 .7 4
24.7424.77
2 4 .7 4
24
.77
24
.77
24.76
25 .57
2 5 .20
24.89
24
.73
24
.75
24.70
24 .73
23
.59
24.11
24
.54
24
.39
24.55
24 .58
2 4 .66
2 4 .6724.76
24 .51
24
.48
2 4 .56
24
.29
23
.50
24
.10
23
.77
24
.70
24
.63
24.66
24 .73
2 4 .72
24.73
24 .59
2 4 .50
24
.38
24.40
24.23
24 .24
2 4 .21
2 4 .142 4 .15
2 4 .19
2 4 .54 2 4 .4
7
2 4 .43
24.28
24 .31
23.85
24.27
24 .14
2 3 .74
2 3 .79 2 3 .7
0
2 3 .66
2 3 .68
2 3 .8 1
2 3 .73
2 3 .88
2 3 .972 3 .97
2 4 .00
2 3 .95
24.83
24.90
24 .882 4 .8
4
2 4 .84
24.81
24
.96
2 5 .91
25
.53
25
.54
24
.86
25.50
24 .89
26
.21
24
.97
2 5 .07
2 5 .08
2 5 .46
2 5 .41
25.39
26 .54
2 5 .34
PowerPole
Street Sign
Sew
er I.
O.
PowerPole
Ref Nail At Base Of Kerb A.H.D. level 25.30m(Established from S.S.M. MULLALOO 32Ausing data supplied by the Geodetic Sectionof Landgate)
Brick PavedBrick PavedBrick Paved
Concrete PathConcrete Path
Concrete Path
ConcreteCrossover
ConcreteCrossover
Concrete Path
Drainage M/H(Top Lid 23.77)
(Bottom Pit 22.55)
Verge TreeØ 0.03mHt 2.0m
Pipe Ø 0.4m(Bottom 22.70)
Pipe Ø 0.4m(Bottom 22.73)
24.2824.6724.81
TF[
Grass
Hydrant(Metal)H
Closest WireTo Boundary
Bitumen
F o r r e s t R o a dSemi-Mount
Semi-Mount
ConcreteRampNil
Grass
Grass
Grass
Grass
Grass
Grass
CarportUMR
Galv.Pergola
#5Brick & Tile
On Slab
Approx House F/L@ Front Door 23.67
ConcreteDriveway
L/stoneRet. Wall
TimberRet. Wall
(top&gl)
Concrete RampNil Nil
SewerM/H (24.87)
Pipe Ø 0.4m(Bottom 23.23)
Gully Pit(Top Lid 24.79)
(Bottom Pit 23.04)
Mountable
Mou
ntab
le
Mou
ntab
le
Mountable
Flus
h
25.45
Biutmen
Biutmen
25.43
Drainage M/H(Top Lid 25.10)
(Bottom Pit 22.92)
Pipe Ø 0.4m(Bottom 23.70)
Pipe Ø 0.4m(Bottom 23.72)
25.50
Median Strip
Median Strip
Semi-Mount
Semi-M
ount
Sem
i-Mou
nt
Street Sign
stayanchor
MetalBar
Light &PowerPole(H/T)
Light &PowerPole(H/T)
Clo
sest
Wire
To
Boun
dary
Hig
h Te
nsio
n Po
wer
Wire
Closest WireTo Boundary
StayWire
StayWire
Concrete Path
Con
cret
e Pa
th
stayanchorStay
Wire
Grass & Bush
Bush
25.77
2 5 .8 9
27.74TF[ ]
2 6 .2 6
Bush
Bush
PEGFND
PEGGONE
PEGGONE
PEGGONE
PEGGONE
PEGGONE
2 6 .0 5
TF
TR
26
.18
TRTF
TR
2 6 .0 7
L/stoneRet. Wall
27
.98
TF
Brick & TileOn Slab-Clear
Brick & TileOn Slab-Clear
TreeØ 0.7mHt 6.0m
TreeØ 0.3mHt 5.0m
TreeØ 0.7mHt 15.0m
TreeØ 0.3mHt 5.0m
TreeØ 0.4mHt 5.0m
TreeØ 0.5mHt 8.0m
Verge TreeØ 0.10mHt 3.0m
Verge TreeØ 0.20mHt 3.0m
Verge TreeØ 0.20mHt 3.0m
TreeØ 0.5mHt 6.0m
TreeØ 0.6mHt 6.0m
TreeØ 0.2mHt 8.0m
TreeØ 0.7mHt 8.0m
TreeØ 0.2mHt 3.0m
Verge TreeØ 0.25mHt 3.0m
Verge TreeØ 0.20mHt 3.0m
TreeØ 0.7mHt 15.0m
TreeØ 0.8mHt 10.0m
Verge TreeØ 0.30mHt 5.0m
Verge TreeØ 0.40mHt 5.0m
Verge TreeØ 0.20mHt 2.0m
Verge TreeØ 0.30mHt 5.0m
Verge TreeØ 0.30mHt 5.0m
Verge TreeØ 0.60mHt 5.0m
Verge TreeØ 0.20mHt 5.0m
Sewer JunctionInv: 22.4 Depth: 2.6NOTE: UP
BEWARE:Deep sewer junction.Check With Water CorpBUILDER and PLUMBERcheck GRADE.
