For continual product development, LG
reserves the right to change specifications without notice.
** Conditional Application To make 40~90m of pipe length after first branch, refer to the part of “installation of outdoor units” in PDB
1000m
150m(200m**)
40m[90m**]
100m
15m
5m
Totalpipinglength
Longestpipinglength
Longestpipinglengthafter1stbranch
LeveldifferencebetweenODU~IDU
LeveldifferencebetweenIDU~IDU
LeveldifferencebetweenODU~ODU
05
06
01
04
03
02
LG A
ir Conditioners System
14_
15O
utdoor Unit_
MU
LTI V series
Enhanced comfort for end-user!
* Based on MULTI V PLUS II, 10HP model
Night Silent OperationNight silent operation will be on for X hours starting from the peak temperature during daytime, and then after Y hours, it’ll be back to normal operation. - Mode 1 > X : 8.0 hours, Y : 9.0 hours - Mode 2 > X : 6.5 hours, Y : 10.5 hours - Mode 3 > X : 5.0 hours, Y : 12.0 hours
Each mode can be selected as 3 steps of sound level.
LG MV • Easy start-up, easy trouble shooting
• Monitoring the normality of all parts such as compressor, fan, valve, etc
• Operation state • Central Controller • Cycle view
Command
Sensor reading
LATS MULTI V • Convenient model selection program
• Highly user-friendly design (Autocad version)
• Automatic piping design & check
Download from sales supporting system> http://www.lgeaircon.com
• Model selection • Auto check
• CAD application • Making quotation
Pursuing the market needs of high energy efficiency and environmental friendliness.
Outdoor unit
Unit : dBA
MINI PLUS II SYNC IIStep 1Step 2Step 3
46
43
40
47
44
41
47
44
41
MULTI V MINI / MULTI V PLUS II MULTI V SYNC II / MULTI V SPACE II
2009 New Features
Automatic Refrigerant Charging• Refrigerant charging without any scales or quantity calculation
• This function is recommended during service.
• Guaranteed temperature range : IDU(20~32˚C), ODU(0~43˚C)
• FDD function (Fault detect & diagnosis)
Manifold
Refrigerant charging kit
Refrigerant
* Fault detect & diagnosis
Automatic Refrigerant Check-Up• It can be checked refrigerant status during start-up whether it is undercharged or overcharged
• It can be decided appropriate amount of refrigerant automatically through cycle operation.
• FDD function (Fault detect & diagnosis)
Leakage!
Leakage!
Leakage!
Leakage!
* Fault detect & diagnosis
LG A
ir Conditioners System
16_
17O
utdoor Unit_
MU
LTI V MIN
I
EFFICIENCYMULTI V MINI uses the cutting-edge, artificial intelligence control to obtain efficient operation and reduced noise.
MULTI V MINI can be easily installed in small offices
and shops. Designed for low-noise operation,
it ensures a pleasant air conditioned environment.
Enjoy a clean & comfortable life with MULTI V MINI.
Day time Night time(Based on 4HP)
• Noise level (dBA)
Slim & Compact SizeEasy & efficient installation of MULTI V MINI will provide the best solution for small offices and shops.
4, 5, 6 HP5, 6 HP
• Foot print area
806mm
730mm
330mm
950mm
46%Reduction
• Volume
52%Reduction
WxHxD : 806×1607×730 WxHxD : 950x1380x330
Conventional
50 51 52
4HP 5HP 6HP STEP 1 STEP 2 STEP 3
404346
Enhanced Comfort• Night silent operation
• High COP
• Longest Piping Length
Cooling Heating Cooling Heating
4HP5HP6HP
1Ø, 220V 3Ø, 380V
3.93.73.6
4.04.03.8
3.73.63.5
3.93.93.8
Total piping length
Longest piping length (Equivalent)
Longest piping length after 1st branch
Level difference between ODU~IDU
Level difference between IDU~IDU
Level difference between ODU~ODU
300m
150m(175m)
40m
50m(40m*)
15m
5m
*Outdoor unit is lower than indoor unit.
11.212.52.93.1
3.864.03
950 x 1380 x 330118
5052
110
1
3.7
FV50S[PVE] 1.7
Ø9.52(3/8)Ø15.88(5/8)
16
15.518.04.34.7
3.603.83
950 x 1380 x 330118
5254
110 1
3.7
FV50S[PVE] 1.7
Ø9.52(3/8)Ø19.05(3/4)
19
14.016.03.84.0
3.684.00
1, 220 ~ 240, 50950 x 1380 x 330
118
5153
110 1
3.7
FV50S[PVE] 1.7
Ø9.52(3/8)Ø15.88(5/8)
18
LG A
ir Conditioners System
18_
19O
utdoor Unit_
MU
LTI V MIN
I
Max. 9 Indoor Units ConnectableMaximum 9 indoor units can be connected to one single outdoor unit with 130% indoor unit combination.
- 9 indoor units for 6HP - 8 indoor units for 5HP - 6 indoor units for 4HP
Easy to Service
Inner SVC valve- 4 Way piping is possible (Front, Rear, Right, Down)
- Excellent exterior
01
Convenient moving handle02
units
*Based on 6 HP model
54321
876 9
1 Way 4 Way
Compact design & Easy service- Remove 3 pieces of screw for SVC- Front panel removal system
03
• DC Inverter Compressor & Fan motor
• Black Box Function
• Night Silent Operation
• Fault Detect & Diagnosis
• Pump Down
‘09 New Feature
3 pieces of screw
Easy service
MULTI V MINI can be easily installed in small offices
and shops. Designed for low-noise operation,
it ensures a pleasant air conditioned environment.
* Specifications
Capacity Cooling kW Heating kWPower Cooling kWInput Heating kWCOP Cooling HeatingPower Supply Ø, V, HzDimensions(WxHxD) mmWeight kgColorNoise level Cooling dBA±3 Heating dBA±3Fan Type Air flow rate [CMM]Compressor Type Number of compressorsHeat ExchangerRefrigerant Type Charge kg ControlRefrigerant TypeOil Charge lPiping Liquid Pipes mm(inch)Connections Gas Pipes mm(inch)Number of outdoor unitNumber of maximum connectable indoor units
HP
Model 4
Ratio of the connectable indoor unitsLongest piping length / Level difference
65
EEV
Gold FinR410A
DC INVERTER
BLDC
Warm Gray
5 64
14.016.03.94.1
3.593.90
3, 380 ~ 415, 50950 x 1380 x 330
112
5153
110 1
3.7
FV50S[PVE] 1.3
Ø9.52(3/8)Ø15.88(5/8)
18
11.212.53.03.2
3.733.91
950 x 1380 x 330
112
5052
110
1
3.7
FV50S[PVE] 1.3
Ø9.52(3/8)Ø15.88(5/8)
16
15.518.0 4.44.8
3.523.75
950 x 1380 x 330
112
52 54
110 1
3.7
FV50S[PVE] 1.3
Ø9.52(3/8)Ø19.05(3/4)
19
EEV
Gold FinR410A
DC INVERTER
BLDC
Warm Gray
Independent Unit ARUN40GS2 ARUN60GS2ARUN50GS2 ARUN40LS2 ARUN60LS2ARUN50LS2
*1Ø, 220V *3Ø, 380V
150m/50m50~130%
150m/50m50~130%
Note :
1. Capacities are based on the following conditions Cooling-Indoor temp. 27°C[80.6°F]DB / 19°C[66.2°F]WB Heating-Indoor temp. 20°C[68°F]DB / 15°C[59°F]WB
Outdoor temp. 35°C[95°F]DB / 24°C[75.2°F]WB Outdoor temp. 7°C[44.6°F]DB / 6°C[42.8°F]WBInterconnecting piping length 7.5m Interconnecting piping length 7.5mLevel difference of zero Level difference of zero
2. Capacities are net capacities3. Due to our policy of innovation some specifications may be changed without notification4. EEV : Electronic Expansion Valve
CONVENIENCEFrom installation and transportation to maintenance and service, MULTI V PLUS II adds convenience to cutting-edge technology.
