This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
99
Coverage chart - Campo de aplicaciones n ≈ 3450 rpm
500
120 140 100 80 60 40 U.S. g.p.m. 0
100 80 60 40 20
400 300 200 100 24 8 16
Imp. g.p.m.
150
200
100
50
0
50
70
60
40
30
20
10
0
0
0 32 0
MXH 2 MXH 4 MXH 8 MXH 16
H
m /h l/min
3
Q
m
ft
MXH
72.833/2
Horizontal multi-stage close coupled pumps in stainless steelBombas multicelulares horizontales monobloc de acero inoxidable
MXH 2,4,8,16 60 Hz
100
ConstructionHorizontal multi-stage close coupled pumps in chrome-nickel stain-less steel.Compact and robust construction, without protruding flange and withsingle-piece lantern bracket and base.Single-piece barrel casing, with front suction port above pumps axisand radial delivery at top.Filling and draining plugs on the middle of the pump, accessible fromany side (like the terminal box).
Version with frequency converter (on request)
ApplicationsFor water supply.For clean liquids, without abrasives, which are non-aggressive forstainless steel (with suitable seal materials, on request).Universal pump, for domestic use, for civil and industrial applications,for garden use and irrigation.
Operating conditionsLiquid temperature from - 15 °C to + 110 °C.Ambient temperature up to 40 °C.Maximum permissible pressure in the pump casing: 8 bar.Continuous duty.
Motor2-pole induction motor, 60 Hz (n = 3450 rpm).MXH: three-phase 220/380 V, 220/440 V, up to 3 kW;
380/660 V, from 3,7 to 4 kW;MXHM: single-phase 110 V, 127 V, 220 V, 110/220 V.
with thermal protector up to 1.1 kW only 220V.Capacitor inside the terminal box.
Insulation class F. Protection IP 54.Motor suitable for operation with frequency converter from 1,1 kW.Classification scheme IE3 for three-phase motor from 0,75 kW.Constructed in accordance with EN 60034-1, EN 60034-30-1.
EN 60335-1, EN 60335-2-41.
Special features on request- Other voltages. - Protection IP 55.- Special mechanical seal- Seal rings in FPM.- Higher or lower liquid or ambient temperatures.- Motor suitable for operation with frequency converter up to 0,75 kW.
MaterialsComponent MaterialPump casing Cr-Ni steel 1.4301 EN 10088 (AISI 304)Stage casing Cr-Ni steel 1.4301 EN 10088 (AISI 304)Wear ring PTFEImpeller Cr-Ni steel 1.4301 EN 10088 (AISI 304)Casing cover Cr-Ni steel 1.4301 EN 10088 (AISI 304)Spacer sleeve Cr-Ni steel 1.4301 EN 10088 (AISI 304)Pump shaft Cr-Ni steel 1.4305 EN 10088 (AISI 303)Plug Cr-Ni steel 1.4305 EN 10088 (AISI 303)Mechanical seal Ceramic alumina, carbon, EPDMISO 3069 - KU (Other materials on request)
MXH 2,4,8,16 60 Hz
EjecuciónBombas multicelulares horizontales monobloc de acero inoxidable alcromo-níquel.Construcción compacta y robusta, sin brida sobresaliente y acopla-miento bomba motor único con pie soporte.Cuerpo bomba en una sola pieza, abierto por un solo lado (barrielcasing), con boca de aspiración frontal sobre el eje de la bomba y bocade impulsión radial en la parte superior.Tapones de cebado y vaciado en posiciones medias, accesibles desdecada lado (como la tapa de bornes).
Versión con variador de frecuencia (bajo demanda)
AplicacionesPara aprovisionamiento de agua.Para líquidos limpios, sin partes abrasivas, no agresivos para el aceroinoxidable (con adaptación, bajo demanda, de los materiales del sellomecánico).Bomba universal, para uso doméstico, para aplicaciones civiles e indu-striales, para jardinería e irrigación.
Límites de empleoTemperatura líquido de - 15 °C a + 110 °C.Temperatura ambiente hasta 40 °C.Presión máxima admitida en el cuerpo de la bomba: 8 bar.Servicio continuo.
MotorMotor a inducción 2 polos, 60 Hz (n = 3450 1/min).MXH: trifásico 220/380 V, 220/440 V, hasta 3 kW;
380/660 V, de 3,7 a 4 kW;MXHM: monofásico 110 V, 127 V, 220 V, 110/220 V.
con protector térmico hasta 1,1 kW sólo para 220V.Condensador incorporado en la caja de bornes.
Aislamiento clase F. Protección IP 54.Motor preparado al funcionamiento con convertidor de frecuencia de1,1 kW.Clase alta eficiencia IE3 para motor trifásico de 0,75 kW.Ejecución según: IEN 60034-1; EN 60034-30-1.
EN 60335-1, EN 60335-2-41.
Otras ejecuciones bajo demanda- Otras tensiones.- Protección IP 55.- Sello mecánico especial.- Anillos de cierre cuerpo bomba en FPM.- Para líquidos o ambientes con temperaturas más elevadas o más bajas.- Motor preparado al funcionamiento con convertidor de frecuencia
hasta 0,75 kW.
MaterialesComponentes MaterialesCuerpo bomba Acero al Cr-Ni 1.4301 EN 10088 (AISI 304)Cuerpo elemento Acero al Cr-Ni 1.4301 EN 10088 (AISI 304)Anillo de cierre rodete PTFERodete Acero al Cr-Ni 1.4301 EN 10088 (AISI 304)Tapa del cuerpo Acero al Cr-Ni 1.4301 EN 10088 (AISI 304)Manguito distanciador Acero al Cr-Ni 1.4301 EN 10088 (AISI 304)Eje bomba Acero al Cr-Ni 1.4305 EN 10088 (AISI 303)Tapón Acero al Cr-Ni 1.4305 EN 10088 (AISI 303)Sello mecánico Cerámica alúmina, carbón, EPDMsegún ISO 3069 - KU (Otros materiales bajo demanda)
101
Pumps with frequency converter
The MXH EI pumps are available with power from 0,55 kW up to 4kW, the pumps are equipped with I-MAT installed on board whichallows to realize a variable-speed system extremely compact andefficient, ideal in applications of water supply and in the distribution ofhot and cold water. The pump is equipped with transducerssuitable for operation and is alreadyprogrammed at the factory.
