This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Analytically Accurate® Technology
Preserve Sample Integrity Offset Joule-Thomson Cooling API 14.1 Compliancy ISO 8943, CSA, & CRN Approvals Class 1, Group D, Div 1 Location
Enclosures Compact & Modular Systems Custom Engineering & Design
Mustang Sampling®
Product Catalog
Natural Gas | LNG | NGL | BIOGAS
Analytically Accurate® Technology
Maximum Heat Trace Tubing Lengths Per Circuit Breaker Sizes (in feet)
Our patented power connection design utilizes existing heat trace tubing powered without additional power or natural gas for proper operations and conforms to API 14.1. This Analytically Accurate® technology is a standard among many companies and utilized with multiple Mustang Sampling® products
Sample Conditioning & Control
Analytically Accurate® Technology
■ Utilizes existing heat trace tubing for power ■ Conforms to API 14.1 guidelines by removing sample at line conditions and maintaining heat 30
F above hydrocarbon dewpoint
■ Heated, insulated, weather-proof enclosures ■ Reduces installation & maintenance ■ Used with multiple Mustang Sampling® products such as the Mustang® P53, Pony® Probe En-
closure, Heated Regulators, MPRVSS, and the Mustang Intelligent Vaporizer Sample Conditioning System®
Along with the MSCS (Mustang® P53 Sampling Conditioning System with Pony® Probe
Enclosure), our Analytically Accurate®
patented power connection design is a standard among many companies and utilized with multiple Mustang
Sampling® products
Patented Power Connection
Sample Conditioning & Control
Mustang® P53 Sample Conditioning System (MSCS)
► cETLus Certified
► Patented technology delivers a heated sample to the analytical device utilizing
existing power supplied by heat trace sample tubing
► Ensures optimal performance of gas analyzers
► Maintains gas at least 30°F above the expected hydrocarbon dew point.
► Rated for Class 1, Group D, Div 1 locations
MODEL: P53 Remote, P53 Direct, Pony SCS, Custom designs within other enclosures
Pony® Probe Enclosure
► cETLus Certified
► Patented technology maintains heat at the sample point
► Ensures optimal performance of gas analyzers
► Maintains gas at least 30°F above the expected hydrocarbon dew point.
► Rated for Class 1, Group D, Div 1 locations
MODEL: PONY, Pony SCS, Solar Powered Pony SCS, Certicollar® adaptors for use with
multiple probe styles including the Mustang Certiprobe® Sample Extractor
Sample Conditioning Systems (SCS)
Mustang® Portable Sampling System—MHR
► Utilizes the Mustang® Heated Regulator
► Analysis at sample point
► Compact and portable
► Low power requirement
► Powered from truck inverter
► Preserves sample integrity from extraction point to analyzer
► 2 model options depending on your regulation needs
MODELS: MPHSS1
Mustang® Portable Sampling Systems—MJTHR
► Utilizes the Mustang® Joule Thomson Heated Regulator
► Analysis at sample point
► Compact and portable
► Low power requirement
► Powered from truck inverter
► Preserves sample integrity from extraction point to analyzer
► 2 model options depending on your regulation needs
MODELS: MPHSS2
Solar Powered Sample Conditioning System
► Patented technology maintains heat at the sample point
► Low Power Consumption
► Integral Sample Conditioning
► Minimum 5 days autonomy (runtime with no sun)
► Rated for Class I, Div I locations
Mustang® Bio-Gas Sample Conditioning System
► Conditions landfill or digester gas samples for green energy
► Maintains representative sample of low pressure feed gas
► Ensures optimal performance of gas analyzers
► Maintains gas at least 30°F above the expected
hydrocarbon dew point.