• Pump down
Refrigerant flow
Repair! Repair! Repair!
• Pump out
Refrigerant flow
Reftigerant flow
Failed!
Pump Down & Pump Out• Pump down When indoor units need to replace, refrigerant can be collected to the outdoor unit. - MULTI V MINI / PLUS II / SYNC II / SPACE II
• Pump out If left outdoor unit breakdown, refrigerant can be sent to another outdoor and indoor unit during service. - MULTI V PLUS II / SYNC II
Auto addressingAddressing outdoor units and indoor units are automatically done just by pressing the button.
Automatic Back-Up• For emergency, it makes back-up operation possible before trouble-shooting
Inverter A, B + Constant B > Inverter B + Constant A, B
• Error notice in indoor unit : 4 times per day (every 6 hour)
Plate Type SC HEX• Increased sub-cooling by high- performance heat exchanger
• Enable to be long piping length and level difference
• More powerful cooling operation
Double tube
Plate SC
Non-Polarity Transmission ConnectionEasy installation and no errors for transmission line connections
* Combination possible model only
Wired remote control
Wired remote control
Wired remote control
Indoor unit Indoor unit Indoor unit
Cool / Heat Selector• Control all units without any central controller installed
Weight kgColorNoiselevel dBA±3Fan Type Airflowrate [CMM]Compressor Type NumberofcompressorsHeatExchangerRefrigerant Type Charge kg ControlRefrigerant TypeOil Charge lPiping LiquidPipes mm(inch)Connections GasPipes mm(inch)NumberofoutdoorunitNumberofmaximumconnectableindoorunits*
Weight kgColorNoiselevel dBA±3Fan Type Airflowrate [CMM]Compressor Type NumberofcompressorsHeatExchangerRefrigerant Type Charge kg ControlRefrigerant TypeOil Charge lPiping LiquidPipes mm(inch)Connections GasPipes mm(inch)NumberofoutdoorunitNumberofmaximumconnectableindoorunits
• A combination operation over 100% cause to reduce each indoor unit capacity
•Combinationratio(50~200%)
No. of outdoor unit Connection CapacitySingle unit 200%Double unit 160%Triple unit 130%Over triple unit 130%
CAUTION
We can guarantee the operation only within 130% Combination.If you want to connect more than 130% combination, please contact us and discuss the requirement like below.
1) If the operation of indoor unit is more than 130%, low airflow operation is recommended in all the indoor units. 2) If the operation of indoor unit is more than 130%, additional refrigerant is needed according to the headquarter guidance. 3) Over 130%, capacity is same as capacity of 130%, Same remark is valid for power input.
• A combination operation over 100% cause to reduce each indoor unit capacity
• Combinationratio(50~200%)No. of outdoor unit Connection CapacitySingle unit 200%Double unit 160%Triple unit 130%
CAUTION We can guarantee the operation only within 130% Combination.If you want to connect more than 130% combination, please contact us and discuss the requirement like below.
1) If the operation of indoor unit is more than 130%, low airflow operation is recommended in all the indoor units. 2) If the operation of indoor unit is more than 130%, additional refrigerant is needed according to the headquarter guidance. 3) Over 130%, capacity is same as capacity of 130%, Same remark is valid for power input.
1. Capacities are based on the following conditions Cooling-Indoor temp. 27°C[80.6°F]DB / 19°C[66.2°F]WB Heating-Indoor temp. 20°C[68°F]DB / 15°C[59°F]WB
Outdoor temp. 35°C[95°F]DB / 24°C[75.2°F]WB Outdoor temp. 7°C[44.6°F]DB / 6°C[42.8°F]WBInterconnecting piping length 7.5m Interconnecting piping length 7.5mLevel difference of zero Level difference of zero
2. Capacities are net capacities3. Due to our policy of innovation some specifications may be changed without notification4. EEV : Electronic Expansion Valve
1stepsLouver frame
4stepsFan parts
3stepsMechanical parts
2stepsSystem louver
4-Step Modularized Design• Modularized design of the outdoor unit provides simpler installation and maintenance.
• Outdoor unit can be installed according to overall building construction schedule.
• Louver is provided locally
Discharging
Duct
Duct application Fan RPM Control (E.S.P & Noise Control)
SPACE II is ideal for refined and luxurious living
spaces.
HPModel Independent unit Capacity Cooling kW Heating kWPower Cooling kWInput Heating kWCOP Cooling kW Heating kWPower Supply Ø, V, HzDimensions(WxHxD) mmWeight kgColorNoise level dBA±3E.S.P range mmAqFan Type Air flow rate [CMM]Compressor Type Number of compressorsHeat ExchangerRefrigerant Type Charge kg ControlRefrigerant TypeOil Charge lPiping Liquid(flare) mm(inch)Connections Gas(Bazing) mm(inch)Number of outdoor unitNumber of maximum connectable indoor unitsRatio of the connectable indoor unitsLongest piping length / Level difference
16.0
18.0
4.7
4.9
3.40
3.67
3, 380~415, 50
750 x 1790 x 650
200
49
4~12
100
1
5.2
2.3
9.52(3/8)
19.05(3/4)
1
9
* Specifications
6
21.7
23.0
6.7
6.7
3.24
3.43
3, 380~415, 50
750 x 1790 x 650
200
53
4~12
100
1
5.2
2.3
9.52(3/8)
19.05(3/4)
1
13
8ARUN60LR2 (Right Discharge)
ARUN60LL2 (Left Discharge)
ARUN80LR2 (Right Discharge)
ARUN80LL2 (Left Discharge)
Warm Gray
Sirocco Fan
DC INV Scroll
Gold Fin
R410A
EEV
FVC68D(PVE)
50~130%
150m/50m
* Preliminary data (8HP model)
LG A
ir Conditioners System
38_
39Indoor U
nit
Wall mounted
ARTCOOL
Ceiling Cassette
Ceiling Concealed Duct
Ceiling & Floor
Ceiling Suspended
Floor standing
49505256606162
M U LT I V i n d o o r
If you need a highly efficient air conditioning system in your building, MULTI V is the right choice for you.