Advantages- Energy saving- Compact design- Easy to use- Programmable to suit the system
requirements- Reliability
CostructionThe system comprises of:- Pump- Induction motor- I-MAT Frequency converter- Motor adapter for the motor mounting
of the frequency converter- Connection cable between frequency
converter and induction motor- Transducers
Main featuresRated motor power output from 0,55 kW to 4 kWControl range from 1750 to 3450 rpm (2-pole)Protection against dry runningProtection against operations with closed valve portsProtection against system leakagesProtection against overcurrent in the motorProtection agains overvoltage and undervoltage of the power supplyProtection against current unbalances between phases
Bomba a velocidad variable
La bomba MXH EI se encuentra disponible con potencias de 0,55 kW a 4kW y llevan incorporado un variador I-MAT que permite realizar un sistemade velocidad variable extremadamente compacto y eficiente, ideal paraaplicaciones de abastecimiento de agua y la distribución de agua fría y
caliente.Bomba eléctrica es suministrada con untransductor de presión idóneo para el modooperación que escoja el cliente y programadodirectamente desde fábrica
Ventajas- Ahorro de energía- Diseño compacto- Fácil de usar- Programable para las necesidades delsistema
- Fiabilidad
Construcción- El sistema está compuesto por:- Bomba- Motor de inducción- I-MAT variador de frecuencia- Adaptador del motor para el montaje delvariador de frecuencia
- Cable de conexión entre en variador y labomba eléctrica
- Transductores
Límites de utilizaciónPotencia nominal del motor desde 0,55 kW hasta 4 kWRango de control desde 1750 hasta 3450 rpm (2 polos)Protección contra el funcionamiento en secoProtección contra el funcionamiento con válvula cerradaProtección contra fugas del sistemaProtección contra sobrecorriente del motorProtección contra sobrevoltaje o bajovoltaje de la red de alimentaciónProtección contra el desequilibrio de fases
MXH EI 60 Hz
Constant pressure mode with pressure transducer
In this mode, the system maintains the preset pres-sure when the flow required by the installationchanges.
Proportional pressure mode with pressure transducer
In this mode the system changes the working pres-sure according to the required flow rate.
Constant flow mode with flow meter
In this mode the system maintains a constant flowrate value in a point of the installation according tothe required pressure.
Fixed speed mode with setting of the speed preferential rotation.
In this mode, by changing the working frequency,you may choose any operational curve includedwithin the working range.
Constant temperature modewith temperature transducerIn this mode the system keeps the temperatureconstant inside a system by changing the speed ofthe pump.
Modo presión constante con sensor de presión
En el modo de presión constante, el sistema mantie-ne la presión prefijada cuando cambia el caudal porlos cambios de la instalación.
Modo presión proporcional con sensor de presión
En el modo de presión proporcional, el sistema cam-bia la presión de trabajo de acuerdo al caudal reque-rido.
Modo caudal constante con medidor de caudal
En el modo caudal constante el sistema mantiene elcaudal constante en un punto de la instalación deacuerdo a la presión requerida.
Modo velocidad fija con el ajuste de la velocidad de rotación preferencial
En el modo velocidad fija, cambiando la frecuenciade trabajo, se puede escoger cualquier curva opera-tiva dentro del rango de trabajo de la bomba.
Modo temperatura constantecon sensor de temperaturaEn este modo el sistema mantiene la temperaturaconstante dentro de un sistema cambiando la veloci-dad de la bomba.
Operating modes Modos de operaciónH
Q
H
Q
H
Q
H
max
min
+-
+-
+ -
+-
102
Performance - Prestaciones n ≈ 3450 rpm
16
33
49,5
66
15,2
31
47
63
14,5
30
45,5
60,5
13,7
28,5
43,5
58
13
27
41
55
12
25,5
38,5
51,5
10,7
23,5
35,5
47,5
9,6
21
32
43
8,5
19
28,5
38,5
7
16
24
33
MXH 201-60E
MXH 202-60/A
MXH 203-60/B
MXH 204-60/C
MXHM 201-60E
MXHM 202-60/A
MXHM 203-60/A
MXHM 204-60
kW
0,25
0,55
0,75
1,1
HP
0,34
0,75
1
1,5
Qm /h
l/min
H m
3
3 ~ 1 ~ P2
58,341,6
0
0
1
16,6
1,5
25
2
33,3
2,5 3
50
3,5 4
66,6
4,5
75
5
83,3
16
32,5
49
65,5
14,5
29,5
45,5
60
14
29
44,5
59
13,5
28,5
43,5
57,5
13
27,5
42
56
11,7
26
39,5
52,5
10,2
23,5
36
48,5
8,5
20,5
31,5
42,5
6,5
17
26,5
35,5
4
12,5
20
26
MXH 401-60E
MXH 402-60/B
MXH 403-60/C
MXH 404-60/A
MXHM 401-60E
MXHM 402-60/A
MXHM 403-60
MXHM 404-60
kW
0,33
0,75
1,1
1,5
HP
0,45
1
1,5
2
Qm /h
l/min
H m
3
3 ~ 1 ~ P2
10066,6
0
0
2,5
41,6
3
50
3,5
58,3
4 5
83,3
6 7
116
8
133
9
150
16,5
33,5
51
69
14,4
30,4
45
60
14
29
42,5
57,5
12,3
26,5
38,5
53
11,3
25
36,5
50,5
10
23
33,5
47
8,8
20,5
30,5
43
7,3
18
26,5
38
5,6
15
22,5
31
MXH 801-60/A
MXH 802-60/A
MXH 803-60/B
MXH 804-60/B
MXHM 801-60/A
MXHM 802-60
MXHM 803-60
kW
0,55
1,5
1,8
2,2
HP
0,75
2
2,5
3
Qm /h
l/min
H m
3
3 ~ 1 ~ P2
200166
0
0
6,5
108
15,6
31,3
47
63
5
83,3
8
133
10 11
183
12 13
216
14
233
15
250
35
52,5
70
33
49,5
66
31,8
47,7
63,5
30,2
45,3
60,4
28,3
42,5
56,5
26
39
52
23,5
35,2
47
20
30
40
15,8
23,7
31,5
MXH 1602-60/B
MXH 1603-60/A
MXH 1604-60/B
kW
2,2
3
4
HP
3
4
5,5
Qm /h
l/min
H m
3
3 ~ P2
350250
0
0
6
100
9
150
12
200
15 18
300
21 24
400
27
450
Test results with clean cold water, without gas content.Resultados de las pruebas con agua fría y limpia, sin gas.
MXH 2,4,8,16 60 Hz
Rated currents - Intensidades nominales
P2 Rated motor power output.Potencia nominal del motor.
IA/IN D.O.L. starting current / Rated currentIntensidad de arranque / Intensidad nominal
0,250,330,550,751,11,51,8
kW
0,340,450,75
11,52
2,5
2,32,85
6,28,5
10,613,5
HP IN A220V
44,88,7
10,714,7
--
IN A127V
single-phase - monofásico1~
4,65,610
12,4---
IN A110V
--
9.2/4.712.5/6.4
---
IN A110/220V
1,82,73,12,93
3,84,5
IA/IN
0,250,330,550,751,11,51,82,234
kW
0,340,450,75
11,52
2,534
5,5
1,7/12/1,2
3,3/1,94,5/2,65,7/3,37,4/4,3
10,0/5,811,1/6,413,4/7,7
HP IN A220/380V
three-phase - trifásico3~
---------
11,2/6,5
IN A380/660V
1,8/1,12,2/1,33,5/2,04,7/2,76,0/3,57,8/4,5
10,4/6,111,6/6,714,0/8,1
IN A220/440V
4,74
4,35,65,47,39
8,48,49,2
IA/IN
P2 Rated motor power output.Potencia nominal del motor.
+ 0,5 m security margin on NPSH-value is necessary.
Para el valor del NPSH se recomienda un margen de seguridad de + 0,5 m.
Tolerances according to UNI EN ISO 9906:2012.Tolerancias según UNI EN ISO 9906:2012.