NOTE:Approx. Sewer Clearance Line(This line is NOT an easement)
Setbacks MUST be confirmedby Water Corp. before anydesign work is undertaken.This line is NOT definitive.
Sewer JunctionInv: 22.7 Depth: 2.8NOTE: UP
BEWARE:Deep sewer junction.Check With Water CorpBUILDER and PLUMBERcheck GRADE.
Sewer JunctionInv: 21.5 Depth: 2.8NOTE: UP
BEWARE:Deep sewer junction.Check With Water CorpBUILDER and PLUMBERcheck GRADE.
NOTE:Approx. Sewer Clearance Line(This line is NOT an easement)Setbacks MUST be confirmedby Water Corp. before anydesign work is undertaken.This line is NOT definitive.
CAR PARKING:2.6x4.9m min - 112.6x5.4m min - 52.6x5.4m min (tandem) - 82.4x4.9m min (DISABLED) - 1
drycourt
crossover
FORREST ROAD
carpark
staff5400 x 2600
1 of 13
staff5400 x 2600
2 of 13
staff5400 x 2600
3 of 13
staff5400 x 2600
4 of 13
staff5400 x 2600
5 of 13
staff5400 x 2600
6 of 13
staff5400 x 2600
7 of 13
staff5400 x 2600
8 of 13
staff4900 x 2600
9 of 13
staff4900 x 2600
10 of 13
staff4900 x 2600
11 of 13
staff4900 x 2600
12 of 13
staff4900 x 2600
13 of 13
visitor5400 x 2600
5 of 11
visitor5400 x 2600
4 of 11
visitor5400 x 2600
3 of 11
visitor5400 x 2600
2 of 11
visitor5400 x 2600
1 of 11
disabled5400 x 2400
visitor4900 x 2600
6 of 11
visitor4900 x 2600
7 of 11
visitor4900 x 2600
8 of 11
visitor4900 x 2600
9 of 11
visitor4900 x 2600
10 of 11
visitor4900 x 2600
11 of 11
proposedchildcare
FFL: 26.150(tbc)
bikes
ramp
SIGN 1.8m ACOUSTIC FENCE
1.5m POOL FENCE
(AS PER ACOUSTIC REPORT)
N
Proposed Site PlanScale 1:200
Use written dimensions only. Do not scale drawings fromplans
Building zone is to be cleared of any vegetation and trees tosuit - check on site.
All survey data taken from DWG/PDF copy by others.Cyber Drafting & Design take no responsibilty of theproposed slab & pad levels due to the possibility of in-accurancy of the discloure plan.
Verify all bearing and dimensions on site prior toconstruction.All missing pegs to be re-instated prior to any construction.Notify head contractor immediately of any descrepencies insetout dimensions. Do not strat construction until allboundaries are confirmed.
Ensure all drawings and accompanying details and/orspecifcations have been stamped as 'Approved' by therelevant local authorities prior to use.
All site drainage to be graded to rubble pits or approvedsite drainage pits at a min grade of 1:100 (1%) andconnected to legal point of discharge in compliance withAS/NZ 3500 &/or NCC BCA vol. 2. parts 3.1.2 & 3.5.2
notes:
site: Lot 523number: 1-3street: Forrest Roadlocality: Padbury WA 6025city: Joondalupplan: 9938
propertydescription
area: 1635m² (1051m² / 583m²)
PRELIMINARY DRAWINGS - NOT FOR CONSTRUCTION.