Indoor unit
Wall Mounted
Mirror
4Way Casstte
2Way Casstte
1Way Casstte
Low Static
Built-in
High Static
Ceiling & Floor
Ceiling Suspended
Floor Standing- With Case
Floor Standing- Without Case
LG A
ir Conditioners System
40
_4
1Indoor U
nit
Aesthetic DesignYou no longer have to be told what your air conditioner should look like. With LG’s revolutionary ARTCOOL photo changeable, you can simply change the look of your air conditioner to what you want, when you want to.
ARTCOOL series with outstanding designs have received International Forum Design Award,
Reddot Design Award and G Mark.
Silver 07/09/12GSFV2 Gold 07/09/12GSFG2 Red 07/09/12GSFE2
Low NoiseSuper light BLDC motor guarantees your enhanced comfortable indoor environment.
Typing Office Conversation Library 4 way CST
- How to change the picture
- Panel type
- ARTCOOL Mirror
Auto Elevation GrilleEasy filter cleaning with elevation grille
- Installed inside main body- Auto horizontal level- 4 points support- Memory for user’s level- Max. 4.5m length
4 Way4.5m
Conventional3.5m
4-Point support structure Auto horizontal control
STOP
Memory
Memory for user’s level Auto bottom detection
Max
. 4.5
mSilver 07/09/12/15GSEV2 18/24GS8V2
Mirror 07/09/12/15GSER2 18/24GS8R2
Blue 07/09/12/15GSEB2 18/24GS8B2
• Aesthetic Design
• Low Noise
• 4 Vane Independent Operation
• Auto Elevation Grille
LG has been able to create a design conscious indoor unit that compliments any interior decoration. And they have improved air flow innovatively to realize world’s lowest noise, and provide a more pleasant and convenient indoor environment.
White silver 07/09/12GSFH2
4 Vanes Independent OperationVane angle control satisfies both users who like direct wind and indirect wind. and also it prevents cold air draft.
1 Vane, 1 Motor
1 : 20 °
0 : 30 °
2 : 40 °
3 : 50 ° 4 : 60 °5 : 70 °
All vane operation Individual vane operation
Air flow rate control Individual vane angel control
• Easy vane angle control with a remote controller
Direct air flow Indirect air flow
*Available for 24k ~ 48k Btu/h
LG A
ir Conditioners System
42_
43
Indoor Unit
High Ceiling ModeHigh ceiling mode with phase-control algorithm is possible to apply as high as 3.6m of ceiling.
4 way CSTConventional
Wide Jet VaneImproved wide and narrow vane will provide comfortable temperature distribution withoutair flow dead zone.
80mm Wider!! 567mm
487mm
NEW
Current
Even air distributiont262524232221201918
27°CTemp.
15°C
Highlander
Air flow dead zonet262524232221201918
27°CTemp.
15°C
Current
• Air flow improvement
Flexible ConnectionFlexible connection of remote controller
- Group control : 1 remote controller to several indoor units
- Second remote control : 2 remote controllers to 1 indoor unit
Easy & solid attachment to the wall wall
wall
Application of Ceiling Concealed DuctIt is possible to make each rooms cool & warm with installing a chamber and a spiral duct.
Max. 9 discharging
Linear E.S.P ControlAir volume and sound are always kept as design regardless of E.S.P changeusing this technology , you can
• Optimize duct work Installation• Keep capacity & sound level as desired• Simplify model numbers
The phase control motor technology offers money saving benefit to the installer.
*E.S.P is easily controlled by remote controller
Application of Built-in DuctBuilt-in duct has no need of duct space with using suction canvas and grille.
CanvasGrille
• Wide Jet Vane
• High Ceiling Mode
• Flexible Connection
• Appliaction of Ceiling Concealed Duct
• Appliaction of Built-in Duct
• Linear E.S.P Control
LG has been able to create a design conscious indoor unit that compliments any interior decoration. And they have improved air flow innovatively to realize world’s lowest noise, and provide a more pleasant and convenient indoor environment.
* For 4 way cassette (570 * 570), this function will be applied from May.
LG A
ir Conditioners System
44
_4
5Indoor U
nit
Drain hose Drain pump
One Touch Type PanelIt provides easy installation with a one-touch detachable panel.
Compact SizeThe indoor unit with slim and compact size has reduced the restriction which enables successful installation in various spaces.
LG conventional
204mm
218mm
246mm
288mm
6.0 ~ 7.2 kW 8.3 ~ 11.0 kW
Back
Side Floor
Sliding Type FilterEasy maintenance and extended product life with sliding type anti-biotic filter.
Sliding type
Anti-biotic filter Easy cleaning
Convenient InstallationEasy installation with corner detachable decoration panel.
• Coner detachable design
Drain leakage check
Refrigerantpiping check
Hanger adjust Hanger adjust
• Compact Size
• One Touch Type Panel
• Convenient Installation
• Easy Drain Installation
• 3Way Flexible Installation
• Sliding Type Filter
LG has been able to create a design conscious indoor unit that compliments any interior decoration. And they have improved air flow innovatively to realize world’s lowest noise, and provide a more pleasant and convenient indoor environment.
Drain leakage check Hanger adjust
Easy Drain InstallationIt reduces the installation time by over 40% with elbow-less drain hose.
Digital Air Flow ControlThe air flow can be controlled to ensure maximum comfort and convenience.
Normal fast & even widely
Jet cool speedy & powerful
Sleep mode indirectly & softly
Neo Plasma Air Purifying SystemLG’s unique NEO Plasma air purifying system is equipped with 7 specialized filters in 5 separate stages to enhance its cleaning power. It reduces fine dust and mold, unpleasant odors and cigarette smoke as air passes through each filter.
Swirl SwingSwirl swing distributes air evenly throughout the room to ensure a more comfortable conditioned environment by adjusting the movement of the vane.
Nano Bio Fusion Filter
Nano bio fusion filters allow their nanosize bio enzymes to directly penetrate through cell walls of some bacteria and allergen to decompose its cell nuclei.
* Test Result Certification
Distinctions from Conventional Filters
The bio enzyme destroys cell walls and nuclei of some bacteria and allergens.
• Nano Bio Fusion Filter
• Conventional
Simply inactivatebacteria
Destroy bacteria but allowpart of them to survive
Pre Filter
The antibacterial pre-filter primarily reduces large dust, mold and quilt dust.
01
Nano Carbon Filter
Nano-size carbon filters remove fine odorous particles from the household air resulting in a more pleasant environment.