103
Dimensions and weights - Dimensiones y pesos
TYPETIPO
TYPETIPO
● Standard dimensions - Dimensiones estándar ❏ Cannot constructed - Non fatibles
● Standard dimensions - Dimensiones estándar ❏ Cannot constructed - Non fatibles
331
357
357
331
357
381
MXH 201-60E - MXHM 201-60E
MXH 202-60/A - MXHM 202-60/A
MXH 203-60/B - MXHM 203-60/A
MXH 401-60E - MXHM 401-60E
MXH 402-60/B - MXHM 402-60/A
MXH 801-60/A - MXHM 801-60/A
94
94
94
94
94
118
fM a
mm
MXH MXHM
6,6
9,1
11,3
6,6
10,8
9,7
6,7
10,1
11,5
6,7
11
10,5
kg
176
192
192
176
192
192
H
98,5
112
112
98,5
112
112
w1
-
197
197
-
197
197
H*
●
●
116
●
116
●
127V
●
●
116
●
116
●
110V
●
●
●
●
●
●
220V
❏
116
131
❏
131
116
110/220V
ISO 228
DN2DN1
G 1
G 1
G 1
G 1
G 1
G 1
G 1 1/4
G 1 1/4
G 1 1/4
G 1 1/4
G 1 1/4
G 1 1/2
ISO 228
DN2DN1
453
453
453
453
493
522
504
575
612
MXH 204-60/C - MXHM 204-60
MXH 403-60/C - MXHM 403-60
MXH 404-60/A - MXHM 404-60
MXH 802-60/A - MXHM 802-60
MXH 803-60/B - MXHM 803-60
MXH 804-60/B
MXH 1602-60/B
MXH 1603-60/A
MXH 1604-60/B
118
118
118
118
118
148
128
128
166
fM a
mm
G 1
G 1
G 1
G 1
G 1
G 1
G 1 1/2
G 1 1/2
G 1 1/2
G 1 1/4
G 1 1/4
G 1 1/4
G 1 1/2
G 1 1/2
G 1 1/2
G 2
G 2
G 2
MXH MXHM
-
-
18,5
18
18,3
19,8
18,3
30
31
17,7
17,2
19,2
18,9
19,3
-
-
kg
127
127
127
127
127
127
117
132
132
h1
57
57
57
57
57
57
70
70
70
88
88
88
88
88
88
101
113
113
h2
10
10
10
10
10
10
10
12
12
m3
31
31
31
31
31
31
31
45
45
m1w
210
210
210
210
210
210
210
235
235
H
167
167
167
167
167
167
167
232
232
w1
215
215
215
215
215
-
-
-
-
H*
131
131
❏
❏
❏
-
-
-
-
127V
❏
❏
❏
❏
❏
-
-
-
-
110V
●
●
●
●
131
-
-
-
-
220V
❏
❏
❏
❏
❏
-
-
-
-
110/220V
AR
AS
88
28
4.93.209
8
w1
DN
1(1)
fM
DN 2
a
10
30
112
146
57
H
9
160
127
H*
(2)
AR
DN 2
a
fM
DN
1
w1
m1
m3w
3.93.020/1
10,5 10
112
h1h2
H
146
160
30,5
H*
AS
(1)
(2)
(1) Filling (2) Draining Cebado Vaciado
MXH 2,4,8,16 60 Hz
420
420
420
444
MXH EI 202-60/A
MXH EI 203-60/B
MXH EI 402-60/B
MXH EI 801-60/A
94
94
94
118
fM a
mm
G 1
G 1
G 1
G 1
G 1 1/4
G 1 1/4
G 1 1/4
G 1 1/2
ISO 228DN2DN1
ISO 228DN2DN1
14,7
16,9
16,4
15,3
kg
349
349
349
349
H
112
112
112
112
w1
485
485
485
485
525
554
504
590
627
MXH EI 204-60/C
MXH EI 403-60/C
MXH EI 404-60/A
MXH EI 802-60/A
MXH EI 803-60/B
MXH EI 804-60/B
MXH EI 1602-60/B
MXH EI 1603-60/A
MXH EI 1604-60/B
118
118
118
118
118
148
128
128
166
fM a
mm
190
190
190
190
190
190
190
210
210
AG
105
105
105
105
105
105
105
118
118
AS
G 1
G 1
G 1
G 1
G 1
G 1
G 1 1/2
G 1 1/2
G 1 1/2
G 1 1/4
G 1 1/4
G 1 1/4
G 1 1/2
G 1 1/2
G 1 1/2
G 2
G 2
G 2
31,3
30,8
32,3
28,6
31
34,2
31
34,7
48,8
kg
127
127
127
127
127
127
117
132
132
h1
108
108
108
108
108
108
122
122
122
88
88
88
88
88
88
101
113
113
h2w
31
31
31
31
31
31
31
45
45
10
10
10
10
10
10
10
12
12
30,5
30,5
30,5
30,5
30,5
30,5
30,5
38
38
167
167
167
167
167
167
167
232
232
m1 m3 b w1
368
368
368
368
368
368
368
391
391
H
88
28
4.93.209/1
8
w1
DN
1
(1)
fM
DN 2
a
10
30
112
146
H
9
16012
710
8
(2)
DN 2
a
fM
DN
1
w1
m1
m3w
3.93.020/2
10,5 10
112
h1h2 H
146
160
b
(1)
(2)
190105
AG
AS
104
Dimensions and weights - Dimensiones y pesos
(1) Filling (2) Draining Cebado Vaciado
MXH EI 2,4,8,16 60 Hz
TYPETIPO
TYPETIPO
105
Characteristic curves - Curvas Características n ≈ 3450 rpm
4
2
10
50
30
20
10
70 50 30 80 60 40 20
Imp. g.p.m. 15 10 5
150
200
100
50
0
4 3 2 1
4 3 2 1
50
60
70
40
30
20
10
0 0 5 0
0
0
0 5 0
20 15 10 5 U.S. g.p.m. 0
9
9
7
7
5
5 3
3
60
40
30
20
140 100 60 160 120 80 40
Imp. g.p.m. 30 20 10
150
200
100
50
0
8 6 4 2
8 6 4 2
50
70
60
40
30
20
10
10
0
2
4
0 10 0
0
0
0 10 0
40 30 20 10 U.S. g.p.m. 0
250
4
5
2
40
70
60 50 40 30 20 U.S. g.p.m. 0
15
5
50 40 30 20
200 150 100 50
10
10
5
5
15
Imp. g.p.m.
50
30
150
200
100
50
0
50
70
60
40
30
20
10
10 3
1
0
0
0
0 15 0
72.580/1 72.581/1
72.582/1
MXH 202-60
MXH 201-60
MXH 203-60
MXH 204-60
MXH 403-60
MXH 404-60
MXH 402-60
MXH 401-60
MXH 803-60
MXH 804-60
MXH 802-60
MXH 801-60
H
m /h l/min
3
Q
m /h 3 Q
m
ft
η %
NPSH m
ft
H
m /h l/min
3
Q
m /h 3 Q
m
ft
η %
NPSH m
ft
H
m /h l/min
3
Q
m /h 3 Q
m
ft
η %
NPSH m
ft
MXH 2
MXH 8
MXH 4
500
6
8
2
40
70
120 1 00 8 0 6 0 4 0 U.S. g.p.m. 0
15
5
100 8 0 6 0 4 0
400 3 00 2 00 1 00
20
20
10
10
30
Imp. g.p.m.