I/ WE APPROVE THESE DRAWINGS TO BE CORRECT AS PERCONTRACT
rev. Coulston Groupdate description
client details:
N2SIGNATURE
SIGNATURE
drawn:
-2 of 7
DATE
DATE
Sheet SizePROPOSED SITEPLAN 17085
designed:
A2
sheets in set
drawing scales
checked:
fasade typeorientation drawing job numberwind rating drawing title drawn date:
JM RT
Dimensions shall not be obtained by scaling.All dimensions are in millimeters unless notedotherwise. Setout dimensions shall be verifiedon site prior to any work being carried out. Anyproblems shall be directed to the builder forclarification & correction
I/ WE APPROVE THESE DRAWINGS TO BE CORRECT AS PERCONTRACT
rev. Coulston Groupdate description
client details:
N2SIGNATURE
SIGNATURE
drawn:
-3 of 7
DATE
DATE
Sheet SizePROPOSEDGROUND FLOOR 17085
designed:
A2
sheets in set
drawing scales
checked:
fasade typeorientation drawing job numberwind rating drawing title drawn date:
JM RT
Dimensions shall not be obtained by scaling.All dimensions are in millimeters unless notedotherwise. Setout dimensions shall be verifiedon site prior to any work being carried out. Anyproblems shall be directed to the builder forclarification & correction
I/ WE APPROVE THESE DRAWINGS TO BE CORRECT AS PERCONTRACT
rev. Coulston Groupdate description
client details:
N2SIGNATURE
SIGNATURE
drawn:
-4 of 7
DATE
DATE
Sheet SizePROPOSED FIRSTFLOOR 17085
designed:
A2
sheets in set
drawing scales
checked:
fasade typeorientation drawing job numberwind rating drawing title drawn date:
JM RT
Dimensions shall not be obtained by scaling.All dimensions are in millimeters unless notedotherwise. Setout dimensions shall be verifiedon site prior to any work being carried out. Anyproblems shall be directed to the builder forclarification & correction
F 06/10/17 Updated DA PlansE 21/09/17 Updated DA Plans
WEATHERTEX, ECOGROOVE SMOOTH 150mm
STORM (PGH BRICKS & PAVERS)
WEATHERTEX, WEATHERGROOVE SMOOTH 150mm
WEATHERTEX, VGROOVE NATURAL 300mm
COLORBOND, SURFMIST
COLORBOND, BASALT
DIESKAU (DULUX)
WHITE DUCK (DULUX)
TRANQUIL RETREAT 1/2 STRENGTH (DULUX)
POSTBOY (DULUX)
W1
W2
W3
W4
W5
W6PENSIVE QUARTER (DULUX)
BRICKWORK
VERTICAL CLADDING
HORIZONTAL CLADDING
TEXTURE COATED FC
HORIZONTAL CLADDING,FEATURE
ROOF
FASCIA / GUTTER
Finishes Schedule
RENDERED BRICKWORK
2,74
02,
740
selected brickwork finish rendered brickwork
selected horizontal claddingmetal gutter& fascia
10° pitch colorbond roof
5° pitch colorbond rooftimber pergola
u/s ceiling
slab level
u/s trusses
ff level
W5
W5
W5
W1W1
W4
W2
W6W5
2,74
02,
740
solar panels
u/s ceiling
slab leveln.g.l
u/s trusses
ff level
W4
W4 W4
W3
W3
W2
W4
W5W4
W1
1 South ElevationScale 1:100
2 West ElevationScale 1:100
PRELIMINARY DRAWINGS - NOT FOR CONSTRUCTION.
I/ WE APPROVE THESE DRAWINGS TO BE CORRECT AS PERCONTRACT
rev. Coulston Groupdate description
client details:
N2SIGNATURE
SIGNATURE
drawn:
-5 of 7
DATE
DATE
Sheet SizePROPOSEDELEVATIONS 17085
designed:
A2
sheets in set
drawing scales
checked:
fasade typeorientation drawing job numberwind rating drawing title drawn date:
JM RT
Dimensions shall not be obtained by scaling.All dimensions are in millimeters unless notedotherwise. Setout dimensions shall be verifiedon site prior to any work being carried out. Anyproblems shall be directed to the builder forclarification & correction
F 06/10/17 Updated DA PlansE 21/09/17 Updated DA Plans
WEATHERTEX, ECOGROOVE SMOOTH 150mm
STORM (PGH BRICKS & PAVERS)
WEATHERTEX, WEATHERGROOVE SMOOTH 150mm
WEATHERTEX, VGROOVE NATURAL 300mm
COLORBOND, SURFMIST
COLORBOND, BASALT
DIESKAU (DULUX)
WHITE DUCK (DULUX)
TRANQUIL RETREAT 1/2 STRENGTH (DULUX)
POSTBOY (DULUX)
W1
W2
W3
W4
W5
W6PENSIVE QUARTER (DULUX)
BRICKWORK
VERTICAL CLADDING
HORIZONTAL CLADDING
TEXTURE COATED FC
HORIZONTAL CLADDING,FEATURE
ROOF
FASCIA / GUTTER
Finishes Schedule
RENDERED BRICKWORK
2,74
02,
740
rainwater tank
1800 high rendered brick walllouvred screen 1600 high texture coated wall
1600 high perspex screen
10° pitch colorbond roof
u/s ceiling
slab level
u/s trusses
ff levelW1
W4W5
W5
2,74
02,
740
u/s ceiling
slab level
n.g.l
u/s trusses
ff level
fg fg fg
fg
3 North ElevationScale 1:100
4 East ElevationScale 1:100
PRELIMINARY DRAWINGS - NOT FOR CONSTRUCTION.
I/ WE APPROVE THESE DRAWINGS TO BE CORRECT AS PERCONTRACT
rev. Coulston Groupdate description
client details:
N2SIGNATURE
SIGNATURE
drawn:
-6 of 7
DATE
DATE
Sheet SizePROPOSEDELEVATIONS 17085
designed:
A2
sheets in set
drawing scales
checked:
fasade typeorientation drawing job numberwind rating drawing title drawn date:
JM RT
Dimensions shall not be obtained by scaling.All dimensions are in millimeters unless notedotherwise. Setout dimensions shall be verifiedon site prior to any work being carried out. Anyproblems shall be directed to the builder forclarification & correction