What is Nano Carbon Ball?Microscopic sized (1/1000000000) filter to ensure optimal filtration of odors.
200~500nm
02
Triple Filter
The triple filter consists of three specialized filters to reduce the symptoms associated with various organic compounds including formaldehyde. It also has the ability to reduce unpleasant odors creating a more comfortable environment.
03
04
Plasma Filter
The PLASMA Air Purifying System developed uniquely by LG not only reduces microscopic contaminants and dust, but also reduces house mites, pollen, and pet fur to reduce allergy and asthma symptoms.
05
Bio Active Site
NanoParticle
Active State Bacteria Selective Capture
Bacteriolysis Regeneration(Active State)
NanoParticle
NanoParticle
NanoParticle
Bacteria, Virus
Clean AirPolluted Air
01 02 03 04 05
Odor Free! Dust Free! Allergy Free!
LG has been able to create a design conscious indoor unit that compliments any interior decoration. And they have improved air flow innovatively to realize world’s lowest noise, and provide a more pleasant and convenient indoor environment.
• Neo Plasma Air Purifying System
• Digital Air Flow Control
• Swirl Swing
• Child Lock Function
Healthy DehumidificationDehumidification mode reducesuncomfortable humidity from theroom without over cooling.
LG Healthy DehumidificationBy increasing the vane angle, a better approach of the actual temperature is possible to prevent over cooling.
ConventionalSince the surrounding temperature is measured after the air from the unit is widely distributed, accurate approach of the air is not possible.
Indoor Temperature Distribution Chart
LG A
ir Conditioners System
48
_4
9Indoor U
nit
Weekly ProgramThe operator can set an on/off reservation of the air conditioner for a period of one week.
LCD Wired Remote Controller• On/Off• Test run mode• Self-diagnosis• 3-step fan speed selection• Operation indication• Room temperature
Auto CleanAuto clean helps to remove odor and save clean-up time. After using airconditioner, “Auto clean” makes the inner part of Air conditioner dry for 30 min. It removes mositure and mold so you can enjoy odor-free air and save time to clean up.
LG Auto Clean Conventional
Dries the evaporator with gentle low noise air from the fan by removing any remaining moisture.Pressing the Auto Clean button will activate the automatic cleaning function after the cooling operation.
1 STEP
Removes moulds through the neo plasma system.Only the fan will operate to dry the inner part of the air conditioner in just 30 minutes.
2 STEP
Air Flow Direction ControlHorizontal airflow control- Adjust the horizontal airflow direction by manually moving the horizontal airflow direction vane by hand.
Vertical airflow- The airflow direction can be adjusted as desired by using the remote controller.
Horizontal airflow control Vertical airflow control
LG has been able to create a design conscious indoor unit that compliments any interior decoration. And they have improved air flow innovatively to realize world’s lowest noise, and provide a more pleasant and convenient indoor environment.
1. Capacities are based on the following conditions Cooling-Indoor temp. 27°C[80.6°F]DB / 19°C[66.2°F]WB Heating-Indoor temp. 20°C[68°F]DB / 15°C[59°F]WB Outdoor temp. 35°C[95°F]DB / 24°C[75.2°F]WB Outdoor temp. 7°C[44.6°F]DB / 6°C[42.8°F]WB Interconnecting piping length 7.5m Interconnecting piping length 7.5m Level difference of zero Level difference of zero2. Due to our policy of innovation some specifications may be changed without notification
* For using wireless remote controller, it needs to install standard wired remote controller. (Duct, Floor standing model.)* For using wireless remote controller, it needs to install standard wired remote controller. (Duct, Floor standing model.)
* Check up the note, refer to on the 49 page. * Check up the note, refer to on the 49 page.
* For using wireless remote controller, it needs to install standard wired remote controller. (Duct, Floor standing model.)* For using wireless remote controller, it needs to install standard wired remote controller. (Duct, Floor standing model.)
* Check up the note, refer to on the 49 page. * Check up the note, refer to on the 49 page.
LG A
ir Conditioners System
64
_6
5
Heat Recovery Ventilator
Features
Installation & Maintenance
Line-up
Specifications
62636466
eco V
With today’s concern for a healthy indoor environment, eco V is an integral component of HVAC system. eco V Using in the HVAC system allows contaminants to be removed quickly and effectively from the air-conditioned space.
Heat Recovery Ventilator
LG’s heat recovery ventilation system,
eco V, modulates the temperature and
humidity of incoming fresh air to match
indoor conditions. A balance is achieved
between indoor and outdoor ambient,
enabling the cooling or heating load
placed on the air conditioning system to
be reduced significantly.
(Heat Recovery ventilator)
(Heat Recovery ventilator)
LG A
ir Conditioners System
66
_6
7
Easy Cleaning and Changing FilterDoor attached side panel and slide removable Enthalpy heat exchanger filter can be changed without additional maintenance.
• Eco V unit
Top
Low
Low
Top
Reverse installationof 1 unit (Left unit)
Normal installationof 2 units
Flexibility of InstallationIt’s possible to install the opposite direction of upper and lower part. It needs the only one inspection hole.
• Inspection hole
Air Filter Air Filter
Strong Filter FunctionAir filterThe air filter has collection efficiency above 80%, which means it can filter particles up to 0.3 m including tobacco of smoke and even floating particles from yellow sand.
HEPA + Deodorization filter (accessory)The indoor air can be always kept fresh through these filters.
Yellow Sand filter (accessory)This filter can make more comfortable and fresh environment through removing harmful to health 5~20µm sandy dust over 99%.
Features • High Efficiency Heat Exchanger • Bypass Ventilation • Strong Filter Function
High Efficiency Heat ExchangerEfficiency and comfort is ensured by the high-efficiency energy recovery central core which recovers energy from the indoor air and transfers it to the fresh incoming air without mixing airstream.
Exhaust air
Outdoor air (Option) Deodorization filter
Supply air
Indoor airHigh performance filter{
Bypass VentilationIt switches automatically the ventilation mode (Enthalpy Heat Exchange Mode / Bypass Mode) according to the indoor/outdoor temperature.