50
30
150
200
100
50
0
50
70
60
40
30
20
10
10 4
0
0
0
0
0 30 0
72.582/2
MXH 1602-60
MXH 1603-60
MXH 1604-60
H
m /h l/min
3
Q
m /h 3 Q
m
ft
η %
NPSH ft
MXH 16
MXH 2,4,8,16 60 Hz
106
Features - Características constructivas
Extra safetyagainst running dry, with the suction port above pump axis.
ReliableAll hydraulic parts in contact with the pumped liquid are ofstainless steel. For liquids from -15 °C to 110 °C.
RobustSingle-piece, thick barrel casing.
CompactSingle-piece lantern bracket and base.Without protruding flange.
Greater protectionAgainst leakage, with the pump casing cover separated fromthe motor shield. Possibility of inspecting the seal through the side aperturesbetween the two walls.Greater protection against water entering the motor from outsi-de provided by an extension of the pump casing around thelantern bracket.
3.93.001
MXH 2,4,8,16 60 Hz
Más seguridadContra el funcionamiento en seco, con la boca de aspiraciónsobre el eje de la bomba.
FiableTodas las partes hidráulicas en contacto con el líquido son deacero inoxidable. Para líquidos de -15 °C a +110 °C.
RobustaCuerpo bomba de una sola pieza de grueso espesor, abiertopor un solo lado.
CompactaAcoplamiento bomba motor y base soporte de una sola pieza.Sin brida sobresaliente.
Mayor protecciónContra las pérdidas del cierre, con la tapa de la bomba sepa-rada de la tapa del motor. Posibilidad de inspección del sellomecánico a través de la abertura lateral entre las dos paredes.Mayor protección contra la penetración del agua en el motor,obtenida por medio del cuerpo bomba prolongad o sobre elacoplamiento.
107
MXHL 60 Hz AISI 316
604020U.S. g.p.m.0
604020
3002001008 124 1610 146 18
Imp. g.p.m.
150
200
100
50
0
50
70
60
40
30
20
10
0
0
00
MXHL 2 MXHL 4 MXHL 8
H
m /hl/min
3
Q
m
ft
MXHL
72.833/2
Coverage chart - Campo de aplicaciones n ≈ 3450 rpm
Horizontal multi-stage close coupled pumps in stainless steelBombas multicelulares horizontales monobloc de acero inoxidable
108
MXHL 60 Hz AISI 316
ConstructionHorizontal multi-stage close coupled pumps in chrome-nickel-molyb-denum stainless steel AISI 316L.Compact and robust construction, without protruding flange and withsingle-piece lantern bracket and base.Single-piece barrel casing, with front suction port above pumps axisand radial delivery at top.Filling and draining plugs on the middle of the pump, accessible fromany side (like the terminal box).
Version with frequency converter (on request)
ApplicationsFor water supply.For clean liquids, without abrasives, which are non-aggressive forstainless steel (with suitable seal materials, on request).Universal pump, for domestic use, for civil and industrial applications,for garden use and irrigation.
Operating conditionsLiquid temperature from - 15 °C to + 110 °C.Ambient temperature up to 40 °C.Maximum permissible pressure in the pump casing: 8 bar.Continuous duty.
with thermal protector up to 1.1 kW only 220V.Capacitor inside the terminal box.
Insulation class F. Protection IP 54.Motor suitable for operation with frequency converter from 1,1 kW.Classification scheme IE3 for three-phase motor from 0,75 kW.Constructed in accordance with EN 60034-1, EN 60034-30-1.
EN 60335-1, EN 60335-2-41.
Special features on request- Other voltages. - Protection IP 55.- Special mechanical seal- Seal rings in FPM.- Higher or lower liquid or ambient temperatures.- Motor suitable for operation with frequency converter up to 0,75 kW.
MaterialsComponent MaterialPump casing Cr-Ni-Mo steel 1.4404 EN 10088 (AISI 316L)Stage casing Cr-Ni-Mo steel 1.4404 EN 10088 (AISI 316L)Wear ring PTFEImpeller Cr-Ni-Mo steel 1.4404 EN 10088 (AISI 316L)Casing cover Cr-Ni-Mo steel 1.4404 EN 10088 (AISI 316L)Spacer sleeve Cr-Ni-Mo steel 1.4404 EN 10088 (AISI 316L)Pump shaft Cr-Ni-Mo steel 1.4404 EN 10088 (AISI 316L)Plug Cr-Ni-Mo steel 1.4404 EN 10088 (AISI 316L)Mechanical seal Ceramic alumina, carbon, EPDMISO 3069 - KU (Other materials on request)
EjecuciónBombas multicelulares horizontales monobloc de acero inoxidable alcromo-níquel-molibdeno AISI 316LConstrucción compacta y robusta, sin brida sobresaliente y acopla-miento bomba motor único con pie soporte.Cuerpo bomba en una sola pieza, abierto por un solo lado (barrielcasing), con boca de aspiración frontal sobre el eje de la bomba y bocade impulsión radial en la parte superior.Tapones de cebado y vaciado en posiciones medias, accesibles desdecada lado (como la tapa de bornes).Versión variador de frecuencia (bajo demanda)
AplicacionesPara aprovisionamiento de agua.Para líquidos limpios, sin partes abrasivas, no agresivos para el aceroinoxidable (con adaptación, bajo demanda, de los materiales del sellomecánico).Bomba universal, para uso doméstico, para aplicaciones civiles e indu-striales, para jardinería e irrigación.
Límites de empleoTemperatura líquido de - 15 °C a + 110 °C.Temperatura ambiente hasta 40 °C.Presión máxima admitida en el cuerpo de la bomba: 8 bar.Servicio continuo.
con protector térmico hasta 1,1 kW sólo para 220V.Condensador incorporado en la caja de bornes.
Aislamiento clase F. Protección IP 54.Motor preparado al funcionamiento con convertidor de frecuencia de1,1 kW.Clase alta eficiencia IE3 para motor trifásico de 0,75 kW.Ejecución según: EN 60034-1; EN 60034-30-1.
EN 60335-1, EN 60335-2-41.
Otras ejecuciones bajo demandaOtras tensiones.Protección IP 55.Sello mecánico especial.Anillos de cierre cuerpo bomba en FPM.Para líquidos o ambientes con temperaturas más elevadas o más bajas.Motor preparado al funcionamiento con convertidor de frecuencia hasta0,75 kW.
MaterialesComponentes MaterialesCuerpo bomba Acero al Cr-Ni-Mo 1.4404 EN 10088 (AISI 316L)Cuerpo elemento Acero al Cr-Ni-Mo 1.4404 EN 10088 (AISI 316L)Anillo de cierre rodete PTFERodete Acero al Cr-Ni-Mo 1.4404 EN 10088 (AISI 316L)Tapa del cuerpo Acero al Cr-Ni-Mo 1.4404 EN 10088 (AISI 316L)Manguito distanciador Acero al Cr-Ni-Mo 1.4404 EN 10088 (AISI 316L)Eje bomba Acero al Cr-Ni-Mo 1.4404 EN 10088 (AISI 316L)Tapón Acero al Cr-Ni-Mo 1.4404 EN 10088 (AISI 316L)Sello mecánico Cerámica alúmina, carbón, EPDMsegún ISO 3069 - KU (Otros materiales bajo demanda)
MXHL 60 Hz AISI 316
109
Pumps with frequency converter
The MXHL EI pumps are available with power from 0,55 kW up to 2,2kW, the pumps are equipped with I-MAT installed on board whichallows to realize a variable-speed system extremely compact andefficient, ideal in applications of water supply and in the distribution ofhot and cold water. The pump is equipped with transducerssuitable for operation and is alreadyprogrammed at the factory.