► Rated for Class 1, Group D, Div 1 locations
MODEL: MBGSCS for use with Pony® Probe Enclosures
Mustang® Regulators
► ATEX/IECEx & cETLus Certified
► CRN Approved
► MHR provides efficient heat transfer through pre-heat and post-heat chambers &
proportional temperature control
► MJTR offsets Joule-Thomson cooling
► High pressure options allow for higher inlet pressures
► Equations of State Phase Diagram determines heated and supercritical application
needs
MODEL: MR, MHR, MHR-I
Mustang® Joule-Thomson Regulators
► ATEX/IECEx & cETLus Certified
► CRN Approved
► MHR provides efficient heat transfer through pre-heat and post-heat chambers &
proportional temperature control
► MJTR offsets Joule-Thomson cooling
► High pressure options allow for higher inlet pressures
► Equations of State Phase Diagram determines heated and supercritical application
needs
MODEL: MJTR, MJTHR, MJTHR-I
Sample Regulation & Control
Mustang® Modular Analyzer Distribution Panel
► Modular design securely fits inside a heated cabinet with easy maintenance
► Single inlet pressure delivers to 4 locations
► Individually isolated outlet pressure
MODEL: MMADP, MMADPE w/ Enclosure for use in non-heated areas, Custom designs
within other enclosures
Mustang® Modular Sample Control Panels
► Class I Div I Enclosures
► Panel replacement w/o disconnecting tubing
► Direct replacement for new and existing analyzers
► API 14.1 Compliance
► Modular construction w/ field interchangeable parts and pieces
MODEL: MMSCP
Mustang® Moisture Analyzer System
► All-in-One Design with MSCS and Moisture Analyzer
► Patented technology delivers a heated sample to the analytical device utilizing
existing power supplied by heat trace sample tubing
► Ensures optimal performance of moisture analyzer
► Maintains gas at least 30°F above the expected hydrocarbon dew point.
► Rated for Class 1, Group D, Div 1 locations
► Modular construction w/ field interchangeable parts and pieces
MODEL: MMAS, Other Analyzer Enclosures Available
Mustang Certiprobe® Sample Extractor
► Conforms to ASME B 31.3-2014 & ISO 8943-2007
► Includes NDE; Dye Penetrant (PT), Hydrotest, and PMI (if requested)
► Fabricated to customer-specified metallurgy & rating
► Stress analysis as part of design process
► Suitable for LNG, LPG, & other process sampling
► Can be utilized with the Pony® Probe Enclosure
► Custom ANSI rating and length
MODEL: MCP
Mustang® Pressure Regulating Vaporizer Sampling System
► ATEX/IECEx Certified
► cETLus Certified
► Conforms to ASME B 31.3-2014 & ISO 8943-2007
► Includes NDE of PMI and DPI
► Fabricated to customer-specified metallurgy & rating
► Stress analysis prior to pipeline installation
► Suitable for LNG, LPG, & other process sampling
► Can be utilized with the Pony® Probe Enclosure
► Custom ANSI rating and length
MODEL: MV, MV-I
Mustang® Vacuum Jacketed Tubing
► Designed to ASME B31.3 for Pressure Piping
► Rigid or Flexible Tubing Options
► Prevents Pre-Vaporization
► Multi-layered insulation
► More efficient than conventional insulated lines
History of Sample Conditioning and Control The measurement and control industry has always had accuracy at the top of their priority list and we have been simplifying the process for many years. When we moved into the sampling aspect of our company, we began the design process that would become the foundation for many products to come. The Mustang® Sample Conditioning System was developed in 2004. A letter was sent out to the employees with a $100 award for the person that could come up with the perfect name for the system. Owners Ken & Brenda loved horses and Engineer, Walt, was passionate about the P51 Mustang fighter plane. With the fierce and reliant history of these images, the direct mount MSCS was named the P51 Mustang® Sample Conditioning System. The remote mount was titled the Pony® Heated Probe Enclosure. The first design was housed in a stainless steel box with heat tracing wrapped inside to keep the sample warm, and offset Joule-Thomson cooling (which results in inaccurate measurement). As the design progressed, heaters were used within the enclosures, but the patented design was still powered with the heat tracing used to power the box, eliminating the need for costly services to run rigid conduit to the sample point. In 2004, the initial design was finalized and taken to Dominion’s cold box testing facility in Clarksburg, WV. The sample was setup to take a large pressure drop within an environment ranging from -30 deg. F to 100 deg. F, which would be prime conditions for Joule-Thomson cooling and result in an accurate sample. Valtronics and Dominion left for dinner and then slept on it, and when they returned the next day (over 12 hours in the testing conditions), the sample held it’s temperature. To further prove the design, the MSCS was taken to the El Paso Corporation cold box in Houston, TX and passed that test with flying colors as well. In 2015, Mustang Sampling® became the main sponsor for the Action Express Racing No. 5 Chevrolet Corvette ( now the 2014-15 defending champion of the IMSA WeatherTech United SportsCar Championship) extending its global outreach through a sport near to many in the Oil & Gas industry. Growing up watching his father race in NASCAR, Ken has had a long history of passion for high quality machines built with innovation in mind—a force that drives Mustang Sampling® to constantly produce efficient solutions that work seamlessly for our customers.
Mustang Sampling® was developed as a sister-company to Valtronics and continues to develop and provide Analytically Accurate® products for measurement and control.