• Remove heat exchanger• Remove free filter
Damper Damper
• Enthalpy Heat Exchange Mode
• Bypass Mode
[Summer / Winter] [A change of season]
LG A
ir Conditioners System
68
_6
9 (H
eat Recovery ventilator)
The LG heat recovery ventilation system, eco V
is the solution for improving your indoor air quality.
eco V ensures the fresh enviroment in your life!Heat Recovery Ventilator
* Specifications
LZ-H0106BA0
100(28)
1, 220-240, 50
SUPER-HIGH/HIGH/LOW
0.32/0.3/0.28
68/60/50
100/100/90(59/59/53)
40/35/30(0.16/0.14/0.12)
78/78/80
68/68/70
58/58/60
28/26/20
- / - / -
- / - / -
- / - / -
- / - / -
- / - / -
- / - / -
- / - / -
- / - / -
- / - / -
Crossflow
24(52.91)
590x204x590(23.23x8.03x23.23)
4
Ø100(Ø3.94)
1
Direct-Drive
1
Direct-Drive
2
Cleanable
580x10x113(22.83x0.39x4.45)
LZ-H0156BA0
150(42)
1, 220-240, 50
SUPER-HIGH/HIGH/LOW
0.36/0.36/0.35
83/80/78
150/150/100(42/42/28)
70/55/45(0.28/0.22/0.18)
75/75/79
62/62/69
55/55/59
32/30/22
- / - / -
- / - / -
- / - / -
- / - / -
- / - / -
- / - / -
- / - / -
- / - / -
- / - / -
Crossflow
24(52.91)
590x204x590(23.23x8.03x23.23)
4
Ø100(Ø3.94)
1
Direct-Drive
1
Direct-Drive
2
Cleanable
580x10x113(22.83x0.39x4.45)
LZ-H0256BA0
250(69)
1, 220-240, 50
SUPER-HIGH/HIGH/LOW
0.55/0.5/0.34
130/115/80
250/250/180(69/69/50)
65/50/40(0.26/0.2/0.16)
80/80/85
70/70/78
64/64/68
32/28/21
- / - / -
- / - / -
- / - / -
- / - / -
- / - / -
- / - / -
- / - / -
- / - / -
- / - / -
Crossflow
27(59.51)
596x320x640(23.46x12.60x25.20)
4
Ø150(Ø5.91)
1
Direct-Drive
1
Direct-Drive
2
Cleanable
580x10x175(23.23x0.39x6.89)
LZ-H0356BA0
350(97)
1, 220-240, 50
SUPER-HIGH/HIGH/LOW
1.40/1.33/0.9
205/195/170
350/350/210(97/97/58)
170/88/40(0.68/0.35/0.16)
83/83/87
80/80/85
78/78/83
33/28/23
SUPER-HIGH/HIGH/LOW
1.40/1.33/0.9
205/195/170
350/350/210(97/97/58)
170/88/40(0.68/0.35/0.16)
- / - / -
- / - / -
- / - / -
33/28/23
Crossflow
45(99.20)
988x273x1014(38.9x10.75x39.92)
4
Ø200(Ø7.87)
1
Direct-Drive
1
Direct-Drive
2
Cleanable
855x10x166(33.66x0.39x6.54)
Unit
CMH(L/S)
Ø,V,Hz
-
Amps
W
CMH(L/S)
Pa(in.wg)
%
%
%
dBA
-
Amps
W
CMH(L/S)
Pa(in.wg)
%
%
%
dBA
-
kg(lb)
mm(inch)
EA
mm(inch)
EA
-
EA
-
EA
-
mm(inch)
Step
Current
Power Input
Air Flow
External Static Pressure
Temperature Exchange Efficiency
Enthalpy Exchange Efficiency
Noise Level(Sound Level, 1.5m)
Step
Current
Power Input
Air Flow
External Static Pressure
Temperature Exchange Efficiency
Enthalpy Exchange Efficiency
Noise Level(Sound Level, 1.5m)
Item
Nominal Capacity
Power Supply
Heat Exchanger
Weight
Dimension
Duct work
Supply Air Fan
Exhaust Air Fan
Filters
LZ-H0506BA0
500(139)
1, 220~240, 50
SUPER-HIGH/HIGH/LOW
1.51/1.39/1.06
260/225/200
500/500/320(139/139/89)
150/60/28(0.60/0.24/0.11)
75/75/79
75/75/80
70/70/75
34/32/25
SUPER-HIGH/HIGH/LOW
1.51/1.39/1.06
260/225/200
500/500/320(139/139/89)
150/60/28(0.60/0.24/0.11)
- / - / -
- / - / -
- / - / -
34/32/25
Crossflow
52(114.7)
988x273x1014(38.9x10.75x39.92)
4
Ø200(Ø7.87)
1
Direct-Drive
1
Direct-Drive
2
Cleanable
855x10x166(33.66x0.39x6.54)
Notes:1. eco mode - Enthalpy Heat Recovery Ventilation mode2. Noise level : - The operating conditions are assumed to be standard. - Sound measured at 1.5m below the center the body. - Sound level will vary depending on a range of factors such as the construction(acoustic absorption coefficient) of particular room in which the equipment is installed.
eco
V M
ode
Byp
ass
Mod
e
SH/H/L
SH/H/L
SH/H/L
SH/H/L
SH/H/L
Heating(SH/H/L)
Cooling(SH/H/L)
SH/H/L
SH/H/L
SH/H/L
SH/H/L
SH/H/L
SH/H/L
Heating(SH/H/L)
Cooling(SH/H/L)
SH/H/L
Type
WxHxD
Qty
Size(Ø)
Qty
Type
Qty
Type
Qty
Type
Size(WxHxD)
* Specifications
Unit
CMH(L/S)
Ø,V,Hz
-
Amps
W
CMH(L/S)
Pa(in.wg)
%
%
%
dBA
-
Amps
W
CMH(L/S)
Pa(in.wg)
%
%
%
dBA
-
kg(lb)
mm(inch)
EA
mm(inch)
EA
-
EA
-
EA
-
mm(inch)
Item
Nominal Capacity
Power Supply
Heat Exchanger
Weight
Dimension
Duct work
Supply Air Fan
Exhaust Air Fan
Filters
LZ-H1006BA0
1000(278)
1, 220~240, 50
SUPER-HIGH/HIGH/LOW
3.0/2.9/2.6
560/540/470
1000/1000/800(278/278/222)
160/90/50(0.80/0.44/0.24)
75/75/78
66/66/71
61/61/66
37/35/31
SUPER-HIGH/HIGH/LOW
2.8/2.7/2.4
560/540/470
1000/1000/800(278/278/222)
160/90/50(0.80/0.44/0.24)
- / - / -
- / - / -
- / - / -
37/35/31
Crossflow
67(147.7)
1062x365x1140 (41.9x14.4x44.9)
4
Ø250(Ø9.54)
1
Direct-Drive
1
Direct-Drive
2
Cleanable
1056x10x212.5(41.57x0.39x8.37)
LZ-H1506BA0
1500(417)
1, 220~240, 50
SUPER-HIGH/HIGH/LOW
5.6/5.4/5.2
950/925/795
1500/1500/1200(417/417/333)
200/110/60(0.80/0.44/0.24)
79/79/82
70/70/75
65/65/70
39/37/33
SUPER-HIGH/HIGH/LOW
5.6/5.4/5.2
950/925/795
1500/1500/1200(417/417/333)
200/110/60(0.80/0.44/0.24)
- / - / -
- / - / -
- / - / -
37/35/31
Crossflow
146(321.9)
1313x737x1140(51.7x28.8x44.9)
4+2
Ø250(Ø9.54)+Ø350(Ø13.77)
2
Direct-Drive
2
Direct-Drive
4
Cleanable
1056x10x212.5(41.57x0.39x8.37)
LZ-H2006BA0
2000(556)
1, 220~240, 50
SUPER-HIGH/HIGH/LOW
6.0/5.8/5.2
1020/970/860
2000/2000/1600(556/556/444)
160/90/50(0.80/0.44/0.24)
75/75/78
66/66/71
61/61/66
39/37/33
SUPER-HIGH/HIGH/LOW
5.6/5.4/4.8
1020/970/860
2000/2000/1600(556/556/444)
160/90/50(0.80/0.44/0.24)
- / - / -
- / - / -
- / - / -
37/35/31
Crossflow
146(321.9)
1313x737x1140(51.7x28.8x44.9)
4+2
Ø250(Ø9.54)+Ø350(Ø13.77)
2
Direct-Drive
2
Direct-Drive
4
Cleanable
1056x10x212.5(41.57x0.39x8.37)
LZ-H0806BA0