Advantages- Energy saving- Compact design- Easy to use- Programmable to suit the system
requirements- Reliability
CostructionThe system comprises of:- Pump- Induction motor- I-MAT Frequency converter- Motor adapter for the motor mounting
of the frequency converter- Connection cable between frequency
converter and induction motor- Transducers
Main featuresRated motor power output from 0,55 kW to 2,2 kWControl range from 1750 to 3450 rpm (2-pole)Protection against dry runningProtection against operations with closed valve portsProtection against system leakagesProtection against overcurrent in the motorProtection agains overvoltage and undervoltage of the power supplyProtection against current unbalances between phases
Bomba a velocidad variable
La bomba MXHL EI se encuentra disponible con potencias de 0,55 kW a2,2 kW y llevan incorporado un variador I-MAT que permite realizar unsistema de velocidad variable extremadamente compacto y eficiente, idealpara aplicaciones de abastecimiento de agua y la distribución de agua fría
y caliente.Bomba eléctrica es suministrada con untransductor de presión idóneo para el modooperación que escoja el cliente y programadodirectamente desde fábrica
Ventajas- Ahorro de energía- Diseño compacto- Fácil de usar- Programable para las necesidades delsistema
- Fiabilidad
Construcción- El sistema está compuesto por:- Bomba- Motor de inducción- I-MAT variador de frecuencia- Adaptador del motor para el montaje delvariador de frecuencia
- Cable de conexión entre en variador y labomba eléctrica
- Transductores
Límites de utilizaciónPotencia nominal del motor desde 0,55 kW hasta 2,2 kWRango de control desde 1750 hasta 3450 rpm (2 polos)Protección contra el funcionamiento en secoProtección contra el funcionamiento con válvula cerradaProtección contra fugas del sistemaProtección contra sobrecorriente del motorProtección contra sobrevoltaje o bajovoltaje de la red de alimentaciónProtección contra el desequilibrio de fases
Constant pressure mode with pressure transducer
In this mode, the system maintains the preset pres-sure when the flow required by the installationchanges.
Proportional pressure mode with pressure transducer
In this mode the system changes the working pres-sure according to the required flow rate.
Constant flow mode with flow meter
In this mode the system maintains a constant flowrate value in a point of the installation according tothe required pressure.
Fixed speed mode with setting of the speed preferential rotation.
In this mode, by changing the working frequency,you may choose any operational curve includedwithin the working range.
Constant temperature modewith temperature transducerIn this mode the system keeps the temperatureconstant inside a system by changing the speed ofthe pump.
Modo presión constante con sensor de presión
En el modo de presión constante, el sistema mantie-ne la presión prefijada cuando cambia el caudal porlos cambios de la instalación.
Modo presión proporcional con sensor de presión
En el modo de presión proporcional, el sistema cam-bia la presión de trabajo de acuerdo al caudal reque-rido.
Modo caudal constante con medidor de caudal
En el modo caudal constante el sistema mantiene elcaudal constante en un punto de la instalación deacuerdo a la presión requerida.
Modo velocidad fija con el ajuste de la velocidad de rotación preferencial
En el modo velocidad fija, cambiando la frecuenciade trabajo, se puede escoger cualquier curva opera-tiva dentro del rango de trabajo de la bomba.
Modo temperatura constantecon sensor de temperaturaEn este modo el sistema mantiene la temperaturaconstante dentro de un sistema cambiando la veloci-dad de la bomba.
Operating modes Modos de operaciónH
Q
H
Q
H
Q
H
max
min
+-
+-
+ -
+-
110
MXHL 60 Hz AISI 316
Performance - Prestaciones n ≈ 3450 rpm
16
33
49,5
66
15,2
31
47
63
14,5
30
45,5
60,5
13,7
28,5
43,5
58
13
27
41
55
12
25,5
38,5
51,5
10,7
23,5
35,5
47,5
9,6
21
32
43
8,5
19
28,5
38,5
7
16
24
33
MXHL 201-60E
MXHL 202-60/A
MXHL 203-60/B
MXHL 204-60/C
MXHLM 201-60E
MXHLM 202-60/A
MXHLM 203-60/A
MXHLM 204-60
kW
0,25
0,55
0,75
1,1
HP
0,34
0,75
1
1,5
Qm /h
l/min
H m
3
3 ~ 1 ~ P2
58,341,6
0
0
1
16,6
1,5
25
2
33,3
2,5 3
50
3,5 4
66,6
4,5
75
5
83,3
16
32,5
49
65,5
14,5
29,5
45,5
60
14
29
44,5
59
13,5
28,5
43,5
57,5
13
27,5
42
56
11,7
26
39,5
52,5
10,2
23,5
36
48,5
8,5
20,5
31,5
42,5
6,5
17
26,5
35,5
4
12,5
20
26
MXHL 401-60E
MXHL 402-60/B
MXHL 403-60/C
MXHL 404-60/A
MXHLM 401-60E
MXHLM 402-60/A
MXHLM 403-60
MXHLM 404-60
kW
0,33
0,75
1,1
1,5
HP
0,45
1
1,5
2
Qm /h
l/min
H m
3
3 ~ 1 ~ P2
10066,6
0
0
2,5
41,6
3
50
3,5
58,3
4 5
83,3
6 7
116
8
133
9
150
16,5
33,5
51
69
14,4
30,4
45
60
14
29
42,5
57,5
12,3
26,5
38,5
53
11,3
25
36,5
50,5
10
23
33,5
47
8,8
20,5
30,5
43
7,3
18
26,5
38
5,6
15
22,5
31
MXHL 801-60/A
MXHL 802-60/A
MXHL 803-60/B
MXHL 804-60/B
MXHLM 801-60/A
MXHLM 802-60
MXHLM 803-60
kW
0,55
1,5
1,8
2,2
HP
0,75
2
2,5
3
Qm /h
l/min
H m
3
3 ~ 1 ~ P2
200166
0
0
6,5
108
15,6
31,3
47
63
5
83,3
8
133
10 11
183
12 13
216
14
233
15
250
Test results with clean cold water, without gas content.Resultados de las pruebas con agua fría y limpia, sin gas.
Rated currents - Intensidades nominales
P2 Rated motor power output.Potencia nominal del motor.
IA/IN D.O.L. starting current / Rated currentIntensidad de arranque / Intensidad nominal
0,250,330,550,751,11,51,8
kW
0,340,450,75
11,52
2,5
2,32,85
6,28,5
10,613,5
HP IN A220V
44,88,7
10,714,7
--
IN A127V
single-phase - monofásico1~
4,65,610
12,4---
IN A110V
--
9.2/4.712.5/6.4
---
IN A110/220V
1,82,73,12,93
3,84,5
IA/IN
0,250,330,550,751,11,51,82,2
kW
0,340,450,75
11,52
2,53
1,7/12/1,2
3,3/1,94,5/2,65,7/3,37,4/4,3
10,0/5,811,1/6,4
HP IN A220/380V
three-phase - trifásico3~
1,8/1,12,2/1,33,5/2,04,7/2,76,0/3,57,8/4,5
10,4/6,111,6/6,7
IN A220/440V
4,74
4,35,65,47,39
8,4
IA/IN
P2 Rated motor power output.Potencia nominal del motor.
+ 0,5 m security margin on NPSH-value is necessary.
Para el valor del NPSH se recomienda un margen de seguridad de + 0,5 m.
Tolerances according to UNI EN ISO 9906:2012.Tolerancias según UNI EN ISO 9906:2012.
111
MXHL 60 Hz AISI 316
Dimensions and weights - Dimensiones y pesos
TYPETIPO
TYPETIPO
● Standard dimensions - Dimensiones estándar ❏ Cannot constructed - Non fatibles
● Standard dimensions - Dimensiones estándar ❏ Cannot constructed - Non fatibles
331
357
357
331
357
381
MXHL 201-60E - MXHLM 201-60E
MXHL 202-60/A - MXHLM 202-60/A
MXHL 203-60/B - MXHLM 203-60/A
MXHL 401-60E - MXHLM 401-60E
MXHL 402-60/B - MXHLM 402-60/A
MXHL 801-60/A - MXHLM 801-60/A
94
94
94
94
94
118
fM a
mm
MXH MXHM
6,6
9,1
11,3
6,6
10,8
9,7
6,7
10,1
11,5
6,7
11
10,5
kg
176
192
192
176
192
192
H
98,5
112
112
98,5
112
112
w1
181
197
197
181
197
197
H*
●
●
116
●
116
●
127V
●
●
116
●
116
●
110V
●
●
●
●
●
●
220V
❏
116
131
❏
131
116
110/220V
ISO 228
DN2DN1
G 1
G 1
G 1
G 1
G 1
G 1
G 1 1/4
G 1 1/4
G 1 1/4
G 1 1/4
G 1 1/4
G 1 1/2
ISO 228
DN2DN1
453
453
453
453
493
522
MXHL 204-60/C - MXHLM 204-60
MXHL 403-60/C - MXHLM 403-60
MXHL 404-60/A - MXHLM 404-60
MXHL 802-60/A - MXHLM 802-60
MXHL 803-60/B - MXHLM 803-60
MXHL 804-60/B
118
118
118
118
118
148
fM a
mm
G 1
G 1
G 1
G 1
G 1
G 1
G 1 1/4
G 1 1/4
G 1 1/4
G 1 1/2
G 1 1/2
G 1 1/2
MXH MXHM
-
-
18,5
18
18,3
19,8
17,7
17,2
19,2
18,9
19,3
-
kg
127
127
127
127
127
127
h1
57
57
57
57
57
57
88
88
88
88
88
88
h2w
210
210
210
210
210
210
H
167
167
167
167
167
167
w1
215
215
215
215
215
-
H*
131
131
❏
❏
❏
-
127V
❏
❏
❏
❏
❏
-
110V
●
●
●
●
131
-
220V
❏
❏
❏
❏
❏
-
110/220V
AR
AS
DN 2
a
fM
DN
1
w1
31
10w
3.93.020/1
10,5 10
112
h1h2
H
146
160
30,5
H*
AS
(1)
(2)
88
28
4.93.209
8
w1
DN
1(1)
fM
DN 2
a
10
30
112
146
57
H
9
160
127
H*
(2)
AR
(1) Filling (2) Draining Cebado Vaciado
112
Characteristic curves - Curvas Características n ≈ 3450 rpm
4
2
10
50
30
20
10
70 50 30 80 60 40 20
Imp. g.p.m. 15 10 5
150
200
100
50
0
4 3 2 1
4 3 2 1
50
60
70
40
30
20
10
0 0 5 0
0
0
0 5 0
20 15 10 5 U.S. g.p.m. 0
9
9
7
7
5
5 3
3
60
40
30
20
140 100 60 160 120 80 40
Imp. g.p.m. 30 20 10
150
200
100
50
0
8 6 4 2
8 6 4 2
50
70
60
40
30
20
10
10
0
2
4
0 10 0
0
0
0 10 0
40 30 20 10 U.S. g.p.m. 0
250
4
5
2
40
70
60 50 40 30 20 U.S. g.p.m. 0
15
5
50 40 30 20
200 150 100 50
10
10
5
5
15
Imp. g.p.m.
50
30
150
200
100
50
0
50
70
60
40
30
20
10
10 3
1
0
0
0
0 15 0
72.580/1 72.581/1
72.582/1
MXHL 202-60
MXHL 201-60
MXHL 203-60
MXHL 204-60
MXHL 403-60
MXHL 404-60
MXHL 402-60
MXHL 401-60
MXHL 803-60
MXHL 804-60
MXHL 802-60
MXHL 801-60
H
m /h l/min
3
Q
m /h 3 Q
m
ft
η %
NPSH m
ft
H
m /h l/min
3
Q
m /h 3 Q
m
ft
η %
NPSH m
ft
H
m /h l/min
3
Q
m /h 3 Q
m
ft
η %
NPSH m
ft
MXHL 2
MXHL 8
MXHL 4
MXHL 60 Hz AISI 316
113
Features - Características constructivas
MXHL 60 Hz AISI 316
Extra safetyagainst running dry, with the suction port above pump axis.
ReliableAll hydraulic parts in contact with the pumped liquid are ofstainless steel. For liquids from -15 °C to 110 °C.
RobustSingle-piece, thick barrel casing.
CompactSingle-piece lantern bracket and base.Without protruding flange.
Greater protectionAgainst leakage, with the pump casing cover separated fromthe motor shield. Possibility of inspecting the seal through the side aperturesbetween the two walls.Greater protection against water entering the motor from outsi-de provided by an extension of the pump casing around thelantern bracket.
3.93.001
Más seguridadContra el funcionamiento en seco, con la boca de aspiraciónsobre el eje de la bomba.
FiableTodas las partes hidráulicas en contacto con el líquido son deacero inoxidable. Para líquidos de -15 °C a +110 °C.
RobustaCuerpo bomba de una sola pieza de grueso espesor, abiertopor un solo lado.
CompactaAcoplamiento bomba motor y base soporte de una sola pieza.Sin brida sobresaliente.
Mayor protecciónContra las pérdidas del cierre, con la tapa de la bomba sepa-rada de la tapa del motor. Posibilidad de inspección del sellomecánico a través de la abertura lateral entre las dos paredes.Mayor protección contra la penetración del agua en el motor,obtenida por medio del cuerpo bomba prolongad o sobre elacoplamiento.