800(222)
1, 220~240, 50
SUPER-HIGH/HIGH/LOW
2.8/2.7/2.6
405/360/320
800/800/660(222/222/183)
200/110/60(0.80/0.44/0.24)
79/79/82
70/70/75
65/65/70
36/34/30
SUPER-HIGH/HIGH/LOW
2.8/2.7/2.6
405/360/320
800/800/660(222/222/183)
200/110/60(0.80/0.44/0.24)
- / - / -
- / - / -
- / - / -
36/34/30
Crossflow
67(147.7)
1062x365x1140 (41.9x14.4x44.9)
4
Ø250(Ø9.54)
1
Direct-Drive
1
Direct-Drive
2
Cleanable
1056x10x212.5(41.57x0.39x8.37)
Notes:1. eco mode - Enthalpy Heat Recovery Ventilation mode2. Noise level : - The operating conditions are assumed to be standard. - Sound measured at 1.5m below the center the body. - Sound level will vary depending on a range of factors such as the construction(acoustic absorption coefficient) of particular room in which the equipment is installed.
V- n e t & A c c e s s o r yPDI, Remote temperature sensor, Dry contact, Cool/Heat selector, DO KitVentilation Kit (4Way Cassette), AHU Control kit & EEV kit, Refrigerant Charging KitAir guide, Suction grille and canvas, Heat recovery unit, Header, Y branch
Operating modeRoom temperature checkingChaos swing / Jet coolOn_Off timerSleep mode autoMain / Sub setting of indoor units ΔT setting (for Auto Changeover)
* Wired Remote Controller for Air-conditioner
Standard (WIDE)
PQRCUSA1
Features PQRCUSA1
& Accessory
Remote ControllerOur air conditioning system can be controlled by various types of remote controllers providing general control to unique function.
Remote Controller•Wired Remote Controller
•Simple Wired Remote Controller
•Wireless Remote Controller
* Wired Remote Controller for
Standard
Features PZRCUSB0
On / Off LEDVentilation mode settingRapid ventilationPower saving ventilationReservationElectric failure compensationChild lock
Operating modeOn / Off LEDRoom temp.Fan / Plasma / Swirl / HeaterVane control / Auto swing / Fan autoE.S.P functionReservationTimer functionChild lockElectric failure compensationWireless remocon receiverMaster setting of indoor unitsΔT setting (For Auto Changeover)2 Controllers to 1 indoor units
On_Off / Fan speed / Mode / Temp.√√√√√
Weekly / Simple√√
Max. 2 hours√
MULTI V SYNC II
Optional function Plasma / Heater / HumidifierOperating air volume
: Applicable for only MULTI V II SERIES
PZRCUSB0
: Applicable for only MULTI V II SERIES
LG A
ir Conditioners System
76_
77
AC Smart & 128 Unit Expansion KitFor the mid sized buildings up to 64 or 128 indoor units can be controlled and monitored by touch screen central controller. It’s possible to control and monitor the air conditioning system through web access, anywhere with computer.
Function Controller & SchedulerIt is possible to control, monitor and schedule the operation of indoor units by using these controllerin company with a simple central controller
PQCSB101S0
Simple Central Controller• A central controller for managing small sites• Control up to 16 indoor units
Max. no of indoor units
Individual control
Lock function
Mode change
Malfunction indicator
Dimension(mm)
Power(V)
16 indoor units
On_Off Control
Total / Individual
Cooling / Heating
LED lamp
120 x 120 x 20
DC 10V
Features PQCSB101S0
& Accessory
* 1 Function controller combined with max. 8 simple central contollers.
Features PQCSB101S0+PQCSC101S0
16 indoor units
On_Off / Fan speed / Mode / Temp.
Total / Individual
Cooling / Heating / Fan
Error display on LCD
Weekly
(120x120x20)+(120x133x20)
DC 10V
16 indoor units
On_Off / Fan speed / Mode / Temp.
Total / Individual
Cooling / Heating / Fan
Error display on LCD
-
(120x120x20)+(70x120x14)
DC 10V
Max. no of indoor units
Individual control
Lock function
Mode change
Malfunction indicator
Schedule
Dimension(mm)
Power(V)
PQCSB101S0+PQCSD130A0
PQCSB101S0PQCSD130A0
*128 Indoor unit Expansion Kit: PQCSE440U0*DO Kit : PQNFP00T0
PI485
PQCSE440U0
Single constant
Eco-V
Single A, MULTI
MULTI V PLUS IIMULTI V SYNC IIMULTI V SPACE IIMULTI V MINI
MULTI V PLUSMULTI V SYNCMULTI V SPACE
LG A
ir Conditioners System
78_
79 &
Accessory
ACP (Advanced Control Platform)
PQCPA11A0E (Without IO)PQCPB11A0E (With IO)
• Through embedded web control function in ACP one can control and monitor various functions of air-conditioner such as temperature setting, schedule, peak power control, etc.
• Features
Application
Multi Area ManagementThe product specially designed for multi area management.-Central control & monitor Max. 4,096 indoor units & Max.16 ACP
Max. 4,096 Indoor
ACP AC ManagerKorean reference site.
ACP&AC Manager• AC Manager is suitable for large site because AC Manager is the S/W that can control Max. 16 ACP (Max.4,096 indoor units).
PQCPA11A0E (Without IO)PQCPB11A0E (With IO)
PQCSS520A0E (AC Manager)
PQCPA(B)11A0E
Max.no. of indoor units
Control / Monitoring
Schedule management
Lock function
Temperature range restriction
Temperature limit function
Auto Changeover function
History function
Peak control
PDI monitoring
Interlocking function
Printing function
256 indoor units
√
√
Temperature
-
-
-
Monitoring
√
Need of PDI
-
-
4,096 indoor units(16 ACP)
√
√
Mode/Temp/Fan speed/Schedule
√
√
√
Monitoring & Error history
√
Need of PDI
-
System setting, History, PDI
4,096 indoor units(16 ACP)
√
√
Mode/Temp/Fan speed/Schedule
√
√
√
Monitoring & Error history
√
Need of PDI
Fire sensor, Door sensor, Motion sensor...