114
MXH 20,32,48 60 Hz
Coverage chart - Campo de aplicaciones n ≈ 3450 rpm
ft
m
m /hl/min
H
Q3
1000
200 250
5010 30 60 70800600400200
Imp. g.p.m. 15010050
200
100
300
04020
60
70
80
90
100
110
120
40
20
30
10
0
200 250 300U.S. g.p.m. 150100500
0
00
MXH 48
MXH
MXH 32MXH 20
72.978/05
Horizontal multi-stage close coupled pumps in stainless steelBombas multicelulares horizontales monobloc de acero inoxidable
115
MaterialsComponent MaterialPump casing Cr-Ni steel 1.4301 EN 10088 (AISI 304)Stage casing Cr-Ni steel 1.4301 EN 10088 (AISI 304)Wear ring PTFEImpeller Cr-Ni steel 1.4301 EN 10088 (AISI 304)Casing cover Cr-Ni steel 1.4301 EN 10088 (AISI 304)Spacer sleeve Cr-Ni steel 1.4301 EN 10088 (AISI 304)Pump shaft Cr-Ni steel 1.4305 EN 10088 (AISI 303)Plug Cr-Ni steel 1.4305 EN 10088 (AISI 303)Mechanical seal Ceramic alumina, carbon, EPDMISO 3069 - KU (Other materials on request)
MaterialesComponentes MaterialesCuerpo bomba Acero al Cr-Ni 1.4301 EN 10088 (AISI 304)Cuerpo elemento Acero al Cr-Ni 1.4301 EN 10088 (AISI 304)Anillo de cierre rodete PTFERodete Acero al Cr-Ni 1.4301 EN 10088 (AISI 304)Tapa del cuerpo Acero al Cr-Ni 1.4301 EN 10088 (AISI 304)Manguito distanciador Acero al Cr-Ni 1.4301 EN 10088 (AISI 304)Eje bomba Acero al Cr-Ni 1.4305 EN 10088 (AISI 303)Tapón Acero al Cr-Ni 1.4305 EN 10088 (AISI 303)Sello mecánico Cerámica alúmina, carbón, EPDMISO 3069 - KU (Otros materiales bajo demanda)
ConstructionHorizontal multi-stage close coupled pumps in chrome-nickel stain-less steel.Compact and robust construction,with compact lantern bracket andmotor with feet.Single-piece barrel casing, with front suction port above pumps axisand radial delivery at top. Filling and draining plugs on the middle ofthe pump, accessible from any side (like the terminal box).Version with frequency converter (on request)
ApplicationsFor water supply.For clean liquids, without abrasives, which are non-aggressive forstainless steel (with suitable seal materials, on request).Universal pump, for civil and industrial applications, for garden useand irrigation.
Operating conditionsLiquid temperature from - 15 °C to + 110 °C.Ambient temperature up to 40 °C.Maximum permissible pressure in the pump casing: 10 bar.Continuous duty.
Motor2-pole induction motor, 60 Hz (n = 3450 rpm).MXH: three-phase 220/380 V, 220/440 V, up to 3 kW;
380/660 V, from 4 to 15 kW;Insulation class F.Protection IP 54.Motor suitable for operation with frequency converter.Classification scheme IE3 for three-phase motors from 0,75 kW.Constructed in accordance with: EN 60034-1;
EN 60034-30-1.
Special features on request- Pump with flanged ports (MXH-F).- Other voltages.- Protection IP 55.- Special mechanical seal- Seal rings in FPM.- Higher or lower ambient temperatures.
MXH 20,32,48 60 Hz
EjecuciónBombas multicelulares horizontales monobloc de acero inoxidable alcromo-níquel.Construccion compacta y muy robusta, con acoplamiento bomba motorcompacto y motor con pie soporte.Cuerpo bomba en una sola pieza, abierto por un solo lado (barrielcasing), con boca de aspiración frontal sobre el eje de la bomba y bocade impulsión radial en la parte superior.Versión con variador de frecuencia (bajo demanda)
AplicacionesPara aprovisionamiento de agua.Para líquidos limpios, sin partes abrasivas, no agresivos para el aceroinoxidable (con adaptación, bajo demanda, de los materiales del sellomecánico).Bomba universal, para aplicaciones civiles e industriales, para jardi-nería e irrigación.
Límites de empleoTemperatura líquido de - 15 °C a + 110 °C.Temperatura ambiente hasta 40 °C.Presión máxima admitida en el cuerpo de la bomba: 10 bar.Servicio continuo.
MotorMotor a inducción 2 polos, 60 Hz (n = 3450 1/min).MXH: trifásico 220/380 V, 220/440 V, hasta 3 kW;
380/660 V, de 4 a 15 kW.Aislamiento clase F. Protección IP 54.Motor preparado al funcionamiento con convertidor de frecuencia.Clase alta eficiencia IE3 para motor trifásico de 0,75 kW.Ejecución según: EN 60034-1;
EN 60034-30.
Otras ejecuciones bajo demanda- Bomba con bridas (MXH-F).- Otras tensiones.- Protección IP 55.- Sello mecánico especial.- Anillos de cierre cuerpo bomba en FPM.- Para ambientes con temperaturas más elevadas o más bajas.
DesignationMXH- F 32 04 - 60 *
SeriesNo code = threaded portsFlanged ports FRated capacity in m3/hNumber of stagesFrequency 60 Hz
Construction variants special seal code (no code = standard seal)
DesignaciónMXH- F 32 04 - 60 *
SerieSin indicación orificios roscadosOrificios con bridas FCaudal nominal en m3/hNúmero de elementosFrequencia 60 Hz
The MXH EI pumps are available with power from 1,5 kW up to 15 kW,the pumps are equipped with I-MAT installed on board which allows torealize a variable-speed system extremely compact and efficient, idealin applications of water supply and inthe distribution of hot and cold water. The pump is equipped withtransducers suitable for operation andis already programmed at the factory.
Advantages- Energy saving- Compact design- Easy to use- Programmable to suit the system
requirements- Reliability
CostructionThe system comprises of:- Pump- Induction motor- I-MAT Frequency converter- Motor adapter for the motor
mounting of the frequency converter- Connection cable between
frequency converter and inductionmotor
- Transducers
Main featuresRated motor power output from 1,5 kW to 15 kWControl range from 1750 to 3450 rpm (2-pole)Protection against dry runningProtection against operations with closed valve portsProtection against system leakagesProtection against overcurrent in the motorProtection agains overvoltage and undervoltage of the power supplyProtection against current unbalances between phases
Bomba a velocidad variable
La bomba MXH EI se encuentra disponible con potencias de 1,5 kW a15 kW y llevan incorporado un variador I-MAT que permite realizar unsistema de velocidad variable extremadamente compacto y eficiente, ideal
para aplicaciones de abastecimiento de aguay la distribución de agua fría y caliente.Bomba eléctrica es suministrada con untransductor de presión idóneo para el modooperación que escoja el cliente y programadodirectamente desde fábrica
Ventajas- Ahorro de energía- Diseño compacto- Fácil de usar- Programable para las necesidades delsistema
- Fiabilidad
Construcción- El sistema está compuesto por:- Bomba- Motor de inducción- I-MAT variador de frecuencia- Adaptador del motor para el montaje delvariador de frecuencia
- Cable de conexión entre en variador y labomba eléctrica
- Transductores
Límites de utilizaciónPotencia nominal del motor desde 1,5 kW hasta 15 kWRango de control desde 1750 hasta 3450 rpm (2 polos)Protección contra el funcionamiento en secoProtección contra el funcionamiento con válvula cerradaProtección contra fugas del sistemaProtección contra sobrecorriente del motorProtección contra sobrevoltaje o bajovoltaje de la red de alimentaciónProtección contra el desequilibrio de fases
MXH EI 20,32,48 60 Hz
Constant pressure mode with pressure transducer
In this mode, the system maintains the preset pres-sure when the flow required by the installationchanges.
Proportional pressure mode with pressure transducer
In this mode the system changes the working pres-sure according to the required flow rate.
Constant flow mode with flow meter
In this mode the system maintains a constant flowrate value in a point of the installation according tothe required pressure.