System setting, History, PDI
PQCPA11A0E+PQCSS520A0E PQCPB11A0E+PQCSS520A0E
ACP ACP (without IO) + AC Manager ACP (with IO) + AC Manager
MULTI V PLUS IIMULTI V SYNC IIMULTI V SPACE IIMULTI V MINI
MULTI V PLUSMULTI V SYNCMULTI V SPACE
HUB
RS4851.25mm2 X 2C
(shield)
LANPI485
PHNFP14A0
PI485
LG A
ir Conditioners System
80
_8
1 &
Accessory
• Combination
DO Kit• Do Kit is connected between ACP (AC Smart) and external devices. So ACP(AC Smart) can start and stop external devices such as light, pump, motor, etc.
PQNFP00T0
• Features - Accumulated total power consumption indicated - Accumulated / Current power consumption of each indoor units indicated - Accumulated power consumption by month indicated - Max connectable no. of indoor units : 48 indoor units - 1 PDI per 1 outdoor unit - Power failure-proof function : Data back up on EEPROM even if power turns off - Connectable to PC based central controller
- Simple connection with the remote metering system (RS485 approach)
• This device is an indicator for power consumption of the multi type air-conditioner used for common power line.
PQNUD1S00
or
* In the case of MULTI V II SERIES, don’t need PI 485
PI485
Power of LoadBUS _ A
BUS _ B
L N
Web Access - Remote Management - Error Report via E-mail
Operation Report-Operating Time, Percentage, History
Emergency Interlock-Forced Off
128 Indoor unitsExpansion Kit
Multiple Local Controllers-Master / Slave
Multi Language-English, Italian, Spanish, French, German, Dutch, Russian
Easy Control-Function Lock-Lock Schedule
Comfort Control-Automatic H/C Changeover-Temperature Limit-Temperature Range Restriction-Time Limit Control
AC Smart• 7" Touch Screen / GUI
• Direct Connect to LGAP
DO Kit
• Remote Controller Restriction• Automatic Setting• A/C and Vent.
Easy Software Upgrade by USB
DI RS485
USB
Screen Saver
EmergencyLGAP
Light Pump Motor etc
Cooling
Heating
ACP or AC Smart
LG A
ir Conditioners System
82_
83
• Features - Through embedded web control function in BACnet one can access the airconditioner and external devices through internet. - It can control 256 indoor units. ( A/C or Ventilator ) - External devices such as fire alarm, motion detector can be connected to gateway and their function can be interlinked with airconditioner operation.
• Combination
& Accessory
PQNFB17B0
BNU-BAC Gateway (Building Network Unit- BACnet)
Easy interface between BMS and LG air conditioner- Independence of BMS under the standard BMS : Operation system based on BACnet Service.
Controlling Monitoring items
On/Off command
Operation mode setting
Fan speed setting
Lock setting
Air flow setting
Set temp. setting
User mode setting (for only ventilator)
On/Off status report
Operation mode status report
Fan speed status report
Lock status report
Air flow status report
Current space temp. status report
Error status report
User mode status report(for only ventilator)
• Combination
• Features - Connection to using LONTALK protocol and LG Air-conditioner protocol
- Process ability • 64 units( including indoors and ventilators) • Valid address for each unit : 0x00 ~ 0x3F
- Self installation verification function using internet (Web server included) • Setting gateway • Diagnosis of communication status on LG Air-conditioner network
- Connection to remote total management system (LG system)
PQNFB16A1
BNU-LW Gateway (Building Network Unit- )
Easy interface between BMS and LG air conditioner- Independence of BMS under the standard BMS : Operation system based on LNS ( network service) - No network installation needed - Very widely applicable protocol( )
NetworkBMS system
PHNFP14A0
Lighting control
Other LON devicesIndoor unit : Max. 64 units (Air-conditioner & ventilation)Indoor address : 00 ~ 3F
MULTI V PLUS IIMULTI V SYNC IIMULTI V SPACE IIMULTI V MINI
MULTI V PLUSMULTI V SYNCMULTI V SPACE
Eco-V
Single A, MULTI
MULTI V PLUS IIMULTI V SYNC IIMULTI V SPACE IIMULTI V MINI
MULTI V PLUSMULTI V SYNCMULTI V SPACE
RS4851.25mm2 X 2C
(shield)
RS4851.25mm2 X 2C
(shield)
Mode Change
Heating
Fan Mode
Cooling
LG A
ir Conditioners System
84
_8
5
• Combination
& Accessory
• Features - Indoor unit control without central controller - Select operation mode : Cooling, Heating, Fan mode - Mode lock for cooling & heating mixing error-proof during the change of season.
Cool/Heat SelectorThis switch enables selection of heating, cooling or fan mode. So it can prevent that cooling & heating mixing error occurs during the change of season.
PRDSBM
* PRDSBM is applicable for only MULTI V II Series.
Fresh air can be supplied from outside through this ventilation kit.
PTVK410 PTVK420 PTVK430
Ventilation Kit (4Way Cassette)
• Accessory• Installation Bracket• Bolt• Screw
• Dimension
• Models applied to
• Wiring diagram 1. Wire to the control box in the indoor unit by removing the existing thermistor and connect the extension cable its place. 2. Cut the extension cable to the appropriate length and connect the screw terminal of the remote sensor. 3. In the case of wired remote controller installed, set the temperature sensing slide s/w at MAIN mode.
Connector
Remote temperature sensor
Extension cable
Screw terminal connection
Indoor unit
Remote Temperature SensorIt can help to detect the exact room temperature at the optimal position.
• Model applied to Cassette, Duct type.• Part supplied - Remote temperature sensor - Cable (15m) - ManualPQRSTA0
PQDSB(A) / PQDSB1 / PQDSBC
Dry Contact module• It is connected between indoor units and external device, so it can be used for various purpose.
* PQDSBC is applicable for only MULTI V II Series.