Fixed speed mode with setting of the speed preferential rotation.
In this mode, by changing the working frequency,you may choose any operational curve includedwithin the working range.
Constant temperature modewith temperature transducerIn this mode the system keeps the temperatureconstant inside a system by changing the speed ofthe pump.
Modo presión constante con sensor de presión
En el modo de presión constante, el sistema mantie-ne la presión prefijada cuando cambia el caudal porlos cambios de la instalación.
Modo presión proporcional con sensor de presión
En el modo de presión proporcional, el sistema cam-bia la presión de trabajo de acuerdo al caudal reque-rido.
Modo caudal constante con medidor de caudal
En el modo caudal constante el sistema mantiene elcaudal constante en un punto de la instalación deacuerdo a la presión requerida.
Modo velocidad fija con el ajuste de la velocidad de rotación preferencial
En el modo velocidad fija, cambiando la frecuenciade trabajo, se puede escoger cualquier curva opera-tiva dentro del rango de trabajo de la bomba.
Modo temperatura constantecon sensor de temperaturaEn este modo el sistema mantiene la temperaturaconstante dentro de un sistema cambiando la veloci-dad de la bomba.
Operating modes Modos de operaciónH
Q
H
Q
H
Q
H
max
min
+-
+-
+ -
+-
117
Performance - Prestaciones n ≈ 3450 rpm
27
54
81
107
24,5
49
73,5
98
23,7
47,5
71
94,5
23
46
69
92
22
44
66,5
89
20,5
41,5
63,5
84,5
19
38,5
60
80
17,5
35
55
73,5
15
29
47,5
64,5
MXH 3201-60/B
MXH 3202-60/A
MXH 3203-60/B
MXH 3204-60/A
kW
4
7,5
11
15
HP
5,5
10
15
20
Qm /h
l/min
H m
3
3 ~ P2
633500
0
0
18
300
22
366
26
433
30 34
566
38 42
700
47
783
11
23
37,5
52
52
866
29,5
59
88,5
25,5
51
76,5
24,5
49
73,5
23
46
68,5
21
42,5
63,5
20
40,5
61
17,5
36,5
54,5
15
32
47,5
13
27,5
40,5
MXH 4801-60/B
MXH 4802-60/B
MXH 4803-60/A
kW
4
9,2
15
HP
5,5
12,5
20
Qm /h
l/min
H m
3
3 ~ P2
900750
0
0
27
450
33
550
39
650
45 48
800
54 60
1000
65
1083
10,5
23,5
34,5
70
1166
MXH 2001-60
MXH 2002-60
MXH 2003-60
MXH 2004-60
Qm /h
l/min
Hm
33 ~ P2
25,3
51,9
78
103,5
22,7
47
71,5
95
21,8
45,3
69
91,5
20
42,4
65
86
18,8
40,4
62,5
82,5
17,4
38
59
78
15,7
35,1
54,5
72,5
12,4
29,6
45,5
62
300233
0
0
9
150
12
200
21
44
67
89
14 16
266
18 20
333
22
366
25
416kW
1,5
3
5,5
7,5
HP
2
4
7,5
10
MXH 20,32,48 60 Hz
Test results with clean cold water, without gas content.Resultados de las pruebas con agua fría y limpia, sin gas.
Rated currents - Intensidades nominales
P2 Rated motor power output.Potencia nominal del motor.
IA/IN D.O.L. starting current / Rated currentIntensidad de arranque / Intensidad nominal
1,534
5,57,59,21115
kW
24
5,57,510
12,515
18,5
7,4/4,313,4/7,7
HP IN A220/380V
three-phase - trifásico3~
--
11,2/6,513,7/7,917/9,8
22/12,725,8/14,933,2/19,2
IN A380/660V
7,8/4,514,0/8,1
IN A220/440V
7,38,49,28,79,28,38,99,4
IA/IN
P2 Rated motor power output.Potencia nominal del motor.
+ 0,5 m security margin on NPSH-value is necessary.
Para el valor del NPSH se recomienda un margen de seguridad de + 0,5 m.
Tolerances according to UNI EN ISO 9906:2012.Tolerancias según UNI EN ISO 9906:2012.
118
72.1035
ftm
m /h
l/min
ft
Pst
kWPst
m /h
NPSH
m
H
Q
Q
3
3
η
%η5
6
0
2
4
2
60
70
40
1000
200 250
50
6010 30
10 30
ft
50
60
70
70
104
6
040200
50
30
800600400200
Imp. g.p.m. 15010050
200
100
04020
60
70
80
90
40
20
30
10
0
0
3
0
0
72.9743
3
H
Q
Q
0 50
0
3
4
5
0
0
20
40
60
80
90
100
110
10
30
70
10 20 30 400
100
200
50 100 150Imp. g.p.m.
ft
m
200 400 600 800300 500 700
m /h
l/min
30
70
50
η
PstkW
Pst%
η
1
10
0 5010 20 30 40m /h0
4
NPSH
ft
m
0
20
8
300
200
900
72.9743
3
Q
Q
0 25
0
1
2
0
0
20
40
60
110
100
80
10
30
70
5 10 15 200
100
200
25 50 75U.S. g.p.m.
ft
100 200 300 400
m /h
l/min
40
80
60
η Pst
kW
Pst
%
η
0
10
0 5 10 15 20 25m /h0
4
NPSH
ft
m
0
20
8
90 300
100
Hm
MXH 3203-60
MXH 3204-60
MXH 3202-60
MXH 3201-60
MXH 4803-60
MXH 4802-60
MXH 4801-60
MXH 2003-60
MXH 2004-60
MXH 2002-60
MXH 2001-60
Characteristic curves - Curvas Características n ≈ 3450 rpm
MXH EI 2001-60MXH EI 2002-60MXH EI 2003-60MXH EI 2004-60MXH EI 3201-60/BMXH EI 3202-60/AMXH EI 3203-60/BMXH EI 3204-60/AMXH EI 4801-60/BMXH EI 4802-60/BMXH EI 4803-60/A
FlexibilityTwo versions of ports: threaded and flanged.
Extra safetyWith front axis suction port for optimum suction conditions.
ReliableAll hydraulic parts in contact with the pumped liquid are madein stainless steel. For liquids from -15 °C to 110 °C.
RobustSingle-piece, thick barrel casing, open on one side only, withreinforced threaded ports.
CompactThe bracket between pump and motor is extremely compact.
Greater protectionAgainst leakage, with the pump casing cover separated fromthe motor shield. Possibility of inspecting the seal through the side aperturesbetween the two walls.
MXH 20,32,48 60 Hz
FlexibleDiferentes versiones de orificios: roscados y con brida.
Más seguridadCon la boca de aspiración frontal para una mejor capacidadde aspiración.
FiableTodas las partes hidráulicas en contacto con el líquido son deacero inoxidable. Para líquidos de -15 °C a +110 °C.
RobustaCuerpo bomba de una sola pieza de grueso espesor, abiertopor un solo lado, manguitos de aspiración y impulsión renfor-zados.
CompactaAcoplamiento bomba motor muy compacto.
Mayor protecciónContra las pérdidas del cierre, con la tapa de la bomba sepa-rada de la tapa del motor. Posibilidad de inspección del sello mecánico a través de laabertura lateral entre las dos paredes.