• Features
√
√
√
√
√
√
√
√
√
√
Contact point
PQDSA(B) PQDSB1 PQDSBC
Voltage / Non voltage input
On_Off control
Lock / Unlock
Fan speed setting
Thermo off
Energy saving
Expected temperature setting
Error Monitoring
Operation monitoring
Power input
1 contact point
AC 220V from outside power source
√
√
√
1 contact point
AC 24V from outside power source
2 contact points
DC 5V&12V from indoor unit PCB
√
√
• Ceiling Cassette - 4Way (24k ~ 48k Btu/h)
LG A
ir Conditioners System
86
_8
7 &
Accessory
Refrigerant Charging Kit
PRAC1
• Procedure 1. Arrange manifold, refrigerant charging kit, refrigerant vessel and scale 2. Connect manifold to the gas pipe service valve of outdoor uint as shown in the figure. 3. Connect manifold refrigerant charging kit. Use designated refrigerant charging kit. If designated refrigerant charging kit isn’t used, the system may get damaged. 4. Connect refrigerant charging kit and refrigerant vessel. 5. Purge hose and manifold. 6. After “568” is displayed, open the valve and charge the refrigerant
• Error contents about auto refrigerant charging function
1. “329”: Temperature range error (In case that indoor unit or outdoor unit is out of range) 2. “339”: Low pressure descent error (In case the system runs at low pressure limit for over 10 minutes) 3. “349”: Rapid refrigerant inflow (In case the liquid refrigerant flows in because of not using designated refrigerant charging kit) 4. “359”: Instability error (In case the high/low pressure target doesn’t get satisfied for some time after the starting operation)
• Application • Dimension
133
69
202Manifold
Refrigerant
Refrigerant Charging Kit
AHU Control Kit & EEV KitFresh air can be supplied from outside connecting AHU to Multi V Plus II.
PRCKA0 PRLK048A0
• Specifications
Control KitEEV Kit
NETPOWERModel Name
Gross W H D
Weight(kg) Dimension(mm)
PRCKA0PRLK048A0
2.233.1
3.63.6
280404.2
13583
280217
220~240V / 50HZ / 1Pha
When selecting evaporator, Change ‘Option PCB’ in EEV kit according to below table(Basic ‘Option PCB is for 36k Btu/h )
• Selection of evaporator
Option PCB P/No Capacity (Btu/h)
Allowed heat exchanger Volume (dm3/hr)
Allowed heat exchanger capacity (kW)
EBR52358907
EBR52358908
EBR52358909
EBR52358910
EBR52358911
EBR52358912
28k
36k
42k
48k
76k
96k
1.22~1.53
1.53~1.91
1.91~2.14
2.14~2.67
3.06~3.82
3.82~4.78
7~9
9~11
11~13
13~16
20~24
25~31
* Saturated Suction Temperature (SST) = 6ºC, SH (Superheat)=5k, Air Temperature = 27ºC DB / 19ºC WB
(Main PCB)
Detail
Capacity setting'Option PCB'
• Wiring diagram
Single
Pipe
Themistor Return Air
Supply Air
(PRAC1)
LG A
ir Conditioners System
88
_8
9
Indoor unit
Outdoor unit
2
26
26
19
801x218x617
9.52(3/8)
19.05(3/4)
19.05(3/4)
Max. connectable number of indoor units
Max. connectable capacity of indoor units (Per port/unit) kW
Nominal Input cooling W
heating W
Net weight kg
Dimensions (WxHxD) mm
Piping Indoor liquid mm(inch)
connections unit gas mm(inch)
Outdoor liquid mm(inch)
unit low pressure mm(inch)
high Pressure mm(inch)
Power supply Ø/V/Hz
3
40
40
20
801x218x617
12.7(1/2)
28.58(1 1/8)
22.2(7/8)
4
40
40
21
801x218x617
12.7(1/2)
28.58(1 1/8)
22.2(7/8)
9.52(3/8)15.88(5/8)
1/220 ~ 240/50
PRHR020 PRHR030 PRHR040
14.1 / 47
• Specifications
PRHR020(2 Pipe-connection)
PRHR030(3 Pipe-connection)
• Combination
& Accessory
Heat recovery unit (Applied to MULTI V SYNC II R410A)
• Max. 4 indoor units can be connected by module design.
• Due to the automatic search algorithm for piping detection, easy installation and effectiveness is improved.
• Subcooling cycle in HR unit makes the system efficiency maximum.
PRHR040(4 Pipe-connection)
• Application • Dimension
• Features - High external static pressure facilitates unit use with flexible ducts of varying lengths. - When using suction panel, unit requires only 270mm of ceiling space. - Blends unobtrusively with any interior decoration.
PBSGB30
PBSGB40
A B C
910
1188
359
359
56
56
PBSC30
PBSC40
A B C
821
1100
274
274
42~250
42~250
• Models applied to - Ceiling concealed duct _ Built-in type
Type
√
√
Capacity (Btu/h)
7kModel
Grille
Canvas
PBSGB30PBSGB40
PBSC30PBSC40
√
√
√
√√
√
√
√
9k 12k 15k 18k 24k
√
√
C
A
B A
B
C
PQAGA
Air Guide• Used to control the direction of air discharge by outdoor unit.
• Converts vertical discharge into horizontal discharge.
• Dimension
Suction Grille and Canvas• High flexibility for a wide variety of applications
PBSGB30 / PBSGB40PBSC30 / PBSC40
If you need a highly efficient air condition-ing system in your building, MULTI V is the right choice for you.
Auto Clean
4-Way Air Deflection
Swirl Swing
Auto Restart
Sleep Mode Auto Operation
Weekly Program Wired remote controller only
Two Thermistor Control Wired remote controller only
Changable Panel
Second Remote Control
NEO Plasma Air Purifying System
Jet Cool
Child Lock Function Wired remote controller only
Healthy Dehumidification
Hot Start (Heat pump only)
Soft Dry Operation Mode
Low Standby Power
Group Control Wired remote controller only
Auto Changeover MULTI V SYNC model only
( )
( )
( )
( )
( )
LG A
ir Conditioners System
90
_9
1 &
Accessory
* MULTI V PLUS II, MULTI V MINI, MULTI V SPACE II
Model ModelGas Pipe Liquid Pipe Gas Pipe Liquid Pipe
(unit:mm) (unit:mm)
ARBLN07121
ARBLN14521
* MULTI V SYNC II
Model Low Pressure Gas Pipe Liquid Pipe
(unit:mm)
ARBLB01621
High Pressure Gas Pipe
ARBLB03321
ARBLB07121
ARBLB14521
Y Branch pipe for connection of indoor units
ARBLN01621
ARBLN03321
* MULTI V SYNC II (2 Outdoor units)
Model Low Pressure Gas Pipe
Liquid Pipe
(unit:mm)
ARCNB20
High Pressure Gas Pipe
* MULTI V SYNC II (3 Outdoor units)
Model Low Pressure Gas Pipe
Liquid Pipe
(unit:mm)
ARCNB20
High Pressure Gas Pipe
ARCNB30
Header for connection of indoor units
Y Branch pipe for connection of outdoor units
Model
4 branchARBL054
7 branchARBL057
4 branchARBL104
Model
7 branchARBL107
10 branchARBL1010
10 branchARBL2010
Gas Pipe Liquid Pipe Gas Pipe Liquid Pipe
(unit:mm) (unit:mm)
* MULTI V PLUS II (2 Outdoor units)
Model
ARCNN20
Model
ARCNN20
ARCNN30
Connection of Gas Pipe Connection of Liquid Pipe Connection of Gas Pipe Connection of Liquid Pipe